A.O. Smith - Magnetek Catalog - Pool Supply Unlimited

33 downloads 3281 Views 2MB Size Report
observation and no later than one year of the date A. O. Smith manu- factured the ..... Find your pump brand, listed in alphabetical order at the right. .... Pump rated for 115/230 Volt, check voltage supply to ensure replacement motor is suitable. Group S ..... Centurion® SE “1081” • Up Rate • Low Service Factor. 3/4. 3450.
Pump Motors for Swimming Pools, Spas & Jetted Tubs Bulletin 1081/1082 Includes and identifies California California Energy Commission Compliant Motors

Formerly Formerly A. A. O. O. Smith Smith Publications Publications #1081 #1081 && #1082 #1082

A Deeper Pool of Resources

Statement of Warranty Policy All motors of A. O. Smith carry warranties. The nature and length of the warranty will depend upon the motor and are set forth below. Partial Motors. Partial motors are warranted against defect in materials and workmanship observed prior to any assembly of the motor parts by the Purchaser, provided that such claim is made within 30 days of its observation and no later than one year of the date A. O. Smith manufactured the partial motor. The company makes no warranty and disclaims all warranties as to latent defects. Pool Motors. Pool motors are warranted to be free of defects in workmanship and materials for a period of 24 months from the date of installation or 36 months from the date of manufacture. Whichever comes first. These motors must have the A. O. Smith two-compartment design or must be the 1081 designated ‘Centurion’ brand. Effective with motors manufactured in August 2004 and later, the warranty policy on motors will change to: Pool motors are warranted to be free of defects in workmanship and materials for a period of 12 months from the date of installation. If the customer does not have proof of date of installation, the warranty shall expire 24 months from the date of manufacture. Speed Engineered motors carry a two-year warranty from the date of manufacture and a one year warranty from date of installation.

Pool Motor Serial Number Introduction of a new standard date code was implemented in August of 2006 that will eventually be used on all A. O. Smith product. The first three characters represent the day of the year, the next two the year, and the last two the plant code. For example, 12306M, would mean the 123rd day of 2006 (12306) manufactured in A. O. Smith’s plant (4M). The first space is the plant code. The second letter is the month. And, the third and fourth spaces are the year. Example: “8A05” = Plant 8, January 2005 A. O. Smith Serial Number (Date Codes): 2000 is “00” G = July 2001 is “01” H = August 2002 is “02” I = September 2003 is “03” J = October 2004 is “04” K = November 2005 is “05” L = December A = January B = February C = March D = April E = May F = June

E-Plus motors carry a two-year warranty from the date of manufacture or one year from the date of installation. E-Plus 3 motors carry a three-year warranty from the date of manufacture or a two year warranty from the date of installation. All other A. O. Smith motors in this catalog are warranted to be free of defects in workmanship and materials for a period of 12 months from the date of installation. If the customer does not have proof of the date of installation, the warranty shall expire 24 months from the date of manufacture. This warranty is limited and shall be in lieu of any other warranties, expressed or implied, including but not limited to, any implied warranty or merchantability or fitness for a particular purpose. There are no other warranties that extend beyond the description of the face hereof. The liability of the Company arising out of its supply of said products, or their use, shall not in any case exceed the cost of correcting defects in the products as above set forth. The Company shall not be liable for any costs or damage incurred by its customers in the removal or replacement of defective products from units in which the products have been assembled. In no event shall the company be liable for loss of profits, indirect, consequential or incidental damages. This warranty does not apply if the failure is caused or contributed to by any of the following: improper handling, improper storage, improper installation, abuse, unsuitable application of the product, lack of reasonable and necessary maintenance, improper packaging for return, or repairs made or attempted by any other company, which in the judgement of the Company adversely affects the product’s performance or reliability. No products shall be returned to the Company without its prior consent and shall be properly packaged and shipped prepaid Point of Shipment, to the Company’s Authorized Service Center. The Company cannot assume responsibility or accept invoices for unauthorized repairs to its components, even though the motors may be defective. A. O. Smith reserves the right to change its warranty any time, effective as to motors changed after that date.

“CENTURY - CENTURION” The first two letters are “Year”; followed by number for month; and plant. Example: Ser: CA01-08 = 2005 January, Plant 8 Century Serial # (Date Code): 2000 = “BU” 2005 = “CA” 2001 = “BW” 2006 = “CB” 2002 = “BX” 2007 = “CC” 2003 = “BY” 2008 = “CD” 2004 = “BZ” 2009 = “CE” 01 - January 02 = February 03 = March 04 = April 05 = May 06 = June

07 = July 08 = August 09 = September 10 = October 11 = November 12 = December

Claims for After-market Replacement Motors go to: A. O. Smith Electrical Products Company Distribution Services Warranty at Dept. N-10 531 North Fourth Street Tipp City, OH 45371 OEM’s warranty their own products: Jacuzzi, Goulds, Hayward, Pentair/Purex, Polaris, Sta-Rite Please submit OEM warranty claims to the respective Original Equipment Manufacturer.

Contents Centurion Motor Replacement Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 Two Compartment Motor Replacement Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Two Compartment – C-Face Pool Filter Motors . . . . . . . . . . . . . . . . . . . . . . . . . . .5-7 Centurion – C-Face Pool Filter Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9 Two Compartment – Square Flange Pool Filter Motors . . . . . . . . . . . . . . . . . . .10-11 Centurion – Square Flange Pool Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-13 Above Ground – Pool, Flex 48 & Spa Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Two Compartment – Pool Sweep Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Sta-Rite Direct Replacement Spa Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Century – Three-Phase Swimming Pool Pump Motors . . . . . . . . . . . . . . . . . . . . . .16 Century – Pool Cleaner Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Century – Purex Direct Replacement Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Centurion – Three Phase Square Flange Pool & Spa Motors . . . . . . . . . . . . . . . . . .17 Century – Pentair/Pac Fab Direct Replacement Motors . . . . . . . . . . . . . . . . . . . . . .17 Century – Waterway Direct Replacement Motors . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Century – Hayward Northstar Direct Replacement Motors . . . . . . . . . . . . . . . . . . .18 Century – Close-Coupled Pump Motors: Three Phase Dripproof Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Three Phase Dripproof Rigid Base Motors . . . . . . . . . . . . . . . . . . . . . . . . .20 Three Phase Dripproof NEMA C-Face Motors . . . . . . . . . . . . . . . . . . . . . .20 Three Phase TEFC Rigid Base Motors . . . . . . . . . . . . . . . . . . . . . . . . . .21-22 Single Phase Dripproof Rigid Base Motors . . . . . . . . . . . . . . . . . . . . . . . . .23 Commercial Pump Motor Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Energy Savings Estimator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Inside Back Cover

Motor Efficiency

(Do not confuse amp draw with motor efficiency) Output Watts divided by Input Watts = Motor Efficiency When comparing motors of different configurations (ex: Permanent Split Capacitor to Capacitor Start-Capacitor Run) lower amps do not mean higher efficiency. Efficiency of the motor is determined as follows: Output Watts are defined as: 746 Watts equals 1 H.P. Multiply the nameplate H.P. times the nameplate Service Factor times 746 Watts to determine the maximum Output Watts. Contact the motor manufacturer for Input Watts. You'll need to supply the motor model number. Use the above formula to determine efficiency. Total efficiency of the system will also depend on pump efficiency and quality of the installation.

www.aosmithmotors.com

Cost to Operate

(Do not confuse amp draw with cost to operate) The formula to calculate the cost to operate an AC Single-phase Motor is: Cost = Volts x Amps x Power Factor x Rate x Usage 1000 Power Factor: Contact the motor manufacturer. You will need to supply the motor model number. Rate: Local utility charge per kilowatt hour. Usage: Hours motor is running (can be per day, per month or per year)

1

Centurion Pool & Spa Square Flange & C-face Replacement Guide Before using the Pool & Spa Motor Replacement Guide, you will need to know the horsepower (1), the service factor (2) of the original motor, and the name and/or the manufacturer of the pump on which the motor is used. The sample nameplate below shows the location of the horsepower and service factor.

Name of Pump OEM or Brand Name Group Americana, American Eagle . . . . . . . . . . . . . . . . . . . . . . . . . . A American Ultra-flow or Power Pump . . . . . . . . . . . . . . . . . . . . C Aqua Flo C-face . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Aqua Flo Dominator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A,B,C Arneson Pool Sweep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D Hayward Northstar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E Baker Hydro Hydron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Hayward Super Pump or Super Pump II . . . . . . . . . . . . . . . . . A Hayward Max-Flo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A ITT Marlow Argonaut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Jacuzzi Bros. Bronze . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Jacuzzi Bros. Cygnet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Jacuzzi Bros. Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Jacuzzi Bros. Magnum (E-Plus® columns only) . . . . . . . . . . . A Letro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D Pac Fab Challenger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Pac Fab Hydro Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Pac Fab Pinnacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Polaris Vac-Sweep PB4 Booster Pump . . . . . . . . . . . . . . . . . . D Premier/Springwater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Purex/ Hydrotech . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Purex Whisperflo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Sta-Rite Dura-Glas or Max-E-Glas . . . . . . . . . . . . . . . . . . . . . C Sta-Rite Dura-Glas II or Max-E-Glas II . . . . . . . . . . . . . . . . . . .C Speck Pumps, Models 90, 98, 423, 433, 21-80 . . . . . . . . . . . A Wet Institute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Two-speed and three-phase motors available for most applications. Contact your distributor or A. O. Smith Electrical Products Company for more details.

1

CE7-28

2 Find your pump brand, listed in alphabetical order at the right. Read across from the pump name and find the group of Century® catalog motors that will mechanically fit. These groups are labeled “A” through “E”. The service factor for each horsepower is shown in these groups below. Match the manufacturer of the pump, the horsepower, and the service factor and you will have a suitable replacement motor.

Group “A” C-face Threaded Shaft (56J) (Page 3-5)

Hp

1⁄ 3⁄2 4 1 11⁄2 2

21⁄2 3 4

Service Factor

Voltage

Centurion® Standard Efficiency Alum. Cat. No.

1.60 1.00 1.50 1.00 1.40 1.00 1.30 1.00 1.20 1.20 1.00 1.15 1.25

230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230 230 230 230

B126 B227SE B127 B228SE B128 B229SE B129 B230SE B836 B130 B231SE B131 —

E-Plus® Energy Efficient Alum. Cat. No.

B657 B657 B638 B638 B654 B654 B796 B796 — B809 B809 B818 B116

Group “C” Square Flange (Page 6-7) Neptune® Service Hp Factor

1⁄ 3 1⁄ 2 3⁄ 4 1 11⁄2

2 21⁄2 3

1.95 1.30 1.95 1.25 1.65 1.25 1.65 1.10 1.50 1.50 1.10 1.30 1.04 1.15

Group “B” C-face Keyed Shaft (56C) (Page 3-5)

Hp

1⁄ 2 3⁄ 4 1 1 1 ⁄2 2 3

2

Service Factor

1.60 1.50 1.40 1.30 1.20 1.20 1.15

Centurion® Standard Efficiency Alum. Voltage Cat. No.

230/115 230/115 230/115 230/115 230/115 230 230

B120 B121 B122 B123 B835 B124 B125

Voltage

230/115 23˜0/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230 230 230 230 208-230

Centurion® Standard E-Plus® Efficiency Energy Efficient Cat. No. Cat. No.

— B856 B846 B852 B847 B853 B848 B854 B858 B849 B855 B748 B840 ––

— — B845 — B661 — B841 — –– B842 — B843 — B844

Group “E” Northstar Hayward (Page 10)

Neptune® Standard Energy Efficiency EfficientService Hp Factor Cat. No. Cat. No.Voltage

3⁄ B879 4 1 B882 1 B880 1⁄ 1-B885 2 1⁄ 1-B881 2 2 B886 2 B883 3 B887 3— — — — — —

1.85 1.40 1.85 1.25 1.60 1.20 1.35 1.20 1.60

—208-230/115 —208-230/115 208-230/115 B872 208-230/115 B872 208-230/115 B873 208-230/115 B873 B874208-230 B874208-230 — 208-230

Cat. No.

SN1072 USN1102 SN1102 USN1152 SN1152 USN1202 SN1202 USN1302 SN1302

B875 B876 B877 B884 B878

Group “D” Pool Cleaner Replacement (Page 9) E-Plus® Energy Efficient Alum. Cast Iron Cat. No. Cat. No.

B656 B634 B653 B795 –– B808 B817

–– B631 B723 B750 –– B772 B774

Hp

3⁄ 4

Service Factor

Voltage

Shaft

Brand

Cat. No.

1.50 1.50 1.50 1.50 1.50

230/115 230/115 230/115 230/115 230/115

Threaded Threaded Threaded Threaded Threaded

Polaris Arneson Uniseal Arneson Uniseal Letro Letro

B625 B662 B663 B667 B668

www.aosmithmotors.com

Pool, Spa and Jetted Tubs Thru-Bolt Motor Replacement Guide To select the correct thru-bolt replacement motor, complete steps 1 through 4. 1.

2.

Is the manufacturer and model of your pump in the list of pump manufacturers and models below? If yes, the Century® motors from Group S and Group T in the tables below will fit your pump. Identify the maximum rated horsepower of your motor. Maximum Rated Hp = Horsepower (Hp) x Service Factor (SF)

Group S Single-speed (see page 8) Hp (Max. Rated)

Voltage

1⁄ 2 3⁄ 4 1 1 1 ⁄2 2

115 115 115 230/115 230/115

Pump Manufacturer & Model

Hp

Threads

Rotation

BV90

1.0

Right Hand

CW

BV91

1.0

Left Hand

CCW

3.

What is the voltage?

4.

Is the motor single- or two-speed? If single-speed select motor from Group S. If two-speed, select motor from Group T.

Group T Two-speed (see page 8) Cat. No. BN23SS BN24SS BN25SS BN35SS BN40SS

Group

American Products American II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Maxim “C” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Maxim “S” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Aqua Flo Flo-Master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Tub Master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S G/G Industries Olympian . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Gruber Dura-Flo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Hayward Mfg. Power Flo 1500 Series . . . . . . . . . . . . . . . . . . . . . . . . . S Power Flo II 1700 Series . . . . . . . . . . . . . . . . . . . . . . . . S Power Flo II 1900 Series . . . . . . . . . . . . . . . . . . . . . . . . S Power Flo UN Series . . . . . . . . . . . . . . . . . . . . . . . S or T Power Flo UN-LX Series . . . . . . . . . . . . . . . . . . . . S or T Power Flo II UN Series . . . . . . . . . . . . . . . . . . . . . . . . . T Power Flo 1900SD Series . . . . . . . . . . . . . . . . . . . . . . . S Hoffinger, Doughboy and Lomart Cat. No.

Replacement motor horsepower must be equal to or greater than maximum rated horsepower.

Replaces Hoffinger #

300-1028 (1 Hp) 300-1027 (3⁄4 Hp) 300-1043 (1 Hp) 300-1017 (3⁄4 Hp)

Jacuzzi Bros. Inno-Tech J Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . S JCM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Vector LVL Series* . . . . . . . . . . . . . . . . . . . . . . . . . . . . S

Hp (Max. Rated)

Voltage

Cat. No.

3⁄ /.10 4 1/.12 1/.16 11⁄2/.25 11⁄2/.18 11⁄2/.18 2 /.25 2 /.25

115 115 115 115 115 230 230 230

BN36 BN37 BN38 BN50 BN60 BN34 BN51 BN61

Pump Manufacturer & Model

Group

Jacuzzi Bros. (continued) LTVL Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T SLR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S LRDV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S LCU Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T LTCU Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T LCM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S LTCM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T PAC-FAB Dynamo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Dynamite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Premier/Springwater 220-225-255 MKii Series . . . . . . . . . . . . . . . . . . . S or T 300, 320, 325, 355 Series . . . . . . . . . . . . . . . . . . . . . . S Speck Model E90 and E91 . . . . . . . . . . . . . . . . . . . . . . . S or T Sta-Rite Dura-Jet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S or T Vico/Ultra-Jet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Ultra Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Waterway Bath Pump Self Drain . . . . . . . . . . . . . . . . . . . . . . . . . . S Hi-Flo Side Discharge . . . . . . . . . . . . . . . . . . . . . . S or T Hi-Flo Center Discharge . . . . . . . . . . . . . . . . . . . . S or T SVL56 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C Super Flo Side Discharge . . . . . . . . . . . . . . . . . . .S or T Workhorse Side Discharge . . . . . . . . . . . . . . . . . . .S or T

Note: * Pump rated for 115/230 Volt, check voltage supply to ensure replacement motor is suitable.

www.aosmithmotors.com

3

A.O. Smith Two Compartment to Motor Replacement Guide Name of Pump OEM or Brand Name Group Class Americana, American Eagle . . . . . . . . . . . . . . . . . . . . . ST American Ultra Flow or Power Pump . . . . . . . . . . . . . .SQ Aqua-Flo C-Face . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SK Aqua-Flo Dominator . . . . . . . . . . . . . . . . . . . . . . . . . . .SQ Arneson Pool Sweep . . . . . . . . . . . . . . . . . . . . . . . . . .SP Hayward Super & Super II . . . . . . . . . . . . . . . . . . . . . .ST Hayward Max-Flo . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ST Hydrotech . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ST ITT Marlow Argonaut . . . . . . . . . . . . . . . . . . . . . . . . . .ST Jacuzzi Bronze, Plastic . . . . . . . . . . . . . . . . . . . . . . . . .SK Jacuzzi Magnum . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ST Pac Fab Challenger . . . . . . . . . . . . . . . . . . . . . . . . . . .SQ Pac Fab Hydro Pump . . . . . . . . . . . . . . . . . . . . . . . . . .SK Premier/Springwater . . . . . . . . . . . . . . . . . . . . . . . . . . .SK Starite Duraglas or Maxiglas . . . . . . . . . . . . . . . . . . . . .SQ Speck . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ST Wet Institute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SK

Group “SK”

Group “SQ”

Group “ST”

Hp

Service Factor

Voltage

Stock Number

1/2 1/2 3/4 3/4 1 1 1-1/2 1-1/2 2 2 2-1/2 3

1.9 1.3 1.65 1.27 1.65 1.25 1.47 1.1 1.3 1.1 1.0 1.15

115/230 115/230 115/230 115/230 115/230 115/230 208-230 115/230 230 208-230 230 230

SQ1052 USQ1052 SQ1072 USQ1072 SQ1102 USQ1102 SQ1152 USQ1152 SQ1202 USQ1202 USQ1252 SQ1302

Hp

Service Factor

Voltage

Stock Number

Conservationist

1/2 3/4 1 1.5 2 3

1.6 1.5 1.5 1.3 1.3 1.115

115/230 115/230 115/230 115/230 230 230

SK1052 SK1072 SK1102 SK1152 SK1202 SK1302

CK1052 CK1072 CK1102 SK1152 SK1202 SK1302

Group “SP” Hp

Voltage

Brand

Stock Number

3/4 3/4

115/230 115/230

Arneson Arneson

SPS1052 RPS1052

Conservationist

Hp

Service Factor

Voltage

Stock Number

QC1052

1/2 3/4 3/4 1 1 1-1/2 1-1/2 2 2 2-1/2 3

1.6 1.5 1.0 1.5 1.0 1.3 1.0 1.3 1.0 1.0 1.15

115/230 115/230 115/230 115/230 115/230 115/230 115/230 230 115/230 230 230

ST1052 ST1072 UST1072 ST1102 UST1102 ST1152 UST1152 ST1202 UST1202 UST1252 ST1302

QC1072 UQC1072 QC1102 UQC1102 SQ1152 UQC1152 SQ1202 USQ1202 USQ1252 SQ1302

Above Ground and Spa Applications Hp

Service Factor

Voltage

Stock Number

1/2 3/4•1/8 3/4 1•1/6 1

1.0 1.0 1.0 1.0 1.0

115 115 115 115 115

BN23SS BN36* BN24SS BN37* BN25SS

Conservationist

CT1052 CT1072 CT1012 ST1152 ST1202

ST1302

Please Note: Every effort has been made to ensure the accuracy of this guide. A.O. Smith cannot, however, accept responsibility for ultimate selection. OEM design changes and variations from one OEM to another may result in different construction, dimensions or operating characteristics. It is your responsibility to confirm the acceptability of the suggested replacement.

Notes: *2 Speed Please contact your local distributor with motor model number, frame size, horsepower, service factor, voltage and pump OEM model number for proper spa or above ground motor identification.

4

www.aosmithmotors.com

Two Compartment NEMA C-Face Pool Filter Motors • Single Speed Important: Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced

Features

Features: • Auto Protector • Capacitor Start and Capacitor StartImportant: Run Total •output (HP x service of replacement motor must equal or exceed motor being replaced Capacitor NEMA “56C” Facefactor) Mount • Not Reversible • Open Drip Proof • Rotation (CCWPE) • Sealed Ball Bearings •• Sealed Switch Design • •“1081” Design • 50° C Ambient • 60 HZ All Copper Not Reversible • “1081” Design • 303 Stainless Shaft (56J &• 56C) 304Proof Brg. Shaft End Windings Open•Drip • 50° C Ambient • Auto Protector • Capacitor Start • NEMA “56C” Face Mount

• Rotation (CCWPE) • Sealed Ball Bearings • Sealed Switch Design

• 60 HZ • 303 Stainless Shaft (56J & 56C) • 304 Brg. Shaft End

CT1072

SK1072

HIGH SERVICE FACTOR (FULL RATED)- STANDARD EFFICIENCY AND “CONSERVATIONIST” HIGH EFFICIENCY DESIGNS HP

RPM

Volts

Max. Amps

Service Factor

Frame

Stock Number

Shaft

Approx. “AG”

1/2

3450

115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/208-230 230 208-230 230 208-230

10.6/5.3 8.0/4.0 11.0/5.5 8.0/4.0 14.6/7.3 11.0/5.5 15.0/7.5 11.0/5.5 17.0/8.5 13.6/6.8 18.6/9.3 18.6/9.3 13.6/6.8 19.4/9.7 19.6/10.4-9.8 11.2 12.6-11.4 14.4 14.5-13.8

1.6 1.6 1.6 1.6 1.5 1.5 1.5 1.5 1.5 1.4 1.5 1.5 1.4 1.3 1.5 1.3 1.3 1.15 1.15

56C 56C 56J 56J 56C 56C 56J 56J 56C 56C 56J 56J 56J 56C 56J 56C 56J 56C 56J

SK1052 CK1052 ★ ST1052 CT1052 ★ SK1072 CK1072 ▲ ST1072 CT1072 ▲ SK1102 CK1102 ▲ ST1102 STE1102 CT1102 ▲ SK1152 ▲ ST1152 ▲ SK1202 ▲ ST1202 ▲ SK1302 ▲ ST1302 ▲

Key Key Thd. Thd. Key Key Thd. Thd. Key Key Thd. Thd. Thd. Key Thd. Key Thd Key Thd.

11 11 10-5/8 11 11-9/16 11-11/16 11 11-11/16 12-1/8 12-1/8 12-1/8 12-1/8 12-1/8 12-5/8 12-5/8 13-1/16 13-1/16 13-5/8 14-3/16

3/4

1

3450

3450

1-1/2

3450

2

3450

3

3450

Notes 20

$

20

$

20

$

20

$

20

$

351 20 20 20 20 20 20 20

$ $ $ $ $ $ $

Notes: 20. $ Energy Efficient capacitor start, capacitor run “Conservationist” motor 351. eMod™ equipped motor See page 258 for mounting dimensions. eMod® motors on this page pass ASME A112.19.17 SVRS standard. eMod® will not prevent evisceration, hair, object or partial limb entrapment and is designed for suction lift applications. ▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov

www.aosmithmotors.com

5

Two Compartment NEMA C-Face Pool Filter Motors • Single Speed Important: Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced Features Features: • Auto Protector • Capacitor Start • NEMA “56C” Face Mount Total output (HP xDrip service factor) of replacement or exceed motor being replaced •Important: Not Reversible • Open Proof • Rotation (CCW motor Pumpmust End) equal • Sealed Ball Bearings • Sealed Switch Design • “1081” Design • 50° C Ambient • 60 HZ • 303 Stainless Shaft • • • •

All Copper Windings Auto Protector Capacitor Start NEMA “56C” Face Mount

• Not Reversible • Open Drip Proof • Rotation (CCW Pump End) • Sealed Ball Bearings

• Sealed Switch Design • “1081” Design • 50° C Ambient

• 60 HZ • 303 Stainless Shaft • 304 Brg. Shaft End

UST1072

LOW SERVICE FACTOR (UP-RATED) - STANDARD EFFICIENCY AND “CONSERVATIONIST” HIGH EFFICIENCY DESIGNS HP

RPM

Volts

Max. Amps

Service Factor

Frame

Stock Number

Shaft

Approx. “AG”

3/4

3450

115/230

11.0/5.5

1.0

56J

UST1072

Thd.

10-5/8

1

3450

1.0 1.1 1.1 1.0 1.0 1.0 1.0 1.1 1.1

56J 56J 56J 56J 56J 56J 56J 56J 56J

UCT1072 ★ UST1102 USTE1102 UCT1102 ▲ UST1152 USTE1152 UCT1152 ▲ UST1202 ▲ UST1252 ▲

Thd. Thd. Thd. Thd. Thd. Thd. Thd. Thd. Thd.

11 11 11 11-11/16 12-1/8 12-1/8 12-1/8 12-5/8 13-1/16

1-1/2

2 2-1/2

3450

3450 3450

115/230 8.0/4.0 115/230 15.0/7.5 115/230 15.0/7.5 115/230 11.0/5.5 115/230 18.6/9.3 115/230 18.6/9.3 115/230 14.6/7.3 115/208-230 19.6/10.4-9.8 208-230 12.6/11.4

Notes 20

$

351 20

$

351 20 20 20

$ $ $

Note: 20 $ Energy Efficient capacitor start, capacitor run “Conservationist” motor 351. eMod™ equipped motor eMod® motors on this page pass ASME A112.19.17 SVRS standard. eMod® will not prevent evisceration, hair, object or partial limb entrapment and is designed for suction lift applications. ▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov

6

www.aosmithmotors.com

Two Compartment NEMA C-Face Pool Filter Motors • Two Speed Important: Features Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced Features: Auto output Protector Capacitor Start • Stainless motor Steel Threaded Important: Total (HP •x service factor) of replacement must equalShaft or exceed motor being replaced • Not Reversible • Open Drip Proof • Rotation (CCW Pump End) • Sealed Ball Bearings (304 Shaft End) • Sealed Switch Design • “1081” Design •• Sealed 40° C Ambient • 60 • Auto Protector • Not Reversible Ball • HZ “1081” Design • Capacitor Start • Open Drip Proof Bearings (304 • 50° C Ambient A.O. Smith NEMA C flange swimming pool filter pump motors are carefully engineered to meet the rugged demands of pool duty. Two sealed ball bearings (with large 304 bearing on shaft end) offer ample capacity for extended life. Bearings are selected for quietness and are lubricated for life with greases specifically chosen for moisture and heat resistant qualities. Aluminum end frames are accurately machined for maximum concentricity and minimum runout.

STS1072R

Two-speed motors are shipped less hi/lo switch for remote operation. End cover and switch assembly kit number 615332 available and sold separately.

HP 3/4~1/8 1~1/6 1-1/2~1/4 2~1/3

RPM 3450/1725 3450/1725 3450/1725 3450/1725

Volts 230 230 230 230

Max. Amps Hi - Lo 6.4/1.9 8.5/2.5 9.0/3.3 11.4/4.1

Service Factor 1.5 1.5 1.3 1.2

Frame 56J 56J 56J 56J

Stock Number STS1072R STS1102R STS1152R STS1202R

★ ★ ★ ★

Shaft Thrd Thrd Thrd Thrd

Approx. “AG” 12-1/8 13-1/16 13-1/16 13-3/4

Notes 90 20 20

$ $ $ $

★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov

NEMA C-Face 3-Phase Pump Motors Features: Ball Bearings • Continuous Duty • Internal Junction Box • Keyed and Stainless Steel Threaded Shafts • NEMA “56C” Mount • Open Drip Proof • 40° C Ambient • 60 HZ • 208-230/460V T3052

NEMA C Face mounting bracket, and end frames are die-cast corrosion resistant aluminum, accurately machined for maximum concentricity, and minimum runout. Stator assemblies are press fitted into rolled steel main frames. Double shielded ball bearings, selected for quiet operation, are lubricated for life with greases specifically chosen for moisture and heat resistant qualities. 1/2" x 14 thread tapped opening is provided for conduit fitting. No external junction box required connections made under motor canopy. Motors are supplied with horizontal canopy but are easily converted for vertical operation with the use of optional vertical canopy (call Customer Service for more information). HP 1/2 3/4

RPM 3450 3450

1

3450

1-1/2

3450

2

3450

3

3450

Volts 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 230/460 230/460

Max. Amps 2.7/1.35 3.4/1.7 3.4/1.7 4.0/2.0 4.0/2.0 6.8/3.4 6.8/3.4 8.6/4.3 8.6/4.3 9.0/4.5 9.0/4.5

Service Factor 1.6 1.5 1.5 1.4 1.4 1.3 1.3 1.2 1.2 1.15 1.15

Frame 56J 56C 56J 56C 56J 56C 56J 56C 56J 56C 56J

Stock Number T3052 K3072 T3072 K3102 T3102 K3152 T3152 K3202 T3202 K3302 T3302

Shaft Thrd Key Thrd Key Thrd Key Thrd Key Thrd Key Thrd

Protector None None None None None None None None None None None

Approx. “AG” 8-5/8 9-1/8 9-1/8 9-11/16 9-11/16 11-5/16 11-5/16 11-5/16 11-5/16 11-7/16 11-7/8

Notes

1 1

Notes: 1. Item to be discontinued when stock is depleted 20. $ Energy Efficient capacitor start, capacitor run “Conservationist” motor 90. 50 degree C ambient See page 258 for mounting dimensions.

www.aosmithmotors.com

7

Centurion® C-Face Pool and Spa Pump Motors Permanent Split Capacitor • Switchless • Single Phase • Dripproof • No Base • 3450 RPM 1/2 thru 4 HP B126

Features: Ball Bearing • 50°C Ambient • 60 Hz • Class B Insulated • Rotation (CCW Pump End) • 304 Bearing Shaft End

Centurion® “1081” • Full Rate • High Service Factor • Aluminum NEMA “C” Brackets HP

RPM

Volts

Service Factor Amps

1/2

3450

3/4

3450

1

3450

230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230/115 230 230/115 230 230 230 208-230

4.4/8.8 4.4/8.8 6.0/12.0 6.0/12.0 7.2/14.4 7.2/14.4 7.2/14.4 9.2/18.4 9.2/18.4 9.2/18.4 10.8/21.6 10.5 10.8/21.6 10.5 14.1 14.1 21.0-19.4

1-1/2

2

3450

3450

3

3450

4

3450

Service Factor

Frame

1.60 1.60 1.50 1.50 1.40 1.40 1.40 1.30 1.30 1.30 1.20 1.20 1.20 1.20 1.15 1.15 1.25

56C 56J 56C 56J 56C 56J 56J 56C 56J 56J 56C 56C 56J 56J 56C 56J 56Y

Stock Number

B120 ★ B126 ★ B121 ▲ B127 ▲ B122 ▲ B128 ▲ BE128 ▲ B123 ▲ B129 ▲ BE129 ▲ B835 ▲ B124 ▲ B836 ▲ B130 ▲ B125 ▲ B131 ▲ B116 ▲

Overload Protector

Shaft

"C" Dimension

Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Manual

Keyed Threaded Keyed Threaded Keyed Threaded Threaded Keyed Threaded Threaded Keyed Keyed Threaded Threaded Keyed Threaded Special

11.44 11.94 11.44 12.01 11.89 12.14 12.45 13.19 13.50 13.50 13.94 12.55 13.90 13.10 13.65 14.15 16.78

12 31,34,63,236

Overload Protector

Shaft

"C" Dimension

Notes

Notes

12 12 12 12,351 12 12,351

12 12

Centurion® SE “1081” • Up Rate • Low Service Factor HP

3/4 1 1-1/2 2 2-1/2

RPM

Volts

3450 3450 3450 3450 3450

230/115 230/115 230/115 230/115 230

Service Factor Amps

4.4/8.8 6.0/12.0 7.2/14.4 9.2/18.4 10.5

Service Factor

1.00 1.00 1.00 1.00 1.00

Frame

56J 56J 56J 56J 56J

Stock Number

B227SE ★ B228SE ▲ B229SE ▲ B230SE ▲ B231SE ▲

Auto Auto Auto Auto Auto

Notes:

Threaded Threaded Threaded Threaded Threaded

12.56 12.81 13.91 14.31 13.81

12 12 12 12 12

Continues on next page

12. 303 Stainless steel shaft 31. 40 degree C ambient 34. Rigid base 63. Speck Pump replacement motor 236. CCW Rotation facing opposite shaft end 351. eMod™ equipped motor eMod® motors on this page pass ASME A112.19.17 SVRS standard. eMod® will not prevent evisceration, hair, object or partial limb entrapment and is designed for suction lift applications. ▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov

8

www.aosmithmotors.com

Centurion® C-Face Pool and Spa Pump Motors

Continued from previous page

Permanent Split Capacitor • Switchless • Single Phase • Dripproof • No Base • 3600 & 3600/1800 RPM 1/2 thru 3 HP Features: Ball Bearing • 304 BRG Shaft End • 60 Hz • Class B Insulated • Rotation (CCW Pump End) • $ Energy Efficient

B971

E-Plus® Energy Efficient “1081” • Centurion® • Full Rate • Aluminum NEMA “C” Brackets • 50˚C Ambient HP

RPM

1/2

3450

3/4

3450

1

3450

1-1/2

3450

2

3450

3

3450

Service Factor Amps

Volts

208-230/115 208-230/115 208-230/115 208-230/115 208-230/115 208-230/115 208-230/115 208-230/115 208-230 208-230 208-230 208-230

4.0-3.7/7.4 4.0-3.7/7.4 5.4-5.0/10.0 5.4-5.0/10.0 6.4-5.9/11.8 6.4-5.9/11.8 8.7-7.8/15.6 8.7-7.8/15.6 10.4-9.6 10.4-9.6 15.0-13.6 15.0-13.6

Service Factor

1.60 1.60 1.50 1.50 1.40 1.40 1.30 1.30 1.20 1.20 1.15 1.15

Frame

56C 56J 56C 56J 56C 56J 56C 56J 56C 56J 56C 56J

Stock Number

B656 ★ B657 ★ B634 B638 B653 B654 B795 B796 B808 B809 B817 B818

▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲

Overload Protector

Shaft

"C" Dimension

Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto

Keyed Threaded Keyed Threaded Keyed Threaded Keyed Threaded Keyed Threaded Keyed Threaded

11.51 11.95 12.19 12.69 12.55 13.19 13.19 13.55 13.65 14.15 13.65 14.15

Notes

$ $ $ $ $ $ $ $ $ $ $ $

12 12 12 12 12 12

Two Speed “1081” • Full Rate • High Service Factor • 40°C Ambient HP

RPM

Service Factor Amps

Volts

Service Factor

Frame

Stock Number

Overload Protector

Shaft

"C" Dimension

Notes

High Speed Switchless, Low Speed Microswitch • Aluminum “C” Bracket • Hi-Lo Toggle Switch available (P/N 17590450) 3450/1725

1/2~.06 3/4 ~.10

3450/1725

1~.12

3450/1725

1-1/2~.20

3450/1725

2~.25

3450/1725

3~.38

3450/1725

115 115 115 115 230 230 230 230 115 230 230 230

8.8/3.55 8.8/3.55 11.2/5.0 11.2/5.0 6.3/2.3 6.3/2.3 8.9/3.1 8.9/3.1 14.6/4.4 10.6/3.2 10.6/3.2 13.8/4.0

1.60 1.60 1.50 1.50 1.40 1.40 1.30 1.30 1.10 1.20 1.20 1.15

56C 56J 56C 56J 56C 56J 56C 56J 56J 56C 56J 56J

B970 B971 B972 B973 B974 B975 B976 B977 B969 B978 B979 B966

★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★

Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto

Keyed Threaded Keyed Threaded Keyed Threaded Keyed Threaded Threaded Keyed Threaded Threaded

11.80 12.30 11.80 12.30 12.05 13.05 12.54 13.05 13.54 13.04 13.55 14.29

12 12 12 12 12,63,90 12 12

E-Plus® Energy Efficient “1081” • Centurion® • Full Rate • Cast Iron NEMA “C” Brackets • 50˚C Ambient HP

RPM

Volts

Service Factor Amps

Service Factor

Frame

3/4 1 1-1/2 2 3

3450 3450 3450 3450 3450

208-230/115 208-230/115 208-230/115 208-230 208-230

5.4-5.0/10.0 6.4-5.9/11.8 8.7-7.8/15.6 10.4-9.6 15.0-13.6

1.50 1.40 1.30 1.20 1.15

56C 56C 56C 56C 56C

Stock Number

B631 B723 B750 B772 B774

▲ ▲ ▲ ▲ ▲

Overload Protector

Shaft

"C" Dimension

Notes

Auto Auto Auto Auto Auto

Keyed Keyed Keyed Keyed Keyed

12.62 12.80 13.30 14.05 14.05

12 12 12 12 12

$ $ $ $ $

Notes: 12. 303 Stainless steel shaft 63. Speck Pump replacement motor 90. 50 degree C ambient ▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov

www.aosmithmotors.com

9

Two Compartment Square Flange Pool Filter Motors Single Speed & Energy Efficient Important: Features Total output (HP x service factor) of replacement motor must equal or exceed motor being replaced Used on many Red Jacket, Pac Fab, American motor Products Important: Total Sta-Rite, output (HP x service factor) of replacement must equal or exceed motor being replaced and Sears Jet and Pool Pumps Used on many Sta-Rite, Red Jacket, Pac Fab, American Products and Sears Jet and Pool Pumps

Features: • Auto Protector • Capacitor Start •• High Service Factors • Open Drip ProofFactors All Copper Winding • High Service • Stainless Steel •- Rotation (CCW Pump End)50° • C303 Stainless Steel Threaded Shaft • Ambient •• Sealed Ball Bearings • 50° C Ambient • 60 HZ Auto Protector • Open Drip Proof 303 Threaded Shaft

SQ1032

SQ1152

• 60 HZ • Capacitor Start1

HIGH SERVICE FACTOR (FULL RATED) HP

RPM

Volts

Max. Amps

Service Factor

Frame

Stock Number

Approx. “AG”

1/3 1/2

3450 3450

3/4

3450

1

3450

1-1/2 2

3450 3450

115/230 115/230 115/230 115/230 115/230 115/230 115/208-230 230 230

9.9/5.0 13.4/6.7 9.6/4.8 15.3/7.6 12.6/6.3 19.2/9.6 16.0/8.0 10.4 11.2

1.95 1.9 1.9 1.65 1.65 1.65 1.65 1.47 1.3

48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y

SQ1032 SQ1052 QC1052 SQ1072 QC1072 SQ1102 QC1102 SQ1152 SQ1202

11-1/8 11-1/2 10-7/8 12-1/8 11-1/4 13-1/8 11-7/8 13-1/4 13-7/8

3

3450

230

15.4

1.15

56Y

SQ1302 ▲

Service Factor 1.3 1.27 1.27 1.27 1.25 1.25 1.25 1.1 1.1 1.1 1.1 1.0

Frame 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y 48Y

★ ▲ ▲ ▲ ▲

14

Notes

20

$

20

$

20 20 20 20

$ $ $ $

LOW SERVICE FACTOR (UP-RATED) HP 1/2 3/4

1

1-1/2

2 2-1/2

RPM 3450 3450

3450

3450

3450 3450

Volts 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 230 230

Max. Amps 9.9/5.0 13.4/6.7 11.8/5.9 9.6/4.8 15.3/7.6 12.6/6.3 14.8/7.4 19.2/9.6 19.2/9.6 16.0/8.0 10.4 11.2

Stock Number USQ1052 USQ1072 USQE1072 UQC1072 USQ1102 UQC1102 USQE1102 USQ1152 USQE1152 UQC1152 USQ1202 USQ1252

★ ▲

▲ ▲ ▲

Approx. “AG” 11-1/8 11-1/2 11-1/2 10-7/8 12-1/8 11-1/4 12-1/8 13-1/8 13-1/8 13-1/4 13-1/4 13-7/8

Notes

351 20 20 351 351 20 20 20

$ $

$ $ $

Notes: 20. $ Energy Efficient capacitor start, capacitor run “Conservationist” motor 351. eMod™ equipped motor See page 258 for mounting dimensions. eMod® motors on this page pass ASME A112.19.17 SVRS standard. eMod® will not prevent evisceration, hair, object or partial limb entrapment and is designed for suction lift applications. ▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov

10

www.aosmithmotors.com

Two Compartment Square Flange Pool Motors • Two Speed vFeatures Total output (HP x Service Factor) of replacement motor must Important: equal or exceed motor being replaced. Important: Total output (HP x Service Factor) of replacement motor must equal or exce Used on many Sta-Rite, Red Jacket, and Sears Jet and Pool Pumps.

Features: All Copper Windings • Auto Protector - Single Phase Used on many Sta-Rite, Red Jacket, and Sears Jet and Pool Pumps. • Open Drip Proof • Rotation (CCW Pump End) All Copper Windings • Shaft Open •Drip Proof • HZ Stinless Steel - (303) •• 303 Stainless Steel Threaded 50° C Ambient • 60 Auto Protector • Rotation (CCW PSC PumpHigh Speed Threaded Shaft •• Energy Efficient-1ø Capacitor Start Low Speed, • Capacitor Start1 End) • 50° C Ambient • 60 HZ Two-speed motors are shipped less hi/lo switch for remote operation. End cover and switch assembly kit number 615332-001 available and sold separately.

SQS1072R

SQS1152R

HIGH SERVICE FACTOR (FULL RATED) HP 3/4 ~1/8

RPM

Volts

Amps Hi - Lo

S.F.

Frame

Stock Number

3450/1725

115 230 230 230 230

13.0/4.2 6.1/2.1 9.5/2.5 10.0/3.0 11.3/3.3

1.65 1.60 1.65 1.47 1.3

48Y 48Y 48Y 48Y 48Y

SQL1072R SQS1072R SQS1102R SQS1152R SQS1202R

Stock Number

1~1/6 3450/1725 1-1/2~1/4 3450/1725 2~1/3 3450/1725

Approx. “AG” ★ ★ ★ ★ ★

Notes

$ $ $ $ $

12-5/8 12-5/8 13-13/16 13-9/16 13-13/16

LOW SERVICE FACTOR (UP-RATED) RPM

Volts

Amps Hi - Lo

S.F.

Frame

3450/1725

230

6.1/2.1

1.25

48Y

UQS1102R ★

12-5/8

$

1-1/2~1/4 3450/1725 2~1/3 3450/1725

230 230

9.5/2.5 10.0/3.0

1.1 1.1

48Y 48Y

UQS1152R ★ UQS1202R ★

13-13/16 13-9/16

$ $

HP 1~1/6

Approx. “AG”

Notes

Three Phase Square Flange Pump Motors Features • All Copper Windings • Stainless Steel • 50° C Ambient Features: All Copper Windings • Open Drip Proof • 303 Stainless Steel Threaded Shaft • Open Drip Proof (303) Threaded Shaft • 60 HZ • Sealed Ball Bearings • 50° C Ambient • 60 HZ • Sealed Ball Bearings HP

RPM

Volts

Max. Amps

1/2 3/4 1 1-1/2 2 3

3450 3450 3450 3450 3450 3450

208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 200-230/460

3.0/1.5 3.6/1.8 4.7/2.35 6.8/3.4 8.5/4.25 9.7/4.9

Service Factor

Frame

1.9 1.65 1.65 1.47 1.3 1.15

48Y 48Y 48Y 48Y 48Y 56Y

Stock Number Q3052 Q3072 Q3102 Q3152 Q3202 Q3302

Q3052

Overload Protector

Approx. “AG”

Notes

None None None None None None

9-7/8 10-3/8 10-7/8 11-7/8 12-5/8 12

31

Note: 31. 40 degree C ambient See page 258 for mounting dimensions. ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov

For fast, knowledgeable customer service and technical help for pool motors, call our toll free number: 1-866-887-5216.

www.aosmithmotors.com

11

Centurion® Pool and Spa Pump Motors Square Flange Permanent Split Capacitor • Switchless • Single Phase • Dripproof • No Base • 3600 and 3600/1800 RPM • 1/2 thru 3 HP Features: Ball bearing • 60 Hz • 50°C Ambient • Class B Insulated • Rotation (CCW Pump End) • Stainless Steel Shafts • $ Energy Efficient Applications: Replacement motor for Sta-Rite, HydroTech, Premier, AquaFlo, Red Jacket, Sears and Pac Fab/Pentair brand pumps. Can be used on Sta-Rite, Red Jacket and Sears home water systems. HP

RPM

Volts

Service Factor Amps

Service Factor

Centurion “1081” • Full Rate • High Service Factor 1⁄2 3450 230/115 5.4/10.8 1.95 3⁄4 3450 230/115 7.1/14.2 1.65 230/115 7.1/14.2 1.65 1 3450 230/115 8.0/16.0 1.65 230/115 8.0/16.0 1.65 1-1⁄2 3450 230/115 10.5/21.0 1.50 230 10.0 1.50 2 3450 230 11.5 1.30 Centurion® “1081” • Up-Rate • Low Service Factor 1⁄2 3450 230/115 4.0/8.0 1.30 3⁄4 3450 230/115 5.4/10.8 1.25 1 3450 230/115 7.1/14.2 1.25 230/115 7.1/14.2 1.25 1-1⁄2 3450 230/115 8.0/16.0 1.10 230/115 8.0/16.0 1.10 2 3450 230/115 11.2/22.4 1.10 230 10.0 1.10 230 10.0 1.10 2-1⁄2 3450 230 11.5 1.04 Centurion® II “1081” • Up-Rate • Low Service Factor 1⁄2 3450 230/115 3.6/7.2 1.30 E-Plus® Energy Efficient “1081” • Centurion • Full Rate 1⁄2 3450 208-230/115 4.5-4.4/8.8 1.90 3⁄4 3450 208-230/115 6.0-5.6/11.2 1.67 208-230/115 6.0-5.6/11.2 1.67 1 3450 208-230/115 7.8-7.4/14.8 1.65 7.8-7.4/14.8 208-230/115 1.65 1-1⁄2 3450 208-230 9.6-8.8 1.47 208-230 9.6-8.8 1.47 2 3450 208-230 11.0-10.0 1.30 208-230 11.0-10.0 1.30 3 3450 208-230 15.0-13.6 1.15 208-230 15.0-13.6 1.15

Frame

Stock Number

56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y

B846 B847 B847A B848 BE848 B858 B849 B748



56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y

B856 B852 B853 BE853 B854 BE854 B859 B855 BE855 B840



48Y

B856SM ★

56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y 56Y

B845 B661 B661A B841 B841A B842 B842A B843 B843A B844 B844A

B852

Shaft

Overload Protector

“C” Dim.

Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded

Auto Auto Auto Auto Auto Auto Auto Auto

12.44 12.44 12.44 12.81 12.87 14.44 13.44 13.44

Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded

Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto

12.44 12.44 12.44 12.44 12.82 12.77 14.44 13.44 13.39 13.44

Threaded

Auto

12.33

Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded Threaded

Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto

12.44 13.19 13.19 13.44 13.44 13.94 13.94 14.44 14.44 14.44 14.44

Notes

®

▲ ▲ ▲ ▲ ▲ ▲ ▲

★ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲

★ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲

352 351

351 351

351

1,158,235

$ $ 352 352 352 352 352

$ $ $ $ $ $ $ $ $

Notes: 1. Item to be discontinued when present stock is depleted 107. Uprated – Low Service Factor 158. Open motor construction, overload protector mounted at 12 o'clock 235. Centurion II motors are switchless. Designed in a 48-frame shell diameter that is .80 inches smaller in diameter than the 56-frame Centurion and Centurion SE designs. 351. eMod™ equipped motor 352. Pentair, almond paint, direct replacement motor eMod® motors on this page pass ASME A112.19.17 SVRS standard. eMod® will not prevent evisceration, hair, object or partial limb entrapment and is designed for suction lift applications. ▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov

For fast, knowledgeable customer service and technical help for pool motors, call our toll free number: 1-866-887-5216.

12

www.aosmithmotors.com

Centurion® Pool and Spa Pump Motors Square Flange Permanent Split Capacitor • Switchless • Single Phase • Dripproof • No Base • 3600 and 3600/1800 RPM • 1/2 thru 3 HP Features: Ball bearing • 60 Hz • 50°C Ambient • Class B Insulated • Rotation (CCW Pump End) • Stainless Steel Shafts • $ Energy Efficient Applications: Replacement motor for Sta-Rite, HydroTech, Premier, AquaFlo, Red Jacket, Sears and Pac Fab/Pentair brand pumps. Can be used on Sta-Rite, Red Jacket and Sears home water systems. HP

RPM

Volts

Service Factor Amps

Service Factor

Frame

Stock Number

Shaft

B852 Overload Protector

E-Plus® Energy Efficient “1081” • Centurion SE • Up-Rate 3⁄4 3450 208-230/115 4.5-4.4/8.8 1.25 56Y B862SE ★ Threaded Auto 1 3450 208-230/115 6.0-5.6/11.2 1.25 56Y B863SE ▲ Threaded Auto 1-1⁄2 3450 208-230/115 7.8-7.4/14.8 1.10 56Y B864SE ▲ Threaded Auto 2 3450 208-230 9.6-8.8 1.10 56Y B865SE ▲ Threaded Auto 2-1⁄2 3450 208-230 11 .0-10.0 1.04 56Y B866SE ▲ Threaded Auto Two Speed “1081” • Full Rate • High Service Factor • 40°C Ambient High Speed Switchless, Low Speed Microswitch • Square Flange • Hi-Lo Toggle Switch Assembly Available (Part # 17590450) .75~.12 3450/1725 230 6.0/2.3 1.67 56Y B980 ★ Threaded Auto . 75~.12 3450/1725 115 14.6/4.7 1.67 56Y B981 ★ Threaded Auto 1~.16 3450/1725 230 7.2/3.0 1.65 56Y B982 ★ Threaded Auto 1.5~.25 3450/1725 230 10.0/3.5 1.47 56Y B983 ★ Threaded Auto 2~.33 3450/1725 230 11.0/4.0 1.30 56Y B984 ★ Threaded Auto 230 10.0/3.5 1.10 56Y B985 ★ Threaded Auto

“C” Dim.

13.6 13.6 14.1 15.0 15.0

13.1 12.6 13.3 13.8 14.3 13.8

Notes

158 158 158

$

158

$

$ $ $

107

Notes: 107. Uprated – Low Service Factor 158. Open motor construction, overload protector mounted at 12 o'clock 351. eMod™ equipped motor eMod® motors on this page pass ASME A112.19.17 SVRS standard. eMod® will not prevent evisceration, hair, object or partial limb entrapment and is designed for suction lift applications. ▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov

www.aosmithmotors.com

13

Century® Above Ground Swimming Pool Pump Motors Jetted Tub/Spa/Above Ground Swimming Pool Pump Motors • Split Phase , Capacitor Start & PSC • Single-phase • Dripproof • Ball Bearing • Rigid Base & No Base • 3450 and 3450/1725 RPM • 1/2 thru 4 HP SPL Features: 12 & 3 O'clock Conduit Entries • 40°C Ambient • Class B Insulated • Rotation (CCW Pump End) • Through Bolt Mount • 48/56 Base Mounting • 3-1/2" Shaft Height • Four Thru Bolts on a 5.146 Bolt Circle Applications: Spa, above ground swimming pool and jetted tub pumps. Optional Flex-48 Accessories: Airswitch (#17800901), Single-speed Toggle Switch Assy. - On/Off (#18374501), Day/Night Controller (#18602401), Two-speed Toggle Switch Assy. - Lo/Off/Hi (#18313301)

BN24SS

Century Flex-48 W/Stainless Steel Shaft & Ball Bearings • "1081" • "1795" • "1563" • Rigid Base HP

RPM

1⁄2 3⁄4 1 1-1⁄2

3450 3450 3450 3450

2

3450

Volts

115 115 115 230/115 115 230/115

Hz

60 60 60 60 60 60

Full Load Amps

7.2 9.8 12.0 8.0/16.0 17.0 10.0/20.0

Service Factor

Frame

1.0 1.0 1.0 1.0 1.0 1.0

48Y 48Y 48Y 48Y 48Y 48Y

Stock Number

BN23SS BN24SS BN25SS BN35SS BV35SS BN40SS

Shaft

Threaded Threaded Threaded Threaded Threaded Threaded

Overload Protector

“C” Dim.

Notes

Auto Auto Auto Auto Auto Auto

11.08 11.08 11.58 12.08 12.08 13.33

Threaded Threaded Threaded Threaded Threaded

Auto Auto Auto Auto Auto

12.08 12.08 12.83 12.83 13.33

45 45 45 45

Threaded Threaded Threaded Threaded Threaded

Auto Auto Auto Auto Auto

12.83 12.83 13.33 14.33 14.33

45 68,145 68,145 68,90,145 68,90,145

“C” Dim.

Notes

45 45

Century Flex 48 LASAR Line (Low Amp Start and Run) • Two-speed • “1081” • “1563” • Rigid Base ®

3⁄4~.10 1~.12 1-1⁄2 ~.25 1-1⁄2 ~.18 2~.25

3450/1725 3450/1725 3450/1725 3450/1725 3450/1725

115 115 115 230 230

60 60 60 60 60

8.8/2.6 11.0/2.9 16.4/4.4 8.0/2.6 10.5/2.6

1.0 1.0 1.0 1.0 1.0

48Y 48Y 48Y 48Y 48Y

BN36 BN37 BN50 BN34 BN51

Century Flex 48 LASAR-XL • Extra Low Running Amps • Two-speed • Rigid Base 1~.12 1-1/2~.18 2~.25 3~.38 4.0~.42 SPL

3450/1725 3450/1725 3450/1725 3450/1725 3450/1725

115 115 230 230 208-230

60 60 60 60 60

10.3/3.1 13.8/3.8 8.5/2.8 12.0/3.5 12.0/3.5

1.0 1.0 1.0 1.0 1.0

48Y 48Y 48Y 48Y 48Y

BN38 BN60 ★ BN61 ★ BN62 ★ BN63 ★

ODB1102V1

Hoffinger Replacement (Doughboy/Lomart) • No Base HP

1

RPM

3450

Volts

Hz

Full Load Amps

Service Factor

Frame

Stock Number

Shaft

Overload Protector

115

60

10.0

1.0

48Y

BV90

Threaded

Auto

10.45

115

60

9.0

1.0

48Y

BV91

Threaded

Auto

10.22

285

Notes: 45. Capacitor start 68. PSC Motor 90 50˚C Ambient 145. Run capacitor mounted on motor shell 285. 3/8-16, Left hand threads, CWPE rotation

★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov

14

www.aosmithmotors.com

Two Compartment Pool Sweep Motors Smith-Seal Features: Auto Protector •Features Ball Bearings • Open Drip Proof • Single Speed • 40° C Ambient •• 60Auto HZ Protector • • • • •

Ball Bearings Open Drip Proof Single Speed 40° C Ambient 60 HZ

RPS1052

SPS1052

Special face mounted motors for use on Arneson “Pool Sweep”. HP

RPM

Volts

Max. Amps

Frame

Stock Number

Shaft

Notes

3/4

3450

115/230 115/230

12.4/6.2 12.4/6.2

48Y 48Y

SPS1052 RPS1052

Thrd Thrd

1,104 1,199

Notes: 1. Item to be discontinued when stock is depleted 104. Vertical Mount 199. Horizontal Rigid Base Pool Cleaner (Booster Pump) motors are not included in the California Energy Commission Appliance Regulations 2006 (Publication Number CEC 400-2006-002 REV1).

RPS/SPS

Sta-Rite Direct Replacement Spa Motors Features: • Open Construction • Rigid Base • Sealed Ball Bearing • Threaded Shaft • Thru-Bolt Mount • 50˚ C Ambient • 1.0 Service Factor • Energy Efficient • Auto Protector • 2-Speed (Capacitor Start Low Speed, PSC High Speed) • Rotation (CCW Pump End)

SDS1102

Replacement Motor for Dimension One, Hydroquip, GPM Industries, Hawkeye, Marquis and Master Spas

RPM

Volts

Amps

Frame

Stock Number

Insulation Class

Approx. “AG”

Dim. “BX”

1.0-.12

3450/1725

115

10.4/3.6

56Z

SDS1102 ★

B

10.30

8.85

1.5-.19

3450/1725

230

7.2/2.4

56Z

SDS1152 ★

F

10.79

9.34

2.0-.25

3450/1725

230

8.5/3.0

56Z

SDS1202 ★

F

11.42

9.98

2.5-.25

3450/1725

230

10.7/3.0

56Z

SDS1252 ★

F

10.67

9.23

3.0-.38

3450/1725

230

12.0/3.7

56Z

SDS1302 ★

F

10.92

9.48

HP

Notes

Note: When crossing to an original equipment A.O. Smith Motor, use the Quick Cross Reference table. Find the amps and model number of the OEM motor on the motor nameplate. Find the equivalent amps and model number on the Quick Cross Reference table below. The replacement is the stock number listed in the "Use" column. The horsepower and service factor may not be the same, but the motors are the same.

$ $ $ $ $

QUICK CROSS REFERENCE BY AMPS AND MOTOR MODEL NUMBER Name Plate Name Plate Use Amps Model No. Stock No. 10.4/3.6 K48L2A1 SDS1102 7.2/2.4 K48M2A4 SDS1152 8.5/3.0 K48N2A5 SDS1202 10.7/3.0 K48N2A4C2 SDS1252 12.0/3.7 K48P2A1 SDS1302 ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov

www.aosmithmotors.com

15

Century® Swimming Pool Pump Motors Squirrel Cage (Three Phase) • Dripproof • 3600/3000 RPM • 1/2 thru 3 HP Features: Ball bearings • 40°C Ambient • Class A or B Insulated • Cast Iron NEMA “C” Bracket • 303 Stainless Steel Shaft • Reversible (Three Phase) • 50/60 HZ

H281

60/50 Hz • Three Phase “1081” • Full Rate • High Service Factor Service Factor

Frame

Stock Number

Shaft

2.1-2.4/1.2 2.1-2.4/1.2 3.7-3.6/1.8 3.7-3.6/1.8 4.3-4.0/2.0 4.3-4.0/2.0

1.60 1.60 1.50 1.50 1.40 1.40

56C 56J 56C 56J 56C 56J

H281 H282 H450 H451 H513 H514

Keyed Threaded Keyed Threaded Keyed Threaded

208-230/460

5.9-5.6/2.8

1.30

56C

H616

208-230/460

5.9-5.6/2.8

1.30

56J

208-230/460

7.0-6.6/3.3

1.20

56C

HP

RPM

Volts

1⁄2

3450

3⁄4

3450

1

3450

208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460

1-1⁄2

3450

2

3450

Service Factor Amps@ 60 Hz

Overload Protector

Insul. Class

“C” Dim.

Notes

None None None None None None

A A A A A A

11.87 12.05 12.80 12.12 12.62 12.12

282 282 282 282 282 282

Keyed

None

A

13.24

282

H617

Threaded

None

A

12.62

282

H704

Keyed

None

A

13.62

282

Notes: 257. 60 Hz, only 282. 3450 RPM for 60 Hz and 2875 RPM for 50 Hz

Century® Pool Cleaner Replacement Pump Motors Permanent Split Capacitor • Switchless • Single Phase • Dripproof • No Base & Rigid Base • 3600 RPM Features: Ball bearings • 60 Hz • 40°C Ambient • Class B Insulated • CW Non-Reversible • 303 Stainless Steel Shaft • “1081” Features • Aluminum Adapter Bracket

B662 & B663

Applications: Replacement motor for Arneson “Pool Sweep,” Polaris “Vac-Sweep” and Letro "Jet Vac" brand pool cleaners. HP

RPM

Volts

3⁄4

3450

230/115 230/115 230/115 230/115 230/115 230/115

Service Factor Amps

6.4/12.8 6.4/12.8 6.0/12.0 6.0/12.0 6.0/12.0 6.5/13.0

Service Factor

Frame

Stock Number

1.50 1.50 1.50 1.50 1.50 1.50

56CZ 56CZ 56Y 56Y 56Y 56CZ

B625 BE625 B662 B663 B667 B668

Shaft

Threaded Threaded Threaded Threaded Threaded Threaded

Base

Mount

Overload Protector

“C” Dim.

Brand

Notes

None None Rigid None Rigid None

Horizontal Horizontal Horizontal Vertical Horizontal Horizontal

Auto Auto Auto Auto Auto Auto

14.03 14.03 11.74 10.89 12.97 13.87

Polaris Polaris Arneson Arneson Letro Letro

222 222,351 12 12 12,247 246

Notes: 12. 303 Stainless steel shaft 222. Does not have Aluminum Adapter Bracket 246. B668 fits pump #LA01N manufactured March 1997 to present 247. B667 fits pump #LA01 manufactured March 1997 and prior 351. eMod® equipped motor eMod® motors on this page pass ASME A112.19.17 SVRS standard. eMod® will not prevent evisceration, hair, object or partial limb entrapment and is designed for suction lift applications.

Pool Cleaner (Booster Pump) motors are not included in the California Energy Commission Appliance Regulations 2006 (Publication Number CEC 400-2006-002 REV1).

Pool cleaner (booster pump motors) are not included in the California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1).

16

www.aosmithmotors.com

Century® Purex Replacement Pump Motors Horizontal • Dripproof • No Base • 60 and 50 Hz • 3450 and 3450/2850 RPM • 5 thru 20 HP Features: Ball Bearings • 40°C Ambient • Service Factor 1.15 • Reversible • External Slinger Applications: Hydrotech (Purex) East Side “L” Series and “C” Series commercial pump. R236 HP

RPM

Volts

Full Load Amps

Hertz

Frame

Insul Class

Stock Number

Overload

“C” Dim.

Efficiency

Notes

Single Phase • Capacitor Start 5

3450

Three Phase 15.75 5 3450

230 230

60 60

25.6 25.6

184TY 184TY

B B

V214 V220

None None

15.7 15.8

77.0 77.0

153 152

60 60 60

14.0-13.5/6.75 14.0-13.5/6.75 21.6-19.4/9.7

182TY 182TY 184TY

F F F

R237 R236 R232

16.2 15.0 14.7

81.0 81.0 82.0

153 152 153

60 60

28.0-26.0/13.0 40.0-38.0/19.0

213TY 215TY

B F

R338 R339

None None None None None

19.4 21.4

87.5 88.6

153 153

7-1⁄2

3450

208-220/440 208-220/440 208-220/440

10 15

3450 3450

208-220/440 208-220/440

Notes: 1. Item to be discontinued when stock is depleted 152. Pump Series: L (threaded) 153. Pump Series: C (keyed)

Century® Square Flange Pool and Spa Pump Motors Squirrel Cage • Three Phase • Dripproof • No Base • 3600 RPM • 1/2 thru 3 HP Features: Ball bearings • 60 Hz • 50°C Ambient • Class B Insulated • 303 Stainless Steel Threaded Shafts

Service Factor Amps@ 60 Hz

HP

RPM

Volts

1⁄2 3⁄4 1 1-1⁄2 2 3

3450 3450 3450 3450 3450 3450

208-230/460 208-230/460 208-230/460 208-230/460 208-230/460 208-230/460

3.2-3.0/1.5 3.8-3.6/1.8 5.0-4.6/2.3 6.4-5.8/2.9 7.1-6.8/3.4 9.0-8.6/4.3

Service Factor

Frame

Stock Number

Shaft

1.90 1.65 1.65 1.47 1.30 1.15

56Y 56Y 56Y 56Y 56Y 56Y

H491 H492 H635 H636 H637 H755

Threaded Threaded Threaded Threaded Threaded Threaded

H491

Overload Protector

None None None None None None

“C” Dim.

Notes

12.2 12.8 13.2 13.4 13.9 13.9

Century® Pentair/Pac Fab Replacement Pump Motors Square Flange • Horizontal • Dripproof • No Base • 60 Hz B1000

Features: Ball Bearings • 40°C Ambient • Class B Insulation HP

Volts

Hertz

Full Load Amps

Service Factor

Frame

208-230 208-220/440

60 182TY

21.0-19.4 14.0-13.5/6.75

1.0 60/50

56Y C

208-230/460 208-230/460

60 60

11.0-10.4/5.2 13.4-13.4/6.7

1.15 1.0

56Y 56Y

RPM

Stock Number

Pac Fab Number

“C” Dim.

B1000 ▲ 81.

35-5705

14.9

H994 H995

35-5398 35-5704

13.9 14.9

Notes

Single Phase PSC "1081" 5

3450

5 3600/2900 Three Phase "1081" 3 5

3450 3450

▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov

www.aosmithmotors.com

17

Century® Waterway Replacement Pump Motors Dripproof • 60 HZ • Single Phase • Rigid Base • 6-1/2” Diameter • 3-1/2” Shaft Height Features: Ball Bearings • 50°C Ambient • 3/8-16 UNC-2A threads includes Slinger • Four thru bolts on a 5.812 Bolt Circle • Auto Protector • Permanent Split Capacitor

B232

HP-SPL

RPM

Volts

Full Load Amps

Frame

Stock Number

Insul. Class

“C” Dim.

Waterway Number

1.0 ~.18 2.0 ~.25 3.0 ~.30 4.0 ~.50 5.0 ~.63 4.0 5.0

3450/1725 3450/1725 3450/1725 3450/1725 3450/1725 3450 3450

230 230 230 230 230 230 230

6.4/2.6 8.0/3.0 10.0/3.5 12.0/4.4 16.4/4.8 12.0 16.4

56Y 56Y 56Y 56Y 56Y 56Y 56Y

B232 ★ B233 ★ B234 ★ B235 ★ B236 ★ B237 ▲ B238 ▲

F F F F F B B

10.87 11.87 12.12 13.37 13.37 12.62 13.37

3720621 3721021 3721421 3721621 3722021 3711821 3712021

Notes 108 108 108 108 108

Note: 108. Two speed motor

Century® Hayward North s tar Replacement Pump Motors NEMA C-Face • Dripproof • No Base • 60 Hz • Energy Efficient Features: Ball Bearing • Insulation Class B • Switchless • 50˚C Ambient • 60 Hz • E-Coated Main Frame for Superior Corrosion Resistance • 303 Stainless Steel Shaft • Low Noise • Cool Running for Longer Winding Life

SN1072

Volts

Full Load Amps

Service Factor

Frame

3450 3450 3450 3450 3450

208-230/115 208-230/115 208-230/115 208-230 208-230

6.0-5.5/11.0 8.5-7.8/15.6 11.0-10.2/20.4 13.0-11.8 20.6-19.0

1.85 1.85 1.60 1.35 1.60

56J 56J 56J 56J 56J

SN1072 SN1102 SN1152 SN1202 SN1302



3450 3450 3450 3450 3450

208-230/115 208-230/115 208-230/115 208-230 208-230

6.0-5.5/11.0 8.5-7.8/15.6 11.0-10.2/20.4 13.0-11.8 16.0-14.8

1.40 1.25 1.20 1.10 1.20

56J 56J 56J 56J 56J

USN1102 USN1152 USN1202 USN1252 USN1302



HP

RPM

Stock Number

Industry Number

“C” Dim.

SP1607Z1BNSC SP1610Z1BNSC SP1615Z1BNSC SP1620Z1BNSC SP1630Z1BNSC

13.10 13.35 13.85 14.60 16.10

$

Sp1607Z1MNSC SP1610Z1MNSC SP1615Z1MNSC SP1620Z1MNSC SP1625Z1MNSC

13.10 13.35 13.85 14.60 14.85

$

Notes

Full Rated 3/4 1 1-1/2 2 3

▲ ▲ ▲ ▲

$ $ $ $

Uprated 1 1-1/2 2 2-1/2 3

▲ ▲ ▲ ▲

$ $ $ $

▲ Meets California Energy Commission Appliance Regulations 2006 (Publication Number CEC-400-2006-002-REV1) ★ Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1) www.energy.ca.gov

18

www.aosmithmotors.com

Century® Close-Coupled Pump Motors Types JM, JP and TCZ • Three-Phase • Horizontal • Dripproof • Rigid Base • 3600 and 1800 RPM • 60 Hz • 1 thru 40 HP Features: Ball Bearings • 60 Hz • 40°C Ambient • Class B or F Insulated • External Slinger • Oversized, Locked Shaft End Bearing • Frame Suffix Letters TCZ Designate Century West Coast Pump Standard Motors Applications: Commercial/industrial pump duty. Designed to meet a wide variety of applications for fluid transfer E117

HP

RPM

Volts

Full Load Amps

Service Factor

Frame

1

1800

200-230/460 230/460 200-230/460 230/460 230/460 200-230/460 230/460 230/460 200-230/460 230/460 200-230/460 230/460 230/460 200-230/460 230/460 230/460 200-230/460 230/460 200-230/460 208-230/460 230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460

3.5-3.8/1.9 3.8/1.9 4.5-4.2/2.1 4.2/2.1 4.2/2.1 5.0-5.6/2.8 5.6/2.8 5.6/2.8 6.2-5.6/2.8 5.3/2.65 6.2-6.4/3.2 6.4/3.2 6.4/3.2 9.0-8.6/4.3 8.6/4.3 8.6/4.3 9.1-8.8/4.4 8.8/4.4 9.2-8.6/4.3 13.4-13.2/6.6 13.4/6.7 14.2-13.0/6.5 15.5-15.0/7.5 15.5-15.0/7.5 15.5-15.0/7.5 21.8-20.0/10.0 22.0-19.0/9.5 20.5-17.2/8.6 22.0-21.0/10.5 22.0-21.0/10.5 22.0-21.0/10.5 28.2- 27.0/13.5 28.2- 27.0/13.5 29.0-27.0/13.5 30.0-26.0/13.0 26.0/13.0 34.0-26.0/13.0 42.0-38.0/19.0 42.0-38.0/19.0 42.0-38.0/19.0 46.0-39.6/19.8 46.0-39.6/19.8 55.0-51.0/25.5 55.0-51.0/25.5 55.0-51.0/25.5 58.0-53.6/26.8 58.0-53.6/26.8 67.0-61.0/30.5 67.0-61.0/30.5 67.0-61.0/30.5 67.0-60.0/30.0 67.0-60.0/30.0

1.15 1.25 1.15 1.25 1.25 1.15 1.25 1.25 1.15 1.25 1.15 1.25 1.25 1.15 1.25 1.25 1.15 1.25 1.15 1.15 1.25 1.15 1.15 1.15 1.15 1.15 1.25 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.25 1.25 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15

143JM 143JP 143JM 143JP 143TCZ 145JM 145JP 145TCZ 145JM 145JP 145JM 145JP 145TCZ 145JM 145JP 145TCZ 182JM 182JP 182TCZ 182JM 182JP 182TCZ 184JM 184JP 184TCZ 184JM 184JP 184TCZ 213JM 213JP 213TCZ 213JM 213JP 213TCZ 15JM 215JP 215TCZ 215JM 215JP 215TCZ 254JM 254JP 254JM 254JP 254TCZ 256JM 256JP 256JM 256JP 256TCZ 284JM 284JP

1-1⁄2

3600

1800

2

3600 1800

3

3600

1800

5

3600

1800

7-1⁄2

3600

1800

10

3600

1800

15

3600

1800 20

3600

1800 25

3600

1800

Note: 1. Item to be discontinued when stock is depleted 6. 60/50 HZ 21. Terminal in bracket construction For mounting dimensions, see page 261

www.aosmithmotors.com

Stock Number

E117 E118 E119 E148 E149 E156 E157 E158 E159 E172 E174 E175 E176 E177 E178 E179 E294 E295 E276 E296 E297 E279 E282M E283M E284M E285M E286M E287M E368 E369 E370 E371M E372M E373M E374 E375 E376M E377 E378 E379 E482 E483 E485 E486 E487 E488 E489 E491 E492 E493 E566 E567

Insulation Class

B B B B B B B B B B B B B B B B B F B B F B F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F

"C" Dim.

14.40 17.85 14.87 17.85 17.85 14.87 17.85 17.85 15.40 17.85 15.40 17.85 17.85 15.40 17.85 17.85 16.88 19.94 18.02 17.12 20.18 19.52 14.97 19.11 18.02 16.97 20.78 20.78 17.43 21.31 20.49 18.43 22.31 21.49 17.43 21.31 20.47 19.93 23.81 22.59 20.88 20.88 23.60 26.48 26.48 23.60 26.48 23.60 26.48 26.48 24.86 27.74

Efficiency

Notes

84.0 81.5 86.5 86.5 86.5 84.0 81.5 81.5 82.5 82.5 81.5 81.5 81.5 84.0 84.0 84.0 85.5 85.5 84.0 86.5 86.5 80.0 82.5 85.5 85.5 82.0 85.5 87.5 87.5 87.5 87.5 86.5 86.5 88.5 88.5 88.5 88.5 88.5 88.5 88.5 88.5 88.5 90.2 90.2 90.2 87.5 87.5 90.2 90.2 90.2 91.0 91.0

6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21 6,21

1 1

Continued on next page

19

Century® Close-Coupled Pump Motors

Continued from previous page

Types JM, JP and TCZ • Three-Phase • Horizontal • Dripproof • Rigid Base • 3600 and 1800 RPM • 60 Hz • 1 thru 40 HP Features: Ball bearings • 60 Hz • 40°C Ambient • Class B or F Insulated • External Slinger • Oversized, Locked Shaft End Bearing • Frame Suffix Letters TCZ Designate Century West Coast Pump Standard Motors • 1.15 Service Factor Applications: Commercial/industrial pump duty. Designed to meet a wider variety of applications for fluid transfer.

HP

RPM

30

3450 1725

40

3450

Volts

200-230/460 200-230/460 200-230/460 200-230/460

E569

Full Load Amps

Frame

Stock Number

Insulation Class

"C" Dim.

Efficiency

Notes

81.0-70.0/35.0 81.0-72.0/36.0 81.0-72.0/36.0 104.0-90.0/45.0

284JM 286JM 286JP 286JP

E569 E572 E573 E576

F F F F

24.86 26.36 29.24 29.24

89.5 91.7 91.7 91.0

1 1 1 1

Century® Close-Coupled Pump Motors Three Phase • Type JM • Dripproof • NEMA “C” Face • No Base • 50/60 Hz Features: Double Sealed Ball Bearings, 60/50 Hz Markings on Nameplate, 40°C Ambient, Class B Insulated, External Shaft Slinger, Oversized, Locked Shaft End Bearing, Terminal In Bracket Construction.

E159RF

Applications: Commercial pump duty. Designed to meet a wide variety of applications for fluid transfer. HP

RPM

1 1.5 2

1800 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800

3 5 7.5 10

Volts

200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 208-230/460 200-230/460 200-230/460 200-230/460 200-230/460 200-230/460

Full Load Amps

Service Factor

3.5-3/8/1.9 5.0-5.6/2.8 6.2-5.6/2.8 6.2-6.4/3.2 9.0-8.6/4.3 9.1-8.8/4.4 13.4-13.2/6.6 15.5-15.0/7.5 21.8-20.0/10.0 22.0-21.0/10.5 29.0-27.0/13.5 34.0-26.0/13.0

1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.25 1.25 1.15 1.15 1.25

Frame

Stock Number

"C" Dim.

143JM 145JM 145JM 145JM 145JM 182JM 182JM 184JM 184JM 213JM 213JM 215JM

E117RF E156RF E159RF E174RF E177RF E294RF E296RF E282RF E285RF E368RF E371RF E374RF

14.4 14.9 15.4 15.4 15.4 16.9 17.1 15.0 17.0 17.5 18.4 17.5

Efficiency

Notes

84.0 84.0 84.0 81.5 84.0 85.5 86.5 85.5 82.0 87.5 88.5 88.5

220 220

Notes: 1. Item to be discontinued when stock is depleted 220. Dripcover kit available (Part # 103017-02). For mounting dimensions, see page 261

20

www.aosmithmotors.com

Century® Industrial Close-Coupled Pump Motors Types JM, JP and TCZ • Three-Phase • Horizontal • TEFC • Rigid Base • 3600 and 1800 RPM • 1 thru 25 HP Features: Ball Bearings • 60 Hz • 40°C Ambient • Class B or F Insulated • Service Factor 1.15 • External Slinger • Oversized, Locked Shaft End Bearing • Frame Suffix Letters JM and JP Designate NEMA Standard Motors. Frame Suffix TCZ Designates Century West Coast Pump Standard Motors. N346

Applications: Designed for the specific requirements of centrifugal pumps.

HP

RPM

Volts

Full Load Amps

Frame

1

1800 3600 1800 3600 1800 3600

200-230/460 200-230/460 200-230/460 200-230/460 200-230/460 230/460 208-230/460 200-230/460 230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 230/460 200-230/460 200-230/460

3.3-3.4/1.7 4.5-4.2/2.1 4.5-4.4/2.2 6.0-5.3/2.65 5.9-5.6/2.8 7.8/3.9 8.5-8.2/4.1 8.2-7.2/3.6 10.4/5.2 10.4/5.2 8.4/4.2 9.0-8.0/4.0 9.0-8.0/4.0 13.0/6.5 13.0/6.5 12.0/6.0 13.9-11.8/5.9 13.9-11.8/5.9 13.6/6.8 13.6/6.8 13.0/6.5 15.0-12.8/6.4 15.0-12.8/6.4 19.0/9.5 19.0/9.5 21.2-18.8/9.4 21.2-18.8/9.4 20.0/10.0 20.0/10.0 19.6/9.8 21.0-18.9/9.45 21.0-18.9/9.45

143JM 143JM 145JM 145JM 145JM 182JM 145JM 182JM 182JM 182JP 182TCZ 182JP 182JM 184JM 184JP 184TCZ 184JM 184JP 184JM 184JP 184TCZ 184JP 184JM 213JM 213JP 213JM 213JP 213JP 213JM 213TCZ 213JP 213JM

1-1⁄2 2 3

1800

5

3600

1800

7-1⁄2

3600

1800

Stock Number

N149 N148 N161 N153 N163 N223 N157 TCP71004 N232 N252 N251 TCP72029 TCP71029 N245 N240 N209 TCP71005 TCP72005 N246 N219 N211 TCP72030 TCP71030 N342 N335 TCP71006 TCP72006 N329 N344 N311 TCP72031 TCP71031

Insulation Class

B B B B B F B F F F F F F F F F F F F F F F F F F F F F F F F F

Cast Iron

√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √

"C" Dim.

16.0 16.0 16.0 16.0 16.0 18.2 17.5 17.2 18.2 21.3 21.1 20.9 17.2 18.2 21.3 21.1 17.2 20.9 18.2 21.3 21.1 20.9 17.2 21.4 25.3 21.1 24.9 25.5 21.4 22.6 24.9 21.1

Efficiency

Notes

82.5

1,291 291

85.5 82.5 82.5 85.5 87.5 87.5 83.5 83.5 85.5 87.5 87.5 86.5 86.5 86.5 87.5 87.5 85.5 85.5 88.5 88.5 86.5 86.5 86.5 89.5 89.5

1,291 1 291

1,291 1 291

1,291 1 291

1,291 1

1 1,291 333

Notes: 1. Item to be discontinued when stock is depleted 291. 208 Volt @ 1.0 Service Factor 333. Aluminum shell For mounting dimensions, see page 261

www.aosmithmotors.com

21

Continued from previous page

Century® Industrial Close-Coupled Pump Motors Types JM, JP and TCZ • Three-Phase • Horizontal • TEFC • Rigid Base • 3600 and 1800 RPM • 1 thru 25 HP Features: Ball Bearings • 60 Hz • 40°C Ambient • Class B or F Insulated • Service Factor 1.15 • External Slinger • Oversized, Locked Shaft End Bearing • Frame Suffix Letters JM and JP Designate NEMA Standard Motors. Frame Suffix TCZ Designates Century West Coast Pump Standard Motors.

N346

Applications: Designed for the specific requirements of centrifugal pumps.

HP

RPM

Volts

Full Load Amps

Frame

10

3600

230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460 230/460 230/460 200-230/460 200-230/460

26.0/13.0 26.0/13.0 25.0/12.5 29.4-24.0/12.0 29.4-24.0/12.0 26.0/13.0 26.0/13.0 28.3-25.2/12.6 28.3-25.2/12.6 36.0/18.0 36.0/18.0 40.0-35.0/17.6 40.0-35.0/17.6 36.0/18.0 36.0/18.0 40.9-36.6/18.3 40.9-36.6/18.3 46.0/23.0 46.0/23.0 53.2-47.0/23.5 53.2-47.0/23.5 48.0/24.0 48.0/24.0 56.7-49.2/24.6 56.7-49.2/24.6 60.0/30.0 60.0/30.0 66.1-59.0/29.5 66.1-59.0/29.5 62.0/30.0 63.0/31.5 67.9-62.0/31.0 67.9-62.0/31.0

215JM 215JP 215TCZ 215JM 215JP 215JM 215JP 215JP 215JM 254JM 254JP 254JM 254JP 254JM 254JP 254JM 254JP 256JM 256JP 256JM 256JP 256JM 256JP 256JP 256JM 284JM 284JP 284JM 284JP 284JM 284JP 284JM 284JP

1800

15

3600

1800

20

3600

1800

25

3600

1800

Stock Number

N343 N346 N313 TCP71007 TCP72007 N345 N347 TCP72032 TCP71032 N417 N432 TCP71008 TCP72008 N424 N419 TCP71033 TCP72033 N425 N433 TCP71009 TCP72009 N426 N435 TCP72034 TCP71034 N516 N523 TCP71010 TCP72010 N535 N525 TCP71035 TCP72035

Insulation Class

Cast Iron

"C" Dim.

Efficiency

Notes

F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F

√ √

21.0 24.8 24.1 21.1 24.9 21.6 25.5 24.9 21.1 26.8 29.6 26.9 29.8 26.8 29.6 26.9 29.8 26.8 29.6 26.9 29.8 26.1 29.6 29.8 26.9 28.4 28.0 27.8 30.7 25.9 28.0 27.8 30.7

84.0 84.0 85.5 89.5 89.5 88.5 88.5 89.5 89.5 86.5 86.5 90.2 90.2 89.5 89.5 91.0 91.0 87.5 87.5 90.2 90.2 91.7 91.0 91.0 91.0 87.5 87.5 91.0 91.0 91.7 91.7 92.4 92.4

1,291 1 333

√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √

1,291 1

1 1

1 1

1 1

1 1

1 1

1 1

Notes: 1. Item to be discontinued when stock is depleted 291. 208 Volt @ 1.0 Service Factor 333. Aluminum shell For mounting dimensions, see page 261

22

www.aosmithmotors.com

Century® Close-Coupled Pump Motors Types JM, JP and WCP • Single-Phase • Horizontal • Dripproof • Rigid Base • 3600 and 1800 RPM • 1 thru 10 HP Features: Double Sealed Ball Bearings • 60 Hz • 40°C Ambient • Class B Insulated • Service Factor 1.15 • Reversible • External Slinger • Oversized, Locked Shaft End Bearing. • Frame suffix letters JM and JP Designate NEMA Standard Motors. Frame suffix TCZ Designates Century West Coast Pump Standard Motors.

P137

Applications: Designed for the specific requirements of centrifugal pumps.

HP

RPM

Volts

Full Load Amps

Frame

1

1800

1-1⁄2

3600

115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 115/230 230 230 200 115/230 115/230 230 230 200 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230

15.0/7.5 15.0/7.5 16.0/8.0 16.0/8.0 15.0/7.5 18.0/9.0 19.2/9.6 19.2/9.6 20.4/10.2 25.0/12.5 25.0/12.5 13.4 13.4 15.6 32.0/16.0 34.0/17.0 20.0 22.0 24.0 26.0 26.0 26.0 25.0 25.0 25.0 39.0 39.0 39.0 32.0 32.0 32.0 42.5 42.5 42.5

143JM 143JP 143JM 143JP 145JM 145JP 145JM 145JP 182JM 182JM 182JP 182JM 182JP 182JM 182JM 184JM 184JM 184JP 184JM 184JM 184JP 184TCZ 213JM 213JP 213TCZ 213JM 213JP 213TCZ 215JM 215JP 215TCZ 215JM 215JP 215TCZ

1800 2

3600 1800

3

3600

5

1800 3600

1800

7-1⁄2

3600

1800

10

3600

Stock Number

P121 P126 P122 P127 P123 P128 P124 P129 P137 P228 P232 P130 P131 P132 P229 P230 P140 P135 P133 P231 P235 P212 P317 P324 P312 P318 P325 P311 P319 P326 P313 P320 P327 P321

"C" Dim.

15.54 18.60 15.54 18.60 16.29 18.60 15.54 18.60 16.29 16.04 18.93 16.29 19.35 16.29 16.04 17.04 17.12 20.10 17.04 17.04 19.93 20.11 17.63 20.69 20.69 17.63 20.69 20.69 19.13 22.19 22.19 19.13 22.19 22.19

Efficiency

Notes

21 21 21 21 21 21 21 21 21 72.5 72.5 21 21 21 72.2 77.0 83.9 21 21 78.5 78.5 77.0 81.0 81.0 81.0 77.0 77.0 86.0 86.0 86.0 86.0 83.8 83.8 83.8

Notes: 21. Terminal in bracket construction For mounting dimensions, see page 261

www.aosmithmotors.com

23

Commercial Pump Motor Cross Reference SINGLE-PHASE HP 3 3 3 5 5 5 5 7.5 7.5 10

RPM 3600 3600 1800 3600 3600 3600 1800 3600 1800 3600

230 (115) VOLT ODP

FRAME 182JM 182JM 184JM 184JM 184TY 184TY 184JM 213JM 215JM 215JM

AOS P229 P130 P230 P231 V214 V220 P317 P318 P319 P320

MARATHON Z406

BALDOR JML1406T

Z407 Z408

JML1408T JML1409T

EMERSON

GE

STA-RITE BERKLEY

ITT-MARLOW

AURORA

PENTAIR/PUREX

DMH/DDH DMJ/DHJ

3B28EC-C2-1 CH50/CM50 LH50

Z409 Z410 Z411 Z412

JML1508T JML1509T JML1510T JML1511T

CSPHK

3B32EC-C2-1 341A-3X4X9B-7.5-1

CSPHL

THREE-PHASE 230/460 VOLT ODP HP 3 3 5 5 5 5 7.5 7.5 7.5 10 10 10 15 15 15 20 20 20 25 25

RPM 3600 1800 3600 3600 3600 1800 3600 3600 1800 3600 3600 1800 3600 3600 1800 3600 3600 1800 3600 1800

FRAME 145JM 182JM 182JM 182TY 182TY 184JM 184JM 184TY 213JM 213JM 213TY 215JM 215JM 215TY 254JM 254JM 254TY 256JM 256JM 284JM

AOS E177 E294 E296 R237 R236 E282 E285 R232 E368 E371 R338 E374 E377 R339 E482 E485 R346 E488 E491 E566

MARATHON M311 M313 M315

BALDOR JMM3158T JMM3211T JMM3212T

EMERSON DJ3S1AM DJ3S2AM DJ5S1AM

GE N846 N704 N705

STA-RITE BERKLEY DMH3/DHH3

ITT-MARLOW

DMJ3/DHJ3

3B28EC-C2-3

AURORA

PENTAIR/PUREX

CHK50/CMK50 LHK50 M317 M319

JMM3218T JMM3219T

DJ5S2AM DJ7S1AM

N706 N707

M321 M323

JMM3311T JMM3312T

DJ7S2AM DJ10S1AM

N708 N709

M325 M327

JMM3313T JMM3314T

DJ10S2AM DJ15S1AM

N710 N711

CSPHM3

M329 M330

JMM2514T

DJ15S2AM DJ20S1AM

N712 N713

CSPHN3

DJ20S2AM DJ25S1AM DJ25S2AM

N714 N715 N716

EMERSON UJ3S1AM UJ3S2AM UJ5S1AM UJ5S2AM UJ7S1AM UJ7S2AM UJ10S1AM UJ10S2AM UJ15S1AM UJ15S2AM UJ20S1AM UJ20S2AM UJ25S1AM UJ25S2AM

GE N735 N737 N738 N739 N740 N741 N742 N743 N744 N745 N746 N747 N748 N749

CSPHK3

3B32EC-C2-3 CMK75/CHK75

M331 M332 M333

JMM2515T JMM2516T

341A-3X4X9B-7.5-3 CSPHL3

L SERIES L SERIES L SERIES L SERIES L SERIES L SERIES L SERIES L SERIES L SERIES

CMK100/CHK100 341A-3X4X9B-10-3 CMK150/CHK150 341A-3X4X9B-15-3 CHK200 341A-4X5X11-20-3 341A-4X5X11-25-3

THREE-PHASE 208-230/460 VOLT TEFC HP 3 3 5 5 7.5 7.5 10 10 15 15 20 20 25 25

24

RPM 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800 3600 1800

FRAME 182JM 182JM 184JM 184JM 213JM 213JM 215JM 215JM 254JM 254JM 256JM 256JM 284JM 284JM

AOS N223 N232 N245 N246 N342 N344 N343 N345 N417 N424 N425 N426 N516 N535

MARATHON M405 M406 M407 M408 M409 M410 M411 M412 M413 M420 M414 M421

BALDOR JMM3610T JMM3611T JMM3613T JMM3615T JMM3709T JMM3710T JMM3711T JMM3714T JMM2394T JMM2333T JMM4106T JMM2334T JMM4107T JMM4103T

STA-RITE BERKLEY

ITT-MARLOW

AURORA

PENTAIR/PUREX

M08311 M10490 S34562

www.aosmithmotors.com

ENERGY SAVINGS ESTIMATOR Your pool professional can tell you which High Efficiency Motor on the chart below replaces your current swim pool pump motor. The High Efficiency Motor will save you money every month on your electric bill. Use the chart below to find your yearly savings. Divide the cost of a new High Efficiency Motor by yearly savings and the result is how long it will take to get your money back. At the end of the payback period, you will have saved the cost of the motor in energy bills and the ongoing savings will go directly into your pocket.

Approximate yearly energy savings based on using an Energy Efficient motor in place of a standard pool and spa motor with industry-average efficiency: “C” Flange: Hayward – Jacuzzi and Others Hours Per Day Operation

E n e rgy Efficient Models HP

Square Flange: Sta-Rite – Pentair and Others Hours Per Day Operation

Century®

8

10

12

$27.95

$34.94

$41.93

1/2

1.60

$27.95

$34.94

$41.93

3/4

1.00

$34.08

$42.72

$51.24

3/4

1.50

$34.08

$42.72

$51.24

1

1.00

$32.04

$40.08

$48.00

1

1.40

$32.04

$40.08

$48.00

1-1/2

1.00

$49.20

$61.44

$73.80

1-1/2

1.30

Energy Efficient Models HP

SF B656, B657

B631, B634, B638

AOSmith

8

10

12

AOSmith

CT1052

$57.24

$71.64

$85.92

1/2

1.90

B845

QC1052

$57.24

$71.64

$85.92

3/4

1.25

B862SE

UQC1072

CT1072

$36.00

$45.12

$54.12

3/4

1.67

B661

QC1072

$36.00

$45.12

$54.12

1

1.25

B863SE

UQC1102

$55.20

$69.00

$82.80

1

1.65

B841

QC1102

$55.20

$69.00

$82.80

1-1/2

1.10

B864SE

UQC1152

$65.76

$82.32

$98.76

1-1/2

1.47

B842

SQ1152

$65.76

$82.32

$98.76

2

1.10

B865SE

USQ1202

$71.16

$89.04

$106.80

2

1.30

B843

SQ1202

$71.16

$89.04

$106.80

2-1/2

1.04

B866SE

USQ1252

$16.08

$20.02

$24.12

3

1.15

B844

SQ1302

CT1102 UCT1152

B750, B795, B796

Century®

UCT1072

UCT1102 B653, B654, B723

SF

ST1152

$61.44

$76.92

$92.28

2

1.20

B772, B808, B809

ST1202

$16.08

$20.04

$25.20

3

1.15

B774, B817, B818

ST1302

Bulletin #1081/1082 04-07