Fuel Gas Systems Catalog (ENG) - Pietro Fiorentini
Recommend Documents
Aug 30, 2012 ... The scope of this license includes the following product: Valves at PSL 1 through
3. QMS Exclusions: No Exclusions Identified as Applicable.
Service Kit. Includes: ... *Contact Customer Service For Customized Kits ..... 1092.
120 Volt, 50/60 Hz, 6000 Volt Secondary, 25/20mA, One End Ground. 1112.
Considering the collective anomalous data and both sensitivity and robustness of ... Keywords: gas turbine fuel system; anomaly detection; symbolic dynamic ..... biggest and then add the state into the path until the end of the sequence.
Aviation fuel is a liquid containing chemical energy that .... of the fuel system. For
this reason, aromatic-resistant hose and rubber parts have been developed for
use .... an aircraft fuel system. ...... A schematic diagram of a typical engine-dr
Jan 24, 2014 ... Use of fuel fill kits as provided by Ram Trucks is recommended. ... to Dodge
Service Manual for proper system fill procedures and service.
Jan 19, 2018 - Outstanding Equity Awards at Fiscal 2017 Year-End. 48 ... The Company and the U.S. natural gas industry i
two rear-wheel drive and double speed: - transfer speed 30 km/h;. - working speed 12 km/h;. - max slope 30%. - cabin wit
For high-performance maneuvers up to +9 Gs and to help prevent G-induced loss
of consciousness. (GLOC), the ..... Using specially developed dyes and colors,
Gentex also offers Amber and Neutral Gray lenses to enhance visual .... state-of-
the art,
Marine Hose. & Fittings .... (4) Vacuum installation only. For accurate .... Suzuki,
SMI, Volvo Penta, Sierra AquaPower .... module (for vacuum side applications
only) was .... WFC-S60. WFA12-T5. Taste and Oder Removal, 5 micron. WFC-T5.
15. W. A
Parts catalog news ini berisi daftar parts Honda Vario 2010, Honda Vario Techno
... catalog Honda Vario 2006, Honda Vario 2007 dan Honda Vario CBS 2009.
Fuel Gas Systems Catalog (ENG) - Pietro Fiorentini
Usually composed of a small skid mounted unit with one actuated ball valves
next ... Custody transfer metering skids are used for invoicing at the delivery point
...
Fuel Gas Systems
Power Plant
Power Plant
Pietro Fiorentini thanks to 70 years experience with Natural Gas equipment design and manifacturing is able to provide the complete fuel gas system for the gas sypply to the GT (Gas Turbines). The plus we can offer is the advantage to have one single supplier for all the mechanical and electrical equipment complete of the supervision system.
Inlet Section
Power Plant
ESD (Emergency Shut Down) Situated at the inlet of the Fuel Gas System it grants the closure of the flow into the pipe in case of an emergency. It can be remote/manually operated with different possibility for the re-opening and re-pressurizzation of the downstream lines. Usually composed of a small skid mounted unit with one actuated ball valves next to a manual gear operated one.
HIPPS (High Integrity Pressure Protection System) A certified SIL 3 (safety integrity level) skid can be used as ESD system in place of a simple ESD. Pietro Fiorentini can provide the HIPPS package complete of certifications, PFD report and SIL 3 issued by a third party.
Filtration
Power Plant
Pietro Fiorentini can design customized filters according to the design conditions and installation constrains.
• • • • • •
Single stage/ double stage Vertical/ horizontal Quick opening closure (QOC) Manual/ automatic drain Vent valves Condensate tank with manual/ automatic drain circuit
• • • • •
Drain level indicator/ transmitter and alarms Level switches DP indicators and transmitters Maximum efficiency, reliability with the lowest possible delta P across the filter Designe considering annular velocity limit and cartridges limit
Skid mounted with the possibility to be shiped separately are installed downstream the ESD and the KO DRUM, if present. They can remove both liquid or solid particles up to a maximum efficiency of 99,9% for particles up to 3 micron.
KO Drums
Power Plant
Placed after the ESD skid it is used as a single filter to remove the most heavy particles inside the gas. Thanks to the impingement or gravitational effect it is only used in case of dirty gas.
Filter type Gas - Solid separators • Cartridge filter • Mini cyclone separator Gas - Liquid separators • Demister (Wire Mesh) separator • Vane separator • Coalescer filter • Cyclotube Gas - Liquid - Solid separators • Two stage filter separators
Condensate tank
KO Drum
Metering skid
Vertical separators
Power Plant
Pietro Fiorentini can design and manufacture accurate metering system necessary for: • Custody transfer and invoicing • Measurement of generator efficiency Custody transfer metering skids are used for invoicing at the delivery point where gas is changing hands and every cubic meter of fluid has to be accurtely accounted for its delivery conditions such as pressure, temperature, energy values and contaminants. For this reason packages can be supplied complete of gas chromatograph and flow computer. We have experience in metering system with alternatives meters: ultrasonic, turbine or orifice.
Heating section
Power Plant
The heating section is needed for the following reasons: • Gas Dew Point heating: high-pressure natural gas heating upstream pressure regulation stations preventing condensation phenomena due to Joule-Thomson effect. • Heating of high pressure natural gas upstream pressure regulation in order to prevent external icing formation. • Fuel gas super-heating upstream gas turbines (Performance heaters)
Pressure control
Power Plant
Natural gas is usually highly pressurized as it travels through transport pipelines. But once it reaches the consumers, it needs to be brought up to the contractual specifications for delivery. This often means that solids and liquids have to be filtered out, the pressure has to be reduced, and the gas may need to be preheated to counteract the cooling effect of the pressure reduction. And last but not least, the downstream consumers need to be protected from being exposed to the full transport pipeline pressure. • • • • • • •
The regulator is the key item of the system Wide range of products Rubber produced internally Accurate supply pressure Quick response System redundancy Safety device for overpressure protection
Final filtration
Power Plant
Final filtration is composed of a vessel that removes all the liquid and solid particles contained in the fuel gas. The configuration is usually a single stage filter that can be composed of coalescing cartridges or in case of a scrubber of mini cyclones.
Performance heater
Power Plant
Higher efficiency power plants are increasing and a growing number of combined-cycle power plants are incorporating fuel gas performance heaters as a means of improving overall plant efficiency. This heating, typically increasing fuel temperatures in the range of 365°F/185°C up to more than 200°C, improves gas turbine efficiency by reducing the amount of fuel needed to achieve desired firing temperatures. Proper design and operation of the Gas Fuel Heating System is critical in insuring reliable operation of the gas turbine.
Turn Key projects
PIETRO FIORENTINI SERVICE
Commissioning – Start-up activities, Repairs, Spare Parts, Maintenance Program
Pietro Fiorentini Solutions
Turn Key Projects
Control Valves
Indirect Fired Heaters
Pietro Fiorentini S.p.A. via E.Fermi 8/10 I-36057 Arcugnano (VI) Italy
Tel. +39 0444 968.511 Fax. +39 0444 960.468
DA SISTEMARE !!!!!!!!
The data are not binding. We reserve the right to make eventual changes without prior notice.