Brass ball valves 60 series

12 downloads 18696 Views 403KB Size Report
3-way ball valves with surface conforms ... Symbol. Series. Type. Application. Materials. Max. Temperature. Thread body seats/ ... Pressure/temperature diagram.
®

Brass ball valves 60 series

®

G 1/8 to G 3 Rp 1/4 to Rp 2

Ideally suited for most industrial applications Easy installation, simple operation and maintenance free Full bore passage giving minimum flow resistance 3-way ball valves with surface conforms to ISO 5211 for rotary actuators

Technical data

Ordering information

Medium: Compressed air, water, inert gases and any other fluid compatible with the valve materials Port sizes: Mini G 1/8 to G 1/2 Standard G 1/8 to G 3 3-way G 1/4 to G 3/4 Gas approved Rp 1/4 to Rp 2 Operating pressure: See individual details Operating temperature: Refer to table over the page

To order quote the appropriate product numbers from the tables on the following pages.

Materials Body: nickel plated brass to UNI 5705-65 Seats: virgin PTFE Seals: virgin PTFE, FKM or nitrile Ball: chromium plated brass Handle with PVC grip: zinc plated steel (plastic handle on mini ball range)

5/09

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

N/en 5.10.040.01

Brass ball valves, 60 series

®

®

General information Symbol

Series 2

Type

Application

6011

Mini

General, light duty

Materials body Brass

seats/seals PTFE & nitrile ‘O’ring

Max. pressure (bar) 10

Temperature range -10 to +90°C

Thread standards ISO 228/1

6018

Lockable exhausting

General, with exhaust

Brass

PTFE

13,6

4 to 60°C

ISO 228/1

6021

Standard

General purpose

Brass

PTFE & viton ‘O’ring

10 to 45

-20 to +150°C

ISO 228/1

6021

Three way

General diverting

Brass

PTFE & nitrile ‘O’ring

16 to 25

-15 to +150°C

ISO 228/1

6021

Exhausting

General with exhaust

Brass

PTFE

40 to 64

-20 to +100°C

ISO 228/1

6041

Standard

Commercial gas and general

Brass

PTFE

63 5 for gas

-15 to +120°C ISO 7/1 Rp -20 to +60°C for gas

10

12 1 2

10

12 3

1 2 10

12 1 2

10

12 3

1 2 10

12 3

1 2 10

12 1

6011: Light duty in-line brass ball valves suitable for a wide variety of low pressure industrial uses. 6018: Medium duty in-line brass exhausting ball valves. Venting action & lockout design adds safety feature to valve. 6021: Medium duty in-line brass ball valves for most applications. Available as a standard valve, a three way diverting valve or with a downstream exhaust option.

6041: Designed and certified to comply with the EN331 European norm covering gas ball valves.

6011 series Miniball G

Model 601112118 601112128 601112138 601112148

øE

A

D

Reduced bore, female/female

B

H

A G1/8 G1/4 G3/8 G1/2

B 18 18 21 25

C 36 36 41 48

D 22 22 24 30

ØE 5,5 5,5 8,0 10,0

G 19 19 19 22

H 9 9 9 10

19 19 21 25

Weight (kg) 0,078 0,071 0,086 0,137

C

G

A

A1

D

øE

Reduced bore, male/female

H

H1 B

Model 601112218 601112228 601112238 601112248

A G1/8A G1/4A G3/8A G1/2A

A1 G1/8 G1/4 G3/8 G1/2

B 20 20 21 25

C 37 37 41 48

D 22 22 24 30

ØE 5,5 5,5 8,0 10,0

G 19 19 19 22

H 9 9 9 11

H1 9 9 9 11

19 19 21 25

Weight (kg) 0,063 0,061 0,083 1,300

C

N/en 5.10.040.02

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

5/09

Brass ball valves, 60 series

®

®

6021 series Standard ball valve Full bore, female/female

G

Model

øF

A øE

D

602112128 602112138 602112148 602112168 602112188 6021121A8 6021121B8 6021121C8 6021121D8 6021121E8

H C

G

D

602112228 602112238 602112248 602112268 602112288 6021122A8

øF

A1

øE

A

C

D

Ø E

Ø F

G

H

G1/4 G3/8 G1/2 G3/4 G1 G1 1/4 G1 1/2 G2 G2 1/2 G3

48 49 60 69 83 96 106 129 159 182

36 36 40 47 51 63 69 83 99 110

8 10 15 20 25 32 40 50 65 80

23 24 30 38 46 58 70 86 111 135

85 85 85 105 105 130 130 165 248 248

12 12 15 16,3 19,1 21,4 22 25,7 30,2 33,3

Weight (kg) 18 21 25 31 38 47 54 66 85 100

0,116 0,130 0,182 0,315 0,496 0,880 1,300 2,170 3,770 5,840

Full bore, male/female Model

A

Max. pressure (bar) 45 40 35 30 25 20 20 16 16 10

C

Max. pressure (bar) 45 40 35 30 25 20

A

A1

C

D

ØE

ØF G

G1/4A G3/8A G1/2A G3/4A G1A G1 1/4A

G1/4 G3/8 G1/2 G3/4 G1 G1 1/4

50 54 65 75 86 99

36 36 40 47 51 63

8 10 15 20 25 32

23 24 30 38 46 58

85 85 85 105 105 130

Weight (kg) 18 21 25 31 38 47

0,113 0,140 0,200 0,350 0,530 0,927

For T handle valves, substitute 2 for 1 at 4th digit.

Pressure/temperature diagram bar 50

1/ 4 3/ 8 1/ 2 3/ 4

40 30

1 11/4 - 11/2 2 3

20 10

–20

0

+25

+50

+75

+100

+125

+150 °C

6021 Exhausting ball valve G

Full bore, female/female

H C

A

C

D

ØE

ØF

G

G1/4 G3/8 G1/2 G3/4 G1 G1 1/4

52 54 69 77 89 103

61 61 64 76 80 98

8 10 15 20 25 32

29 29 36 45 54 65

100 100 100 120 120 150

Weight (kg) 22 22 27 33 40 50

0,245 0,245 0,370 0,635 0,890 1,550

1 1

5/09

Max. pressure (bar) 602113128EX 64 602113138EX 64 602113148EX 50 602113168EX 50 602113188EX 50 6021131A8EX 40

For T handle valves, substitute 2 for 1 at 4th digit.

øF

A øE

D

Model

Exhaust

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

N/en 5.10.040.03

Brass ball valves, 60 series

®

®

6021 3-way ball valve conforms to ISO 5211 115 1

38

25

J

A

øE

D

K

S

9

5,5

9

H C øF

M7

ø 36

1

Handle and fitting kit supplied lose

2

Two screws for dead stops (90° increments)

2

Full bore Model

602114428 602114438 602114448 602114468

Max. pressure (bar) 25 25 25 16

N/en 5.10.040.04

A

C

D

ØE

ØF

H

J

G1/4 G3/8 G1/2 G3/4

52 52 64 74

60 60 62 43

10 10 15 20

28 28 34,5 43

11 11,5 15 16

26 26 33,5 39,5

Flow

22 22 27 32

Kv 1,5 1,8 3,9 7,9

Weight (kg) 0,34 0,28 0,41 0,60

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

5/09

Brass ball valves, 60 series

®

®

6041 Gas approved ball valve Pressure/temperature diagram

G

bar

D

60 50

øF

A øE

40 30 20 10

C

–15

0

+25

+50

+75

+100

°C

Full bore Model

604112128 604112138 604112148 604112168 604112188 6041121A8 6041121B8 6041121C8

Max. pressure Fluid Gas (bar) (bar) 63 5 63 5 63 5 63 5 63 5 63 5 63 5 63 5

A

B

C

D

ØE

ØF

G

Rp1/4 Rp3/8 Rp1/2 Rp3/4 Rp1 Rp1 1/4 Rp1 1/2 Rp2

41 41 44 53 57 70 76 92

49 49,5 61 69,5 84 98 108 130

35 36 44 52 56 63 69 83

8 10 15 20 25 32 40 50

23 24 32 40 48 60 72,5 88

85 85 85 105 105 130 130 165

Weight

18 21 26 32 39 48 55 68

(kg) 0,116 0,125 0,210 0,356 0,585 0,950 1,400 2,450

6018 Lockable exhausting ball valve G

Full bore, female/female Model

601812128 601812138 601812148 601812168 601812188

Max. pressure (bar) 13,6 13,6 13,6 13,6 13,6

A

B

ØE

C

G

G1/4 G3/8 G1/2 G3/4 G1

45 45 50 57 61

8 9 14 19 24

44 44 58 64 81

93 93 93 114 114

Weight (kg) 20 20 24 30 40

0,170 0,160 0,240 0,370 0,620

Lever lockable only in closed position. Standard handle accepts Ø 7 mm shackle. Test specification differs from standard. Please consult our Technical Service for futher details.

øE

A

D

7,5

1 C

1

5/09

Exhaust

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

N/en 5.10.040.05

Brass ball valves, 60 series

®

®

Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under ‘Technical Data’. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes.

N/en 5.10.040.06

The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

5/09