4-Cl-PhOK/18-crown-6/PEG300 system. S4. 5. IR spectra of other absorption systems before and after CO2 capture. S5. Electronic Supplementary Material (ESI) ...
Electronic Supplementary Material (ESI) for Green Chemistry This journal is © The Royal Society of Chemistry 2013
Coordination effect-regulated CO2 capture with alkali metal onium salts/crown ether system Zhen-Zhen Yang, De-en Jiang, Xiang Zhu, Chengcheng Tian, Suree Brown, Chi-Linh Do-Thanh, Liang-Nian He* and Sheng Dai*
Table of Contents page 1. General experimental methods
S2
2. Synthesis of alkali metal onium salts
S2
3. Characterization of ProK/18-crown-6/PEG300 and 4-Cl-PhOK/18-crown-6/PEG300 S2 (1H, 13C NMR and FT-IR) before and after CO2 capture 4. Scanning thermogravimetric analysis (TGA) and reusability of the 4-Cl-PhOK/18-crown-6/PEG300 system
S4
5. IR spectra of other absorption systems before and after CO2 capture
S5
S1
Electronic Supplementary Material (ESI) for Green Chemistry This journal is © The Royal Society of Chemistry 2013
1. General experimental methods: Caution Experiments using compressed gase (CO2) are potentially hazardous and must only be carried out by using the appropriate equipment and under rigorous safety precautions. Materials All the reagents used in this work are purchased from Sigma-Aldrich Company and directly used without further purification. CO2 with a purity of 99.99% is commercially available. Experimental methods 1
H and 13C NMR spectra were recorded on a Varian Mercury 300 MHz spectrometer (1H NMR, 300 MHz, 13C NMR, 75 MHz) in CDCl3, the chemical shifts were referenced to the residual solvent. FTIR data were obtained using a Bio-Rad Excalibur FTS-3000 spectrometer. General procedure for absorption and desorption of CO2 In a typical procedure, CO2 capture was carried out in a glass container with an inner diameter of 10 mm. The absorbents were charged into the reactor at room temperature. Then, a needle was used for CO2 bubbling, which was inserted in the bottom of the flask. The absorption reaction was conducted at 25 oC with a CO2 bubbling rate of 80 mL/min. The amount of CO2 absorbed was determined by an analytical balance with an accuracy of ±0.0001 g every five minutes. In a typical desorption of CO2, N2 of atmospheric pressure is bubbled through the absorption system at 50 oC using the same equipment and procedure as CO2 capture. Absorption/desorption is determined by several cycles of repeated experiments.
2. Synthesis of alkali metal onium salts:
The alkali metal onium salts were prepared from the neutralization of various amino acids or phenols with alkali metal hydroxides. For example, in a typical procedure for the synthesis of ProK, equimolar proline was added to an ethanolic solution of KOH. Then, the mixture was stirred at room temperature for 24 h. Subsequently, EtOH was distilled off at 70 oC under vacuum. The obtained solid was washed with ethyl ether three times and dried under vacuum at 80 oC for 24 h.
3. Characterization of ProK/18-crown-6/PEG300 and 4-Cl-PhOK/18-crown-6/PEG300 (1H, 13C NMR and FT-IR) before and after CO2 capture 18-crown-6 1
H NMR (CDCl3, 300 MHz) δ 3.64 (s, 24H);
ProK 1
H NMR (CDCl3, 300 MHz) δ 3.77 (t, 3J = 7.8 Hz, 1H), 3.21-3.29 (m, 1H), 2.96-3.05 (m, 1H), 2.11-2.21 (m, 1H),
1.81-1.99 (m, 3H); ProK/18-crown-6 1
H NMR (CDCl3, 300 MHz) δ 3.61-3.62 (m, 25H), 3.05-3.13 (m, 1H), 2.81-2.89 (m, 1H), 2.03-2.16 (m, 1H),
1.86-1.97 (m, 1H), 1.58-1.72 (m, 2H); ProK/18-crown-6/PEG300
S2
Electronic Supplementary Material (ESI) for Green Chemistry This journal is © The Royal Society of Chemistry 2013
1
H NMR (CDCl3, 300 MHz) δ 3.44-3.58 (m, 78H), 2.94-3.01 (m, 1H), 2.73-2.82 (m, 1H), 1.92-2.04 (m, 1H),
1.79-1.88 (m, 1H), 1.49-1.65 (m, 2H); 13C NMR (CDCl3, 75 MHz) δ 177.7, 77.2, 72.0, 71.9, 69.3-69.7, 61.0, 60.2, 60.1, 46.0, 30.4, 25.1. ProK/18-crown-6/PEG300 + CO2 1
H NMR (CDCl3, 300 MHz) δ 3.98 (s, 1H), 3.56-3.70 (m, 82H), 3.19-3.29 (m, 2H), 2.25 (s, 1H), 1.97-2.09 (m,
1H), 1.70-1.79 (m, 2H); 13C NMR (CDCl3, 75 MHz) δ 175.9, 157.7, 77.2, 72.3, 72.1, 69.5-70.0, 60.8, 60.5, 46.4, 28.9, 24.1. 4-Cl-PhOK 1
H NMR (CDCl3, 300 MHz) δ 7.11 (s, 1H), 7.08 (s, 1H), 6.71 (s, 1H), 6.68 (s, 1H);
4-Cl-PhOK/18-crown-6 1
H NMR (CDCl3, 300 MHz) δ 6.86-6.90 (m, 2H), 6.53-6.57 (m, 2H), 3.60 (s, 84H);
4-Cl-PhOK/18-crwon-6/PEG300 1
H NMR (CDCl3, 300 MHz) δ 6.99 (s, 1H), 6.96 (s, 1H), 6.76 (s, 1H), 6.73 (s, 1H), 3.56-3.70 (m, 140H); 13C
NMR (CDCl3, 75 MHz) δ 165.1, 129.2, 128.0, 119.0, 115.8, 77.2, 72.3, 72.2, 72.18, 69.5, 69.9, 60.4-60.6. 4-Cl-PhOK/18-crown-6/PEG300+CO2 1
H NMR (CDCl3, 300 MHz) δ 6.95-6.99 (m, 2H), 6.73-6.76 (m, 2H), 3.55-3.70 (m, 94H); 13C NMR (CDCl3, 75
MHz) δ 158.7, 157.4, 128.0, 120.3, 117.2, 77.2, 71.9, 69.4-69.8, 60.5. 1
1
O O
4
O
O
O
O K 2 3
O
5
O
Cl
O
O
O
O
4
K O
O
1
O O
5
2 3
O
O 6 O O
4
O
5
K O
Cl
O
3
Cl
1
(a)
18‐crown‐6
3
4‐Cl‐PhOK
2
1 3 3
2 2
4‐Cl‐PhOK/18‐crown‐6 4‐Cl‐PhOK/18‐crown‐6/PEG300 + CO2
S3
2
Electronic Supplementary Material (ESI) for Green Chemistry This journal is © The Royal Society of Chemistry 2013
(b)
3
2
4‐Cl‐PhOK/18‐crown‐6/PEG300 4 4‐Cl‐PhOK/18‐crown‐6/PEG300 + CO2 3 6 4
2 5
4‐ClPhOK/18‐crown‐6/PEG300 4‐ClPhOK/18‐crown‐6/PEG300+CO2 0.2
(c) 0.8
1647 cm‐1
Absorbance
0.7
0.15
0.6
0.1
0.5
0.05
0.4
0 1500
0.3
1600
1700
1800
0.2 0.1 0 600
1600 2600 Wave number/cm‐1
3600
1
Figure S1. (a) H NMR spectra (CDCl3, 300 MHz) of 18-crown-6, 4-Cl-PhOK, 4-Cl-PhOK/18-crown-6 and 4-Cl-PhOK 13 /18-crown-6/PEG300+CO2 (from top to bottom); (b) C NMR spectra (CDCl3, 75 MHz) of 4-Cl-PhOK /18-crown-6/PEG300 before (top) and after (bottom) CO2 absorption. (c) FT-IR spectrum of 4-Cl-PhOK /18-crown-6/PEG300 before (black line) and after (blue line) CO2 absorption.
4. Scanning thermogravimetric analysis (TGA) and reusability of the 4-Cl-PhOK/18-crown-6/PEG300 system
S4
Electronic Supplementary Material (ESI) for Green Chemistry This journal is © The Royal Society of Chemistry 2013
4‐Cl‐PhOK/18‐crown‐ 6/PEG300+CO2 18‐crown‐6
Weight/%
(a) 100 90 80 70 60 50 40 30 20 10 0
PEG300
0
(b)
100
200 300 Temperature/oC
400
500
1
0.9
CO2 capacity
0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0
50
100 Time/min
150
200
Figure S2. (a) Scanning thermogravimetric analysis (TGA) results for 4-Cl-PhOK /18-crown-6/PEG300+CO2 with a 10 -1 o o C min temperature ramping rate to 500 C. (b) Six consecutive cycles of CO2 absorption (♦ 15 min, 25 C, CO2) and o release (◊ 20 min, 80 C, N2) by 4-Cl-PhOK/18-crown-6/PEG300 system, data were obtained every 5 min. o
5. IR spectra of other absorption systems before and after CO2 capture
S5
Electronic Supplementary Material (ESI) for Green Chemistry This journal is © The Royal Society of Chemistry 2013
0.8
PhOK/18‐crown‐6/PEG300 PhOK/18‐crown‐6/PEG300+CO2
0.7
0.2
0.6
1649 cm‐1
Absorbance
0.15
0.5
0.1
0.4
0.05
0.3
0 1500
0.2
1550
1600
1650
0.1 0 600
1600 2600 Wave number/cm‐1
3600
0.6
PhONa/15‐crown‐5/PEG300
0.5
PhONa/15‐crown‐5/PEG300+CO2 0.2 1641 cm‐1 0.15
Absorbance
0.4
0.1 0.05
0.3
0 1500 1600 1700 1800
0.2 0.1 0 700
1700 2700 Wave number/cm‐1
S6
3700
1700
Electronic Supplementary Material (ESI) for Green Chemistry This journal is © The Royal Society of Chemistry 2013
0.6
PhOLi/12‐crown‐4/PEG300 PhOLi/12‐crown‐4/PEG300+CO2 0.2
0.5
1603 cm‐1
Absorbance
0.15 0.4 0.1 0.05
0.3
0 1500 1550 1600 1650 1700
0.2 0.1 0 600
1600 2600 Wave number/cm‐1
3600
ProNa/15‐crown‐5/PEG300 0.6
ProNa/15‐crown‐5/PEG300+CO2 0.2 ‐1
1589 cm
Absorbance
0.5
1622 cm‐1
0.15 0.1
0.4
0.05 0.3
0 1500
0.2
1600
1700
0.1 0 600
1600 2600 Wave number/cm‐1
S7
3600
1800
Electronic Supplementary Material (ESI) for Green Chemistry This journal is © The Royal Society of Chemistry 2013
0.9
ValK/18‐crown‐6/PEG300 ValK/18‐crown‐6/PEG300+CO2
0.8
Absorbance
0.7 0.6 0.5 0.4 0.3
1659 cm‐1
0.2 0.1 0 600
1100
1600 2100 2600 3100 Wave number/cm‐1
0.8
3600
MetK/18‐crown‐6/PEG300
0.7
MetK/18‐crown‐6/PEG300+CO2
Absorbance
0.6 0.5 0.4 0.3 0.2
1661 cm‐1
0.1 0 600
1100
1600
2100
2600
3100
3600
Wave number/cm‐1 0.9
GlyK/18‐crown‐6/PEG300 GlyK/18‐crown‐6/PEG300+CO2
0.8 0.7
Absorbance
0.6 0.5 0.4 0.3
1658 cm‐1
0.2 0.1 0 600
1100
1600 2100 2600 Wave number/cm‐1
S8
3100
3600
Electronic Supplementary Material (ESI) for Green Chemistry This journal is © The Royal Society of Chemistry 2013
0.8
ThrK/18‐crown‐6/PEG300
0.7
ThrK/18‐crown‐6/PEG300+CO2
Absorbance
0.6 0.5 0.4 0.3
1659 cm‐1
0.2 0.1 0 600
1100
1600 2100 2600 Wave number/cm‐1
0.9
3600
AlaK/18‐crown‐6/PEG300 AlaK/18‐crown‐6/PEG300+CO2
0.8
1597 cm‐1 1620 cm‐1
0.7
Absorbance
3100
0.2
0.6 0.1
0.5 0.4
0 1500 1600 1700 1800
0.3 0.2 0.1 0 600
1600 2600 Wave number/cm‐1
3600
0.8
LeuK/18‐crown‐6/PEG300
0.7
LeuK/18‐crown‐6/PEG300+CO2
Absorbance
0.6 0.5 0.4 0.3
1661 cm‐1
0.2 0.1 0 600
1100
1600
2100
2600
Wave number/cm‐1 S9
3100
3600
Electronic Supplementary Material (ESI) for Green Chemistry This journal is © The Royal Society of Chemistry 2013
0.8
SerK/18‐crown‐6/PEG300
0.7
SerK/18‐crown‐6/PEG300+CO2
Absorbance
0.6 0.5 0.4 0.3 0.2
1661 cm‐1
0.1 0 600
1100
1600 2100 2600 3100 Wave number/cm‐1
S10
3600