Gradual polymerization: Exposure for 4 minutes with a slow rise of the intensity ... not differ significantly from group B (M= 1.63, SD= 1.351, p=0.767), and group ...
Nov 1, 2010 - 2 School of Dental Technology, Hacettepe University, Ankara, Turkey ... were cured with three light curing units (LCUs) in different modes on ...
the high-powered LED LCU, which ensures that no excessive heat is produced by all the three curing modes. Key words: Temperature rise, Composites, ...
and 5 mm diameter) were prepared from different dual-curing resin cements ... was tested in a universal testing machine at a crosshead speed of 0.5 mm/min.
Prosthodontics, School of Dentistry, Oeste ... high degree of conversion when photoactivated with this type of units.4 ... Micro Etcher, Syosset, NY, USA) for 10 s.
specimens were loaded in tensile strength until fracture in a universal testing machine at a ... resin shade, curing time, light-curing unit, irradiance, emitted.
Three different classes of commercial dental composites were tested: 1) traditional composites (Prodigy, KerrHawe SA,. Bioggio, Switzerland; Z 250, 3M ESPE, ...
Mar 27, 2012 - cemented with a dual-cure resin cement. Four groups were formed ... with QTH LCU (Optilux 501, Kerr, Orange, CA, USA) at a light intensity not ...
PMCRs subsequently absorb water, which results in ionization of the monomers and the production of hydrogen ions with light-curing. Compomers are similar to ...
William Cunha Brandt(a). Luis Felipe ... significantly lower DC values than composites with CQ when irradiated with QTH. ..... Cook WD, Chong MP. Colour ...
different light densities of halogen (H) and Light Emitting Diod (LED) curing units. ..... Curing depths of a universal hybrid and a flowable resin composite cured ...
prosthetic or restorative treatment (1). The retention of glass-fiber-reinforced posts is ... coronal, middle and apical post/root regions were submitted to the push-out test ... Higher adhesion of the resin cement to intraradicular dentin was observ
Received 2 October 2011; revised 22 November 2011; accepted 31 January 2012. Available ... Temperature changes were recorded in continues 10 and 20 s intervals up to 300 s. Results: ... temperature rise than LED curing units of the same power density
Spectral Characteristics of Light-curing Units and. Dental Adhesives. Author(s). Alternative. Kameyama, A; Hatayama, H; Kato, J; Haruyama, A;. Teraoka, H ...
advertisements, websites or manufacturers' catalogues. Sometimes ... curing meter, microprocessor and battery charger. (13). WHAT ARE ... came from other industry such as ink, paint and .... 10,000 hours and can be subjected to mechanical.
Uniterms: Light-curing modes; Composite resins; Staining; Storage media. INTRODUCTION. Dental composite resin is the most frequently used direct.
Sep 14, 2012 - Abstract: The aim of this study was to evaluate the effects of different light-curing units and resin cement curing types on the bond durability.
in cotyledon derived calli increased browning. The results of this ... M2. NAA 1 mg l-1; BA 1 mg l-1. MS. M3. NAA 1 mg l-1; BA 1 mg l-1. 1/2MS. M4. 2, 4-D 1 mg ...
Objective. To test the hypothesis that a prototype LED light curing unit,. (LCU), a commercial LED LCU and a halogen LCU achieve similar cure depths, using ...
chamber induced by halogen, plasma arc, and conventional light-emitting diode. (LED) curing units with that induced via a new generation LED-curing unit ...
Objective. To test the hypothesis that a prototype LED light curing unit,. (LCU), a commercial LED LCU and a halogen LCU achieve similar cure depths, using ...
various distances between the light curing tip and the radiometer Cure Rite Denstply (0,1,3,5,10 and 15 mm). The light curing units were tested at right angles to ...
Problem: The irradiance from dental light-curing units (LCUs) is commonly reported ... §Research Assistant, Department of Dental Clinical Sciences, Dalhousie ...
whilst the commercial LED had the lowest values and was the only one that did not reach an adequate level of polymerisation for the darker shade composite.
Effects of Different Light Curing Units/ Modes on the ... - CiteSeerX
units and modes on microleakage of flowable composite resins. ... Conclusions: The effect of curing units' type and curing mode on flowable composite resin ...
Effects of Different Light Curing Units/ Modes on the Microleakage of Flowable Composite Resins A. Ruya Yazicia Cigdem Celikb Berrin Dayangacc Gul Ozgunaltayc Objectives: The aim of this in vitro study was to evaluate the influence of different light curing units and modes on microleakage of flowable composite resins. Methods: Eighty Class V cavities were prepared in buccal and lingual surfaces of 40 extracted human premolars with cervical wall located in dentin and the occlusal wall in enamel. These teeth were randomly assigned into two groups (n=20) and restored with different flowable composites; Group I: Esthet-X Flow, Group II: Grandio Flow. Each group was randomly divided into four subgroups; while the samples of the first subgroup were polymerized with conventional Halogen light, the rest of them were polymerized with different curing modes of Light Emitting Diode (LED). The second subgroup was polymerized with fast-curing; the third subgroup with pulse-curing and those of the fourth subgroup with step-curing modes of LED. After the samples were thermocycled and immersed in dye, they were longitudinally sectioned. Dye penetration was assessed under a stereomicroscope. Data were analyzed by Kruskal-Wallis and Mann-Whitney U tests. Results: None of the restorations showed leakage on enamel margins. On dentin margins no significant differences were observed between flowable composite resins polymerized with halogen light (P>.05). While step curing mode of LED presented significant differences between the resins, the difference was insignificant when fast-curing and pulse-curing mode of LED were used. No statistically significant differences were observed between curing units for Esthet-X Flow samples. For Grandio Flow samples, only step-curing mode of LED caused statistically higher leakage scores than halogen and other curing modes of LED (P.05). While fast-curing and pulse-curing modes
Table 1. Flowable composite resins and compositions. Filler Product
Composition
Volume w/w %
Volumetric
Average Filler Particle Size (μm)
Polymerization Shrinkage (%)
Urethane modified BisEsthet-X Flow
GMA-adduct,BisGMA
(Dentsply/Caulk, Milford, DE, USA)
Barium fluoro amino-
Batch # 548012
61
0.85-0.9
3-3.5
boro silicate glass, nanofiller silica
GrandioFlow (Voco, Cuxhaven, Germany)
SiO2-nanoparticles Bis-GMA, TEGDMA, HEDMA
Batch # 441042
80.2
(40 nm) glass ceramic fillers (1 µm)
Table 2. Light curing units used in this study. Light-curing units
Modes
Light-intensity
Halogen Hilux 200
400 mW/cm2
Standard
(40 sn)
(Hilux, Benlioglu, Ankara,Turkey)
LED Mini LED (Mini LED, Satelec, France)
European Journal of Dentistry
(10 sn) 1100 mW/cm2
Pulse-curing Step-curing
242
1100 mW/cm2
Fast-curing
(10x1 sn) 0-1100 mW/cm2 → (10 sn)
1100 mW/cm2 (10 sn)
3.2
Yazici, Celik, Dayangac, Ozgunaltay
of LED presented no statistical differences between the resins (P>.05), the difference was significant when step-curing mode of LED were used (P.05). For Grandio Flow samples only step-curing mode of LED caused statistically higher leakage scores than halogen and other curing modes of LED (P