Significantly greater efficiency is realized by the use of DC Inverter. Hermetic
Scroll .... With this Variable Refrigerant Flow (VRF) technol- ogy, we can quickly
get ...
DC Inverter VRF Air Conditioning Systems
CATALOGUE 2011
YOUR CONDITIONS!
index INV
Since 1916,
pioneers in the US market, by designing and manufacturing innovative air conditioning and
heat pump units. The company’s primary competitive advantage is the use of its know-how expertise gained in the past, to build air conditioning systems of the future. The key to
units' success is that they are specifically designed to enable the modern individual invent his
own custom made living and working conditions. Regulating effectively the natural environment, units can create silently the perfect indoor conditions; your conditions!
All units carry a 2-year Warranty for the compressor and for all parts of the unit.
units can be found all across Europe in a continuously growing selected network of air conditioning profes-
Features
Pages
Higher Efficiency Better Comfort Higher Reliability Better Versatility Easy Installation & Maintenance INV Mini
4-5 6-7 8-9 10-11 12-13 14-15
Outdoor Units
Pages
Line up Specifications
16-17 18-21
Indoor Units
Pages
Line up Duct Type Slim Duct Type Four-way Cassette Type One-way Cassette Type Floor Standing Type Wall Mounted Type Floor Ceiling Type Treated Fresh Air Duct Type
22-23 24-27 28-29 30-33 34 35 36-37 38-41 42-43
Control System
Pages
Control Network Sketch Controllers Comparison Comments of Control Functions Wired Remote Controller Wireless Remote Controller Group Controller Smart Zone Controller Centralized Controller IR Receiver & Key-card Control Board Communication Module Commissioning Program RS-422/485 Repeater RS-232 to RS-422/485 Converter INVENTOR Eudemon 2009 PC SUIT Piping Design Program
44-45 46 47 48-49 50-51 52 53 54 55 56 57 58 59 60-61 62-63
Energy Recovery Ventilation Connection Branches
64-66 67
sionals! Their excellent quality and operational efficiency has been awarded by the European Union with the highest standard certificates. Furthermore, the use of the environmental friendly refrigerants (freon) do not contribute to the increase of the global warming environment.
ISO 9001 ISO 14001
) DC Fan motor Compared with the former model, airflow volume is increased 3% with the same single fan and 7% with the new dual fan, but the power consumption is decreased by 5% with the DC inverter motor. › 8HP/10HP Models
Air flow volume
HIGHER EFFICIENCY ) Significantly improved EER/COP Significantly greater efficiency is realized by the use of DC Inverter Hermetic Scroll Compressors with high-pressure chamber design, improved DC inverter driving technology and large heat exchanger.
27%
INV
Former model
Former model
› 12HP/14HP Models
Air flow volume
increase of COP 4.37
4.07 4.0
4.0
3.5
3.5
3.7
Former model
INV
2.5
INV
Former model
✍ • EER is the efficiency rate= cooling capacity (kW) ÷ cooling power input (kW) COP is the coefficient of performance = heating capacity (kW) ÷ heating power input.
Compressor
› T he bigger condenser increases the heat-exchange area, improving the efficiency.
›C ompared with the normal fin, the heat exchange efficiency of the louver is increased by 5%.
›S pecial thickened inner groove copper tube enhances heat exchanging performance.
INV
Heat Exchanger Fan Motor
INV
) Heat Exchanger
3.0
Former model
7% Former model
3.2
2.5
INV
18%
increase of EER
3.0
3%
• E ER/COP values are based on INVENTOR laboratory testing method The data refers to a 8HP outdoor unit
Former model: 2098x38.1x1156
INV:
2248x38.1x1190
Former model: Normal flat fin
INV:
Louver fin with golden coated
) High efficiency compressor High pressure chamber design What’s high pressure chamber? The compressed gas that is discharged from the fix scroll, fulfills the whole hermetic chamber of the compressor. Then, when the whole compressor shell has high temperature and there is high pressure inside the compressor, the gas goes out from the exhaust. What’s the Benefit of High Pressure Chamber? Direct suction in high pressure chamber compressor. No loss from overheat suction. Increased compressor efficiency up to 3-5%.
›C omparing with normal compressor, the DC Inverter Scroll compressor can save up to 40% of energy consumption in a year.
›W ith stepless power regulating technology, the DC inverter compressor achieves stepless output regulation between 20Hz-120Hz
› Improved DC inverter motor Low frequency performance is highly raised thanks to the concentrated winding.
Suction
Fixed Scroll
Orbiting Scroll
Discharge
Low Pressure Intermediate Pressure Chamber Motor in high Pressure
Distributed winding
Intermediate Pressure HP chamber structure can raise the high and middle frequency performance New DC motor (concentrated winding) raises the low frequency performance
Compressor efficiency
High Pressure
Concentrated winding
7% 0
20
Rotating speed (/rps)
) Comfortable
58dB(A)
Capacity Operating sound
50dB(A)
Capacity Operating sound
Heat load
Less Cool
Uncomfortable Comfortable
Cooler
Uncomfortable
› Intelligent defrost technology Traditional defrost program • Simply executes defrosting according to a certain time. • The defrost function may still start even if there is no such (defrosting) demand.
› Low noise design OUTDOOR UNIT • HP chamber compressor has lower exhaust pressure fluctuation, so the noise is lower.
• The optimized design of the condensing fan blade reduces the air flow turbulence among blades. So, the noise is lower.
Quiet compressor
Average 2dB(A) down
Optimized
Original design
INDOOR UNIT
New design with higher performance &lower noise 4dB(A) less!
› Low noise indoor unit
the room
Intelligent defrost program •Humanized technology which considers the maximization of energy saving. • Defrosting program that is designed under the consideration of heating efficiency and operation reliability. •Precise defrosting timing, which is intelligent indeed. • It’s an optimized defrosting program, which will be performed only when the system’s pressure is too low. This can obviously lengthen the time gap between two defrost operations and reduce the times of defrosting. • Heating capacity loss has been decreased by 75% with highly comfortable heating operation.
INV
Non VRF
Defrosting
Heating
Defrosting
Heat Loss
› Quiet operation during night time The Intelligent adjustment of the outdoor fan control can minimize the operation noise during night time. It can be reduced up to 8dB(A). So the operating noise at night is lower, at 50dB(A).
fluctuation of
Heating Capacity
) Quiet Operation
Temperature
Time 10mins
50mins
10mins
50mins
10mins
Defrosting
Heating Capacity
BETTER COMFORT
› Precise temperature control The EXV (Electronic Expansion Valve) of each Indoor unit responds to the loading changes of indoor environment, so it continually adjusts the flow rate of refrigerant. Meanwhile, the outdoor unit with DC inverter compressor provides the capacity with certain amount of refrigerant exactly according to the total demands of the indoor units. With this Variable Refrigerant Flow (VRF) technology, we can quickly get a nearly constant room temperature. The typical temperature fluctuation that occurs with a conventional ON/OFF control system is eliminated.
Heating
Time Defrosting starts if the unit detects frost
Defrosting stops after completion
› Individual control The set temperature of each room may vary by the individual thermostat control of each indoor unit.
OFF 37dB(A) Office Duct Type with High ESP
37dB(A) Reception Four-way Cassete Type
26 C 0
220C 37dB(A) Hotel Slim Duct Type
200C 240C
270C
28dB(A) Bedroom Wall Mounted Type
HIGHER RELIABILITY ) Modular operating › T he operating priority sequence of the outdoor unit modules will be changed without restart when the system accumulatively operates for 12 hours. This can maximize the service life of the system.
12hours Rotation
) PCB protection design
) Anti-corrosion
With unique high efficiency radiating air-dust design, the outdoor electric box is designed as water-proof, dust-proof, damp-proof and well –ventilated. This can ensure the required condition for the electric elements even in tropical conditions. Also, it improves the system’s reliability and service life.
The primary material of Golden Fin is Al-Mn (Aluminum-Manganese) anti-rust alloy, which is coated with the Golden Protection Layer (Components: Epoxy Resin & Modified Acrylic, Silicon free). The anti-corrosive performance in salt-spray testing is 200%-300% higher than normal Blue Fin*. Hydrophilic Layer Golden Protection Layer (Epoxy resin & Modified Acrylic)
Al-Mn-corrosive alloy
› Emergency operation Each module is an independent sub-system. The whole system won’t fail down even if partial malfunction occurs. If a malfunction occurs at any module, there can be performed an emergency operation. This can simply be achieved by setting up manually the outdoor PCB switches.
*Salt-spary testing result is from INVENTOR materials chemistry testing laboratory
Air outlet
) New generation of oil return control The pressure control achieves an optimized oil return of the system. As a result, the operating life of the compressor is greatly improved.
12hours Rotation
Negative pressure
Electric Box Baffle
Operating
Electric Box Cover
Backflow
Guide louver Malfunction 12hours Rotation
Positive pressure Air inlet Front pane
Emergency Operation
12hours Rotation
) High efficiency oil-balanced technology ) Continuous operation of indoor units Each indoor unit is controlled individually on the system network. This allows all indoor units to continue operating even if an error occurs at any indoor unit on the VRF system.
High-pressure chamber Suction pipe compressor with oil-balanced pipe can automatically drain out the excess oil. Discharge pipe This can prevent an oil-unbalance between the compressors. Auto-oil pipe
› New patented oil separator allows the oil separating efficiency up to 99%. ›O il equalizing pipe connection designed at the outside of the module allows high reliability. Before Oil Balanced
After Oil Balanced
Failure
) Wide voltage range operation
) Power supply security
The unit can safely operate within 342V-456V
With power supply security, the outdoor unit will start autoprotection if the power voltage or the current is out of the normal range. Protection will be relived automatically if the power condition resumes normal.
342V
456V Safe operation range
Compressors Oil storage tank
Oil equalizing pipe
Oil equalizing pipe
)C ompact Design Compact size has been achieved by significantly reducing the width of the outdoor units compared to previous models. Former model (8HP)
The maximum external static pressure (ESP) of the outdoor fan can reach up to 75Pa*. The outdoor unit can be installed in the equipments room of high buildings.
880mm
Floor area: 0,87m
* Default ESP of the product is 40Pa. If higher ESP is required, please contact us.
* T his value is based on the case that the outdoor unit is located above the indoor unit. If the outdoor unit is located underneath the indoor unit, the value is 40m.
50m
150m
INV (16HP)
41% reduction
(990+990)mm Floor area: 1,74m
930mm
Floor area: 0,72m2
2
Former model (8HP + 8HP)
880mm
1670mm 770mm
990mm
1670mm
›M aximum total piping length --- 500m ›M aximum actual piping length --- 150m ›M aximum equivalent piping length --- 175m ›M aximum height difference between indoor units --- 15m ›M aximum height difference between outdoor and indoor units --- 50m* ›M aximum piping length from first indoor branch to the farthest indoor unit --- 40m
)H igher Static pressure of outdoor unit
reduction
1772mm
) Long piping design
17%
1772mm
BETTER VERSATILITY
INV (8HP)
2
770mm
1340mm
Floor area: 1,03m2
)M odular outdoor unit design
15m
40m
›V arious combinations from 8HP to 64HP with 2HP increments. ›M ax capacity of outdoor unit is 180kW (4 x modules)
)V arious combinations
) Wide operation range The unit can operates in wide range, greatly reducing the ambient temperature limitation.
✍ • If the required capacity of indoor units is 50% higher than the outdoor unit, the cooling range may be lower up to –150C • If the required capacity of indoor units is 50% lower than the outdoor unit, the cooling range may be up to –50C.
10
Heating
›U p to 110 sets of indoor units can be connected*
Cooling
*For the standard model that 4 models connect in parallel, up to 64 indoor units can be connected. If more indoor units are required to be connected please contact us.
› 12 types and 69 models. › Maximum diversity is 135%
11
)E asier transportation & installations ›L ight weight Former model (8HP+8HP): 240x2=480kg
INV (16HP): 370kg
›O ptimized base frame Optimized base frame. The locating and fixing of the outdoor unit during installation is more convenient and reliable.
EASY INSTALATION & MAINTENANCE ) Easier maintainability ›S pecial-designed elecric box. The electric box can be opened by inverting downwards, for easy maintenance.
›T ransportation by forklift
›F ive-Way piping connection • Piping and wiring are available to the front and back, left and right, bottom. • The five-way piping connection reduces installation difficulty and cost. Improves the installation efficiently.
› Compact design With compact design, the outdoor unit can be carried to the roof of a building through elevator. No crane is needed. ›E rror display & Self-diagnostics system. Any malfunction can be judged by the LED display that is on the main board (different combinations of ON/OFF or BLINK).
Traditional Central Air Conditioner INV
• Self diagnostics system display
12
• LED display on the connection board
• LED display on the connection board
13
INV MINI ) High efficiency
) Comfort
›L ong piping design • Maximum total piping length --- 150m • Maximum actual piping length --- 70m • Maximum equivalent piping length --- 80m • Maximum height difference between indoor units --- 10m • Maximum height difference between outdoor and indoor units --- 30m* • Maximum piping length from first indoor branch and the farthest indoor unit --- 25m
DC inverter rotary compressor
Auto quiet operation The unit is ensured to operate with the lowest noise due to the ultra-low fan speed and auto adjustment according to system parameters. The operation noise of the unit is reduced by 3dB(A) at lower loading.
70m
30m
) Flexible Design
Operation noise
3dB(A)
25m
10m
* This value is based on the outdoor unit to be located above the indoor unit. If the outdoor unit is located underneath the indoor unit, the value is 25m.
) Easy Installation When total piping length is less than 50m [(A+B+C+D+a+b+c+d) ≤ 50m], no additional refrigerant is required.
➢› C ompact Design Compact size has been achieved by significantly reducing the width of the outdoor units compared to previous models.
1100mm Floor area: 0,374m
INV
) Powerful heating in low temperature
14%
1250mm
1250mm
Former Model
reduction
340mm
340mm
When outdoor ambient temperature is low, the system can automatically increase the heating effect according to its judgment on parameters. Heating performance is improved by 15%, which brings great comfort.
950mm
Floor area: 0,323m2
2
) Capacity MODEL
)W ide voltage range operation The unit can safely operate within the power supply voltage of 185V to 264V.
14
185V
264V
Capacity Power Supply
HP kW
INV-Pd100W/NaB-K
INV-Pd120W/NaB-K
INV-Pd140W/NaB-K
INV-Pd160W/NaB-K
3.5 10
4.0 12
5.0 14
6.0 16
1Phase, 220-240V, 50Hz
Safe operation range
15
INV-Pdm224W/ NaB-M (8HP)
MODEL
INV-Pdm280W/ NaB-M (10HP)
INV-Pdm335W/ NaB-M (12HP)
INV-Pdm400W/ NaB-M (14HP)
INV-Pdm450W/ NaB-M (16HP)
INV-Pdm950W3/ NaB-M (34HP)
OUTDOOR UNITS LINEUP INV-Pdm224W/ NaB-M (8HP)
MODEL
16
INV-Pdm280W/ NaB-M (10HP)
INV-Pdm335W/ NaB-M (12HP)
INV-Pdm1008W3/ NaB-M (36HP)
INV-Pdm400W/ NaB-M (14HP)
INV-Pdm450W/ NaB-M (16HP)
INV-Pdm1605W3/ NaB-M (38HP)
INV-Pdm224W/ NaB-M (8HP)
INV-Pdm1130W3/ NaB-M (40HP)
INV-Pdm228W/ NaB-M (10HP)
INV-Pdm1180W3/ NaB-M (42HP)
INV-Pdm335W/ NaB-M (12HP)
INV-Pdm11253W3/NaBM (44HP)
INV-Pdm400W/ NaB-M (14HP)
INV-Pdm1300W3/ NaB-M (46HP)
INV-Pdm450W/ NaB-M (16HP)
INV-Pdm11350W3/NaBM (48HP)
INV-Pdm504W2/ NaB-M (18HP)
INV-Pdm1405W4/ NaB-M (50HP)
INV-Pdm560W2/ NaB-M (20HP)
INV-Pdm1456W4/ NaB-M (52HP)
INV-Pdm615W2/ NaB-M (22HP)
INV-Pdm1512W4/ NaB-M (54HP)
INV-Pdm670W2/ NaB-M (24HP)
INV-Pdm1570W4/ NaB-M (56HP)
INV-Pdm730W2/ NaB-M (26HP)
INV-Pdm1650W4/ NaB-M (58HP)
INV-Pdm785W2/ NaB-M (28HP)
INV-Pdm1700W4/ NaB-M (60HP)
INV-Pdm850W2/ NaB-M (30HP)
INV-Pdm1750W4/ NaB-M (62HP)
INV-Pdm900W2/ NaB-M (32HP)
INV-Pdm1800W4/ NaB-M (64HP)
17
SPECIFICATIONS INV Mini RATING CAPACITY
HP
MODEL Combination units Connectable indoor unit Power supply
Maximum Cooling Capacity (kW)
Cooling (kW) Heating (kW) Cooling (kW) Power consumption Heating (kW) Compressor Type m3/h Airflow rate CFm Sound pressure level (dB(A)) Dimensions WxDxH (mm) Net weight Refrigerant charge
kg
5
6
INV-Pd 100W/NaB-K
INV-Pd 120W/NaB-K
INV-Pd 140W/NaB-K
INV-Pd 160W/NaB-K
6 5.0-13.5
7 8 6.0-16.2 7.0-18.9 1-Phase, 220-240V, 50Hz 12.0 14.0 14.0 15.4 3.50 4.36 3.40 4.05 DC inverter dual-rotor type compressor x 1 6200 6000 3642 3525 58 58 950x340x1250 950x340x1250 135 135 7.5 7.5 Cooling: 10 to 48, Heating: -15 to 27 Cooling: 18 to 118.4, Heating: -4 to 81 5/8 5/8 3/8 3/8
6200 3642 58 950x340x1250 135 7.5
°C °F
Operation range Connection pipe diameter
4
10.0 11.0 2.86 2.60
Capacity
Gas Liquid
inch
Combination Modules
3.5
5/8 3/8
RATING CAPACITY
9 8.0-21.6 16.0 17.6 4.98 4.85 6400 3759 58 950x340x1250 135 7.5
3/4 3/8
HP
MODEL
Combination units Connectable indoor unit Power supply Capacity Power consumption Compressor Airflow rate
Maximum Cooling Capacity (kW) Cooling (kW) Heating (kW) Cooling (kW) Heating (kW) Configration* m³/h CFm
Sound pressure level (dB(A)) Dimensions WxDxH Net weight Refrigerant charge
Gas Liquid
RATING CAPACITY
RATING CAPACITY
HP
MODEL Maximum Cooling Capacity (kW)
Cooling (kW) Heating (kW) Cooling (kW) Power consumption Heating (kW) Compressor Configration* m3/h Airflow rate CFm Sound pressure level (dB(A)) Dimensions WxDxH Net weight Operating range Refrigerant charge Capacity
Connection pipe diameter
Gas Liquid
*DC: DC inverter scroll compressor
18
mm kg °C °F
Operation range
Inch HP
MODEL
Basic Module Combination units Connectable indoor unit Power supply
kg °C °F
Operation range Connection pipe diameter
mm
inch
8 INV-Pdm 224W/ NaB-M
10 INV-Pdm 280W/ NaB-M
12 INV-Pdm 335W/ NaB-M
16 16 14.0 - 37.8 16.8 - 45.2 3-Phase, 380-415V, 50Hz 22.4 28.0 33.5 25.0 31.5 37.5 5.52 7.52 9.23 5.82 7.70 9.38 DCx1+Cx1 10000 10000 13000 5874 5874 7636 58 58 60 930x770x1670 255 256 350 275 275 380 12 13 15 Cooling: -5 to 48, Heating: -20 to 27 Cooling: 23 to 118.4, Heating: -4 to 81 7/8 7/8 9/8 3/8 3/8 1/2
14 11.2 - 30.2
C: Constant speed scroll compressor
14 INV-Pdm 400W/ NaB-M
16 INV-Pdm 450W/ NaB-M
16 20.0 - 54.0
16 22.5 - 60.8 45.0 50.0 14.32 13.90
40.0 45.0 12.45 11.2 DCx1+Cx2 13000 7636 61 1340x770x1670 350 380 16
9/8 1/2
13000 7636 61 370 400 17 9/8 1/2
Combination units
Connectable indoor unit Power supply Capacity Power consumption Compressor Airflow rate
Maximum Cooling Capacity (kW) Cooling (kW) Heating (kW) Cooling (kW) Heating (kW) Configration* m³/h CFm
Sound pressure level (dB(A)) Dimensions WxDxH Net weight Refrigerant charge
kg °C °F
Operation range Connection pipe diameter
mm
Gas Liquid
*DC: DC inverter scroll compressor
Inch
18 INV-Pdm 504W2/ NaB-M
20 INV-Pdm 560W2/ NaB-M
22 INV-Pdm 615W2/ NaB-M
24 INV-Pdm 670W2/ NaB-M
26 INV-Pdm 730W2/ NaB-M
INV-Pdm 224W/ NaB-M INV-Pdm 280W/ NaB-M
INV-Pdm 280W/ NaB-M INV-Pdm 280W/ NaB-M
INV-Pdm 280W/ NaB-M INV-Pdm 335W/ NaB-M
INV-Pdm 280W/ NaB-M INV-Pdm 400W/ NaB-M
INV-Pdm 280W/ NaB-M INV-Pdm 450W/ NaB-M
30 25.2-68
32 32 32 32 28.0-75.6 30.8-83.0 33.5-90.5 36.5-98.6 3-Phase, 380-415V, 50Hz 50.4 56.0 61.5 68.0 73.0 56.5 63.0 69.0 76.5 81.5 13.04 15.04 16.75 19.97 21.84 13.52 15.40 17.08 18.90 21.60 (DCx1+Cx1)x2 (DCx1+Cx1)+(DCx1+Cx2) 10000x2 10000+13000 5874x2 5874+7636 62 62 62 62 63 (930x770x1670)+(930x770x1670) (930x770x1670)+(1340x770x1670) 255+255 255+255 255+350 255+350 255+370 13+13 13+15 13+15 13+16 13+17 Cooling: -5 to 48, Heating: -20 to 27 Cooling: 23 to 118.4, Heating: -4 to 81 9/8 9/8 9/8 9/8 11/8 5/8 5/8 5/8 3/4 3/4
28 INV-Pdm 785W2/ NaB-M
30 INV-Pdm 850W2/ NaB-M
32 INV-Pdm 900W2/ NaB-M
34 INV-Pdm 950W3/ NaB-M
36 INV-Pdm 1008W3/ NaB-M
INV-Pdm 335W/ NaB-M INV-Pdm 450W/ NaB-M
INV-Pdm 400W/ NaB-M INV-Pdm 450W/ NaB-M
INV-Pdm 450W/ NaB-M INV-Pdm 450W/ NaB-M
INV-Pdm 280W/ NaB-M INV-Pdm 280W/ NaB-M INV-Pdm 400W/ NaB-M
INV-Pdm 1008W/ NaB-M INV-Pdm 280W/ NaB-M INV-Pdm 450W/ NaB-M
32 39.3-106.0
32 32 48 48 42.5-114.8 45.0-121.5 47.5-128.3 50.4-136.1 3-Phase, 380-415V, 50Hz 78.5 85.0 90.0 96.0 101.0 87.5 95.0 100.0 108.0 113.0 23.55 26.77 28.64 27.49 29.36 23.28 25.10 27.8 26.60 29.30 (DCx1+Cx2)x2 [(DCx1+Cx1)x2]+(DCx1+Cx2) 13000x2 10000x2+13000 7636x2 5874x2+7636 63 63 63 64 64 (1340X770X1670)+(1340X770X1670) (930x770x1670)+(930x770x1670)+(1340x770x1670) 350+370 350+370 370+370 255+255+350 255+255+370 15+16 18+17 17+17 13+13+16 13+13+17 Cooling: -5 to 48, Heating: -20 to 27 Cooling: 23 to 118.4, Heating: -4 to 81 11/8 11/8 11/8 11/8 11/8 3/4 3/4 3/4 3/4 3/4
C: Constant speed scroll compressor
19
Combination Modules RATING CAPACITY
HP
MODEL
Combination units
Connectable indoor unit Power supply
Maximum Cooling Capacity (kW)
Cooling (kW) Capacity Heating (kW) Cooling (kW) Power consumption Heating (kW) Compressor Configration* m³/h Airflow rate CFm Sound pressure level (dB(A)) Dimensions WxDxH Net weight Refrigerant charge
kg °C °F
Operation range Connection pipe diameter
mm
Gas Liquid
RATING CAPACITY
Inch
HP
MODEL
Combination units
Connectable indoor unit Power supply
Maximum Cooling Capacity (kW)
Cooling (kW) Heating (kW) Cooling (kW) Power consumption Heating (kW) Compressor Configration* m³/h Airflow rate CFm Sound pressure level (dB(A)) Capacity
Dimensions
WxDxH
Net weight Refrigerant charge
kg
Operation range
°C °F
Connection pipe diameter
Gas Liquid
*DC: DC inverter scroll compressor
20
mm
Inch
38
40
42
44
46
48
INV-Pdm 1065W3/NaB-M
INV-Pdm 1130W3/NaB-M
INV-Pdm 1180W3/NaB-M
INV-Pdm 1235W3/NaB-M
INV-Pdm 1300W3/NaB-M
INV-Pdm 1350W3/NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm335W/ NaB-M
INV-Pdm400W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm335W/ NaB-M
INV-Pdm400W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
48 53.3-143.8
48 48 48 48 48 56.5-152.6 59.0-159.3 61.81-166.7 65.0-175.5 67.5-182.3 3-Phase, 380-415V, 50Hz 106.5 113.0 118.0 123.5 130.0 135.0 119.0 126.5 131.5 137.5 145.0 150.0 31.07 34.29 36.16 37.87 41.09 42.96 30.98 32.80 35.50 37.18 39.00 41.70 (DCx1+Cx1)+[(DCX1+Cx2)x2] (DCx1+Cx2)x3 10000+13000x2 13000X3 5874+7636x2 7636x3 64 64 64 65 65 65 (930x770x1670)+(1340x770x1670)+(1340x770x1670) (1340x770x1670)+(1340x770x1670)+(1340x770x1670) 255+350+370 350+370+370 350+370+370 370+370+370 13+15+17 13+16+17 13+17+17 15+17+17 16+17+17 17+17+17 Cooling: -5 to 48, Heating: -20 to 27 Cooling: 23 to 118.4, Heating: -4 to 81 1” 5/8 1” 5/8 1” 5/8 1” 5/8 1” 5/8 1” 5/8 3/4 3/4 3/4 3/4 3/4 3/4
50 INV-Pdm1405W4/ NaB-M
52 INV-Pdm1456W4/ NaB-M
54 INV-Pdm1512W4/ NaB-M
56 INV-Pdm1570W4/ NaB-M
58 INV-Pdm1650W4/ NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm280W/ NaB-M
INV-Pdm335W/ NaB-M
INV-Pdm400W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm400W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm400W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
64 78.5-212.0
64 82.5-222.8 163.0 181.5 50.48 49.90
64 70.3-189.7
64 64 72.8-196.6 75.6-204.1 3-Phase, 380-415V, 50Hz 141.0 146.0 151.5 158.0 163.0 169.0 41.84 43.68 45.39 40.05 43.20 44.88 [(DCx1+Cx1) x2]+[(DCx1+Cx2)x2] 10.000x2+13.000x2 5.874x2+7.636x2 65 65 65
(930x770x1.670)+(930x770x1.670)+ +(1.340X770X1670)+(1.340X770X1.670) 255+255+350+370 13+13+16+17
1” 3/4 7/8
155.0 176.5 48.61 46.70 (DCx1+Cx1)+[(DCx1+Cx2) x3] 10.000+13.000x3 5.874+7.636x3 65
Combination Modules RATING CAPACITY MODEL
HP
Combination units
Connectable indoor unit Power supply
Maximum Cooling Capacity (kW)
Cooling (kW) Heating (kW) Cooling (kW) Power consumption Heating (kW) Compressor Configration* m³/h Airflow rate CFm Sound pressure level (dB(A)) Dimensions WxDxH Net weight Refrigerant charge
Capacity
kg °C °F
Operation range Connection pipe diameter
mm
Gas Liquid
*DC: DC inverter scroll compressor
Inch
60 INV-Pdm1700W4/NaB-M
62 INV-Pdm1750W4/NaB-M
64 INV-Pdm1800W4/NaB-M
INV-Pdm335W/ NaB-M
INV-Pdm400W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
INV-Pdm450W/ NaB-M
64 85.0-230.0
64 64 87.5-236.3 80.0-243.0 3-Phase, 380-415V, 50Hz 168.0 175.0 180.0 187.5 195.0 200.0 52.19 55.41 57.21 51.80 52.90 55.60 (DCx1+Cx2) x4 13000x4 7636x4 66 66 66 (1340x770x1670)+(1340x770x1670)+(1340x770x1670)+(1340x770x1670) 350+370+370+370 15+17+17+17 16+17+17+17 17+17+17+17 Cooling: -5 to 48, Heating: -20 to 27 Cooling: 23 to 118.4, Heating: -4 to 81 2” 1/8 2” 1/8 2” 1/8 1 1 1 C: Constant speed scroll compressor
65
(930x770x1.670)+(1.340x770x1.670)+ +(1.340x770x1670)+(1.340x770x1.670)
255+255+350+370 255+350+370+370 255+350+370+370 13+13+17+17 13+15+17+17 13+16+17+17 Cooling: -5 to 48, Heating: -20 to 27 Cooling: 23 to 118.4, Heating: -4 to 81 1” 3/4 7/4 2” 1/8 7/8 7/8 1
255+370+370+370 13+17+17+17
2” 1/8 1
C: Constant speed scroll compressor
21
INDOOR UNITS LINEUP CAPACITY INDEX (kW)
2.2
2.8
3.6
4.5
5.0
5.6
6.3
7.1
8.0
9.0
10.0
11.2
12.5
14.0
22.4
28.0
Duct Type (EXV Integrated)
Slim Duct Type (EXV Integrated) Four-way Cassette Type (EXV Integrated) Compact Four-way Cassette Type (EXV Separated) One-way Cassette Type (EXV Separated) Floor Standing Type Floor Ceiling Type (EXV Separated) Floor Ceiling Type (EXV Integrated)
Wall Mounted Type (EXV Separated)
Wall Mounted Type (EXV Integrated) Treated Fresh Air Duct Type 22
23
) Drain pump lift reaches 1000mm Only available for INV(L)-R*PS/NaB-K
) Easy maintenance
DUCT TYPE
› Long life and washable filter with buckles can be easily disassembled from each direction. › Compact size has been achieved by significantly reducing the width of the outdoor units compared to previous models.
) Highly flexible installation › Highly flexible installation is possible to satisfy various needs Installation examples
Return air inlet Indoor unit Supply air duct
Former structure: push pull type The former structure is not easy to disassembly.
Canvas air duct Indoor unit Long life filter
Long life filter
) HIGHER ESP & lower noise
Maintenance access
The ESP is obviously upgraded while the noise is almost at the same level as before.
Former model High ESP of new model
Low ESP of new model
ESP (Pa)
› Flexible and easy to install in type-L, type-U and in large rooms
Model (kW)
) Fresh air function option for 5.6kW and above units
24
New structure: with buckles The new structure makes the disassembly convenient.
Former model
New model (In low ESP)
Sound level (dB(A))
Supply air duct
Model (kW)
) Key-card control
25
Duct Type (With drain water pump) MODEL
INV(L)-R22PS/NaB-K
Power supply Cooling (kW) Capacity Heating (kW) Power consumption (W) m3/h Airflow rate CFm Sound pressure level (H/M/L) (dB(A)) Standard Esp (H/L) (Pa) Dimensions (WxDxH) (mm) Net weight (Kg) Inch Gas (Flare) mm Connection pipe Inch Liquid (Flare) mm External dia. mm Drain Pipe Thickness mm
MODEL
2.2 2.5 75 450 265 37/35/33 50/20 28.5 3/8 φ9.52 1/4 φ6.35 φ20 1.5
INV(L)-R56PS/ NaB-K
INV(L)-R28PS/NaB-K
26
INV(L)-R36PS/NaB-K
1-Phase, 220-240V, 50Hz 2.8 3.6 3.2 4.0 80 80 570 570 335 336 39/37/35 39/37/35 50/20 50/20 800x600x250 30.5 30.5 3/8 1/2 φ9.52 φ12.7 1/4 1/4 φ6.35 φ6.35 φ20 φ20 1.5 1.5
INV(L)-R71PS/ NaB-K
Power supply Cooling (kW) Capacity Heating (kW) Power consumption (W) m3/h Airflow rate CFm Sound pressure level (H/M/L) (dB(A)) Standard Esp (H/L) (Pa) Dimensions (WxDxH) (mm) Net weight (Kg) Inch Gas (Flare) mm Connection pipe Inch Liquid (Flare) mm External dia. mm Drain Pipe Thickness mm
Duct Type (Without drain water pump)
5.6 7.1 6.3 8.0 240 240 1.000 1.100 589 647 44/42/40 45/43/41 60/30 60/30 1155x756x300 51 51 5/8 5/8 φ15.9 φ15.9 3/8 3/8 φ9.52 φ9.52 φ30 φ30 1.5 1.5
INV(L)-R90PS/ NaB-K 1-Phase, 220-240V, 50Hz 9.0 10.0 360 1.700 1.001 48/46/44 80/40 64 5/8 φ15.9 3/8 φ9.52 φ30 1.5
INV(L)-R45PS/NaB-K
MODEL
INV(L)-R22P/ NaB-K
Power supply 4.5 5.0 140 700 412 40/38/36 50/20 980x721x266 36 1/2 φ12.7 1/4 φ6.35 φ30 1.5
INV(L)-R112PS/ NaB-K
INV(L)-R140PS/ NaB-K
11.2 12.5 360 1.700 1.177 48/46/44 80/40 1425x736x300 64 5/8 φ15.9 3/8 φ9.52 φ30 1.5
14.0 15.0 500 2.000 1.177 50/48/46 100/50
Cooling (kW) Capacity Heating (kW) Power consumption (W) m3/h Airflow rate CFm Sound pressure level (H/M/L) (dB(A)) Standard Esp (H/L) (Pa) Dimensions (WxDxH) (mm) Net weight (Kg) Inch Gas (Flare) mm Connection pipe Inch Liquid (Flare) mm External dia. mm Drain Pipe Thickness mm
MODEL
2.2 2.5 75 450 265 37/35/33 50/20 27 3/8 φ9.52 1/4 φ6.35 φ20 1.5
INV(L)-R90P/ NaB-K
Power supply
65.5 5/8 φ15.9 3/8 φ9.52 φ30 1.5
Cooling (kW) Capacity Heating (kW) Power consumption (W) m3/h Airflow rate CFm Sound pressure level (H/M/L) (dB(A)) Standard Esp (H/L) (Pa) Dimensions (WxDxH) (mm) Net weight (Kg) Inch Gas (Flare) mm Connection pipe Inch Liquid (Flare) mm External dia. mm Drain Pipe Thickness mm
9.0 10.0 360 1.700 1.001 48/46/44 80/40 62 5/8 φ15.9 3/8 φ9.52 φ30 1.5
INV(L)-R28P/ NaB-K
INV(L)-R36PS/ NaB-K
1-Phase, 220-240V, 50Hz 2.8 3.6 3.2 4.0 80 80 570 570 335 336 39/37/35 39/37/35 50/20 50/20 800x655x250 28.5 28.5 3/8 1/2 φ9.52 φ12.7 1/4 1/4 φ6.35 φ6.35 φ20 φ20 1.5 1.5
INV(L)-R112P/ NaB-K 1-Phase, 220-240V, 50Hz 11.2 12.5 360 1.700 1.177 48/46/44 80/40 1425x736x300 62 5/8 φ15.9 3/8 φ9.52 φ30 1.5
INV(L)-R45P/ NaB-K 4.5 5.0 140 700 412 40/38/36 50/20 980x721x266 34 1/2 φ12.7 1/4 φ6.35 φ30 1.5
INV(L)-R140P/ NaB-K 14.0 15.0 500 2.000 1177 50/48/46 100/50 63.5 5/8 φ15.9 3/8 φ9.52 φ30 1.5
INV(L)-R56P/ NaB-K
INV(L)-R71P/ NaB-K
5.6 7.1 6.3 8.0 240 240 1.000 1.100 589 647 44/42/40 45/43/41 60/30 60/30 1155x756x300 49 49 5/8 5/8 φ15.9 φ15.9 3/8 3/8 φ9.52 φ9.52 φ30 φ30 1.5 1.5
INV(L)-R224P/ NaB-M
INV(L)-R280P/ NaB-M
3-Phase, 380-450V, 50Hz 22.4 28.0 25.0 31.0 1.600 1.600 4.000 4.800 2.354 2.825 56(H) 57(H) 200 220 1463x799x389 1500x920x450 88 125 7/8 7/8 φ22.2 φ22.2 3/8 3/8 φ9.52 φ9.52 φ25.4 φ25.4 1.5 1.5
27
SLIM DUCT TYPE ) Compact Design
)L ower noise
›2 .2kW, 2.8kW, 3.6Kw Only 700mm in width, 200mm in height and 22kg in weight*, which is perfect to install in limited spaces like drop ceiling in hotel.
Plastic propeller housing, fan blade and intelligent-designed air-channel ensure air flow volume with lower operation noise.
✍ • Note: the weight is 23kg for the unit of 3.6kW.
200mm
700mm
›4 .5kW, 5.6kW Only 200mm in height, which can be installed in rooms with little depth as 240mm depth between the drop ceiling and ceiling slab. Suspension bolt
For example the normal unit of 2.8kW has noise level up to 40dB(A), but the new unit of 2.8kW reduces the noise up to only 37dB(A).
Suction duct*
200mm
)D rain pump lift reaches 1000mm
AIR 900mm Discharge grille
Air filter
Suction grille
AIR
✍ • Note: to be obtained locally
)H ighly flexible installation MODEL
Highly flexible installation is possible to satisfy various needs.
INV(L)-R22P/ NaE-K
INV(L)-R28P/ NaE-K
2.2 2.5 64 450 265 37/35/33 20
2.8 3.2 64 450 265 37/35/33 20 700x615x200 21 3/8 φ9.52 1/4 φ6.35 φ20 1.5
Power supply
Installation examples Example 1
Example 2 Return air inlet
Supply air duct
Indoor unit
Supply air duct
Canvas air duct Indoor unit Long-life filter
28
Maintenance access
Long-life filter
Cooling (kW) Capacity Heating (kW) Power consumption (W) m3/h Airflow rate CFm Sound pressure level (H/M/L) (dB(A)) Standard Esp (Pa) Dimensions (WxDxH) (mm) Net weight (Kg) Inch Gas (Flare) mm Connection pipe Inch Liquid (Flare) mm External dia. mm Drain Pipe Thickness mm
21 3/8 φ9.52 1/4 φ6.35 φ20 1.5
INV(L)-R36P/ NaE-K
INV(L)-R45P/ NaE-K
INV(L)-R56P/ NaE-K
1-Phase, 220-240V, 50HZ 3.6 4.5 5.6 4.0 5.0 6.3 70 91 91 550 700 700 324 412 412 39/37/35 40/38/36 41/39/37 20 20 20 900x615x200 22 26 26 1/2 3/8 3/8 φ12.7 φ9.52 φ9.52 1/4 5/8 5/8 φ6.35 φ15.9 φ15.9 φ20 φ30 φ30 1.5 1.5 1.5
INV(L)-R71P/ NaE-K 7.1 8.0 100 1000 589 42/40/38 20 1100x615x200 20 3/8 φ9.52 5/8 φ15.9 φ30 1.5
29
FOUR WAY CASSETTE TYPE Common characteristics › Low noise with 3 – dimensional blade.
Diffuser
3-dimensional blade
) Four-way Cassette Type ›C ompact, light weight and square panel in the same size for easy installation.
Compact Four-way Cassette Type › Compact size of 650mm x 650mm for 2.8kW – 5.6kW
650mm
960mm
› The full-automatic operation, the 4-way air supply, the 3-speed fan setting and the strong circulating air flow volume, make the cooled or heated air to reach directly every corner of the room. This can be succeded even if the ceiling is higher than standard height.
960mm
› A slim unit below 5.0kW is only 190mm in thickness. It can be installed in a narrow ceiling space of at least 210mm.
• A unit below 7.1kW is applicable to height below 3m.
• The units above 8kW are applicable to height below 4.5m.
650mm
› Only 230mm in thickness that can be installed in a ceiling space of at least 250mm.
› Air supply in different directions with 30-60 degree sweep for even better temperature distribution* ›D rain pump fitted as standard with increased lift of 1100mm.
›D rain pump fitted as standard with increased lift of 500mm.
✍ Note: the guide louver defaults to min. position of 30° during cooling, dry and fan operation, or maximum position of 60° during heating operation.
› Designed with fresh air baffle for fresh air introduction.
30
› L ong life and washable filter.
31
Four-Way Cassette Type MODEL Power supply
INV(L)-R28T/Na-K
Cooling (kW) Heating (kW) Power consumption (W) m3/h Aiflow rate CFm Sound pressure level (H/M/L) (dB(A)) Capacity
Connection pipe Drain Pipe Main body Panel
Gas (Flare) Liquid (Flare)
Inch mm Inch mm
External dia. (mm) Thickness (mm) Dimensons (WxDxH) (mm) Net Weight (kg) Dimensons (WxDxH) (mm) Net Weight (kg)
2.8 3.2 65 680 400 37/35/34 3/8 φ9.52 1/4 φ6.35 φ30 1.5 25 6.5
Four-Way Cassette Type INV(L)-R36T/Na-K
INV(L)-R45T/Na-K
1-Phase, 220-240V, 50HZ 3.6 4.5 4.0 5.0 65 65 680 680 400 400 37/35/34 37/35/34 1/2 1/2 φ12.7 φ12.7 1/4 1/4 φ6.35 φ6.35 φ30 φ30 1.5 1.5 840x840x190 25 25 950x950x60 6.5 6.5
INV(L)-R50T/Na-K 5.0 5.8 65 680 400 37/35/34 1/2 φ12.7 1/4 φ6.35 φ30 1.5 25 6.5
MODEL Power supply
INV(L)-R100T/Na-K
Cooling (kW) Heating (kW) Power consumption (W) m3/h Aiflow rate CFm Sound pressure level (H/M/L) (dB(A)) Capacity
Connection pipe Drain Pipe Main body Panel
Gas (Flare) Liquid (Flare)
Inch mm Inch mm
External dia. (mm) Thickness (mm) Dimensons (WxDxH) (mm) Net Weight (kg) Dimensons (WxDxH) (mm) Net Weight (kg)
10.0 11.0 133 1.860 1.095 39/37/35 5/8 φ15.9 3/8 φ9.53 φ30 1.5 38 6.5
INV(L)-R112T/Na-K
INV(L)-R125T/Na-K
1-Phase, 220-240V, 50HZ 11.2 12.5 12.5 13.5 133 133 1.860 1.860 1.095 1.095 40/38/36 40/38/36 5/8 5/8 φ15.9 φ15.9 3/8 3/8 φ9.52 φ9.52 φ30 φ30 1.5 1.5 840x840x320 38 38 950x950x60 6.5 6.5
INV(L)-R140T/Na-K 14.0 14.5 133 1.860 1.095 40/38/36 5/8 φ15.9 3/8 φ9.52 φ30 1.5 38 6.5
Compact Four-Way Cassette Type MODEL Power supply
INV(L)-R56T/Na-K
Cooling (kW) Heating (kW) Power consumption (W) m3/h Aiflow rate CFm Sound pressure level (H/M/L) (dB(A)) Capacity
Connection pipe Drain Pipe Main body Panel
32
Gas (Flare) Liquid (Flare)
Inch mm Inch mm
External dia. (mm) Thickness (mm) Dimensons (WxDxH) (mm) Net Weight (kg) Dimensons (WxDxH) (mm) Net Weight (kg)
5.6 6.3 83 1.180 695 39/37/35 5/8 φ15.9 3/8 φ9.52 φ30 1.5 30 6.5
INV(L)-R71T/Na-K
INV(L)-R80T/Na-K
1-Phase, 220-240V, 50HZ 7.1 8.0 8.0 8.8 83 83 1.180 1.180 695 695 39/37/35 39/37/35 5/8 5/8 φ15.9 φ15.9 3/8 3/8 φ9.52 φ9.52 φ30 φ30 1.5 2.5 840x840x240 30 30 950x950x60 6.5 6.5
INV(L)-R90T/Na-K 9.0 10.0 133 1.860 1.095 39/37/35 5/8 φ15.9 3/8 φ9.52 φ30 3.5 840x840x320 38 6.5
MODEL Power supply
INV-R22T/NaA-K
Cooling (kW) Heating (kW) Power consumption (W) m3/h Aiflow rate CFm Sound pressure level (H/M/L) (dB(A)) Capacity
Connection pipe Drain Pipe Main body Panel
Gas (Flare) Liquid (Flare)
Inch mm Inch mm
External dia. (mm) Thickness (mm) Dimensons (WxDxH) (mm) Net Weight (kg) Dimensons (WxDxH) (mm) Net Weight (kg)
2.2 2.5 12 600 353 47/44/41 3/8 φ9.52 1/4 φ6.35 φ30 1.5 25 5
INV-R28T/NaA-K
INV-R36T/NaA-K
1-Phase, 220-240V, 50HZ 2.8 3.6 3.2 4.0 12 12 600 600 353 353 47/44/41 47/44/41 1/2 1/2 φ12.7 φ12.7 1/4 1/4 φ6.35 φ6.35 φ30 φ30 1.5 1.5 570x570x230 25 25 650x650x50 5 5
INV-R45T/NaA-K 4.5 5.0 12 600 353 47/44/41 1/2 φ12.7 1/4 φ6.35 φ30 1.5 25 5
33
ONE-WAY CASSETTE TYPE
FLOOR STANDING TYPE
)H igh flexible
)D rain pump lift
› Highly flexible installations for various needs.
› Drain pump flitted as standard with increased lift of 700mm.
)T he unit is applicable to height below 3.5m
)D etachable and washable grille
)U ltra quiet operation
) Comfortable
Low noise cross flow fan reduces vortex flow in the duct thus reducing the noise.
The equal and gentle air supply design and the advanced air flow controlling design make the room temperature equal and balanced. So, the people inside the room feel more comfortable.
Wireless FCU Wired remote controller WK-010PA-K
• Auto diagnosis • Fashionable and novel appearance • Quiet operation • Intelligent drainage device • Long life filter • Wider air supply and swing angle • Dynamic color display
)L ong life and washable filter MODEL Power supply
INV(L)-R22Td/NaA-K
Cooling (kW) Heating (kW) Power consumption (W) m3/h Aiflow rate CFm Sound pressure level (dB(A)) Capacity
Connection pipe Drain Pipe Main body Panel
34
Gas (Flare) Liquid (Flare)
Inch mm Inch mm
External dia. (mm) Thickness (mm) Dimensons (WxDxH) (mm) Net Weight (kg) Dimensons (WxDxH) (mm) Net Weight (kg)
2.2 2.5 42 450 265 45 3/8 φ9.52 1/4 φ6.35 φ30 1.5 16 3
INV(L)-R28Td/NaA-K 1-Phase, 220-240V, 50HZ 2.8 3.2 42 500 294 45 3/8 φ9.52 1/4 φ6.35 φ30 1.5 920x360x185 16 1180χ430χ30 3
INV(L)-R36Td/NaA-K 3.6 4.0 42 500 294 45 1/2 φ12.7 1/4 φ6.35 φ30 1.5 16
Model / Heat pump Capacity
Cooling Heating
Power supply Motor power input Air flow volume Sound pressure level Connecting pipe Drain pipe Dimensions Net Weight
Gas Liquid External dia. Thickness WxDxH Body
kW kW V/Ph/Hz W m3/h CFM dB(A) inch inch mm mm mm kg
INV-R71L/Na-K
INV-R100L/Na-K
INV-R140L/Na-K
7.00 8.00 220-240/1/50 150 1100/1000/920 655/595/548 48/45/42 5/8 3/8 31 4.5 502x316x1756 39.0
10.00 11.00 220-240/1/50 330 1600/1500/1300 952/893/774 51/49/47 5/8 3/8 31 4.5 556x381x1896 53
14.00 15.00 220-240/1/50 330 1700/1600/1400 1012/952/833 52/50/48 5/8 3/8 31 4.5 556x381x1896 57
3
35
MODEL
INV(L)-R22G/ NaB-K
INV(L)-R28G/ NaB-K
Power supply Cooling (kW) Capacity Heating (kW) Power consumption (W) m3/h CFm Sound pressure level (H/M/L) (dB(A)) Dimensions (WxDxH)(mm) Net weight (kg) Inch Gas (Flare) mm Connection pipe Inch Liquid (Flare) mm External dia. (mm) Drain Pipe Thickness (mm) EXV Position Aiflow rate
WALL MOUNTED TYPE
) Streamlined design for spaces without ceiling
MODEL
) Anti cool air design
) Vertical auto swing
When heating in winter, intelligent anti cool air function is started.The unit blows only when the unit is pre-heated inside, to prevent it from blowing out cool air.
When cooling, the cool air is directed across the room and then it sinks. When heating, the warm air is directed across the floor and then it rises. Cooling
Heating
) Auto clean (under COOL & DRY mode)
) Low noise design
After the unit is turned off, the indoor fan will still operate in low speed in order to dry the inner components and parts. This way mould and odor are prevented from growing.
The advanced irregular-distance mixed flow fan, the unique duct design and the multi-grill auxiliary duct, make the operation highly efficient and the noise lower.
2.2 2.8 2.5 3.2 32 32 360 360 212 212 37/33/28 37/33/28 770x190x250 8 8 3/8 3/8 φ9.52 φ9.52 1/4 1/4 φ6.35 φ6.35 φ20 φ20 1.5 1.5
INV(L)-R71G/ NaB-K
Power supply Cooling (kW) Capacity Heating (kW) Power consumption (W) m3/h CFm Sound pressure level (H/M/L) (dB(A)) Dimensions (WxDxH)(mm) Net weight (kg) Inch Gas (Flare) mm Connection pipe Inch Liquid (Flare) mm External dia. (mm) Drain Pipe Thickness (mm) EXV Position Aiflow rate
MODEL
7.1 8.0 8.0 9.0 63 65 1.200 1.200 706 706 49/45/42 49/45/42 1178x227x326 17.5 17.5 5/8 5/8 φ15.9 φ15.9 3/8 3/8 φ9.52 φ9.52 φ30 φ30 1.5 1.5 External
INV(L)-R50G/ NaG-K
Power supply Cooling (kW) Capacity Heating (kW) Power consumption (W) m3/h CFm Sound pressure level (H/M/L) (dB(A)) Dimensions (WxDxH)(mm) Net weight (kg) Inch Gas (Flare) mm Connection pipe Inch Liquid (Flare) mm External dia. (mm) Drain Pipe Thickness (mm) EXV Position Aiflow rate
) Ternary filters Ternary air filters with anti-mildew, static electric dust capture and anti-bacterial function.
) Washable grille The front grille can be easily removed for washing.
36
Ternary filter
INV(L)-R80G/ NaB-K
5.0 5.8 38 630 371 44/41/38 940x200x298 13 1/2 φ12.7 1/4 φ6.35 φ28 4
INV(L)-R36G/ NaB-K
INV(L)-R45G/ NaB-K
INV(L)-R50G/ NaB-K
1-Phase, 220-240V, 50HZ 3.6 4.5 4.0 5.0 48 48 500 500 294 294 43/35/28 43/35/28 830x189x285 11 11 1/2 1/2 φ12.7 φ12.7 1/4 1/4 φ6.35 φ6.35 φ20 φ20 1.5 1.5 External
INV(L)-R22G/ NaG-K
INV(L)-R28G/ NaG-K
INV(L)-R56G/ NaB-K
5.0 5.6 5.8 6.3 56 58 700 750 412 441 45/42/40 45/42/40 1020x228x310 15 15 1/2 5/8 φ12.7 φ15.9 1/4 3/8 φ6.35 φ9.52 φ30 φ30 1.5 1.5
INV(L)-R36G/ NaG-K
INV(L)-R45G/ NaG-K
1-Phase, 220-240V, 50HZ 2.2 2.8 3.6 4.5 2.5 3.2 4.0 5.0 37 37 38 38 500 500 630 630 294 294 371 371 38/36/34 39/36/34 44/41/38 44/41/38 843x180x275 940x200x298 10.5 10.5 13 13 3/8 3/8 1/2 1/2 φ9.52 φ9.52 φ12.7 φ12.7 1/4 1/4 1/4 1/4 φ6.35 φ6.35 φ6.35 φ6.35 φ28 φ28 φ28 φ28 4 4 4 4 Intergrated
INV(L)-R56G/ NaG-K
INV(L)-R63G/ NaG-K
1-Phase, 220-240V, 50HZ 5.6 6.3 6.3 7.0 60 60 800 800 471 471 44/41/38 44/41/38 1008x221x319 15 15 5/8 5/8 φ15.9 φ15.9 1/4 1/4 φ6.35 φ6.35 φ28 φ28 4 4 Integrated
INV(L)-R71G/ NaG-K 7.1 8.0 60 800 471 44/41/38 15 5/8 φ15.9 1/4 φ6.35 φ28 4
37
) Easy maintenance Convenient disassembly and maintenance thanks to unique design. › Plastic filter with buckles › Grill buckle
› Dismountable motor
FLOOR CEILING TYPE ) Compact and light weight
Only 238mm in height
) Wide discharge range With cross-direction sweep. The air supply range is efficiently wider.
) Ultra quiet operation
) Long life, detachable and washable grille
) Drain pump lift reaches 1100mm
) Easy to install and good looking, satisfies more requirements
38
39
Floor ceiling (EXV Separated) MODEL
INV(L)-R28Zd/Na-K
Power supply Cooling (kW) Capacity Heating (kW) Power consumption (W) m3/h CFm Sound pressure level (H/M/L) (dB(A)) Dimensions (WxDxH) (mm) Net weight (kg) Inch Gas (Flare) mm Connection pipe Inch Liquid (Flare) mm External dia. (mm) Drain Pipe Thickness (mm) Aiflow rate
MODEL
2.8 3.2 22 550 324 43/40/38 28 3/8 φ9.52 1/4 φ6.35 φ17 1.75
INV(L)-R90Zd/Na-K
Power supply Cooling (kW) Capacity Heating (kW) Power consumption (W) m3/h CFm Sound pressure level (H/M/L) (dB(A)) Dimensions (WxDxH) (mm) Net weight (kg) Inch Gas (Flare) mm Connection pipe Inch Liquid (Flare) mm External dia. (mm) Drain Pipe Thickness (mm) Aiflow rate
40
8.0 10.0 330 2.100 1.236 51/48/44 1590x238x695 44 5/8 φ15.9 3/8 φ9.52 φ17 1.75
Floor ceiling (EXV Integrated) INV(L)-R36Zd/Na-K
INV(L)-R50Zd/Na-K
1-Phase, 220-240V, 50HZ 3.6 5.0 4.0 5.8 22 90 600 700 353 412 44/41/38 50/47/44 840x238x695 28 28 1/2 1/2 φ12.7 φ12.7 1/4 1/4 φ6.35 φ6.35 φ17 φ17 1.75 1.75
INV(L)-R112Zd/Na-K 1-Phase, 220-240V, 50HZ 11.2 12.5 340 2.200 1.295 54/50/46 1714x330x830 44 5/8 φ15.9 3/8 φ9.52 φ17 1.75
INV(L)-R71Zd/Na-K
MODEL
INV(L)-R28Zd/NaB-K
Power supply 7.1 8.0 220 1.170 689 48/45/43 1300x188x600 33 5/8 φ15.9 3/8 φ9.52 φ17 1.75
INV(L)-R125Zd/Na-K
Cooling (kW) Capacity Heating (kW) Power consumption (W) m3/h CFm Sound pressure level (H/M/L) (dB(A)) Dimensions (WxDxH) (mm) Net weight (kg) Inch Gas (Flare) mm Connection pipe Inch Liquid (Flare) mm External dia. (mm) Drain Pipe Thickness (mm) Aiflow rate
MODEL
2.8 3.2 19 500 324 43/40/38 27 3/8 φ9.52 1/4 φ6.35 φ17 1.75
INV(L)-R90Zd/NaB-K
Power supply 12.5 13.5 340 2.300 1.354 55/51/47 44 5/8 φ15.9 3/8 φ9.52 φ17 1.75
Cooling (kW) Capacity Heating (kW) Power consumption (W) m3/h CFm Sound pressure level (H/M/L) (dB(A)) Dimensions (WxDxH) (mm) Net weight (kg) Inch Gas (Flare) mm Connection pipe Inch Liquid (Flare) mm External dia. (mm) Drain Pipe Thickness (mm) Aiflow rate
8.0 9.0 200 1.700 1.000 51/48/44 1420x700x245 32 5/8 φ15.9 3/8 φ9.52 φ17 1.75
INV(L)-R36Zd/NaB-K
INV(L)-R50Zd/NaB-K
1-Phase, 220-240V, 50HZ 3.6 5.0 4.0 5.8 19 75 600 700 353 412 44/41/38 50/47/44 980x700x225 27 27 1/2 1/2 φ12.7 φ12.7 1/4 3/8 φ6.35 φ9.52 φ17 φ17 1.75 1.75
INV(L)-R112Zd/NaB-K
INV(L)-R125Zd/NaB-K
1-Phase, 220-240V, 50HZ 11.2 12.5 12.5 13.5 300 300 2.000 2.000 1.777 1.777 54/50/46 54/50/46 1700x700x245 62 66 5/8 5/8 φ15.9 φ15.9 3/8 3/8 φ9.52 φ9.52 φ17 φ17 1.75 1.75
INV(L)-R71Zd/NaB-K 7.1 8.0 150 1.500 883 48/45/43 1420x700x245 32 5/8 φ15.9 3/8 φ9.52 φ17 1.75
INV(L)-R140Zd/NaB-K 14.0 16.0 300 2.000 1.777 54/50/46 66 5/8 φ15.9 3/8 φ9.52 φ17 1.75
41
) Easy control › Wired remote control
› Wireless remote control
›C entralized control
› Long-distance monitoring
› Sub-room switch
›M emory function
› Auto restart after power recover
›W eekly timer
TREATED FRESH AIR DUCT TYPE
) Flexible application
)P rovide fresh air of temperature that is close to the indoor ambient, ensures fresh and comfortable indoor air. ✍
› The standard pressure is 200Pa and the optional range is 50-300Pa.
› T he indoor unit with high static pressure can realize long-distance fresh air supply to all corners of the room. So, it is greatly applicable to places that there is high density of people.
Note: The capacity of fresh air ducted unit should be less than 30% of the capacity of outdoor unit.
MODEL Power supply Capacity (At rated ESP) Power input1 Aiflow Volume
) Comfortable › Makes you feel comfortable, like in the nature. It is introducing the outdoor fresh air, after treatment, in to the room.
42
› T reated fresh air supplying temperature is close to the indoor temperature (factory setting at 22 Celsius), reducing the cooling load of other indoor units.
Cooling (kW) Heating (kW) Cooling (kW) Heating (kW) CFm m3/h
Sound pressure level (H/M/L) (dB(A)) Rated (Pa) External Static Pressure Range (Pa) Dimensions (WxDxH) (mm) Weight (kg) Valve Connection Type Length (m) Connection pipe Gas additional charge (g/m) Liquid Pipe (Inch) Gas pipe (Inch)
INV-R140P/ Na(X1.2)-K
INV-R224P/ Na(X2.0)-M
INV-R280P/ Na(X2.5)-M
INV-R280P/ Na(X3.0)-M
220-50-1 14 10 0.5 0.5 706 1200 42 150 50~150 1463x756x300 49 Flare Connection 7.5 54 3/8 5/8
380-50-3 22.4 16 1.1 1.1 1177 2000 47 200 50~200 1700x1100x650 130 Brazing Connection 7.5 54 3/8 11/9
380-50-3 28 20 1.1 1.1 1472 2500 48 200 50~200 1700x1100x650 150 Brazing Connection 7.5 54 3/8 8/9
380-50-3 28 20 1.1 1.1 1766 3000 51 200 50~200 1700x1100x650 150 Brazing Connection 7.5 54 3/8 8/9
43
CONTROL NETWORK SKETCH Air Conditioning Individual Control
System
Communication module ME30-00/E2
Group Controller ZJA011
Air Conditioning Central Control RS-232 to RS-422/485 Converter
Building Management
INVENTOR AC Eudemon 2009 (Monitoring Software)
FE30-00/A(M)
Module link Transmission line (INV network) Group controller line Remote Controller line
RS-232 to RS-422/485 Converter
Modbus network
Web Monitoring Client
Wired Remote Controller Z63351F/Z63151F Z60351F/Z60151F
IR receiver line Key-card control board line
Internet
Key-card signal line
Communication module ME30-00/E2 Wired Remote Controller ZX60451
Web Monitoring Client
Wireless Remote Controller YB1FA Y512
RS-422/485 Repeater
Communication module ME30-00/E2 Centralized Controller CE51-24/E(M)
Smart Zone Controller CE50-24/E Key-card Control Board MK03
Building Management System
Key-card
IR Receiver Unit JS01
✍ Note: • Control network sketch is for reference only, please refer to the equipment manuals for actual cable connection method.
44
(Field supplied)
BMS Interface (Modbus) ME30-00/E2
Commissioning Program (Software) Text Parser
45
COMMENTS OF CONTROL FUNCTIONS
CONTROLLERS COMPARISON ITEM
Max Nos. of Outdoor Units Connections
Control functions
Display
Shielding
Centralized Control
) ON/OFF Timer Function
) Sleeping Function
Under ON/OFF state, set the unit to be automatically turned on or turned off in 0.5h hours (1≤n