observation and no later than one year of the date A. O. Smith manu- factured the
..... Find your pump brand, listed in alphabetical order at the right. .... Pump rated
for 115/230 Volt, check voltage supply to ensure replacement motor is suitable.
Group S ..... Centurion® SE “1081” • Up Rate • Low Service Factor. 3/4. 3450.
Pump Motors for Swimming Pools, Spas & Jetted Tubs Bulletin 1081/1082 Includes and identifies California California Energy Commission Compliant Motors
Formerly Formerly A. A. O. O. Smith Smith Publications Publications #1081 #1081 && #1082 #1082
A Deeper Pool of Resources
Statement of Warranty Policy All motors of A. O. Smith carry warranties. The nature and length of the warranty will depend upon the motor and are set forth below. Partial Motors. Partial motors are warranted against defect in materials and workmanship observed prior to any assembly of the motor parts by the Purchaser, provided that such claim is made within 30 days of its observation and no later than one year of the date A. O. Smith manufactured the partial motor. The company makes no warranty and disclaims all warranties as to latent defects. Pool Motors. Pool motors are warranted to be free of defects in workmanship and materials for a period of 24 months from the date of installation or 36 months from the date of manufacture. Whichever comes first. These motors must have the A. O. Smith two-compartment design or must be the 1081 designated ‘Centurion’ brand. Effective with motors manufactured in August 2004 and later, the warranty policy on motors will change to: Pool motors are warranted to be free of defects in workmanship and materials for a period of 12 months from the date of installation. If the customer does not have proof of date of installation, the warranty shall expire 24 months from the date of manufacture. Speed Engineered motors carry a two-year warranty from the date of manufacture and a one year warranty from date of installation.
Pool Motor Serial Number Introduction of a new standard date code was implemented in August of 2006 that will eventually be used on all A. O. Smith product. The first three characters represent the day of the year, the next two the year, and the last two the plant code. For example, 12306M, would mean the 123rd day of 2006 (12306) manufactured in A. O. Smith’s plant (4M). The first space is the plant code. The second letter is the month. And, the third and fourth spaces are the year. Example: “8A05” = Plant 8, January 2005 A. O. Smith Serial Number (Date Codes): 2000 is “00” G = July 2001 is “01” H = August 2002 is “02” I = September 2003 is “03” J = October 2004 is “04” K = November 2005 is “05” L = December A = January B = February C = March D = April E = May F = June
E-Plus motors carry a two-year warranty from the date of manufacture or one year from the date of installation. E-Plus 3 motors carry a three-year warranty from the date of manufacture or a two year warranty from the date of installation. All other A. O. Smith motors in this catalog are warranted to be free of defects in workmanship and materials for a period of 12 months from the date of installation. If the customer does not have proof of the date of installation, the warranty shall expire 24 months from the date of manufacture. This warranty is limited and shall be in lieu of any other warranties, expressed or implied, including but not limited to, any implied warranty or merchantability or fitness for a particular purpose. There are no other warranties that extend beyond the description of the face hereof. The liability of the Company arising out of its supply of said products, or their use, shall not in any case exceed the cost of correcting defects in the products as above set forth. The Company shall not be liable for any costs or damage incurred by its customers in the removal or replacement of defective products from units in which the products have been assembled. In no event shall the company be liable for loss of profits, indirect, consequential or incidental damages. This warranty does not apply if the failure is caused or contributed to by any of the following: improper handling, improper storage, improper installation, abuse, unsuitable application of the product, lack of reasonable and necessary maintenance, improper packaging for return, or repairs made or attempted by any other company, which in the judgement of the Company adversely affects the product’s performance or reliability. No products shall be returned to the Company without its prior consent and shall be properly packaged and shipped prepaid Point of Shipment, to the Company’s Authorized Service Center. The Company cannot assume responsibility or accept invoices for unauthorized repairs to its components, even though the motors may be defective. A. O. Smith reserves the right to change its warranty any time, effective as to motors changed after that date.
“CENTURY - CENTURION” The first two letters are “Year”; followed by number for month; and plant. Example: Ser: CA01-08 = 2005 January, Plant 8 Century Serial # (Date Code): 2000 = “BU” 2005 = “CA” 2001 = “BW” 2006 = “CB” 2002 = “BX” 2007 = “CC” 2003 = “BY” 2008 = “CD” 2004 = “BZ” 2009 = “CE” 01 - January 02 = February 03 = March 04 = April 05 = May 06 = June
07 = July 08 = August 09 = September 10 = October 11 = November 12 = December
Claims for After-market Replacement Motors go to: A. O. Smith Electrical Products Company Distribution Services Warranty at Dept. N-10 531 North Fourth Street Tipp City, OH 45371 OEM’s warranty their own products: Jacuzzi, Goulds, Hayward, Pentair/Purex, Polaris, Sta-Rite Please submit OEM warranty claims to the respective Original Equipment Manufacturer.
Contents Centurion Motor Replacement Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 Two Compartment Motor Replacement Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Two Compartment – C-Face Pool Filter Motors . . . . . . . . . . . . . . . . . . . . . . . . . . .5-7 Centurion – C-Face Pool Filter Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9 Two Compartment – Square Flange Pool Filter Motors . . . . . . . . . . . . . . . . . . .10-11 Centurion – Square Flange Pool Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-13 Above Ground – Pool, Flex 48 & Spa Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Two Compartment – Pool Sweep Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Sta-Rite Direct Replacement Spa Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Century – Three-Phase Swimming Pool Pump Motors . . . . . . . . . . . . . . . . . . . . . .16 Century – Pool Cleaner Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Century – Purex Direct Replacement Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Centurion – Three Phase Square Flange Pool & Spa Motors . . . . . . . . . . . . . . . . . .17 Century – Pentair/Pac Fab Direct Replacement Motors . . . . . . . . . . . . . . . . . . . . . .17 Century – Waterway Direct Replacement Motors . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Century – Hayward Northstar Direct Replacement Motors . . . . . . . . . . . . . . . . . . .18 Century – Close-Coupled Pump Motors: Three Phase Dripproof Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Three Phase Dripproof Rigid Base Motors . . . . . . . . . . . . . . . . . . . . . . . . .20 Three Phase Dripproof NEMA C-Face Motors . . . . . . . . . . . . . . . . . . . . . .20 Three Phase TEFC Rigid Base Motors . . . . . . . . . . . . . . . . . . . . . . . . . .21-22 Single Phase Dripproof Rigid Base Motors . . . . . . . . . . . . . . . . . . . . . . . . .23 Commercial Pump Motor Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Energy Savings Estimator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Inside Back Cover
Motor Efficiency
(Do not confuse amp draw with motor efficiency) Output Watts divided by Input Watts = Motor Efficiency When comparing motors of different configurations (ex: Permanent Split Capacitor to Capacitor Start-Capacitor Run) lower amps do not mean higher efficiency. Efficiency of the motor is determined as follows: Output Watts are defined as: 746 Watts equals 1 H.P. Multiply the nameplate H.P. times the nameplate Service Factor times 746 Watts to determine the maximum Output Watts. Contact the motor manufacturer for Input Watts. You'll need to supply the motor model number. Use the above formula to determine efficiency. Total efficiency of the system will also depend on pump efficiency and quality of the installation.
www.aosmithmotors.com
Cost to Operate
(Do not confuse amp draw with cost to operate) The formula to calculate the cost to operate an AC Single-phase Motor is: Cost = Volts x Amps x Power Factor x Rate x Usage 1000 Power Factor: Contact the motor manufacturer. You will need to supply the motor model number. Rate: Local utility charge per kilowatt hour. Usage: Hours motor is running (can be per day, per month or per year)
1
Centurion Pool & Spa Square Flange & C-face Replacement Guide Before using the Pool & Spa Motor Replacement Guide, you will need to know the horsepower (1), the service factor (2) of the original motor, and the name and/or the manufacturer of the pump on which the motor is used. The sample nameplate below shows the location of the horsepower and service factor.
Name of Pump OEM or Brand Name Group Americana, American Eagle . . . . . . . . . . . . . . . . . . . . . . . . . . A American Ultra-flow or Power Pump . . . . . . . . . . . . . . . . . . . . C Aqua Flo C-face . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Aqua Flo Dominator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A,B,C Arneson Pool Sweep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D Hayward Northstar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E Baker Hydro Hydron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Hayward Super Pump or Super Pump II . . . . . . . . . . . . . . . . . A Hayward Max-Flo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A ITT Marlow Argonaut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Jacuzzi Bros. Bronze . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Jacuzzi Bros. Cygnet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Jacuzzi Bros. Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Jacuzzi Bros. Magnum (E-Plus® columns only) . . . . . . . . . . . A Letro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D Pac Fab Challenger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Pac Fab Hydro Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Pac Fab Pinnacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Polaris Vac-Sweep PB4 Booster Pump . . . . . . . . . . . . . . . . . . D Premier/Springwater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Purex/ Hydrotech . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Purex Whisperflo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Sta-Rite Dura-Glas or Max-E-Glas . . . . . . . . . . . . . . . . . . . . . C Sta-Rite Dura-Glas II or Max-E-Glas II . . . . . . . . . . . . . . . . . . .C Speck Pumps, Models 90, 98, 423, 433, 21-80 . . . . . . . . . . . A Wet Institute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Two-speed and three-phase motors available for most applications. Contact your distributor or A. O. Smith Electrical Products Company for more details.
1
CE7-28
2 Find your pump brand, listed in alphabetical order at the right. Read across from the pump name and find the group of Century® catalog motors that will mechanically fit. These groups are labeled “A” through “E”. The service factor for each horsepower is shown in these groups below. Match the manufacturer of the pump, the horsepower, and the service factor and you will have a suitable replacement motor.
Group “A” C-face Threaded Shaft (56J) (Page 3-5)
Hp
1⁄ 3⁄2 4 1 11⁄2 2
21⁄2 3 4
Service Factor
Voltage
Centurion® Standard Efficiency Alum. Cat. No.
1.60 1.00 1.50 1.00 1.40 1.00 1.30 1.00 1.20 1.20 1.00 1.15 1.25
230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230 230 230 230
B126 B227SE B127 B228SE B128 B229SE B129 B230SE B836 B130 B231SE B131 —
E-Plus® Energy Efficient Alum. Cat. No.
B657 B657 B638 B638 B654 B654 B796 B796 — B809 B809 B818 B116
Group “C” Square Flange (Page 6-7) Neptune® Service Hp Factor
1⁄ 3 1⁄ 2 3⁄ 4 1 11⁄2
2 21⁄2 3
1.95 1.30 1.95 1.25 1.65 1.25 1.65 1.10 1.50 1.50 1.10 1.30 1.04 1.15
Group “B” C-face Keyed Shaft (56C) (Page 3-5)
Hp
1⁄ 2 3⁄ 4 1 1 1 ⁄2 2 3
2
Service Factor
1.60 1.50 1.40 1.30 1.20 1.20 1.15
Centurion® Standard Efficiency Alum. Voltage Cat. No.
230/115 230/115 230/115 230/115 230/115 230 230
B120 B121 B122 B123 B835 B124 B125
Voltage
230/115 23˜0/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230 230 230 230 208-230
Centurion® Standard E-Plus® Efficiency Energy Efficient Cat. No. Cat. No.
— B856 B846 B852 B847 B853 B848 B854 B858 B849 B855 B748 B840 ––
— — B845 — B661 — B841 — –– B842 — B843 — B844
Group “E” Northstar Hayward (Page 10)
Neptune® Standard Energy Efficiency EfficientService Hp Factor Cat. No. Cat. No.Voltage
3⁄ B879 4 1 B882 1 B880 1⁄ 1-B885 2 1⁄ 1-B881 2 2 B886 2 B883 3 B887 3— — — — — —
1.85 1.40 1.85 1.25 1.60 1.20 1.35 1.20 1.60
—208-230/115 —208-230/115 208-230/115 B872 208-230/115 B872 208-230/115 B873 208-230/115 B873 B874208-230 B874208-230 — 208-230
Cat. No.
SN1072 USN1102 SN1102 USN1152 SN1152 USN1202 SN1202 USN1302 SN1302
B875 B876 B877 B884 B878
Group “D” Pool Cleaner Replacement (Page 9) E-Plus® Energy Efficient Alum. Cast Iron Cat. No. Cat. No.
B656 B634 B653 B795 –– B808 B817
–– B631 B723 B750 –– B772 B774
Hp
3⁄ 4
Service Factor
Voltage
Shaft
Brand
Cat. No.
1.50 1.50 1.50 1.50 1.50
230/115 230/115 230/115 230/115 230/115
Threaded Threaded Threaded Threaded Threaded
Polaris Arneson Uniseal Arneson Uniseal Letro Letro
B625 B662 B663 B667 B668
www.aosmithmotors.com
Pool, Spa and Jetted Tubs Thru-Bolt Motor Replacement Guide To select the correct thru-bolt replacement motor, complete steps 1 through 4. 1.
2.
Is the manufacturer and model of your pump in the list of pump manufacturers and models below? If yes, the Century® motors from Group S and Group T in the tables below will fit your pump. Identify the maximum rated horsepower of your motor. Maximum Rated Hp = Horsepower (Hp) x Service Factor (SF)
Group S Single-speed (see page 8) Hp (Max. Rated)
Voltage
1⁄ 2 3⁄ 4 1 1 1 ⁄2 2
115 115 115 230/115 230/115
Pump Manufacturer & Model
Hp
Threads
Rotation
BV90
1.0
Right Hand
CW
BV91
1.0
Left Hand
CCW
3.
What is the voltage?
4.
Is the motor single- or two-speed? If single-speed select motor from Group S. If two-speed, select motor from Group T.
Group T Two-speed (see page 8) Cat. No. BN23SS BN24SS BN25SS BN35SS BN40SS
Group
American Products American II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Maxim “C” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Maxim “S” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Aqua Flo Flo-Master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Tub Master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S G/G Industries Olympian . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Gruber Dura-Flo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Hayward Mfg. Power Flo 1500 Series . . . . . . . . . . . . . . . . . . . . . . . . . S Power Flo II 1700 Series . . . . . . . . . . . . . . . . . . . . . . . . S Power Flo II 1900 Series . . . . . . . . . . . . . . . . . . . . . . . . S Power Flo UN Series . . . . . . . . . . . . . . . . . . . . . . . S or T Power Flo UN-LX Series . . . . . . . . . . . . . . . . . . . . S or T Power Flo II UN Series . . . . . . . . . . . . . . . . . . . . . . . . . T Power Flo 1900SD Series . . . . . . . . . . . . . . . . . . . . . . . S Hoffinger, Doughboy and Lomart Cat. No.
Replacement motor horsepower must be equal to or greater than maximum rated horsepower.
Replaces Hoffinger #
300-1028 (1 Hp) 300-1027 (3⁄4 Hp) 300-1043 (1 Hp) 300-1017 (3⁄4 Hp)
Jacuzzi Bros. Inno-Tech J Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . S JCM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Vector LVL Series* . . . . . . . . . . . . . . . . . . . . . . . . . . . . S
Hp (Max. Rated)
Voltage
Cat. No.
3⁄ /.10 4 1/.12 1/.16 11⁄2/.25 11⁄2/.18 11⁄2/.18 2 /.25 2 /.25
115 115 115 115 115 230 230 230
BN36 BN37 BN38 BN50 BN60 BN34 BN51 BN61
Pump Manufacturer & Model
Group
Jacuzzi Bros. (continued) LTVL Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T SLR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S LRDV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S LCU Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T LTCU Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T LCM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S LTCM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T PAC-FAB Dynamo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Dynamite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Premier/Springwater 220-225-255 MKii Series . . . . . . . . . . . . . . . . . . . S or T 300, 320, 325, 355 Series . . . . . . . . . . . . . . . . . . . . . . S Speck Model E90 and E91 . . . . . . . . . . . . . . . . . . . . . . . S or T Sta-Rite Dura-Jet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Vico/Ultra-Jet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Ultra Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Waterway Bath Pump Self Drain . . . . . . . . . . . . . . . . . . . . . . . . . . S Hi-Flo Side Discharge . . . . . . . . . . . . . . . . . . . . . . S or T Hi-Flo Center Discharge . . . . . . . . . . . . . . . . . . . . S or T SVL56 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C Super Flo Side Discharge . . . . . . . . . . . . . . . . . . .S or T Workhorse Side Discharge . . . . . . . . . . . . . . . . . . .S or T
Note: * Pump rated for 115/230 Volt, check voltage supply to ensure replacement motor is suitable.
www.aosmithmotors.com
3
A.O. Smith Two Compartment to Motor Replacement Guide Name of Pump OEM or Brand Name Group Class Americana, American Eagle . . . . . . . . . . . . . . . . . . . . . ST American Ultra Flow or Power Pump . . . . . . . . . . . . . .SQ Aqua-Flo C-Face . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SK Aqua-Flo Dominator . . . . . . . . . . . . . . . . . . . . . . . . . . .SQ Arneson Pool Sweep . . . . . . . . . . . . . . . . . . . . . . . . . .SP Hayward Super & Super II . . . . . . . . . . . . . . . . . . . . . .ST Hayward Max-Flo . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ST Hydrotech . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ST ITT Marlow Argonaut . . . . . . . . . . . . . . . . . . . . . . . . . .ST Jacuzzi Bronze, Plastic . . . . . . . . . . . . . . . . . . . . . . . . .SK Jacuzzi Magnum . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ST Pac Fab Challenger . . . . . . . . . . . . . . . . . . . . . . . . . . .SQ Pac Fab Hydro Pump . . . . . . . . . . . . . . . . . . . . . . . . . .SK Premier/Springwater . . . . . . . . . . . . . . . . . . . . . . . . . . .SK Starite Duraglas or Maxiglas . . . . . . . . . . . . . . . . . . . . .SQ Speck . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ST Wet Institute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SK
Group “SK”
Group “SQ”
Group “ST”
Hp
Service Factor
Voltage
Stock Number
1/2 1/2 3/4 3/4 1 1 1-1/2 1-1/2 2 2 2-1/2 3
1.9 1.3 1.65 1.27 1.65 1.25 1.47 1.1 1.3 1.1 1.0 1.15
115/230 115/230 115/230 115/230 115/230 115/230 208-230 115/230 230 208-230 230 230
SQ1052 USQ1052 SQ1072 USQ1072 SQ1102 USQ1102 SQ1152 USQ1152 SQ1202 USQ1202 USQ1252 SQ1302
Hp
Service Factor
Voltage
Stock Number
Conservationist
1/2 3/4 1 1.5 2 3
1.6 1.5 1.5 1.3 1.3 1.115
115/230 115/230 115/230 115/230 230 230
SK1052 SK1072 SK1102 SK1152 SK1202 SK1302
CK1052 CK1072 CK1102 SK1152 SK1202 SK1302
Group “SP” Hp
Voltage
Brand
Stock Number
3/4 3/4
115/230 115/230
Arneson Arneson
SPS1052 RPS1052
Conservationist
Hp
Service Factor
Voltage
Stock Number
QC1052
1/2 3/4 3/4 1 1 1-1/2 1-1/2 2 2 2-1/2 3
1.6 1.5 1.0 1.5 1.0 1.3 1.0 1.3 1.0 1.0 1.15
115/230 115/230 115/230 115/230 115/230 115/230 115/230 230 115/230 230 230
ST1052 ST1072 UST1072 ST1102 UST1102 ST1152 UST1152 ST1202 UST1202 UST1252 ST1302
QC1072 UQC1072 QC1102 UQC1102 SQ1152 UQC1152 SQ1202 USQ1202 USQ1252 SQ1302
Above Ground and Spa Applications Hp
Service Factor
Voltage
Stock Number
1/2 3/4•1/8 3/4 1•1/6 1
1.0 1.0 1.0 1.0 1.0
115 115 115 115 115
BN23SS BN36* BN24SS BN37* BN25SS
Conservationist
CT1052 CT1072 CT1012 ST1152 ST1202
ST1302
Please Note: Every effort has been made to ensure the accuracy of this guide. A.O. Smith cannot, however, accept responsibility for ultimate selection. OEM design changes and variations from one OEM to another may result in different construction, dimensions or operating characteristics. It is your responsibility to confirm the acceptability of the suggested replacement.
Notes: *2 Speed Please contact your local distributor with motor model number, frame size, horsepower, service factor, voltage and pump OEM model number for proper spa or above ground motor identification.
4
www.aosmithmotors.com
Two Compartment NEMA C-Face Pool Filter Motors • Single Speed Important: Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced
Features
Features: • Auto Protector • Capacitor Start and Capacitor StartImportant: Run Total •output (HP x service of replacement motor must equal or exceed motor being replaced Capacitor NEMA “56C” Facefactor) Mount • Not Reversible • Open Drip Proof • Rotation (CCWPE) • Sealed Ball Bearings •• Sealed Switch Design • •“1081” Design • 50° C Ambient • 60 HZ All Copper Not Reversible • “1081” Design • 303 Stainless Shaft (56J &• 56C) 304Proof Brg. Shaft End Windings Open•Drip • 50° C Ambient • Auto Protector • Capacitor Start • NEMA “56C” Face Mount
• Rotation (CCWPE) • Sealed Ball Bearings • Sealed Switch Design
• 60 HZ • 303 Stainless Shaft (56J & 56C) • 304 Brg. Shaft End
CT1072
SK1072
HIGH SERVICE FACTOR (FULL RATED)- STANDARD EFFICIENCY AND “CONSERVATIONIST” HIGH EFFICIENCY DESIGNS HP
RPM
Volts
Max. Amps
Service Factor
Frame
Stock Number
Shaft
Approx. “AG”
1/2
3450
115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/208-230 230 208-230 230 208-230
10.6/5.3 8.0/4.0 11.0/5.5 8.0/4.0 14.6/7.3 11.0/5.5 15.0/7.5 11.0/5.5 17.0/8.5 13.6/6.8 18.6/9.3 18.6/9.3 13.6/6.8 19.4/9.7 19.6/10.4-9.8 11.2 12.6-11.4 14.4 14.5-13.8
1.6 1.6 1.6 1.6 1.5 1.5 1.5 1.5 1.5 1.4 1.5 1.5 1.4 1.3 1.5 1.3 1.3 1.15 1.15
56C 56C 56J 56J 56C 56C 56J 56J 56C 56C 56J 56J 56J 56C 56J 56C 56J 56C 56J
SK1052 CK1052 ★ ST1052 CT1052 ★ SK1072 CK1072 ▲ ST1072 CT1072 ▲ SK1102 CK1102 ▲ ST1102 STE1102 CT1102 ▲ SK1152 ▲ ST1152 ▲ SK1202 ▲ ST1202 ▲ SK1302 ▲ ST1302 ▲
Key Key Thd. Thd. Key Key Thd. Thd. Key Key Thd. Thd. Thd. Key Thd. Key Thd Key Thd.
11 11 10-5/8 11 11-9/16 11-11/16 11 11-11/16 12-1/8 12-1/8 12-1/8 12-1/8 12-1/8 12-5/8 12-5/8 13-1/16 13-1/16 13-5/8 14-3/16
3/4
1
3450
3450
1-1/2
3450
2
3450
3
3450
Notes 20
$
20
$
20
$
20
$
20
$
351 20 20 20 20 20 20 20
$ $ $ $ $ $ $
Notes: 20. $ Energy Efficient capacitor start, capacitor run “Conservationist” motor 351. eMod™ equipped motor See page 258 for mounting dimensions. eMod® motors on this page pass ASME A112.19.17 SVRS standard. eMod® will not prevent evisceration, hair, object or partial limb entrapment and is designed for suction lift applications. ▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov
www.aosmithmotors.com
5
Two Compartment NEMA C-Face Pool Filter Motors • Single Speed Important: Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced Features Features: • Auto Protector • Capacitor Start • NEMA “56C” Face Mount Total output (HP xDrip service factor) of replacement or exceed motor being replaced •Important: Not Reversible • Open Proof • Rotation (CCW motor Pumpmust End) equal • Sealed Ball Bearings • Sealed Switch Design • “1081” Design • 50° C Ambient • 60 HZ • 303 Stainless Shaft • • • •
All Copper Windings Auto Protector Capacitor Start NEMA “56C” Face Mount
• Not Reversible • Open Drip Proof • Rotation (CCW Pump End) • Sealed Ball Bearings
• Sealed Switch Design • “1081” Design • 50° C Ambient
• 60 HZ • 303 Stainless Shaft • 304 Brg. Shaft End
UST1072
LOW SERVICE FACTOR (UP-RATED) - STANDARD EFFICIENCY AND “CONSERVATIONIST” HIGH EFFICIENCY DESIGNS HP
RPM
Volts
Max. Amps
Service Factor
Frame
Stock Number
Shaft
Approx. “AG”
3/4
3450
115/230
11.0/5.5
1.0
56J
UST1072
Thd.
10-5/8
1
3450
1.0 1.1 1.1 1.0 1.0 1.0 1.0 1.1 1.1
56J 56J 56J 56J 56J 56J 56J 56J 56J
UCT1072 ★ UST1102 USTE1102 UCT1102 ▲ UST1152 USTE1152 UCT1152 ▲ UST1202 ▲ UST1252 ▲
Thd. Thd. Thd. Thd. Thd. Thd. Thd. Thd. Thd.
11 11 11 11-11/16 12-1/8 12-1/8 12-1/8 12-5/8 13-1/16
1-1/2
2 2-1/2
3450
3450 3450
115/230 8.0/4.0 115/230 15.0/7.5 115/230 15.0/7.5 115/230 11.0/5.5 115/230 18.6/9.3 115/230 18.6/9.3 115/230 14.6/7.3 115/208-230 19.6/10.4-9.8 208-230 12.6/11.4
Notes 20
$
351 20
$
351 20 20 20
$ $ $
Note: 20 $ Energy Efficient capacitor start, capacitor run “Conservationist” motor 351. eMod™ equipped motor eMod® motors on this page pass ASME A112.19.17 SVRS standard. eMod® will not prevent evisceration, hair, object or partial limb entrapment and is designed for suction lift applications. ▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov
6
www.aosmithmotors.com
Two Compartment NEMA C-Face Pool Filter Motors • Two Speed Important: Features Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced Features: Auto output Protector Capacitor Start • Stainless motor Steel Threaded Important: Total (HP •x service factor) of replacement must equalShaft or exceed motor being replaced • Not Reversible • Open Drip Proof • Rotation (CCW Pump End) • Sealed Ball Bearings (304 Shaft End) • Sealed Switch Design • “1081” Design •• Sealed 40° C Ambient • 60 • Auto Protector • Not Reversible Ball • HZ “1081” Design • Capacitor Start • Open Drip Proof Bearings (304 • 50° C Ambient A.O. Smith NEMA C flange swimming pool filter pump motors are carefully engineered to meet the rugged demands of pool duty. Two sealed ball bearings (with large 304 bearing on shaft end) offer ample capacity for extended life. Bearings are selected for quietness and are lubricated for life with greases specifically chosen for moisture and heat resistant qualities. Aluminum end frames are accurately machined for maximum concentricity and minimum runout.
STS1072R
Two-speed motors are shipped less hi/lo switch for remote operation. End cover and switch assembly kit number 615332 available and sold separately.
HP 3/4~1/8 1~1/6 1-1/2~1/4 2~1/3
RPM 3450/1725 3450/1725 3450/1725 3450/1725
Volts 230 230 230 230
Max. Amps Hi - Lo 6.4/1.9 8.5/2.5 9.0/3.3 11.4/4.1
Service Factor 1.5 1.5 1.3 1.2
Frame 56J 56J 56J 56J
Stock Number STS1072R STS1102R STS1152R STS1202R
★ ★ ★ ★
Shaft Thrd Thrd Thrd Thrd
Approx. “AG” 12-1/8 13-1/16 13-1/16 13-3/4
Notes 90 20 20
$ $ $ $
★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov
NEMA C-Face 3-Phase Pump Motors Features: Ball Bearings • Continuous Duty • Internal Junction Box • Keyed and Stainless Steel Threaded Shafts • NEMA “56C” Mount • Open Drip Proof • 40° C Ambient • 60 HZ • 208-230/460V T3052
NEMA C Face mounting bracket, and end frames are die-cast corrosion resistant aluminum, accurately machined for maximum concentricity, and minimum runout. Stator assemblies are press fitted into rolled steel main frames. Double shielded ball bearings, selected for quiet operation, are lubricated for life with greases specifically chosen for moisture and heat resistant qualities. 1/2" x 14 thread tapped opening is provided for conduit fitting. No external junction box required connections made under motor canopy. Motors are supplied with horizontal canopy but are easily converted for vertical operation with the use of optional vertical canopy (call Customer Service for more information). HP 1/2 3/4
RPM 3450 3450
1
3450
1-1/2
3450
2
3450
3
3450
Volts 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 230/460 230/460
Max. Amps 2.7/1.35 3.4/1.7 3.4/1.7 4.0/2.0 4.0/2.0 6.8/3.4 6.8/3.4 8.6/4.3 8.6/4.3 9.0/4.5 9.0/4.5
Service Factor 1.6 1.5 1.5 1.4 1.4 1.3 1.3 1.2 1.2 1.15 1.15
Frame 56J 56C 56J 56C 56J 56C 56J 56C 56J 56C 56J
Stock Number T3052 K3072 T3072 K3102 T3102 K3152 T3152 K3202 T3202 K3302 T3302
Shaft Thrd Key Thrd Key Thrd Key Thrd Key Thrd Key Thrd
Protector None None None None None None None None None None None
Approx. “AG” 8-5/8 9-1/8 9-1/8 9-11/16 9-11/16 11-5/16 11-5/16 11-5/16 11-5/16 11-7/16 11-7/8
Notes
1 1
Notes: 1. Item to be discontinued when stock is depleted 20. $ Energy Efficient capacitor start, capacitor run “Conservationist” motor 90. 50 degree C ambient See page 258 for mounting dimensions.
www.aosmithmotors.com
7
Centurion® C-Face Pool and Spa Pump Motors Permanent Split Capacitor • Switchless • Single Phase • Dripproof • No Base • 3450 RPM 1/2 thru 4 HP B126
Features: Ball Bearing • 50°C Ambient • 60 Hz • Class B Insulated • Rotation (CCW Pump End) • 304 Bearing Shaft End
Centurion® “1081” • Full Rate • High Service Factor • Aluminum NEMA “C” Brackets HP
RPM
Volts
Service Factor Amps
1/2
3450
3/4
3450
1
3450
230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230 230/115 230 230 230 208-230
4.4/8.8 4.4/8.8 6.0/12.0 6.0/12.0 7.2/14.4 7.2/14.4 7.2/14.4 9.2/18.4 9.2/18.4 9.2/18.4 10.8/21.6 10.5 10.8/21.6 10.5 14.1 14.1 21.0-19.4
1-1/2
2
3450
3450
3
3450
4
3450
Service Factor
Frame
1.60 1.60 1.50 1.50 1.40 1.40 1.40 1.30 1.30 1.30 1.20 1.20 1.20 1.20 1.15 1.15 1.25
56C 56J 56C 56J 56C 56J 56J 56C 56J 56J 56C 56C 56J 56J 56C 56J 56Y
Stock Number
B120 ★ B126 ★ B121 ▲ B127 ▲ B122 ▲ B128 ▲ BE128 ▲ B123 ▲ B129 ▲ BE129 ▲ B835 ▲ B124 ▲ B836 ▲ B130 ▲ B125 ▲ B131 ▲ B116 ▲
Overload Protector
Shaft
"C" Dimension
Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Manual
Keyed Threaded Keyed Threaded Keyed Threaded Threaded Keyed Threaded Threaded Keyed Keyed Threaded Threaded Keyed Threaded Special
11.44 11.94 11.44 12.01 11.89 12.14 12.45 13.19 13.50 13.50 13.94 12.55 13.90 13.10 13.65 14.15 16.78
12 31,34,63,236
Overload Protector
Shaft
"C" Dimension
Notes
Notes
12 12 12 12,351 12 12,351
12 12
Centurion® SE “1081” • Up Rate • Low Service Factor HP
3/4 1 1-1/2 2 2-1/2
RPM
Volts
3450 3450 3450 3450 3450
230/115 230/115 230/115 230/115 230
Service Factor Amps
4.4/8.8 6.0/12.0 7.2/14.4 9.2/18.4 10.5
Service Factor
1.00 1.00 1.00 1.00 1.00
Frame
56J 56J 56J 56J 56J
Stock Number
B227SE ★ B228SE ▲ B229SE ▲ B230SE ▲ B231SE ▲
Auto Auto Auto Auto Auto
Notes:
Threaded Threaded Threaded Threaded Threaded
12.56 12.81 13.91 14.31 13.81
12 12 12 12 12
Continues on next page
12. 303 Stainless steel shaft 31. 40 degree C ambient 34. Rigid base 63. Speck Pump replacement motor 236. CCW Rotation facing opposite shaft end 351. eMod™ equipped motor eMod® motors on this page pass ASME A112.19.17 SVRS standard. eMod® will not prevent evisceration, hair, object or partial limb entrapment and is designed for suction lift applications. ▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov
8
www.aosmithmotors.com
Centurion® C-Face Pool and Spa Pump Motors
Continued from previous page
Permanent Split Capacitor • Switchless • Single Phase • Dripproof • No Base • 3600 & 3600/1800 RPM 1/2 thru 3 HP Features: Ball Bearing • 304 BRG Shaft End • 60 Hz • Class B Insulated • Rotation (CCW Pump End) • $ Energy Efficient
B971
E-Plus® Energy Efficient “1081” • Centurion® • Full Rate • Aluminum NEMA “C” Brackets • 50˚C Ambient HP
RPM
1/2
3450
3/4
3450
1
3450
1-1/2
3450
2
3450
3
3450
Service Factor Amps
Volts
208-230/115 208-230/115 208-230/115 208-230/115 208-230/115 208-230/115 208-230/115 208-230/115 208-230 208-230 208-230 208-230
4.0-3.7/7.4 4.0-3.7/7.4 5.4-5.0/10.0 5.4-5.0/10.0 6.4-5.9/11.8 6.4-5.9/11.8 8.7-7.8/15.6 8.7-7.8/15.6 10.4-9.6 10.4-9.6 15.0-13.6 15.0-13.6
Service Factor
1.60 1.60 1.50 1.50 1.40 1.40 1.30 1.30 1.20 1.20 1.15 1.15
Frame
56C 56J 56C 56J 56C 56J 56C 56J 56C 56J 56C 56J
Stock Number
B656 ★ B657 ★ B634 B638 B653 B654 B795 B796 B808 B809 B817 B818
▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Overload Protector
Shaft
"C" Dimension
Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto
Keyed Threaded Keyed Threaded Keyed Threaded Keyed Threaded Keyed Threaded Keyed Threaded
11.51 11.95 12.19 12.69 12.55 13.19 13.19 13.55 13.65 14.15 13.65 14.15
Notes
$ $ $ $ $ $ $ $ $ $ $ $
12 12 12 12 12 12
Two Speed “1081” • Full Rate • High Service Factor • 40°C Ambient HP
RPM
Service Factor Amps
Volts
Service Factor
Frame
Stock Number
Overload Protector
Shaft
"C" Dimension
Notes
High Speed Switchless, Low Speed Microswitch • Aluminum “C” Bracket • Hi-Lo Toggle Switch available (P/N 17590450) 3450/1725
1/2~.06 3/4 ~.10
3450/1725
1~.12
3450/1725
1-1/2~.20
3450/1725
2~.25
3450/1725
3~.38
3450/1725
115 115 115 115 230 230 230 230 115 230 230 230
8.8/3.55 8.8/3.55 11.2/5.0 11.2/5.0 6.3/2.3 6.3/2.3 8.9/3.1 8.9/3.1 14.6/4.4 10.6/3.2 10.6/3.2 13.8/4.0
1.60 1.60 1.50 1.50 1.40 1.40 1.30 1.30 1.10 1.20 1.20 1.15
56C 56J 56C 56J 56C 56J 56C 56J 56J 56C 56J 56J
B970 B971 B972 B973 B974 B975 B976 B977 B969 B978 B979 B966
★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★
Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto
Keyed Threaded Keyed Threaded Keyed Threaded Keyed Threaded Threaded Keyed Threaded Threaded
11.80 12.30 11.80 12.30 12.05 13.05 12.54 13.05 13.54 13.04 13.55 14.29
12 12 12 12 12,63,90 12 12
E-Plus® Energy Efficient “1081” • Centurion® • Full Rate • Cast Iron NEMA “C” Brackets • 50˚C Ambient HP
RPM
Volts
Service Factor Amps
Service Factor
Frame
3/4 1 1-1/2 2 3
3450 3450 3450 3450 3450
208-230/115 208-230/115 208-230/115 208-230 208-230
5.4-5.0/10.0 6.4-5.9/11.8 8.7-7.8/15.6 10.4-9.6 15.0-13.6
1.50 1.40 1.30 1.20 1.15
56C 56C 56C 56C 56C
Stock Number
B631 B723 B750 B772 B774
▲ ▲ ▲ ▲ ▲
Overload Protector
Shaft
"C" Dimension
Notes
Auto Auto Auto Auto Auto
Keyed Keyed Keyed Keyed Keyed
12.62 12.80 13.30 14.05 14.05
12 12 12 12 12
$ $ $ $ $
Notes: 12. 303 Stainless steel shaft 63. Speck Pump replacement motor 90. 50 degree C ambient ▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov
www.aosmithmotors.com
9
Two Compartment Square Flange Pool Filter Motors Single Speed & Energy Efficient Important: Features Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced Used on many Red Jacket, Pac Fab, American motor Products Important: Total Sta-Rite, output (HP x service factor) of replacement must equal or exceed motor being replaced and Sears Jet and Pool Pumps Used on many Sta-Rite, Red Jacket, Pac Fab, American Products and Sears Jet and Pool Pumps
Features: • Auto Protector • Capacitor Start •• High Service Factors • Open Drip ProofFactors All Copper Winding • High Service • Stainless Steel •- Rotation (CCW Pump End)50° • C303 Stainless Steel Threaded Shaft • Ambient •• Sealed Ball Bearings • 50° C Ambient • 60 HZ Auto Protector • Open Drip Proof 303 Threaded Shaft
SQ1032
SQ1152
• 60 HZ • Capacitor Start1
HIGH SERVICE FACTOR (FULL RATED) HP
RPM
Volts
Max. Amps
Service Factor
Frame
Stock Number
Approx. “AG”
1/3 1/2
3450 3450
3/4
3450
1
3450
1-1/2 2
3450 3450
115/230 115/230 115/230 115/230 115/230 115/230 115/208-230 230 230
9.9/5.0 13.4/6.7 9.6/4.8 15.3/7.6 12.6/6.3 19.2/9.6 16.0/8.0 10.4 11.2
1.95 1.9 1.9 1.65 1.65 1.65 1.65 1.47 1.3
48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y
SQ1032 SQ1052 QC1052 SQ1072 QC1072 SQ1102 QC1102 SQ1152 SQ1202
11-1/8 11-1/2 10-7/8 12-1/8 11-1/4 13-1/8 11-7/8 13-1/4 13-7/8
3
3450
230
15.4
1.15
56Y
SQ1302 ▲
Service Factor 1.3 1.27 1.27 1.27 1.25 1.25 1.25 1.1 1.1 1.1 1.1 1.0
Frame 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y
★ ▲ ▲ ▲ ▲
14
Notes
20
$
20
$
20 20 20 20
$ $ $ $
LOW SERVICE FACTOR (UP-RATED) HP 1/2 3/4
1
1-1/2
2 2-1/2
RPM 3450 3450
3450
3450
3450 3450
Volts 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 230 230
Max. Amps 9.9/5.0 13.4/6.7 11.8/5.9 9.6/4.8 15.3/7.6 12.6/6.3 14.8/7.4 19.2/9.6 19.2/9.6 16.0/8.0 10.4 11.2
Stock Number USQ1052 USQ1072 USQE1072 UQC1072 USQ1102 UQC1102 USQE1102 USQ1152 USQE1152 UQC1152 USQ1202 USQ1252
★ ▲
▲ ▲ ▲
Approx. “AG” 11-1/8 11-1/2 11-1/2 10-7/8 12-1/8 11-1/4 12-1/8 13-1/8 13-1/8 13-1/4 13-1/4 13-7/8
Notes
351 20 20 351 351 20 20 20
$ $
$ $ $
Notes: 20. $ Energy Efficient capacitor start, capacitor run “Conservationist” motor 351. eMod™ equipped motor See page 258 for mounting dimensions. eMod® motors on this page pass ASME A112.19.17 SVRS standard. eMod® will not prevent evisceration, hair, object or partial limb entrapment and is designed for suction lift applications. ▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov
10
www.aosmithmotors.com
Two Compartment Square Flange Pool Motors • Two Speed vFeatures Total output (HP x Service Factor) of replacement motor must Important: equal or exceed motor being replaced. Important: Total output (HP x Service Factor) of replacement motor must equal or exce Used on many Sta-Rite, Red Jacket, and Sears Jet and Pool Pumps.
Features: All Copper Windings • Auto Protector - Single Phase Used on many Sta-Rite, Red Jacket, and Sears Jet and Pool Pumps. • Open Drip Proof • Rotation (CCW Pump End) All Copper Windings • Shaft Open •Drip Proof • HZ Stinless Steel - (303) •• 303 Stainless Steel Threaded 50° C Ambient • 60 Auto Protector • Rotation (CCW PSC PumpHigh Speed Threaded Shaft •• Energy Efficient-1ø Capacitor Start Low Speed, • Capacitor Start1 End) • 50° C Ambient • 60 HZ Two-speed motors are shipped less hi/lo switch for remote operation. End cover and switch assembly kit number 615332-001 available and sold separately.
SQS1072R
SQS1152R
HIGH SERVICE FACTOR (FULL RATED) HP 3/4 ~1/8
RPM
Volts
Amps Hi - Lo
S.F.
Frame
Stock Number
3450/1725
115 230 230 230 230
13.0/4.2 6.1/2.1 9.5/2.5 10.0/3.0 11.3/3.3
1.65 1.60 1.65 1.47 1.3
48Y 48Y 48Y 48Y 48Y
SQL1072R SQS1072R SQS1102R SQS1152R SQS1202R
Stock Number
1~1/6 3450/1725 1-1/2~1/4 3450/1725 2~1/3 3450/1725
Approx. “AG” ★ ★ ★ ★ ★
Notes
$ $ $ $ $
12-5/8 12-5/8 13-13/16 13-9/16 13-13/16
LOW SERVICE FACTOR (UP-RATED) RPM
Volts
Amps Hi - Lo
S.F.
Frame
3450/1725
230
6.1/2.1
1.25
48Y
UQS1102R ★
12-5/8
$
1-1/2~1/4 3450/1725 2~1/3 3450/1725
230 230
9.5/2.5 10.0/3.0
1.1 1.1
48Y 48Y
UQS1152R ★ UQS1202R ★
13-13/16 13-9/16
$ $
HP 1~1/6
Approx. “AG”
Notes
Three Phase Square Flange Pump Motors Features • All Copper Windings • Stainless Steel • 50° C Ambient Features: All Copper Windings • Open Drip Proof • 303 Stainless Steel Threaded Shaft • Open Drip Proof (303) Threaded Shaft • 60 HZ • Sealed Ball Bearings • 50° C Ambient • 60 HZ • Sealed Ball Bearings HP
RPM
Volts
Max. Amps
1/2 3/4 1 1-1/2 2 3
3450 3450 3450 3450 3450 3450
208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 200-230/460
3.0/1.5 3.6/1.8 4.7/2.35 6.8/3.4 8.5/4.25 9.7/4.9
Service Factor
Frame
1.9 1.65 1.65 1.47 1.3 1.15
48Y 48Y 48Y 48Y 48Y 56Y
Stock Number Q3052 Q3072 Q3102 Q3152 Q3202 Q3302
Q3052
Overload Protector
Approx. “AG”
Notes
None None None None None None
9-7/8 10-3/8 10-7/8 11-7/8 12-5/8 12
31
Note: 31. 40 degree C ambient See page 258 for mounting dimensions. ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov
For fast, knowledgeable customer service and technical help for pool motors, call our toll free number: 1-866-887-5216.
www.aosmithmotors.com
11
Centurion® Pool and Spa Pump Motors Square Flange Permanent Split Capacitor • Switchless • Single Phase • Dripproof • No Base • 3600 and 3600/1800 RPM • 1/2 thru 3 HP Features: Ball bearing • 60 Hz • 50°C Ambient • Class B Insulated • Rotation (CCW Pump End) • Stainless Steel Shafts • $ Energy Efficient Applications: Replacement motor for Sta-Rite, HydroTech, Premier, AquaFlo, Red Jacket, Sears and Pac Fab/Pentair brand pumps. Can be used on Sta-Rite, Red Jacket and Sears home water systems. HP
RPM
Volts
Service Factor Amps
Service Factor
Centurion “1081” • Full Rate • High Service Factor 1⁄2 3450 230/115 5.4/10.8 1.95 3⁄4 3450 230/115 7.1/14.2 1.65 230/115 7.1/14.2 1.65 1 3450 230/115 8.0/16.0 1.65 230/115 8.0/16.0 1.65 1-1⁄2 3450 230/115 10.5/21.0 1.50 230 10.0 1.50 2 3450 230 11.5 1.30 Centurion® “1081” • Up-Rate • Low Service Factor 1⁄2 3450 230/115 4.0/8.0 1.30 3⁄4 3450 230/115 5.4/10.8 1.25 1 3450 230/115 7.1/14.2 1.25 230/115 7.1/14.2 1.25 1-1⁄2 3450 230/115 8.0/16.0 1.10 230/115 8.0/16.0 1.10 2 3450 230/115 11.2/22.4 1.10 230 10.0 1.10 230 10.0 1.10 2-1⁄2 3450 230 11.5 1.04 Centurion® II “1081” • Up-Rate • Low Service Factor 1⁄2 3450 230/115 3.6/7.2 1.30 E-Plus® Energy Efficient “1081” • Centurion • Full Rate 1⁄2 3450 208-230/115 4.5-4.4/8.8 1.90 3⁄4 3450 208-230/115 6.0-5.6/11.2 1.67 208-230/115 6.0-5.6/11.2 1.67 1 3450 208-230/115 7.8-7.4/14.8 1.65 7.8-7.4/14.8 208-230/115 1.65 1-1⁄2 3450 208-230 9.6-8.8 1.47 208-230 9.6-8.8 1.47 2 3450 208-230 11.0-10.0 1.30 208-230 11.0-10.0 1.30 3 3450 208-230 15.0-13.6 1.15 208-230 15.0-13.6 1.15
Frame
Stock Number
56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y
B846 B847 B847A B848 BE848 B858 B849 B748
★
56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y
B856 B852 B853 BE853 B854 BE854 B859 B855 BE855 B840
★
48Y
B856SM ★
56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y
B845 B661 B661A B841 B841A B842 B842A B843 B843A B844 B844A
B852
Shaft
Overload Protector
“C” Dim.
Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded
Auto Auto Auto Auto Auto Auto Auto Auto
12.44 12.44 12.44 12.81 12.87 14.44 13.44 13.44
Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded
Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto
12.44 12.44 12.44 12.44 12.82 12.77 14.44 13.44 13.39 13.44
Threaded
Auto
12.33
Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded
Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto
12.44 13.19 13.19 13.44 13.44 13.94 13.94 14.44 14.44 14.44 14.44
Notes
®
▲ ▲ ▲ ▲ ▲ ▲ ▲
★ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
★ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
352 351
351 351
351
1,158,235
$ $ 352 352 352 352 352
$ $ $ $ $ $ $ $ $
Notes: 1. Item to be discontinued when present stock is depleted 107. Uprated – Low Service Factor 158. Open motor construction, overload protector mounted at 12 o'clock 235. Centurion II motors are switchless. Designed in a 48-frame shell diameter that is .80 inches smaller in diameter than the 56-frame Centurion and Centurion SE designs. 351. eMod™ equipped motor 352. Pentair, almond paint, direct replacement motor eMod® motors on this page pass ASME A112.19.17 SVRS standard. eMod® will not prevent evisceration, hair, object or partial limb entrapment and is designed for suction lift applications. ▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov
For fast, knowledgeable customer service and technical help for pool motors, call our toll free number: 1-866-887-5216.
12
www.aosmithmotors.com
Centurion® Pool and Spa Pump Motors Square Flange Permanent Split Capacitor • Switchless • Single Phase • Dripproof • No Base • 3600 and 3600/1800 RPM • 1/2 thru 3 HP Features: Ball bearing • 60 Hz • 50°C Ambient • Class B Insulated • Rotation (CCW Pump End) • Stainless Steel Shafts • $ Energy Efficient Applications: Replacement motor for Sta-Rite, HydroTech, Premier, AquaFlo, Red Jacket, Sears and Pac Fab/Pentair brand pumps. Can be used on Sta-Rite, Red Jacket and Sears home water systems. HP
RPM
Volts
Service Factor Amps
Service Factor
Frame
Stock Number
Shaft
B852 Overload Protector
E-Plus® Energy Efficient “1081” • Centurion SE • Up-Rate 3⁄4 3450 208-230/115 4.5-4.4/8.8 1.25 56Y B862SE ★ Threaded Auto 1 3450 208-230/115 6.0-5.6/11.2 1.25 56Y B863SE ▲ Threaded Auto 1-1⁄2 3450 208-230/115 7.8-7.4/14.8 1.10 56Y B864SE ▲ Threaded Auto 2 3450 208-230 9.6-8.8 1.10 56Y B865SE ▲ Threaded Auto 2-1⁄2 3450 208-230 11 .0-10.0 1.04 56Y B866SE ▲ Threaded Auto Two Speed “1081” • Full Rate • High Service Factor • 40°C Ambient High Speed Switchless, Low Speed Microswitch • Square Flange • Hi-Lo Toggle Switch Assembly Available (Part # 17590450) .75~.12 3450/1725 230 6.0/2.3 1.67 56Y B980 ★ Threaded Auto . 75~.12 3450/1725 115 14.6/4.7 1.67 56Y B981 ★ Threaded Auto 1~.16 3450/1725 230 7.2/3.0 1.65 56Y B982 ★ Threaded Auto 1.5~.25 3450/1725 230 10.0/3.5 1.47 56Y B983 ★ Threaded Auto 2~.33 3450/1725 230 11.0/4.0 1.30 56Y B984 ★ Threaded Auto 230 10.0/3.5 1.10 56Y B985 ★ Threaded Auto
“C” Dim.
13.6 13.6 14.1 15.0 15.0
13.1 12.6 13.3 13.8 14.3 13.8
Notes
158 158 158
$
158
$
$ $ $
107
Notes: 107. Uprated – Low Service Factor 158. Open motor construction, overload protector mounted at 12 o'clock 351. eMod™ equipped motor eMod® motors on this page pass ASME A112.19.17 SVRS standard. eMod® will not prevent evisceration, hair, object or partial limb entrapment and is designed for suction lift applications. ▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov
www.aosmithmotors.com
13
Century® Above Ground Swimming Pool Pump Motors Jetted Tub/Spa/Above Ground Swimming Pool Pump Motors • Split Phase , Capacitor Start & PSC • Single-phase • Dripproof • Ball Bearing • Rigid Base & No Base • 3450 and 3450/1725 RPM • 1/2 thru 4 HP SPL Features: 12 & 3 O'clock Conduit Entries • 40°C Ambient • Class B Insulated • Rotation (CCW Pump End) • Through Bolt Mount • 48/56 Base Mounting • 3-1/2" Shaft Height • Four Thru Bolts on a 5.146 Bolt Circle Applications: Spa, above ground swimming pool and jetted tub pumps. Optional Flex-48 Accessories: Airswitch (#17800901), Single-speed Toggle Switch Assy. - On/Off (#18374501), Day/Night Controller (#18602401), Two-speed Toggle Switch Assy. - Lo/Off/Hi (#18313301)
BN24SS
Century Flex-48 W/Stainless Steel Shaft & Ball Bearings • "1081" • "1795" • "1563" • Rigid Base HP
RPM
1⁄2 3⁄4 1 1-1⁄2
3450 3450 3450 3450
2
3450
Volts
115 115 115 230/115 115 230/115
Hz
60 60 60 60 60 60
Full Load Amps
7.2 9.8 12.0 8.0/16.0 17.0 10.0/20.0
Service Factor
Frame
1.0 1.0 1.0 1.0 1.0 1.0
48Y 48Y 48Y 48Y 48Y 48Y
Stock Number
BN23SS BN24SS BN25SS BN35SS BV35SS BN40SS
Shaft
Threaded Threaded Threaded Threaded Threaded Threaded
Overload Protector
“C” Dim.
Notes
Auto Auto Auto Auto Auto Auto
11.08 11.08 11.58 12.08 12.08 13.33
Threaded Threaded Threaded Threaded Threaded
Auto Auto Auto Auto Auto
12.08 12.08 12.83 12.83 13.33
45 45 45 45
Threaded Threaded Threaded Threaded Threaded
Auto Auto Auto Auto Auto
12.83 12.83 13.33 14.33 14.33
45 68,145 68,145 68,90,145 68,90,145
“C” Dim.
Notes
45 45
Century Flex 48 LASAR Line (Low Amp Start and Run) • Two-speed • “1081” • “1563” • Rigid Base ®
3⁄4~.10 1~.12 1-1⁄2 ~.25 1-1⁄2 ~.18 2~.25
3450/1725 3450/1725 3450/1725 3450/1725 3450/1725
115 115 115 230 230
60 60 60 60 60
8.8/2.6 11.0/2.9 16.4/4.4 8.0/2.6 10.5/2.6
1.0 1.0 1.0 1.0 1.0
48Y 48Y 48Y 48Y 48Y
BN36 BN37 BN50 BN34 BN51
Century Flex 48 LASAR-XL • Extra Low Running Amps • Two-speed • Rigid Base 1~.12 1-1/2~.18 2~.25 3~.38 4.0~.42 SPL
3450/1725 3450/1725 3450/1725 3450/1725 3450/1725
115 115 230 230 208-230
60 60 60 60 60
10.3/3.1 13.8/3.8 8.5/2.8 12.0/3.5 12.0/3.5
1.0 1.0 1.0 1.0 1.0
48Y 48Y 48Y 48Y 48Y
BN38 BN60 ★ BN61 ★ BN62 ★ BN63 ★
ODB1102V1
Hoffinger Replacement (Doughboy/Lomart) • No Base HP
1
RPM
3450
Volts
Hz
Full Load Amps
Service Factor
Frame
Stock Number
Shaft
Overload Protector
115
60
10.0
1.0
48Y
BV90
Threaded
Auto
10.45
115
60
9.0
1.0
48Y
BV91
Threaded
Auto
10.22
285
Notes: 45. Capacitor start 68. PSC Motor 90 50˚C Ambient 145. Run capacitor mounted on motor shell 285. 3/8-16, Left hand threads, CWPE rotation
★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov
14
www.aosmithmotors.com
Two Compartment Pool Sweep Motors Smith-Seal Features: Auto Protector •Features Ball Bearings • Open Drip Proof • Single Speed • 40° C Ambient •• 60Auto HZ Protector • • • • •
Ball Bearings Open Drip Proof Single Speed 40° C Ambient 60 HZ
RPS1052
SPS1052
Special face mounted motors for use on Arneson “Pool Sweep”. HP
RPM
Volts
Max. Amps
Frame
Stock Number
Shaft
Notes
3/4
3450
115/230 115/230
12.4/6.2 12.4/6.2
48Y 48Y
SPS1052 RPS1052
Thrd Thrd
1,104 1,199
Notes: 1. Item to be discontinued when stock is depleted 104. Vertical Mount 199. Horizontal Rigid Base Pool Cleaner (Booster Pump) motors are not included in the California Energy Commission Appliance Regulations 2006 (Publication Number CEC 400-2006-002 REV1).
RPS/SPS
Sta-Rite Direct Replacement Spa Motors Features: • Open Construction • Rigid Base • Sealed Ball Bearing • Threaded Shaft • Thru-Bolt Mount • 50˚ C Ambient • 1.0 Service Factor • Energy Efficient • Auto Protector • 2-Speed (Capacitor Start Low Speed, PSC High Speed) • Rotation (CCW Pump End)
SDS1102
Replacement Motor for Dimension One, Hydroquip, GPM Industries, Hawkeye, Marquis and Master Spas
RPM
Volts
Amps
Frame
Stock Number
Insulation Class
Approx. “AG”
Dim. “BX”
1.0-.12
3450/1725
115
10.4/3.6
56Z
SDS1102 ★
B
10.30
8.85
1.5-.19
3450/1725
230
7.2/2.4
56Z
SDS1152 ★
F
10.79
9.34
2.0-.25
3450/1725
230
8.5/3.0
56Z
SDS1202 ★
F
11.42
9.98
2.5-.25
3450/1725
230
10.7/3.0
56Z
SDS1252 ★
F
10.67
9.23
3.0-.38
3450/1725
230
12.0/3.7
56Z
SDS1302 ★
F
10.92
9.48
HP
Notes
Note: When crossing to an original equipment A.O. Smith Motor, use the Quick Cross Reference table. Find the amps and model number of the OEM motor on the motor nameplate. Find the equivalent amps and model number on the Quick Cross Reference table below. The replacement is the stock number listed in the "Use" column. The horsepower and service factor may not be the same, but the motors are the same.
$ $ $ $ $
QUICK CROSS REFERENCE BY AMPS AND MOTOR MODEL NUMBER Name Plate Name Plate Use Amps Model No. Stock No. 10.4/3.6 K48L2A1 SDS1102 7.2/2.4 K48M2A4 SDS1152 8.5/3.0 K48N2A5 SDS1202 10.7/3.0 K48N2A4C2 SDS1252 12.0/3.7 K48P2A1 SDS1302 ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov
www.aosmithmotors.com
15
Century® Swimming Pool Pump Motors Squirrel Cage (Three Phase) • Dripproof • 3600/3000 RPM • 1/2 thru 3 HP Features: Ball bearings • 40°C Ambient • Class A or B Insulated • Cast Iron NEMA “C” Bracket • 303 Stainless Steel Shaft • Reversible (Three Phase) • 50/60 HZ
H281
60/50 Hz • Three Phase “1081” • Full Rate • High Service Factor Service Factor
Frame
Stock Number
Shaft
2.1-2.4/1.2 2.1-2.4/1.2 3.7-3.6/1.8 3.7-3.6/1.8 4.3-4.0/2.0 4.3-4.0/2.0
1.60 1.60 1.50 1.50 1.40 1.40
56C 56J 56C 56J 56C 56J
H281 H282 H450 H451 H513 H514
Keyed Threaded Keyed Threaded Keyed Threaded
208-230/460
5.9-5.6/2.8
1.30
56C
H616
208-230/460
5.9-5.6/2.8
1.30
56J
208-230/460
7.0-6.6/3.3
1.20
56C
HP
RPM
Volts
1⁄2
3450
3⁄4
3450
1
3450
208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460
1-1⁄2
3450
2
3450
Service Factor Amps@ 60 Hz
Overload Protector
Insul. Class
“C” Dim.
Notes
None None None None None None
A A A A A A
11.87 12.05 12.80 12.12 12.62 12.12
282 282 282 282 282 282
Keyed
None
A
13.24
282
H617
Threaded
None
A
12.62
282
H704
Keyed
None
A
13.62
282
Notes: 257. 60 Hz, only 282. 3450 RPM for 60 Hz and 2875 RPM for 50 Hz
Century® Pool Cleaner Replacement Pump Motors Permanent Split Capacitor • Switchless • Single Phase • Dripproof • No Base & Rigid Base • 3600 RPM Features: Ball bearings • 60 Hz • 40°C Ambient • Class B Insulated • CW Non-Reversible • 303 Stainless Steel Shaft • “1081” Features • Aluminum Adapter Bracket
B662 & B663
Applications: Replacement motor for Arneson “Pool Sweep,” Polaris “Vac-Sweep” and Letro "Jet Vac" brand pool cleaners. HP
RPM
Volts
3⁄4
3450
230/115 230/115 230/115 230/115 230/115 230/115
Service Factor Amps
6.4/12.8 6.4/12.8 6.0/12.0 6.0/12.0 6.0/12.0 6.5/13.0
Service Factor
Frame
Stock Number
1.50 1.50 1.50 1.50 1.50 1.50
56CZ 56CZ 56Y 56Y 56Y 56CZ
B625 BE625 B662 B663 B667 B668
Shaft
Threaded Threaded Threaded Threaded Threaded Threaded
Base
Mount
Overload Protector
“C” Dim.
Brand
Notes
None None Rigid None Rigid None
Horizontal Horizontal Horizontal Vertical Horizontal Horizontal
Auto Auto Auto Auto Auto Auto
14.03 14.03 11.74 10.89 12.97 13.87
Polaris Polaris Arneson Arneson Letro Letro
222 222,351 12 12 12,247 246
Notes: 12. 303 Stainless steel shaft 222. Does not have Aluminum Adapter Bracket 246. B668 fits pump #LA01N manufactured March 1997 to present 247. B667 fits pump #LA01 manufactured March 1997 and prior 351. eMod® equipped motor eMod® motors on this page pass ASME A112.19.17 SVRS standard. eMod® will not prevent evisceration, hair, object or partial limb entrapment and is designed for suction lift applications.
Pool Cleaner (Booster Pump) motors are not included in the California Energy Commission Appliance Regulations 2006 (Publication Number CEC 400-2006-002 REV1).
Pool cleaner (booster pump motors) are not included in the California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1).
16
www.aosmithmotors.com
Century® Purex Replacement Pump Motors Horizontal • Dripproof • No Base • 60 and 50 Hz • 3450 and 3450/2850 RPM • 5 thru 20 HP Features: Ball Bearings • 40°C Ambient • Service Factor 1.15 • Reversible • External Slinger Applications: Hydrotech (Purex) East Side “L” Series and “C” Series commercial pump. R236 HP
RPM
Volts
Full Load Amps
Hertz
Frame
Insul Class
Stock Number
Overload
“C” Dim.
Efficiency
Notes
Single Phase • Capacitor Start 5
3450
Three Phase 15.75 5 3450
230 230
60 60
25.6 25.6
184TY 184TY
B B
V214 V220
None None
15.7 15.8
77.0 77.0
153 152
60 60 60
14.0-13.5/6.75 14.0-13.5/6.75 21.6-19.4/9.7
182TY 182TY 184TY
F F F
R237 R236 R232
16.2 15.0 14.7
81.0 81.0 82.0
153 152 153
60 60
28.0-26.0/13.0 40.0-38.0/19.0
213TY 215TY
B F
R338 R339
None None None None None
19.4 21.4
87.5 88.6
153 153
7-1⁄2
3450
208-220/440 208-220/440 208-220/440
10 15
3450 3450
208-220/440 208-220/440
Notes: 1. Item to be discontinued when stock is depleted 152. Pump Series: L (threaded) 153. Pump Series: C (keyed)
Century® Square Flange Pool and Spa Pump Motors Squirrel Cage • Three Phase • Dripproof • No Base • 3600 RPM • 1/2 thru 3 HP Features: Ball bearings • 60 Hz • 50°C Ambient • Class B Insulated • 303 Stainless Steel Threaded Shafts
Service Factor Amps@ 60 Hz
HP
RPM
Volts
1⁄2 3⁄4 1 1-1⁄2 2 3
3450 3450 3450 3450 3450 3450
208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460
3.2-3.0/1.5 3.8-3.6/1.8 5.0-4.6/2.3 6.4-5.8/2.9 7.1-6.8/3.4 9.0-8.6/4.3
Service Factor
Frame
Stock Number
Shaft
1.90 1.65 1.65 1.47 1.30 1.15
56Y 56Y 56Y 56Y 56Y 56Y
H491 H492 H635 H636 H637 H755
Threaded Threaded Threaded Threaded Threaded Threaded
H491
Overload Protector
None None None None None None
“C” Dim.
Notes
12.2 12.8 13.2 13.4 13.9 13.9
Century® Pentair/Pac Fab Replacement Pump Motors Square Flange • Horizontal • Dripproof • No Base • 60 Hz B1000
Features: Ball Bearings • 40°C Ambient • Class B Insulation HP
Volts
Hertz
Full Load Amps
Service Factor
Frame
208-230 208-220/440
60 182TY
21.0-19.4 14.0-13.5/6.75
1.0 60/50
56Y C
208-230/460 208-230/460
60 60
11.0-10.4/5.2 13.4-13.4/6.7
1.15 1.0
56Y 56Y
RPM
Stock Number
Pac Fab Number
“C” Dim.
B1000 ▲ 81.
35-5705
14.9
H994 H995
35-5398 35-5704
13.9 14.9
Notes
Single Phase PSC "1081" 5
3450
5 3600/2900 Three Phase "1081" 3 5
3450 3450
▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov
www.aosmithmotors.com
17
Century® Waterway Replacement Pump Motors Dripproof • 60 HZ • Single Phase • Rigid Base • 6-1/2” Diameter • 3-1/2” Shaft Height Features: Ball Bearings • 50°C Ambient • 3/8-16 UNC-2A threads includes Slinger • Four thru bolts on a 5.812 Bolt Circle • Auto Protector • Permanent Split Capacitor
B232
HP-SPL
RPM
Volts
Full Load Amps
Frame
Stock Number
Insul. Class
“C” Dim.
Waterway Number
1.0 ~.18 2.0 ~.25 3.0 ~.30 4.0 ~.50 5.0 ~.63 4.0 5.0
3450/1725 3450/1725 3450/1725 3450/1725 3450/1725 3450 3450
230 230 230 230 230 230 230
6.4/2.6 8.0/3.0 10.0/3.5 12.0/4.4 16.4/4.8 12.0 16.4
56Y 56Y 56Y 56Y 56Y 56Y 56Y
B232 ★ B233 ★ B234 ★ B235 ★ B236 ★ B237 ▲ B238 ▲
F F F F F B B
10.87 11.87 12.12 13.37 13.37 12.62 13.37
3720621 3721021 3721421 3721621 3722021 3711821 3712021
Notes 108 108 108 108 108
Note: 108. Two speed motor
Century® Hayward North s tar Replacement Pump Motors NEMA C-Face • Dripproof • No Base • 60 Hz • Energy Efficient Features: Ball Bearing • Insulation Class B • Switchless • 50˚C Ambient • 60 Hz • E-Coated Main Frame for Superior Corrosion Resistance • 303 Stainless Steel Shaft • Low Noise • Cool Running for Longer Winding Life
SN1072
Volts
Full Load Amps
Service Factor
Frame
3450 3450 3450 3450 3450
208-230/115 208-230/115 208-230/115 208-230 208-230
6.0-5.5/11.0 8.5-7.8/15.6 11.0-10.2/20.4 13.0-11.8 20.6-19.0
1.85 1.85 1.60 1.35 1.60
56J 56J 56J 56J 56J
SN1072 SN1102 SN1152 SN1202 SN1302
▲
3450 3450 3450 3450 3450
208-230/115 208-230/115 208-230/115 208-230 208-230
6.0-5.5/11.0 8.5-7.8/15.6 11.0-10.2/20.4 13.0-11.8 16.0-14.8
1.40 1.25 1.20 1.10 1.20
56J 56J 56J 56J 56J
USN1102 USN1152 USN1202 USN1252 USN1302
▲
HP
RPM
Stock Number
Industry Number
“C” Dim.
SP1607Z1BNSC SP1610Z1BNSC SP1615Z1BNSC SP1620Z1BNSC SP1630Z1BNSC
13.10 13.35 13.85 14.60 16.10
$
Sp1607Z1MNSC SP1610Z1MNSC SP1615Z1MNSC SP1620Z1MNSC SP1625Z1MNSC
13.10 13.35 13.85 14.60 14.85
$
Notes
Full Rated 3/4 1 1-1/2 2 3
▲ ▲ ▲ ▲
$ $ $ $
Uprated 1 1-1/2 2 2-1/2 3
▲ ▲ ▲ ▲
$ $ $ $
▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov
18
www.aosmithmotors.com
Century® Close-Coupled Pump Motors Types JM, JP and TCZ • Three-Phase • Horizontal • Dripproof • Rigid Base • 3600 and 1800 RPM • 60 Hz • 1 thru 40 HP Features: Ball Bearings • 60 Hz • 40°C Ambient • Class B or F Insulated • External Slinger • Oversized, Locked Shaft End Bearing • Frame Suffix Letters TCZ Designate Century West Coast Pump Standard Motors Applications: Commercial/industrial pump duty. Designed to meet a wide variety of applications for fluid transfer E117
HP
RPM
Volts
Full Load Amps
Service Factor
Frame
1
1800
200-230/460 230/460 200-230/460 230/460 230/460 200-230/460 230/460 230/460 200-230/460 230/460 200-230/460 230/460 230/460 200-230/460 230/460 230/460 200-230/460 230/460 200-230/460 208-230/460 230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460
3.5-3.8/1.9 3.8/1.9 4.5-4.2/2.1 4.2/2.1 4.2/2.1 5.0-5.6/2.8 5.6/2.8 5.6/2.8 6.2-5.6/2.8 5.3/2.65 6.2-6.4/3.2 6.4/3.2 6.4/3.2 9.0-8.6/4.3 8.6/4.3 8.6/4.3 9.1-8.8/4.4 8.8/4.4 9.2-8.6/4.3 13.4-13.2/6.6 13.4/6.7 14.2-13.0/6.5 15.5-15.0/7.5 15.5-15.0/7.5 15.5-15.0/7.5 21.8-20.0/10.0 22.0-19.0/9.5 20.5-17.2/8.6 22.0-21.0/10.5 22.0-21.0/10.5 22.0-21.0/10.5 28.2- 27.0/13.5 28.2- 27.0/13.5 29.0-27.0/13.5 30.0-26.0/13.0 26.0/13.0 34.0-26.0/13.0 42.0-38.0/19.0 42.0-38.0/19.0 42.0-38.0/19.0 46.0-39.6/19.8 46.0-39.6/19.8 55.0-51.0/25.5 55.0-51.0/25.5 55.0-51.0/25.5 58.0-53.6/26.8 58.0-53.6/26.8 67.0-61.0/30.5 67.0-61.0/30.5 67.0-61.0/30.5 67.0-60.0/30.0 67.0-60.0/30.0
1.15 1.25 1.15 1.25 1.25 1.15 1.25 1.25 1.15 1.25 1.15 1.25 1.25 1.15 1.25 1.25 1.15 1.25 1.15 1.15 1.25 1.15 1.15 1.15 1.15 1.15 1.25 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.25 1.25 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15
143JM 143JP 143JM 143JP 143TCZ 145JM 145JP 145TCZ 145JM 145JP 145JM 145JP 145TCZ 145JM 145JP 145TCZ 182JM 182JP 182TCZ 182JM 182JP 182TCZ 184JM 184JP 184TCZ 184JM 184JP 184TCZ 213JM 213JP 213TCZ 213JM 213JP 213TCZ 15JM 215JP 215TCZ 215JM 215JP 215TCZ 254JM 254JP 254JM 254JP 254TCZ 256JM 256JP 256JM 256JP 256TCZ 284JM 284JP
1-1⁄2
3600
1800
2
3600 1800
3
3600
1800
5
3600
1800
7-1⁄2
3600
1800
10
3600
1800
15
3600
1800 20
3600
1800 25
3600
1800
Note: 1. Item to be discontinued when stock is depleted 6. 60/50 HZ 21. Terminal in bracket construction For mounting dimensions, see page 261
www.aosmithmotors.com
Stock Number
E117 E118 E119 E148 E149 E156 E157 E158 E159 E172 E174 E175 E176 E177 E178 E179 E294 E295 E276 E296 E297 E279 E282M E283M E284M E285M E286M E287M E368 E369 E370 E371M E372M E373M E374 E375 E376M E377 E378 E379 E482 E483 E485 E486 E487 E488 E489 E491 E492 E493 E566 E567
Insulation Class
B B B B B B B B B B B B B B B B B F B B F B F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F
"C" Dim.
14.40 17.85 14.87 17.85 17.85 14.87 17.85 17.85 15.40 17.85 15.40 17.85 17.85 15.40 17.85 17.85 16.88 19.94 18.02 17.12 20.18 19.52 14.97 19.11 18.02 16.97 20.78 20.78 17.43 21.31 20.49 18.43 22.31 21.49 17.43 21.31 20.47 19.93 23.81 22.59 20.88 20.88 23.60 26.48 26.48 23.60 26.48 23.60 26.48 26.48 24.86 27.74
Efficiency
Notes
84.0 81.5 86.5 86.5 86.5 84.0 81.5 81.5 82.5 82.5 81.5 81.5 81.5 84.0 84.0 84.0 85.5 85.5 84.0 86.5 86.5 80.0 82.5 85.5 85.5 82.0 85.5 87.5 87.5 87.5 87.5 86.5 86.5 88.5 88.5 88.5 88.5 88.5 88.5 88.5 88.5 88.5 90.2 90.2 90.2 87.5 87.5 90.2 90.2 90.2 91.0 91.0
6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21
1 1
Continued on next page
19
Century® Close-Coupled Pump Motors
Continued from previous page
Types JM, JP and TCZ • Three-Phase • Horizontal • Dripproof • Rigid Base • 3600 and 1800 RPM • 60 Hz • 1 thru 40 HP Features: Ball bearings • 60 Hz • 40°C Ambient • Class B or F Insulated • External Slinger • Oversized, Locked Shaft End Bearing • Frame Suffix Letters TCZ Designate Century West Coast Pump Standard Motors • 1.15 Service Factor Applications: Commercial/industrial pump duty. Designed to meet a wider variety of applications for fluid transfer.
HP
RPM
30
3450 1725
40
3450
Volts
200-230/460 200-230/460 200-230/460 200-230/460
E569
Full Load Amps
Frame
Stock Number
Insulation Class
"C" Dim.
Efficiency
Notes
81.0-70.0/35.0 81.0-72.0/36.0 81.0-72.0/36.0 104.0-90.0/45.0
284JM 286JM 286JP 286JP
E569 E572 E573 E576
F F F F
24.86 26.36 29.24 29.24
89.5 91.7 91.7 91.0
1 1 1 1
Century® Close-Coupled Pump Motors Three Phase • Type JM • Dripproof • NEMA “C” Face • No Base • 50/60 Hz Features: Double Sealed Ball Bearings, 60/50 Hz Markings on Nameplate, 40°C Ambient, Class B Insulated, External Shaft Slinger, Oversized, Locked Shaft End Bearing, Terminal In Bracket Construction.
E159RF
Applications: Commercial pump duty. Designed to meet a wide variety of applications for fluid transfer. HP
RPM
1 1.5 2
1800 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800
3 5 7.5 10
Volts
200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 208-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460
Full Load Amps
Service Factor
3.5-3/8/1.9 5.0-5.6/2.8 6.2-5.6/2.8 6.2-6.4/3.2 9.0-8.6/4.3 9.1-8.8/4.4 13.4-13.2/6.6 15.5-15.0/7.5 21.8-20.0/10.0 22.0-21.0/10.5 29.0-27.0/13.5 34.0-26.0/13.0
1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.25 1.25 1.15 1.15 1.25
Frame
Stock Number
"C" Dim.
143JM 145JM 145JM 145JM 145JM 182JM 182JM 184JM 184JM 213JM 213JM 215JM
E117RF E156RF E159RF E174RF E177RF E294RF E296RF E282RF E285RF E368RF E371RF E374RF
14.4 14.9 15.4 15.4 15.4 16.9 17.1 15.0 17.0 17.5 18.4 17.5
Efficiency
Notes
84.0 84.0 84.0 81.5 84.0 85.5 86.5 85.5 82.0 87.5 88.5 88.5
220 220
Notes: 1. Item to be discontinued when stock is depleted 220. Dripcover kit available (Part # 103017-02). For mounting dimensions, see page 261
20
www.aosmithmotors.com
Century® Industrial Close-Coupled Pump Motors Types JM, JP and TCZ • Three-Phase • Horizontal • TEFC • Rigid Base • 3600 and 1800 RPM • 1 thru 25 HP Features: Ball Bearings • 60 Hz • 40°C Ambient • Class B or F Insulated • Service Factor 1.15 • External Slinger • Oversized, Locked Shaft End Bearing • Frame Suffix Letters JM and JP Designate NEMA Standard Motors. Frame Suffix TCZ Designates Century West Coast Pump Standard Motors. N346
Applications: Designed for the specific requirements of centrifugal pumps.
HP
RPM
Volts
Full Load Amps
Frame
1
1800 3600 1800 3600 1800 3600
200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 230/460 208-230/460 200-230/460 230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 230/460 200-230/460 200-230/460
3.3-3.4/1.7 4.5-4.2/2.1 4.5-4.4/2.2 6.0-5.3/2.65 5.9-5.6/2.8 7.8/3.9 8.5-8.2/4.1 8.2-7.2/3.6 10.4/5.2 10.4/5.2 8.4/4.2 9.0-8.0/4.0 9.0-8.0/4.0 13.0/6.5 13.0/6.5 12.0/6.0 13.9-11.8/5.9 13.9-11.8/5.9 13.6/6.8 13.6/6.8 13.0/6.5 15.0-12.8/6.4 15.0-12.8/6.4 19.0/9.5 19.0/9.5 21.2-18.8/9.4 21.2-18.8/9.4 20.0/10.0 20.0/10.0 19.6/9.8 21.0-18.9/9.45 21.0-18.9/9.45
143JM 143JM 145JM 145JM 145JM 182JM 145JM 182JM 182JM 182JP 182TCZ 182JP 182JM 184JM 184JP 184TCZ 184JM 184JP 184JM 184JP 184TCZ 184JP 184JM 213JM 213JP 213JM 213JP 213JP 213JM 213TCZ 213JP 213JM
1-1⁄2 2 3
1800
5
3600
1800
7-1⁄2
3600
1800
Stock Number
N149 N148 N161 N153 N163 N223 N157 TCP71004 N232 N252 N251 TCP72029 TCP71029 N245 N240 N209 TCP71005 TCP72005 N246 N219 N211 TCP72030 TCP71030 N342 N335 TCP71006 TCP72006 N329 N344 N311 TCP72031 TCP71031
Insulation Class
B B B B B F B F F F F F F F F F F F F F F F F F F F F F F F F F
Cast Iron
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
"C" Dim.
16.0 16.0 16.0 16.0 16.0 18.2 17.5 17.2 18.2 21.3 21.1 20.9 17.2 18.2 21.3 21.1 17.2 20.9 18.2 21.3 21.1 20.9 17.2 21.4 25.3 21.1 24.9 25.5 21.4 22.6 24.9 21.1
Efficiency
Notes
82.5
1,291 291
85.5 82.5 82.5 85.5 87.5 87.5 83.5 83.5 85.5 87.5 87.5 86.5 86.5 86.5 87.5 87.5 85.5 85.5 88.5 88.5 86.5 86.5 86.5 89.5 89.5
1,291 1 291
1,291 1 291
1,291 1 291
1,291 1
1 1,291 333
Notes: 1. Item to be discontinued when stock is depleted 291. 208 Volt @ 1.0 Service Factor 333. Aluminum shell For mounting dimensions, see page 261
www.aosmithmotors.com
21
Continued from previous page
Century® Industrial Close-Coupled Pump Motors Types JM, JP and TCZ • Three-Phase • Horizontal • TEFC • Rigid Base • 3600 and 1800 RPM • 1 thru 25 HP Features: Ball Bearings • 60 Hz • 40°C Ambient • Class B or F Insulated • Service Factor 1.15 • External Slinger • Oversized, Locked Shaft End Bearing • Frame Suffix Letters JM and JP Designate NEMA Standard Motors. Frame Suffix TCZ Designates Century West Coast Pump Standard Motors.
N346
Applications: Designed for the specific requirements of centrifugal pumps.
HP
RPM
Volts
Full Load Amps
Frame
10
3600
230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460
26.0/13.0 26.0/13.0 25.0/12.5 29.4-24.0/12.0 29.4-24.0/12.0 26.0/13.0 26.0/13.0 28.3-25.2/12.6 28.3-25.2/12.6 36.0/18.0 36.0/18.0 40.0-35.0/17.6 40.0-35.0/17.6 36.0/18.0 36.0/18.0 40.9-36.6/18.3 40.9-36.6/18.3 46.0/23.0 46.0/23.0 53.2-47.0/23.5 53.2-47.0/23.5 48.0/24.0 48.0/24.0 56.7-49.2/24.6 56.7-49.2/24.6 60.0/30.0 60.0/30.0 66.1-59.0/29.5 66.1-59.0/29.5 62.0/30.0 63.0/31.5 67.9-62.0/31.0 67.9-62.0/31.0
215JM 215JP 215TCZ 215JM 215JP 215JM 215JP 215JP 215JM 254JM 254JP 254JM 254JP 254JM 254JP 254JM 254JP 256JM 256JP 256JM 256JP 256JM 256JP 256JP 256JM 284JM 284JP 284JM 284JP 284JM 284JP 284JM 284JP
1800
15
3600
1800
20
3600
1800
25
3600
1800
Stock Number
N343 N346 N313 TCP71007 TCP72007 N345 N347 TCP72032 TCP71032 N417 N432 TCP71008 TCP72008 N424 N419 TCP71033 TCP72033 N425 N433 TCP71009 TCP72009 N426 N435 TCP72034 TCP71034 N516 N523 TCP71010 TCP72010 N535 N525 TCP71035 TCP72035
Insulation Class
Cast Iron
"C" Dim.
Efficiency
Notes
F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F
√ √
21.0 24.8 24.1 21.1 24.9 21.6 25.5 24.9 21.1 26.8 29.6 26.9 29.8 26.8 29.6 26.9 29.8 26.8 29.6 26.9 29.8 26.1 29.6 29.8 26.9 28.4 28.0 27.8 30.7 25.9 28.0 27.8 30.7
84.0 84.0 85.5 89.5 89.5 88.5 88.5 89.5 89.5 86.5 86.5 90.2 90.2 89.5 89.5 91.0 91.0 87.5 87.5 90.2 90.2 91.7 91.0 91.0 91.0 87.5 87.5 91.0 91.0 91.7 91.7 92.4 92.4
1,291 1 333
√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
1,291 1
1 1
1 1
1 1
1 1
1 1
1 1
Notes: 1. Item to be discontinued when stock is depleted 291. 208 Volt @ 1.0 Service Factor 333. Aluminum shell For mounting dimensions, see page 261
22
www.aosmithmotors.com
Century® Close-Coupled Pump Motors Types JM, JP and WCP • Single-Phase • Horizontal • Dripproof • Rigid Base • 3600 and 1800 RPM • 1 thru 10 HP Features: Double Sealed Ball Bearings • 60 Hz • 40°C Ambient • Class B Insulated • Service Factor 1.15 • Reversible • External Slinger • Oversized, Locked Shaft End Bearing. • Frame suffix letters JM and JP Designate NEMA Standard Motors. Frame suffix TCZ Designates Century West Coast Pump Standard Motors.
P137
Applications: Designed for the specific requirements of centrifugal pumps.
HP
RPM
Volts
Full Load Amps
Frame
1
1800
1-1⁄2
3600
115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 230 230 200 115/230 115/230 230 230 200 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230
15.0/7.5 15.0/7.5 16.0/8.0 16.0/8.0 15.0/7.5 18.0/9.0 19.2/9.6 19.2/9.6 20.4/10.2 25.0/12.5 25.0/12.5 13.4 13.4 15.6 32.0/16.0 34.0/17.0 20.0 22.0 24.0 26.0 26.0 26.0 25.0 25.0 25.0 39.0 39.0 39.0 32.0 32.0 32.0 42.5 42.5 42.5
143JM 143JP 143JM 143JP 145JM 145JP 145JM 145JP 182JM 182JM 182JP 182JM 182JP 182JM 182JM 184JM 184JM 184JP 184JM 184JM 184JP 184TCZ 213JM 213JP 213TCZ 213JM 213JP 213TCZ 215JM 215JP 215TCZ 215JM 215JP 215TCZ
1800 2
3600 1800
3
3600
5
1800 3600
1800
7-1⁄2
3600
1800
10
3600
Stock Number
P121 P126 P122 P127 P123 P128 P124 P129 P137 P228 P232 P130 P131 P132 P229 P230 P140 P135 P133 P231 P235 P212 P317 P324 P312 P318 P325 P311 P319 P326 P313 P320 P327 P321
"C" Dim.
15.54 18.60 15.54 18.60 16.29 18.60 15.54 18.60 16.29 16.04 18.93 16.29 19.35 16.29 16.04 17.04 17.12 20.10 17.04 17.04 19.93 20.11 17.63 20.69 20.69 17.63 20.69 20.69 19.13 22.19 22.19 19.13 22.19 22.19
Efficiency
Notes
21 21 21 21 21 21 21 21 21 72.5 72.5 21 21 21 72.2 77.0 83.9 21 21 78.5 78.5 77.0 81.0 81.0 81.0 77.0 77.0 86.0 86.0 86.0 86.0 83.8 83.8 83.8
Notes: 21. Terminal in bracket construction For mounting dimensions, see page 261
www.aosmithmotors.com
23
Commercial Pump Motor Cross Reference SINGLE-PHASE HP 3 3 3 5 5 5 5 7.5 7.5 10
RPM 3600 3600 1800 3600 3600 3600 1800 3600 1800 3600
230 (115) VOLT ODP
FRAME 182JM 182JM 184JM 184JM 184TY 184TY 184JM 213JM 215JM 215JM
AOS P229 P130 P230 P231 V214 V220 P317 P318 P319 P320
MARATHON Z406
BALDOR JML1406T
Z407 Z408
JML1408T JML1409T
EMERSON
GE
STA-RITE BERKLEY
ITT-MARLOW
AURORA
PENTAIR/PUREX
DMH/DDH DMJ/DHJ
3B28EC-C2-1 CH50/CM50 LH50
Z409 Z410 Z411 Z412
JML1508T JML1509T JML1510T JML1511T
CSPHK
3B32EC-C2-1 341A-3X4X9B-7.5-1
CSPHL
THREE-PHASE 230/460 VOLT ODP HP 3 3 5 5 5 5 7.5 7.5 7.5 10 10 10 15 15 15 20 20 20 25 25
RPM 3600 1800 3600 3600 3600 1800 3600 3600 1800 3600 3600 1800 3600 3600 1800 3600 3600 1800 3600 1800
FRAME 145JM 182JM 182JM 182TY 182TY 184JM 184JM 184TY 213JM 213JM 213TY 215JM 215JM 215TY 254JM 254JM 254TY 256JM 256JM 284JM
AOS E177 E294 E296 R237 R236 E282 E285 R232 E368 E371 R338 E374 E377 R339 E482 E485 R346 E488 E491 E566
MARATHON M311 M313 M315
BALDOR JMM3158T JMM3211T JMM3212T
EMERSON DJ3S1AM DJ3S2AM DJ5S1AM
GE N846 N704 N705
STA-RITE BERKLEY DMH3/DHH3
ITT-MARLOW
DMJ3/DHJ3
3B28EC-C2-3
AURORA
PENTAIR/PUREX
CHK50/CMK50 LHK50 M317 M319
JMM3218T JMM3219T
DJ5S2AM DJ7S1AM
N706 N707
M321 M323
JMM3311T JMM3312T
DJ7S2AM DJ10S1AM
N708 N709
M325 M327
JMM3313T JMM3314T
DJ10S2AM DJ15S1AM
N710 N711
CSPHM3
M329 M330
JMM2514T
DJ15S2AM DJ20S1AM
N712 N713
CSPHN3
DJ20S2AM DJ25S1AM DJ25S2AM
N714 N715 N716
EMERSON UJ3S1AM UJ3S2AM UJ5S1AM UJ5S2AM UJ7S1AM UJ7S2AM UJ10S1AM UJ10S2AM UJ15S1AM UJ15S2AM UJ20S1AM UJ20S2AM UJ25S1AM UJ25S2AM
GE N735 N737 N738 N739 N740 N741 N742 N743 N744 N745 N746 N747 N748 N749
CSPHK3
3B32EC-C2-3 CMK75/CHK75
M331 M332 M333
JMM2515T JMM2516T
341A-3X4X9B-7.5-3 CSPHL3
L SERIES L SERIES L SERIES L SERIES L SERIES L SERIES L SERIES L SERIES L SERIES
CMK100/CHK100 341A-3X4X9B-10-3 CMK150/CHK150 341A-3X4X9B-15-3 CHK200 341A-4X5X11-20-3 341A-4X5X11-25-3
THREE-PHASE 208-230/460 VOLT TEFC HP 3 3 5 5 7.5 7.5 10 10 15 15 20 20 25 25
24
RPM 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800
FRAME 182JM 182JM 184JM 184JM 213JM 213JM 215JM 215JM 254JM 254JM 256JM 256JM 284JM 284JM
AOS N223 N232 N245 N246 N342 N344 N343 N345 N417 N424 N425 N426 N516 N535
MARATHON M405 M406 M407 M408 M409 M410 M411 M412 M413 M420 M414 M421
BALDOR JMM3610T JMM3611T JMM3613T JMM3615T JMM3709T JMM3710T JMM3711T JMM3714T JMM2394T JMM2333T JMM4106T JMM2334T JMM4107T JMM4103T
STA-RITE BERKLEY
ITT-MARLOW
AURORA
PENTAIR/PUREX
M08311 M10490 S34562
www.aosmithmotors.com
ENERGY SAVINGS ESTIMATOR Your pool professional can tell you which High Efficiency Motor on the chart below replaces your current swim pool pump motor. The High Efficiency Motor will save you money every month on your electric bill. Use the chart below to find your yearly savings. Divide the cost of a new High Efficiency Motor by yearly savings and the result is how long it will take to get your money back. At the end of the payback period, you will have saved the cost of the motor in energy bills and the ongoing savings will go directly into your pocket.
Approximate yearly energy savings based on using an Energy Efficient motor in place of a standard pool and spa motor with industry-average efficiency: “C” Flange: Hayward – Jacuzzi and Others Hours Per Day Operation
E n e rgy Efficient Models HP
Square Flange: Sta-Rite – Pentair and Others Hours Per Day Operation
Century®
8
10
12
$27.95
$34.94
$41.93
1/2
1.60
$27.95
$34.94
$41.93
3/4
1.00
$34.08
$42.72
$51.24
3/4
1.50
$34.08
$42.72
$51.24
1
1.00
$32.04
$40.08
$48.00
1
1.40
$32.04
$40.08
$48.00
1-1/2
1.00
$49.20
$61.44
$73.80
1-1/2
1.30
Energy Efficient Models HP
SF B656, B657
B631, B634, B638
AOSmith
8
10
12
AOSmith
CT1052
$57.24
$71.64
$85.92
1/2
1.90
B845
QC1052
$57.24
$71.64
$85.92
3/4
1.25
B862SE
UQC1072
CT1072
$36.00
$45.12
$54.12
3/4
1.67
B661
QC1072
$36.00
$45.12
$54.12
1
1.25
B863SE
UQC1102
$55.20
$69.00
$82.80
1
1.65
B841
QC1102
$55.20
$69.00
$82.80
1-1/2
1.10
B864SE
UQC1152
$65.76
$82.32
$98.76
1-1/2
1.47
B842
SQ1152
$65.76
$82.32
$98.76
2
1.10
B865SE
USQ1202
$71.16
$89.04
$106.80
2
1.30
B843
SQ1202
$71.16
$89.04
$106.80
2-1/2
1.04
B866SE
USQ1252
$16.08
$20.02
$24.12
3
1.15
B844
SQ1302
CT1102 UCT1152
B750, B795, B796
Century®
UCT1072
UCT1102 B653, B654, B723
SF
ST1152
$61.44
$76.92
$92.28
2
1.20
B772, B808, B809
ST1202
$16.08
$20.04
$25.20
3
1.15
B774, B817, B818
ST1302
Bulletin #1081/1082 04-07