CEI. Comitato Elettrotecnico Italiano. CSA. Canadian Standard Association ....
CEI, PVC-single cores according to Italian Standard . ... FROR CEI 20 – 22 II .
Cables according to Overseas standards
F
â
Cables according to Overseas standards The installation of cables and wires according to overseas standards are getting more and important for the machine and plant industries. HELUKABELâ knows this problem from his customers and delivers since long time single core and multicore cables according to the following standards. Due to our extensive stock capacity, we are in a position to cover your requirements quick and correctly.
F
Please enquire to our sales department. UL AWM MTW CEI CSA SEV USASI CNOMO
Underwriters Laboratories Inc. Appliance Wiring Material Machine Tool Wire Comitato Elettrotecnico Italiano Canadian Standard Association Schweizerischer Elektrotechnischer Verein USA Standard Institute Comite´ De Normalisation Des Moyens De Production
â
F
Contents and Index Description/standards F
Type
Page
Cables according to overseas standards
UL-CSA, PVC-single cores . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL-CSA, PVC-single cores . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HAR-UL-CSA, PVC-single cores . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HAR-UL-CSA-AWM-MTW, PVC-single cores . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL, PVC + Nylon-single cores . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL-CSA, Polyolefin-single cores . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL-CSA, Polyolefin-single cores . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL, PVC control cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL, PVC control cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL, PVC control cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL, PVC control cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL, PVC control cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL, PVC control cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL-CSA, Rubber control cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CEI, PVC-single cores according to Italian Standard . . . . . . . . . . . . . . . . . . . . CEI, Control cable according to Italian Standard . . . . . . . . . . . . . . . . . . . . . . . . . C.N.O.M.O. Control cable according to French Standard. . . . . . . . . . . . . . . PVC-Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PVC-Power Cable screened. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UL-AWM 1007, CSA-AWM, 300 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F 1 UL-AWM/MTW 1015, CSA-AWM, 600 V . . . . . . . . . . . . . . . . . . . . . F 2 THREENORM HAR-UL-CSA, 300 V to 750 V . . . . . . . . . . . . . . . F 3 FIVENORM HAR-UL-CSA-AWM-MTW . . . . . . . . . . . . . . . . . . . . . . . . . . F 4 THHN/THWN, 600 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F 5 HELUTHERM 145, 300 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F 6 HELUTHERM 145, 600 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F 7 Style 2464 / 300 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F 8 Style 2516 / 600 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F 9 Style 2464 / 300 V, Cu-screened. . . . . . . . . . . . . . . . . . . . . . . . . . . F 10 Style 2516 / 600 V, Cu-screened. . . . . . . . . . . . . . . . . . . . . . . . . . . F 11 Style 2464 / 300 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F 12 Style 2464 / 300 V, Cu-screened. . . . . . . . . . . . . . . . . . . . . . . . . . . F 13 SJO / 300 V, SO / 600 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F 14 CEI 20 – 22 II. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F 15 FROR CEI 20 – 22 II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F 16 N05V V5-F accord. to standard NFC 32 – 206 . . . . . . . . . F 17 JZ-604 TC TRAY CABLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F 18 – F 19 JZ-604-YCY TRAY CABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F 20 – F 21
Works photo: HELUKABELâ
â
HELUKABEL is not only selling cables and wires for all fields of communication techniques, but they are also using exhibitions as a medium of communication all over the world. The active and regular participation on exhibitions is an essential part of our Marketing-Mix.
F
Exhibitions are seen as an information and Communication Centre which allow HELUKABELâ to be at the forefront of the competitive market. Because national and international exhibition participations are an answer for your cable enquiries. â
UL-Style 1007, CSA TR 64
300 V
PVC-single cores, UL-CSA approved, 808 C
Technical data
Cable structure*
Application
PVC-insulated jumper wire to UL-Style and CSA-AWM * UL-Style 1007 * CSA-AWM I A/B or TR 64 – Temperature range flexible – 58 C bis +808 C fixed installation –308 C bis +808 C CSA-AWM I A/B or TR 64 +908 C – Nominal voltage 300 V – Test voltage 2000 V – Test voltage (Spark test) AWG 26 – 20 = 4 kV AWG 10 – 18 = 5 kV – Bending radius once ca. 5 x cable 1 multiple ca. 10 x cable 1
– Stranded copper conductor, tinned to UL-Std. 785 section G – PVC-core insulation according to UL-Std. 1587 class 43 Tab. 50.182, heat and damp resistant – PVC self-extinguishing and flame retardant, test method to UL V W-1/CSA FT1
For the internal wiring of switchbords, electrical equipment, e. g. households, radio or televisions and control desks. Connecting wires in machines laid in protective tubes and flexible pipes and also for motors and transformators.
– The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers Standards = Underwriters Laboratories Inc. UL (USA) CSA = Canadian Standards Association (Canada)
AWM: Appliance Wiring Material For internal wirings for electrical equipment and control apparatus e. g. electronic assembly components. Resistance Conditionally resistant to – Oils – Solvents – Acids – Lyes
F
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Part No.
AWGno.*)
crosssection ca. mm2
Outer 1 ca. mm
Cop kg / km
Weight ca. kg / km
635 620 621 622 623 624 636 637 638
26 24 22 20 18 16 14 12 10
0,13 0,21 0,33 0,52 0,82 1,32 2,08 3,31 5,26
1,3 1,4 1,6 1,9 2,2 2,5 3,0 3,9 4,1
1,6 2,3 3,4 5,3 8,2 13,0 20,0 33,0 51,6
3,2 4,3 6,0 8,5 12,5 18,5 29,0 40,0 61,0
Preis DM / 100 m Cu 300, –
Style 1569, +808 C/+908 C/+1058 C on request.
*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15. " You can find further information regarding UL/CSA-Cables on pages T 71 – T 77. Please complete the above part-no. for the colour required, using the following table: 00 green 01 black 02 blue 03 brown 04 red 05 white 06 grey 07 violet 08 yellow 09 orange 10 transparent 11 pink 12 beige 13 green-yellow
* Due to design the constructional alternations may the possible. ** Plain copper conductor on request PVC cables will be changed to lead free PVC successively. For further single cores see the following pages: – for PVC, see pages D 1 – D 10. – for PUR, see page G 32. – for rubber, see pages G 31, O 15. – halogen-free, see pages G 23 – G 24, E 5, E 15 – E 16, E 24 – E 26. – heat-resistant, see pages E 5 – E 6, E 10 – E 11, E 13 – E 16, E 21, E 23 – E 25. – vehicle cables, see pages K 1 – K 4. Further sizes and jacket colours available on request. Type THHN, TEW-AWM see page F 5. Further types on request..
â
F1
UL-Style 1015
600 V PVC-Single Cores, UL/CSA approved
Technical data
Cable structure*
Application
– PVC-insulated jumper wire as per UL AWM Style 1015/MTW and CSA-AWM/TEW * as per UL-Style 1015 and CSA-TEW – Temperature range flexible – 58 C to +1058 C fixed installation –308 C to +1058 C – Temperature at conductor max. UL and CSA: +1058 C – Nominal voltage 600 V – Test voltage (Spark test) AWG 24 : 4 kV AWG 22 and 20 : 5 kV AWG 18 to 10 : 6 kV ^ AWG 8 : 7,5 kV
– Stranded copper conductor, tinned or plain**, AWG-sizes as per table below – PVC-core insulation according to UL-Standard 1581, class 43 and CSAC22.2 No. 210 UL V W-1 and CSA FT1, heat and damp resistant – PVC self-extinguishing and flame retardant, test method to UL V W-1
For the internal wiring of switchbords, electrical equipment, e. g. households, radio or televisions and control desks. Connecting wires in machines laid in predective tubes and flexible pipes and also for motors and transformators.
* *
UL-type AWM + MTW CSA-type AWM + TEW
1058 C 600 V 1058 C 600 V
– Bending radius once ca. 5 x cable 1 multiple ca. 10 x cable 1
– The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers Standards = Underwriters Laboratories Inc. UL (USA) CSA = Canadian Standards Association (Canada)
UL bzw. CSA: AWM: Appliance Wiring Material For internal wirings for electrical equipment and control apparatus e. g. electronic assembly components. UL-MTW: Machine Tool-Wires CSA-TEW: Equipment/Lead Wires MTW: Machine Tool Wire For the electronical installation of machine tools and the relative control Resistance Conditionally resistant to – Oils – Solvents – Acids – Lyes
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
UL/CSA AWM = 1058C, UL MTW, CSA TEW = 1058 C, 600 V Part No.
AWGno.*)
as per UL-AWM MTW
CSA AWM TEW
crosssection ca. mm2
601 602 603 604 605 606 607 608
24 22 20 18 16 14 12 10
1015/MTW 1015/MTW 1015/MTW 1015/MTW 1015/MTW 1015/MTW 1015/MTW 1015/MTW
AWM/TEW AWM/TEW AWM/TEW AWM/TEW AWM/TEW AWM/TEW AWM/TEW AWM/TEW
0,21 0,33 0,52 0,81 1,31 2,08 3,32 5,26
2,2 2,4 2,5 2,8 3,0 3,6 4,2 4,8
2,3 3,2 5,0 7,9 12,6 20,7 33,0 51,6
8 10 12 16 22 31 45 65
609
8
1015/MTW
AWM/TEW
8,35
6,4
80,6
110
610 611 612 613
6 4 3 2
1015/MTW 1015/MTW 1015/MTW 1015/MTW
AWM/TEW AWM/TEW AWM/TEW AWM/TEW
13,29 21,14 26,65 33,61
8,2 9,3 9,5 11,8
125,0 201,0 253,0 317,0
175 260 340 380
614 615 616 617 618
1 1/0 2/0 3/0 4/0
1015/MTW 1015/MTW 1015/MTW 1015/MTW 1015/MTW
AWM/TEW AWM/TEW AWM/TEW AWM/TEW AWM/TEW
42,38 53,47 67,40 84,97 107,17
14,0 15,0 16,0 18,5 20,2
399,0 500,0 631,0 792,0 996,0
500 615 750 900 1070
62501 62601 62701 62801 62901
250 kcmil 300 kcmil 350 kcmil 400 kcmil 500 kcmil
1015/MTW 1015/MTW 1015/MTW 1015/MTW 1015/MTW
127 152 178 203 254
" You can find further information regarding UL/CSA-Cables on pages T 71 – T 77. Type THHN, TEW-AWM see page F 5. Please complete the above part no. for the colour required, using the following table: 00 green 06 grey 12 beige 01 black 07 violet 13 green-yellow 02 blue 08 yellow 14 blue/white 03 brown 09 orange 15 dark blue 04 red 10 transparent 05 white 11 pink
F2
Outer 1 ca. mm
Cop kg / km
Weight ca. kg / km
Preis DM / 100 m Cu 300, –
19,6 1178,0 1280 20,9 1410,0 1518 22,2 1645,0 1756 24,5 1902,0 2002 25,8 2345,0 2475 * Due to design the constructional alternations may be possible. ** Plain copper conductor on request (cross-section in metric dimensions). PVC cables will be changed to lead free PVC successively. For further single cores see the following pages: – for PVC, see pages D 1 – D 10. – for PUR, see page G 32. – for rubber, see pages G 31, O 15. – halogen-free, see pages G 23 – G 24, E 5, E 15 – E 16, E 24 – E 26. – heat-resistant, see pages E 5 – E 6, E 10 – E 11, E 13 – E 16, E 21, E 23 – E 25. – vehicle cables, see pages K 1 – K 4. Further sizes and jacket colours available on request. *) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15.
â
â
HELUKABEL THREENORM
HAR-UL-CSA PVC-Single cores, UL-Style 1011 and CSA 600 V
Technical data
Cable structure
Application
– PVC-single cores according to DIN VDE 0281 part 3 and HD 21.3 S3 UL-Style 1011 and CSA, CSAAWM I/A/B 2 – Temperature range ) * H05 V-K/H07 V-K flexing + 58 C to +708 C fixed installation –108 C to +708 C * UL/CSA +808 C – Nominal voltage H05 V-K U0/U 300/500 V (# 1 mm2) H07 V-K U0/U 450/750 V ($ 1,5 mm2) UL/CSA 600 V AC – Test voltage H05 V-K/H07 V-K 2000 V – Spark Test AWG 20 : 5 kV .AWG 20 : 6 kV – Insulation resistance min. 20 MOhm x km – Minimum bending radius for permanent bending ca. 10 – 15 x core 1
1 – Bare copper fine wire ) stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, HD 383 and IEC 60228 cl. 5 UL-Subject 758 Section G resp. ASTM B 174 – PVC core insulation TI1 to DIN VDE 0281 part 1 and UL-Std. 1581, class 43, CSA-C 22.2 No. 210 Tab. 12 class H – Core colours to DIN VDE 0293 – PVC self-extinguishing and flame retardant according to DIN VDE 0482 part 265-2-1/EN 50265-2-1/IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B),UL-V W1 CSA FT1
Three norms approved connecting jumper wire primarily designed for exportes, used in machine tools. This wire is used for internal wiring of switchboards and electrical equipment. The approbation of HAR-UL-CSA AWM make possible an economical storekeeping and simplification of parts list.
F
– The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers **) Note AWG equivalet values – see page T 15.
1
) Tinned conductor on request
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Type crosssec.
Outer 1
mm
Cop. weight kg/km
ca. RAL H05 V-K/mm2 Part No. 0,5/AWG 20 2,5 Part No. 0,75/AWG 19 2,65 Part No. 1/AWG 18 2,8 H07 V-K/mm2 Part No. 1,5/AWG 16 3,05 Part No. 2,5/AWG 14 3,6 Part No. 4/AWG 12 4,1 Part No. 6/AWG 10 4,8 Part No. 10/AWG 8 6,4 Part No. 16/AWG 6 8,1 Part No. 25/AWG 4 9,6 Part No. 35/AWG 2 10,8 Part No. 50/AWG 1 13,6 Part No. 70/AWG 2/0 15,2 Part No. 95/AWG 3/0 16,8 Part No. 120/AWG 4/0 19,5 Part No. 150/300 kcmil 22,2
blackwhite
gn-ye
blue
brown
red
white
grey
viol.
yellow
pink
green
trans.
dark blue
orange
other colours
twintone
9005
6018/ 1021
5015
8003
3000
1013
7000
4005
1021
3015
6018
–
5010
2003
–
–
63815
63816
63817
63818
63819
63820
63821
63822
63823
63824
63825
63826
63827
63828
63829
63830
63831
63832
63833
63834
63835
63836
63837
63838
63839
63840
63841
63842
63843
63844
63845
63846
63847
63848
63849
63850
63851
63852
63853
63854
63855
63856
63857
63858
63859
63860
63861
63862
63863
63864
63865
63866
63867
63868
63869
63870
63871
63872
63873
63874
63875
63876
63877
63878
63879
63880
63881
63882
63883
63884
63885
63886
63887
63888
63889
63890
63891
63892
63893
63894
63895
63896
63897
63898
63899
63900
63901
63902
63903
63904
63905
63906
63907
63908
63909
63910
63911
63912
63913
63914
63915
63916
63917
63918
63919
63920
63921
63922
63923
63924
63925
63926
63927
63928
63929
63930
63931
63932
63933
63934
63935
63936
63937
63938
63939
63940
63941
63942
63943
63944
63945
63946
63947
63948
63949
63950
63951
63952
63953
63954
63955
63956
63957
63958
63959
63960
63961
63962
63963
63964
63965
63966
63967
63968
63969
63970
63971
63972
63973
63974
63975
63976
63977
63978
63979
63980
63981
63982
63983
63984
63985
63986
63987
63988
63989
63990
4,8 7,2 9,6
14,4 24,0 38,0 58,0 96,0 154,0 240,0 336,0 63991
63992
63993
63994
63995
63996
63997
63998
63999
64000
64001
64002
64003
64004
64005
64006
64007
64008
64009
64010
64011
64012
64013
64014
64015
64016
64017
64018
64019
64020
64021
64022
64023
64024
64025
64026
64027
64028
64029
64030
64031
64032
64033
64034
64035
64036
64037
64038
64039
64040
64041
64042
64043
64044
64045
64046
64047
64048
64049
64050
64051
64052
64053
64054
64055
64056
64057
64058
64059
64060
64061
64062
64063
64064
64065
64066
64067
64068
64069
64070
480,0 672,0 912,0 1152,0 1440,0
PVC cables will be changed to lead free PVC successively. 2
) The cross-sections 0,5, 0,75 and 1,0 mm2 are according to H05 V-K, the cross-sections 1,5 up to 120 mm2 according to H07 V-K.
â
F3
â
HELUKABEL FIVENORM
HAR-UL-CSA-AWM-MTW PVC-Single cores, UL-Style 1015/UL-Standard 1063, 600 V 1058 C
Technical data
Cable structure
Application
– PVC-single cores according to DIN VDE 0281 part 3 and HD 21.3 S3, UL-Std. 1063, UL-Style 1015 and CSA-TEW and CSA-AWM I/A/B 2 – Temperature range ) * H05 V2-K/H07 V-K flexing + 58 C to + 908 C fixed installation –108 C to +1058 C * UL/CSA +1058 C – Nominal voltage H05 V2-K U0/U 300/500 V (# 1 mm2) H07 V2-K U0/U 450/750 V ($ 1,5 mm2) UL/CSA 600 V AC, 750 V DC – Test voltage H05 V2-K/H07 V2-K 2000 V – Spark Test AWG 20 : 5 kV .AWG 20 : 6 kV – Insulation resistance min. 20 MOhm x km – Minimum bending radius for permanent bending ca. 10 – 15 x core 1
1 – Bare copper fine wire ) stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, HD 383 and IEC 60228 cl. 5 and UL-Subject 758 Section G – PVC core insulation TI3 to DIN VDE 0281 part 1 and UL-Std. 1581, class 43, CSA-C 22.2 No. 210 Tab. 12 class H – Core colours to DIN VDE 0293 – PVC self-extinguishing and flame retardant according to DIN VDE 0482 part 265-2-1/EN 50265-2-1/IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1
Five norms approved connecting jumper wire primarily designed for exportes, used in machine tools. This wire is used for internal wiring of switchboards and electrical equipment. The approbation of HAR, UL-AWM, UL-MTW, CSA-AWM, CSA-Equipment-wire make possible an economical storekeeping and simplification of parts list.
– The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers **) Note AWG equivalet values – see page T 15. PVC cables will be changed to lead free PVC successively.
1
) Tinned conductor on request
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Type crosssec.
Outer 1
mm
Cop. weight kg/km
ca. RAL H05 V2-K/mm2 Part No. 0,5/AWG 20 2,5 Part No. 0,75/AWG 19 2,65 Part No. 1/AWG 18 2,8 H07 V2-K/mm2 Part No. 1,5/AWG 16 3,05 Part No. 2,5/AWG 14 3,6 Part No. 4/AWG 12 4,1 Part No. 6/AWG 10 4,8 Part No. 10/AWG 8 6,4 Part No. 16/AWG 6 8,1 Part No. 25/AWG 4 9,6 Part No. 35/AWG 2 10,8 H07 V-K/mm2 Part No. 50/AWG 1 13,6 Part No. 70/AWG 2/0 15,2 Part No. 95/AWG 3/0 16,8 Part No. 120/AWG 4/0 19,5 Part No. 150/300 kcmil 22,2
blackwhite
gn-ye
blue
brown
red
white
grey
viol.
yellow
pink
green
trans.
dark blue
orange
other colours
twintone
9005
6018/ 1021
5015
8003
3000
1013
7000
4005
1021
3015
6018
–
5010
2003
–
–
64075
64076
64077
64078
64079
64080
64081
64082
64083
64084
64085
64086
64087
64088
64089
64090
64091
64092
64093
64094
64095
64096
64097
64098
64099
64100
64101
64102
64103
64104
64105
64106
64107
64108
64109
64110
64111
64112
64113
64114
64115
64116
64117
64118
64119
64120
64121
64122
64123
64124
64125
64126
64127
64128
64129
64130
64131
64132
64133
64134
64135
64136
64137
64138
64139
64140
64141
64142
64143
64144
64145
64146
64147
64148
64149
64150
64151
64152
64153
64154
64155
64156
64157
64158
64159
64160
64161
64162
64163
64164
64165
64166
64167
64168
64169
64170
64171
64172
64173
64174
64175
64176
64177
64178
64179
64180
64181
64182
64183
64184
64185
64186
64187
64188
64189
64190
64191
64192
64193
64194
64195
64196
64197
64198
64199
64200
64201
64202
64203
64204
64205
64206
64207
64208
64209
64210
64211
64212
64213
64214
64215
64216
64217
64218
64219
64220
64221
64222
64223
64224
64225
64226
64227
64228
64229
64230
64231
64232
64233
64234
64235
64236
64237
64238
64239
64240
64241
64242
64243
64244
64245
64246
64247
64248
64249
64250
64251
64252
64253
64254
64255
64256
64257
64258
64259
64260
64261
64262
64263
64264
64265
64266
64267
64268
64269
64270
64271
64272
64273
64274
64275
64276
64277
64278
64279
64280
64281
64282
64283
64284
64285
64286
64287
64288
64289
64290
64291
64292
64293
64294
64295
64296
64297
64298
64299
64300
64301
64302
64303
64304
64305
64306
64307
64308
64309
64310
64311
64312
64313
64314
64315
64316
64317
64318
64319
64320
64321
64322
64323
64324
64325
64326
64327
64228
64329
64330
4,8 7,2 9,6
14,4 24,0 38,0 58,0 96,0 154,0 240,0 336,0
480,0 672,0 912,0 1152,0 1440,0
2
) The cross-sections 0,5, 0,75 and 1,0 mm2 are according to H05 V-K, the cross-sections 1,5 up to 35 mm2 according to H07 V-K, the cross-sections 435 mm2 are identified as H07V-K. Cross-sections up to 35 mm2 is according to DIN VDE 0281 part 5. Due to this cross-sections 435 mm2 is the type H07VK, but with an increased heat-resistant PVCcompound.
F4
â
THHN/THWN
908 C, 600 V UL listed PVC + Nylon-Single Cores
Technical data
Cable structure
Application
– PVC+Nylon insulated single cores as per UL-Styles and NEC standard – Temperature range as per Styles * THHN: 908 C dry – NEC standard * THWN: 758 C wet – NEC standard * AWM: UL-Styles 1316 to 1321 1058 C dry 808 C in oil * AWM: UL-Styles 1452, 1453 908 C dry 808 C in oil 1000 V * MTW: UL-Styles 1408 to 1414 908 C dry 808 C in oil 600 V – Nominal voltage 600 V – Test voltage (Spark test) AWG 14 to AWG 10 : 7,5 kV AWG 8 to AWG 2/0 : 10 kV AWG 3/0 to AWG 4/0 : 12,5 kV kcmil 250 to kcmil 500 : 15 kV kcmil 600 to kcmil 1000 : 17,5 kV
– Bare copper conductor, AWG-sizes as per given table below and ASTM B-3 and ASTM B-8 – Core insulation of PVC+Nylon-outer sheath – Cores colour coded, colour identification see below – Surface of jacket printed with markings: * 14 to 1000 MCM THHN (stranded) – (size) AWG TYPE MTW OR THHN OR THWN 600 V OR GASOLINE AND OIL RESISTANT II (UL) OR AWM E-51554 * 14 to 10 AWG THHN (solid) – (size) AWG TYPE THHN OR THWN 600 V OR GASOLINE AND OIL RESISTANT II (UL) OR AWM
As flexible connecting cable in machines, switch and distribution cabinets, cable assemblies and for fixed indoor installation, in tubes and in cable conduits.
Resistant against – Oils – Gasoline – Water – Acids – Ozone – Lyes – Sunlight – Abrasion
AWM: Appliance Wiring Material For internal wrings for electrical equipment and control apparatus e. g. radio and televisions, electronic assembly component MTW: Machine Tool Wire For the electronical installation of machine tools and the relative control THW: Thermoplastic PVC-insulated building wire, Heat resistant 758 C, for Wet and dry locations, flame retardant. THHN: Thermoplastic PVC-insulated building wire, Nylon jacketed, 908 C 600 V, for dry and damp locations. Normen = Underwriters Laboratories Inc. UL (USA)
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
PVC+Nylon-Single Cores, UL Listed Type THHN/THWN (908C) 600 V Part No.
AWGno.*)
crosssection mm2
conductor make-up AWGsize
n x wire 1
conductor 1 ca. mm
Wall-thickness (guiding value) PVCNyloninsulation jacket mm mm
Outer 1 ca. mm
Cop. weight kg / km
Weight ca. kg / km
DM / 100 m Cu 300, –
6320 6321 6322 6323 6324 6325
14 12 10 8 6 4
2,08 3,32 5,26 8,35 13,39 21,14
19/0,0147 19/0,0185 19/0,0234 19/0,0295 19/0,0378 19/0,0469
19 x 0,38 19 x 0,48 19 x 0,60 19 x 0,75 19 x 0,96 19 x 1,19
1,88 2,35 2,97 3,66 4,78 5,92
0,38 0,38 0,51 0,76 0,76 1,02
0,102 0,102 0,102 0,127 0,127 0,152
2,95 3,43 4,29 5,49 6,60 8,41
20,7 33,0 51,6 80,6 125,0 201,0
25 37 60 95 143 229
6326 6327 6328 6329 6330 6331 6332
3 2 1 1/0 2/0 3/0 4/0
26,65 33,61 42,38 53,47 67,40 84,97 107,17
19/0,053 19/0,0591 19/0,0664 19/0,0745 19/0,0837 19/0,094 19/0,1055
19 x 1,336 19 x 1,50 19 x 1,686 19 x 1,89 19 x 2,126 19 x 2,387 19 x 2,68
6,65 7,47 8,4 9,4 10,6 11,9 13,4
1,02 1,02 1,27 1,27 1,27 1,27 1,27
0,152 0,152 0,178 0,178 0,178 0,178 0,178
9,14 10,01 11,43 12,45 13,72 14,99 16,51
253,0 317,0 399,0 500,0 631,0 792,0 996,0
282 349 449 557 691 861 1069
63331 63341 63351 63361 63371 63381 63391 63401
250 kcmil 300 kcmil 350 kcmil 400 kcmil 500 kcmil 600 kcmil 750 kcmil 1000 kcmil
127 152 178 203 254 304 380 507
37/0,0822 37/0,0900 37/0,0973 37/0,104 37/0,1162 61/0,0992 61/0,1109 61/0,1280
37 x 2,088 37 x 2,286 37 x 2,47 37 x 2,7 37 x 2,95 61 x 2,52 61 x 2,82 61 x 3,25
14,6 16,0 17,3 18,9 20,7 22,7 25,3 29,3
1,52 1,52 1,52 1,52 1,52 1,78 1,79 1,78
0,203 0,203 0,203 0,203 0,203 0,229 0,229 0,229
18,29 19,56 21,08 22,35 24,13 26,75 29,36 33,27
1178,0 1410,0 1645,0 1902,0 2345,0 2920,0 3658,0 4858,0
1277 1515 1753 1998 2466 3000 3713 4796
1 kcmil = 1000 circ. mils = 0,5067 mm2. " You can find further information regarding UL/CSA-Cables on pages T 71 – T 77. Further types on request. Please complete the above part 0 green 5 1 black 6 2 blue 7 3 brown 8 4 red 9
no. for the colour required, using the following code: white grey yellow orange pink
Preis
*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15. For further single cores see the following pages: – for PVC, see pages D 1 – D 10. – for PUR, see page G 32. – for rubber, see pages G 31, O 15. – halogen-free, see pages G 23 – G 24, E 5, E 15 – E 16, E 24 – E 26. – heat-resistant, see pages E 5 – E 6, E 10 – E 11, E 13 – E 16, E 21, E 23 – E 25. – vehicle cables, see pages K 1 – K 4. Further sizes and jacket colours available on request.
â
F5
F
â
HELUTHERM 145
UL/CSA approved, 300 V Single cores flexible, electron beam cross-linked, halogen-free
Technical data
Cable structure
Application
– Halogen-free single cores with increased heat resistance according to UL Style 3266 CSA CL 1252 – Temperature range flexing –358 C to +1208 C fixed installation –558 C to +1458 C in short circuit +2508 C – Nominal voltage U0/U 300/300 V – Test voltage 3500 V – Minimum bending radius approx. 4 x cable 1
– Tinned Cu wires, according to AWGsizes Conductor make-up: AWG 24 to AWG 14 19-wires AWG 12 65-wires AWG 10 105-wires – Core insulation of polyolefin-copolymer, electron beam cross-linked, flame retardant, halogen-free – Core colours see table below
These temperature resistant single-core cables are used for the internal wiring of lighting fixtures, heaters, electrical machinery, switching systems and distributors in equipment and plant and machinery, suitable for installation on, in and beneath plaster, in closed installation ducts, as well as for traffic systems and outdoor applications. These cables are not approved for direct routing on racks, gutters or tanks. For a protected installation, these cables may be used at a nominal voltage of up to 1000 V alternating current or a direct current up to 750 V when earthed. The maximum operating d.c. voltage used in rail vehicles shall not exceed 900 V when earthed. These halogen-free single core cables are characterised by their amazingly hight long-time resistance to temperature and feature among the leading halogen-free. Flame resistant products in the world. These single core cables singnificantly contribute to safety and the environment.
Tests – Flame test to DIN VDE 0482 part 266-2/ HD 405.3, BS 4066 part 3/EN 50266-2/ IEC 60332-3 (equivalent DIN VDE 0472 part 804 test method C) – Corrosiveness of combustion gases according to DIN VDE 0482 part 267/ EN 50267-2-2/IEC 60754-2 (equivalent DIN VDE 0472 part 813) – Halogen-free according to DIN VDE 0482 part 267/EN 50267-2-1/IEC 60754-1 (equivalent DIN VDE 0472 part 815) – Smoke density to VDE 0482 part 268-1 and 2, test method C, IEC 61034-1/ 61034-2, HD 606 and BS 7622 part 1 and 2 (DIN VDE 0472 part 816) – The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers – Caloric load values see page T 69
Advantages – Halogen-free, no liberation of corrosive or toxic vapours, in that way this helps saving valuable time when trying to evacuate a building in a diciplined manner and prevents unnecessary loss of life. – Lower propagation of fire – Low development of smoke and fumes – Good abrasion and notch resistance – Good resistance to oils and weathering – Resistant to UV radiation and ozone – Resistant to soldering temperatures – Thermal class B – These single-core cables are resistant to melting, even when in contact with a soldering iron at temperatures of between 3008 C and 3808 C, because of the electron-beam cross-linking for the insulation material. – Due to the high temperature profile the cross-section of conductor can under certain circumstances be reduced, hereby enabling a saving in space requirement and weight.
– Power ratings table see page T 27 = The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Part No. Crosssec. mm2
Part No. AWG 24 Part No. AWG 22 Part No. AWG 20 Part No. AWG 18 Part No. AWG 16 Part No. AWG 14 Part No. AWG 12 Part No. AWG 10
Outer 1 ca. mm
Cop. weight kg / km
Weight ca. kg / km
1,5
2,3
4
1,6
3,2
6
1,9
5,0
9
2,1
7,9
12
2,4
12,6
16
2,9
20,7
27
3,3
33,0
36
4,1
51,6
58
Preis DM%m Cu 300,gn/ye
Preis DM%m Cu 300,black
Preis DM%m light blue
Preis DM%m Cu 300,brown
Preis DM%m Cu 300,red
Preis DM%m Cu 300,white
Preis DM%m Cu 300,grey
Preis DM%m Cu 300,violet
Preis DM%m Cu 300,yellow
Preis DM%m Cu 300,orange
Preis DM%m Cu 300,green
Preis DM%m Cu 300,pink
Preis DM%m Cu 300,beige
Preis DM%m Cu 300,twintone
61816
61817
61818
61819
61820
61821
61822
61823
61824
61825
61826
61827
61828
61829
61830
61831
61832
61833
61834
61835
61836
61837
61838
61839
61840
61841
61842
61843
61844
61845
61846
61847
61848
61849
61850
61851
61852
61853
61854
61855
61856
61857
61858
61859
61860
61861
61862
61863
61864
61865
61866
61867
61868
61869
61870
61871
61872
61873
61874
61875
61876
61877
61878
61879
61880
61881
61882
61883
61884
61885
61886
61887
61888
61889
61890
61891
61892
61893
61894
61895
61896
61897
61898
61899
61900
61901
61902
61903
61904
61905
61906
61907
61908
61909
61910
61911
61912
61913
61914
61915
61916
61917
61918
61919
61920
61921
61922
61923
61924
61925
61926
61927
*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15. For further single cores see the following pages: – for PVC, see pages D 1 – D 10. – for PUR, see page G 32. – for rubber, see pages G 33, O 15.
F6
– halogen-free, see pages G 23 – G 24, E 5, E 15 – E 16, E 24 – E 26. – heat-resistant, see pages E 5 – E 6, E 10 – E 11, E 13 – E 16, E 21, E 23 – E 25. – vehicle cables, see pages K 1 – K 4.
â
â
HELUTHERM 145
UL/CSA approved, 600 V Single cores flexible, electron beam cross-linked, halogen-free
Technical data
Cable structure
Application
– Halogen-free single cores with increased heat resistance according to UL Style 3271, CSA CL 1251 – Temperature range flexing –358 C to +1208 C fixed installation –558 C to +1458 C in short circuit +2508 C – Nominal voltage U 600 V – Test voltage 3500 V – Minimum bending radius approx. 4 x cable 1
– Tinned Cu wires, according to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC 60228 cl. 5 – Core insulation of polyolefin-copolymer, electron beam cross-linked, flame retardant, halogen-free – Core colours see table below
These temperature resistant single-core cables are used for the internal wiring of lighting fixtures, heaters, electrical machinery, switching systems and distributors in equipment and plant and machinery, suitable for installation on, in and beneath plaster, in closed installation ducts, as well as for traffic systems and outdoor applications. These cables are not approved for direct routing on racks, gutters or tanks. For a protected installation, these cables may be used at a nominal voltage of up to 1000 V alternating current or a direct current up to 750 V when earthed. The maximum operating d.c. voltage used in rail vehicles shall not exceed 900 V when earthed. These halogen-free single core cables are characterised by their amazingly hight long-time resistance to temperature and feature among the leading halogen-free. Flame resistant products in the world. These single core cables singnificantly contribute to safety and the environment.
Tests – Flame test to DIN VDE 0482 part 266-2/ HD 405.3, BS 4066 part 3/EN 50266-2/ IEC 60332-3 (equivalent DIN VDE 0472 part 804 test method C) – Corrosiveness of combustion gases according to DIN VDE 0482 part 267/ EN 50267-2-2/IEC 60754-2 (equivalent DIN VDE 0472 part 813) – Halogen-free according to DIN VDE 0482 part 267/EN 50267-2-1/IEC 60754-1 (equivalent DIN VDE 0472 part 815) – Smoke density to VDE 0482 part 268-1 and 2, test method C, IEC 61034-1/ 61034-2, HD 606 and BS 7622 part 1 and 2 (DIN VDE 0472 part 816) – The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers – Caloric load values see page T 69 – Power ratings table see page T 27
Advantages – Halogen-free, no liberation of corrosive or toxic vapours, in that way this helps saving valuable time when trying to evacuate a building in a diciplined manner and prevents unnecessary loss of life. – Lower propagation of fire – Low development of smoke and fumes – Good abrasion and notch resistance – Good resistance to oils and weathering – Resistant to UV radiation and ozone – Resistant to soldering temperatures – Thermal class B – These single-core cables are resistant to melting, even when in contact with a soldering iron at temperatures of between 3008 C and 3808 C, because of the electron-beam cross-linking for the insulation material. – Due to the high temperature profile the cross-section of conductor can under certain circumstances be reduced, hereby enabling a saving in space requirement and weight.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Part No. Crosssec. mm2
Outer 1 ca. mm
Cop. weight kg / km
Weight ca. kg / km
Part no. 0,25 2,3 2,4 7 Part no. 1 x 0,5 2,6 4,6 11 Part no. 1 x 0,75 2,8 7,2 14 Part no. 1 x 1,0 2,9 9,6 17 Part no. 1 x 1,5 3,2 14,4 22 Part no. 1 x 2,5 3,7 24,0 33 Part no. 1x4 4,2 38,4 53 Part no. 1x6 5,6 57,6 78 Part no. 1 x 10 7,5 96,0 136 Part no. 1 x 16 8,5 154,0 203 Part no. 1 x 25 10,4 240,0 300 Part no. 1 x 35 11,5 336,0 405 Part no. 1 x 50 14,4 480,0 580 For further single cores see the following pages: – for PVC, see pages D 1 – D 10. – for PUR, see page G 32.
Preis DM%m Cu 300,gn/ye
Preis DM%m Cu 300,black
Preis DM%m light blue
Preis DM%m Cu 300,brown
Preis DM%m Cu 300,red
Preis DM%m Cu 300,white
Preis DM%m Cu 300,grey
Preis DM%m Cu 300,violet
Preis DM%m Cu 300,yellow
Preis DM%m Cu 300,orange
Preis DM%m Cu 300,green
Preis DM%m Cu 300,pink
Preis DM%m Cu 300,beige
Preis DM%m Cu 300,twintone
59472
59473
59474
59475
59476
59477
59478
59479
59480
59481
59482
59483
59484
59485
59486
59487
59488
59489
59490
59491
59492
59493
59494
59495
59496
59497
59498
59499
59500
59501
59502
59503
59504
59505
59506
59507
59508
59509
59510
59511
59512
59513
59514
59515
59516
59517
59518
59519
59520
59521
59522
59523
59524
59525
59526
59527
59528
59529
59530
59531
59532
59533
59534
59535
59536
59537
59538
59539
59540
59541
59542
59543
59544
59545
59546
59547
59548
59549
59550
59551
59552
59553
59554
59555
59556
59557
59558
59559
59560
59561
59562
59563
59564
59565
59566
59567
59568
59569
59570
59571
59572
59573
59574
59575
59576
59577
59578
59579
59580
59581
59582
59583
59584
59585
59586
59587
59588
59589
59590
59591
59592
59593
59594
59595
59596
59597
59598
59599
59600
59601
59602
59603
59604
59605
59606
59607
59608
59609
59610
59611
59612
59613
59614
59615
59616
59617
59618
59619
59620
59621
59622
59623
59624
59625
59626
59627
59628
59629
59630
59631
59632
59633
59634
59635
59636
59637
59638
59639
59640
59641
59642
59643
59644
59645
59646
59647
59648
59649
59650
59651
59652
59653
– for rubber, see pages G 33, O 15. – halogen-free, see pages G 23 – G 24, E 5, E 15 – E 16, E 24 – E 26.
â
– heat-resistant, see pages E 5 – E 6, E 10 – E 11, E 13 – E 16, E 21, E 23 – E 25. – vehicle cables, see pages K 1 – K 4.
F7
F
Command Cable UL (LiYY)
approved Style 2464/300 V (808 C)
Technical data
Cable structure
Application
– Special PVC command cable, approved to UL-Style 2464, cores according AWG 26 – 20 to UL-Style 1061/1729 AWG 18 – 16 to UL-Style 1007/1569 – Temperature range –208 C to +808 C – Nominal voltage 300 V – Test voltage 1500 V – Breakdown voltage min. 3000 V – Minimum bending radius flexing approx. 15 x cable 1
– Tinned copper, fine wire conductors AWG 26 – 20 to ASTM-B 174-95 class J – M AWG 18 – 16 to ASTM-B 286 conductor make-up: to 0,14 mm2 = 7 x 0,162 mm 0,22 mm2 = 7 x 0,202 mm 0,34 mm2 = 7 x 0,254 mm 0,56 mm2 = 7 x 0,32 mm 0,82 mm2 = 19 x 0,235 mm 1,30 mm2 = 19 x 0,31 mm – Special PVC core insulation class 43, semirigid to UL-Std. 1581 table 50.182 and 50.183 – Colour coded to DIN 47100 – Cores stranded in layers with optimal lay-length – Special PVC outer jacket class 43 to UL-Std. 1581 table 50.182, colour * black * grey (preferred type for stock) – PVC flame retardant according to UL VW-1
Suitable for use as a command, measuring and control cable in tool making machinery conveyor system and production lines, in industrial plants and in air conditioning as well as in the steel producing industries. Resistance Conditionally resistant to – Oil – Solvents – Acids – Lyes – The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Part No.
No. strands
AWGno.*)
Size mm2
Outer 1 mm
83137 83138 83139 83140 83141 83142 83143 83144 83145 83146 83147
2 3 4 6 10 12 16 18 24 27 30
26 26 26 26 26 26 26 26 26 26 26
0,14 0,14 0,14 0,14 0,14 0,14 0,14 0,14 0,14 0,14 0,14
3,6 3,8 4,0 4,6 5,6 5,8 6,3 6,6 7,5 7,8 8,1
83153 83154 83155 83156 83157 83158 83159 83160 83161 83162 83163
2 3 4 6 10 12 16 18 24 27 30
24 24 24 24 24 24 24 24 24 24 24
0,22 0,22 0,22 0,22 0,22 0,22 0,22 0,22 0,22 0,22 0,22
83169 83170 83171 83172 83173 83174 83175 83176 83177 83178 83179
2 3 4 6 10 12 16 18 24 27 30
22 22 22 22 22 22 22 22 22 22 22
0,34 0,34 0,34 0,34 0,34 0,34 0,34 0,34 0,34 0,34 0,34
Weight ca. kg / km
Preis DM / 100 m Cu 300, –
Size mm2
Outer 1 mm
Weight ca. kg / km
Part No.
No. strands
AWGno.*)
13 15 18 25 38 46 56 62 82 97 110
83185 83186 83187 83188 83189 83190 83191 83192 83193 83194 83195
2 3 4 6 10 12 16 18 24 27 30
20 20 20 20 20 20 20 20 20 20 20
0,56 0,56 0,56 0,56 0,56 0,56 0,56 0,56 0,56 0,56 0,56
4,6 4,8 5,2 6,1 7,6 8,0 8,8 9,4 11,0 11,3 11,8
30 33 41 65 102 120 152 168 224 260 300
3,8 4,0 4,2 4,9 6,0 6,1 6,7 7,1 8,2 8,5 8,8
16 19 23 32 55 60 75 82 116 140 150
83201 83202 83203 83204 83205 83206 83207 83208 83209 83210 83211
2 3 4 6 10 12 16 18 24 27 30
18 18 18 18 18 18 18 18 18 18 18
0,82 0,82 0,82 0,82 0,82 0,82 0,82 0,82 0,82 0,82 0,82
6,1 6,4 6,9 8,1 10,4 10,9 12,2 13,0 15,2 15,8 16,3
50 62 72 100 180 182 240 270 370 400 470
4,2 4,3 4,6 5,5 6,8 7,0 7,8 8,3 9,6 10,0 10,2
25 30 45 60 80 105 130 140 190 207 225
83217 83218 83219 83220 83221 83222 83223 83224 83225 83226 83227
2 3 4 6 10 12 16 18 24 27 30
16 16 16 16 16 16 16 16 16 16 16
1,3 1,3 1,3 1,3 1,3 1,3 1,3 1,3 1,3 1,3 1,3
6,9 7,3 7,9 9,6 12,4 12,8 14,6 15,5 18,1 18,7 19,5
70 90 110 160 250 300 400 450 650 680 750
Preis DM / 100 m Cu 300, –
Continuation "
For further UL-approved control cables see the following pages: â – HELUKABEL JZ-602 page A 22 – A 23 â – HELUKABEL JZ-602-CY page A 26 – A 27 PVC cables will be changed to lead free PVC successively.
F8
*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15.
â
Command Cable UL (LiYY)
approved, Style 2516/600 V (1058 C)
Technical data
Cable structure
Application
– Special PVC command cable, approved to UL-Style 2516 – Temperature range –208 C to +1058 C – Nominal voltage 600 V – Test voltage 2000 V – Breakdown voltage min. 4000 V – Minimum bending radius flexing approx. 15 x cable 1
– Tinned copper, fine wire conductors to ASTM-B 174, class J – K conductor make-up: to 2,08 mm2 = 41 x 0,254 mm 3,20 mm2 = 65 x 0,254 mm Special PVC core insulation class 43 to – UL-Std. 1581 table 50.182 (1058 C) – Colour coded to DIN 47100 – Cores stranded in layers with optimal lay-length – Special PVC outer jacket class 43 to UL-Std. 1581 table 50.182 (1058 C), colour * black * grey (preferred type for stock) – PVC flame retardant according to UL VW-1
Suitable for use as a command, measuring and control cable in tool making machinery conveyor system and production lines, in industrial plants and in air conditioning as well as in the steel producing industries. Resistance Conditionally resistant to – Oil – Solvents – Acids – Lyes
F
– The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers = The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Part No.
No. strands
AWGno.*)
83233 83234 83235 83236 83237 83238 83239 83240 83241 83242 83243 83244
2 3 4 6 10 12 16 18 24 27 30 36
14 14 14 14 14 14 14 14 14 14 14 14
Size mm2 2,08 2,08 2,08 2,08 2,08 2,08 2,08 2,08 2,08 2,08 2,08 2,08
Outer 1 mm
Weight ca. kg / km
8,4 8,9 9,6 11,4 15,1 15,6 17,2 18,3 21,5 22,7 23,5 25,4
120 150 190 300 450 500 700 750 900 1100 1150 1800
For further UL-approved control cables see the following pages: â – HELUKABEL JZ-602 page A 22 – A 23 â – HELUKABEL JZ-602-CY page A 26 – A 27 PVC cables will be changed to lead free PVC successively.
Preis DM / 100 m Cu 300, –
Part No.
No. strands
AWGno.*)
83245 83246 83247 83248 83249 83250 83251 83252 83253
2 3 4 6 10 12 16 18 24
12 12 12 12 12 12 12 12 12
Size mm2 3,2 3,2 3,2 3,2 3,2 3,2 3,2 3,2 3,2
Outer 1 mm
Weight ca. kg / km
9,3 9,8 10,8 12,8 17,0 17,5 19,8 21,0 24,8
150 210 300 430 500 700 810 970 1200
Preis DM / 100 m Cu 300, –
*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15.
â
F9
Command Cable UL (LiYCY)
approved and screen Style 2464/300 V (808 C) EMC*-preferred type
Technical data
Cable structure
Application
– Special PVC command cable, approved to UL-Style 2464, cores according AWG 26 – 20 to UL-Style 1061/1729 AWG 18 – 16 to UL-Style 1007/1569 – Temperature range –208 C to +808 C – Nominal voltage 300 V – Test voltage 1500 V – Breakdown voltage min. 3000 V – Minimum bending radius flexing approx. 15 x cable 1 – Coupling resistance max. 250 Ohm/km
– Tinned copper, fine wire conductors AWG 26 – 20 to ASTM-B 174-95 class J – M AWG 18 – 16 to ASTM-B 286 conductor make-up: to 0,14 mm2 = 7 x 0,162 mm 0,22 mm2 = 7 x 0,202 mm 0,34 mm2 = 7 x 0,254 mm 0,56 mm2 = 7 x 0,32 mm 0,82 mm2 = 19 x 0,235 mm 1,30 mm2 = 19 x 0,31 mm – Special PVC core insulation class 43, semirigid to UL-Std. 1581 table 50.182 and 50.183 – Colour coded to DIN 47100 – Cores stranded in layers with optimal lay-length – Seperator-foil – Drain wire – Tinned copper wire braiding, approx. 85% coverage
This cable type is suitable for use as a flexible connector cable in the fields of electronics, control and command technology as well as for measuring, signal and impulse transfer. Quick and cost favourable connections through cutting and clamping technics.
– Special PVC outer jacket class 43 to UL-Std. 1581 table 50.182, colour * black * grey (preferred type for stock) – PVC flame retardant according to UL VW-1
Resistance Conditionally resistant to – Oil – Solvents – Acids – Lye *EMC = Electromagnetic compatibillity Note To optimise the EMC features we recommend a large round contact of the cooper braiding on both ends. – The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Part No.
No. strands
AWGno.*)
Size mm2
Outer 1 mm
83254 83255 83256 83257 83258 83259 83260 83261 83262 83263 83264
2 3 4 6 10 12 16 18 24 27 30
26 26 26 26 26 26 26 26 26 26 26
0,14 0,14 0,14 0,14 0,14 0,14 0,14 0,14 0,14 0,14 0,14
3,9 4,2 4,4 5,0 6,1 6,3 6,8 7,1 8,0 8,4 8,6
83270 83271 83272 83273 83274 83275 83276 83277 83278 83279 83280
2 3 4 6 10 12 16 18 24 27 30
24 24 24 24 24 24 24 24 24 24 24
0,22 0,22 0,22 0,22 0,22 0,22 0,22 0,22 0,22 0,22 0,22
83286 83287 83288 83289 83290 83291 83292 83293 83294 83295 83296
2 3 4 6 10 12 16 18 24 27 30
22 22 22 22 22 22 22 22 22 22 22
0,34 0,34 0,34 0,34 0,34 0,34 0,34 0,34 0,34 0,34 0,34
Weight ca. kg / km
Preis DM / 100 m Cu 300, –
Size mm2
Outer 1 mm
Weight ca. kg / km
Part No.
No. strands
AWGno.*)
20 25 28 30 50 53 60 70 100 105 110
83302 83303 83304 83305 83306 83307 83308 83309 83310 83311 83312
2 3 4 6 10 12 16 18 24 27 30
20 20 20 20 20 20 20 20 20 20 20
0,56 0,56 0,56 0,56 0,56 0,56 0,56 0,56 0,56 0,56 0,56
5,1 5,3 5,6 6,6 8,1 8,4 9,5 9,9 11,5 12,0 12,4
30 40 50 70 110 130 160 180 240 260 300
4,2 4,4 4,7 5,3 6,5 6,7 7,3 7,6 8,7 9,0 9,5
20 25 30 40 60 70 90 100 120 130 150
83318 83319 83320 83321 83322 83323 83324 83325 83326 83327 83328
2 3 4 6 10 12 16 18 24 27 30
18 18 18 18 18 18 18 18 18 18 18
0,82 0,82 0,82 0,82 0,82 0,82 0,82 0,82 0,82 0,82 0,82
6,5 6,8 7,4 8,8 10,9 11,2 12,9 13,5 15,6 15,9 16,6
60 75 90 125 180 220 290 300 450 470 490
4,6 4,8 5,1 6,0 7,3 7,5 8,2 8,7 9,9 10,4 10,9
40 50 60 80 130 140 160 170 220 250 280
83334 83335 83336 83337 83338 83339 83340 83341 83342 83343 83344
2 3 4 6 10 12 16 18 24 27 30
16 16 16 16 16 16 16 16 16 16 16
1,30 1,30 1,30 1,30 1,30 1,30 1,30 1,30 1,30 1,30 1,30
7,0 7,4 8,1 9,5 12,4 12,8 14,0 14,8 17,2 18,0 18,7
90 160 200 290 450 600 650 680 900 990 1050
Preis DM / 100 m Cu 300, –
Continuation " For further UL-approved control cables see the following pages: â – HELUKABEL JZ-602 page A 22 – A 23 â – HELUKABEL JZ-602-CY page A 26 – A 27
*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15.
PVC cables will be changed to lead free PVC successively.
F 10
â
Command Cable UL (LiYCY)
approved and screened Style 2516/600 V (1058 C) EMC*-preferred type
Technical data
Cable structure
Application
– Special PVC command cable, approved to UL-Style 2516 – cores according UL-Style 10012 – Temperature range –208 C to +1058 C – Nominal voltage 600 V – Test voltage 2000 V – Breakdown voltage min. 4000 V – Minimum bending radius flexing approx. 15 x cable 1 – Coupling resistance max. 250 Ohm/km
– Tinned copper, fine wire conductors to ASTM-B 174, class J – K conductor make-up: to 2,08 mm2 = 41 x 0,254 mm 3,20 mm2 = 65 x 0,254 mm Special PVC core insulation class 43 to – UL-Std. 1581 table 50.182 (1058 C) – Colour coded to DIN 47100 – Cores stranded in layers with optimal lay-length – Seperator-foil – Drain wire – Tinned copper wire braiding, approx. 85% coverage – Special PVC outer jacket class 43 to UL-Std. 1581 table 50.182 (1058 C), colour * black * grey (preferred type for stock) – PVC flame retardant according to UL VW-1
This cable type is suitable for use as a flexible connector cable in the fields of electronics, control and command technology as well as for measuring, signal and impulse transfer. Quick and cost favourable connections through cutting and clamping technics. Resistance Conditionally resistant to – Oil – Solvents – Acids – Lye *EMC = Electromagnetic compatibillity Note To optimise the EMC features we recommend a large round contact of the cooper braiding on both ends. – The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacqu
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Part No.
No. strands
AWGno.*)
83350 83351 83352 83353 83354 83355 83356 83357 83358 83359 83360
2 3 4 6 10 12 16 18 24 27 30
14 14 14 14 14 14 14 14 14 14 14
Size mm2 2,08 2,08 2,08 2,08 2,08 2,08 2,08 2,08 2,08 2,08 2,08
Outer 1 mm
Weight ca. kg / km
8,4 9,4 10,1 11,9 15,7 16,2 17,9 18,8 22,6 23,3 24,1
180 220 270 380 600 770 870 990 1300 1400 1610
For further UL-approved control cables see the following pages: â – HELUKABEL JZ-602 page A 22 – A 23 â – HELUKABEL JZ-602-CY page A 26 – A 27
Preis DM / 100 m Cu 300, –
Part No.
No. strands
AWGno.*)
83362 83363 83364 83365 83366 83367 83368 83369 83370
2 3 4 6 10 12 16 18 24
12 12 12 12 12 12 12 12 12
Size mm2 3,2 3,2 3,2 3,2 3,2 3,2 3,2 3,2 3,2
Outer 1 mm
Weight ca. kg / km
9,9 10,3 11,2 14,0 17,6 18,1 20,0 22,1 25,3
200 240 300 400 580 800 900 1000 1300
Preis DM / 100 m Cu 300, –
*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15.
PVC cables will be changed to lead free PVC successively.
â
F 11
F
Command Cable UL (LiYY-TP)
approved Style 2464/300 V (808 C)
Technical data
Cable structure
Application
– Special PVC command cable, approved to UL-Style 2464, cores according, UL-Style 1061/1729 – Temperature range flexing –108 C to +808 C fixed installation –208 C to +808 C – Nominal voltage 300 V – Test voltage 1500 V – Breakdown voltage min. 3000 V – Insulation resistance min. 100 MOhm x km – Minimum bending radius flexing approx. 15 x cable 1
– Tinned copper, fine wire conductors to ASTM-B 174-95 class J – M conductor make-up: to 0,14 mm2 = 7 x 0,162 mm 0,22 mm2 = 7 x 0,202 mm 0,34 mm2 = 7 x 0,254 mm 0,56 mm2 = 7 x 0,32 mm Special PVC core insulation class 43, – semirigid to UL-Std. 1581 table 50.182 and 50183 – Colour coded to DIN 47100 with colour repetition from pair no. 22 and above – Cores stranded in pains with optimal lay-length – Pains stranded in layers with optimal lay-length – Seperator-foil – Special PVC outer jacket class 43 to UL-Std. 1581 table 50.182, colour * black * grey (preferred type for stock) – PVC flame retardant according to UL VW-1
Twisted pair control cable for use in tool making machinery conveyor system and production lines, in industrial plants and in air conditioning as well as in the steel producing industries. Resistance Conditionally resistant to – Oil – Solvents – Acids – Lye
– The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Part. No.
No. pairs x cross-sec mm2
AWGno.*)
83904 83905 83906 83907 83908 83909 83910 83911 83912 83913 83914 83915 83916 83917 83918 83919 83920 83921
1 x 2 x 0,14 2 x 2 x 0,14 3 x 2 x 0,14 4 x 2 x 0,14 5 x 2 x 0,14 6 x 2 x 0,14 7 x 2 x 0,14 8 x 2 x 0,14 10 x 2 x 0,14 12 x 2 x 0,14 14 x 2 x 0,14 15 x 2 x 0,14 16 x 2 x 0,14 18 x 2 x 0,14 20 x 2 x 0,14 22 x 2 x 0,14 24 x 2 x 0,14 25 x 2 x 0,14
26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26
83922 83923 83924 83925 83926 83927 83928 83929 83930 83931 83932 83933 83934 83935 83936 83937 83938 83939
1 x 2 x 0,22 2 x 2 x 0,22 3 x 2 x 0,22 4 x 2 x 0,22 5 x 2 x 0,22 6 x 2 x 0,22 7 x 2 x 0,22 8 x 2 x 0,22 10 x 2 x 0,22 12 x 2 x 0,22 14 x 2 x 0,22 15 x 2 x 0,22 16 x 2 x 0,22 18 x 2 x 0,22 20 x 2 x 0,22 22 x 2 x 0,22 24 x 2 x 0,22 25 x 2 x 0,22
24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24
Outer 1 ca. mm
Weight ca. kg / km
Part. No.
No. pairs x cross-sec mm2
AWGno.*)
3,6 5,1 5,3 5,8 6,2 6,8 6,8 7,3 7,4 9,1 9,8 10,6 10,6 11,1 11,9 12,4 13,1 13,4
20 24 30 38 44 51 57 64 76 93 103 109 112 119 130 150 169 178
83940 83941 83942 83943 83944 83945 83946 83947 83948 83949 83950 83951 83952 83953 83954 83955 83956 83957
1 x 2 x 0,34 2 x 2 x 0,34 3 x 2 x 0,34 4 x 2 x 0,34 5 x 2 x 0,34 6 x 2 x 0,34 7 x 2 x 0,34 8 x 2 x 0,34 10 x 2 x 0,34 12 x 2 x 0,34 14 x 2 x 0,34 15 x 2 x 0,34 16 x 2 x 0,34 18 x 2 x 0,34 20 x 2 x 0,34 22 x 2 x 0,34 24 x 2 x 0,34 25 x 2 x 0,34
22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22
4,2 5,9 6,3 7,0 7,6 8,2 8,2 9,0 10,7 11,3 12,1 12,7 12,7 13,6 14,4 15,1 16,2 16,7
38 44 60 79 92 119 128 139 171 194 222 231 240 264 291 300 359 381
3,8 5,4 5,7 6,2 6,6 7,2 7,2 7,8 9,2 9,7 10,2 10,9 10,9 11,5 12,2 13,0 13,7 14,2
32 36 48 56 71 80 89 98 111 135 160 171 185 209 230 248 279 292
83958 83959 83960 83961 83962 83963 83964 83965 83966 83967 83968 83969 83970 83971 83972 83973 83974 83975
1 x 2 x 0,56 2 x 2 x 0,56 3 x 2 x 0,56 4 x 2 x 0,56 5 x 2 x 0,56 6 x 2 x 0,56 7 x 2 x 0,56 8 x 2 x 0,56 10 x 2 x 0,56 12 x 2 x 0,56 14 x 2 x 0,56 15 x 2 x 0,56 16 x 2 x 0,56 18 x 2 x 0,56 20 x 2 x 0,56 22 x 2 x 0,56 24 x 2 x 0,56 25 x 2 x 0,56
20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
4,6 6,5 7,1 7,8 8,6 9,6 9,6 12,1 12,5 13,1 13,8 14,7 14,7 15,7 16,7 17,2 18,6 19,2
60 80 94 104 130 151 174 262 298 302 327 370 402 480 551 621 703 721
*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15.
F 12
Outer 1 ca. mm
PVC cables will be changed to lead free PVC successively. Further jacket colours available on request.
â
Weight ca. kg / km
Command Cable UL (LiYCY-TP)
approved, Style 2464/300 V (808C), EMC*-preferred type, Cu-screened
Technical data
Cable structure
Application
– Special PVC command cable, approved to UL-Style 2464, cores according, UL-Style 1061/1729 – Temperature range flexing –108 C to +808 C fixed installation –208 C to +808 C – Nominal voltage 300 V – Test voltage 1500 V – Breakdown voltage min. 3000 V – Insulation resistance min. 100 MOhm x km – Minimum bending radius flexing approx. 20 x cable 1 – Coupling resistance max. 250 Ohm/km
– Tinned copper, fine wire conductors to ASTM-B 174-95 class J – M conductor make-up: to 0,14 mm2 = 7 x 0,162 mm 0,22 mm2 = 7 x 0,202 mm 0,34 mm2 = 7 x 0,254 mm 0,56 mm2 = 7 x 0,32 mm Special PVC core insulation class 43, – semirigid to UL-Std. 1581 table 50.182 and 50183 – Colour coded to DIN 47100 with colour repetition from pair no. 22 and above – Cores stranded in pains with optimal lay-length – Pains stranded in layers with optimal lay-length – Seperator-foil – Drain wire – Tinned copper wire braiding, approx. 85% coverage
Twisted pair control cable for use in tool making machinery conveyor system and production lines, in industrial plants and in air conditioning as well as in the steel producing industries.
– Special PVC outer jacket class 43 to UL-Std. 1581 table 50.182, colour * black * grey (preferred type for stock) – PVC flame retardant according to UL VW-1
Resistance Conditionally resistant to – Oils – Solvents – Acids – Lye *EMC = Electromagnetic compatibility Note To optimise the EMC features we recommend a large round contact of the copper braiding on both ends. – The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Part. No.
No. pairs x cross-sec mm2
AWGno.*)
83774 83775 83776 83777 83778 83779 83780 83781 83782 83783 83784 83785 83786 83787 83788 83789 83790 83791
1 x 2 x 0,14 2 x 2 x 0,14 3 x 2 x 0,14 4 x 2 x 0,14 5 x 2 x 0,14 6 x 2 x 0,14 7 x 2 x 0,14 8 x 2 x 0,14 10 x 2 x 0,14 12 x 2 x 0,14 14 x 2 x 0,14 15 x 2 x 0,14 16 x 2 x 0,14 18 x 2 x 0,14 20 x 2 x 0,14 22 x 2 x 0,14 24 x 2 x 0,14 25 x 2 x 0,14
26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26
83792 83793 83794 83795 83796 83797 83798 83799 83800 83801 83802 83803 83804 83805 83806 83807 83808 83809
1 x 2 x 0,22 2 x 2 x 0,22 3 x 2 x 0,22 4 x 2 x 0,22 5 x 2 x 0,22 6 x 2 x 0,22 7 x 2 x 0,22 8 x 2 x 0,22 10 x 2 x 0,22 12 x 2 x 0,22 14 x 2 x 0,22 15 x 2 x 0,22 16 x 2 x 0,22 18 x 2 x 0,22 20 x 2 x 0,22 22 x 2 x 0,22 24 x 2 x 0,22 25 x 2 x 0,22
24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24
Outer 1 ca. mm
Weight ca. kg / km
Part. No.
No. pairs x cross-sec mm2
AWGno.*)
Outer 1 ca. mm
4,0 5,6 5,8 6,3 6,7 7,3 7,3 7,8 9,1 9,8 10,5 11,1 11,1 11,8 12,4 13,1 13,6 15,1
32 39 47 55 68 86 92 97 111 141 150 154 155 170 183 207 228 239
83810 83811 83812 83813 83814 83815 83816 83817 83818 83819 83820 83821 83822 83823 83824 83825 83826 83827
1 x 2 x 0,34 2 x 2 x 0,34 3 x 2 x 0,34 4 x 2 x 0,34 5 x 2 x 0,34 6 x 2 x 0,34 7 x 2 x 0,34 8 x 2 x 0,34 10 x 2 x 0,34 12 x 2 x 0,34 14 x 2 x 0,34 15 x 2 x 0,34 16 x 2 x 0,34 18 x 2 x 0,34 20 x 2 x 0,34 22 x 2 x 0,34 24 x 2 x 0,34 25 x 2 x 0,34
22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22
4,6 6,4 6,9 7,5 8,1 8,8 8,8 9,7 11,5 12,0 12,6 13,4 13,4 14,4 15,0 15,9 17,0 17,3
58 65 78 88 110 126 140 148 184 210 241 245 251 275 300 320 371 402
4,2 5,9 6,2 6,7 7,2 7,7 7,7 8,4 9,9 10,2 10,9 11,4 11,4 12,2 12,7 13,5 14,5 14,8
46 53 65 79 98 114 121 129 152 189 213 225 227 238 270 300 321 340
83828 83829 83830 83831 83832 83833 83834 83835 83836 83837 83838 83839 83840 83841 83842 83843 83844 83845
1 x 2 x 0,56 2 x 2 x 0,56 3 x 2 x 0,56 4 x 2 x 0,56 5 x 2 x 0,56 6 x 2 x 0,56 7 x 2 x 0,56 8 x 2 x 0,56 10 x 2 x 0,56 12 x 2 x 0,56 14 x 2 x 0,56 15 x 2 x 0,56 16 x 2 x 0,56 18 x 2 x 0,56 20 x 2 x 0,56 22 x 2 x 0,56 24 x 2 x 0,56 25 x 2 x 0,56
20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
5,0 7,0 7,6 8,3 9,1 10,1 10,1 12,7 13,2 13,6 14,4 15,5 15,5 16,3 17,1 18,0 19,4 19,8
70 89 102 119 140 162 198 272 307 318 342 381 417 494 570 643 724 740
Weight ca. kg / km
*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15. PVC cables will be changed to lead free PVC successively. Further jacket colours available on request.
â
F 13
F
Rubber/Neoprene Control Cable UL-CSA approved; Types SJO and SO
Technical data
Cable structure
Application
– UL+CSA approved rubber/neoprene flexible cables – Temperature range SJO and SO –408 C to +908 C – Nominal voltage 300 volt for SJO – Nominal voltage 600 volt for SO – Approvals UL Subject 62 CSA-C22.2-49
– Plain copper conductors to ASTM B-174 – Core insulation of synthetic rubber, EPDM – Cores colour coded – Cores stranded in layers with optimal lay-length – Hemp or cotton tape – Outer jacket neoprene (oil resistant) – Jacket colour black
For use as a feeder cable under rough conditions in motors and machine construction, at shipyards, in steel production and in farming. Supply lengths are on original reels of 76 m or 152 m or on drums of 305 m lengths. Resistant – Oil – Wetness – UV-radiation
Colour code 2 cores = black, white 3 cores = black, white, green 4 cores = black, white, green, red = The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Nominal voltage 300 volt, type SJO (908 C) Part No. type SJO
Neoprene sheath type SJO
AWG no.*) + Cores
Rating A
Stranding
Outer 1 ca. mm
63010 63011 63012 63013 63014 63015 63016 63017 63018
SJO-18/2 SJO-18/3 SJO-18/4 SJO-16/2 SJO-16/3 SJO-16/4 SJO-14/2 SJO-14/3 SJO-14/4
18/2 18/3 18/4 16/2 16/3 16/4 14/2 14/3 14/4
7 7 7 10 10 10 15 15 15
16 x 0,3 16 x 0,3 16 x 0,3 26 x 0,3 26 x 0,3 26 x 0,3 41 x 0,3 41 x 0,3 41 x 0,3
7,8 8,4 9,2 8,3 9,0 10,0 9,4 10,0 10,7
Rating A
Stranding
Outer 1 ca. mm
Weight ca. kg / km
Preis DM / 100 m Cu inkl.
65 80 95 130 148 180 195 225 288
Nominal voltage 600 volt, type SO (908C) Part No. type SO
Neoprene sheath type SO
AWG no.*) + Cores
63034 63035 63036 63037 63038 63039 63040 63041 63042 63043 63044 63045 63046 63047 63048
SO-18/2 SO-18/3 SO-18/4 SO-16/2 SO-16/3 SO-16/4 SO-14/2 SO-14/3 SO-14/4 SO-12/2 SO-12/3 SO-12/4 SO-10/2 SO-10/3 SO-10/4
18/2 18/3 18/4 16/2 16/3 16/4 14/2 14/3 14/4 12/2 12/3 12/4 10/2 10/3 10/4
7 7 7 10 10 10 15 15 15 20 20 20 25 25 25
16 x 0,3 16 x 0,3 16 x 0,3 26 x 0,3 26 x 0,3 26 x 0,3 41 x 0,3 41 x 0,3 41 x 0,3 65 x 0,3 65 x 0,3 65 x 0,3 105 x 0,3 105 x 0,3 105 x 0,3
10,0 10,4 11,0 10,4 11,0 12,3 13,5 14,3 15,3 15,3 16,2 18,9 16,4 17,5 19,0
*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15. Further types also available: PVC control cables SJT, SJTO, ST, STO. Example: SJO-18/2 AWG 18
No. of cores
Further dimensions and versions available on request.
F 14
Weight ca. kg / km
n x AWG
â
70 86 110 140 155 200 200 235 300 280 310 330 305 325 365
Preis DM / 100 m Cu inkl.
PVC-Single Cores
to CEI 20-22 II
Technical data
Cable structure
Application
– PVC-Single Cores – As per Italian standard CEI 20 – 22 II – Temperature range flexing – 58 C to +808 C fixed installation –308 C to +808 C – Nominal voltage U0/U 450/750 V = 1 mm2 and above U0/U 300/500 V = 0,5 and 0,75 mm2 U0/U 300/300 V = 0,35 mm2 – Test voltage 2500 V – Minimum bending radius 4 – 6 x cable 1
– Bare fine wire stranded copper conductor to CEI 20 – 29 cl. 5 – PVC-core insulation R 2 up to CEI 20 II, cap. VI cl. 3 – Low smoke – PVC self-extinguishing and flame retardant
As hook up wire, control cabinet building, in cable assembly manufacturing as well as in electronic applications.
– The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
Resistant to – Oil – Solvents – Acids – Lyes
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Type cross-sec.
Cop. weight kg / km
Outer 1 ca. mm
Weight ca. kg / km
Colour (per RAL) 05 V-K Part No. 0,35 mm2 Part No. 0,50 mm2 Part No. 0,75 mm2 07 V-K Part No. 1,0 mm2 Part No. 1,5 mm2 Part No. 2,5 mm2 Part No. 4,0 mm2 Part No. 6,0 mm2 Part No. 10,0 mm2 Part No. 16,0 mm2 Part No. 25,0 mm2 Part No. 35,0 mm2 Part No. 50,0 mm2 Part No. 70,0 mm2 Part No. 95,0 mm2 Part No. 120,0 mm2 Part No. 150,0 mm2
2,5
1,5
3,6
4,8
2,6
6,0
7,2
2,8
10,0
9,6
3,2
16,0
14,4
3,5
21,0
24,0
4,2
32,0
38,0
4,6
48,0
58,0
6,3
69,0
96,0
7,6
117,0
154,0
8,8
180,0
240,0
11,0
266,0
336,0
12,5
366,0
480,0
14,5
515,0
672,0
16,5
741,0
912,0
18,5
950,0
1152,0
21,0
1230,0
1440,0
23,0
1500,0
Preis DM%m Cu 300,black
Preis DM%m Cu 300,gn/ye
Preis DM%m Cu 300,blue
Preis DM%m Cu 300,brown
Preis DM%m Cu 300,red
Preis DM%m Cu 300,white
Preis DM%m Cu 300,dk.blue
Preis DM%m Cu 300,other colours
9005
6018/1021
5015
8003
3000
1013
5010
29600
29601
29602
29603
29604
29605
29606
29607
29608
29609
29610
29611
29612
29613
29614
29615
29616
29617
29618
29619
29620
29621
29622
29623
29624
29625
29626
29627
29628
29629
29630
29631
29632
29633
29634
29635
29636
29637
29638
29639
29640
29641
29642
29643
29644
29645
29646
29647
29648
29649
29650
29651
29652
29653
29654
29655
29656
29657
29658
29659
29660
29661
29662
29663
29664
29665
29666
29667
29668
29669
29670
29671
29672
29673
29674
29675
29676
29677
29678
29679
29680
29681
29682
29683
29684
29685
29686
29687
29688
29689
29690
29691
29692
29693
29694
29695
29696
29697
29698
29699
29700
29701
29702
29703
29704
29705
29706
29707
29708
29709
29710
29711
29712
29713
29714
29715
29716
29717
29718
29719
29720
29721
29722
29723
29724
29725
29726
29727
29728
29729
29730
29731
29732
29733
29734
29735
*) Note AWG equivalet values – see page T 15. PVC cables will be changed to lead free PVC successively. Further dimensions and versions on request. For further single cores see the following pages: – for PVC, see pages D 1 – D 10. – for PUR, see page G 34. – for rubber, see pages G 33, O 15. – halogen-free, see pages G 23 – G 24, E 5, E 15 – E 16, E 24 – E 26. – heat-resistant, see pages E 5 – E 6, E 10 – E 11, E 13 – E 16, E 21, E 23 – E 25. – vehicle cables, see pages K 1 – K 4.
Works photo: HELUKABELâ
â
F 15
F
FROR CEI 20-22 II
Technical data
Cable structure
Application
– Special PVC-sheathed flexible cord – As per Italian standard CEI 20 – 22 II – Temperature range flexing – 58 C to +708 C fixed installation –358 C to +708 C – Nominal voltage U0/U 300/500 V = 1 mm2 U0/U 450/750 V 1,5 mm2 and above – Test voltage 2000 V – Insulation resistance min. 20 MOhm x km – Radiation resistance up to 80 x 106 cJ/kg (80 Mrad) – Minimum bending radius approx. 10 x cable 1 – PVC self-extinguishing and flame retardant, test methods analog to IEC 60332-3
– Bare copper conductor, fine wire stranded to CEI 20 – 29 cl. 5 – Special PVC compound Mi R 2 – Colour coded up and to 4 cores to HELUKABEL-JB colour code see page T 48 – As of 5 cores black with continuous white number printing – Green-yellow earth core – Cores stranded in layers with optimal lay-length – Special PVC outer sheath – Sheath colour grey, similar to RAL 7035, with printing CEI 20 – 22 II – Oil- and petrol resistant as per CEI 20 – 22 II
Well known companies (FIAT, COMAU, etc.) use this cable for measurement and control purposes on machine tools and conveyors, as well as on production lines in equipment production and for special mechanical engineering. These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. Due to special conductor insulation- and sheath compound, this cable is flame resistant in case of fire and self-extinguishing. The good oil- and petrol resistance allows the usage of this cable also in “problem“ areas.
– The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers = The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Part No.
No. cores x cross-sec. mm2
Outer 1 ca. mm
Cop. weight kg / km
Weight ca. kg / km
AWGno.*)
60250 60251 60252 60253 60254 60255 60256 60284 60285 60257 60258 60259
3G 1 4G 1 5G 1 7G 1 12G 1 18G 1 25G 1 27G 1 33G 1 34G 1 42G 1 50G 1
8,5 9,5 10,5 10,8 13,8 16,5 19,5 20,0 20,8 21,0 23,3 25,0
29 39 48 67 115 173 240 259 317 326 405 480
85 100 123 160 270 380 500 560 700 720 800 1050
17 17 17 17 17 17 17 17 17 17 17 17
60260 60261 60262 60263 60264 60265 60266 60267 60286 60268 60269
3G 1,5 4G 1,5 5G 1,5 7G 1,5 12G 1,5 18G 1,5 25G 1,5 34G 1,5 37G 1,5 42G 1,5 50G 1,5
9,6 11,0 12,0 12,5 16,0 18,8 23,0 26,0 26,5 29,5 30,5
43 58 72 101 173 259 360 490 533 605 720
105 150 190 220 350 515 705 990 1005 1080 1330
16 16 16 16 16 16 16 16 16 16 16
No. cores x cross-sec. mm2
Outer 1 ca. mm
Cop. weight kg / km
Weight ca. kg / km
AWGno.*)
60287 60270 60271 60272 60273
3G 2,5 4G 2,5 5G 2,5 7G 2,5 12G 2,5
11,3 12,3 12,6 14,5 18,0
72 96 120 168 288
190 215 270 350 550
14 14 14 14 14
60274 60275
4G 4 7G 4
14,0 16,0
154 269
300 500
12 12
60276 60277 60278 60279 60280 60281 60282 60283
4G 6 4G 10 4G 16 4G 25 4G 35 4G 50 4G 70 4G 95
16,0 19,0 23,0 28,0 31,0 37,0 43,0 50,0
230 384 614 960 1344 1920 2688 3648
430 700 1000 1550 2070 2850 4000 5400
10 8 6 4 2 1 2/0 3/0
Part No.
G = with green-yellow earth core X = without green-yellow earth core (OZ) *) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15. Further sizes available on request. Also available in screened version. PVC cables will be changed to lead free PVC successively.
F 16
â
C.N.O.M.O
type N05V V5-F according to NFC 32-206
Technical data
Cable structure
Application
– Special PVC based core insulation – As per to the french motor industry standard for tool machines 04-24-22 – Temperature range flexing – 58 C to +808 C fixed installation –308 C to +808 C – Nominal voltage 500 V – Test voltage 2000 V – Insulation resistance min. 20 MOhm x km – Radiation resistance up to 80 x 106 cJ/kg (80 Mrad) – Minimum bending radius 15 x cable 1
– – – –
Plain copper conductors Special core insulation Cores laid up Cores available in either red or black with white figure imprint – Green-yellow earth core – PVC outer jacket in blue or grey – PVC self-extinguishing and flame retardant, text method B and IEC 60332-1
These cables are constructed specially for the french automobile industries and used for the installation in tool making machines, production lines, industrial plants, air conditioning as well as for use in steel production. These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. Resistant to – Oil – Petrol – Cutting oil according to C.N.O.M.O recommendation E 03.40.150N
– The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
F
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Part No.
No. cores x cross-sec. mm2
Outer 1 ca. mm
Cop. weight kg / km
Weight ca. kg / km
AWGno.*)
60000 OZ 60001 60002 60003 60004 60005 60006 60007 60008 60009 60010
2 x 0,75 3G 0,75 4G 0,75 5G 0,75 6G 0,75 12G 0,75 18G 0,75 27G 0,75 36G 0,75 48G 0,75 60G 0,75
6,2 6,6 7,2 8,0 8,9 11,6 13,9 17,2 19,7 22,8 24,9
14,4 21,6 29,0 36,0 50,0 86,0 144,0 230,0 288,0 360,0 439,0
50 59 72 87 105 175 267 404 503 670 805
18 18 18 18 18 18 18 18 18 18 18
60011 OZ 60012 60013 60014 60015 60016 60017 60018 60019 60020 60021
2x1 3G 1 4G 1 5G 1 6G 1 12G 1 18G 1 27G 1 36G 1 48G 1 60G 1
6,5 6,9 7,7 8,5 9,2 12,4 15,2 18,7 21,1 24,3 26,4
19,0 29,0 38,0 48,0 67,0 115,0 192,0 308,0 384,0 480,0 586,0
56 72 84 104 124 219 314 485 620 809 1000
17 17 17 17 17 17 17 17 17 17 17
No. cores x cross-sec. mm2
Outer 1 ca. mm
Cop. weight kg / km
60022 OZ 60023 60024 60025 60026 60027 60028 60029 60030 60031 60032 60033
2 x 1,5 3G 1,5 4G 1,5 5G 1,5 6G 1,5 12G 1,5 18G 1,5 24G 1,5 27G 1,5 36G 1,5 48G 1,5 60G 1,5
7,5 8,1 9,1 10,1 11,0 15,1 17,9 21,0 21,8 24,5 28,4 31,3
29,0 43,0 58,0 72,0 101,0 173,0 263,0 341,0 372,0 498,0 641,0 878,0
76 94 116 143 173 307 464 629 708 985 1175 1415
16 16 16 16 16 16 16 16 16 16 16 16
60034 OZ 60035 60036 60037 60038 60039
2 x 2,5 3G 2,5 4G 2,5 5G 2,5 6G 2,5 12G 2,5
10,5 11,0 12,0 13,1 15,0 18,0
48,0 72,0 96,0 120,0 168,0 288,0
122 151 191 244 292 524
14 14 14 14 14 14
60040 OZ 60041 60042 60043
2x4 3G 4 4G 4 5G 4
10,4 11,3 12,8 14,2
77,0 115,0 154,0 192,0
178 230 300 362
12 12 12 12
60044 OZ 60045 60046 60047
2x6 3G 6 4G 6 5G 6
11,6 12,7 14,2 15,7
115,0 173,0 230,0 288,0
218 325 481 584
10 10 10 10
60048 OZ 60049 60050 60051
2 x 10 3G 10 4G 10 5G 10
15,0 16,6 18,4 20,9
194,0 288,0 384,0 480,0
505 610 736 913
8 8 8 8
Part No.
Weight ca. kg / km
AWGno.*)
G = with green-yellow earth core X = without green-yellow earth core (OZ) *) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15. Further types and sizes available on request. OZ = Version without earth core. PVC cables will be changed to lead free PVC successively.
â
F 17
â
HELUKABEL JZ-604 TC TRAY CABLE PVC-Power Cable, UL/cUL-approved 908 C 600 V
Technical data
Cable structure
Application
– PVC power cable to UL-standard 1277 TRAY CABLE – Multinorm The TRAY CABLE also conforms to the following standards: (UL) MTW to UL-Std. 1063 AWM-Style 2587 to UL-Std. 758 (cUL) and CSA type TC FT4 to C22.2 no 230 CSA C22.2 No 210.2 I/II A/B 908C 600 V FT4 – Temperature range dry environment flexing – 58 C to +908 C fixed installation –258 C to +908 C wet environment flexing – 58 C to +758 C fixed installation –258 C to +758 C – Nominal voltage to UL 600 V – Test voltage 3000 V – Breakdown voltage min. 6000 V – Insulation resistance min. 20 MOhm x km – Minimum bending radius 7,5 x cable 1 – Radiation resistance up to 80 x 106 cJ/kg (up to 80 Mrad)
– Bare copper, fine wire conductors, according to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC 60228 cl. 5 – Special PVC core insulation class 12 B to table 50.155 UL-standard 1581, type TFF to UL-Std. 62 table 6.2 (AWG 20–AWG 16), type THHW to UL-Std. 83 table 5.2 ($ AWG 14) – Black cores with continuous white numbering according to DIN VDE 0293 – Green-yellow earth core in the outer layer (3 cores and above) – Cores stranded in layers with optimal lay-lengt – Special PVC outer sheath, Y 2400 to UL-Std.1277 table 11.18 Sheath colour black (RAL 9005) – Material self-extinguishing and flame retardant to UL-Standard 1277
UL-approved, flexible high current cables for use up to 600 V, for all machines, tools and installation work. Suitable for use in dry, damp and wet areas, outside, in cable ducts, open cable trays. Also inpipes, in the ground and for open installation in machinery and industrial areas.
– The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Part No.
No. cores x cross-sec. mm2
AWGno.*)
Outer 1 ca. mm
Cop. weight kg / km
Weight ca. kg / km
69661 69662 69663 69664 69665 69666 69667 69668 69669 69670 69671 69672
2x1 3G 1 4G 1 5G 1 7G 1 9G 1 10G 1 12G 1 18G 1 25G 1 34G 1 50G 1
18 18 18 18 18 18 18 18 18 18 18 18
8,0 8,4 9,1 10,0 11,7 12,6 14,3 14,7 17,1 20,3 23,7 26,1
19,2 29 39 48 67 84 96 115 173 240 326 480
74 87 99 117 151 172 206 260 371 481 551 959
69673 69674 69675 69676 69677 69678 69679 69680 69681 69682 69683 69684 69685 69686 69687 69688
2 x 1,5 3G 1,5 4G 1,5 5G 1,5 7G 1,5 8G 1,5 9G 1,5 10G 1,5 12G 1,5 16G 1,5 18G 1,5 25G 1,5 34G 1,5 41G 1,5 50G 1,5 61G 1,5
16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16
8,4 8,8 9,6 10,5 12,3 13,3 13,3 15,1 15,6 17,1 18,2 22,7 25,3 26,7 27,3 29,4
28,8 43 58 72 101 115 130 144 173 230 259 360 489 590 720 878
91 105 122 147 192 213 261 294 331 402 430 597 714 803 1021 1238
AWGno.*)
Part No.
No. cores x cross-sec. mm2
AWGno.*)
Outer 1 ca. mm
Cop. weight kg / km
Weight ca. kg / km
69689 69690 69691 69692 69693 69694 69695 69696 69697 69698 69699
2 x 2,5 3G 2,5 4G 2,5 5G 2,5 7G 2,5 8G 2,5 9G 2,5 10G 2,5 12G 2,5 18G 2,5 25G 2,5
14 14 14 14 14 14 14 14 14 14 14
9,4 9,9 10,8 11,8 14,7 16,0 16,0 17,1 17,7 20,8 25,8
48 72 96 120 168 192 216 240 288 432 600
111 140 161 194 257 339 341 392 470 682 891
69700 69701 69702 69703 69704 69705 69706
3G 4 4G 4 5G 4 7G 4 9G 4 12G 4 18G 4
12 12 12 12 12 12 12
11,0 12,0 13,2 16,5 17,8 19,9 24,2
115 154 192 269 346 461 691
190 229 284 394 480 841 981
69707 69708 69709 69710
3G 6 4G 6 5G 6 7G 6
10 10 10 10
12,5 14,5 15,8 17,3
173 230 288 403
290 384 468 654
69711 69712 69713 69714
3G 10 4G 10 5G 10 7G 10
8 8 8 8
16,9 18,6 20,4 23,5
288 384 480 672
511 587 784 970
AWGno.*)
Continuation "
*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15.
F 18
G = with green-yellow earth core X = without green-yellow earth core (OZ) PVC cables will be changed to lead free PVC successively.
â
â
HELUKABEL JZ-604 TC TRAY CABLE PVC-Power Cable, UL/cUL-approbiert 908 C 600 V = The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Part No.
No. cores x cross-sec. mm2
AWGno.*)
Outer 1 ca. mm
Cop. weight kg / km
Weight ca. kg / km
69715 69716 69717 69718
3G 16 4G 16 5G 16 7G 16
6 6 6 6
21,0 23,9 26,3 28,8
461 614 768 1075
651 869 1117 1364
69719 69720 69721 69722
3G 25 4G 25 5G 25 7G 25
4 4 4 4
24,9 27,2 30,3 33,1
720 960 1200 1680
1090 1421 1611 1943
69723 69724 69725
3G 35 4G 35 5G 35
2 2 2
27,1 29,8 33,0
1008 1344 1680
1734 2011 2347
AWGno.*)
Part No.
No. cores x cross-sec. mm2
AWGno.*)
Outer 1 ca. mm
Cop. weight kg / km
Weight ca. kg / km
69726 69727 69728
3G 50 4G 50 5G 50
1 1 1
33,2 36,7 41,5
1440 1920 2400
2041 2539 2894
69729 69730 69731
3G 70 4G 70 5G 70
2/0 2/0 2/0
37,6 42,0 47,6
2016 2688 3360
2831 3494 4260
69732 69733 69734
3G 95 4G 95 5G 95
3/0 3/0 3/0
41,8 47,0 52,5
2736 3648 4560
5010 6104 7891
69735 69736 69737
3G 120 4G 120 5G 120
4/0 4/0 4/0
46,0 51,5 56,5
3456 4608 5760
5940 7604 8751
AWGno.*)
F
*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15.
G = with green-yellow earth core X = without green-yellow earth core (OZ) PVC cables will be changed to lead free PVC successively.
â
F 19
â
HELUKABEL JZ-604-FCY TC TRAY CABLE PVC Power Cable screened, UL/cUL approved, 908C 600 V, EMC* preferred type
Technical data
Cable structure
Application
– PVC power cable, screened to UL-standard 1277 TRAY CABLE – Multinorm The TRAY-CABLE also conforms to the following standards: (UL) MTW to UL-Std. 1063 AWM-Style 2587 to UL-Std. 758 (cUL) and CSA type TC FT4 to C22.2 no 230, CSA C22.2 No 210.2 I/II A/B 908 C 600 V FT4 – Temperature range dry environment flexing – 58 C to +908 C fixed installation –258 C to +908 C wet environment flexing – 58 C to +758 C fixed installation –258 C to +758 C – Nominal voltage to UL 600 V – Test voltage 3000 V – Breakdown voltage min. 6000 V – Insulation resistance min. 20 MOhm x km – Minimum bending radius 10 x cable 1 – Radiation resistance up to 80 x 106 cJ/kg (up to 80 Mrad) – Coupling resistance max. 250 Ohm/km
– Bare copper, fine wire conductors,according to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC 60228 cl. 5 – Spezial PVC core insulation class 12 B to table 50.155 UL-standard 1581, type TFF to UL-Std. 62 table 6.2 (AWG 20–AWG 16), type THHW to UL-Std. 83 table 5.2 ($ AWG 14) – Black cores with continuous white numbering according to DIN VDE 0293 – Grenn-yellow earth core in the outer layer (3 cores and above) – Cores stranded in layers with optimal lay-lenght – Special separation foil – Tinned copper braided screening, approx. 85% coverage – Special PVC outer sheath, Y 2400 to UL-Std. 1277 table 11.18, – Sheath colour black (RAL 9005) – Material self-extinguishing and flame retardant to UL-Standard 1277
UL-approved, flexible high current cables for use up to 600 V, for all machines, tools and installation work. Suitable for use in dry, damp and wet areas, outside, in cable ducts, open cable trays. Also in pipes, in the ground and for open installation in machinery and industrial areas. *EMC = Electromagnetic compatibillity Note To optimise the EMC features we recommend a large round contact of the cooper braiding on both ends.
– The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Part No.
No. cores x cross-sec. mm2
AWGno.*)
Outer 1 ca. mm
Cop. weight kg / km
Weight ca. kg / km
69750 69751 69752 69753 69754 69755 69756 69757 69758 69759 69760 69761
2x1 3G 1 4G 1 5G 1 7G 1 9G 1 10G 1 12G 1 18G 1 25G 1 34G 1 50G 1
18 18 18 18 18 18 18 18 18 18 18 18
8,6 9,0 9,7 10,5 12,2 13,2 15,0 15,4 17,8 21,1 24,5 26,2
51,2 76,4 102,9 126,4 204,8 269,8 304,7 331,1 494,7 642,1 807,6 892,1
151 164 200 229 306 371 411 460 624 845 984 1096
69762 69763 69764 69765 69766 69767 69768 69769 69770 69771 69772 69773 69774 69775 69776 69777
2 x 1,5 3G 1,5 4G 1,5 5G 1,5 7G 1,5 8G 1,5 9G 1,5 10G 1,5 12G 1,5 16G 1,5 18G 1,5 25G 1,5 34G 1,5 41G 1,5 50G 1,5 61G 1,5
16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16
9,0 9,4 10,2 11,1 12,9 14,5 14,5 15,8 16,2 17,9 18,9 22,3 24,9 26,7 33,7 36,0
78,3 114,2 152,1 189,2 279,4 308,6 326,8 401,6 491,7 526,1 749,1 1011,4 1214,7 2060,6 3040,8 3416,1
161 181 240 274 367 431 437 511 598 630 787 1240 1401 2671 3614 4089
AWGno.*)
Part No.
No. cores x cross-sec. mm2
AWGno.*)
Outer 1 ca. mm
Cop. weight kg / km
Weight ca. kg / km
69778 69779 69780 69781 69782 69783 69784 69785 69786 69787 69788
2 x 2,5 3G 2,5 4G 2,5 5G 2,5 7G 2,5 8G 2,5 9G 2,5 10G 2,5 12G 2,5 18G 2,5 25G 2,5
14 14 14 14 14 14 14 14 14 14 14
10,0 10,5 11,4 12,4 15,3 16,5 16,5 17,9 18,4 22,4 26,5
128,4 189,5 250,1 314,2 464,3 490,9 498,6 511,6 764,1 1120,4 1714,0
269 294 341 420 551 583 593 631 847 1336 1921
69789 69790 69791 69792 69793 69794 69795
3G 4 4G 4 5G 4 7G 4 9G 4 12G 4 18G 4
12 12 12 12 12 12 12
11,6 12,6 14,5 17,1 18,4 20,5 25,0
304,2 402,7 514,2 721,2 849,3 1211,8 1714,9
381 504 692 908 1104 1497 2104
69796 69797 69798 69799
3G 6 4G 6 5G 6 7G 6
10 10 10 10
13,8 15,1 16,4 18,0
457,2 608,6 763,9 1002,8
623 729 1082 1414
69800 69801 69802 69803
3G 10 4G 10 5G 10 7G 10
8 8 8 8
17,6 19,3 22,1 24,2
796,7 1029,6 1273,8 1696,2
1108 1324 1596 2186
AWGno.*)
Continuation " *) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15.
F 20
G = with green-yellow earth core X = without green-yellow earth core (OZ) PVC cables will be changed to lead free PVC successively.
â
â
HELUKABEL JZ-604-YCY TC TRAY CABLE PVC Power Cable screened, UL/cUL approved, 908C 600 V, EMC* preferred type
Technical data
Cable structure
Application
– PVC power cable, screened to UL-standard 1277 TRAY CABLE – Multinorm The TRAY-CABLE also conforms to the following standards: (UL) MTW to UL-Std. 1063 AWM-Style 2587 to UL-Std. 758 (cUL) and CSA type TC FT4 to C22.2 no 230, CSA C22.2 No 210.2 I/II A/B 908 C 600 V FT4 – Temperature range dry environment flexing – 58 C to +908 C fixed installation –258 C to +908 C wet environment flexing – 58 C to +758 C fixed installation –258 C to +758 C – Nominal voltage to UL 600 V – Test voltage 3000 V – Breakdown voltage min. 6000 V – Insulation resistance min. 20 MOhm x km – Minimum bending radius 10 x cable 1 – Radiation resistance up to 80 x 106 cJ/kg (up to 80 Mrad) – Coupling resistance max. 250 Ohm/km
– Bare copper, fine wire conductors,according to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC 60228 cl. 5 – Spezial PVC core insulation class 12 B to table 50.155 UL-standard 1581, type TFF to UL-Std. 62 table 6.2 (AWG 20–AWG 16), type THHW to UL-Std. 83 table 5.2 ($ AWG 14) – Black cores with continuous white numbering according to DIN VDE 0293 – Grenn-yellow earth core in the outer layer (3 cores and above) – Cores stranded in layers with optimal lay-lenght – PVC-inner sheath, Y 2400 to UL-Std. 1277 table 11.18l – Tinned copper braided screening, approx. 85% coverage – Special PVC outer sheath, Y 2400 to UL-Std. 1277 table 11.18, – Sheath colour black (RAL 9005) – Material self-extinguishing and flame retardant to UL-Standard 1277
UL-approved, flexible high current cables for use up to 600 V, for all machines, tools and installation work. Suitable for use in dry, damp and wet areas, outside, in cable ducts, open cable trays. Also in pipes, in the ground and for open installation in machinery and industrial areas. *EMC = Electromagnetic compatibillity Note To optimise the EMC features we recommend a large round contact of the cooper braiding on both ends.
F
– The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. Part No.
No. cores x cross-sec. mm2
AWGno.*)
Outer 1 ca. mm
Cop. weight kg / km
Weight ca. kg / km
69804 69805 69806 69807
3G 16 4G 16 5G 16 7G 16
6 6 6 6
25,2 27,8 31,2 34,5
1245,1 1655,2 2063,6 2886,5
1385 1861 2614 3211
69808 69809 69810 69811
3G 25 4G 25 5G 25 7G 25
4 4 4 4
29,0 32,4 34,2 40,3
1932,0 2561,1 3140,2 4481,7
2455 2721 3490 4960
69812 69813 69814
3G 35 4G 35 5G 35
2 2 2
32,4 36,2 40,5
2504,7 3320,8 4180,8
3130 4100 4921
*) Note AWG sizes are approximate equivalent values. The actual cross-section is in mm2 – see page T 15.
AWGno.*)
Part No.
No. cores x cross-sec. mm2
AWGno.*)
Outer 1 ca. mm
Cop. weight kg / km
Weight ca. kg / km
69815 69816 69817
3G 50 4G 50 5G 50
1 1 1
40,4 45,5 50,0
3520,1 4821,7 5820,8
4560 5761 7186
69818 69819 69820
3G 70 4G 70 5G 70
2/0 2/0 2/0
47,1 51,1 56,0
5020,1 6620,3 8420,4
5580 7387 9290
69821 69822 69823
3G 95 4G 95 5G 95
3/0 3/0 3/0
50,1 55,0 60,5
6724,3 9100,0 10940,1
8520 10200 13800
69824 69825 69826
3G 120 4G 120 5G 120
4/0 4/0 4/0
54,0 59,5 64,5
8620,7 11420,0 12940,4
11090 13620 15420
AWGno.*)
G = with green-yellow earth core X = without green-yellow earth core (OZ) PVC cables will be changed to lead free PVC successively.
â
F 21