99. 4. EGX100. 1 24 Vdc power connection. 2 10/100 Base TX (802.3af) port for
connection to Ethernet via an RJ45 connector. 3 Ethernet and serial indication ...
Converters
DB109282
EGX100
EthernetEGX100gateway EthernetEGX400server
Characteristics
EGX100
EGX400
Weight Dimensions (H x W x D) Mounting
170 g 91 x 72 x 68 mm Din rail
Power-over-Ethernet (PoE) Power supply
Class 3 24 V DC if not using PoE
Operating temperature Humidity rating
-25 °C to +70°C 5 % to 95 % relative humidity (without condensation) at +55 °C
700 g 25 x 190 x 115 mm Symmetrical or asymmetrical DIN rail Front or side position None 24 V DC 100-240 V AC/24 V DC adapter supplied -30 °C to +80°C 5 % to 95 % relative humidity (without condensation) at +40 °C
Regulatory/standards compliance for electromagnetic interference
1 2 3 4 5 6 7 8
24 Vdc power connection. 10/100 Base TX (802.3af) port for connection to Ethernet via an RJ45 connector. Ethernet and serial indication LEDs. Power/Status LED. Reset button. RS485 connection. Dip switches for biasing, termination, and 2-wire/4-wire jumpers. RS232 connection.
EGX400
Emissions (radiated and conducted) Immunity for industrial environments: - electrostatic discharge - radiated RF - electrical fast transients - surge - conducted RF - power frequency magnetic field
EN 55022/EN 55011/ FCC class A EN 61000-6-2
EN 55022/FCC class A
EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8
EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-8 EN 61000-4-11
EN 61000-6-2
4
Regulatory/standards compliance for safety International (CB scheme) USA Canada Europe Australia/New Zealand
IEC 60950 UL508/UL60950 cUL (complies with CSA C22.2, no. 60950) EN 090 AS/NZS25 60950
UL0 cUL (complies with CSA C22.2, no. 14-M91)
Serialports RS232 or RS485 (2-wire or 4wire), depending on settings
Protocol
Modbus RTU/ASCII PowerLogic® (SY/MAX) 00 or 00 baud depending on settings
DB100978
Number of ports Types of ports
Power connector. Ethernet indication LEDs. 10/100 Base TX port for connection to Ethernet via an RJ45 connector. 4 100 Base FX port for connection to Ethernet via fiber optic cable (LC connector). 5 COM1: terminal block for RS485 serial link. 6 COM1 indication LEDs. 7 COM2: terminal block for RS485 serial link. 8 COM2 indication LEDs. 9 Dip-switches for setup of COM1 and COM2 ports bias and termination. 10 COM2: Sub D-9 connector for the RS232 serial link. 1 2 3
Maximum baud rate Maximum number of directly connected devices
COM1: RS485 (2-wire or 4-wire) COM2: RS232 or RS485 (2-wire or 4-wire), depending on settings Modbus RTU/ASCII PowerLogic® (SY/MAX) 00 baud 32 per port, 64 in all
Ethernetport Number of ports Types of ports
One 10/100 base TX (802.3af) port
Protocol
HTTP, SNMP, FTP, Modbus TCP/IP 10/100 MB
One 10/100 base TX port One 100 base FX port (multimode optic fiber) HTTP, SNMP, SMTP, SNTP, FTP, Modbus TCP/IP 10/100 MB