Calculation of glomerular filtration rate expressed in mL ... - CiteSeerX

22 downloads 0 Views 54KB Size Report
Calculation of glomerular filtration rate expressed in mL/min from plasma cystatin C values in mg/L. A. LARSSON,* J. MALM,{ A. GRUBB{ & L.-O. HANSSON*.
Scand J Clin Lab Invest 2004; 64: 25 – 30

Calculation of glomerular filtration rate expressed in mL/min from plasma cystatin C values in mg/L A. LA R SSO N,* J . M AL M,{ A. GRUBB { & L . - O . H A N S S O N * *Department of Medical Sciences University Hospital, Uppsala, Sweden; {Department of Clinical Chemistry, University Hospital MAS, Malmo¨, Sweden; {Department of Clinical Chemistry, University Hospital, Lund, Sweden

Larsson A, Malm J, Grubb A, Hansson L-O. Calculation of glomerular filtration rate expressed in mL/min from plasma cystatin C values in mg/L. Scand J Clin Lab Invest 2004; 64: 25–30. The Cockcroft – Gault formula is often used to calculate the glomerular filtration rate (GFR) from plasma creatinine results. In Sweden this calculation is not usually done in the laboratory, but locally in the wards. These manual calculations could cause erroneous results. In several studies plasma cystatin C has been shown to be superior to plasma creatinine for estimation of GFR. One limitation of using cystatin C as a GFR marker is that there is no conversion formula transforming cystatin C expressed as mg/L to GFR expressed as mL/ min. In this study plasma creatinine and cystatin C were compared with iohexol clearance. A stronger correlation (pv0.0001) was found between cystatin C and iohexol clearance (r2~0.91) than between creatinine and iohexol clearance (r2~0.84). From the correlation data a formula was calculated to convert cystatin C expressed as mg/L to GFR (mL/min). The formulas y~77.24x21.2623 (Dade Behring cystatin C calibration) or y~99.43x21.5837 (DakoCytomation cystatin C calibration) are used to calculate GFR expressed in mL/min from the cystatin C value in mg/L and both results are reported to the referral doctor. These formulas can provide the clinicians with reliable and readily available GFR data based on single measurements of cystatin C concentrations. Key words: Creatinine; cystatin C; glomerular filtration ratio; iohexol; kidney Anders Larsson, Department of Medical Sciences, University Hospital, SE-751 85 Uppsala, Sweden. Tel. z46 18 6110 000, fax. z46 18 552 562, e-mail. [email protected]

IN T R O D U C T I O N In the past few decades, serum or plasma creatinine has become the most commonly used marker of glomerular filtration rate (GFR) [1, 2]. Despite its common use, creatinine has DOI 10.1080/00365510410003723

limitations as a marker for renal function. GFR is often calculated from plasma creatinine using the Cockcroft – Gault formula [3]. Cockcroft – Gault (CCr)~(140 – age)/(serum creatinine) * (weight/72) * (0.85 for women) * BSA/1.73 m2, where BSA is body surface area, estimated 25

26

A. Larsson et al.

using the formula [4]: BSA (m2)~0.202476 height (m)0.7256weight (kg)0.425. This equation consists of several parts, which introduces several possibilities for erroneous results, especially if the calculation is performed manually. Creatinine is influenced by factors such as age, gender, muscle mass, physical activity and diet [5]. Owing to the non-linear relationship between plasma concentration and GFR [6], creatinine also lacks sensitivity in detecting small decreases in GFR, in the so-called creatinine-blind GFR area. Thus, better GFR markers are needed. Several markers such as btrace protein, cystatin C and b2-microglobulin have been suggested as alternatives to creatinine [7 – 9]. The normal plasma level of cystatin C is v1.20 mg/L for patients under 50 years of age and v1.55 mg/L for patients over 50 years of age, while increasing levels are detected in the plasma of patients with reduced GFR. In our laboratory we have been using plasma cystatin C as a marker for GFR. Cystatin C is a polypeptide with a molecular mass of 13 kDa and a probable ellipsoid shape with axes of about 30 ˚ [10]. The amino acid sequence of and 45 A human cystatin C was determined in 1981 [11]. Cystatin C functions as an inhibitor of cysteine proteases and can be found in all body fluids [12]. The cystatin C gene is of the housekeeping type, which indicates a stable production rate of cystatin C by most nucleated cell types [13]. The synthesis of cystatin C is not influenced by age, gender or inflammatory response. Plasma proteins with molecular masses below 15 – 20 kDa are generally almost freely filtered through the normal glomerular membrane. Studies of the handling of human cystatin C in the rat have shown that the plasma clearance of cystatin C is 94% of that of the generally used GFR marker 51 Cr-EDTA [14]. The results of a recent meta-analysis indicate that cystatin C is superior to plasma creatinine [15] as a marker of renal function. One persisting problem with using cystatin C as a GFR marker is that there is no procedure to transform cystatin C concentrations in mg/L to GFR values in mL/min. The latter is often used to calculate, for example, the correct amount of antibiotics or cytotoxic drugs for individual patients. In order to provide clinicians with reliable and readily available GFR data based on single measurements of cystatin C, we have compared the results obtained by iohexol

clearance measurements in mL/min and plasma cystatin C mass concentration values in mg/mL. The results were then used to calculate an equation converting cystatin C in mg/L to GFR in mL/min and compared with determinations of creatinine as a GFR marker.

M A T E R I A L S A N D ME T H O D S Patient samples and assays Patients referred to the Department of Clinical Chemistry, University Hospital MAS, Malmo¨ for routine iohexol clearance were included in the study (40 females and 60 males; age range 4 – 92 years). GFR was determined by measuring the plasma clearance of iohexol, a radiocontrast agent, which is a reliable marker for GFR [16, 17]. Each patient was given 5 mL iohexol solution (Omnipaque, Nycomed Amersham) intravenously in an antecubital vein. Clearance was calculated from the iohexol concentration 4 h after the injection [18]. Serum iohexol levels were determined by high-pressure liquid chromatography [17, 19]. The total analytical imprecision of the method was 3.9% using a control sample with an assigned value of 32 mg/L and 4.3% for a control sample with an assigned value of 137 mg/L. Plasma cystatin C measurements were done with a latex enhanced reagent (N Latex Cystatin C, Dade Behring, Deerfield, IL, USA) using a Behring BN ProSpec analyzer (Dade Behring). The total analytical imprecision of the method was 4.8% at 0.56 mg/L and 3.7% at 2.85 mg/L. The results were converted to DakoCytomation (Glostrup, Denmark) calibration with the formula: DakoCytomation result~0.85 * ProSpec resultz0.35. This conversion was made in order to obtain comparable results between different laboratories in Sweden. Plasma creatinine measurements were performed with the modified kinetic Jaffe reaction using an Advia 1650 analyzer (Bayer Corp., Tarrytown, NY, USA) and reported using SI units (mmol/L). The total analytical imprecision of the method was 2.6% at 170 mmol/L and 2.4% at 740 mmol/L. Both these assays were carried out at the Department of Clinical Chemistry, University Hospital, Uppsala. All assays were performed independently without

GFR in mL/min from cystatin C in mg/L prior knowledge of other test results. The study was approved by the local ethics board at Uppsala University (01-167).

27

cystatin C method (mg/L) to obtain the formula: y~77.24x21.2623 and DakoCytomation calibration of the cystatin C method (mg/L) to obtain the formula: y~99.43x21.5837

Statistical calculations Statistical analysis was performed with Excel 2000 (Microsoft Corporation, Seattle, WA, USA). Equations for the correlation curves were calculated by using ‘‘best fit’’ in Excel (Microsoft Corporation).

Correlation between creatinine and iohexol clearance There was a significantly stronger correlation (pv0.0001) between cystatin C (mg/L) and iohexol clearance (r2~0.91) than between creatinine (mmol/L) and iohexol clearance (r2~0.84) (Figs 1 – 3).

RES UL TS Correlation between cystatin C and iohexol clearance

D I S C US S I O N

Cystatin C values (mg/L) obtained with Dade Behring calibration (Fig. 1) and DakoCytomation calibration (Fig. 2) both showed a strong correlation with iohexol clearance (r2~0.91). Equations for the two correlation curves were calculated. We used Dade Behring calibration of the

Glomerular filtration rate is generally accepted as the best overall index of renal function. Reduced GFR is the most important complication of renal disease. Reduced GFR influences the metabolism and clearance of many pharmaceuticals used today. Thus, in many cases the recommended dose has to be adjusted

FIG. 1. Correlation between cystatin C (Dade Behring calibration) and iohexol clearance for individual patients.

28

A. Larsson et al.

FIG. 2.

Correlation between cystatin C (Dako calibration) and iohexol clearance for individual patients.

FIG. 3.

Correlation between creatinine and iohexol clearance for individual patients.

GFR in mL/min from cystatin C in mg/L

FIG. 4. Correlation between calculated glomerular filtration rate (GFR) from cystatin C (Dade calibration) analysis versus iohexol determination of GFR.

depending on the patient’s GFR. For instance, because antibiotics and cytotoxic drugs are usually prescribed according to GFR, there is a need for GFR markers. Inulin, iohexol and 51 Cr-EDTA clearances are considered the gold standards for GFR measurements. The disadvantage with these assays is that they are cumbersome, costly and slow, which could delay the start of treatment. Assays such as plasma creatinine and cystatin C can provide rapid test results. Creatinine in combination with the Cockcroft – Gault equation is often used to estimate GFR. Using actual body weight in the Cockcroft – Gault equation overestimates the GFR for obese patients. An alternative could be to use lean body mass, but this is not commonly available. Creatinine often overestimates GFR in patients with slightly reduced GFR. This may cause the doctor to treat the patient with unnecessarily high drug doses, which will increase the cost and possibly cause side effects. In Sweden, calculation of GFR using the Cockcroft – Gault equation is generally performed locally in the wards. The equation contains height and weight that may be difficult to measure correctly in all cases. To increase the quality of GFR measurements we are currently in the process of replacing plasma creatinine measurements with plasma cystatin C, which in our opinion and experience is a better marker for GFR than plasma creatinine. Cystatin C results are given in the unit mg/L and a constant problem is that the doctor has to convert a mass concentration value in mg/L to a GFR value in mL/min. With the ubiquitous use of computers in the clinical chemistry laboratory, no human intervention for such a

29

calculation should be required and the present study suggests two suitable formulas for transforming a cystatin C result in mg/mL to a GFR result in mL/min. In the present investigation, a cluster of iohexol results of around 10 – 20 mL/min can be observed, while the corresponding cystatin C results vary between 2.5 and 4.5 mg/L. This could indicate that cystatin C has a better discriminatory capability than iohexol clearance in patients with GFR in the 10 – 20 mL/min range. We have measured cystatin C levels in samples from patients whose GFRs were determined using the iohexol clearance method. The results have then been used to calculate an equation to convert cystatin C levels in mg/mL to GFR in mL/min. This has been greatly appreciated by our clinical colleagues and has contributed to the rapid increase in the use of cystatin C as a GFR marker. The assay is available as stat. sample at all hours in our laboratory.

A C K NO W L E D G E M E NT S We greatly appreciate the technical assistance of technicians Charina Bra¨nnstro¨m, May-Lill Svensson and Ann-Christin Ma˚rtensson.

R E F E RE N C E S 1 Schwartz GJ, Haycock GB, Edelmann Jr, CM, Spitzer A. A simple estimate of glomerular filtration rate in children derived from body length and plasma creatinine. Pediatrics 1976; 58: 259 – 63. 2 Kemperman FA, Krediet RT, Arisz L. Formuladerived prediction of the glomerular filtration rate from plasma creatinine concentration. Nephron 2002; 91: 547 – 58. 3 Cockcroft DW, Gault MH. Prediction of creatinine clearance from serum creatinine. Nephron 1976; 16: 31 – 41. 4 DuBois D, Dubois EF. A formula to estimate the approximate surface area if height and weight be known. Arch Intern Med 1916; 17: 863 – 71. 5 Hsu CY, Chertow GM, Curhan GC. Methodological issues in studying the epidemiology of mild to moderate chronic renal insufficiency. Kidney Int 2002; 61: 1567 – 76. 6 Sherman DS, Fish DN, Teitelbaum I. Assessing renal function in cirrhotic patients: problems and pitfalls. Am J Kidney Dis 2003; 41: 269 – 78.

30

A. Larsson et al.

7 Grubb A, Simonsen O, Sturfelt G, Truedsson L, Thysell H. Serum concentration of cystatin C, factor D and b2-microglobulin as a measure of glomerular filtration rate. Acta Med Scand 1985; 218: 499 – 503. 8 Filler G, Priem F, Lepage N, Sinha P, Vollmer I, Clark H, Keely E, Matzinger M, Akbari A, Althaus H, Jung K. Beta-trace protein, cystatin C, beta(2)-microglobulin, and creatinine compared for detecting impaired glomerular filtration rates in children. Clin Chem 2002; 48: 729 – 36. 9 Grubb AO. Cystatin C—properties and use as diagnostic marker. Adv Clin Chem 2000; 35: 63 – 99. 10 Bode W, Engh R, Musil D, Thiele U, Huber R, Karshikov A, Brzin J, Kos J, Turk V. The 2.0 A X-ray crystal structure of chicken egg white cystatin and its possible mode of interaction with cysteine proteinases. EMBO J 1988; 7: 2593 – 9. 11 Grubb A, Lo¨fberg H. Human c-trace, a basic microprotein: amino acid sequence and presence in the adenohypophysis. Proc Natl Acad Sci USA 1982; 79: 3024 – 7. 12 Abrahamson M, Barrett AJ, Salvesen G, Grubb A. Isolation of six cysteine proteinase inhibitors from human urine. Their physicochemical and enzyme kinetic properties and concentrations in biological fluids. J Biol Chem 1986; 261: 11282 – 9. 13 Abrahamson M, Olafsson I, Palsdottir A, ˚ , Jensson O, Grubb A. Ulvsba¨ck M, Lundwall A

14

15

16

17

18

19

Structure and expression of the human cystatin C gene. Biochem J 1990; 268: 287 – 94. Tenstad O, Roald AB, Grubb A, Aukland K. Renal handling of radiolabelled human cystatin C in the rat. Scand J Clin Lab Invest 1996; 56: 409 – 14. Dharnidharka VR, Kwon C, Stevens G. Serum cystatin C is superior to serum creatinine as a marker of kidney function: a meta-analysis. Am J Kidney Dis 2002; 40: 221 – 6. Ba¨ck SE, Krutzen E, Nilsson-Ehle P. Contrast media as markers for glomerular filtration: a pharmacokinetic comparison of four agents. Scand J Clin Lab Invest 1988; 48: 247 – 53. Krutzen E, Ba¨ck SE, Nilsson-Ehle I, Nilsson-Ehle P. Plasma clearance of a new contrast agent, iohexol: a method for the assessment of glomerular filtration rate. J Lab Clin Med 1984; 104: 955 – 61. Sterner G, Frennby B, Hultberg B, Almen T. Iohexol clearance for GFR-determination in renal failure—single or multiple plasma sampling? Nephrol Dial Transplant 1996; 11: 521 – 5. Nilsson-Ehle P. Iohexol clearance for the determination of glomerular filtration rate: 15 years’ experience in clinical practice eJIFCC vol. 13 no. 2: http://www.ifcc.org/ejifcc/vol13no2/ 130201005.htm

Received: 7 April 2003 Accepted: 12 November 2003

Suggest Documents