audio - video - digital - light - composite - Reference Laboratory

1 downloads 182 Views 6MB Size Report
RLCM-SF series - superflex multiwires. 54. RLCM-ZH series - multiwires ...... along the cable and the 100 ohm impedance
audio - video - digital - light - composite

CATALOGUE 2010 - 6TH EDITION

D MA E I N

ITALY

C A BL E S

Looking ahead in Pro Audio

Reference Laboratory “Cable's Philosophy” a “sub woofer, mid and high” format to ensure optimum signal reproduction; at least a pair of cables of the same length, connected to masters A and B, with the same settings (EQ-flat, gain 0dB) 2. Alternate one cable with the other, doing your utmost to memorize the two responses, listening in a pair of headphones and directly to the system’s output. From 1992 to the present day, Reference Laboratory has managed to design its cables bearing in mind: - different fields of application (Studio and Live work) - different music genres and styles, to give the proper importance to the various requirements in terms of frequency response, such as for example in ROCK music. - requisites regarding accurate reproduction of both electric and electro-acoustic instruments - the necessary characteristics for using both Dynamic and Condenser microphones. - requirements of minimum power loss along the line and signal transparency, above all for "LINE ARRAY" sound systems whether they are for live use or subject to norms regarding permanent installations - requisites of power cables dedicated to use with discharge lighting fixtures - new technologies - composite cables carrying control, audio and video signals are increasingly useful - logistic limits - to face very demanding situations or great environmental differences: we are always ready to listen to end users to ensure greater satisfaction (including that of the public or audience), designing and preparing custom turnkey solutions able to meet every need. On-going development - our technology depends on interaction with users to develop new ideas that bear in mind the improvement of the state of the art of the audio, video, lighting and power supply chains, NEVER penalizing the technology used upstream.

ABBIAMO IL PIACERE DI INTRODURRE IL NOSTRO FORMAT: STOP E ASCOLTA IL CAVO REFERERENCE 1. La chiave di tutto sta nel far comprendere QUANTO il segnale possa variare, nel medesimo circuito (bilanciato, sbilanciato e di potenza), sostituendo il CAVO. 2. La nostra ricerca nella progettazione dei cavi è sempre stata guidata da questa esigenza. 3. Abbiamo ANCHE valutato fosse necessario individuare un metodo, il+semplice, + trasparente ,+ realizzabile per consentire a TUTTI di "Valutare" un CAVO. 4. Con un po’ di CORAGGIO presentammo al Meet 05' in Milano il format "VIENI AD ASCOLTARE IL CAVO REFERENCE. Musicisti, tecnici, media ed addetti al lavoro: TUTTI mostrarono sorpresa e curiosità di fronte alla nostra iniziativa e si resero subito disponibili alla prova di ascolto. La reazione fu immediatamente POSITIVA grazie all’immediatezza del test che permetteva di toccare con mano (e orecchio!) la differenza tra set-up di cavi diversi. Finalmente un metodo, nuovo e utilissimo per affinare il proprio set-up strumentale. Un deciso taglio col passato, quando il cavo altro non era che un accessorio, necessariamente a basso costo e inutile si fini del sound. Il cavo si deve scegliere allo stesso modo e con la stessa cura con cui si sceglie uno strumento, delle corde, degli effetti o un amplificatore! 5. Grazie a tale successo portammo il “METODO REFERENCE Lab” in ogni fiera nazionale ed internazionale, istituimmo Clinics, e stabilimmo che il cavo Reference Laboratory fosse disponibile solo attraverso rivenditori "selezionati": denominati Ambassador. Un AMBASSADOR è un distributore (dealer o rivenditore locale) convinto e impegnato a svolgere le dimostrazioni secondo il METODO REFERENCE Lab. Abbiamo sottolineato il Metodo in prima pagina anche nel nostro catalogo. Per chi è interessato e vuol saperne di più, in occasione di fiere e clinics, saremo in grado di fornire loro test audio e set-ups su cui fare le proprie prove. 6. Tutto questo per contribuire a quella che amiamo definire la “cultura del cavo” e fornire gli strumenti per distinguere, tra l’altro, tra il concetto di prezzo e quello di qualità sonora: non sempre il prezzo elevato corrisponde ad una prestazione sonora equivalente!! 7. La regola a nostro avviso è quella di ascoltare il CAVO con le proprie orecchie ,attraverso il proprio strumento ed il proprio stile, quindi come meglio indicato nel METODO Reference Laboratory: Il METODO REFERENCE Lab in pochi passi “Il MEDOTO REFERENCE Lab è una rigorosa comparazione audio, possibilmente cieca” Valutazione di un cavo per strumento Ascoltare il proprio strumento (chitarra o basso) in due steps: 1. attraverso un mixer con ascolto in cuffia. 2. poi attraverso il proprio amplificatore ( ho un amplificatore del quale già si conosce il “suono”) Tenendo a mente quell'accordo e quel sound, ripetere la prova (medesima esecuzione) sostituendo il CAVO . Ripetere la prova finché non si è certi di aver compreso le differenze tra i due cavi . Una volta notata la differenza passate ad ascoltare il cavo tramite l’amplificatore È FONDAMENTALE tenere a mente il suono di un cavo, dimenticandone il modello e la marca, concentrandosi solo sull'estensione e la colorazione della risposta acustica... Solo così passando ad un altro CAVO verrà naturale SENTIRNE le differenze, e quindi valutare e scegliere il cavo + adatto al proprio stile. PERCHE' RICHIEDIAMO di svolgere la comparazione sia attraverso l'ascolto in Cuffia che con un Amplificatore? Perché i due metodi di riproduzione rivelano aspetti diversi del segnale e permettono di valutare l’impatto di un cavo sia sulla linea che filtrato da un altoparlante. Valutazione di un cavo per microfonico 1. Set-up necessario: - un mixer ed un sistema audio in configurazione mono ; il sistema di diffusori deve essere possibilmente in formato “sub, woofer, medi, alti” per fornire una rappresentazione ottimale del segnale; - almeno un paio di cavi di pari lunghezza, collagati ai master A e B, con le stesse regolazioni (EQ-flat, gain 0dB) 2. Utilizzare alternativamente un cavo e poi l’altro, sforzandosi di memorizzare le due risposte, andando in ascolto sia in cuffia che in diretta dal sistema . Dal 1992 ad oggi la Reference Laboratory è riuscita a progettare i suoi cavi tenendo conto di: - campi di applicazioni diversi (Studio e Live) - diversi stili musicali, per dare giusto rilievo alle diverse esigenze in termini di risposta in frequenza, come ad esempio nella musica ROCK. - requisiti di fedeltà di riproduzione sia di strumenti elettrici che elettro-acustici - caratteristiche necessarie per alimentare sia un microfono Dinamico che uno a Condensatore - esigenze di minima perdita di potenza sulla linea e trasparenza del segnale, soprattutto per i sistemi audio "LINE ARRAY", siano essi in Live che soggetti alle normative per le Installazioni Fisse - requisiti dei cavi di potenza dedicati alle luci a scarica - nuove tecnologie - Risultano sempre più utili cavi compositi, con segnali di controllo, audio, e video - vincoli logistici - per affrontare situazioni molto impegnative o grandi diversità ambientali: siamo sempre pronti all’ascolto per aumentare la soddisfazione dell’operatore e… del pubblico, sviluppando soluzioni chiavi in mano su misura. - lo sviluppo continuo - la nostra tecnologia non può fare a meno del confronto con l'utilizzatore per sviluppare sempre nuove soluzioni con in mente il miglioramento dello stato dell’arte delle catene audio, video, luci e di potenza, senza MAI penalizzare le tecnologie a monte.

www.referencelaboratory.com

p.2

Inside Reference Osimo September '08 Bogotà

Reference Labs considers travelling as the best occasion to meet "End Users"&"Dealers". This is the main step to decide what to do on planning a suitable production and making customers appreciating it. Then it is very much important because it makes you able to understand how much markets know about audio, video and light audio CABLES technology. All respectful relationships make people growing by sharing every opinion. In the same way the human aspect of relationships is very much determinative to satisfy each other requirements and then to solve problems and assume hypothesis as a real team. Unfortunately the actual way of communicating is running the risk to reduce the human contact to simply essential ordered actions like "Please ,fill in the form" for asking information and "push the bottom" to answer them. When this human kind of communication is applied on a cable(a cable which someone still call "wire")it means we have the possibility of breaking a banner just starting with a friendly talk to arrange something interesting just giving suggestions and talking about technical features, power, loudspeakers, application conditions like outdoor or indoor installations... Every year, during every shows, it always happen that customers which could represent NEW contacts visit us to ask for catalogs, price lists, samples and they always check Singapore cables quality just by their flexibility. Reference Lab does not have any to do with this way of working...because we are looking for a dialogue with costumers to understand and satisfy any requirements. Our aim is to get some important information from showvisitors like the golden one which is: "What kind of utilisation and applications are our cables destinated to in your company projects?" As a matter of fact we consider the word "application" as the key-code which makes it possible to share a growing process which starts with the consumers requirements and finishes at the company production projects. Regarding to this Reference Lab is supposed to get a deeper knowledge of cable technology by organizing seminaries which take place both at shows (Moscow,) organized by Mr. Wladimir Sohno of Bayland Music, during Moscow trainings (Sharjan,) organized by Mr. Vishnu Manghnani in Studio Ayoub Essa with his engineers: in Caracas (Venezuela); in Bogotà (Columbia); In Belo Horizonte (Brasil); in Manila (Philippines); in Mumbai (India); in Beijng (China); in Kuala Lumpur (Malaysia) and as sponsor of Clinics at the Umbria Jazz festival with the collaboration of Mr. Carlo Pagnotta, Giovanni Tommaso, Larry Monroe and Angelo Tordini, whose purpose is making users understand the importance of such an accessory as the cable because it can produce very excellent and best sound results at the end of an audio www.referencelaboratory.com

p.3

Inside Reference Berklee UJ 07

system team performance. We absolutely don't want to strictly criticize this attitude, but we would really like to suggest people to learn analysing cable features as they do with many other audio products. The reason is that cables are the more important link between the complete audio equipment and its results from a quality sound point of view. Cables make the difference in sound! If you think to everyone guitarist or vocalist during their studio recording job, you'll surely associate your idea to the quality results reached by a good sound crew who works with the support of excellent instrumental equipment like consolle, recorder, processors, microphones. If in that session you'd replace just the guitar and the microphone (vocal) cables and you'd repeat the performance, you'll be listening to the sound of this new track with many big quality differences in comparison with the past one. We noticed that this improvement of the cable concept is really welcome all over in the World and someone has already expressed his satisfied and positive opinion about what excellent results come from a new way of dedicating more time and attention to the choice of a more suitable and low price cable. Caracas

I would SINCERELY thank to people and companies which have been trusting Reference Lab by investing on our brand, products and human resources and also all of them who have been testing our products to finally choose them for the qualified sound results they produce. Reference would continue to invest on a developing research which is the base of its way of working. Reference Organizer for SOUND CREW is just A LITTLE OBJECT dedicated to people who both spiritually and practically special great. Angelo Tordini

Berklee UJ o7

Towards a culture of the cables In Italy, nine years after its first appearance REFERENCE laboratory plays now a significant role on the musical scene thanks to the originality and incisiveness the become natural characteristics of its initiatives. PRODUCTS conceived and designed by a team of audio engineers. All their experience to find the brightest answers to the needs of professionals and amateurs, for any application and environment: from studio to home recording, broadcasting facilities and TV; from live events to fixed installations and any other pro-audio task. ACCESSORIES designed with the needs of musicians and sound engineers in mind. A wide range of tools where even the smallest detail – i.e. the Strapper, the Cable Drum patented is customized to professionals needs, in studio and on the road. RANGE each model is designed to best meet both mechanical and electrical specifications for a particular task. The result is a wide range of professional cables for audio (microphone, instrument, speaker, AES-EBU, multicore, AC-line), video and light applications. www.referencelaboratory.com

p.4

Inside Reference FEATURES AND SPECIFICATIONS the manufacturing process of each product satisfies the demanding ISO 9002 Quality Standard. Every item is tested during production and re-checked before final delivery. NPI and LSZH properties of materials are tested and certified by IMQ.

QUALITY SYSTEM CERTIFICATE

standard

ISO 9002/EN2902

OXIGEN FREE Reference cables use only pure (99.97%) oxygen-free copper conductors, for premium signal transmission quality and reliability over time. INNOVATIVE MATERIAL polyurethane, for the first time to improve the cable’s managing in hard condition (-40/+80°C) then more flexibility, high abrasion hardness, high resistance to mineral oils, high mechanical reliability. LEADING THE END-USER TO A “CULTURE OF THE CABLE” knowledge is the best tool to make the right choices. Reference Laboratory introduced the Reference Info Book as a guide to identify the characteristics important for specific jobs, together with the general information needed about cables (terminology, & ). A valuable help in a field where the right choice can really make the difference.

b La

LA R

ce en er ef R

RLA “THINKING ABOUT THE APPLICATIONS” it’s the main significant key for Reference’s Research and Marketing Development; in fact it was introduced “RLA” (Reference Lab. Application) into this catalogue in order to certificate “ for a specific job” (application) the “right cable” thought an international mentality’s approce on pro audio and M.I. markets.

n io at lic pp A

Important cables parameters Resistance (R) Measured in Ohms/Unit lenght (mt.) the resistance of the conductors is an important primary factors to the determination of the signal carring-capacity of the transmission line. The resistance value is also the ratio of the electrical resistivity of the conductor material to its physical cross-sectional area. For microphone cable conductor resistance range: 70-150 Ohm/Km.

Capacitance (C) Measured in picofarad unit length (mt.) and refers on audio cables, between conductor or conductors and shield. For transmission applications is desiderable use cables with lowdielectric-constant materials like proplylene or

cellular polyethylene or polypropylene. For instrument cable the range is 70-130 pF/mt. (between conductors).The capacitance vary also varies with the distance between conductors.

Attenuation (Alfa) Mesured indB/Unit lenght (mt.). Attenuation determines the transmission level loss of a line. The main factors witch cause attenuation are resistive loss in the conductor (mainly due to conductor skin effect at high frequency) and loss in the dielectric.

Inductance The inductance of a circuit or an individual conductors may play a part in performance of a loudspeaker-to-amplifier interconnection or

ground or bonding wire. Straigh forward formulas have been developed for various configurations. For a pair of conductors forming a cable (a balanced circuit with send and return wires), inductance depends on the spacing between conductors (determinate by the isulation thickness), the size of conductors (determinate by the Gauge and the length of cable. L= 0.004( ln(d/r+1/4+d/l)). L = l = d = r = ln =

inductance in microherry length of condustors in cm. center to center separation of conductors radius of condusctors in centimeters natural logarithm.

O.D.= Overall Diameter • B= Braided • S= Shield

CONDUCTOR STRENGTH

CONVERSION TABLE American wire gauge (AWG) – mm – mm2 AWG n°

Diam, mm

Area, mm

AWG n°

Diam, mm

Area, mm

AWG n°

Breaking strength [Kg]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

7,350 6,540 5,827 5,190 4,620 4,110 3,670 3,260 2,910 2,590 2,300 2,050 1,830 1,630 1,450 1,290 1,150 1,024 0,912 0,812

42,429 33,593 26,667 21,156 16,764 13,267 10,578 8,347 6,651 5,269 4,155 3,301 2,630 2,087 1,651 1,307 1,039 0,824 0,653 0,518

21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

0,7230 0,6440 0,5730 0,5110 0,4550 0,4050 0,3610 0,3210 0,2860 0,2540 0,2260 0,2030 0,1800 0,1600 0,1420 0,1270 0,1140 0,1020 0,0890 0,0790

0,4106 0,3257 0,2579 0,2051 0,1626 0,1288 0,1024 0,0809 0,0642 0,0507 0,0401 0,0324 0,0254 0,0201 0,0158 0,0127 0,0102 0,0082 0,0062 0,0049

14 16 18 20 22 24 26 28 30 32

56 36 23 14,8 9,2 5,7 3,7 2,1 1,4 0,91

2

www.referencelaboratory.com

2

SPEAKER CABLE SUGGESTED CONDUCTOR AREA Power amp range Cables run W

5m

10 m

20 m

10-40 50-100 100-500 500-1000

1 mm2 1,5 mm2 2,5 mm2 4 mm2

1 mm2 2 mm2 4 mm2 6 mm2

1,5 mm2 2,5 mm2 4 mm2 8 mm2

p.5

Shields, insulating materials and their properties BRAIDED A braided shield consists of two groups of thin wires wowen respectively in clockwise and counterclockwise fashion. The angle between two crossing strands is called the braid angle. Generally offers the best high-frequency shielding performance and protection from radio-frequency interference (RFI). This is due to the very high electrical conductivity of the braid, and to its low-inductance, selfshorting configuration. Moreover, the braided construction offers the highest structural integrity, good flexibility and flex life. LAP Spiral-wrapped copper serve shields are more inductive than braided shields, as they resemble a long coil of wire when extended. This can compromise high-frequency shielding and is not recommended when effective shielding above 100 kHz is required. Spiral shields are relatively inexpensive and easy to terminate, while guaranteeing the highest flexibility. FOIL SHIELDS Foil-shielded cable is very heavily used for permanent installation work and for portable multipaire "snake" cables. The light weight and slim profile makes foil very advantageous in applications involving pulling cable into conduit and permanent installations. The thin mylar/aluminium foil guarantees 100% coverage ratio and offers excellent RFI and EMI shielding properties, but is not suited for portable applications due to its shorter flex life. Cables with foil shields generally feature a drain copper wire used to terminate the shield and give extra mechanical strength to the cable. CONDUCTIVE PLASTICS Cables can feature conductive textile or plastic shields for 100% coverage, with copper drain wires or very low-coverage copper braid added for ease of termination and low DC resistance. While this type of construction is very flexible, its shielding effectiveness suffers greatly as frequency increases, offering very little effect above 10 kHz because of its low conductivity. Conductive plastic is therefore used in conjunction with traditional braided or spiral shields where flexibility should not compromise RFI and handling noise immunity. FILLERS, & HANDLING NOISE The audible effect(noise) that causes impactrelated "slapping" noise as the cable hits the stage or is stepped upon during use is related to capacitance, specifically the change in capacitance that takes place as the insulation or dielectric is deformed. This causes it to be have as a crude piezoelectric transducer, a relative of an electret condenser microphone. Handling noise is best addressed by using soft, impact-absorbing insulation and jacket materials in a very solid construction with ample cotton or plastic fillers to insure that the cable retains its shape. Tape wrapped around the outer shield greatly enhances solidness and electrical parameters uniformity along the cable. INSULATION MATERIALS depending on the specific application cables might employ a combination of different insulation materials to meet both electrical (i.e. capacitance) and mechanical (flexibility) demands. PVC, polyethylene (PE), and polypropylene (PP) are typically used. Reference cables employ special mixtures guaranteeing minimal shrinkage of the insulating sleeves during soldering operations.

INSULATION MATERIALS PROPERTIES PVC

Temp. range [°C] -20/80 Flame resistance Good Water resistance Good Abrasion resistance Good Low temp. flexibility Fair Solvent resistance Poor Mineral oils resistance Poor

#

1

-

1

PE

PP

-50/70 Poor Excellent Fair Excellent Fair Poor

-20/80 Poor Excellent Good Good Good Poor

3

f

TEFLON

POLYURETHANE

-40/200 Excellent Excellent Excellent Excellent Excellent Good

a

m

i

-40/80 Poor Good Good Good Excellent Excellent

l

y



s

c

a

b

l

e

www.referencelaboratory.com

p.6

Applications Quick Guide Family’s cables #1 #2 #3 #4 #5 #6 #7

#8 #9

Multicore AES/EBU-AES/EBU multicore Microphone - Microphone Quad Patch - Installation Instrument - Instrument Quad Speaker flexible Speaker superflexible

#10 #11 #12 #13

Speaker coax and Twin Data control - Dmx - Multicore light Power cables - Light-nex - Multimedia AC/Line Video - Composite Video Lszh - Security - Ethernet - Fire alarm Policab - Luflex - Polyurethane

GROUP MULTICORE Series Indoor Studio wiring

Indoor Broadcasting

Outdoor OB Van

Y Y Y Y Y Y

Y Y Y Y

Y Y Y

#1 RSMO RSC RSCQ RSCS RSF RSPFWJ RSPFCWJ #12 RSC/ZH RSC-S/ZH

Live

Y Y Y

Indoor fixed install.

Y Y Y Y Y Y

Indoor fixed install. LSZH compliant

Y Y

GROUP AES-EBU Series Indoor Studio wiring

Indoor Broadcasting

Outdoor OB Van

Y Y Y Y Y

Y Y Y Y Y

Y Y Y Y Y

Y

Y

Y Y

Pro Live

Studio & Broadcast

Outdoor (*) Delay line

Indoor fixed installation

Y Y Y Y Y Y Y

Y

Y

#2 RAC01 RAC02 RMC08 CP RMC10CP RM/AESEBU/S

Live

Indoor fixed install.

Y

GROUP MICROPHONE Series M.I. Market

#3 RMC01 RMC01TW RMC06 RMC13 PUR RMC14 RMC15TP RMC16TP RMLC02 RMLC03 RMLC04 RMLC05 RMCS01 RMIC01 RMIC01 NPI RMIC02 NPI RMCQ01 RMCQ02 RMCQ03TP #13 RMIC05 POLYCAB

Y

Y

Y

Y Y Y Y Y Y Y Y Y Y

Y Y Y Y

GROUP PATCH Series

#4 RPT01 RPF01 RPF02 RPF03 ROPF RMIC01

Studio

Live

Installation

Y Y Y Y Y

Y Y Y

Y Y Y Y Y

www.referencelaboratory.com

Internal Wiring

Y Y Y Y Y

Indoor fixed install. LSZH compliant

p.7

Applications Quick Guide NOTE: This Quick Guide is a general overview of cable groups. For specific models or and/or standard please follow the data sheet.

GROUP INSTRUMENT Series M.I. Market

#5 RIC01 RICO2 RIC05 RIC09T RIC-S01 RIC01A RICS01R RIC QUAD RICT RICTS

Pro Live

Studio & Broadcast

Bass Guitar

Electric Guitar

Y

Y

Y

Y

Y

Y

Y

Acoutic Guitar

Y Y Y Y Y Y Y

Y Y

Y

GROUP SPEAKERS Series Hi-Fi Market M.I. Market

#8 COAXIAL #7 RPC SUPERLEX RPC NPI RPCS RPCM #7 RPC MULTISTRAND RPC TP #8 RPC TW

Y Y

Live M.I.

Live Pro

Y Y Y

Y

Live Line Array

Studio Install

Fixed Inst. LSZH-NP

Y Y Y

Y

Y Y Y

Y

Y

Y

GROUP DMX Series Live

Teather

Studio

Y Y Y

Y

Y

Y Y Y

Y Y Y

Teather

Installation

Y Y

Y Y

Y

Y

#9 RDMX01 RDMX01/F RDMX01/SF RDMX01 PUR RDMX03 RDMX02 SF RDMX04

Y Y Y

GROUP AC/LINE Series Live

#10 RPLC SUPERFLEX RPLC NPI #12 RPLC ZH RLC #9 LIGHT NEX

Y

Y Y

GROUP VIDEO/COMPOSITE VIDEO Series #11 RVC01-02 RVC03-05 RVC50/20 RVC06 RVC07 RVC08 RVC09 COMPOSITE SUPERFLEX PVC COMPOSITE POLIURETHANE

Indoor

Outdoor Live

Y

Y

Y Y Y Y Y Y

Y Y Y Y Y Y Y

Critical temp

Broadcast Wired

Assembled

Y Y Y

Y Y

GROUP MULTIMEDIA CONTROL / SECURITY CONTROL/ FIRE ALARM Series #12 RPLC19-NPI RPLC10-NPI RCSRC01-& RCSR02 RFA (all models)

Installation Indoor

InstallationOutdoor

Y Y Y Y

Y Y Y Y

www.referencelaboratory.com

p.8

Index APPLICATIONS QUICK GUIDE

pag. 6

MULTICORE CABLES RSMO series - no isolated balanced pairs RSC series - isolated balanced pairs RSCS series - isolated balanced + overall screen RSCQ serie - quad

pag. 11 12 13 14

FOIL MULTICORE CABLES RSF series - pvc each balanced pairs RSFQ series - quad with pvc each quad RSP F WJ series RSP FC WJ series

pag. 15 16 17 18

AES EBU MULTICORE CABLES MULTICORE RM/AES/EBU/S series RAC series - single balanced RMC-CP series - single balanced

pag. 19 20 21

MICROPHONE & PATCHES CABLES RMC series RMLC series RMC-TP series - short pitch RMC-S series - solid RMCQ series - quad RMIC series - contractor market RPT series - patch cable RPF series - foil patch cable

pag. 22 24 25 25 26 27 28 29

INSTRUMENT CABLES RIC series RIC-S series - solid RIC-A series - for acoustic guitar VINTAGE series RIC-Q series - quad RICT series - twin for stereo keyboards RICTS series - twin hi fi market RPAV series - unbalanced audio + video

pag. 30 31 32 32 33 34 34 35

SPEAKER CABLES RPC series - no multistrand RPC series - multistrand RPCS series - overall shield RPCM series - twin RPCM series - twin hi fi RPCTP series - studio short pitch

pag. 36 39 40 41 43 44

AC LINE COMPOSITE CABLES RPLC series - power + balanced line

pag. 47

MULTIMEDIA CONTROL CABLES RPLC series - power + balanced line

pag. 48

SECURITY CONTROL CABLES RCSR series - power + video

pag. 48

FIRE ALARM CABLES RFA series

pag. 49

DMX CABLES DMX series RAMX/AC series - colour changer

pag. 50 50

LIGHT CABLES RLC series - multiwires power light

pag. 53

LIGHT-nex AC POWER CABLES RLCM-SF series - superflex multiwires RLCM-ZH series - multiwires AC Power LSZH

pag. 54 55

VIDEO CABLES RVC series

pag. 56

www.referencelaboratory.com

TRIAX series RS-VHS series - super VHS - multi minicoax RRGB series - multi mini mini coax AUDIO VIDEO SERVICE COMPOSITE CABLES RVAC series - multi coax + power RVCC series - composite Report set RVC Series - composite cables RGB/AC/C Series -coax RGB-Power ROB-C Series -Obvan application RFCB Series - fisher boom application VIC Series - conference room wiring INTERCOM CABLES RCOM series - 4 wires intercom field

59 60 60 pag. 61 62 63 64 67 68 69 69

LSZH CABLES Multicore audio cables series Speaker series Microphone series Video series

pag. 72 73 74 75

POLYCAB &POLYURETHANE CABLES RMC series RMCQ series RIC series RDMX series

pag. 77 77 77 77

ETHERNET CABLES Cat 5 series Cat 6 series Live series

pag. 78 79 79

ASSEMBLED CABLES pag. INSTRUMENT AND PEDAL - RIC series 84 INSTRUMENT - RIC-S series 85 INSTRUMENT - RIC-A series 86 INSTRUMENT - RIC-R series 87 INSTRUMENT - RIC-09T/HEAD - CABINET SPEAKER 88 MICROPHONE - RMC series 89 MICROPHONE - RMC TP series 90 MICROPHONE - RMC S series 90 MICROPHONE - RMCL series 90 DMX/HYBRID - DMX 91 SPEAKER - SP series 92 SPEAKER - line array series 93 SPEAKER MULTISTRAND - line array series 94 SPEAKER - for active Louspeakers - AC + Audio 95 CABLE DRUMS CABLE DURMS - RDC series - RDQC series BOX&PANEL CUSTOM SOLUTION - example of assembled Drums ACCESSORIES FOR CABLE DRUMS - soft cover EMPTY BOX AND PANELS - Reference full line

pag. 98 99 100 103 104

DISPLAY STAND FAI DA TE display stand PENGUIN STAND MICROSONIC universal monitor epic series

pag. 105 105 105

DI BOX PASSIVE DI BOX ACTIVE DI BOX PHANTOM POWER SUPPLY

pag. 106 107 107

AUDIO CONNECTOR CIRCULAR MULTIPIN - bayonet from 13 to 150 pins SPEAKER LIGHT - 19PIN Socapex compatible XLR - Male female with jaws ADAPTER - audio and DMX CHASSIS XLR PHONE PLUG - panel and fly RCA pin PHONE PLUG TM Series - jacks 1/4

pag. 108 110 111 111 112 112 113

ITALY

C A BL E S

D MA E I N

BULK CABLES

p.10

The Multicore cables family

R ef er en ce

La b

R LA

A pp lic at io n

the widest range to fit all the applications in LIVE and PRO AUDIO

RSPFWJ Series

Theatre & Studio Fixed Installation

pairs 4-6-8-10-12-16-20-24-28-32-36-40-48-56

RSPFC WJ Series

Theatre & Studio Fixed Installation

pairs 6-8-12-16-24-32-36-40-48-56

RSMO Series

Live Application

pairs 4-8-12-16-25-33-40-48

RSF Series

Broadcast/Live StudioTV & Fixed Installation

pairs 4-8-12-16-24-32-40-48-52

RSCS Series

Live & Studio Installation

pairs 4-8-12-16-25-33

RSC Series

Live & Studio Installation

pairs 4-6-8-10-12-16-20-24-28-32-36-40-48-56

RSCS ZH Series

Fixed Installation Series LSZH tested by

*

Fixed Installation Series LSZH tested by

*

pairs 4-8-12-16-25-33-56

RSC ZH Series

QUALITY SYSTEM CERTIFICATE

standard

pairs 4-8-12-16-25-33-40-48

RMAESEBU Series

Studio Installarion 110 Ω

pairs 4-8-12-16-25-33

ISO 9002/EN2902

RSCQ Series

Live & Studio Installation

pairs 4-8-12-16-25

RFL Series pairs 12

www.referencelaboratory.com

Studio Installation

p.11

MULTICORE cables

RSMO series #1

The RSMO Series of multichannel microphone cables provides a combination of thin profile, excellent flexibility, and high noise-rejection twisted pairs braided bare copper screened common shield. Overall cotton fillers wrapped in a tight spiral fashion provide extra compactness and uniform electrical and mechanical parameters along the cable. RSMO cables are intended for microphone and line level signals and suited for both indoor and outdoor applications. Typical applications: on stage and live sound reinforcement with central grounding.

REFERENCE • RSMO25

CONSTRUCTION and ORDERING Codes Suffix

Pairs Reel 4,8,12,16,25,33,40,48 100m and multiples Minimum bending radius = 15x Overall Diameter

RSMO

Colour Bk (black)

ELECTRICAL Capacitance cond/cond Capacitance cond/screen Cond. D.C.R. Screen type (each pair) Shield D.C.R. Nom. Impedance Working temp. range

70.65 [pF/m] 112 [pF/m] 0.088 [Ω/m] Red copper (braided 80%) 0.05 [Ω/m] 65 [Ω] -30 / +70 [°C]

MECHANICAL / PHYSICAL AWG # Strand Area [mm2]

O.D. [mm]

AWG 26 18/0.10 0.14 (tinned copper)

6 10 12 14 16 18 20.00 25.00

MODEL

Pairs

RSMO 4 RSMO 8 RSMO 12 RSMO 16 RSMO 25 RSMO 33 RSMO 40 RSMO 48

4 8 12 16 25 33 40 48

CORE N°

PAIR COLOUR

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

White

Red

Black

Yellow

Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange

CORE N° 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34

Ch. O.D. [mm] Insulation type O.D. incl. screen [mm]

Weight [Kg/Mt]

1.0 PVC 2.2

0.07 0.10 0.19 0.24 0.34 0.43 0.49 0.56

PAIR COLOUR Yellow

Pink

Purple

Green Green Green Green

White White White White

Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Grey Brown Blue Orange Green Brown

CORE N° 35 36 37 38 39 40 41 42 43 44 45 46 47 48

PAIR COLOUR Green Black Black Black Black Black Blue Blue Blue Blue Blue Blue Blue Blue

White White White White White White White White White White White White White White

Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green

www.referencelaboratory.com

p.12

MULTICORE cables

RSC series #1

The RSC Series of multichannel microphone cables offers a combination of thin profile, excellent flexibility, and very high noise-rejection. RSC cables are intended for microphone and line level signals and suited for both indoor and outdoor applications. Channel pairs are individually shielded and insulated with a special PVC jacket. Each pair features a drain wire for a faster and easier connection. Three identification codes guarantee safe ‘last minute’ installations: pair colour, single conductor colour, and pair-jacket ID-number. TNT tape gives extra solidness to the cable structure and contributes to have constant capacity figures along the cable even under “heavy handling” situations. Typical applications: studio installation, mobile units and outdoor broadcasting, sound reinforcement and live events.

REFERENCE • RSC25

CONSTRUCTION and ORDERING Codes Suffix

Pairs Reel 2,4,6,8,12,16,20,25 100m and multiples 33,36,40,48,56 Minimum bending radius = 20x Overall Diameter

RSC

Colour Bk (black)

ELECTRICAL Capacitance cond/cond Capacitance cond/screen Cond. D.C.R. Screen type (each pair) Shield D.C.R. Nom. Impedance Attenuation @ 1MHz Working temp. range

80 [pF/m] 150 [pF/m] 0.083 [Ω/m] Tinned copper (lap 85%) 0.04 [Ω/m] 75 [Ω] 2.1 [dB/100m] -15 / +70 [°C]

MECHANICAL / PHYSICAL AWG # Strand Area [mm2]

MODEL

Pairs

RSC 2 RSC 4 RSC 6 RSC 8 RSC 12 RSC 16 RSC 20 RSC 25 RSC 33 RSC 36 RSC 40 RSC 48 RSC 56

2 4 6 8 12 16 20 25 33 36 40 48 56

CORE N°

POSITIVE WIRE COLOURS Brown Red Orange Yellow Green Blue Purple Grey White Black Brown Red Orange Yellow Green Blue

Channel

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Drain wire

AWG 24 AWG 24 28/0.10 7/0.18 0.22 0.20 (Red (tinned copper) copper)

CORE JACKET COLOURS

White

Grey

www.referencelaboratory.com

CORE N° 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

O.D. [mm]

Ch. O.D. [mm]/ insul.type Pair O.D. [mm]/insul. type

Weight [Kg/Mt]

1.0 / PE 2.5 / PVC

0,08 0,097 0,102 0,249 0,284 0,392 0,600 0,620 0,749 0,820 0,908 1,081 1,270

8,2 9 10 11,2 15,5 16,8 19,4 21,5 23 24 25,2 28,50 32,6 POSITIVE WIRE COLOURS Purple Grey White Black Brown Red Orange Yellow Green Blue Purple Grey White Black Brown Red

CORE JACKET COLOURS Grey

Red

Orange

CORE N° 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49/56

POSITIVE WIRE COLOURS Orange Yellow Green Blue Purple Grey White Black Brown Red Orange Yellow Green Blue Purple Grey same above

CORE JACKET COLOURS

Orange

Yellow

Brown

p.13

MULTICORE cables

RSCS series #1

The RSCS Series of multicore microphone cables offers a combination of thin profile, excellent flexibility, and very a high noise-rejection. RSCS cables are intended for both microphone and line level signals and they can be used with confidence both indoor and outdoor. Channel pairs are individually shielded and insulated with a special PVC jacket. A drain wire is provided for each pair for fast and easy connections. TNT tape gives extra solidness to the cable structure and contributes to have constant capacity figures along the cable, while preventing pair twisting over time. The overall braided shield gives a superior noise immunity creating a second barrier to the external interference. Three identification codes gives extra confidence in ‘last minute’ installations: pair colour, single conductor colour, and pair-jacket ID-number. Typical applications: studio installation, mobile units and outdoor broadcasting, sound reinforcement and live events.

REFERENCE • RSCS25

CONSTRUCTION and ORDERING Codes Suffix

Pairs 4,8,12,16,25,33

RSCS

Reel 100m and multiples

Colour Bk (black)

Minimum bending radius = 20x Overall Diameter

ELECTRICAL Capacitance cond/cond Capacitance cond/screen Cond. D.C.R. Screen type (overall) Screen type (each pair) Shield D.C.R. Nom. Impedance Attenuation @ 1MHz Working temp. range

80 [pF/m] 150 [pF/m] 0.083 [Ω/m] Tinned copper (braided 80%) Tinned copper (lap 85%) 0.04 [Ω/m] 75 [Ω] 2.1 [dB/100m] -15 / +70 [°C]

MECHANICAL / PHYSICAL MODEL

AWG # Strand Area [mm2]

Pairs

Channel RSCS RSCS RSCS RSCS RSCS RSCS

4 8 12 16 25 33

4 8 12 16 25 33

Drain wire

AWG 24 AWG 24 28/0.10 7/0.18 0.22 0.20 (tinned (tinned copper) copper)

CORE N°

POSITIVE WIRE COLOURS

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Brown Red Orange Yellow Green Blue Purple Grey White Black Brown Red Orange Yellow Green Blue

CORE JACKET COLOURS

White

Grey

O.D. [mm]

Ch. O.D. [mm]/ insul.type Pair O.D. [mm]/insul. type

Weight [Kg/Mt]

1.0 / PE 2.5 / PVC

0,125 0,247 0,329 0,397 0,582 0,779

9,80 13,80 16,50 16,70 21,50 24

CORE N°

POSITIVE WIRE COLOURS

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

Purple Grey White Black Brown Red Orange Yellow Green Blue Purple Grey White Black Brown Red

CORE JACKET COLOURS Grey

Red

Orange

CORE N°

POSITIVE WIRE COLOURS

33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Orange Yellow Green Blue Purple Grey White Black Brown Red Orange Yellow Green Blue Purple Grey

CORE JACKET COLOURS

Orange

Yellow

www.referencelaboratory.com

p.14

QUAD MULTICORE cables

RSCQ series #1

The RSCQ Series is the excellent solution for professional application. It is a combination of thin profile, excellent flexibility have very high noise-rejection and suited for both indoor and outdoor applications. Channel pairs are individually shielded and insulated with a special PVC jacket. This four-conductor-shielded configuration can best be thought of as two twisted pairs twisted together an is very popular in applications such as television production,where huge amounts of power cable for lighting and camera equipment surround the performer. The quad reduce the electromagnetic interference (EMI) is improved by a factor of ten (20 dB). Typical applications: studio installation, mobile units and outdoor broadcasting.

CONSTRUCTION and ORDERING Codes Suffix

Pairs Reel 12 100m and multiples Minimum bending radius = 22x Overall Diameter

RSCQ

Colour Bk (black)

ELECTRICAL Capacitance cond/cond Capacitance cond/screen Cond. D.C.R. Screen type (each pair) Shield D.C.R. Nom. Impedance Inductance Working temp. range

63 [pF/m] 107 [pF/m] 0.083 [Ω/m] Bare copper braid 0.04 [Ω/m] 80 [Ω] 06mH/km -40 / +80 [°C]

MECHANICAL / PHYSICAL MODEL

AWG # Strand Area [mm2]

Channel RSCQ 12

AWG 24 18/0.10 0.22 (tinned copper)

www.referencelaboratory.com

Shield

O.D. [mm]

Ch. O.D. [mm]/ insul.type Pair O.D. [mm]/insul. type

18 Bare Copper Braid

Weight [Kg/Mt] 0,11

1.0 / XLPE 3.2 / PVC

p.15

MULTICORE cables

RSF series

W/JACKET & FOIL

#1

The RSF Series of multichannel microphone cables provides a combination of thin profile, excellent flexibility, and very low noise-rejection figures. They are intended for microphone and line level signals and suited for both indoor and outdoor applications. RSF multichannel cables are composed of foil screened twisted pairs with an individual PVC outer jacket for those applications where mechanical robustness is at premium. TNT tape gives extra solidity to the cable and contributes to have a constant capacity figure along the cable, while maintaining the round shape of the cable over time. Pair jackets have individual ID-numbers printed on. Foil screen can be easily removed and each pair also has a highly conductive stranded drain wire for easier screen termination and on the fly soldering operations. Individually shielded and insulated pairs. Typical applications: Studio installation, Theatre installation, Broadcasting mobile unit wiring, Conference room installation, Church installation.

REFERENCE • RSF12

CONSTRUCTION and ORDERING Codes Suffix

Pairs Reel 4,8,12,16,24,32,40,48,52 100m Minimum bending radius = 20x Overall Diameter

RSF

Colour GN(green) and BK(black)

ELECTRICAL Capacitance cond/cond Capacitance cond/screen Cond. D.C.R. Screen type (each pair) Shield D.C.R. Nom. Impedance Attenuation @ 1MHz Working temp. range

120 [pF/m] 360 [pF/m] 0.09 [Ω/m] Al-My foil (100%) 0.04 [Ω/m] 55 [Ω] 2.1[dB/100m] -30 / +70 [°C]

MECHANICAL / PHYSICAL MODEL

Pairs

AWG # Strand Area [mm2]

Channel RSF RSF RSF RSF RSF RSF RSF RSF RSF

04 08 12 16 24 32 40 48 52

4 8 12 16 24 32 40 48 52

Ch. O.D. [mm]/ insul.type Pair O.D. [mm]/insul. type

Weight [Kg/Mt]

1.0 / PP 2.7 / PVC

0,086 0,160 0,223 0,334 0,451 0,575 0,680 0,831 1,100

Drain wire

AWG 26 AWG 24 18/0.10 7/0.18 0.22 0.22 (red (tinned copper) copper)

RSF-L is a version of RSF family with polyolephine insulation for have best performance with less overall diameter

RSF 12 L

O.D. [mm] 9 11,8 15 17,5 21,6 22,7 24,5 27,5 31

MODEL RSF12L - MECHANICAL/PHYSICAL Inner Conductor Bare Copper 28x0,10 mm cross section 0,22mm2 Insulation Polyolephine Ø=1,00 mm Color conductor Natural/Red Core arrangement 2 conductors twisted in pairs Drain Wire Tinned Copper7x0,18 mm Pair Shield Blu Alu Foil coverage 100% Pair jacket Grey flexible PVC Tape Non wovens under jacket Jacket Black Flexible PVC Ø=12,80 mm Weight 180 Kg/Km

www.referencelaboratory.com

p.16

QUAD MULTICORE cables

RSFQ series #1

The RFQ Series is the excellent solution for professional application. It is a combination of thin profile, excellent flexibility have very high noise-rejection and suited for fixed installation Channel pairs are individually shielded and insulated with a special PVC jacket. This four-conductor-shielded configuration can best be thought of as two twisted pairs twisted together an is very popular in applications such as television production,where huge amounts of power cable for lighting and camera equipment surround the performer. The quad reduce the electromagnetic interference (EMI) is improved by a factor of ten (20 dB). Typical applications: studio installation, broadcasting studio installation, OB van wiring.

CONSTRUCTION and ORDERING Codes Suffix

Pairs Reel 12 100m and multiples Minimum bending radius = 20x Overall Diameter

RSFQ

Colour Bk (black)

ELECTRICAL Capacitance cond/cond Capacitance cond/screen Cond. D.C.R. Screen type (each pair) Isulation resistence Nom. Impedance Inductance Working temp. range

63 [pF/m] 107 [pF/m] 0.083 [Ω/m] Blu alu-foil coverage 100% >100MOhm/Km 80 [Ω] 06mH/km -40 / +80 [°C]

MECHANICAL / PHYSICAL MODEL

RSFQ 12

AWG # Strand Area [mm2] Channel Shield

O.D. [mm]

Ch. O.D. [mm]/ insul.type Pair O.D. [mm]/insul. type

Weight [Kg/Mt]

AWG 24 18/0.10 0.22 ALU-FOIL (tinned copper)

17

1.0 / XLPE 3.2 / PVC

0,021

www.referencelaboratory.com

p.17

MULTICORE cables

RSP F WJ series

W/O JACKET & FREE EDGE

#1

The RSPFWJ Series of multichannel microphone cables provides a combination of very thin profile, excellent flexibility, and very high noise-immunity. They are intended for microphone and line level signals and suited for both indoor and outdoor installations. RSFPWJ multichannel cables feature individually foil(blue finish) FREE EDGE screened twisted pairs. Foil screen can be easily removed and each pair also has a highly conductive stranded drain wire for screen termination and easier last-minute soldering operations. TNT tape gives extra solidity to the cable and contributes to have a constant capacity figure along the cable, while maintaining cable roundness over time. Individually shielded pairs Typical applications: Studio wiring, Theatre wiring, Broadcasting mobile unit wiring, Conference room wiring.

CONSTRUCTION and ORDERING Codes Suffix RSP F WJ

Pairs 4,6,8,10,12,16,20,24,28, 32,36,40,48,56

Reel 100m and multiples, max 600mt

Colour Bk (black), Gr (grey)

ELECTRICAL Capacitance cond/cond Capacitance cond/screen Cond. D.C.R. Insul./Screen type (each pair) Shield D.C.R. Nom. Impedance Attenuation @ 1MHz Working temp. range

95 [pF/m] 180 [pF/m] 0.09 [Ω/m] My-Al-My foil (100%) 0.04 [Ω/m] 70 [Ω] 2.1[dB/100m] -30 / +70 [°C]

MECHANICAL / PHYSICAL MODEL

Pairs

RSPFWJ 4 RSPFWJ 6 RSPFWJ 8 RSPFWJ 10 RSPFWJ 12 RSPFWJ 16 RSPFWJ 20 RSPFWJ 24 RSPFWJ 28 RSPFWJ 32 RSPFWJ 36 RSPFWJ 40 RSPFWJ 48 RSPFWJ 56

4 6 8 10 12 16 20 24 28 32 36 40 48 56

CORE N° 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

AWG # Strand Area [mm2] Channel Drain wire

AWG 24 7/0.20 0.22 (tinned copper)

PAIR COLOURS Blue Orange White Green Brown Grey Blue Orange Green Red Brown Grey Blue Orange Green Black Brown Grey

AWG 24 7/0.20 0.22 (tinned copper)

CORE N° 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

O.D. [mm] 8 9.2 9.9 11.5 11.5 13.6 15 15.7 18.2 18.5 19.7 20.3 22 23.5

PAIR COLOURS Blue Orange Yellow Green Brown Grey Blue Orange Green Purple Brown Grey Blue Orange Green Pink Brown Grey

CORE N° 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

Ch. O.D. [mm]/ insul.type Pair O.D. [mm]/screen-insul. type

Weight [Kg/Mt]

1.1 / PE 2.3 / My-Al-My PVC

0.071 0.105 0.118 0.160 0.162 0.236 0.290 0.312 0.390 0.384 0.465 0.543 0.595 0.680

PAIR COLOURS Red White Black Black Yellow Purple White Pink Black Yellow Red Purple Pink Yellow Purple Black Pink Purple Yellow Pink Purple

CORE N° 46 47 48 49 50 51 52 53 54 55 56

PAIR COLOURS Blue Orange Green Brown Grey White Red Transparent Black Yellow Purple Pink

www.referencelaboratory.com

p.18

MULTICORE cables

RSP FC WJ series

FOIL

#1

A cable series featuring very thin profile, excellent flexibility, and high noise-immunity. Intended for microphone and line level signals and suited for both indoor and outdoor installations. Pairs are individually foil (gold finish) screened. Foil screen can be easily removed and each pair also has a highly conductive stranded drain wire for screen termination and easier last-minute soldering operations. TNT tape gives extra solidity to the cable and contributes to have a constant capacity figure along the cable, while maintaining cable roundness over time. Typical applications: Studio wiring, Theatre wiring, Broadcasting studio wiring, Conference room wiring, fixed installation wiring. Mobile units wiring.

REFERENCE • RSP FC WJ 08

CONSTRUCTION and ORDERING Codes Suffix

Pairs

RSP FC WJ

Reel

100m and multiples, 6,8,12,16,24,32,36, 40,48,56 max 600mt Minimum bending radius = 25x Overall Diameter

Colour Bk (black)

ELECTRICAL Capacitance cond/cond Capacitance cond/screen Cond. D.C.R. Insul./Screen type (each pair) Insulation resistance Working temp. range

52 [pF/m] 89 [pF/m] 10000 [MΩ/km] -30 / +70 [°C]

MECHANICAL / PHYSICAL MODEL RSP FC WJ 6 RSP FC WJ 8 RSP FC WJ 12 RSP FC WJ 16 RSP FC WJ 24 RSP FC WJ 32 RSP FC WJ 36 RSP FC WJ 40 RSP FC WJ 48 RSP FC WJ 56 CORE N° 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Pairs AWG # Strand Area [mm2] Channel Drain wire 6 8 AWG AWG 12 24 24 16 7/0.20 7/0.20 24 0.22 0.22 32 (bare (tinned 36 copper) copper) 40 48 56

PAIR COLOURS Blue Orange White Green Brown Grey Blue Orange Green Red Brown Grey Blue Orange Green Black Brown Grey

CORE N° 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

www.referencelaboratory.com

Cond. insul.type Pair screen- type Outer jacket insul. type

O.D. [mm] 9,60 10,20 11,60 13,00 15,00 16,60 19,50 17,80 22,30 25,30

PAIR COLOURS Blue Orange Yellow Green Brown Grey Blue Orange Green Purple Brown Grey Blue Orange Green Pink Brown Grey

0,115 0,132 0,172 0,218 0,291 0,361 0,408 0,418 0,487 0,575

XPLE Al-PE TNT tape + PVC

CORE N° 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

PAIR COLOURS Red White Black Black Yellow Purple White Pink Black Yellow Red Purple Pink Yellow Purple Black Pink Purple Yellow Pink Purple

Weight [Kg/Mt]

CORE N° 46 47 48 49 50 51 52 53 54 55 56

PAIR COLOURS Blue Orange Green Brown Grey White Red Transparent Black Yellow Purple Pink

p.19

AES-EBU MULTICORE cables

RM/AESEBU/S series

The multicore RM/AESEBU/S series is a new 110 Ohm balanced audio cable designed for digital audio data transmission over AES-EBU standard. Relevant attention has been paid to the electrical/mechanical characteristics to ensure that signal remain error free even in long distance.The special formula of the jacket material guarantees an outstanding flexibility even under critical working conditions, such as during on-location recording and live events. Typical applications: Recording Studio, Broadcasting ,TV and Conference room wiring.

CONSTRUCTION and ORDERING Codes Suffix RM/AESEBU/S

Pairs Reel 4,8,12,16,20 100m Minimum bending radius = 20x Overall Diameter

Colour Bk (black)

ELECTRICAL Capacitance cond/cond Capacitance cond/screen Screen type (each pair) Shield D.C.R. Nom. Impedance

44 [pF/m] 68 [pF/m] ALU FOIL coverage 100% na [Ω/m] 110 [Ω]

Attenuation @ 1MHz

< 2 [dB/100m]

Inductance Working temp. range

8000 0,6 90 >8000 0,7 120 >8000 0,6 110 >9000 0,6 90 >7000 NA 110 >7000

Overall diam[mm]

Weight [Kg/100Mt]

Super Flex PVC

6,5

5

-25 / +70

Super Flex PVC + overall tweed fabric Flex PVC

6,8

6,3

-25 / +70

7

6,7

-25 / +70

Antistatic PVC

6,5

6,8

-25 / +70

6

4,64

-40 / +80

5,80

4,3

-25 / +70

Jacket material

Polyurethane 32N/mmq Super Flex PVC

Working temp [°C]

Minimum bending radius = 10x Overall Diameter

www.referencelaboratory.com

p.24

MICROPHONES cables

RMCL series #3

The RMLC is a standard microphone cable series designed for general audio applications. A special insulating material guarantees an outstanding flexibility, even under extreme environmental conditions, as during on-location recording and live events. RMLC series adds a superior sonic quality to the above features, thanks to the high quality and cost-effective optimised construction process: lower capacity with improved flexibility and mechanical reliability over time! Typical applications: microphone and patch connections, XLR extension cable, Line level connections, Intercom connections.

RMLC 02

RMLC 03

RMLC 04

RMLC 05

CONSTRUCTION and ORDERING Codes RMLC RMLC RMLC RMLC

Model 02 03 04 05

Reel lenght 100 m

Colours

Weight Kg/100Mt 4,3 4,4 4,4 4,6

Bk (black) Bk (black) Bk (black) Bk (black)

CONSTRUCTION / MECHANICAL Model

AWG # ; Area [mm2] Strand

RMLC 02

AWG 24 ; 0,22 red copper AWG 24 ; 0,22 red copper AWG 24 ; 0,22 red copper + drain wire AWG 24 ; 0,22 red copper

RMLC 03 RMLC 04 RMLC 05

Insulation material PE Polyolephine Polyolephine PE

Shield Braid (red copper) Lap (inend copper) Lap (tinned copper) Braid (tinned copper)

ELECTRICAL Model

Cond. D.C.R. Cap. cond/cond Cap. cond/shield Inductance [pF/m] [pF/m] [mH/Km] Ω/m] [Ω

JACKET

O.D.

Insulation resistance Ω/Km] [MΩ

RMLC 02

0,085

56

98

0,7

Flex PVC

5.80

>10000

RMLC 03

0,085

55

85

0,6

Superflex PVC

6.20

>10000

RMLC 04

0,085

64

109

NA

Flex PVC

6.0

>10000

RMLC 05

0,085

58

91

NA

Flex PVC

6.10

>7000

Minimum bending radius = 10x Overall Diameter www.referencelaboratory.com

p.25

MICROPHONES cables

RMC-TP series #3

Innovative microphones serie for two models with shorter twist pitch (TP) with “Hi Braid Coverage & Hi Standing Angle”. Long distance Benefit: better conducibility and less HF attenuation. Typical Applications: Pro Audio “LIVE” & “STUDIO”

RMC15 TP

REFERENCE

Colour Black/Grey

TP

ELECTRIC CHARACTERISTIC

CONSTRUCTION 2x0,14

Inner conductor Insulation Core arrang. Tape Shield Jacket Weight

COLOUR and PACKAGE Reel 100mt

Bare Copper Cross Section 0,14 mm2 Polyolephine Ø=1,00mm nat/red 2 Twisted conductors with fillers Non wovens Tinned Copper Braid coverage>90% Super flex PVC Ø=4,60mm Black 37 Kg/Km

Cond.Ohm resistance Insulation resistance at 20°C Capacitance Cond/cond. Capacitance Cond/shield Twist pitch TP Temperature range

Typical Applications: Pro Audio “LIVE” & “STUDIO” longest distances/long lifetime

>134 Ohm/Km >10.000Mohm*Km 66 pF/m 104 pF/m 18 mm -25°C/+70°C

COLOUR and PACKAGE Reel 100mt

RMC16 TP

Colour Black/Blue

ELECTRIC CHARACTERISTIC

CONSTRUCTION 2x0,34

Inner conductor Insulation Core arrang. Tape Shield Jacket Weight

Bare Copper Cross Section 0,34 mm2 PE Ø=1,70 mm nat/red 2 Twisted conductors with fillers Non wovens Tinned Copper Braid coverage>94% Superflex PVC Ø=6,00 mm Black 57 Kg/Km

Cond.Ohm resistance Insulation resistance at 20°C Capacitance Cond/cond. Capacitance Cond/shield Twist pitch TP Temperature range

MICROPHONES cables

>56 Ohm/Km >10.000Mohm*Km 67 pF/m 106 pF/m 20 mm -25°C/+70°C

RMC-S series #3

The RMC-S is a solid copper microphone cable designed for HI-End pro audio applications. A special insulating material guarantees an outstanding flexibility, even under extreme environmental conditions, as during on-location recording. RMC-S series adds a superior sonic quality to the above features, thanks to the solid technology. Typical applications: HI-End Pro audio, Studio applications.

RMC-S01

CONSTRUCTION / MECHANICAL and ELECTRIC CHARACTERISTIC Inner conductor Insulation Filler Shield 1 Shield 2 Jacket Cond/Cond resistance Insulation resistance Temperature range

Solid bare copper AW20 Foam PE 2,30mm Polyprophilene Semiconductor tape Tinned copper braid Black PVC superflex 0,77mm < 0,004 Ohm/Mt < 10000MOhm/Km -25 / +70 [°C]

Overall diameter 6.80mm

www.referencelaboratory.com

p.26

QUAD MICROPHONES cables

RMCQ series #3

DO USE THE QUAD This four-conductor-shielded configuration can best be thought of as two twisted pairs twisted together. Using four small conductors in place of two large ones allows the loop area of the cable to be further reduced and its rejection of electromagnetic interference (EMI) shows a 20dB improvement. This makes star-quad cable very popular for microphones and balanced lines used in critical applications such as television production, where huge amounts of power cable for lighting and camera equipment surround the performers. Intermodulation distortion is also greatly reduced. Besides that, using two 24 AWG conductors connected in parallel to replace each of the conductors of a 22 AWG twisted pair will result in the same DC resistance, but approximately half the series inductance. This will result in improved high-frequency performance: better clarity without the need for equalization to boost the high end. The significance of skin effect, and therefore the phase shift along the cable, is greatly reduced and this is a great benefit when clarity and coherence of high-frequency complex waveforms is to be considered. While the improvement may not be as dramatic as changing the microphone, the benefits from using quad cables cannot be neglected any more when professional microphone connections are needed. RMCQ01 is the result of an accurate design which, together with the usual high quality construction featured by Reference cables (drain wire with braided high coverage screen, tight bundle and high flexibility), focused on the right number of twists per unit length: with zero twists we would have a nice receiving antenna! Key features Higher noise immunity (>98%), from RFI to EMI to low frequency power-line hum. Improved sound quality. Antistatic PVC material: no dust, nor shake noise or induced noise from electrostatic fields. Typical applications: OB van, studio recording, broadcast and live show.

REFERENCE • RMCQ 01

RMCQ 01

RMCQ 02

RMCQ 3TP

CONSTRUCTION and ORDERING Codes Model RMCQ 01 RMCQ 02 RMCQ 03TP

Reel lenght 100 m 100 m 100 m

Colours Bk (black) Bk (black) Bk (black)

ELECTRICAL & PHYSICAL Capacitance cond./screen Inductance Cond. D.C.R. Screen type Shield D.C.R. Nom. Impedance Insulation material Test voltage Insulation resistance Drain wire AWG # / Area [mm2] Strand O.D. / Overall jacket insulation material Working temp. range www.referencelaboratory.com

RMCQ 01 RMCQ 02 86 [pF/m] 86 [pF/m] 10000 > 10000 www.referencelaboratory.com

p.28

PATCH cables

RPT series #4

The RPT series is designed to provide high quality electric/electronic instrument and outboard connections, for recording, home, and post-pro studio applications, processing units and mixer-to-jack-panel wiring tasks. A very highdensity shield provides maximum protection from electrostatically induced hum and buzz. Cotton fillers and soft PVC guarantees a tight bundle while retaining good flexibility and handling properties. Typical applications: patch cord cable.

REFERENCE • RPT 01 RPT 01

CONSTRUCTION and ORDERING Codes Model RPT 01

Reel lenght

Colours Rd (red), Bk (black), Bl (blue), Yl (yellow)

100 m

SPECIFICATIONS AWG# / Area Q.ty / mm

RPT 01 AWG22 / 0,28 2 x 44 x 0,10 (red copper) PVC HT105° PVC Lap (red copper) 106 180 59 4,80 22 -30/+70

[mm ] [mm] 2

Signal pair insulation Outer jacket material Screen type Capacitance cond/cond Capacitance cond/screen Nom. Impedance Overall diameter Weight Working temp

(pF/m) (pF/m) (Ω) [mm] [Kg/Km] °C

PATCH cables

ROPF series #4

ROPF01 is a thin profile balanced cable intended for permanent and semi-permanent patch connections. The foil shield gives superior protection for applications where EMI interference is a major worry and does not include the drain wire, which provides an easy screen termination and good mechanical reliability. Constant electrical parameters along the cable and the 100 ohm impedance results in superior sonic transparency. Typical applications: Studio installation, Broadcasting and mobile units, Conference room.

REFERENCE • ROPF 01

ROPF 01

CONSTRUCTION and ORDERING Codes Model ROPF 01

Reel lenght 100 m

Colours Bk (black)

SPECIFICATIONS AWG# / Area Strand Signal pair insulation Outer jacket material Screen type

Capacitance cond/cond Capacitance cond/screen Nom. Impedance O.D. Weight Working temp www.referencelaboratory.com

[mm2] [mm]

(pF/m) (pF/m) (Ω) [mm] [Kg/Km] °C

AWG24 / 0,22 2 x 7 x 0,20 (tinned copper) PVC Flexible PVC Al/My foil around the pair (conductive edge)+ drain wire (AWG24 / 0,22; tinned copper) 98 180 100 3,90 20,55 -30/+80

p.29

PATCH cables

RPF series #4

The RPF series is designed to provide high quality balanced connections for recording, home, and post-pro studio applications, processing units and mixer-to-jack-panel wiring tasks. The foil shield of RPF01 provides maximum protection from electrostatically induced hum and buzz. The lap shield of RPF02 guarantees 100% optical coverage and noise immunity over a wide range of frequencies, while retaining the mechanical properties ideal for live applications. Models of RPF Series achieve the best compromise between thin profile, electrical properties and mechanical reliabilty over time. Typical applications: electronic equipment internal wiring, rack and console wiring (RPF02), studio and conference room, fixed installations (RPF01).

REFERENCE • RPF 01

RPF 01

REFERENCE • RPF 02

RPF 02

REFERENCE • RPF 03

RPF 03

CONSTRUCTION and ORDERING Codes Model RPF 01 RPF 02 RPF 03

Reel lenght 100 m 100 m 100 m

SPECIFICATIONS AWG# / Area Strand Signal pair insulation Outer jacket material Screen type Capacitance cond/cond Capacitance cond/screen Drain wire (tinned copper) Overall diameter Weight Working temp

[mm2] [mm]

(pF/m) (pF/m) 54 [mm] [Kg/100Mt] °C

Colours Gr (grey) Bk (black) Bk (black)

RPF 01

RPF 02

RPF 03

AWG26 / 0,14 18 x 0,10 PVC Flexible PVC Al/My foil 110 240 7 x 0,10 2,70 1,270 -30/+70

AWG26 / 0,14 18 x 0,10 PE Flexible PVC Lap (red copper) 80 150 7 x 0,15 2,80 1,110 -30/+70

AWG26 / 0,14 18 x 0,10 PVC Flexible PVC Lap (red copper) 52 89 7 x 0,15 3,20 1,220 -30/+70

www.referencelaboratory.com

p.30

INSTRUMENTS cables

RIC series #5

The RIC Series is intended for electric/electronic instrument, effect units, and many unbalanced connections. They represent the best choice for all guitar and bass guitar. The polyethylene conductor insulation provides low capacitance and impedance values. The conductive plastic sheath inside the screen improves handling noise immunity due to internal static charges, while a very high density overall shield provides maximum protection from induced hum and buzz. Typical applications: Instrument cable, line unbalanced cable, electric guitar cable, acustic guitar cable, bass guitar cable, foot pedal connection and all acustic intrument with pick up.

RIC 01

RIC 02

RIC 05

RIC 09 T

CONSTRUCTION and ORDERING Codes Model

Reel lenght

RIC 01 RIC 02 RIC 05 RIC 09 T

100 m

Colours Bk (black), Bl (blue) ON REQUEST: Gr (grey), Gn (green), Br (brown), Bl (blue), Rd (red) Bk (black) ON REQUEST: Gr (grey), Gn (green), Br (brown), Bl (blue), Rd (red) Bk (black) ON REQUEST: Gr (grey), Gn (green), Br (brown), Bl (blue), Rd (red) Transparent

ELECTRICAL MODEL

Conductor D.C.R. Ω/m] [Ω

Shield D.C.R. Ω/m] [Ω

Cap. cond/shield [pF/m]

Impedance Ω] [Ω

RIC 01 RIC 02 RIC 05 RIC 09 T

0.016 0.07 0.05 100

-30/+70

7

8,5

>100

-30/+70

8,4

11,5

>100

-30/+70

11

20,7

>100

-30/+70

12

24,5

(>100)+ (>60)

-30/+70

12,2

23,2

AWG# / Area* Strand

Cond. D.C.R. Ω/Km] [Ω

Jacket

2 x 2,5 (AWG13) 80 x 0,20 red cop. 4 x 2,5 (AWG13) 48 x 0,25 red cop. 2 x 1,5 (AWG15) 48 x 0,20 red cop. 2 x 0,75 (AWG19) 20 x 0,20 red cop. 2 x 1 (AWG18) 30 x 0,20 red cop. 2 x 1,5 (AWG15) 29 x 0,25 red cop. 2 x 2,5 (AWG13) 48 x 0,25 red cop. 4 x 2,5 (AWG13) 48 x 0,25 red cop. 8 x 1,5 (AWG15) 29 x 0,25 red cop. 2 x 2,5 (AWG13) + 2 x 4 (AWG11) 80 x 0,20 red cop.+ 90 x 0,25 red cop.

1KV.

RPCM L series

LOUDSPEAKER TWIN cables

#8

New line of TWIN speaker cable with transparency jacket fumè. Typical Applications: for medium budget, Hi Fi and audio Installations.

RPCML 06

COLOUR and PACKAGE Reel 100mt Colour Fumè Transparent - White

CONSTRUCTION 2x1,50 Inner conductor 1 Bare Copper 48x0,20 Tinned copper 48x0,20 Inner conductor 2 PVC Flexible Ø=2,80x5,60 Jacket 40 Kg/Km Weight

ELECTRICAL CHARACTERISTICS Ohmic resistance max 22 Mohm x Km 16,5A Power rating -40°C +70°C Temperature range Static -20°C +70°C Flexing

CONSTRUCTION 2x0.75 Inner conductor 1 Bare Copper 23x0,20 Tinned copper 23x0,20 Inner conductor 2 PVC Flexible Ø=2,2x5 Jacket 20 Kg/Km Weight

ELECTRICAL CHARACTERISTICS Ohmic resistance max 20 Mohm x Km Power rating 6A Temperature range Static -40°C +70°C Flexing -20°C +70°C

CONSTRUCTION 2X1.0 Inner conductor 1 Bare Copper 31x0,20 Tinned copper 31x0,20 Inner conductor 2 PVC Flexible Ø=2,5x5,5 Jacket 30 Kg/Km Weight

ELECTRICAL CHARACTERISTICS Ohmic resistance max 20 Mohm x Km Power rating 10A Temperature range Static -40°C +70°C Flexing -20°C +70°C

RPCML 08 COLOUR and PACKAGE Reel 100mt Colour Fumè Transparent - White

RPCML 09 COLOUR and PACKAGE Reel 100mt Colour Fumè Transparent - White

www.referencelaboratory.com

p.43

LOUDSPEAKER TWIN cables

RPC-TW series #8

A dedicated “Twin Speaker Cable” line well designed to meet the faster installation because the twin’s construction besides white finish to allowe the full integration with the ambience. Typical Applications: Loudspeaker installation

RPCTW-11 COLOUR and PACKAGE Reel 100mt Colour White

CONSTRUCTION 2x0,75

Inner conductor Jacket Weight

Bare Copper Cross Section 0,75 mm2 Flexible PVC Ø=2,20x4,40 mm white 21 Kg/Km ELECTRICAL CHARACTERISTICS

Ohmic resistance max Insulation resistance Power rating

26,31 Ohm/Km >22 Mohm x Km 9A

Typical Applications: Loudspeaker installation

RPCTW-12

COLOUR and PACKAGE Reel 100mt Colour White

CONSTRUCTION 2x1,00

Inner conductor Jacket Weight

Bare/Tinned Copper Section 1,00 mm2 Flexible PVC Ø=2,80x5,60 mm white 30 Kg/Km ELECTRICAL CHARACTERISTICS

Ohmic resistance max Insulation resistance Power rating

19,52 Ohm/Km >25 Mohm x Km 11A

Typical Applications: Loudspeaker installation

RPCTW-13

COLOUR and PACKAGE Reel 100mt Colour White

CONSTRUCTION 2X1,5

Inner conductor Jacket Weight

Bare Copper Cross Section 1,50 mm2 Flexible PVC Ø=2,80x5,60 mm white 40 Kg/Km ELECTRICAL CHARACTERISTICS

Ohmic resistance max Insulation resistance Power rating

19 Mohm x Km 16,5A

www.referencelaboratory.com

p.44

#7

SPEAKER cables

RPC TP “STUDIO” series New line with a short twist pitch (TP). Typical Applications: Fixed Installation Pro Recording/TV Studio

TP

RPC40 TPS

CONSTRUCTION 2x14 AWG

Inner conductor Insulation Core arrangement Jacket Weight COLOUR and PACKAGE Reel 100mt Colour Grey

#7

Bare Copper 62x0,20 PE Ø=3,30 mm white/orange 2 twisted conductors Tube PVC Ø=8,90 Grey 91 Kg/Km

ELECTRICAL CHARACTERISTICS

Cond.Ohm resistance Insulation resistance at 20°C Twist pitch TP Temperature range

8,4 Ohm/Km >10.000 Mohm x Km 70 mm -30°C +80°C

SPEAKER cables

RPC TP “LIVE” series

New line wih a short twist pitch (TP) projected mechanically to be ideal for live. Typical Applications: Pro Live Sound Systems

REFERENCE • Speaker cable mod. RPC41 TPL

RPC41 TPL

COLOUR and PACKAGE Reel 100mt Colour Black

www.referencelaboratory.com

CONSTRUCTION 2X14 AWG

Inner conductor Insulation Core arrangement Jacket Weight

Bare Copper 62x0,20 PE Ø=3,30 mm white/orange 2 twisted conductors PVC Ø=8,90 Black 111 Kg/Km

ELECTRICAL CHARACTERISTICS

Cond.Ohm resistance Insulation resistance at 20°C Twist pitch TP Temperature range

8,4 Ohm/Km >10.000 Mohm x Km 70 mm -30°C +80°C

b La

LA R

ce en er ef R

n io at lic pp A

Montreaux

Jazz Festival

Since 1966, the Montreux Jazz Festival has been setting the standard as being possibly the most prestigious European jazz event. This year was no exception with a starstudded line-up of more than 50 artists performing at one of the ten festival venues, with renowned acts such as Joe Satriana, Al Jarreau, Lou Reed, Macy Gray and Suzanne Vega, over a quarter of a million visitors were attracted to Montreux during the 16 day event. Once again, Meyer Sound provided a wide range of it's self powered speakers PI 08 N RPLC as in previous years. Indeed, from the Miles Davis Hall and [Mark Johnson] Stravinski Auditorium to the boats and the Jazz Cafe, more than 350 loudspeaker systems were integrated into festival venues. The new QuickFly rigging system was incorporated into arrays to enable quicker load-in / load-out times. The Festival also marked the debut for the LD-2 Line Driver, a product specifically designed for integrating different types of Meyer Sound self-powered loudspeakers into an optimised full range system. As a line driver, the LD-2 can connect to cable runs of up to around 300 metres without any instability or distortion. [Mark Johnson] After a series of rigourous tests, Meyer Sound chose Reference Laboratory cables [Mark Johnson] to use at this years' edition of the Montreux Festival. Specifically, the RPLC 01 and 03 cables were chosen. Meyer's Production Manager [Mark Johnson] for the event, MarkJohnson commented "We chose the RPLC 03 in the [Mark Johnson] Stravinski and Miles Davis systems so we could [Mark Johnson] utilize our RMS (Remote Monitoring System). As the RPLC 03 has an extra signal pair, it allowed us to have the capability for power, signal and data. [Mark Johnson] The Main and Monitor systems for both these venues [Mark Johnson] were set up so all the speakers were RMS capable allowing us to closely monitor the [Mark Johnson] performance and well being of these systems on laptop computers at both FOH and monitor positions. When coupled with VEAM connectors, reconfiguring the monitor systems for different acts was both a quick and easy process. "The systems which did not use the RMS utilised the RPLC 01 cables as this does PI N 1 C0 RPL not carry an extra signal pair. [Mark Johnson] In all cases, using the Reference cables helped speed up the installation process. I 03 NP RPLC

AC/LINE cables RPLC 01 NPI 3x1,5 mm + 2xAWG 22 Ø 11,0 mm

Reprint whit the permission of Pro Sound News November 2000”

www.referencelaboratory.com

A pp lic at io n

La b

R LA R ef er en ce

Once cable jacket

with AC (power) + Balanced Signal Audio Application: powered loudspeaker • powered stage monitor • powered nearfield

Light Application: DMX and Power

Mod. RPLC-01 NPI

According with the typology of application the RPLC series cables has to be built to respect the International Standard IEC.

3x1,5 mm+2xAWG22

Ø 11 mm

Mod. RPLC-02 NPI

3x1,0 mm+2xAWG22

Ø 2x5,5 mm

Mod. RPLC-03 NPI •

• •



For Live application is build under Flame resistent CEI 20-20 IEC332.1 For Fixed installation is build under Fire Resistence (NPI not spread the fire) CEI 20-22 III IEC332.3 LSZH (Low Smoke Zero Halogen) Mod. RPLC05 ZH CEI 20-22 III IEC 332.3 CEI 2037

3x1,5 mm+2 pairs2xAWG22

Ø 12,5 mm

Mod. RPLC-06 NPI

3x2,5 mm+2xAWG22

Ø 12,2 mm

Mod. RPLC-07 NPI

3x2,50 mm+2pairs2xAWG2

Ø 13,47 mm

Mod. RPLC-08 NPI

Has chosen RPLC series for third consecutive year at Montreux jazz Festival for all powered Loudspeaker and Stage Monitor.

3x2,0 mm+2 pairs2xAWG22

Ø 13,4 mm

Mod. RPLC-09 NPI

3x1,5 mm+2xAWG22

Ø 13,9 mm

Mod. RPLC-11

3x2,0 mm+2xAWG22

Ø 15,9 mm

Mod. RPLC-12

3x1.5mm +2 pairs 2xAWG22

Ø 14 mm

To optimize the installation’s time schedule To support and mantein the original audio performance. www.referencelaboratory.com

p.47

COMPOSITE cables

AC/LINE series #10

A single Cable Jacket With AC (power) + 110 Ohm Balanced Line RPLC Series provide a unique single-cable solution for powered loudspeaker systems. Effective insulation and construction quality preserves audio signal integrity while allowing compact, mechanically reliable and fast installations. The use of NPI* and LSZH* materials makes RPLC cables the right choice for both permanent and mobile installations. Besides for live application it’s super flexible PVC compound , in order to have the faster memory cable. Typical Applications: Powered loudspeaker and stage monitoring systems, Live and studio nearfield monitoring systems, Permanent installations Light Controls (DMX data + POWER) NPI PVC: complying to IEC 332/1 (flame inhibiting material)

ELECTRICAL & PHYSICAL MODEL

AC power section

Balanced Line section O.D./ Screen Shield Nom. CONSTRUCTION Insul.mat./ Impedance type D.C.R. NUMBER OF jacket mat. BALANCED LINES/POWER LINES [Ω/m] [Ω] [mm]

RPLC01 NPI RPLC01

1 / 3x1.5 mmq

RPLC02 NPI

1 / 3x1.0 mmq TWIN

RPLC03 NPI RPLC03

2 / 3x1.5 mmq

RPLC04 NPI

2 / 3x1.5 mmq TWIN

A1/My 0,018 +tinned copper braid

110

4,50/ PE/ superflex PVC

Max. AWG # Insulation AWG # Cond. jacket Temp. O.D. / oper. / Area resist / Area insulation material range Weight Voltage [kV]

1

[mm2]

[MΩ/ Km]

AWG22/ >100 0,34

[mm2] AWG 16/ 1,50 AWG 17/ 1,00 AWG 16/ 1,50 AGW 16/ 1,50 AWG 13/ 2,50

RPLC06 NPI RPLC06

1 / 3x2.5 mmq

RPLC07 NPI RPLC07

2 / 3x2.5 mmq

AWG 13/ 2,50

RPLC08 NPI RPLC08

2 / 3x2.0 mmq

AWG 14/ 2,00

RPLC09

1 / 3x1.5 mmq

RPLC10

1 / 3x2.5 mmq

RPLC11

1 / 3x2.0mmq

RPLC12

2 / 3x1.5 mmq

0,018

110

0,018

110

0,018

110

0,056

110

PE/ superflex PVC PE/ superflex PVC

1

PE/ superflex PVC

1

PE/ superflex PVC

Overall

1

1

AWG22/ >100 0,34

[mm]/ [Kg/Km] PVC TNT -20/+70 10,7/164 tape + NPI PVC PVC NPI PVC -20/+70 2x6/120 [°C]

PVC

TNT -20/+70 12,4/200 tape + NPI PVC PVC NPI PVC -20/+70 8,4+4,9/ 202 PVC

TNT tape + superflex PVC PVC TNT tape + superflex PVC PVC TNT tape + superflex PVC PVC 13,9/ PVC

AWG 16/ 1,50 AWG22/ >100 AWG PVC+ 15,00/ 0,34 13/ overal TNT 2,50 1 PVC tape+ jacket superflex PVC AWG22/ >100 AWG PVC+ 15,00/ 1/0,34 147 overal TNT 2.00 1 PVC tape + jacket superflex PVC PVC+ 15,00/ AWG >100 AWG overal TNT 1x0,34 16/1,5 1 PVC tape + jacket superflex PVC

-30/+70 11,8/195

-30/+70 13,9/231

-30/+70 13,6/221

-20/+70 13,7/222

-30/+70 15/254

-30/+70

-30/+70

www.referencelaboratory.com

p.48

MULTIMEDIA CONTROL cables #9

RPLC19-NPI

Development for speaker MM4xP Meyer Sound

Composite cable with power 2x1mmq plus balanced audio cable Application: Power + signal for active loudspeakers with CC. power supply

POWER SECTION

AUDIO SECTION

2x1 mmq AWG17 tinned copper Insulation PVC Red and Black Max. op Voltage 100 volt Outer jacket PVC NPI CEI 20-22 dia 6.5 grey colour

Balanced 2x035 AWG 22 Drain wire 025-AWG24 Shield FOIL Insulation PE

RPLC10NPI Composite cable with power 2x1.5mmq plus balanced audio cable Application: Power + signal for active loudspeakers with CC. power supply

POWER SECTION

AUDIO SECTION

2x1.5 mmq AWG16 tinned copper Insulation PVC Red and Black Max. op Voltage 100 volt Outer jacket PVC NPI CEI 20-22 Dia 8.3 black colour

Balanced 2x035 AWG 22 Drain wire 025-AWG24 Shield FOIL Insulation PE

SECURITY CONTROL cables #9

REFERENCE • RCSR01

RCSR 01 Composite cable video 50 ohm + Power

POWER SECTION

AUDIO SECTION

2x0.5 mmq AWG20 Red copper Insulation PVC Red and Black HT 105 Max. op Voltage 1200 volt Outer jacket PVC O.D.6.5 White colour

0,50 AWG 20 Polyethylene Shield braid red copper Impedance 50 OHM

REFERENCE • RCSR02

RCSR 02 Composite cable video 75 ohm + Power

POWER SECTION 2x1.5 mmq AWG16 Red copper Insulation PVC Red and Black HT 105 Max. op Voltage 3000 volt Outer jacket PVC O.D.8.2 NPI CEI 20-22 Grey colour www.referencelaboratory.com

AUDIO SECTION 0,41 AWG 20 Foma PE Shield braid red copper + FOIL Impedance 75 OHM

p.49

FIRE ALARM cables

AC/LINE series #12

Fire alarm Reference cables is a new family designed for use in critical circuits that necessitate the cable's electrical operation in condiction of exposure to fire and water. Reference fire alarm cables wil provide the cable operation required for emergy power to fire pump and power panel for lighting and all other power function that may support safe and rapid building evacuation. Application: Fire protection- Emergy power - Home security - Comunication Smoke detector

RFA-2.0 Conductor Jacket Rated temp. Insulation Operation Approval

NO PLENUM

PLENUM

Solid bare copper PVC w/sun resistance ripcord and sequential footage 60°C Foam Polypropilene 300 Volt UL Type FPLR-NEC article 760 CUL Type CMP/FT4 - Cal. Marshal

Solid bare copper Low smoke PVC ripcord and sequential footage 75°C Low smoke PVC 300 Volt UL Type FPLR-NEC article 760 CUL Type CMP/FT7 - Cal. Marshal

RFA - 1.3 Construction Color code Insulation Capacitance Impedance Resistance Vel. of Propag. Jacket

2 conductors AWG 16 solid bare copper black - red 010 inch nominal = 32,5 pF/ft 57 Ohm 4,016 Ohm/Feet 55% red

RFA - 2.0 2 conductors AWG 14 solid bare copper black - red 012 inch nominal = 32,3 pF/ft 56 Ohm 2,525 Ohm/Feet 55% red

Available also in FOIL SHIELD VERSION code: RFA 1.3 - SH and RFA - 2.0 - SH

RFA - 1.0 Construction Color code Insulation Shield Normative References Vel. of Propag. Jacket (extruded)

2 conductors AWG 17 solid bare copper blue - brown LSZH Foil IEC6033.2 (lszh) IEC754-1 754-2 halogen free 55% LSZH red

RFA - 1.5 2 conductors AWG 15 solid bare copper blue- brown LSZH Foil IEC6033.2(lszh) IEC754-1 754-2 halogen free 55% LSZH red

www.referencelaboratory.com

p.50

DMX cables

RDMX series #9

The RDMX Series is designed to provide compact and high quality cables for lights control. Superior power transfer figures are possible since all cables feature a 120 ohm characteristic impedance providing better impedance matching properties. RDMX 01 Two conductors designed to transfer the signal for the digital light technology and observing the standard reference UL2919,manteining also a reasonable flexibility. Typical Applications: Light and scanner. Available colours: black.

RDMX 01

ELECTRICAL & PHYSICAL Capacitance Nom. Impedance Insulation material Screen type Drain wire AWG # / Area Qty x [mm]. O.D. / Overall jacket insulation material Working temp. range Weight

[pF/m] [Ω]

[mm2] [mm] [°C] [Kg/Km]

42 120 PE Al/My foil (Al outside)+ 90% braid (between shields) 0.22 [mm2], (7 x 0.20) tinned copper AWG 24 / 2 x 0.22 2 x (7 x 0.20) tinned copper 6,30 / PVC -20 / +70 49,85

RDMX 01 SF

ELECTRICAL & PHYSICAL Capacitance Inductance Cond. D.C.R. Screen type Shield D.C.R. Nom. Impedance Insulation material Test voltage AWG # / Area [mm2] Insulation resistance

47 [pF/m] < 0,6 mH/Km 0.087 [Ω/m] Braided (tinned copper, >90%) + drain wire 0.016 [Ω/m] 120 [Ω] PVC 1000 [V] AWG 24 / 0.22 red copper > 100 MΩ/Km

O.D. / Overall jacket insulation material Working temp. range Available colours: Blue, Grey, Black

5,9 [mm] / SuperFlex PVC -20 / +70 [°C]

www.referencelaboratory.com

p.51

DMX 120 Ohm cables

DMX series #9

Innovative construction with polyurethane & kevlar. Typical Applications: PRO-LIVE in critical conditions (high temperature weather, mechanical and logistic)

RDMX01 PUR

COLOUR and PACKAGE Reel 100mt Colour Black

Colour

CONSTRUCTION 2x0,34 KEVLAR + PUR Inner conductor Insulation Core arrang. Shield 1 Shield 2 Jacket

Extra Fine wires tinned copper 2x0,34 IEC228 CL5 Foam PE Black/natural Ø=1,45 mm 2 twisted conductors with Kevlar fill Aluminium/my tape, coverage 100% Tinned copper braid Black PUR Ø=6,00 mm

ELECTRICAL CHARACTERISTICS Cond.Ohm resistance Shield Ohm resistance Insulation resistance Inductance Impedance Density Capacitance cond./cond. Capacitance cond./shield Test voltage Tensile strenght

100 MΩ/Km

O.D. / Overall jacket Working temp. range Weight

12,70 [mm] / SuperFlex PVC -20 / +70 [°C] 12,5 [Kg/100Mt]

15 [mm] / SuperFlex PVC -20 / +70 [°C] 25 [Kg/100Mt]

Minimum bending radius 15X OD

www.referencelaboratory.com

p.53

LIGHT cables

RLC series #9

RLC is a range of multiconductor cable for the lighting applications on stage. Its design has been projected to maintain the smaller diameter and the best flexibility in order to resolve the difficult of the live applications. It is manufactured with the conformity CE 73/23 and IEC regulation. Typical applications: Live and Installation lighting.

CONSTRUCTION / MECHANICAL MODEL AWG# / Area Cond. D.C.R. Capacitance [mm ]*

Ω/Km] [Ω

[pF/m]

Jacket material

7 x 1,5 (AWG15) 12 x 1,5 (AWG15) 19 x 1,5 (AWG15) 7 x 2,5 (AWG13) 12 x 2,5 (AWG13) 19 x 2,5 (AWG13)

140 -30/+70

Size [mm]

Weight [Kg/Km]

9,7 12,4 14,4 11 14,7 17,4

277 406 322 252 416 632

SUPER FLEXIBLE and LSZH

series #9

Description: Any LIGHT-nex cable is highly flexible and nice to handle; the special compound studied for the outer jacket is also opaque and velvety. These cables are ideal for both heavy duty daily usage or contractor applications for at least reasons. FLAME RETARDANT MATERIALS (NPI) All models are CEI 20-22 II compliant (flame retardant property), and feature materials with minimal toxic gas emissions – a must for public spaces installations. GOOD HANDLING Thanks to the special compound used for the outer jacket these cables are extremely flexible and yet resistant to rubbing and scraping; the perfect solution for any task that involve frequent handling or incidental stamping (i.e. LIVE). The material is also highly resistant to mineral oils, and suited to work within a wide temperature range (–30°C a +80°C). LOW SMOKE ZERO HALOGEN - TINNED COPPER CABLES Single core cables with flexible tinned copper conductor, under double insulation: insulated with special M1 thermoplastic compound, under an external special M1 thermoplastic sheat (classified as M1 in accordance with Italian CEI 20-11). Flame and fire retardant cable, with very low smoke and fume emission and without halogenidric gas emission; therefore those cables are recommended for installations which need maximum safety in case of fire: emergency lights, aeration systems, emergency telephone systems and emergency audio/voice evacuation systems. flame retardant material NPI. Comparation Chart Jacket Working Temperature Min. (°C) Working Temperature Max. (°C) Short circuit temperature (°C) Flame propagation Fire resistance (NPI) Low Smoke Zero Halogen Stress and abrasion resistance Ozone resistance Resistance to oil and grease Water resistance

H07RN-F PIREFLEX Neoprene -35 60 200 CEI 20-35 No No AG4/Very good Yes Yes Yes

H07RN-F TITANEX 11 REFERENCE Light nex Neoprene PVC Compaund -35 -30 85 90 250 200 CEI 20-35 CEI 20-35 No CEI 20-22 No CEI 20-37 Very good Good Yes Yes Yes Yes Yes

LIGHT nex series is conform to: • CEI 20-35 • CEI 20-22 II • CEI 20-37 • 2002/95/CE (RoHS) www.referencelaboratory.com

p.54

LIGHT-nex cables

RLC-M-SF series

SUPER FLEXIBLE

#9

Typical Applications: light, on the road - AC cables - Discharge Lights

Recommended by

SUPER FLEXIBLE JACKET WITH TINNED COPPER CABLES Single core cables with flexible tinned copper conductor, under double insulation: insulated with special M1 thermoplastic compound, under an external special M1 thermoplastic sheat (classified as M1 in accordance with Italian CEI 20-22). Flame and fire retardant material NPI.

and

MODEL RLC-M 01 SF RLC-M 02 SF RLC-M 03 SF RLC-M 04 SF RLC-M 05 SF RLC-M 06 SF

N° OF CONDUCTOR 1 1 1 1 1 1

AREA mm2 25 35 50 70 95 120

AWG 3 2 1 1/0 4/0 4/0

LIGHTING

YASUKA CORPORATION

OVERALL DIAMETER 14,3 15,5 18,4 20,2 24,0 26,0

Multicore cables with flexible tinned copper conductor,insulated with special M1 thermoplastic compound, under an external special M1 thermoplastic sheat (classified as M1 inaccordance with Italian CEI 20-22).

MODEL RLC-M 07 SF RLC-M 08 SF RLC-M 09 SF RLC-M 10 SF RLC-M 11 SF RLC-M 12 SF RLC-M 13 SF RLC-M 14 SF RLC-M 15 SF RLC-M 16 SF RLC-M 20 SF RLC-M 21 SF RLC-M 23 SF RLC-M 24 SF RLC-M 25 SF RLC-M 26 SF RLC-M 27 SF RLC-M 28 SF RL-nex 19x4

N° OF CONDUCTOR 3 3 3 10 5 19 19 2 2 2 7 3 5 3 3 25 3+4 3+3 19

AREA mm2 1,5 2,5 4 2,5 6 1,5 2,5 1,5 2,5 4 4 6 10 10 25 2,5 10+0,5 10+1,5 4

AWG 15 13 11 13 9 15 13 15 13 11 11 9 7 7 3 13 7+30 7+15 11

OVERALL DIAMETER 8,5 10,2 12,0 17,0 16,9 16,9 20 8,0 9,9 11 18,0 14,0 21,2 18 25,5 25,5 16 19 26

Typical Applications: Light/Live 19 new additional models, “conductors and size as ZH” i.e. RLC-M08-SF=3X2,5

RLC-M 08 SF i.e. CONSTRUCTION 3X2,5 mm

Conductor (nxmm) External diameter (mm) Conductor diameter (mm) Insulation thickness (mm) Jacket thickness (mm) Nominal voltage (V)

48x0,25 tinned 10,0 +0,2 3,45 +0,1 0,75 1,0 300/500 V

ELECTRICAL CHARACTERISTIC

Electric resistance (Ohm/Km) Self extinguishing grade Ultimate % elongation Ultimate tensile stress unitary (Kg/mm2) After aging characteristics Temperature range (°C)

The specifications for the RLC-M-SF are available under requirement www.referencelaboratory.com

7,40 positive (CEI normative) 220 1,45 without important variations 30/80

p.55

LIGHT-nex cables

RLC-M-ZH series

NPI LSZH

#9

Typical Applications: light - fixed installations - Discharge Lights.

MODEL RLC-M 01 ZH RLC-M 02 ZH RLC-M 03 ZH RLC-M 04 ZH RLC-M 05 ZH RLC-M 06 ZH

N° OF CONDUCTOR 1 1 1 1 1 1

AREA mm2 25 35 50 70 95 120

AWG 3 2 1 1/0 4/0 4/0

OVERALL DIAMETER 14,3 15,5 18,4 20,2 24,0 26,0

Multicore cables with flexible tinned copper conductor,insulated with special M1 thermoplastic compound, under an external special M1 thermoplastic sheat (classified as M1 in accordance with Italian CEI 20-11). Flame and fire retardant cable, with very low smoke and fume emission and without halogenidric gas emission; therefore those cables are recommended for installations which need maximum safety in case of fire: emergency lights, aeration systems, emergency telephone systems and emergency audio/voice evacuation systems.

MODEL N° OF CONDUCTOR RLC-M 07 ZH 3 RLC-M 08 ZH 3 RLC-M 09 ZH 3 RLC-M 10 ZH 10 RLC-M 11 ZH 5 RLC-M 12 ZH 19 RLC-M 13 ZH 19 RLC-M 14 ZH (450-759V) 2 RLC-M 15 ZH (0.6-1kV) 2 RLC-M 16 ZH (450-750V) 2 RLC-M 17 ZH (0.6-1kV) 2 RLC-M 18 ZH (450/750V) 2 RLC-M 19 ZH (0.6-1kV) 2 RLC-M 20 ZH 7

AREA mm2 1,5 2,5 4 2,5 6 1,5 2,5 1,5 1,5 2,5 2,5 4 4 4

AWG 15 13 11 13 9 15 13 15 15 13 13 11 11 11

OVERALL DIAMETER 8,5 10,2 12,0 17,0 16,9 16,9 20 8,0 9,9 9,6 11,0 11,0 11,8 18

RLC-M 09 SF i.e. CONSTRUCTION 3X2,5 mm

Conductor (nxmm) External diameter (mm) Conductor diameter (mm) Insulation thickness (mm) Jacket thickness (mm) Nominal voltage (V)

48x0,25 tinned 10,0 +0,2 3,45 +0,1 0,75 1,0 300/500 V

ELECTRICAL CHARACTERISTIC

Electric resistance (Ohm/Km) Self extinguishing grade Ultimate % elongation Ultimate tensile stress unitary (Kg/mm2) After aging characteristics Temperature range (°C)

7,40 positive (CEI normative) 220 1,45 without important variations 30/80

www.referencelaboratory.com

p.56

VIDEO cables

RVC series

COAXIAL

#11

The RVC coaxial cables feature a high density double braided copper shield. They are the best choice where minimum attenuation is required. RVC01 is equivalent to standard RG59/H and can be substituted with confidence for any application. Typical applications: SPDIF connections, Video connections, Ethernet, PC-network connections.

REFERENCE • RVC 01 RVC-01

RVC-02

SPECIFICATIONS Inner conductor (core) Core insulation Screen type

RVC01 (RG59 B/U)

RVC02(RG58 C/U)

[mm]

0,60 (solid / red copper) 0,50 (19x0,18 / tinned) PE PE Double braided >95% [red Braided (tinned) + red copper(1st screen) + tinned copper(2nd screen)] Capacitance (pF/m) 66 97 Outer jacket PVC PVC Nom. D.C.R. (Ω/m) 90%) 17 [Ω/m] 55 [pF/m] 75 [Ω] 80% 4,5 [mm] / PVC -30 / +80 [°C] 45 [Kg/Km]

Video cables

RVC series

TRIAXIAL

#11

Triaxial cables are used for connections between videocameras and related equipment. Triaxial cables feature two insulated shields for superior noise rejection ratios and either a solid or stranded center conductor. Typical applications: connections for: camera DC power, intercom to operator, teleprompter feeds, monitoring feeds and even automatic or robotic functions.

REFERENCE • RVC 03

CONSTRUCTION and ORDERING Codes Suffix RVC

Reel 100 m

Colours Red

SPECIFICATIONS Inner conductor (core) Core insulation Shield Primary jacket 2nd shield Jacket Overall diameter Working temp Characteristic impedance Capacitance Propagation velocity ATTENUATION 5 MHz 10 MHz 50 MHz 100 MHz

[mm]

[mm] [°C] [Ω] [pF/m] [m/s]

[dB/100m:]

RVC03

RVC04

RVC05

1,00 / silver copper PE silver copper braid PE Red copper braid PVC 8,50 -30 / +70 75 56 80%

1,40 / silver copper PE silver copper braid PE Red copper braid PVC 11,00 -30 / +70 75 56 80%

2,16 / silver copper PE Silver copper braid PE Red copper braid PVC 14,00 -30 / +70 75 56 80%

1,80 2,10 5,95 9,00

1,13 1,60 3,58 5,20

0,80 1,10 2,60 3,90 www.referencelaboratory.com

p.60

SUPER VHS cables

RS-VHS series #11

RS-VHS is a dedicated cable to well connected the Super VHS equipment .It is a coaxial with two line in order to supply the transmission of the chrominance and luminance. For its flexibility has been adopted a flexible PVC especially for the live applications where it is required.

SPECIFICATIONS Inner conductors Insulation Screen type Single cond. jacket Capacitance Outer jacket Nom. D.C.R. Shield D.C.R. Nom. Impedance Propagation velocity Overall diameter Working temp Weight

[mm]

RS-VHS

Tinned copper PE foam Tinned copper braid PVC (white/yellow) 56 PVC (+ cotton fillers and TNT tape) 62 30 75 80% 6,70 -30 / +80 39

(pF/m) (Ω/km) (Ω/km) [Ω] [mm] [°C] [Kg]

CONSTRUCTION and ORDERING Codes Suffix RS-VHS

Reel 100m

Colours BK (Black)

Minimum bending radius 15X OD

MULTI VIDEO COAX RGB cables

RRGBseries #11

The RRGB multicore 75 ohm coaxial cables feature a high density double braided copper shield. They are the best choice where minimum attenuation and space saving is a must. For its flexibility has been adopted a flexible PVC especially for the live applications where it is required. Typical applications: RGB connections, high definition video.

CONSTRUCTION and ORDERING Codes Suffix RRGB

Reel 100 m

SPECIFICATIONS Inner conductor # Core insulation Screen type Capacitance Single cond. jacket Nom. D.C.R. Shield D.C.R. Nom. Impedance Propagation velocity Outer jacket /O.D. Weight Working temp

[pF/m] [Ω/km] [Ω/km] [Ω] [mm] [Kg/Km] [°C]

Minimum bending radius 15X OD www.referencelaboratory.com

Colours black

RRGB03

RRGB05

RRGB06

3, tinned copper PE foam Tinned copper braid 57 PVC 62 30 75 80% PVC / 10,00 13,5 -30 / +80

5, tinned copper PE foam Tinned copper braid 57 PVC 62 30 75 80% PVC / 11,00 16,5 -30 / +80

6, tinned copper PE foam Tinned copper braid 57 PVC 62 30 75 80% PVC / 11,00 22 -30 / +80

p.61

MULTI VIDEO COAX RGB cables

RRGB/AC series #11

The RRGB/AC multicore 75 ohm coaxial cables plus Power in a unique jacket. They are the best choice for installation and live application For its flexibility has been adopted a flexible PVC especially for the live applications where it is required. Typical applications: RGB connections in studio, broadcast OB van.

CONSTRUCTION and ORDERING Codes Suffix RRGB 05/AC RRGB 06/AC

Reel 100 m 100 m

SPECIFICATIONS Inner conductor # Screen type Capacitance Single cond. jacket Nom. D.C.R. Shield D.C.R. Nom. Impedance Propagation velocity Outer jacket /O.D. Weight Working temp

[pF/m] [Ω/km] [Ω/km] [Ω] [mm] [Kg/Km] [°C]

Colours black black

VIDEO

VIDEO

5, tinned copper Tinned copper braid 57 PVC 62 30 75 80% PVC / 13,00 13,8 -30 / +80

6, tinned copper Tinned copper braid 57 PVC 62 30 75 80% PVC / 16,00 16,8 -30 / +80

POWER AC 3x1.0 MMQ

Minimum bending radius 15X OD

MULTI VIDEO COAX RGB cables

RAVAC series #11

Typical Applications: audio/video conference installations

VIDEO CONSTRUCTION 3x2x0,14

3xVIDEO AC 2x4,00 1 2

filler

Inner conductor Insulation Shield Jacket

AC 2x4,00 mm CONSTRUCTION

RAVAC 01

Inner conductor Insulation Jacket COLOUR and PACKAGE Reel 100mt Colour Black

Tinned copper Foam Polyethylene Tinned Copper Braid, coverage>95% Black PVC Ø=2,60 mm

Bare Copper Cross Section 4,00 mm PVC Blue/red Black PVC Ø=11,00 mm

MICROPHONE 3x (2x0,14) CONSTRUCTION

Inner conductor Insulation Shield Twisting Jacket

Bare Copper Cross, Class5 XLPE Aluminium Tape+Drain Wire AC 2x4,00 in center, 3RGB+3x(2x0,14) around with fillers Black PVC Ø=2,80 mm OVERALL

1 - Tape 2 - Jacket

Non wovens Black PVC Ø=22,0 mm

Minimum bending radius 15X OD www.referencelaboratory.com

p.62

COMPOSITE cables

RCC series #11

RCC reporter series has been designed as a single high quality connection cable for all the signals of an integrated audio-video transmission. Typical applications: Reporter set up from OB van to sport stadium, indoor, outdoor.

OVERALL – RCC01 Composition Overall screen Jacket / color O.D. Weight

(1) AC power 3x1,50 - (2) 6 Audio pairs AWG24 - (3) 8 general purpose AWG24 - (4) 4 Video coaxial Braided cotton + overall >86% braided tinned copper PVC / Red 16 [mm] 428 [kg/km]

(1) – AC POWER CABLE AWG# / Area [mm2] Insulation /colors Overall insulation Cond. D.C.R. [Ω/Km] Insulation resistance [MΩ/Km] Working voltage [V] Test voltage [kV]

AWG16 / 1,50 (red copper) PVC / Blue-Brown-Black Cotton tape over the 3 conductors+ double braided tinned copper screen + overall cotton tape 100 300/500 2

AWG# / Area [mm2] Screen Cond. D.C.R. [Ω/Km] Insulation resistance [MΩ/Km] Capacitance cond/cond [pF/m] Capacitance cond/screen [pF/m] Insulation Pair jacket / colour Pair colours

AWG24 / 0,22 (red copper) 100% Lap, tinned copper 100 60 110 XLPE PVC / Black (white-blue) (white-red) (white-yellow) (white-green) (white-black) (white-grey)

(2) – AUDIO BALANCED LINES

(3) – UNBALANCED AUDIO / GENERAL PURPOSE AWG# / Area [mm2] Cond. D.C.R. [Ω/Km] Insulation resistance [MΩ/Km] Jacket / colours

AWG24 / 0,22 (red copper) 100 PVC / white, blue, red, yellow, green, grey, pink, brown

(4) – COAXIAL VIDEO Core Core insulation Insulation resistance [MΩ/Km] Screen Cond. D.C.R. [Ω/Km] Impedance [Ω] Capacitance cond/screen [pF/m] Jacket / colours Minimum bending radius 18X OD

www.referencelaboratory.com

Tinned copper PE foam >10000 >95% tinned copper braid 62 75 57 PVC / Black, Yellow, Red, Blue

p.63

VIDEO COMPOSITE cables

RVC series #11

It is a line designed to optimise in once overall jacket the coaxial (2=RVC-59D or 4=RVC-59F) 75 Ohm plus two balanced cable (intercom or any analogue additional ch) in order to meet the new generation of live digital console. Typical Applications: to meet the digital live console for transmission data because in once jacket the mechanical performances is much better and faster for live applications

Suffix

Reel

Colour

RVC-59F

100mt

Black

ORDERING Codes

Inner conductor Insulation Shield Coax Jacket

Bare Copper Ø 0,75 mm Foam Polyethylene Ø 3,70 mm Aluminium tape+Tinned copper braid PVC white Ø 5,80 mm

AUDIO PAIRS CONSTRUCTION

RVC-59F

Inner conductor Insulation Drain wire Shield Pair Jacket

Reel

Colour

100mt

Black

ELECTRICAL CHARACTERISTICS

CONSTRUCTION

RVC-59D

Suffix RVC-59D

ORDERING Codes

Flexible Bare Copper 28x0,10 XLPE Tinned Copper Spiral shield tinned copper PVC Ø 2,80 mm

Electrical resistance at 20°C Capacity Velocity Ratio Attenuation at 800MHz. Temperature for fixed use Temperature for movable use Behaviour with fire

43 Ohm/Km. 54 pF/mt. 80% 24 dB/100mt. -30 +70°C -10+70°C Norm: IEC Cat: 332.1

OVERALL Total jacket Weight

PVC black Ø 15,00 mm 412 Kg/Km

Minimum bending radius 15X OD

VIDEO & ETHERNET COMPOSITE cables

RVC series #11

It is a line designed to optimise in once overall jacket the coaxial (2 or 4) 75Ohm plus two balanced cable (intercom or any analogue additional ch)in order to meet the new generation of live digital console plus Ethernet cable very important for a circuit (network)with more digital console. Typical Applications: to meet the digital live console for transmission data because in once jacket the mechanical performances is much better and faster for live applications. COLOUR and PACKAGE Reel 100mt Colour Black

RVC-59D/Eth

ETHERNET CONSTRUCTION Inner conductor Insulation Twisting Shield Coax Jacket

VIDEO CONSTRUCTION

AUDIO PAIRS CONSTRUCTION Inner conductor Insulation Drain wire Shield Pair Jacket

Flexible Bare Copper wire 28x0,10 XLPE Tinned Copper Spiral shield tinned copper PVC Ø 2,80 mm

Flexible Bare Copper Wire Polyethylene 2 cores to the pair Aluminium tape+Tinned copper braid PVC Ø 6,20 mm

Inner conductor Insulation Shield Coax Jacket

Bare Copper Ø=0,75 mm Foam polyethylene Ø=3,70 mm Aluminium tape+Tinned copper braid PVC Ø 5,80 mm

Total jacket Weight

PVC black Ø 18,00 mm 322 Kg/Km

OVERALL

Minimum bending radius 15X OD

www.referencelaboratory.com

p.64

RGB/AC/C series

COMPOSITE MULTI VIDEO cables

Coax RGBHV + AC 3x1,00 + 5xAWG24

#11

Typical Applications: Live, conference room/video projector COLOUR and PACKAGE Reel 100mt Colour Black

CONTROL = 5x0,14

Inner conductor

RGB05/AC-C

VIDEO CONSTRUCTION Tinned copper

Insulation

Foam Polyethylene

Shield

Tinned Copper Braid Coverage>95%

Jacket

PVC Ø=2,60 mm red/green/black/blue/white

Conductor Jacket

CONTROL 5x 022 - AWG24 PVC

Filler Tape Overall Jacket

OVERALL Polypropilene Non wovens PVC Ø=15,00 mm

APPLICATION video projector

(a) RGB05 composite cable

Minimum bending radius 15X OD PC or DVD (b) Stage box

MULTI VIDEO COAX cables

RCMA/VR series

2XMINIVIDEO +1X SDI +3X MICROPHONE

#11

Typical Applications: audio/video conference installations.

REFERENCE • RCMA/VR02 2XMINIVIDEO + 1XSDI + 4X MICROPHONE

Inner conductor

VIDEO CONSTRUCTION Tinned copper

Insulation

Foam Polyethylene

Shield

Tinned Copper Braid Coverage>95%

Jacket

PVC Ø=2,60 mm

MICROPHONE CONSTRUCTION 3X2X0,14 MM Inner conductor Plain Bare Copper

RCMA/VR02

Insulation

XLPE

Shield

Al/My tape drain wire

Jacket

PVC Ø=3,20 mm black whit white numbers

TWISTING Tape

Cotton tape

Total Jacket

red wine PVC Ø=16 mm

Approx. Weight

247 Kg/Km

1XSDI CONSTRUCTION Inner conductor Plain Bare Copper Insulation

Foam PE Ø=4,50 mm

Shield

Al/My/Al tape

Shield

Tinned Copper Braid

Jacket

Black PVC Ø=6,00 mm

Minimum bending radius 15X OD www.referencelaboratory.com

p.65

COMPOSITE cables MICROPHONE

RCMAV series

Stereo/Coaxial/S-VHS/AC

#11

Versatile composite cables. An extremely compact cable featuring ideal for installation when the space is very limited. Typical Applications: Audio/Video S-VHS Complying to: IEC 228 (red copper), CE 120-35/IEC 332.1 (flame propagation)

RCMAV01

SPECIFICATIONS

CONSTRUCTION and ORDERING Codes Construction

Reel

Colours

2 balanced audio + 1 video 75 Ohm

100 m

Bk (black)

Screen type Insulation material AWG # / Area [mm2] O.D. / Jacket Inner conductors Insulation Screen type Propagation velocity O.D. / Jacket material O.D. / Jacket material Working temp. range

Braided (tinned copper, > 90%) or Lap (tinned copper) XLPE + Overall TNT tape AWG 26 / 0,14 (red copper) 3,20 [mm] / PVC Tinned PE foam Tinned copper braid (>95%) 80% 2,60 [mm] / PVC 11,00 [mm] / overall TNT tape + PVC -30 / +80 [°C]

micro coax 75 Ohm section

RCMAV02 COLOUR and PACKAGE Reel 100mt Colour Black

MICROPHONE CONSTRUCTION 3X(2X0,14)mm Inner conductor Insulation Tape Shield Jacket Capacitance cond./cond. Capacitance cond./shield Impedance

Bare Copper Cross Section 0,14mm2 XLPE Non wovens Tinned copper Coverage >90% PVC black Ø 3,20mm 52 pF/m 89 pF/m 95 Ohm

TWISTING MICROPHONE 3X2X0,14 + VHS WITH FILTER Tape Total jacket Weight

Non wovens PVC black Ø 12,40mm 136 Kg/Km

2 VHS CONSTRUCTION Inner conductor Insulation Shield Jacket Capacitance Impedance

MULTI VIDEO COAX cables

Tinned Copper Foam Polyethylene Tinned copper Braid Coverage>95% PVC Ø 2,60mm 56 pF/m 75 Ohm

RCMA/VR series #11

Typical Applications: audio/video conference installations.

2XMINIVIDEO +1X SDI +4X MICROPHONE + AC 3x2.5

RCMA/VR03-AC VIDEO CONSTRUCTION Inner conductor Tinned copper Insulation

Foam Polyethylene

Shield

Tinned Copper Braid Coverage>95%

Jacket

PVC Ø=2,60 mm

TWISTING

AC CONSTRUCTION

Tape

Cotton tape

Total Jacket

Blue PVC Ø=16 mm

Approx. Weight

247 Kg/Km

3x 2.5 Colour Blue - Brown -Yel/Gr

1XSDI CONSTRUCTION Inner conductor Plain Bare Copper

MICROPHONE CONSTRUCTION 4X2X0,14 MM Inner conductor Plain Bare Copper

Insulation

Foam PE Ø=4,50 mm

Insulation

XLPE

Shield

Al/My/Al tape

Shield

Al/My tape drain wire

Shield

Tinned Copper Braid

Jacket

PVC Ø=3,20 mm

Jacket

Black PVC Ø=6,00 mm

black whit white numbers www.referencelaboratory.com

p.66

COMPOSITE cables

RCBM series

MICROPHONE STEREO/COAXIAL/S-VHS/AC

#11

A versatile composite cable. An extremely compact cable featuring two VHS lines, a low profile high quality microphone channel, and a shielded AC power connection. The overall TNT tape it’s the lightweight solution that provides extra mechanical reliability over time. Typical applications: Broadcast mobile to connect with cameras. Complying to: IEC 228 red copper CEI 20-35 / IEC 332.1 flame propagation

RCBM01

CONSTRUCTION and ORDERING Codes Construction 1 balanced audio+2 video 75Ohm+Power 3x075

Reel 100 m

Colours Bk (black)

SPECIFICATIONS Capacitance Nom. Impedance Screen type Insulation material AWG # / Area [mm2] O.D. / Jacket

52 [pF/m] 95 [Ohm] Braid (tinned copper, >90%) XLPE + Overall TNT tape AWG 26 / 0.14 (red copper) 3,20 [mm] / black PVC

Microphone section

Inner conductors Insulation Screen type O.D. / Jacket

Tinned copper PE foam Tinned copper braid (>95%) 2.60 [mm] / PVC

VHF Section

Inner conductors Insulation Screen type O.D. / Jacket

Bare copper, 0.75mm2 (AWG18) PVC (blue/brown/yellow-green) Tinned copper braid (>95%) 6.00 [mm] / Black PVC with cotton fillers

AC Line Section

O.D. / Jacket Working temp. range Weight

13,00 [mm] / overall TNT tape + black PVC -30 / +80 [°C] 280 [Kg/Km]

RHT series

COMPOSITE MICRO CIRCULAR cables

Home Theather

#11

Typical Applications: home theater

(6 speaker)

(2 audio microphone) (5 video RGBHV)

SPEAKER CONSTRUCTION

RHT 625

Conductor

Tinned Copper Cross Section 1,00mm2

MICROPHONE CONSTRUCTION COLOUR and PACKAGE Reel 100mt

Inner conductor Insulation Drain Wire Shield

VIDEO CONSTRUCTION

Colour Black

Bare Copper Ø= 18x0,10mm Polyolephyne Ø= 1,00mm Tinned copper Aluminium tape

Inner conductor Insulation Shield

www.referencelaboratory.com

Tinned Copper Foam Polyethylene Tinned Copper Braid

Coverage >95%

p.67

OBVAN COMPOSITE cables

ROB-C series

SUPER FLEXIBLE

#11

Typical Applications: Ob-Van wiring, audio/video room wiring, local studio control.

2x0,22 3xVHS

ROB-C 01 COLOUR and PACKAGE Reel 100mt Colour

3xVHS CONSTRUCTION Inner conductor Insulation Shield Jacket

TOTAL TWISTING Non wovens PVC Ø 10mm 116 Kg/Km

Tape Total Jacket Weight

Bare copper IEC 332/I Foam Polythylene Tinned copper braid coverage >90% White PVC with numbers Ø 2,6 mm

1X(2X022) MICROPHONE CONSTRUCTION

Black

Inner conductor Insulation Shield Jacket

Bare copper Cross Classe5 IEC228 XLPE nat/red Tinned copper spiral Black PVC Ø 2,8 mm

Minimum bending radius 15X OD

APPLICATION

LA R

ce en er ef R

ROBC-01 50mt.

b La

ROBC-01 50mt.

Set-up A

n io at lic pp A

ROBC-01 50mt. Cameraman

Set-up B

ROBC-01 3mt.

Set-up C (Optional) Cameraman

OBVAN COMPOSITE + AC cables

ROB-C/AC series

SUPER FLEXIBLE JACKET

Typical Applications: OB-Van wiring, audio/video room wiring, local studio controll with AC LINE included COLOUR and PACKAGE Reel 100mt Colour Black

ROB-C 01/AC

3xVHS CONSTRUCTION Inner conductor Insulation Shield Jacket

Tinned copper IEC332/I Foam Polyethylene Tinned Copper Braid, coverage>90% White PVC with numbers Ø=2,60 mm

1X(2X022) MICROPHONE CONSTRUCTION Inner conductor Insulation Shield Jacket

Bare Copper Cross Classe5 IEC228 XLPE Nat/Red Tinned Copper Spiral Black PVC Ø=2,80 mm

3x1,00 CONSTRUCTION Inner conductor Insulation Colours

Bare Copper PVC Ø=2,00 mm Blue, brown, yellow-green

TOTAL TWISTING Tape Total Jacket Weight

Non wovens PVC Ø=11,3 mm 163 Kg/Km

www.referencelaboratory.com

#11

p.68

VIDEO COMPOSITE cables

RFBC series

Fisher Boom

#11

A versatile composite cable. An extremely compact cable featuring two VHS lines, three low profile high quality microphone channel, and a shielded AC power connection. VERY FLEXIBLE. Typical Applications: Films and broadcast mobile to connect with the camera

REFERENCE • RFCB HI.Q: Composite video cable

RFBC01 3 microphone cables 2x0,14 3x1 FROR 2 VHS tape wovens / non- wovens Jacket in PVC COLOUR and PACKAGE Reel 100mt Colour Black

3X1 FROR CONSTRUCTION

MICROPHONE CONSTRUCTION 3X(2X0,14)mm Inner conductor Insulation Tape Shield Jacket Capac. Cond. Cond. Capac. Cond. Shield Impedance

Bare copper cross section 0,14mmq, classe5 XLPE Non wovens Tinned copper coverage >90% PVC black Ø=3,20mm 52 pF/m 89 pF/m 95 Ohm

Inner conductor Insulation Jacket

2 VHS CONSTRUCTION Inner conductor Insulation Shield Jacket Capacitance Impedance

Tinned Copper IEC228 Foam polyethylene Tinned copper braid coverage >95% PVC Ø 2,60mm 56 pF/m 75 Ohm

Bare copper cross section 1,00 mmq PVC Blue, brown, yellow-green PVC black Ø 6,00 mm Minimum bending radius 15X OD

OVERALL Tape Jacket Weight

Non wovens PVC black Ø 16,00 mm IEC 332/1 280 Kg/Km

FISHER BOOM CABLE (a) & RDC CABLE DRUM (b) (c) Optimizing

was obteined a Faster installation & Better improvement for Sound & Video Results Mechelen, 20th July 2003 Stage Track BvBa is specialized in Sound Recording for TV and Film. For our booms Mole & Richardson and Fisher, Reference according our demand and rule fixed the multicore cable RFBC01.Meanwhile we have already make 3 series and 1 film. The results are fantastic and unique. Thanks to this cable, people in Europe can listen at a brilliant and disturbance free sound on Tv and cinema theatre. Working with Reference Laboratory was a pleasure and I advice this to anyone. The service was perfect and the people very friendly. Thanks again Erik Rycken [email protected] camera & microphone

Boom extension / fan

local stage 1 box (c) RFBC01 40 mt (a)

2 main stage (b)

www.referencelaboratory.com

Mixer

p.69

VIDEO CONFERENCE COMPOSITE cables

VIC series #11

Typical Applications: Conference room wiring, portable A/V conference wiring COLOUR and PACKAGE Reel 100mt Colour Black

2xRCA

8x2x0,22

2xRCA CONSTRUCTION Inner conductor Insulation Shield

Bare copper Ø=0,80 mm Foam Polyethylene Aluminium Tape + Tinned Copper Braid PVC Ø=5,80 mm

Jacket

MICROPHONE CONSTRUCTION 8x(2x0,22) Inner conductor Bare Copper, cross section 0,22 mm2, Class5, IEC228 XLPE Nat/Red Insulation Tinned Copper Spiral Shield Black PVC Ø=2,80 mm Jacket

RVIC 01

TOTAL TWISTING Tape Total jacket Weight

Non wovens PVC Ø=17,6 mm 337 Kg/Km

Typical Applications: Conference room wiring, portable A/V conference wiring 2xVHS COLOUR and PACKAGE Reel 100mt Colour Black

8x2x0,22

RVIC 02

2xRCA CONSTRUCTION Inner conductor Insulation Shield

Tinned copper IEC332/I Foam Polyethylene Tinned Copper Braid, coverage>90% White PVC with numbers Ø=2,60 mm

Jacket

MICROPHONE CONSTRUCTION 8x(2x0,22) Bare Copper Class5 Inner conductor IEC228 XLPE Nat/Red Tinned Copper Spiral Black PVC Ø=2,80 mm

Insulation Shield Jacket

TOTAL TWISTING Tape Total jacket Weight

Non wovens PVC Ø=14,8 mm 254 Kg/Km

INTERCOM cables

RCOM-C series #4

This series are 4 wires for intercom field is available also in Polyurethane jacket. Application: long distance intercom connection.

RCOM-C01

RCOM-C02

COLOUR and PACKAGE Reel 100mt Colour Bordeaux

same as RCOM-C01 except shield in foil + tinned braid copper

CONSTRUCTION Inner conductor Insulation Core arrang. Shield Jacket Weight

Bare Copper Cross Section 0,34 mm2 PE red/black+blue/nat Ø=1,60 mm 4 conductors twisted in concentric layers Alu/my foil tape coverage 100% + Drain wire Bordeaux PVC Ø=6,80 mm 61 Kg/Km

ELECTRICAL CHARACTERISTICS Cond.Ohm resistance Cond/cond. capacitance Cond/shield capacitance Insulation resistance Impedance Service temperature

10.000 Mohm x Km 110 Ohm red/blue, 102 Ohm black/white -20°C / +70°C

www.referencelaboratory.com

Istituto Italiano del Marchio di Qualità Low voltage division

Insulated cables and adhesive tapes Test Report n° 01S99A0013(*) Multicore cable mod. RSC # ZH and RSCS # ZH (overall shield)

Product type: Multicore cable for audio applications, not flame-propagating and with low smoke and toxic/corrosive gases emissions.

Tests purpose (determination of): • • • • •

Corrosiveness value of the cable components ➊ Halogen-hydric acids quantities in the cable components ➋ Toxicity value of the cable components ➌ Opacity of the smoke (whole cable) ➍ Flame-propagation resistance (whole cable) ➎

Specifications: ➊ CEI 20-37/3: 1997-09 Part 3 “determination of the corrosi veness value of the gases by pH and conductivity measures” (equivalent to IEC 60754-2); ➋ CEI 20-37/2: 1997-09 Part 2 “determination of the quantity of gaseous halogen-hydric acids”; ➌ CEI 20-37/7: 1997-09 Part 7 “toxicity measures of the gas emissions produced by cables”; ➍ CEI 20-37/4-5: 1997-09 “density measures of the smoke emissions produced by the combustion of electrical cables ”; ➎ CEI 20-22/3: Fire tests on electrical cables - Part 3 “tests on multicore cables”. • The products tested comply with the standards above. • This result is extended to all the models of RSC-ZH and RSCS-ZH series * This is only a partial reproduction; the complete report is available by request*.

www.referencelaboratory.com

ero

cable series...

alogen

where compliance

does mean quality

n io at lic pp A

moke

b La

ow

LA R

ce en er ef R

the L S Z H

fire proof and low smoke emission together with flexibility and outstanding audio response

The full set of cables to be able to design and close a project under the INTERNATIONAL STANDARD

RSC 12ZH

Multicore Cable

* Test report 22 november 1999

Ø 14,1

RSC S12ZH

IEC332.1 & IEC 332.3

Multicore Cable

* Test report 12 november 1999

Ø 14,6

RMC09 ZH

Microphone Cable 110 Ω, 2 Conductors sez. 0,185 mm2 (48 x 0,70) Red Copper LSZH Double Braided

Ø 5,50

RPLC05 ZH REFERENCE • RPLC05ZH

HI.Q:

AC/LINE cable 3 x 1,50 + 2 x AWG22 (TWIN) * Italian Istitute for Quality

RDNT02 ZH

75 Hom Coaxial for new format video digital

Ø 4,50

RVC01 ZH

75 Hom Coaxial video RG 59

Ø 6,10

RPC08 ZH • • • • • •

QUALITY SYSTEM CERTIFICATE

standard

ISO 9002/EN2902

Insulation resistance a 20°C Capacitance Ohm. Cond. Resistance Temperature range Nominal Voltage Test Voltage

>200 Mohm*Km 70 pF/m 7,7 Ohm/Km -30°C + 70°C 50 V 3000 V

2X2,5 FROR - RPC08 ZH

RPC09 ZH • • • • • •

Insulation resistance a 20°C Capacitance Ohm. Cond. Resistance Temperature range Nominal Voltage Test Voltage

>200 Mohm*Km 70 pF/m 7,7 Ohm/Km -30°C + 70°C 50 V 3000 V

4X2,5 FROR - RPC09 ZH

www.referencelaboratory.com

p.72

#12

MULTICORE cables

RSC ZH series RSC-S ZH series

Low Smoke Zero Halogen

The RSC/ZH Series of multichannel microphone cables offers the same advantages and performance of the traditional RSC models. The LSZH insulation material used makes it a mandatory choice where permanent installations are needed – especially public spaces and professioanal audio permanent wiring as studio mixing consoles and equipment. Typical Applications: Pro audio permanent installations, public sites (hospitals, theaters, cinemas,…). Complying to:

ASIM B33-91 CEI 20-11 CEI 20-34 CEI 20-35 / IEC 332.1 CEI 20-22 III / IEC 332.3 CEI 20-27 I / IEC 754.1 CEI 20-37 III-A / IEC1034 CEI 20-37 II

tinned copper termoplastic compound characteristics tests methods for thermoplastic materials flame propagation fire propagation hydrochloric acid emissions smoke opacity toxic gases emission

QUALITY SYSTEM CERTIFICATE

standard

ISO 9002/EN2902

CONSTRUCTION and ORDERING Codes Mod. mod. RSC/ZH 12

Pairs 12

Reel 100 m

Colours Gr (grey)

SPECIFICATIONS Capacitance cond/cond Capacitance cond/screen Cond. D.C.R. Screen type (each pair) Shield D.C.R. Nom. Impedance Attenuation @ 1MHz Working temp. range AWG # / Area [mm2] Qty /mm O.D. / jacket material Ch. O.D. [mm]/ insul.type Pair O.D. [mm]/insul. type Weight

Channel Drain wire

80 [pF/m] 150 [pF/m] 0.083 [Ω/m] Tinned copper (lap 100%) 0.04 [Ω/m] 75 [Ω] 2.1 [dB/100m] -40 / +80 [°C] AWG 24 / 0.22 - 28/0.10 (tinned copper) AWG 24 / 0.20 - 18/0.12 (tinned copper) 14,00 [mm] / LSZH thermoplastic 1.0 / PE 2.9 /LSZH thermoplastic 230 Kg/Km

RSCS - ZH same specification + overall screen CORE N° 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

COLOUR OF ONE OF THE PAIR Brown Red Orange Yellow Green Blue Purple Grey White Black Brown Red Orange Yellow Green Blue

CORE JACKET COLOUR

White

Grey

www.referencelaboratory.com

CORE N° 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

COLOUR OF ONE OF THE PAIR Purple Grey White Black Brown Red Orange Yellow Green Blue Purple Grey White Black Brown Red

CORE JACKET COLOUR Grey

Red

Orange

CORE N° 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

COLOUR OF ONE OF THE PAIR Orange Yellow Green Blue Purple Grey White Black Brown Red Orange Yellow Green Blue Purple Grey

CORE JACKET COLOUR

Orange

Yellow

p.73

MULTICORE cables

RPLC ZH series

Low Smoke Zero Halogen AC/LINE

#12

The RPLC05 is designed, to meet the standard safety requirements where LSZH materials are specificated. Typical Applications: Pro audio permanent installations, public sites (hospitals, theaters, cinemas,…). Complying to: IEC 228 red copper CEI 20-11 thermoplastic compound characteristics CEI 20-34 tests methods for thermoplastic materials CEI 20-35 / IEC 332.1 flame propagation CEI 20-22 III / IEC 332.3 fire propagation CEI 20-27 I / IEC 754.1 hydrochloric acid emissions CEI 20-37 III-A / IEC1034 smoke opacity CEI 20-37 II toxic gases emission

REFERENCE • RPLC 05 ZH

CONSTRUCTION and ORDERING Codes Mod. RPLC/ZH 05, 2 x 0,34 + 3 x 1,50

Reel 100m

Colours Bk (black)

SPECIFICATIONS SPECIFICATION 40 [pF/m] < 0,6 mH/Km 0.056 [Ω/m] Foil (Al-My, 100%)+ Braided (tinned copper, >9 0%) 0.018 [Ω/m] 110 [Ω] PE 1000 [V] AWG 22 / 0.34 (red copper) > 100 MΩ/Km AWG 15 / 1.50 (red copper) NPI PVC (IEC 332.1) LSZH thermoplastic -20 / +70 [°C] 202 [Kg/Km]

Shield D.C.R. Nom. Impedance Insulation material Max. oper. Voltage AWG # / Area [mm2] Insulation resistance AWG # / Area [mm2] Conductor insulation Overall jacket insulation material Working temp. range Weight

SPEAKER cables

Microphone section

Capacitance Inductance Cond. D.C.R. Screen type

AC power section

RPLC ZH series

LSZH

#12

Designed for amplifier to loudspeaker connections, the RPC cables can really make the difference when maximum power transfer, superior sonic transparency , and mechanical reliability are essential. The RPC LSZH Speaker Series offers the same sonic quality of traditional RPC Series but is intended for permanent installations. Typical applications: For fixed audio installations. Available colour: Gr (grey) and bk(black).

REFERENCE • RPC 08 LSZH

CONSTRUCTION / MECHANICAL MODEL AWG# / Area Cond. D.C.R. Capacitance [mm ]*

[Ω/Km]

[pF/m]

2 x 2,5 (AWG13) 4 x 2,5 (AWG13)

200 -30/+70 Jacket

Size [mm]

Weight [Kg/100Mt]

10 12

13,6 23,5

www.referencelaboratory.com

p.74

MICROPHONES cables

RMC ZH series

Low Smoke Zero Halogen

#12

RMC09 ZH is designed to supply the balance line into the fixed installation where are required LSZH materials.Its electric performance is able to cover also long distance with lower loss and wider frequency response. Typical applications: fixed installations. Complying to: IEC 228 red copper CEI 20-11 termoplastic compound characteristics QUALITY SYSTEM CEI 20-34 tests methods for thermoplastic materials CERTIFICATE CEI 20-35 / IEC 332.1 flame propagation CEI 20-22 III / IEC 332.3 fire propagation CEI 20-27 I / IEC 754.1 hydrochloric acid emissions standard CEI 20-37 III-A / IEC1034 smoke opacity ISO 9002/EN2902 CEI 20-37 II toxic gases emission

RMC 09

CONSTRUCTION and ORDERING Codes Mod. RMC 09/ZH

Pair 1

Reel 100m

Colours Bk (black)

SPECIFICATIONS SPECIFICATION Cond. D.C.R. 1st screen 2nd screen Shield D.C.R. AWG # / Area [mm2] Qty /mm Ch. O.D. [mm]/ insul.type Fillers O.D. / jacket material Nom. Impedance Working temp. range

www.referencelaboratory.com

0.083 [Ω/m] Lap (clockwise, 100% opt. coverage) Lap (counterclockwise, >95% opt. coverage) 0.04 [Ω/m] AWG 24 / 0.185 48/0.07 (red copper) 1.8 / PP LSZH soft material 5,50 [mm] / LSZH thermoplastic 110 [Ω] -40 / +80 [°C]

p.75

VIDEO cables

RVC ZH series

Low Smoke Zero Halogen

#12

The RVC ZH coaxial cable offers the same advantage and performances of traditional RVC models . The LSZH insulation material makes it mandatory where permanent installations are needed. Typical applications: Video fixed installation,TV,post production. Complying to: ASIM B33-91 tinned copper IEC 228 red copper CEI 20-11 termoplastic compound characteristics CEI 20-34 tests methods for thermoplastic materials CEI 20-35 / IEC 332.1 flame propagation CEI 20-22 III / IEC 332.3 fire propagation CEI 20-27 I / IEC 754.1 hydrochloric acid emissions CEI 20-37 III-A / IEC1034 smoke opacity CEI 20-37 II toxic gases emission

RVC 01/ZH

CONSTRUCTION and ORDERING Codes Mod. RVC 01/ZH

Coax. RG59 B/U type

Reel 100m

Colours Black

SPECIFICATION SPECIFICATIONS Inner conductor AWG # / Area [mm2] Cond. D.C.R. Inner conductor insulation 1st Screen type Screen D.C.R. 2nd screen type Capacitance Impedance Propagation velocity Max. oper. voltage Insulation resistance O.D./ outer jacket material Working temp. range Weight

Solid red copper AWG 19 / 0.60 (red copper) 0.063 [Ω/m] PE Braided (red copper, opt. coverage >9 5%) 0.0063 [Ω/m] Braided (tinned copper, opt. coverage >95%) 66 [pF/m] 75 [Ω] 65% 3 [KVolt] > 10000 MΩ/Km 6,1 [mm] / LSZH thermoplastic -30 / +80 [°C] 58 [Kg/Km]

www.referencelaboratory.com

p.76

VIDEO cables

RDNT series

Low Smoke Zero Halogen Coaxial Digital SDI

#12

High quality, very low attenuation 75ohm video coaxial cable with double screen for effectiveRFI and EMI interference rejection. LSZH insulation material makes the definitive solution for permanent installations. The same top audio quality provided by it’s general purpose twin RDNT01 is guaranteed. Typical applications: any public and private space permanent TV network installation. Complying to:

ASIM B33-91 IEC 228 CEI 20-11 CEI 20-34 CEI 20-35 / IEC 332.1 CEI 20-22 III / IEC 332.3 CEI 20-27 I / IEC 754.1 CEI 20-37 III-A / IEC1034 CEI 20-37 II

tinned copper red copper thermoplastic compound characteristics tests methods for thermoplastic materials flame propagation fire propagation hydrochloric acid emissions smoke opacity toxic gases emission

RDNT 02/ZH

CONSTRUCTION and ORDERING Codes Mod. RDNT 02/ZH

Video Coax. 75 ohm

Reel 100m

Colours Green

SPECIFICATIONS Inner conductor AWG # / Area [mm2] Cond. D.C.R. Inner conductor insulation 1st Screen type 2nd screen type Screen D.C.R. Capacitance Impedance Propagation velocity O.D./ outer jacket material Working temp. range Weight

PUR series

Solid red copper AWG 19 / 0.30 (red copper) 0.060 [Ω/m] PE Alluminium tape (wonded) Braided (tinned copper, opt. coverage >90%) 0.017 [Ω/m] 56 [pF/m] 75 [Ω] 80% 4,5 [mm] / LSZH thermoplastic -30 / +80 [°C] 5,8 [Kg/100Mt]

POLYURETHANE cables

#13

Reference Laboratory is always looking for innovative construction techniques and materials to serve the effective answers for professional applications. This is the first time that polyurethane materials are used. In fact they bring quite a few benefits as: • wide temperature range (-40/+80°C) • nice touch feeling • high abrasion hardness • high resistance to mineral oils • mechanical reliability • nice aspect (light absorbing surface) RMC-13 PUR Suited for long cable runs as in delay line connections. It brings extra advantages as it has a high abrasion hardness, it is skein-friendly and mechanically reliable RDMX01 PUR This cable is an excellent solution for high quality balanced data connections (like DMX protocoll in ligthing applications) REFERENCE • RDMX01 PUR HI.Q:

RDMX01 PUR

RMC 13 PUR www.referencelaboratory.com

REFERENCE • RMC13 PUR HI.Q

p.77

POLY cables

POLYCAB series #13

Reference Laboratory is always looking for innovative construction techniques and materials to serve the effective answers for professional applications. The new “POLY-CABLE” family features two series named Polycab and Microfly. This is the first time that polyurethane materials are used. In fact they bring quite a few benefits as: • high flexibility over a wide temperature range (-40/+80°C) • nice touch feeling • high agrasion hardness • high resistance to mineral oils • mechanical reliability • nice aspect (light absorbing surface) RMC-11

PolyCab. Suited for long cable runs as in delay line connections. It brings extra advantages as it has a high abrasion hardness, it is skein-friendly and mechanically reliable RMCQ-02 PolyCab This QUAD cable is an excellent solution for high quality balanced connections in live applications also thanks to its good behaviour when made into skeins. RMIC-05 MicroFly Best solution for microphone connections with mobile stage designs (TV, Theatre), where abrasion hardness, lightness, flexibility, and mechanical reliability are a must. RIC-11 PolyCab The answer for the most demanding and dynamic guitar players. It also shows an excellent touch feeling at very low operating temperatures.

SPECIFICATIONS Capacitance cond/cond Capacitance cond/screen Inductance Cond. D.C.R. Screen type Nom. Impedance Insulation material Test voltage Insulation resistance AWG # / Area O.D. / Overall jacket insulation material Working temp. range Weight

RMIC05

RIC11

[kV] [MΩ/Km] [mm2] Qty x [mm]. [mm]

50 87 100 AWG22 / 0,34 red copper 6 / black TPF

46 78 100 AWG24 / 0,22 red copper 6 / black TPF

52 89 7000 Ohm*Km 66% -20°C +60°C

Typical Applications: Mobile installation, Ethernet connection

REFERENCE • RSFTP02F

RSFTP02F COLOUR and PACKAGE Reel 100mt Colour Black

CONSTRUCTION Inner conductor Insulation Drain Wire Tape Shield Shield Jacket

RSFTP-SF series

Solid Bare Copper AWG24 Polyolephyne Solid Tinned Copper Polyestere Aluminium Tape/Polyestere Foil coverage 100% Tinned Copper Braid PVC Ø 6,2 mm

ELECTRICAL CHARACTERISTICS Cond. Ohm resistance Capac. Between conductors Insulation resistance Propagation velocity Temperature range

77 Ohm/Km 62 pF/m >7000 Ohm*Km 66% -20°C +60°C

Ethernet FTP Super Flex cables

#12

Typical Applications: Mobile installation, Ethernet connection with Super Flexible performance

RSFTP02 SF COLOUR and PACKAGE Reel 100mt Colour Blue

CONSTRUCTION 4x2x24 AWG Inner conductor Insulation Tape Shield Jacket

www.referencelaboratory.com

Bare Copper cross section 0,22 mm2 PVC Ø=1,00 mm white+white-green/orange+white-orange/ blue+white-blue/brown+white-brown Cotton Tape Bare Copper spiral Black PVC Superflex Ø=6,00 mm

ELECTRICAL CHARACTERISTICS Cond.Ohm resistance Insulation resistance Capacitance between cond. Capacity cond./shield Temperature range

86 Ohm/Km >40 Ohm*Km 97pF/m 152pF/m -20°C / +60°C

p.79

Ethernet Cat6

FTP series #12

Typical Applications: Ether Sound and Data Net Applications

Drain Wire Foil Copper Braid

RS-FTP-05

Drain Wire Foil

R-FTP-04

Inner conductor Insulation Drain wire Tape Shield Shield Jacket COLOUR and PACKAGE Reel 100mt Colour Grey

R-UTP-03

Ethernet cables

CONSTRUCTION 4x2x24 AWG Solid Bare Copper Polyethylene Tinned copper Polyester Aluminium/Polyester foil, coverage >100% Tinned copper braid PVC Ø=7,00 mm Grey RAL 7035 ELECTRICAL CHARACTERISTICS Cond.Ohm resistance 77 Ohm/Km Insulation resistance >7000 Ohm*Km Capacity between conductors 62pF/m Propagation velocity 66% Range temperature -20°C / +60°C

LIVE series #12

Live series Reference Ethernet cable is a NEW series designed for Live applications as today required the last technologies in audio transmission and control under Ethernet protocol. All Reference Live series cables are manufactured with special compound for give better flessibility, life time without changing the electrical and mechanical characteristics. We also sell this cable, for give total solution, assembled with Reference cable drum (RDC or RDQC series) and Neutrik Rj connectors Typical Applications: Ethernet CAT5e connection between stage unit and FOH - Digital console - Line array control

REFERENCE • REL-01 HI.Q: Ethernet

REL-01

CONSTRUCTION 4X2X022mmq Inner conductor Solid Bare Copper Insulation Polyolephyne Stranding Cores twisted to a pair Inner jacket TPE Jacket XLPE O.D. 6,0mm -mini. bending radius 8xOD COLOUR and PACKAGE Reel 100mt Colour Black

ELECTRICAL CHARACTERISTICS Cond.Ohm resistance 7000 Ohm*Km Capacity between conductors 53pF/m Range temperature -20°C / +70°C

www.referencelaboratory.com

p.80

Ethernet cables

LIVE series #12

Ethernet cable CAT5e designed for LIVE application as many digital console and some line array today request Typical Applications: Ethernet connection between stage unit and FOH - Digital console - Line array control

CONSTRUCTION

RSF DE01

Inner conductor Insulation Drain Wire Shield Overall Jacket

Solid Bare Copper AWG24 XLPE PVC Ø 14,50mm, Black

ELECTRICAL CHARACTERISTICS Cond. Ohm resistance Capac. Between conductors Insulation resistance Propagation velocity Temperature range

77 Ohm/Km 53 pF/m >7000 Ohm*Km 66% -20°C +70°C

As RSFDE01 Plus including N.2 balanced line cable for utility ( like intercom and or DMX data) Typical Applications: Ethernet connection between stage unit and FOH - Digital console - Line array control

RSF DE02 COLOUR and PACKAGE Reel 100mt Colour Black

CONSTRUCTION Inner conductor Insulation Drain Wire Tape Shield Overall Jacket

Solid Bare Copper AWG24 XLPE Polyestere PVC Ø 14,50mm, Black

AUDIO CONSTRUCTION Inner conductor Insulation Drain Wire Shield Jacket

www.referencelaboratory.com

Bare Copper 022 XLPE Tinned Copper Foil PVC Ø 2,80mm, Black

ELECTRICAL CHARACTERISTICS Cond. Ohm resistance Capac. Between conductors Insulation resistance Propagation velocity Temperature range Minimum bending radius

77 Ohm/Km 53 pF/m >7000 Ohm*Km 66% -20°C +70°C 15X OD

p.81

Composite Multi Video Coax RGB + AC 3x1,00 cables Typical Applications: Installations/video projector

AC 3x1,00

2 VIDEO

3 VIDEO RGB

RGB05/AC/I

COLOUR and PACKAGE Reel 100mt

RGB/AC/I series #11

VIDEO CONSTRUCTION Tinned copper

Inner conductor Insulation

Foam Polyethylene

Shield

Tinned Copper Braid, coverage>95%

Colour Jacket

PVC Ø=2,60 mm

2 Video Jacket

PVC Ø=7,00 mm black

3 Video RGB Jacket

PVC Ø=7,40 mm black

Inner conductor Insulation Jacket

AC CONSTRUCTION Bare Copper Cross Section 1,00 mm PVC Blue/brown/yellow/green Black PVC Ø=6,40mm

Colour

OVERALL

Black

External diameter Jacket

7,40 mm x 20,80 All the PVC jacket are CEI2022 or under requirement CEI2037

INDUSTRY cables

RC72 series #12

Halogen free Installation cable for industries, hotels, airports, hospitals. Application: Security network - Emergency controls - Fire allarm controls - Light controls Normative References: BT73/23 CEE e 93/63 Drain Wire PVC Hal-Free All/Foil solid copper

RC72-2x4x06

CONSTRUCTION Conductors Jacket Shielding Drain wire Overall OD mm Rated Temp. Nominal voltage Bend radius

RC72-1x4x06

RC72-1x4x06

RC72-1x4x08

4 solid red copper 0,6 Coloured PE Foil Tinned copper PVC Hal-Free 5 60° 300V 10xOD

4xsolid red copper 0,8 Coloured PE Foil Tinned copper PVC Hal-Free 5,6 60° 300V 10xOD

RC72-2x4x06 2x4xsolid red copper 0,6 Coloured PE Foil Tinned copper PVC Hal-Free 8,9 60° 300V 10xOD

REF07 cable #12

This cable i s for fixed installation on industries fields when the space is very important (like shipyards, airports, hotels, conference rooms).

REF 07

VIDEO SECTION Conductor Insulation Shield Jacket

2XRG6 red copper imm XLPE Alu - Foil + Tinned braid copper Pvc

ETHERNET SECTION 6xCAT5e Solid red copper XLPE coloured standard CAT5e ALU-FOIL+Tinned braid copper + drain wire PVC coloured

OVERALL Jacket PVC blue O.D. 22,5 mm Minimum bend radius 15xOD

www.referencelaboratory.com

p.82

ASSEMBLED cables

E CABLE PRE MADRENCE REFTEESTED AND

• 100% TESTED BEFORE SHIPPING • ALL JAKS REFERENCE AND REFERENCE/AMPHENOL (TM series) MADE WITH TIP MACHINED - SOLDER AREA IN ONE BODY • 100% RoHS COMPLIANTS

by by

W/PVC sleeve*

optional colours sleeve Y/R

by

W/metal sleeve

by W/spring metal sleeve

We will do custom lenghts premade cable with a minimum order www.referencelaboratory.com

all the above plugs are available in mono and stereo version

p.83

ASSEMBLED cables

DO YOU KNOW WHAT s t r a p p e r™ IS? • • • •

It’s a strongest velcro “pre assembled” w/cables, then it remain It’s an addition value to faster identification cable’s lenght whit color’s cable It increasing the cable’s life time because it replace any tapes His line has been projected to cover all cables types as: microphones, guitar, speaker and multicore

R-206

For microphone and guitar cable max jacket overall diameter 6,50 mm

Blue for 4,5-5 mt cable’s lenght Black for 10 mt cable’s lenght Yellow for 15 mt cable’s lenght Red for 20 mt cable’s lenght

Ø 7 mm

R-CF 3/4

Lenght 16 cm

For multicore and speaker cable max jacket overall diameter 15,50 mm

Yellow for 15 mt cable’s lenght Red for 20 mt cable’s lenght

Ø 16 mm

R-CF 1x6

Lenght 18 cm

For multicore and speaker cable max jacket overall diameter 15,50 mm

Grey for 20 mt cable’s lenght

Ø 16 mm

R-CF 1x12

Lenght 25 cm

For multicore and speaker cable max jacket overall diameter 15,50 mm

Yellow for 15 mt cable’s lenght

Ø 16 mm

R-CF 1x17

Lenght 33 cm

For multicore speaker cable max jacket overall diameter 15,50 mm

Yellow for 15 mt cable’s lenght Red for 20 mt cable’s lenght

Ø 16 mm

29”x1-1/2

Lenght 43 cm

For multicore and video speaker cables

Fluorescent

Lenght 73 cm

www.referencelaboratory.com

p.84

RIC01 series

ASSEMBLED INSTRUMENTS cables

This CLASSIC series are manufactured with RIC01 cable and gold metal jacks. Available in different lengths and jacks. Applications: Hi-end guitar and instrument cable with flat response and free noise. ideal in recording studio, home recording and live. Benefits: Robust construction - Low capacitance - Double shield (Copper + semiconductor PVC) - Hi flexibility - No memory. Reference jacks: consist in Two gold metal jacks with PVC Sleeve.

Standard configuration

AVAILABLE LENGTH Code metres feet

RIC01-JJ-4,5 4,5 14,7

RIC01-JJ-6 6 19,7

RIC01-JJ-10 10 32,8

RIC01-JJ-15 15 49,2

RIC01-JJ-20 20 65,6

Amphenol jacks: consist in two TM series gold metal jacks with JAWS and black finish sleeve.

Standard configuration

AVAILABLE LENGTH Code metres feet

RIC01-JJ-AU-4,5-A 4,5 14,7

RIC01-JJ-AU-6-A 6 19,7

RIC01-JJ-AU-10-A 10 32,8

RIC01-JJ-AU-15-A 15 49,2

RIC01-JJ-AU-20-A 20 65,6

Available also with (for code follow price list): AMPHENOL Nickel jacks NEUTRIK Nickel jacks Amphenol jacks: consist in ONE TM series gold metal jacks with JAWS and nickel finish sleeve and ONE Reference jack right angle gold metal nickel sleeve.

Standard configuration

AVAILABLE LENGTH Code metres feet

RIC01-JJr-AU-4,5 4,5 14,7

RIC01-JJr-AU-6 6 19,7

RIC01-JJr-AU-10 10 32,8

RIC01-JJr-AU-15 15 49,2

RIC01-JJr-AU-20 20 65,6

Available also with (for code follow price list): AMPHENOL/REFERENCE Nickel jacks NEUTRIK /NEUTRIK Nickel jacks SWITCHCRAFT/SWITCHCRAFT Nickel jacks

ASSEMBLED EFFECT PEDALS cables Standard configuration. For best result we use RIC01 cables and Reference Gold finish right angle jacks. Other jacks and lenghts on request. Available length: metres 0,3 0,5 feet 1 1,6 RIC01JrJr-AU -03 RIC01JrJr-AU -05

Available also with cable: RICS01R, RICS01, RIC09T

www.referencelaboratory.com

p.85

ASSEMBLED INSTRUMENTS cables

RIC-S01 series

This SOLID series are manufactured with RIC-01 cable and gold metal jacks. Available in different lengths and jacks. Applications: Recording Studios - Home recording studios. Thanks at the SOLID technology this cable is designed for have uncoloured sound in studio applications as musician requested. Benefits: Robust construction- Low capacitance - Double shield (Copper + semiconductor PVC) - Hi flexibility -No memory. Reference jacks: consist in Two gold metal jacks with PVC Sleeve.

Standard configuration

AVAILABLE LENGTH Code metres feet

RICS01-JJ-4,5 4,5 14,7

RICS01-JJ-6 6 19,7

RICS01-JJ-10 10 32,8

RICS01-JJ-15 15 49,2

RICS01-JJ-20 20 65,6

Amphenol jacks: consist in two TM series gold metal jacks with JAWS and black finish sleeve.

Standard configuration

AVAILABLE LENGTH Code metres feet

RICS01-JJ-AU-4,5-A 4,5 14,7

RICS01-JJ-AU-6-A 6 19,7

RICS01-JJ-AU-10-A 10 32,8

RICS01-JJ-AU-15-A 15 49,2

RICS01-JJ-AU-20-A 20 65,6

Available also with (for code follow price list): AMPHENOL Nickel jacks NEUTRIK Nickel jacks Amphenol jacks: consist in ONE TM gold metal jacks with JAWS and black finish sleeve and ONE Reference jack right angle gold metal nickel sleeve.

Standard configuration

AVAILABLE LENGTH Code metres feet

RICS01-JJr-AU-4,5 4,5 14,7

RICS01-JJr-AU-6 6 19,7

RICS01-JJr-AU-10 10 32,8

RICS01-JJr-AU-15 15 49,2

RICS01-JJr-AU-20 20 65,6

Available also with (for code follow price list): AMPHENOL/REFERENCE Nickel jacks NEUTRIK /NEUTRIK Nickel jacks SWITCHCRAFT/SWITCHCRAFT Nickel jacks

www.referencelaboratory.com

p.86

RIC-01A series

ASSEMBLED INSTRUMENTS cables

This series are manufactured with RIC01A cable and gold metal jacks. Available in different lengths and jacks. Applications: Recording Studios - Home recording - Live. A NEWS CONCEPT of Reference Cables. RIC01A combined lasted technology and experience to give you what you really want - They delivered definition sound at any frequencies, it is specific for ACOUSTIC GUITAR. Benefits: Robust construction- Low capacitance - Double shield (Copper + semiconductor PVC) - Hi flexibility -No memory. Amphenol jacks: consist in two TM gold metal jacks with JAWS and Nickel finish sleeve.

Standard configuration

AVAILABLE LENGTH Code metres feet

RIC01A-JJ-AU-4,5-A 4,5 14,7

RIC01A-JJ-AU-6-A 6 19,7

RIC01A-JJ-AU-10-A 10 32,8

RIC01A-JJ-AU-15-A 15 49,2

RIC01A-JJ-AU-20-A 20 65,6

Available also with (for code follow price list): AMPHENOL Black jacks NEUTRIK Nickel jacks Amphenol jacks: consist in ONE TM gold metal jacks with JAWS and nickel finish sleeve and ONE Switchcraft jack right angle nickel.

Standard configuration

AVAILABLE LENGTH Code metres feet

RIC01A-JJr-4,5 4,5 14,7

RIC01A-JJr-6 6 19,7

RIC01A-JJr-10 10 32,8

RIC01A-JJr-15 15 49,2

RIC01A-JJr-20 20 65,6

Available also with (for code follow price list): NEUTRIK /NEUTRIK Nickel jacks SWITCHCRAFT/SWITCHCRAFT Nickel jacks

RIC-01V VINTAGE series

ASSEMBLED INSTRUMENTS

cables

This series are manufactured in Spiral for give at Musicians a vintage look with all Reference know how. Available in one length (approx: 80 cm close spiral - 3,5 mt all extension)

Vintage cable is available with Amphenol jacks Model TM2PBM-AU (Black finish - Gold contact with metal backshell)

www.referencelaboratory.com

p.87

ASSEMBLED INSTRUMENTS cables

RIC-S01R series

This SOLID series are manufactured with RIC-S01 cable and gold metal jacks. Available in different lengths and jacks. Applications: Recording Studios - Home recording studios. RED cables uses a unique coax solid wire copper design to deliver the lowest capacitance and very transparent tone without any tonal distortion, as a rock guitarist like have. Benefits: Robust construction- Low capacitance - Double shield (Copper + semiconductor PVC) - Hi flexibility -No memory. Reference jacks: consist in Two gold metal jacks with PVC Sleeve.

Standard configuration

AVAILABLE LENGTH Code metres feet

RICS01R-JJ-4,5 4,5 14,7

RICS01R-JJ-6 6 19,7

RICS01R-JJ-10 10 32,8

RICS01R-JJ-15 15 49,2

RICS01R-JJ-20 20 65,6

Amphenol jacks: consist in two TM series gold metal jacks with JAWS and black finish sleeve.

Standard configuration

AVAILABLE LENGTH Code metres feet

RICS01R-JJ-AU-4,5-A 4,5 14,7

RICS01R-JJ-AU-6-A 6 19,7

RICS01R-JJ-AU-10-A 10 32,8

RICS01R-JJ-AU-15-A 15 49,2

RICS01R-JJ-AU-20-A 20 65,6

Available also with (for code follow price list): AMPHENOL Nickel jacks NEUTRIK Nickel jacks

Amphenol jacks: consist in ONE TM series gold metal jacks with JAWS and black finish sleeve and ONE Reference jack right angle gold metal nickel sleeve.

Standard configuration

AVAILABLE LENGTH Code metres feet

RICS01R-JJr-4,5 4,5 14,7

RICS01R-JJr-6 6 19,7

RICS01R-JJr-10 10 32,8

RICS01R-JJr-15 15 49,2

RICS01R-JJr-20 20 65,6

Available also with (for code follow price list): AMPHENOL/REFERENCE Nickel jacks NEUTRIK /NEUTRIK Nickel jacks SWITCHCRAFT/SWITCHCRAFT Nickel jacks

www.referencelaboratory.com

p.88

ASSEMBLED INSTRUMENTS cables

RIC-09T series

This series are manufactured with RIC-09T cable and gold metal jacks. Available in different lengths and jacks. Applications: Guitars, keyboards, foot pedals and all unbalanced connections design to deliver the lowest capacitance and very transparent tone without any tonal distortion, born for all live performance and rental company use. Benefits: Robust construction - Double shield (braid Copper + semiconductor PVC) - Hi flexibility - No memory. Amphenol jacks: consist in two TM series gold metal jacks with JAWS.

Standard configuration

AVAILABLE LENGTH Code metres feet

RIC09TJJ-AU-4, 5-A 4,5 14,7

RIC09T-JJ-AU-6-A 6 19,7

RIC09T-JJ-AU-10-A 10 32,8

RIC09T-JJ-AU-15-A 15 49,2

RIC09T-JJ-AU-20-A 20 65,6

Available also with: (for code follow price list): AMPHENOL Nickel jacks Neutrik Nickel jacks and Reference jacks in metal + PVC backshell Amphenol jacks: consist in ONE TM series gold metal jacks with JAWS and ONE Reference jack right angle gold metal nickel sleeve

Standard configuration

AVAILABLE LENGTH Code metres feet

RIC09T-JJr-4,5 4,5 14,7

RIC09T-JJr-6 6 19,7

RIC09T-JJr-10 10 32,8

RIC09T-JJr-15 15 49,2

RIC09T-JJr-20 20 65,6

Available also with: (for code follow price list): NEUTRIK /NEUTRIK Nickel jacks AMPHENOL /SWITCHGRAFT Nickel jacks SWITCHCRAFT/SWITCHCRAFT Nickel jacks

RPCM series

ASSEMBLED HEAD-CABINET

cables

This series are manufactured with RPCM02 /RPCM03 cable and REFERENCE metal jacks. Designed for connect any guitars or/and bass amplifiers to the rispective cabinet. Applications: Live - Studio The RPCM series speaker cable use the multistrand technology witch privileges a high number of strands of very thin capillary wires. This means maximum sonic transparency and power transfer over a wider frequency range. Assembled with: Reference jacks RPPS500.

Standard configuration: RPCM01 (2x3.3) RPCM03 (2x5.22)

AVAILABLE LENGTH Code Code metres feet

RPCM01 TR/FU JJ-1 RPCM03 TR/FU JJ-1 1 3,28

RPCM01 TR/FU J-J-1.5 RPCM03 TR/FU J-J-1.5 1.5 4,9

RPCM01 TR/FU JJ-2 RPCM03 TR/FU JJ-2 2 6,5

For code and model please follow price list - others length on request. Available also with: JACK/SPEAKON SPEAKON/SPEAKON. And with RPC09(4x2.5) for biamp cabinets. www.referencelaboratory.com

p.89

ASSEMBLED MICROPHONE cables

RMC01 series

This series are manufactured with RMC01 cable and Amphenol connectors. Available in different lengths. Applications: Recording studio - Home recording - On stage - Rental company. Benefits: Robust construction - Low capacitance - Lap shield AWG20 - Amphenol XLR with machined male pins.

Standard configuration

AVAILABLE LENGTH Code metres feet

RMC01-MF-5 5 16,4

RMC01-MF-10 10 32

RMC01-MF-15 15 49,2

RMC01-MF-20 20 65,6

Available also with: NEUTRIK XLR

ASSEMBLED MICROPHONE cables

RMC07TW series

This series are manufactured with RMC07TW cable and Amphenol connectors. Available in different lengths. Applications: Recording studio - Home recording - On stage - Rental company. Benefits: Robust construction - Low capacitance - Lap shield AWG22 - Amphenol XLR with machined male pins.

Standard configuration

AVAILABLE LENGTH Code metres feet

RMC07TW-MF-5 5 16,4

RMC07TW-MF-10 10 32

RMC07TW-MF-15 15 49,2

RMC07TW-MF-20 20 65,6

Available also with: NEUTRIK XLR

ASSEMBLED MICROPHONE cables

RMC15TP series

This series are manufactured with RMC15TP cable and Amphenol connectors. Available in different lengths. Applications: Recording studio - Home recording studios - On stage - Rental company. Benefits: Robust construction - Low capacitance - Braid shield AWG26- Short twist pitch - Amphenol XLR with machined male pins - Hi flexibility - No memory - Overall cable diameter 4.6 mm.

Standard configuration

AVAILABLE LENGTH Code metres feet

RMC15TP-MF-5 5 16,4

RMC15TP-MF-10 10 32

RMC15TP-MF-15 15 49,2

RMC15TP-MF-20 20 65,6

Available also with: NEUTRIK XLR www.referencelaboratory.com

p.90

RMC16TP series

ASSEMBLED MICROPHONE cables

Standard configuration. Others configuration on request. This series are manufactured with RMC16TP cable and Amphenol connectors. Available in different lengths. Applications: Recording studio - Home recording - On stage - Rental company. Benefits: Robust construction - Low capacitance - H density braid shield AWG24 - Short twist pitch Amphenol XLR with machined male pins - Hi flexibility - No memory - Overall cable diameter 6.0 mm.

Standard configuration

AVAILABLE LENGTH Code metres feet

RMC16TP-MF-5 5 16,4

RMC16TP-MF-10 10 32

RMC16TP-MF-15 15 49,2

RMC16TP-MF-20 20 65,6

Available also with: NEUTRIK XLR

RMCS01 series

ASSEMBLED MICROPHONE cables

Standard configuration. Others configuration on request. This series are manufactured with RMCS01 cable and Amphenol connectors. Available in different lengths. Applications: Recording studio - Home recording. Benefits: Thanks to Solid technology this cable is intended for studio application - Amphenol XLR with machined male pins - Hi flexibility - No memory - Overall cable diameter 7.0 mm.

Standard configuration

AVAILABLE LENGTH Code metres feet

RMCS01-MF-5 5 16,4

RMCS01-MF-10 10 32

RMCS01-MF-15 15 49,2

RMCS01-MF-20 20 65,6

Available also with: NEUTRIK XLR

RMCL series

ASSEMBLED MICROPHONE cables

Standard configuration. Others configuration on request. This series are manufactured with RMLC SERIES cable and Amphenol connectors. Available in different lengths. The RMCL series consist: RMLC02 - RMLC03 - RMLC05 Applications: On stage - Rental company - Band Benefits: Robust construction- Low capacitance - AWG22 - Amphenol XLR with machined male pins - Hi flexibility - No memory - Overall cable diameter 6.0 mm.

Standard configuration

AVAILABLE LENGTH Code metres feet

RMLCXX-MF-5 5 16,4

Available also with: NEUTRIK XLR www.referencelaboratory.com

RMLCXX-MF-10 10 32

RMLCXP-MF-15 15 49,2

RMLCXX-MF-20 20 65,6

p.91

ASSEMBLED DMX cables

RDMX01 SF series

Standard configuration. Others configuration on request. This series are manufactured with DMX01SF cable and Amphenol connectors 5PIN. Available in different lengths. Applications: data transmission DMX protocol. Benefits: Robust construction - Low capacitance - H density braid shield - AWG 24 - Amphenol XLR with machined male pins - Hi flexibility.

Standard configuration

AVAILABLE LENGHT Code metres feet

RDMX01SF-MF-5 5 16,4

RDMX01SF-MF-10 10 32

RDMX01SF-MF-15 15 49,2

RDMX01SF-MF-20 20 65,6

Available also with: XLR 3 PIN

ASSEMBLED DMX cables

RDMX03 series

Standard configuration. Others configuration on request. This series are manufactured with DMX03 cable and Amphenol connectors 5 PIN . Available in different lengths. Applications: data transmission DMX protocol. Benefits: Robust construction - Low capacitance - H density braid shield + foil - AWG22 - Amphenol XLR with machined male pins - Hi flexibility

Standard configuration

AVAILABLE LENGHT Code metres feet

RDMX03-MF-5 5 16,4

RDMX03-MF-10 10 32

RDMX03 -MF-15 15 49,2

RDMX03-MF-20 20 65,6

Available also with: XLR 3 PIN

ASSEMBLED DMX&HYBRID cables

RPLC01 series

Standard configuration. Others configuration on request. This series are manufactured with RPLC01 SERIES cable with Amphenol connectors.5PIN - Powercom and Schuko Benefits: Robust construction - Power 3x 1.5mm- Data AWG22Amphenol XLR with machined male pins - Hi flexibility

Standard configuration

AVAILABLE LENGHT Code metres feet

RPLC01 -MF-5 5 16,4

RPLC01-MF-10 10 32

RPLC01-MF-15 15 49,2

RPLC01 -MF-20 20 65,6

Available also with: XLR 3 PIN www.referencelaboratory.com

p.92

ASSEMBLED SPEAKER cables

SP series

We use hi flexibile speaker cable with hi winding proprieties and hi bending cycle. SPEAKON/SPEAKON - Standard configuration: SP8= RPC21 (8X2.5) and NL8/NL8. SP4= RPC09 (4X2.5) and NL4/NL4.

AVAILABLE LENGTH Code metres feet

SP8/SP4 1 3,28

SP8/SP4 3 9,8

SP8/SP4 5 16,4

SP8/SP4 10 32,8

SP8/SP4 15 49,2

For code and model please follow price list - others length on request. SPEAKON/JACK - Standard configuration: RPC02 (2x2.5) and NL2/Speaker Jack RPP-S500

AVAILABLE LENGTH Code metres feet

SP7 1 3,28

SP7 3 9,8

SP7 5 16,4

SP7 10 32,8

SP7 15 49,2

For code and model please follow price list - others lengtht on request. JACK/JACK - Standard configuration: RPC 02 (2x2.5) and 2x Speaker jack RPP-S500

AVAILABLE LENGTH Code metres feet

SP6 1 3,28

SP6 3 9,8

SP6 5 16,4

SP6 10 32,8

SP6 15 49,2

For code and model please follow price list - others length on request.

We use RPCM cable for have hi flexible speaker cable with hi winding proprieties and hi bending cycle. Standard configuration. RPCM01 (2x3.3) + 2 x Speaker Jack RPP-S500

AVAILABLE LENGTH Code metres feet

RPCM01-TR/FU-JJ-3 3 9,8

RPCM01-TR/FU-JJ- 5 5 16,4

RPCM01-TR/FU-JJ-10 10 32,8

For code and model please follow price list - others length on request.

We use RPCM cable for have hi flexibile speaker cable with hi winding proprieties and hi bending cycle. Standard configuration. RPCM01 (2x3.3) + 1 NL2 + 1 x Speaker Jack RPP-S500

AVAILABLE LENGTH Code metres feet

RPCM01 TR/FU J-SP-3 1 9,8

RPCM01 TR/FU J-SP-5 5 16,4

For code and model please follow price list - others length on request. Available also SPEAKON/SPEAKON. www.referencelaboratory.com

RPCM01 TR/FU J-SP-10 10 32,8

p.93

ASSEMBLED SPEAKER cables for line array systems

Extremely flexible ideal for line array system - This speaker cables have hi strand copper for minimum power loss and maximum flexibility. This is also noticeable in longer cable lengths, the result is more powerful on low frequency and clear high range.

Recommended

by DV2 for Line array

SOCA/SOCA This series are available in different length use cable RPC32 (16x4mmq) and Reference 19 pin multipin connectors socapex compatible. Thanks at this cable, an unique cable is able drawing 8 or 16 speakers (like Adamson, JBL or V-Dosc/dV-Dosc) standard 10 - 15 and 25 metres. (different length on request)

SPIN SOCA M Spin soca M is the terminal at speakers Assembled with 19 male pin Reference - Neutrik speakon NL8 and RPC48 (8x4mmq)

SPIN SOCA F Spin soca F is Conjuntion rack/ SOCA panel Assembled with 19 female pin Reference - Neutrik speakon NL8 and RPC48 (8x4mmq).

LINK The link cable is for link two speaker together, use speaker cable model RPC31 (8x2.5mmq) and 2 NL8 speakon. Two length 0.80 cm and 1.20 cm as standard, on request any length.

www.referencelaboratory.com

p.94

ASSEMBLED MULTISTRAND SPEAKER cables

for line array systems

Extremely flexible ideal for line array system - This speaker cables have hi strand copper for minimum power loss and maximum flexibility. This is also noticeable in longer cable lengths, the result is more powerful on low frequency and clear high range.

Recommended

by DV2 for Line array

SOCA/SOCA This series are available in different length use cable RPC33 (16x4mmq) and Reference 19 pin multipin connectors socapex compatible. Thanks at this cable, an unique cable is able drawing 8 or 16 speakers (like Adamson, JBL or V-Dosc/dV-Dosc)) standard 10 - 15 and 25 metres. (different length on request)

SPIN SOCA M Spin soca M is the terminal at speakers Assembled with 19 male pin Reference - Neutrik speakon NL8 and RPC47 (8x4mmq)

SPIN SOCA F Spin soca F is Conjuntion rack/ SOCA panel Assembled with 19 female pin Reference - Neutrik speakon NL8 and RPC48 (8x4mmq).

LINK The link cable is for link two speaker together, use speaker cable model RPC21 (8x2.5mmq) and 2 NL8 speakon. Two length 0.80 cm and 1.20 cm as standard, on request any length.

www.referencelaboratory.com

p.95

ASSEMBLED SPEAKER cables for active loudspeaker

A variety range of cable for all active speaker.

XLR F/ Schuko - XLRM/ Powercon Mains 1.5mmq - cable mod. RPLC01 NPI Available also no NPI version Other configuration on request.

AVAILABLE LENGHT Code metres feet

RPLC01 MF-S/NAC3 -5 5 16,4

RPLC01 MF-S/NAC3 -10 RPLC01 MF-S/NAC3 -15 RPLC01 MF-S/NAC3 -20 10 15 20 32 49 65,6

XLR F/ Schuko P- XLR M/Powercon. Mains 2.5mmq - cable mod. RPLC06 NPI Available also no NPI version (RPLC10) Other configuration on request.

AVAILABLE LENGHT Code metres feet

RPLC06 MF-S/NAC3 -5 5 16,4

RPLC06 MF-S/NAC3 -10 RPLC06 MF-S/NAC3 -15 RPLC06 MF-S/NAC3 -20 10 15 20 32 49 65,6

XLR F/CEI 309 P-XLRM/ CEI309 Mains 2.5mmq - cable mod. RPLC11 NPI Other configuration on request.

AVAILABLE LENGHT Code metres feet

RPLC11 MF-309MF -5 5 16,4

RPLC11 MF-309MF -10 10 32

RPLC11 MF-309 MF -15 15 49

RPLC11 MF-309MF -20 20 65,6

RDQC series EP

Berklee Clinic at Arena Sferisterio (MC) 1995

CABLE DRUMS

p.98

CABLE DRUM Reference Drum Quick Care Serie The Reference Cable Drum is a “new line” and it consist of two series: a) “Standard” with three models as RDC-01s, RDC-01, RDC-01XL b) “Quick Care” with three models as RDQC-04, RDQC-05, RDQC-06 Both series have the same structure with strong steel frame, black finish, both series use the same type of Drum. The Reference “Quick Care” drum is unique on the studio market, range and category because its concept: 1) Is to carry easier and secure just by one people trought a combined system by reels and retractile handTM 2) To become a stage box (See boxes accessories). The Reference “Quick Care” drum and standard Cable drum are designed to support the following qty of cable, considering each models:

CABLE CAPACITY models RDC01 S RDC01 RDC01XL RDCQC04 RDCQC05 RDCQC06

internal dimension out diam core diam

290 290 290 450 450 450

80 80 80 190 190 200

width

80 120 310 150 300 500

RMC01 RPC13 RSC04 RSC08 RSC12 RSC16 RSC25 RSC33 RSC40 RSC48 RCC01 ø 6,9 75 116 302 308 616

RDC01 S Dim.: L= 18cm W= 33cm H= 34cm Weight= 5.5Kg

RDQC04 Dim.: L= 36cm W= 63cm H= 54cm Weight= 22Kg

www.referencelaboratory.com

ø 7,0 74 115 299 326 699

ø 9,0 ø 12,60 ø 15,50 ø 15,80 ø 21,50 ø 23,00 ø 25,20 ø 28,00 ø 16,00 41 24 16 16 16 67 37 23 23 23 177 100 66 63 35 25 25 16 64 193 93 64 56 29 24 21 16 56 399 195 135 112 64 53 46 34 112 665 331 228 193 114 86 81 58 193

RDC01 Dim.: L= 22cm W= 33cm H= 34cm Weight= 6Kg

RDQC05 Dim.: L= 52cm W= 63cm H= 54cm Weight=22,5Kg

RDC01 XL Dim.: L= 40cm W= 33cm H= 34cm Weight= 8Kg

RDQC06 Dim.: L= 71cm W= 63cm H= 54cm Weight= 23,5Kg

p.99

BOX FOR CABLE DRUM

Step by step... Reference Quick Care Drum... gets dressed and becomes a “Stage Box”!! Program Box and Pannel for RDC series ❶









❶ ❷ ❸ ❹ ❺ ❻ ❼

REB-15164 REP-JACK2 REP-XLRF REP-JACK RDC01-12M/4F-RSC16-20MT complet set: 12 IN/4 OUT + 20 mt RSC 16 REP-O REP-XLR3 REP-XLR

RSC/D01





Program Box and Pannel for RDQC series ❶ ❷ ❸ ❹ ❺ ❻ ❼ ❽







*



*

11

Round pannel with 5 xlr holes Round pannel with multipin hole 10

11

*

** Stage/Monitor/House signal distribution system components: N° 1

Main stage box with cable drum; connections panel and 50 meters of 48 channels multicore mod. RDQC 06 w/REPXLR

N° 5

Secondary stage boxes with cable Drum RDC-01 w/REPXLR; connections panel and 20 meters of 8 channels multicore mod. RSC series

N° 1

40 channels snake RSC series for monitor mixer connection

N° 1

40 In/8

40

*

Ch. 33 - 40

9

9 Round blind pannel 10









REB-26319 REP-O-BL2664 REP XLR 1/8 REP XLR 9/16 REP XLR 17/24 REP XLR 24/32 REP Stage Box REP SubM/SM

48

Wiring Set up

Out

snake RSC series for FOH mixer connection

using the Cable Drum “Quick Care” series

www.referencelaboratory.com

p.100

CABLE + CABLE DRUM = CUSTOM SOLUTION REFERENCE CABLE + REFERENCE CABLE DRUM= CUSTOM SOLUTION This section intend give you an idea of our custom production. Any solution is customized on request – for details please your local Reference Laboratory agent or distributor.

ROBC 01 polyurethane Model: ROBC01 (1 Video BNC + 1 Intercom XLR + 2 Audio Pin RCA) Application: Audio- Video recording from camera to OBVan

Model: RGB05/AC (5 Video + AC Power) Application: VIDEO Projector supply - all in one cable!

Model: RFBC01 (2 Video BNC +2 Audio XLR + I Intercom XLR + Power) Application: Fisher boom

Model: RCBM01 (2 Video BNC +1 Audio XLR + Power) Application: Video application for live events recording / playback in conference rooms

www.referencelaboratory.com

p.101

CUSTOM SOLUTION

Model: RSC4 (4 pair balanced audio cable) Application: Master out; delay line; service's lines

Model: RCOM01 (4 wire Intercom extension cable) Application: Intercom 2 ch with thru box for extension length - Multi split intercom

Model RVC59D (2 video RG59 + 2 Balanced audio Application: Digital console transmission; Video + audio; Video + intercom; composite video + balanced audio as service's lines

Model: LIGHTNex (RCL-M20-SF 7X4MMQ) Application: Light power supply; dischange lighting power supplies

www.referencelaboratory.com

p.102

CUSTOM SOLUTION Some example of audio distribution

Model: 48CHs + 8 Return (1 RDQC06 + 5 RDC 01 for stage distribution + monitor and master fan out) Application: Stage distribution with passive monitor splitter

Model: 24CHs + 8 Return Application: Stage distribution with return ch's for small bands / rental companies

Model: 12CHs + 4 Return Application: Stage distribution with return ch's for small bands

www.referencelaboratory.com

p.103

REFERENCE EMPTY BOXES AND PANELS

An example of floor box assembled with 8 XLR F/4XLR MALE plus multipin.

RESB01S Floor box 1/2 U RESB 1/2 S Floor box 1/4 U

RESB02 Floor box 2U

RMP-2 Panels 2 U Blind

RESB01 Floor box 1U

RMP-1 Panel 1 U Blind RPD16 Panel 1 U with 16 holes for XLR RPD8 Panel 1 U with 8 holes for XLR RPD12 Panel 1 U with 12 holes for XLR

RMP 85-150 Panel 2 U with 2 holes for multipin 85-150

Panel for Adamson Y - Axys series

RMP 37-54 Panel 2 U with 4 holes for multipin 37-54 RMP 19-25 Panel 2 U with 6 holes for multipin 19-25

www.referencelaboratory.com

p.104

ACCESSORIES FOR CABLE DRUMS A definitive soft (strongest) bag to reduce mechanical inconvenient on live application’s fan out and cable thanks at our soft covers and cable drums.

RSBS 6

RSBS16

RSBS33

RSBS48

FAN OUT UP TO: 6 XLR

16 XLR

33 XLR

48 XLR

A dedicated soft cover with identified window for better management and to protect cable, connectors and cable identification.

COVER FOR CABLE DRUM For RDC series RSC/D01-S

RSC/D01

RSC/D01-XL

For RDQC series For RDQC 04 model RSC/QD04 For RDQC 05 model RSC/QD05 For RDQC 06 model RSC/QD06

A dedicated soft cover with identified window for better management and to protect cable, connectors and drum.

www.referencelaboratory.com

p.105

DISPLAY STAND “ F a i d a t e ” and PENGUIN STAND

LARGE

SMALL

support up to 20 cable reels and 8 sticks for displayed assembled cables.

support up to 12 cable reels and 5 sticks for displayed assembled cables.

PENGUIN

Width (cm) Depth center (cm) Height (cm) LARGE SMALL PENGUIN

100 65,5 58

44 44 65

Weight (kg/lbs)

196 196 176

MICROSONIC MUSIC

67/30,5 50/22,8 37/15

Sticks* 8 pcs 5 pcs 5 pcs

Universal monitor EPIC series

Why choose Microsonic Music? At Microsonic Music we have over half a century’s experience in the design and production of products for the human ear. The company is widely recognized as one of the world’s leading full service earmold laboratories. Why chose Microsonic’s monitors? There are several benefits to Microsonic’s monitors for both musicians and personal listeners. For the musician, you have the freedom to move around. Your monitors will go wherever you go, allowing you to add passion to your performance. Therefore, when used correctly, Microsonic’s monitors are better for your ears and for your long term career as a musician. Personal listeners can also benefit from the sound isolation provided by Microsonic’s monitors. The reduction of ambient sounds means you will also be able to reduce the volume level in your ear, protecting your hearing. The EPIC™ Series Our universal monitors, the EPIC™ Series, offers the closest experience to a custom made monitor. Using our patent-pending swivel nozzle in conjunction with an extremely comfortable flanged ear tip positioned deep in the ear canal, it offers a fit like no other in the industry. EPIC™ Universal JC Designed to provide superb fidelity for listening environments where transparency is the utmost priority Frequency Response: 20Hz - 16kHz Impedance: 10 ohms at 1kHz Sensitivity: 104 dB at 1kHz EPIC™ Universal X Designed to provide enhanced bass to maximize the total sound experience Rap artists, bass players, drummers, DJs, electric guitarists, personal listeners Frequency Response: 20Hz - 16kHz Impedance: 16 ohms at 500Hz Sensitivity: 118 dB at 1kHz www.referencelaboratory.com

p.106

REFERENCE D i - B o x

R.DI.B series

Passive DI BOX 10:1 Frequency Response 30-50.000 Hz. Input Impedance 10k ohm. Attenuator 2 positions Phone Input, XLR OUTPUT

Fully Galvanical Isolated Passive DI Box 2 CH , RATIO10:1 Frequency Response : 20 -50.000Hz. Input: two input at 10KOhm for each channels (phone RCA and Jack) with Pad. switch. (020dB) Output : XLR

RDI B 01

Frequency

Frequency response dB @ RL = 10 K Ω, Uin = 0dBV

20 Hz 50 Hz 100 Hz 400 Hz 1 kHz 5 kHz 10 kHz 15 kHz 20 kHz 30 kHz 50 kHz 100 kHz

-0,32 -0,13 -0,05 -0,01 0 0,02 0,08 0,16 0,29 0,64 1,58 -8,03