CE MARK TECHNICAL FILE

16 downloads 153580 Views 1MB Size Report
CE MARK TECHNICAL FILE of. WLAN a+b+g mini-PCI Module. Model. CM9. Contains: 1. Declaration of Conformity. 2. ETSI EN300 328 or/& ETSI EN301 893  ...
CE MARK TECHNICAL FILE

of

WLAN a+b+g mini-PCI Module

Model

CM9 Contains: 1. Declaration of Conformity 2. ETSI EN300 328 or/& ETSI EN301 893 test report 3. ETSI EN301 489-1 and ETSI EN301 489-17 4. EN61000-3-2/AS/NZS 61000.3.2 test report 5. EN61000-3-3/AS/NZS 61000.3.3 test report 6. Block Diagram and Schematics 7. User`s manual

Wistron Neweb Corporation No. 10-1, Li-hsin Road 1, Science-based Industrial Park,Hsinchu 300, Taiwan, R. O. C. Tel: 886-3-666-7799 Fax: 886-3-666-1654 Page 1 of 2

Declaration of Conformity Name of Manufacturer: Address of Manufacturer: Declares that product: Model:

Wistron NeWeb Corporation No. 10-1, Li-Hsin Road I, Science-based Industrial Park Hsinchu 300, Taiwan, R. O. C. WLAN a+b+g mini-PCI Module CM9

Assembled by: Address:

Same as above Same as above

Conformed to the EMC Directive 99/5/EC as attested by conformity with the following harmonized standards: ETSI EN300 328-2 V1.2.1: ERM; wideband transmission systems; data transmission equipment operating in the 2.4Ghz ISM band and using spread spectrum modulation techniques. ETSI EN301 893 V1.2.1: BRAN; 5Ghz high performance RLAN. ETSI EN301 489-1 V1.2.1 and ETSI EN301 489-17 V1.2.1: ERM; EMC standard for radio equipment and service; specific conditions for wideband data and HIPERLAN equipment. Standard

Description

Results

Criteria

EN61000-4-2: 1995/A1: 1998/A2: 2001 AS/NZS 61000.4.2: 2002

Electrostatic Discharge

Pass

B

EN61000-4-3: 1996/A1: 1998/A2: 2001 AS/NZS 61000.4.3: 1999

Radio-Frequency, Electromagnetic Field

Pass

A

EN61000-4-4: 1995/A1: 2001/A2: 2001 AS/NZS 61000.4.4: 1999

Electrical Fast Transient/Burst

Pass

B

EN61000-4-5: 1995/A1: 2001 AS/NZS 61000.4.5: 1999

Surge

Pass

B

EN61000-4-6: 1996/A1: 2001 AS/NZS 61000.4.6: 1999

Conductive Disturbance

Pass

A

EN61000-4-8: 1993/A1: 2001 AS/NZS 61000.4.8: 2002

Power Frequency Magnetic Field

N/A

A

EN61000-4-11: 1994/A1: 2001 AS/NZS 61000.4.11: 1999

Voltage Dips / Short Interruption and Voltage Variation 30% in 10ms

Pass

B

60% in 100ms

Pass

C

>95% in 5000ms

Pass

C



Wistron Neweb Corporation No. 10-1, Li-hsin Road 1, Science-based Industrial Park,Hsinchu 300, Taiwan, R. O. C. Tel: 886-3-666-7799 Fax: 886-3-666-1654

Page 2 of 2

Standard

Description

Results

EN61000-3-2: 2000 AS/NZS 61000.3.2: 2003

Limits for harmonics current emissions

Pass

EN61000-3-3: 1995 A1: 2001/ AS/NZS 61000.3.3: 1998

Limits for voltage fluctuations and flicker in low-voltage supply systems .

Pass

We, Wistron NeWeb Corporation, hereby declare that the equipment bearing the trade name and model number specified above was tested conforming to the applicable Rules under the most accurate measurement standards possible, and that all the necessary steps have been taken and are in force to assure that production units of the same equipment will continue to comply with the requirements.

---------------------------

Edward Yeh/ Engineer Wistron NeWeb Corporation Date: 2004/06/04

No. 65, Ku Dai Keng St., Hsichih, Taipei 221, R.O. C. Tel: 886-2-2646-2550 FAX: 886-2-26464641 No. 120, Lane 180, San Ho Tsuen, Hsin Ho Rd. Lung-Tan Hsiang, Tao Yuan County 325, Taiwan, R.O.C. Tel: 886-3-407-1718 FAX:886-3-407-1738

Product Name: Model Number(s):

WLAN a+b+g mini-PCI Module

Responsible Party Address:

Wistron Neweb Corporation No. 10-1, Li-hsin Road 1, Science-based Industrial Park,Hsinchu 300, Taiwan, R. O. C. Edward Yeh

Contact Person:

CM9

Issue Date: 2004/06/04 Test Report No.: 04LR018E489

We, International Standards Laboratory, hereby certify that: The device bearing the trade name and model specified above has been shown to comply with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in EMC Directive 99/5/EC. The device was passed the test performed according to : ETSI EN300 328-2 V1.2.1: ERM; wideband transmission systems; data transmission equipment operating in the 2.4Ghz ISM band and using spread spectrum modulation techniques. ETSI EN301 893 V1.2.1: BRAN; 5Ghz high performance RLAN. ETSI EN301 489-1 V1.2.1 and ETSI EN301 489-17 V1.2.1: ERM; EMC standard for radio equipment and service; specific conditions for wideband data and HIPERLAN equipment. EN61000-4-2: 1995/A1: 1998/A2: 2001 AS/NZS 61000.4.2: 2002

EN61000-4-6: 1996/A1: 2001 AS/NZS 61000.4.6: 1999

EN61000-4-3: 1996/A1: 1998/A2: 2001 AS/NZS 61000.4.3: 1999

EN61000-4-8: 1993/A1: 2001 AS/NZS 61000.4.8: 2002

EN61000-4-4: 1995/A1: 2001/A2: 2001 AS/NZS 61000.4.4: 1999

EN61000-4-11: 1994/A1: 2001 AS/NZS 61000.4.11: 1999

EN61000-4-5: 1995/A1: 2001 AS/NZS 61000.4.5: 1999

EN61000-3-2: 2000/AS/NZS 61000.3.2: 2003: Limits for harmonics current emissions. EN61000-3-3: 1995/A1: 2001/ AS/NZS 61000.3.3: 1998: Limits for voltage fluctuations and flicker in low-voltage supply systems. I attest to the accuracy of data and all measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them.

--------------------------------------Eddy Hsiung/Director International Standards Laboratory

EN55024 / AS/NZS CISPR 24 / IMMUNITY ETSI EN 301 489-1 & ETSI EN 301 489-17 EN61000-3-2 / HARMONICS EN61000-3-3 / VOLTAGE FLUCTUATIONS TEST REPORT of

WLAN a+b+g mini-PCI Module

Model

CM9 (Brand: Wistron NeWeb)

Applied by: Wistron NeWeb Corporation No. 10-1, Li-Hsin Road I, Science-based Industrial Park Hsinchu 300, Taiwan, R. O. C. Test Performed by: (NVLAP Lab. Code: 200234-0) International Standards Laboratory No. 120, Lane 180, San Ho Tsuen, Hsin Ho Rd. Lung-Tan Hsiang, Tao Yuan County 325 Taiwan, R.O.C. Tel:(03)407-1718 Fax:(03)407-1738

Report Number: ISL-04LR018E489

Test Date: 2004/06/04

HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997 T10-R1-10

-iContents of Report 1.

General.............................................................................................................................. 1 Certification of Accuracy of Test Data............................................................................. 1 2. Summary........................................................................................................................... 2 2.1 Applicant Information...................................................................................................... 2 2.2 Test Standards................................................................................................................ 2 2.3 Operation Environment ................................................................................................... 2 2.4 Description of Support Equipment................................................................................... 3 2.4.1 Software for Controlling Support Unit....................................................................... 5 2.4.2 I/O Cable Condition of EUT and Support Units........................................................ 6 2.5 Description of Equipment Under Test (EUT) ................................................................... 7 3. Electrostatic discharge (ESD) immunity............................................................................... 9 3.1 Electrostatic discharge (ESD) immunity test ..................................................................... 9 4. Radio-Frequency, Electromagnetic Field immunity............................................................ 11 4.1 Radio-Frequency, Electromagnetic Field immunity test................................................... 11 5. Electrical Fast transients/burst immunity............................................................................. 12 5.1 Electrical Fast transient/burst immunity test..................................................................... 12 6. Surge Immunity................................................................................................................ 14 6.1 Surge immunity test....................................................................................................... 14 7. Immunity to Conductive Disturbance................................................................................. 15 7.1 Immunity to Conductive Disturbance ............................................................................. 15 8. Power Frequency Magnetic Field immunity....................................................................... 16 8.1 Power Frequency Magnetic field immunity test............................................................... 16 9. Voltage Dips, Short Interruption and Voltage Variation immunity....................................... 17 9.1 Voltage Dips, Short Interruption and Voltage Variation immunity test ............................. 17 10. Harmonics ....................................................................................................................... 18 10.1 Harmonics test .......................................................................................................... 18 11. Voltage Fluctuations......................................................................................................... 21 11.1 Voltage Fluctuations test............................................................................................ 21 12. Test Equipment List.......................................................................................................... 23 12.1 Software for Controlling Spectrum/Receiver and Calculating Test Data....................... 24 13. Photographs..................................................................................................................... 25 13.1 Photos of ESD measurement ..................................................................................... 25 13.2 Photos of RF Field Strength Susceptibility Measurement ............................................ 25 13.3 Photos of Electrical Fast Transient/Burst measurement................................................ 26 13.4 Photos of Surge measurement.................................................................................... 26 13.5 Photo of Conductive Measurement ............................................................................ 27 13.6 Photo of Magnetic field measurement......................................................................... 27 13.7 Photos of Voltage Dips measurement......................................................................... 28 13.8 Photos of Harmonics and Voltage Fluctuations........................................................... 28 13.9 Appendix: Photographs of EUT................................................................................. 29 1.1

International Standards Laboratory

Report Number: ISL-04LR018E489

HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997

-11.

General

1.1 Certification of Accuracy of Test Data The immunity tests which this report describes were conducted by an independent electromagnetic compatibility consultant, International Standards Laboratory in accordance with the EN55024: 1998/A1:2001 / ETSI EN301 489-1 (2001-09), ETSI EN301 489-17 (2001-09) / AS/NZS CISPR 24:

1997 which include EN61000-4 series regulations, Harmonic Current Emissions EN61000-3-2: 2000 / AS/NZS 61000.3.2: 2003, and Voltage Fluctuations EN61000-3-3: 1995/A1: 2001 / AS/NZS 61000.3.3: 1998. Equipment Tested: WLAN a+b+g mini-PCI Module Model: CM9 Applied by Wistron NeWeb Corporation Date of test:

2004/06/03

Test Site:

LT Test Site

Test Engineer:

Jerry Chiou

Approve & Signature

---------------------------------------------

Eddy Hsiung/Director Test results given in this report apply only to the specific sample(s) tested under stated test conditions. This report shall not be reproduced other than in full without the explicit written consent of ISL. This report totally contains 31 pages, including 1 cover page , 1 contents page, and 29 pages for the test description. This report must not be use to claim product endorsement by NVLA, NIST, any agency of the federal government. This test report accurately contains the test results of the above standards at the time of the test. The results in this report apply only to the sample(s) tested. This test report shall not be reproduced except in full, without the written approval of International Standards Laboratory.

International Standards Laboratory

Report Number: ISL-04LR018E489

HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997

-22.

Summary

2.1 Applicant Information Applicant:

Wistron NeWeb Corporation No. 10-1, Li-Hsin Road I, Science-based Industrial Park Hsinchu 300, Taiwan, R. O. C.

2.2 Test Standards

ETSI EN301 489-1 V1.2.1 and ETSI EN301 489-17 V1.2.1: ERM; EMC standard for radio equipment and service; specific conditions for wideband data and HIPERLAN equipment. Standard

Description

Results

Criteria

EN61000-4-2: 1995/A1: 1998/A2: 2001 AS/NZS 61000.4.2: 2002

Electrostatic Discharge

Pass

B

EN61000-4-3: 1996/A1: 1998/A2: 2001 AS/NZS 61000.4.3: 1999

Radio-Frequency, Electromagnetic Field

Pass

A

EN61000-4-4: 1995/A1: 2001/A2: 2001 AS/NZS 61000.4.4: 1999

Electrical Fast Transient/Burst

Pass

B

EN61000-4-5: 1995/A1: 2001 AS/NZS 61000.4.5: 1999

Surge

Pass

B

EN61000-4-6: 1996/A1: 2001 AS/NZS 61000.4.6: 1999

Conductive Disturbance

Pass

A

EN61000-4-8: 1993/A1: 2001 AS/NZS 61000.4.8: 2002

Power Frequency Magnetic Field

N/A

A

EN61000-4-11: 1994/A1: 2001 AS/NZS 61000.4.11: 1999

Voltage Dips / Short Interruption and Voltage Variation 30% in 10ms

Pass

B

60% in 100ms

Pass

C

>95% in 5000ms

Pass

C

Standard

Description

Results

EN61000-3-2: 2000 AS/NZS 61000.3.2: 2003

Limits for harmonics current emissions

Pass

EN61000-3-3: 1995 A1: 2001/ AS/NZS 61000.3.3: 1998

Limits for voltage fluctuations and flicker in low-voltage supply systems .

Pass

2.3 Operation Environment Power supply : AC 230 V / 50 Hz

International Standards Laboratory

Report Number: ISL-04LR018E489

HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997

-32.4 Description of Support Equipment

Support Unit 1. Description: Model Number: Serial Number: Power Supply Type: Power Cord: FCC ID:

Acer USB Keyboard 6511-UV N/A N/A N/A N/A (comply with FCC DOC)

Support Unit 2. Description: Model Number: Serial Number: Power Supply Type: Power Cord: FCC ID:

DELL USB Mouse M-UR69 LNA24412741 N/A N/A N/A (Comply with FCC DOC)

Support Unit 3. Description: Model: Serial Number: Power Cord: FCC ID:

Acer Monitor G781 999007101214400445T7AA31T Non-shielded, Detachable (Comply with FCC Standards)

Support Unit 4. Description: Model Number: Serial Number: Power Supply Type: Power Cord: Data Cable: FCC ID:

International Standards Laboratory

HP Printer (for parallel interface port) C2642A TH84T1N3J3 AC Adaptor (HP Model: C2175A) Non-shielded, Detachable Shielded, Detachable, With Metal Hood B94C2642X

Report Number: ISL-04LR018E489

HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997

-4-

Support Unit 5. Description: Model No.: Brand: AC Power Adapter Manufacturer: HDD: Modem Card: FDD: SDRAM: 1394 C0nnector: USB Connector: RJ11 Connector: RJ45 Connector: VGA Connector: PCMCIA Slot Line out Port: Line-in Port: Parallel Port DC IN Port: Battery: LCD: CPU

International Standards Laboratory

Notebook Personal Computer Aspire1510,ZP2,ZP2A acer LSE(Model:ADP-90FB REV:F) HGST (Model: IC25N030ATMR04-0) Ambit (Model: T60M283.10) Panasonic (Model:UJ-266A343FC) Infineon (Model:HYS64D32020GDL-6-B) one 4 Pins four 4 Pins one 2 Pins one 8 Pins one 15 Pins one one one one 25pins one Li-ION DC14.8V 4400mAh QSI (Model:QD150XL06-01) AMD Athlon 64 2800+

Report Number: ISL-04LR018E489

HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997

-5-

2.4.1 Software for Controlling Support Unit Test programs exercising various part of EUT were used. The programs were executed as follows: A. Read and write to the disk drives. B. Send H pattern to the video port device (Monitor). C. Send H pattern to the parallel port device (Printer). D. Repeat the above steps.

Filename

Issued Date

Printer1

Wordpad.exe

11/11/1999

Monitor

HH.bat

8/20/1991

International Standards Laboratory

Report Number: ISL-04LR018E489

HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997

-62.4.2 I/O Cable Condition of EUT and Support Units

Description

Path

Cable Length

Cable Type

Connector Type

AC Power Cord

110V (~240V) to AC Power Cord Inlet (3-pin)

1.8M

Nonshielded, Detachable

Plastic Head

Printer Data Cable

Printer to PC Parallel port

1.5M

Shielded, Detachable

Metal Head

Monitor Data Cable

Monitor to PC VGA port

1.6M

Shielded, Un-detachable

Metal Head

Mouse Data Cable

Mouse to PC Mouse port

1.8M

Shielded, Un-detachable

Metal Head

USB Keyboard Data Cable

USB Keyboard to PC USB port

1.8M

Shielded, Undetachable

Metal Head

International Standards Laboratory

Report Number: ISL-04LR018E489

HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997

-7-

2.5 Description of Equipment Under Test (EUT) Description: Model No.: FCC ID: Brand: Frequency Range 802.11a: Frequency Range 802.11b/g: Support channel: 802.11a 802.11b/g Modulation Skill: 802.11a Normal mode 802.11b 802.11g

WLAN a+b+g Mini- PCI module CM9 NKRCM9 Wistron NeWeb 5150~5350 MHz, 5470~5725 MHz 2400~2483.5 MHz 19 Channels 13 Channels OFDM (6 Mbps – 54 Mbps) DBPSK(1Mbps), DQPSK(2Mbps), CCK(5.5/11Mbps) OFDM (6M - 54Mbps)

Antennas Type: Antenna 1: PIFA Antenna 2: Dipole Antenna 3: Dipole Antenna 4: Dipole Antenna 5: Dipole Antenna 6: Dipole Antenna 7: Dipole Antenna 8: Dipole Antenna Connected:

( DMA , made by Wistron NeWeb) (GA30038-YMSE , made by GigaAnt Co.) (FCF-004 , made by Long-Chu Co.) (DBA-IPEX-01 , made by Long-Chu Co.) (SRSM5150MRA;SRSM2400MRA , made by CUSLICRAFT ) (DBA-BSMA-01 , made by Long-Chu Co.) (DBA-SSMA-01, made by Long-Chu Co.) (DBA-IPEX-02 , made by Long-Chu Co.) The antenna is connected to the RF connector of the WLAN adapter.

Antenna peak Gain: Antenna 1: Antenna 2: Antenna 3: Antenna 4: Antenna 5: Antenna 6: Antenna 7: Antenna 8:

2.68 dBi (11b/g) ,4.87 dBi(11a) 2.40 dBi (11b/g) ,5.90 dBi(11a) 4.00 dBi (11b/g) ,3.50 dBi(11a) 1.89 dBi (11b/g) ,3.11 dBi(11a) 2.00 dBi (11b/g) ,2.00 dBi(11a) 1.34 dBi (11b/g) ,1.65 dBi(11a) 1.29 dBi (11b/g) ,2.06 dBi(11a) 2.91 dBi (11b/g) ,3.19 dBi(11a)

WLAN Power Type :

3.3V DC from the EUT

International Standards Laboratory

Report Number: ISL-04LR018E489

HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997

-8The channel and the operation frequency of 802.11b and 802.11g is listed below: Channel Frequency(MHz) Channel Frequency(MHz) 01 2412 07 2442 02 2417 08 2447 03 2422 09 2452 04 2427 10 2457 05 2432 11 2462 06 2437 12 2467 13 2472 The channel and the operation frequency of 802.11a Normal Mode is listed below: Channel Frequency(MHz) Channel Frequency(MHz) 01 5180 11 5540 02 5200 12 5560 03 5220 13 5580 04 5240 14 5600 05 5260 15 5620 06 5280 16 5640 07 5300 17 5660 08 5320 18 5680 09 5500 19 5700 10 5520 During the test, the EUT was tested as a modular device of a notebook PC using a PCMCIA extender board to extend the EUT outside the notebook PC enclosure. There are eight antennas in the EUT: Antenna 1 is PIFA type. Antenna 2 is Dipole in printed type. Antenna 3, 5,6,7 are Dipole type in reverse SMA connector. Antenna 4,8 are Dipole type in hirose connector. All antennas have been tested. The worse data of each type are shown, so, four sets of radiated data are listed in the test report.

International Standards Laboratory

Report Number: ISL-04LR018E489

HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997

-93.

Electrostatic discharge (ESD) immunity

3.1 Electrostatic discharge (ESD) immunity test

Port: Basic Standard:

Enclosure EN61000-4-2/ AS/NZS 61000.4.2 (details referred to Sec 2.2) Air +/- 2 kV, +/- 4 kV, +/- 8 kV Contact +/-1kV, +/- 2 kV, +/- 4 kV B refer to ISL QA T04-S03 21 degree C 51%

Test Level: Criteria: Test Procedure Temperature: Humidity: Selected Test Point

Air:

discharges were applied to slots, aperture or insulating surfaces. 10 single air discharges were applied to each selected points.

Contact: Total 200 point minimum were to the selected contact points. Indirect Contact Points: 25 discharges were applied to center of each edge of VCP and each EUT side of HCP with 10 cm away from EUT.

International Standards Laboratory

Report Number: ISL-04LR018E489

HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997

-10Test Setup

EUT is 1m from the wall and other metallic structure. When Battery test mode is needed, a cable with one 470KΩ resister at two rare ends is connected from metallic part of EUT and screwed to HCP.

10cm VCP: 0.5m x 0.5m

For battery test mode 470K

EUT

0.5mm insulation HCP: 1.6m x 0.8m Non-Metallic Table

80cm 470KΩ

470KΩ

Ground reference Plane

Test Result Performance of EUT complies with the given specification.

International Standards Laboratory

Report Number: ISL-04LR018E489

HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997

-114.

Radio-Frequency, Electromagnetic Field immunity

4.1 Radio-Frequency, Electromagnetic Field immunity test

Port: Basic Standard: Test Level:: Modulation: Frequency range:

Enclosure EN61000-4-3/ AS/NZS 61000.4.3 (details referred to Sec 2.2) 3 V/m AM 1KHz 80% 80 MHz~1 GHz 1400MHz~ 2000MHz

Frequency Step: Step time: Polarization: EUT Azimuth Angle Criteria: Test Procedure Temperature: Humidity:

1% of last step frequency 800 ms Vertical and Horizontal þ 0° þ 90° þ 180° þ 270° A refer to ISL QA T04-S017 21 degree C 44%

Test Setup The field sensor is placed at one calibration grid point to check the intensity of the established fields on both polarizations. EUT is adjusted to have each side of EUT face coincident with the calibration plane. A CCD camera and speakers are used to monitor the condition of EUT for the performance judgment.

Test Result Performance of EUT complies with the given specification. International Standards Laboratory Report Number: ISL-04LR018E489 HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997

-125.

Electrical Fast transients/burst immunity

5.1 Electrical Fast transient/burst immunity test

Port: Basic Standard:

AC mains; Twisted Pair LAN Port EN61000-4-4/ AS/NZS 61000.4.4 (details referred to Sec 2.2) AC Power Port: +/- 1 kV

Test Level:

Twisted Pair LAN Port: +/- 0.5 kV

Rise Time: Hold Time: Repetition Frequency: Criteria: Test Procedure Temperature: Humidity:

5ns 50ns 5KHz B refer to ISL QA T04-S05 21 degree C 51%

Test Procedure The EUT was setup on a nonconductive table 0.8 m above a reference ground plane. Test Points Line Neutral Ground Line to Neutral Line to Ground Neutral to Ground Line to Neutral to Ground

Polarity + + + + + + + -

Result N N N N N N N N N N N N N N

Comment 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec 60 sec

Note: ’N’ means normal, the EUT function is correct during the test.

International Standards Laboratory

Report Number: ISL-04LR018E489

HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997

-13Test Setup EUT is at least 50cm from the conductive structure . AC main: L3cm

0.1 m support

Reference Ground Plane

Test Result Performance of EUT complies with the given specification.

International Standards Laboratory

Report Number: ISL-04LR018E489

HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997

-16-

8.

Power Frequency Magnetic Field immunity

8.1 Power Frequency Magnetic field immunity test

Port: Basic Standard:

Enclosure EN61000-4-8/ AS/NZS 61000.4.8 (details referred to Sec 2.2) 1A/m X, Y, Z A refer to ISL QA T04-S02 21 degree C 51%

Test Level: Polarization: Criteria: Test Procedure Temperature: Humidity: Test Setup 95% for 5000ms C 0°; 180° 3 times with 10s each 21 degree C 51%

Test Level: Criteria: Test Level: Criteria: Test Level: Criteria: Phase: Test intervals: Temperature: Humidity:

Test Setup EUT AC supply EUT

To AE

Non-Metallic Table To AC main

80cm Test Generator

Ground Reference Plane

Test Result Performance of EUT complies with the given specification.

International Standards Laboratory

Report Number: ISL-04LR018E489

HC LAB :NVLAP:200234-0;VCCI: R-341,C-354;NEMKO:ELA 113a,113c;BSMI:SL2-IN-E-0037;SL2-R1-E-0037;CNLA:1178 LT LAB:NVLAP:200234-0;VCCI: R-1435,C-1440;NEMKO:ELA 113b,113d;BSMI:SL2-IN-E-0013;CNLA:0997

-1810.

Harmonics

10.1 Harmonics test

Port: Active Input Power:

Basic Standard:

AC mains