Heating. Nom. m³/min. 48.0. 83. Sound power level Cooling. dBA. 65. 70. 71. 70. 71. Sound pressure level. Cooling. Nom.
Siesta
Sky Air COMMERCIAL CATALOGUE
About
Daikin
Daikin has a worldwide reputation based on over
90 years’ experience in the successful manufacture of high quality heating, ventilation, air conditioning and refrigeration equipment for industrial, commercial and residential use and 55 years as leader in heat pump technology.
2
Daikin quality Daikin’s much envied quality quite simply stems from the close attention paid to design, production and testing as well as aftersales support. To this end, every component is carefully selected and rigorously tested to verify its contribution to product quality and reliability.
Environmental awareness Air conditioning enhances the indoor climate, providing pleasant
the market. Similarly, advanced computerised control packages
working and living conditions in even the harshest climates.
ensure optimum system efficiency at all times and allow remote
In recent years however, aware of the need to safeguard
monitoring via the internet.
the environment, Daikin has taken great strides to limit
Reducing waste
negative effects associated with its production and operation.
Daikin was the first European air conditioning manufacturer to
As a result, new energy saving equipment combined with
gain ISO14001 environmental certification. The company’s zero
innovative manufacturing techniques, minimise any impact on
waste policy ensures that many of its manufacturing by products
the environment.
can be recycled, reused or recovered.
Commitment to the environment
Recycling materials
Concern for the environment is inherent throughout Daikin’s
Daikin recycles materials as a matter of course. For instance,
global operations, from design and production to the everyday
the sludge recovered from pre treated waste water is used in
actions of its workforce. Daikin heat pumps in combination with
cement manufacture. The recycling of other types of waste is also
in-house inverter technology offer unparallelled indoor heating
supported by investment in returnable packaging.
comfort and process efficiency.
Daikin leading the way to seasonal efficiency
Heat pump efficiency
Seasonal efficiency is a measure mandated by the European
Heat pumps can extract heat energy from the outside air, even on
Union to optimise energy consumption. The EU wants to make
the coldest days of winter. Daikin systems are capable of providing
people aware of what units are consuming and ban non-efficient
comfortable and efficient indoor heating as well as meeting exact
products from the market. Seasonal efficient units reflect the
industrial heating and cooling requirements.
actual performance you can expect over an entire heating and
Energy efficient equipment
cooling season. The standard came into force in January 2013 for
Many product innovations stem from Daikin environmental
products under 12kW.
awareness. Inverter control reduces unit start up time and varies
Today, Daikin is leading the way towards more efficient and cost-
compressor output to match precise system load requirements.
effective comfort solutions. All Daikin products - residential and
Also, when linked with Daikin DC compressor motors, it allows
commercial as well as industrial - are seasonal efficient, they all
Daikin equipment to achieve the highest COP ratings in
reduce energy and costs in a smart way.
3
Why choose Daikin? Cutting edge technology For the last 50 years, Daikin has been the market leader in cutting-edge climate control technology that is both energy efficient and eco-friendly. Our systems have been independently tested against the latest and most demanding energy and ecological standards and our heat pump systems were the first to receive the EU’s Eco-Label.
3/4 Renewable
ambient air
As your partner of choice for the installation and maintenance of flexible, trouble-free and costeffective climate control solutions, we have a global network of engineers providing local
ser vice . B y installing Daikin equipment you can be assured that you have very energy efficient units with a low ecological impact thus saving you money and helping the environment.
Heat pump Air-to-air heat pumps obtain 75% of their output energy from a renewable source: the ambient air, which is both renewable and inexhaustible*.
1/4 Electrical energy
Of course, heat pumps also require electricity to run the system, but increasingly this electricity can also be generated from renewable energy sources such as solar energy, wind energy, hydropower and biomass. A heat pump’s efficiency is measured in COP (Coefficient Of Performance) for heating and EER (Energy Efficiency Ratio) for cooling. * EU objective COM (2008)/30
Heat pump system:
compared to
COP 3.61*
Traditional electrical heating system: COP
3/4 kW 3/4 kW + + 3/4 kW 1/4 kW 4/4 kW1/4 kW+ 1 600mm
1
Radiateur standard basse température
0.75 kW
renewable energy (air)
+
3/4 kW +1 kW energy
0.25 kW
1/4 kW
1/4 kW 700mm 4
2000mm
4/4 kW 4/4 kW 600mm
4/4 1 kW Console Daikin
Desired room temperature optimally maintained
22°C
Inverter technology Daikin’s inverter technology is a true innovation in the field of climate control. The principle is simple: inverters adjust the power used to suit the actual requirement - no more, no less! This technology provides you with two main benefits:
1. Optimizing comfort levels The inverter repays its investment many times over by improving comfort. A climate control system with an inverter continuously adjusts its cooling and heating output to suit the temperature in the room, thus improving comfort levels. The inverter reduces system start-up time enabling the required room temperature to be reached more quickly. As soon as the correct
Temperature / Power input
temperature is reached, the inverter ensures that it is
Air conditioning without Inverter
constantly maintained.
Slow start
2. Energy efficiency
Set temp.
Because an inverter monitors and adjusts ambient temperature whenever needed, energy consumpTemperature remains stable
Air conditioning with Inverter
tion drops by 30% compared to a traditional on/off Time
5
(non-inverter) heat pump system!
Overview Indoor units Type
Model Siesta, 4-way blow ceiling mounted cassette
Ceiling mounted cassette
ACQ-C
• for shops requiring maximum floor space and perfect integration • solution for basic cooling and heating
Siesta, concealed ceiling unit
Concealed ceiling
ABQ-C
• for shops requiring maximum floor space and perfect integration • solution for basic cooling and heating
Siesta, ceiling suspended cassette
Ceiling suspended
System
AHQ-C
• for shops with narrow or no false ceiling • solution for basic cooling and heating
Outdoor units
Pair application
Type
Product name AZQS-BV1
• for shop application • basic cooling/heating solution • pair application
AZQS-BY1
Seasonal efficiency gives a more realistic indication on how efficient air conditioners operate over an entire heating or cooling season.
Inverter technology
In combination with inverter controlled outdoor units
Fan only
The air conditioner can be used as fan, blowing air without cooling or heating.
Draught prevention
When starting to warm up or when the thermostat is off, the air discharge direction is set horizontally and the fan to low speed, to prevent draught. After warming up, air discharge and fan speed are set as desired.
Auto cooling-heating changeover
Automatically selects cooling or heating mode to achieve the set temperature.
Air filter
Removes airborne dust particles to ensure a steady supply of clean air.
Ceiling soiling prevention
A special function prevents air blowing out too long in horizontal position, to prevent ceiling stains.
Fan speed steps
Allows to select up to the given number of fan speed.
Weekly timer
Timer can be set to start operation anytime on a daily or weekly basis
Infrared remote control
Infrared remote control with LCD to start, stop and regulate the air conditioner from a distance.
Wired remote control
Wired remote control to start, stop and regulate the air conditioner from a distance.
Auto-restart
The unit restarts automatically at the original settings after power failure.
Self-diagnosis
Simplifies maintenance by indicating system faults or operating anomalies.
Drain pump kit
Facilitates condensation draining from the indoor unit.
Air flow
Air treatment
Comfort
We care icons
Seasonal efficiency - Smart use of energy
Remote control & timer
Heat pump
Model
Other funtions
Air cooled
Product name
INVERTER
6
Capacity (class)
25
35
50
60
71
100
125
140
200
250
Capacity (class)
71
100
125
140
200
250
Ceiling mounted cassette
Concealed ceiling unit
Ceiling suspended unit
ACQ-C
ABQ-C
AHQ-C
4
3
3
standard
standard
optional
standard
optional
standard
7
ACQ-C / AZQS-BV1/BY1
ACQ71C
›› ›› ›› ›› ›› ›› ››
Siesta, 4-way blow ceiling mounted cassette
AZQS71BV1
ARCWLA
Ideal solution for shops, restaurants or offices requiring maximum floor space for furniture, decorations and fittings Air can be discharged in any of 4 directions Air filter removes airborne dust particles to ensure a steady supply of clean air Easy installation and maintenance Control several indoor units at the same time via the Siesta Sky Air group control (optional) Standard drain pump Fresh air intake: up to 20 %
Heating & Cooling INDOOR UNIT Cooling capacity Heating capacity Power input Seasonal efficiency (according to EN14825)
Nominal efficiency (cooling at 35°/27° nominal load, heating at 7°/20° nominal load) Dimensions Weight Decoration panel
Fan - Air flow rate Sound power level Sound pressure level Piping connections Power supply
Min./Nom./Max. Min./Nom./Max. Cooling Nom. Heating Nom. Cooling Energy label Pdesign SEER Annual energy consumption Heating Energy label (Average Pdesign climate) SCOP Annual energy consumption EER COP Annual energy consumption Energy label Cooling/Heating HeightxWidthxDepth Unit Unit Colour HeightxWidthxDepth Dimensions Weight High/Nom./Low/Silent operation Cooling High/Nom./Low/Silent operation Heating Cooling Heating High/Nom./Low/Silent operation Cooling High/Nom./Low/Silent operation Heating Liquid OD Gas OD Phase / Frequency / Voltage
OUTDOOR UNIT Dimensions Unit Weight Unit Fan - Air flow rate Cooling Heating Sound power level Cooling Sound pressure Cooling level Heating Night quiet mode Operation range Cooling Heating Refrigerant Type/GWP Piping Piping length connections
Power supply Current - 50Hz
kW kW kW kW
ACQ71C -/6.8/-/7.50/2.05 2.08
kW
6.80
ACQ71C -/6.8/-/7.50/2.05 2.08
9.50
3.01 3.41 2,010 B/B
6.80
kWh
512
716 A
kW
6.33
7.60 3.80
kWh
2,332 3.31
kWh
1,025 B/A 265x820x820 31
2,800 3.21 3.61
mm kg mm kg m³/min m³/min dBA dBA dBA dBA mm mm Hz / V
m m m m Hz / V A
24.4/20.5/17.6/15.0 24.4/20.5/17.6/15.0 54 54 41/38/35/32 41/38/35/32
AZQS71BV1 770x900x320 67 52.0 48.0 65 48/43 50 -
ACQ100C -/9.5/-/10.8/2.96 2.99
ACQ125C -/12.1/-/13.5/4.02 3.96
9.50
3.01 3.41 2,010 B/B
B
4.65
mm kg Nom. m³/min Nom. m³/min dBA Nom./Silent operation dBA Nom. dBA Level 1 dBA Ambient Min.~Max. °CDB Ambient Min.~Max. °CWB
(1) EER/COP according to Eurovent 2012, for use outside EU only
ACQ125C -/12.1/-/13.5/4.02 3.96
B
HeightxWidthxDepth
OU - IU Max. System Equivalent Level difference IU - OU Max. IU - IU Max. Phase / Frequency / Voltage Maximum fuse amps (MFA)
ACQ100C -/9.5/-/10.80/2.96 2.99
1,480 A/A
4.65 512 6.33
7.60 3.80
2,332 3.31
2,800 3.21 3.61
1,025 B/A 265x820x820 31
300x820x820 39
29.2/24.4/21.0/17.6 29.2/24.4/21.0/17.6 57 56 44/41/38/36 44/41/38/36
716 A
White 82x990x990 4 34.0/29.2/26.3/22.1 24.4/20.5/17.6/15.0 34.0/29.2/26.3/22.1 24.4/20.5/17.6/15.0 60 54 60 54 47/44/43/41 41/38/35/32 47/44/43/41 41/38/35/32 9.52 15.88 1~ / 50 / 220-240
AZQS100BV1
1,480 A/A 300x820x820 39
29.2/24.4/21.0/17.6 29.2/24.4/21.0/17.6 57 56 44/41/38/36 44/41/38/36
AZQS125BV1 AZQS100BY1 990x940x320 81
76
34.0/29.2/26.3/22.1 34.0/29.2/26.3/22.1 60 60 47/44/43/41 47/44/43/41
AZQS125BY1 82
77
76
77
70 53/57
71 54/58
83 70 53/57
71 54/58 49 -5~46 -15~15.5 R-410A/1,975
30 40 15.0 -
50 70 30.0 0.5 1~ / 50 / 220-240
20
3N~ / 50 / 380-415 -
ABQ-C / AZQS-BV1/BY1
ABQ71C
›› ›› ›› ›› ››
Siesta, concealed ceiling unit
AZQS71BV1
ARCW8 (standard)
Ideal solution for shops, requiring maximum floor space for furniture, decorations and fittings Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Air filter removes airborne dust particles to ensure a steady supply of clean air Easy installation and maintenance Double-protection drainage system: primary and secondary drain pan
Heating & Cooling INDOOR UNIT Cooling capacity Heating capacity Power input
Min./Nom./Max. Min./Nom./Max. Cooling Nom. Heating Nom. Seasonal efficiency Cooling Energy label (according to Pdesign EN14825) SEER Annual energy consumption Heating Energy label (Average Pdesign climate) SCOP Annual energy consumption Nominal efficiency EER (cooling at 35°/27° COP nominal load, heating Annual energy consumption at 7°/20° nominal load) Energy label Cooling/Heating HeightxWidthxDepth Dimensions Unit Weight Unit Fan - Air flow rate Cooling High/Nom./Low Heating High/Nom./Low Fan - External static pressure High/Nom./Low Sound power level Cooling Heating Sound pressure Cooling High/Nom./Low level Heating High/Nom./Low Piping Liquid OD connections Gas OD Power supply Phase / Frequency / Voltage OUTDOOR UNIT Dimensions Unit Weight Unit Fan - Air flow rate Cooling Heating Sound power level Cooling Heating Sound pressure Cooling level Heating Night quiet mode Operation range Cooling Heating Refrigerant Type/GWP Piping Piping length connections
Power supply Current - 50Hz
kW kW kW kW
ABQ71C 6.8 -/7.5/2.33 2.13
kW
6.80
kWh
512
ABQ125C 12.1 -/13.5/4.31 3.96
ABQ140C -/13.0/-/15.5/4.32 4.55
B
715 A
kW
5.65
6.78 3.80
kWh
kWh mm kg m³/min m³/min Pa dBA dBA dBA dBA mm mm Hz / V
mm kg Nom. m³/min Nom. m³/min dBA dBA Nom./Silent operation dBA Nom. dBA Level 1 dBA Ambient Min.~Max. °CDB Ambient Min.~Max. °CWB m m m m Hz / V A
2,082 2.91 3.51 1,165 C/B 285x600x1,007 35 18.3/16.8/15.4 18.3/16.8/15.4 90/77/64 64 64 -
AZQS71BV1 770x900x320 67 52.0 48.0 65
2,498 2.62 3.42 1,813 D/B 378x541x1,045 44 22.7/20.5/18.3 22.7/20.5/18.3 70/57/45 60 60 41/38/36 41/38/36
ABQ100C -/9.5/-/10.8/3.63 3.16 B 9.50 4.65 624 A 6.78 3.80 3,500 2.62 3.42 1,813 D/B 378x541x1,045 44 22.7/20.5/18.3 22.7/20.5/18.3 70/57/45 60 60 41/38/36 41/38/36
-
9.50 4.65
HeightxWidthxDepth
OU - IU Max. System Equivalent Level difference IU - OU Max. IU - IU Max. Phase / Frequency / Voltage Maximum fuse amps (MFA)
ABQ100C 9.5 -/10.8/3.63 3.16
2.81
3.01 3.41
2,153 C/B 378x541x1,299 50 40.5/37.4/34.8 40.5/37.4/34.8 150/128/111
2,159 378x541x1,499 56 48.7/43.9/37.9 48.7/43.9/37.9 150/122/92 -
53/52/50 53/52/50
AZQS100BV1 AZQS125BV1 990x940x320 81 76 77 83 70 71
55/53/50 55/53/50 9.52 15.88 1~ / 50 / 220-240 AZQS140BV1 1,430x940x320 102 83 62
ABQ125C -/12.1/-/13.5/4.31 3.96
ABQ140C -/13.0/-/15.5/4.32 4.55 -
2.81
3.01 3.41
2,153 C/B 378x541x1,299 50 40.5/37.4/34.8 40.5/37.4/34.8 150/128/111
2,159 378x541x1,499 56 48.7/43.9/37.9 48.7/43.9/37.9 150/122/92 -
53/52/50 53/52/50
AZQS100BY1 AZQS125BY1 990x940x320 82 76 77 83 70 71
55/53/50 55/53/50
AZQS140BY1 1,430x940x320 101 83 62 70
48/43 50 -
53/57
54/58
53/54
57
54/58
49 -5~46 -15~15.5 R-410A/1,975
30 40 15.0 -
50 70 30.0 0.5 1~ / 50 / 220-240
20
3N~ / 50 / 380-415 -
(1) EER/COP according to Eurovent 2012, for use outside EU only
9
53/54
AHQ-C / AZQS-BV1/BY1
AHQ125CV1
›› ›› ›› ›› ››
Siesta, ceiling suspended unit
AZQS140BV1/BY1
ARCWLA
Ideal solution for commercial spaces with no or narrow false ceilings Can be installed in both new and existing buildings Air filter removes airborne dust particles to ensure a steady supply of clean air Decrease of temperature variation by automatic fan speed selection or freely selectable 3-step fan speed. Easy installation and maintenance
Heating & Cooling INDOOR UNIT Cooling capacity Heating capacity Power input
Min./Nom./Max. Min./Nom./Max. Cooling Nom. Heating Nom. Seasonal efficiency Cooling Energy label (according to Pdesign EN14825) SEER Annual energy consumption Heating Energy label (Average Pdesign climate) SCOP Annual energy consumption Nominal efficiency EER (cooling at 35°/27° COP nominal load, heating Annual energy consumption at 7°/20° nominal load) Energy label Cooling/Heating Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit Fan - Air flow rate Cooling High/Nom./Low Heating High/Nom./Low Fan - External static pressure High/Nom./Low Sound power level Cooling Heating Sound pressure Cooling High/Nom./Low level Heating High/Nom./Low Piping Liquid OD connections Gas OD Power supply Phase / Frequency / Voltage OUTDOOR UNIT Dimensions Unit Weight Unit Fan - Air flow rate Cooling Heating Sound power level Cooling Sound pressure Cooling level Heating Night quiet mode Operation range Cooling Heating Refrigerant Type/GWP Piping Piping length connections
Power supply Current - 50Hz
kW kW kW kW
AHQ100C -/9.5/-/10.8/3.62 3.17
AHQ125C -/12.1/-/13.5/4.60 3.74
B kW kWh
6.80 4.65 511
kW
6.33
7.60 3.80
kWh
kWh
mm kg m³/min m³/min Pa dBA dBA dBA dBA mm mm Hz / V
mm kg Nom. m³/min Nom. m³/min dBA Nom./Silent operation dBA Nom. dBA Level 1 dBA Ambient Min.~Max. °CDB Ambient Min.~Max. °CWB m m m m Hz / V A
2,332 3.03 3.05 1,120 B/D
2,800 2.62 3.41 1,810 D/B
2.63 3.61 2,300 D/A
260x1,320x634 38 23.8/21.3/18.9 23.8/21.3/18.9
260x1,538x634 45 31.1/27.8/24.8 31.1/27.8/24.8
260x1,786x634 54 34.4/30.6/27.2 34.4/30.6/27.2
59 62 49/48/46 49/48/46
64 64 52/47/46 52/47/46
69 69 52/50/49 52/50/49
AZQS71BV1 770x900x320 67 52.0 48.0 65 48/43 50 -
AHQ140C -/13.0/-/15.5/4.32 4.55
AHQ100C -/9.5/-/10.8/3.62 3.17 B 9.50 4.60 723 A 7.60 3.80 2,800 2.62
-
9.50 4.60 723 A
HeightxWidthxDepth
OU - IU Max. System Equivalent Level difference IU - OU Max. IU - IU Max. Phase / Frequency / Voltage Maximum fuse amps (MFA)
AHQ71C -/6.8/-/7.5/2.24 2.46
AZQS100BV1 AZQS125BV1 990x940x320 81 76 77 83 70 71 53/54/57 58
3.01
AHQ140C -/13.0/-/15.5/4.32 4.55 -
1,810 D/B
2.63 3.61 2,300 D/A
3.01 3.41 2,159 B/B
260x1,538x634 45 31.1/27.8/24.8 31.1/27.8/24.8
260x1,786x634 54 34.4/30.6/27.2 34.4/30.6/27.2
285x1,902x680 70 43.9/39.1/28.3 43.9/39.1/28.3
64 64 52/47/46 52/47/46
69 69 52/50/49 52/50/49
70 70 56/53/46 56/53/46
3.41 2,159 B/B White 285x1,902x680 70 43.9/39.1/28.3 43.9/39.1/28.3 0/0/0 70 70 56/53/46 56/53/46 9.52 15.88 1~ / 50 / 220-240
AHQ125C -/12.1/-/13.5/4.60 3.74
AZQS140BV1 1,430x940x320 102 83 62
54
AZQS100BY1 AZQS125BY1 990x940x320 82 76 77 83 70 71 53/54/57 58 49
-5~46 -15~15.5 R-410A/1,975 30 40 15.0 -
50 70 30.0 0.5 1~ / 50 / 220-240
20
3N~ / 50 / 380-415 -
(1) EER/COP according to Eurovent 2012, for use outside EU only
10
AZQS140BY1 1,430x940x320 101 83 62 70 53/54
ARCWLA / ARCWB
Siesta individual control systems
Overview controllers for Siesta Sky Air SIESTA SKY AIR INDOOR UNITS
CONTROLLERS
ACQ-C 4-way blow, ceiling mounted cassette
- Standard infrared remote control (ARCWLA) in box of decoration panel ADP125A - Optional wired remote control ARCWLB - Optional group controller R04084124324
AHQ-C ceiling suspended
- Standard infrared remote control in box of indoor unit ARCWLA - Optional wired remote control ARCWB - Optional group controller R04084124324
ABQ-C concealed ceiling
- Standard wired remote control (ARCWB) in box of indoor unit - Optional group controller R04084124324
Overview of features FEATURE
ARCWB Option for AHQ-C and ACQ-C Standard for ABQ-C
1
ON/OFF switch
Standard Default range 16-30°C
Standard
Optional range 20-30°C
By dipswitch selection
2
Temperature setting
3
Room temperature sensor on remote control
Switch between °C and °F
Standard Standard
4
Cool / Fan dry / Heat / Auto
Standard
5
Sleep mode
Standard
6
Fan Speed selection
7
Delay timer
Standard 1, 2 & 4 hours delay
8
7-days programmable timer
Standard
9
Real time clock display
Standard
10
Air swing selection
11
LCD display without backlight
Standard
12
Key lock
Standard
13
Error code indication
Standard
14
IR receiver to enable compatibility with infrared remote control (disabled when lock function is activated)
Standard
15
Last state memory from indoor PCB
16
Silent mode
By dipswitch selection
17
Turbo mode
By dipswitch selection
18
Compressor test model (compressor force ON)
Standard
19
Daikin inverter error code
Standard
20
UART communication port (for Daikin protocol)
Standard
21
Backup battery
Standard
ON/OFF swing mode
Standard
Change swing option (draft/soil prevention or standard)
Standard
Standard
Specifications Dimensions (length x width x height) ARCWB: 0.15 m x 0.21 m x 0.04 m. ARCWB comes standard with a 10 meter wire, which can be extended to maximum wire length of 15 meter. ARCWB can only control one indoor unit at a time; group control is only possible when using option R04084124324. 11
Europe’s new energy label: raising the bar on energy efficiency To realise its challenging 20-20-20 environmental goals, Europe is imposing minimum efficiency requirements for energy related projects. These minimum requirements came into effect on 1 January 2013, and will be revised upward in subsequent years. Not only does the Eco-Design Directive systematically raise the minimum requirements with respect to environmental performance, the method used to measure this performance has also been changed to better reflect real-life conditions. The new seasonal performance rating provides a much more accurate picture of actual expected energy efficiency over an entire heating or cooling season. Completing the picture is a new energy label for EU. The present label, introduced in 1992 and modified in the meantime, allows consumers to compare and make purchasing decisions based on uniform labelling criteria. The new label includes multiple classifications from A+++ to D reflected in colour shadings ranging from dark green (most energy efficient) to red (least efficient). Information on the new label includes not only the new seasonal efficiency ratings for heating (SCOP) and cooling (SEER), but also annual energy consumption and sound levels. It will allow end-users to make even better informed choices, since seasonal efficiency reflects air conditioner or heat pump
The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.
Daikin Europe N.V. participates in the Eurovent Certification programme for Liquid Chilling Packages (LCP), Fan coil units (FCU) and Air handling units (AHU). Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com
Daikin products are distributed by:
FSC
ECPEN14-130 Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende
ECPEN14-130 • CD • 05/14 • Copyright Daikin The present publication supersedes ECPEN13-130_SE. Printed on non-chlorinated paper. Prepared by La Movida, Belgium Resp. Ed.: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende
efficiency over an entire season.