CE MARK TECHNICAL FILE of. WLAN a+b+g mini-PCI Module. Model. CM9.
Contains: 1. Declaration of Conformity. 2. ETSI EN300 328 or/& ETSI EN301 893
...
CE MARK TECHNICAL FILE
of
WLAN a+b+g mini-PCI Module
Model
CM9 Contains: 1. Declaration of Conformity 2. ETSI EN300 328 or/& ETSI EN301 893 test report 3. ETSI EN301 489-1 and ETSI EN301 489-17 4. EN61000-3-2/AS/NZS 61000.3.2 test report 5. EN61000-3-3/AS/NZS 61000.3.3 test report 6. Block Diagram and Schematics 7. User`s manual
Wistron Neweb Corporation No. 10-1, Li-hsin Road 1, Science-based Industrial Park,Hsinchu 300, Taiwan, R. O. C. Tel: 886-3-666-7799 Fax: 886-3-666-1654 Page 1 of 2
Declaration of Conformity Name of Manufacturer: Address of Manufacturer: Declares that product: Model:
Wistron NeWeb Corporation No. 10-1, Li-Hsin Road I, Science-based Industrial Park Hsinchu 300, Taiwan, R. O. C. WLAN a+b+g mini-PCI Module CM9
Assembled by: Address:
Same as above Same as above
Conformed to the EMC Directive 99/5/EC as attested by conformity with the following harmonized standards: ETSI EN300 328-2 V1.2.1: ERM; wideband transmission systems; data transmission equipment operating in the 2.4Ghz ISM band and using spread spectrum modulation techniques. ETSI EN301 893 V1.2.1: BRAN; 5Ghz high performance RLAN. ETSI EN301 489-1 V1.2.1 and ETSI EN301 489-17 V1.2.1: ERM; EMC standard for radio equipment and service; specific conditions for wideband data and HIPERLAN equipment. Standard
Description
Results
Criteria
EN61000-4-2: 1995/A1: 1998/A2: 2001 AS/NZS 61000.4.2: 2002
Electrostatic Discharge
Pass
B
EN61000-4-3: 1996/A1: 1998/A2: 2001 AS/NZS 61000.4.3: 1999
Radio-Frequency, Electromagnetic Field
Pass
A
EN61000-4-4: 1995/A1: 2001/A2: 2001 AS/NZS 61000.4.4: 1999
Electrical Fast Transient/Burst
Pass
B
EN61000-4-5: 1995/A1: 2001 AS/NZS 61000.4.5: 1999
Surge
Pass
B
EN61000-4-6: 1996/A1: 2001 AS/NZS 61000.4.6: 1999
Conductive Disturbance
Pass
A
EN61000-4-8: 1993/A1: 2001 AS/NZS 61000.4.8: 2002
Power Frequency Magnetic Field
N/A
A
EN61000-4-11: 1994/A1: 2001 AS/NZS 61000.4.11: 1999
Voltage Dips / Short Interruption and Voltage Variation 30% in 10ms
Pass
B
60% in 100ms
Pass
C
>95% in 5000ms
Pass
C
Wistron Neweb Corporation No. 10-1, Li-hsin Road 1, Science-based Industrial Park,Hsinchu 300, Taiwan, R. O. C. Tel: 886-3-666-7799 Fax: 886-3-666-1654
Page 2 of 2
Standard
Description
Results
EN61000-3-2: 2000 AS/NZS 61000.3.2: 2003
Limits for harmonics current emissions
Pass
EN61000-3-3: 1995 A1: 2001/ AS/NZS 61000.3.3: 1998
Limits for voltage fluctuations and flicker in low-voltage supply systems .
Pass
We, Wistron NeWeb Corporation, hereby declare that the equipment bearing the trade name and model number specified above was tested conforming to the applicable Rules under the most accurate measurement standards possible, and that all the necessary steps have been taken and are in force to assure that production units of the same equipment will continue to comply with the requirements.
---------------------------
Edward Yeh/ Engineer Wistron NeWeb Corporation Date: 2004/06/04
No. 65, Ku Dai Keng St., Hsichih, Taipei 221, R.O. C. Tel: 886-2-2646-2550 FAX: 886-2-26464641 No. 120, Lane 180, San Ho Tsuen, Hsin Ho Rd. Lung-Tan Hsiang, Tao Yuan County 325, Taiwan, R.O.C. Tel: 886-3-407-1718 FAX:886-3-407-1738
Product Name: Model Number(s):
WLAN a+b+g mini-PCI Module
Responsible Party Address:
Wistron Neweb Corporation No. 10-1, Li-hsin Road 1, Science-based Industrial Park,Hsinchu 300, Taiwan, R. O. C. Edward Yeh
Contact Person:
CM9
Issue Date: 2004/06/04 Test Report No.: 04LR018E489
We, International Standards Laboratory, hereby certify that: The device bearing the trade name and model specified above has been shown to comply with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in EMC Directive 99/5/EC. The device was passed the test performed according to : ETSI EN300 328-2 V1.2.1: ERM; wideband transmission systems; data transmission equipment operating in the 2.4Ghz ISM band and using spread spectrum modulation techniques. ETSI EN301 893 V1.2.1: BRAN; 5Ghz high performance RLAN. ETSI EN301 489-1 V1.2.1 and ETSI EN301 489-17 V1.2.1: ERM; EMC standard for radio equipment and service; specific conditions for wideband data and HIPERLAN equipment. EN61000-4-2: 1995/A1: 1998/A2: 2001 AS/NZS 61000.4.2: 2002
EN61000-4-6: 1996/A1: 2001 AS/NZS 61000.4.6: 1999
EN61000-4-3: 1996/A1: 1998/A2: 2001 AS/NZS 61000.4.3: 1999
EN61000-4-8: 1993/A1: 2001 AS/NZS 61000.4.8: 2002
EN61000-4-4: 1995/A1: 2001/A2: 2001 AS/NZS 61000.4.4: 1999
EN61000-4-11: 1994/A1: 2001 AS/NZS 61000.4.11: 1999
EN61000-4-5: 1995/A1: 2001 AS/NZS 61000.4.5: 1999
EN61000-3-2: 2000/AS/NZS 61000.3.2: 2003: Limits for harmonics current emissions. EN61000-3-3: 1995/A1: 2001/ AS/NZS 61000.3.3: 1998: Limits for voltage fluctuations and flicker in low-voltage supply systems. I attest to the accuracy of data and all measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them.
--------------------------------------Eddy Hsiung/Director International Standards Laboratory
EN55024 / AS/NZS CISPR 24 / IMMUNITY ETSI EN 301 489-1 & ETSI EN 301 489-17 EN61000-3-2 / HARMONICS EN61000-3-3 / VOLTAGE FLUCTUATIONS TEST REPORT of
WLAN a+b+g mini-PCI Module
Model
CM9 (Brand: Wistron NeWeb)
Applied by: Wistron NeWeb Corporation No. 10-1, Li-Hsin Road I, Science-based Industrial Park Hsinchu 300, Taiwan, R. O. C. Test Performed by: (NVLAP Lab. Code: 200234-0) International Standards Laboratory No. 120, Lane 180, San Ho Tsuen, Hsin Ho Rd. Lung-Tan Hsiang, Tao Yuan County 325 Taiwan, R.O.C. Tel:(03)407-1718 Fax:(03)407-1738
Report Number: ISL-04LR018E489
Test Date: 2004/06/04
HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997 T10-R1-10
-iContents of Report 1.
General.............................................................................................................................. 1 Certification of Accuracy of Test Data............................................................................. 1 2. Summary........................................................................................................................... 2 2.1 Applicant Information...................................................................................................... 2 2.2 Test Standards................................................................................................................ 2 2.3 Operation Environment ................................................................................................... 2 2.4 Description of Support Equipment................................................................................... 3 2.4.1 Software for Controlling Support Unit....................................................................... 5 2.4.2 I/O Cable Condition of EUT and Support Units........................................................ 6 2.5 Description of Equipment Under Test (EUT) ................................................................... 7 3. Electrostatic discharge (ESD) immunity............................................................................... 9 3.1 Electrostatic discharge (ESD) immunity test ..................................................................... 9 4. Radio-Frequency, Electromagnetic Field immunity............................................................ 11 4.1 Radio-Frequency, Electromagnetic Field immunity test................................................... 11 5. Electrical Fast transients/burst immunity............................................................................. 12 5.1 Electrical Fast transient/burst immunity test..................................................................... 12 6. Surge Immunity................................................................................................................ 14 6.1 Surge immunity test....................................................................................................... 14 7. Immunity to Conductive Disturbance................................................................................. 15 7.1 Immunity to Conductive Disturbance ............................................................................. 15 8. Power Frequency Magnetic Field immunity....................................................................... 16 8.1 Power Frequency Magnetic field immunity test............................................................... 16 9. Voltage Dips, Short Interruption and Voltage Variation immunity....................................... 17 9.1 Voltage Dips, Short Interruption and Voltage Variation immunity test ............................. 17 10. Harmonics ....................................................................................................................... 18 10.1 Harmonics test .......................................................................................................... 18 11. Voltage Fluctuations......................................................................................................... 21 11.1 Voltage Fluctuations test............................................................................................ 21 12. Test Equipment List.......................................................................................................... 23 12.1 Software for Controlling Spectrum/Receiver and Calculating Test Data....................... 24 13. Photographs..................................................................................................................... 25 13.1 Photos of ESD measurement ..................................................................................... 25 13.2 Photos of RF Field Strength Susceptibility Measurement ............................................ 25 13.3 Photos of Electrical Fast Transient/Burst measurement................................................ 26 13.4 Photos of Surge measurement.................................................................................... 26 13.5 Photo of Conductive Measurement ............................................................................ 27 13.6 Photo of Magnetic field measurement......................................................................... 27 13.7 Photos of Voltage Dips measurement......................................................................... 28 13.8 Photos of Harmonics and Voltage Fluctuations........................................................... 28 13.9 Appendix: Photographs of EUT................................................................................. 29 1.1
International Standards Laboratory
Report Number: ISL-04LR018E489
HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-11.
General
1.1 Certification of Accuracy of Test Data The immunity tests which this report describes were conducted by an independent electromagnetic compatibility consultant, International Standards Laboratory in accordance with the EN55024: 1998/A1:2001 / ETSI EN301 489-1 (2001-09), ETSI EN301 489-17 (2001-09) / AS/NZS CISPR 24:
1997 which include EN61000-4 series regulations, Harmonic Current Emissions EN61000-3-2: 2000 / AS/NZS 61000.3.2: 2003, and Voltage Fluctuations EN61000-3-3: 1995/A1: 2001 / AS/NZS 61000.3.3: 1998. Equipment Tested: WLAN a+b+g mini-PCI Module Model: CM9 Applied by Wistron NeWeb Corporation Date of test:
2004/06/03
Test Site:
LT Test Site
Test Engineer:
Jerry Chiou
Approve & Signature
---------------------------------------------
Eddy Hsiung/Director Test results given in this report apply only to the specific sample(s) tested under stated test conditions. This report shall not be reproduced other than in full without the explicit written consent of ISL. This report totally contains 31 pages, including 1 cover page , 1 contents page, and 29 pages for the test description. This report must not be use to claim product endorsement by NVLA, NIST, any agency of the federal government. This test report accurately contains the test results of the above standards at the time of the test. The results in this report apply only to the sample(s) tested. This test report shall not be reproduced except in full, without the written approval of International Standards Laboratory.
International Standards Laboratory
Report Number: ISL-04LR018E489
HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-22.
Summary
2.1 Applicant Information Applicant:
Wistron NeWeb Corporation No. 10-1, Li-Hsin Road I, Science-based Industrial Park Hsinchu 300, Taiwan, R. O. C.
2.2 Test Standards
ETSI EN301 489-1 V1.2.1 and ETSI EN301 489-17 V1.2.1: ERM; EMC standard for radio equipment and service; specific conditions for wideband data and HIPERLAN equipment. Standard
Description
Results
Criteria
EN61000-4-2: 1995/A1: 1998/A2: 2001 AS/NZS 61000.4.2: 2002
Electrostatic Discharge
Pass
B
EN61000-4-3: 1996/A1: 1998/A2: 2001 AS/NZS 61000.4.3: 1999
Radio-Frequency, Electromagnetic Field
Pass
A
EN61000-4-4: 1995/A1: 2001/A2: 2001 AS/NZS 61000.4.4: 1999
Electrical Fast Transient/Burst
Pass
B
EN61000-4-5: 1995/A1: 2001 AS/NZS 61000.4.5: 1999
Surge
Pass
B
EN61000-4-6: 1996/A1: 2001 AS/NZS 61000.4.6: 1999
Conductive Disturbance
Pass
A
EN61000-4-8: 1993/A1: 2001 AS/NZS 61000.4.8: 2002
Power Frequency Magnetic Field
N/A
A
EN61000-4-11: 1994/A1: 2001 AS/NZS 61000.4.11: 1999
Voltage Dips / Short Interruption and Voltage Variation 30% in 10ms
Pass
B
60% in 100ms
Pass
C
>95% in 5000ms
Pass
C
Standard
Description
Results
EN61000-3-2: 2000 AS/NZS 61000.3.2: 2003
Limits for harmonics current emissions
Pass
EN61000-3-3: 1995 A1: 2001/ AS/NZS 61000.3.3: 1998
Limits for voltage fluctuations and flicker in low-voltage supply systems .
Pass
2.3 Operation Environment Power supply : AC 230 V / 50 Hz
International Standards Laboratory
Report Number: ISL-04LR018E489
HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-32.4 Description of Support Equipment
Support Unit 1. Description: Model Number: Serial Number: Power Supply Type: Power Cord: FCC ID:
Acer USB Keyboard 6511-UV N/A N/A N/A N/A (comply with FCC DOC)
Support Unit 2. Description: Model Number: Serial Number: Power Supply Type: Power Cord: FCC ID:
DELL USB Mouse M-UR69 LNA24412741 N/A N/A N/A (Comply with FCC DOC)
Support Unit 3. Description: Model: Serial Number: Power Cord: FCC ID:
Acer Monitor G781 999007101214400445T7AA31T Non-shielded, Detachable (Comply with FCC Standards)
Support Unit 4. Description: Model Number: Serial Number: Power Supply Type: Power Cord: Data Cable: FCC ID:
International Standards Laboratory
HP Printer (for parallel interface port) C2642A TH84T1N3J3 AC Adaptor (HP Model: C2175A) Non-shielded, Detachable Shielded, Detachable, With Metal Hood B94C2642X
Report Number: ISL-04LR018E489
HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-4-
Support Unit 5. Description: Model No.: Brand: AC Power Adapter Manufacturer: HDD: Modem Card: FDD: SDRAM: 1394 C0nnector: USB Connector: RJ11 Connector: RJ45 Connector: VGA Connector: PCMCIA Slot Line out Port: Line-in Port: Parallel Port DC IN Port: Battery: LCD: CPU
International Standards Laboratory
Notebook Personal Computer Aspire1510,ZP2,ZP2A acer LSE(Model:ADP-90FB REV:F) HGST (Model: IC25N030ATMR04-0) Ambit (Model: T60M283.10) Panasonic (Model:UJ-266A343FC) Infineon (Model:HYS64D32020GDL-6-B) one 4 Pins four 4 Pins one 2 Pins one 8 Pins one 15 Pins one one one one 25pins one Li-ION DC14.8V 4400mAh QSI (Model:QD150XL06-01) AMD Athlon 64 2800+
Report Number: ISL-04LR018E489
HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-5-
2.4.1 Software for Controlling Support Unit Test programs exercising various part of EUT were used. The programs were executed as follows: A. Read and write to the disk drives. B. Send H pattern to the video port device (Monitor). C. Send H pattern to the parallel port device (Printer). D. Repeat the above steps.
Filename
Issued Date
Printer1
Wordpad.exe
11/11/1999
Monitor
HH.bat
8/20/1991
International Standards Laboratory
Report Number: ISL-04LR018E489
HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-62.4.2 I/O Cable Condition of EUT and Support Units
Description
Path
Cable Length
Cable Type
Connector Type
AC Power Cord
110V (~240V) to AC Power Cord Inlet (3-pin)
1.8M
Nonshielded, Detachable
Plastic Head
Printer Data Cable
Printer to PC Parallel port
1.5M
Shielded, Detachable
Metal Head
Monitor Data Cable
Monitor to PC VGA port
1.6M
Shielded, Un-detachable
Metal Head
Mouse Data Cable
Mouse to PC Mouse port
1.8M
Shielded, Un-detachable
Metal Head
USB Keyboard Data Cable
USB Keyboard to PC USB port
1.8M
Shielded, Undetachable
Metal Head
International Standards Laboratory
Report Number: ISL-04LR018E489
HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-7-
2.5 Description of Equipment Under Test (EUT) Description: Model No.: FCC ID: Brand: Frequency Range 802.11a: Frequency Range 802.11b/g: Support channel: 802.11a 802.11b/g Modulation Skill: 802.11a Normal mode 802.11b 802.11g
WLAN a+b+g Mini- PCI module CM9 NKRCM9 Wistron NeWeb 5150~5350 MHz, 5470~5725 MHz 2400~2483.5 MHz 19 Channels 13 Channels OFDM (6 Mbps – 54 Mbps) DBPSK(1Mbps), DQPSK(2Mbps), CCK(5.5/11Mbps) OFDM (6M - 54Mbps)
Antennas Type: Antenna 1: PIFA Antenna 2: Dipole Antenna 3: Dipole Antenna 4: Dipole Antenna 5: Dipole Antenna 6: Dipole Antenna 7: Dipole Antenna 8: Dipole Antenna Connected:
( DMA , made by Wistron NeWeb) (GA30038-YMSE , made by GigaAnt Co.) (FCF-004 , made by Long-Chu Co.) (DBA-IPEX-01 , made by Long-Chu Co.) (SRSM5150MRA;SRSM2400MRA , made by CUSLICRAFT ) (DBA-BSMA-01 , made by Long-Chu Co.) (DBA-SSMA-01, made by Long-Chu Co.) (DBA-IPEX-02 , made by Long-Chu Co.) The antenna is connected to the RF connector of the WLAN adapter.
Antenna peak Gain: Antenna 1: Antenna 2: Antenna 3: Antenna 4: Antenna 5: Antenna 6: Antenna 7: Antenna 8:
2.68 dBi (11b/g) ,4.87 dBi(11a) 2.40 dBi (11b/g) ,5.90 dBi(11a) 4.00 dBi (11b/g) ,3.50 dBi(11a) 1.89 dBi (11b/g) ,3.11 dBi(11a) 2.00 dBi (11b/g) ,2.00 dBi(11a) 1.34 dBi (11b/g) ,1.65 dBi(11a) 1.29 dBi (11b/g) ,2.06 dBi(11a) 2.91 dBi (11b/g) ,3.19 dBi(11a)
WLAN Power Type :
3.3V DC from the EUT
International Standards Laboratory
Report Number: ISL-04LR018E489
HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-8The channel and the operation frequency of 802.11b and 802.11g is listed below: Channel Frequency(MHz) Channel Frequency(MHz) 01 2412 07 2442 02 2417 08 2447 03 2422 09 2452 04 2427 10 2457 05 2432 11 2462 06 2437 12 2467 13 2472 The channel and the operation frequency of 802.11a Normal Mode is listed below: Channel Frequency(MHz) Channel Frequency(MHz) 01 5180 11 5540 02 5200 12 5560 03 5220 13 5580 04 5240 14 5600 05 5260 15 5620 06 5280 16 5640 07 5300 17 5660 08 5320 18 5680 09 5500 19 5700 10 5520 During the test, the EUT was tested as a modular device of a notebook PC using a PCMCIA extender board to extend the EUT outside the notebook PC enclosure. There are eight antennas in the EUT: Antenna 1 is PIFA type. Antenna 2 is Dipole in printed type. Antenna 3, 5,6,7 are Dipole type in reverse SMA connector. Antenna 4,8 are Dipole type in hirose connector. All antennas have been tested. The worse data of each type are shown, so, four sets of radiated data are listed in the test report.
International Standards Laboratory
Report Number: ISL-04LR018E489
HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-93.
Electrostatic discharge (ESD) immunity
3.1 Electrostatic discharge (ESD) immunity test
Port: Basic Standard:
Enclosure EN61000-4-2/ AS/NZS 61000.4.2 (details referred to Sec 2.2) Air +/- 2 kV, +/- 4 kV, +/- 8 kV Contact +/-1kV, +/- 2 kV, +/- 4 kV B refer to ISL QA T04-S03 21 degree C 51%
Test Level: Criteria: Test Procedure Temperature: Humidity: Selected Test Point
Air:
discharges were applied to slots, aperture or insulating surfaces. 10 single air discharges were applied to each selected points.
Contact: Total 200 point minimum were to the selected contact points. Indirect Contact Points: 25 discharges were applied to center of each edge of VCP and each EUT side of HCP with 10 cm away from EUT.
International Standards Laboratory
Report Number: ISL-04LR018E489
HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-10Test Setup
EUT is 1m from the wall and other metallic structure. When Battery test mode is needed, a cable with one 470KΩ resister at two rare ends is connected from metallic part of EUT and screwed to HCP.
10cm VCP: 0.5m x 0.5m
For battery test mode 470K
EUT
0.5mm insulation HCP: 1.6m x 0.8m Non-Metallic Table
80cm 470KΩ
470KΩ
Ground reference Plane
Test Result Performance of EUT complies with the given specification.
International Standards Laboratory
Report Number: ISL-04LR018E489
HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-114.
Radio-Frequency, Electromagnetic Field immunity
4.1 Radio-Frequency, Electromagnetic Field immunity test
Port: Basic Standard: Test Level:: Modulation: Frequency range:
Enclosure EN61000-4-3/ AS/NZS 61000.4.3 (details referred to Sec 2.2) 3 V/m AM 1KHz 80% 80 MHz~1 GHz 1400MHz~ 2000MHz
Frequency Step: Step time: Polarization: EUT Azimuth Angle Criteria: Test Procedure Temperature: Humidity:
1% of last step frequency 800 ms Vertical and Horizontal þ 0° þ 90° þ 180° þ 270° A refer to ISL QA T04-S017 21 degree C 44%
Test Setup The field sensor is placed at one calibration grid point to check the intensity of the established fields on both polarizations. EUT is adjusted to have each side of EUT face coincident with the calibration plane. A CCD camera and speakers are used to monitor the condition of EUT for the performance judgment.
Test Result Performance of EUT complies with the given specification. International Standards Laboratory Report Number: ISL-04LR018E489 HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-125.
Electrical Fast transients/burst immunity
5.1 Electrical Fast transient/burst immunity test
Port: Basic Standard:
AC mains; Twisted Pair LAN Port EN61000-4-4/ AS/NZS 61000.4.4 (details referred to Sec 2.2) AC Power Port: +/- 1 kV
Test Level:
Twisted Pair LAN Port: +/- 0.5 kV
Rise Time: Hold Time: Repetition Frequency: Criteria: Test Procedure Temperature: Humidity:
5ns 50ns 5KHz B refer to ISL QA T04-S05 21 degree C 51%
Test Procedure The EUT was setup on a nonconductive table 0.8 m above a reference ground plane. Test Points Line Neutral Ground Line to Neutral Line to Ground Neutral to Ground Line to Neutral to Ground
Polarity + + + + + + + -
Result N N N N N N N N N N N N N N
Comment 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec
Note: ’N’ means normal, the EUT function is correct during the test.
International Standards Laboratory
Report Number: ISL-04LR018E489
HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-13Test Setup EUT is at least 50cm from the conductive structure . AC main: L3cm
0.1 m support
Reference Ground Plane
Test Result Performance of EUT complies with the given specification.
International Standards Laboratory
Report Number: ISL-04LR018E489
HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-16-
8.
Power Frequency Magnetic Field immunity
8.1 Power Frequency Magnetic field immunity test
Port: Basic Standard:
Enclosure EN61000-4-8/ AS/NZS 61000.4.8 (details referred to Sec 2.2) 1A/m X, Y, Z A refer to ISL QA T04-S02 21 degree C 51%
Test Level: Polarization: Criteria: Test Procedure Temperature: Humidity: Test Setup 95% for 5000ms C 0°; 180° 3 times with 10s each 21 degree C 51%
Test Level: Criteria: Test Level: Criteria: Test Level: Criteria: Phase: Test intervals: Temperature: Humidity:
Test Setup EUT AC supply EUT
To AE
Non-Metallic Table To AC main
80cm Test Generator
Ground Reference Plane
Test Result Performance of EUT complies with the given specification.
International Standards Laboratory
Report Number: ISL-04LR018E489
HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997
-1810.
Harmonics
10.1 Harmonics test
Port: Active Input Power:
Basic Standard:
AC mains