Comply with IEC 60947-2. • 6 frame sizes: x160, x250, h250, h630, h1000, h1600
. • Breaking capacity: 25, 40, 50, 70kA. • Thermal magnetic and electronic trip ...
MCCB’s
16A to 1600A
MCCB’s Main switches
2
Expert tips -
MCCBs
characteristics
4
MCCBs
& accessories selection guide
6
MCCBs x160
10
MCCBs x250
12
MCCBs h250
14
MCCBs h630
16
MCCBs h1000
19
MCCBs h1600
21
MCCBs 16A to 1600A Easy mounting and safety The range of MCCBs provide safe and easy solutions for low voltage electrical circuit protection. The state of the art circuit breakers offer both designers and installers a wide range of features and benefits. With special attention being given to ergonomics, the range perfectly meets reliability requirements for main incoming devices in commercial premises: strength, reliability, efficient protection and standards compliant selection.
The advantages for you:
Technical data:
• Easy to install
• Comply with IEC 60947-2
• Quick, easy and safe mounting of accessories
• 6 frame sizes: x160, x250, h250, h630, h1000, h1600
• Wide range of rated current ratings and breaking capacities
• Breaking capacity: 25, 40, 50, 70kA
• Range of termination accessories
• Thermal magnetic and electronic trip units
• DIN rail profile up to 250A
• 1 pole to 4 poles • Current limiting type • Complete range of accessories • International certification and approvals
2
Expert tips 1 2 3 4
Design by Hager
In harmony with Hager enclosures and modular products.
Electronic trip unit (LSI) Provides total selectivity along with generator protection.
Breaking capacity
25 to 70kA, Icu 415V AC, covers all applications.
Easy auxiliary mounting
Easy opening of secondary cover, clip-in type auxiliaries.
5 6 7 8
Visibility of auxiliaries
A clear window indicates the type of auxiliary mounted in the breaker.
Integrated padlocking Provides a convenient solution for maintenance.
Full accessory range
Rotary handles, padlocks, motor operators, terminal covers...
Flexible connection
Collar terminals, front and rear connections, straight connections, spreaders...
3
MCCBs
characteristics
Product Reference Number of poles [No.] Electrical characteristics Rated current In [A] Current rated range [A] Rated service voltage, (AC) Ue [V] Frequency f [Hz] Rated insulation voltage Ui [V] Rated impulse withstand voltage Uimp [kV] Rated ultimate short-circuit breaking capacity, (Icu) (AC) 50-60 Hz 220/230 V Icu [kA]
x160 TM MCCB HHA 3-4
35
85
85
Rated
HNA
160 16-160 220-440 50/60 690 8
x250 TM MCCB HNB 3-4 250 100-250 220-440 50/60 800 8
(AC) 50-60 Hz 380/415 V Icu (AC) 50-60 Hz 480/500/525 V Icu (AC) 50-60 Hz 660/690 V Icu (DC) 250 V - 2 poles in series Icu service short-circuit breaking capacity, (Ics) (AC) 50-60 Hz 220/230 V Ics
[kA] [kA] [kA] [kA]
25 10
40 10
40 9
[kA]
25
40
40
(AC) 50-60 Hz 380/415 V Ics (AC) 50-60 Hz 480/500/525 V Ics (AC) 50-60 Hz 660/690 V Ics (DC) 250 V - 2 poles in series Ics Rated short-circuit making capacity Icm Rated short-time withstand current for 1s Icw Category of use (EN 60947-2) Calibration temperature Derating 40°C 50°C 55°C 60°C 65°C Suitability for isolation Electric endurance in number of cycles Mechanical endurance in number of operations Operating temperature Storage temperature Power loss (at In for 3P) Reference standard Releases: switch Releases: TM (thermomagnetic) T fixed, M fixed T adjustable, M fixed T adjustable, M adjustable Thermal adjustment value Magnetic adjustment value
[kA] [kA] [kA] [kA] [kA] [kA]
20
20
20
Releases: LSI (electronic) Long delay Short delay
-
5 A 50°C 100% 100% 94% 91% 88% ok 10000 20000 -25 to +70°C -35 to +70°C 60 IEC 60947-2 ok ok ok 0,63 to 0.8 to 1 x In 6-8-10-13 x In (200A) 5-7-9-11 In (250A) -
Time delay Terminations Standard terminal type Maximum terminal capacity Terminal width Terminal shields Cage terminal Extended connections Rear connections Dimensions Height mm Width 3P mm 4P mm Depth mm Weight 3P kg 4P kg
-
-
cage 95 mm2 ok integrated ok no
lugs 185 mm2 (cage) 25 ok ok ok ok
130 75 100 68 0,715 0,95
165 105 140 68 1,3 1,6
4
[W]
mm
5 5 A 50°C 100% 100% 95% 93% 90% ok 10000 20000 -25 to +70°C -35 to +70°C 39 IEC 60947-2 ok ok ok 0,63 to 0.8 to 1 x In -
h250 LSI MCCB HNC HEC 3-4
h400 TM MCCB HND 3-4
h630 LSI MCCB HND HED 3-4
h1000 LSI MCCB HNE HEE 3-4
h1600 LSI MCCB HNF HEF 3-4
250 40-125-250 220-690 50/60 800 8
400 250-400 220-690 50/60 800 8
630 250-630 220-690 50/60 800 8
1000 800-1000 220-690 50/60 800 8
1600 1250-1600 220-690 50/60 800 8
85
100
85
85
100
50 25 7,5 -
70 45 20 -
50 30 20 40
50 30 20
70 30 20
85
100
85
85
85
25 10 7,5 B 40°C 100% 95% 90% 80% 80% ok 10000 30000 -25 to +70°C -35 to +70°C 75 IEC 60947-2 -
70 45 15 -
50 30 15 40 A 50°C 100% 100% 95% 92% 89% ok 4500 15000 -25 to +70°C -35 to +70°C 75 IEC 60947-2 ok ok 0,63 to 0.8 to 1 x In 6-8-10-12 x In
50 30 15
50 30 15
0,4 to 1 x Ir 2,5 to 10 x Ir
-
100
100
100
70 30 20 -
50 45 25 -
70 65 45 -
75
75
B (400A) - A (630A) 40°C 100% 100% 95% 90% 80% ok 4500 15000 -25 to +70°C -35 to +70°C 150 IEC 60947-2 -
85 (800A) 100 (800A) 75 (1000A) 75 (1000A) 50 50 30 30 20 20 B (800A) - A (1000A) 40°C 100% 100% 95% 90% 80% ok 4500 15000 -25 to +70°C -35 to +70°C 150 IEC 60947-2 -
50 45 25 B 40°C 100% 100% 95% 90% 80% ok 4500 15000 -25 to +70°C -35 to +70°C 170 IEC 60947-2 -
50 50 34 -
ok 0,4 2,5 2,5 0,1
ok 0,4 to 1 x In 2,5 to 10 x Ir
-
ok 0,4 2,5 2,5 0,1
0,1 - 0,2s lugs 120 mm2 (cage) 25 ok ok ok ok
lugs 240 mm2 (cage) 30 ok ok ok ok
lugs 30 ok integrated ok
lugs 45 ok integrated ok
lugs 45 ok integrated ok
165 105 140 97 2,5 3,3
260 140 185 97 4,2 5,6
260 140 185 97 4,3 5,7
273/433 210 280 99,5 11 14,8
370/570 210 280 140 27 31
to 1 x Ir to 10 x Ir (400A) to 8 x Ir (630A) - 0,2s
85 (800A) 75 (1000A) 50 30 20 -
to 1 x Ir to 10 x Ir (800A) to 8 x Ir (1000A) - 0,2s
0,1 - 0,2s
5
MCCBs
& accessory selection guide MCCB’s
Terminal connectors
HHA125U Frame
Trip Unit
Pole
3
X160
TM
4
3 x250 4
Frame
x160
x250
6
HNB160U
In (A)
25 kA
40 kA
25 40 63 80 100 125 160 25 40 63 80 100 125 160 160 200 250 160 200 250
HHA025U HHA040U HHA063U HHA080U HHA100U HHA125U HHA160U HHA026U HHA041U HHA064U HHA081U HHA101U HHA126U HHA161U -
HNA025U HNA040U HNA063U HNA080U HNA100U HNA125U HNA160U HNA026U HNA041U HNA064U HNA081U HNA101U HNA126U HNA161U HNB160U HNB200U HNB250U HNB161U HNB201U HNB251U
HYB031H
HYA015H
Terminal connectors Collar Straight
Spreader
Rear
HYA005H
HYA013H
HYA014H
-
HYA006H
HYA013H
HYA015H
-
HYB001H
HYB010H
HYB011H
HYB031H
HYB002H
HYB010H
HYB012H
HYB032H
Shunt Trips - SH
Under Voltage - UV
Motor Operator
Auxilliary Contact (1C/O)
HXA004H
HXA014H
HXB040H
HXA021H
Operating Voltage
Shunt Trips - SH
Under Voltage - UV
Motor Operator
Auxilliary Contact (1C/O) AUX, AX Alarm, AL (1NO + 1NC) (1NO +1NC)
24 VDC 48 VDC
HXA001H HXA002H
HXA011H -
-
100 - 120 VAC 200 - 240 VAC 380 - 450 VAC 24 VDC 48 VDC 100 - 120 VAC 230 - 240 VAC 200 - 240 VAC 380 - 450 VAC
HXA003H HXA004H HXA005H HXA001H HXA002H HXA003H HXA004H HXA005H
HXA013H HXA014H HXA015H HXA011H HXA013H HXA014H HXA015H
HXB040H HXB042H -
HXA024H
HXA021H
HXA024H
HXA021H
HXA024H
Terminal covers
Interlock
Phase Barrier
DIN rail adaptor
Rotary Handle
Padlock
HXB065H
HYA019H
HYA033H
HXA031H
HXA039H
Interlock
Phase Barrier
DIN rail adaptor
Rotary Handle Direct Extended
Padlock
HYA027H
HYB022H
Terminal covers Collar Straight
Spreader
Rear
HYA027H
HYA021H
HYA023H
-
-
HYA019H
HYA033H
HXA030H
HXA031H
HXA039H
HYA028H
HYA022H
HYA024H
-
-
HYA019H
HYA033H
HXA030H
HXA031H
HXA039H
HYB027H
HYB021H
HYB023H
HYB025H
HXB065H
HYB019H
-
HXB030H
HXB031H
HXA039H
HYB028H
HYB022H
HYB024H
HYB026H
HXB065H
HYB019H
-
HXB030H
HXB031H
HXA039H
7
MCCBs
& accessory selection guide MCCB’s
Terminal connectors
HEC250H
Frame
Trip Unit
Pole 3
h250 4 3 h630 LSI
4 3
h1000 4 3 h1600 4
Frame
h250
h630
8
HNE970H
In (A)
50 kA
70 kA
40 125 250 40 125 250 400 630 400 630 800 1000 800 1000 1250 1600 1250 1600
HNC040H HNC125H HNC250H HNC041H HNC126H HNC251H HND400H HND630H HND401H HND631H HNE800H HNE970H HNE801H HNE971H HNF980H HNF990H HNF981H HNF991H
HEC040H HEC125H HEC250H HEC041H HEC126H HEC251H HED400H HED630H HED401H HED631H HEE800H HEE970H HEE801H HEE971H HEF980H HEF990H HEF981H HEF991H
HYD015H
HYD033H
Terminal connectors Collar Straight
Spreader
Rear
HYC003H
HYC010H
HYC011H
HYC031H
HYC004H
HYC010H
HYC012H
HYC032H
HYD003H HYD007H HYD004H HYD008H
HYD010H HYD013H HYD010H HYD013H
HYD011H HYD014H HYD012H HYD015H
-
-
-
-
-
-
HYD031H HYD033H HYD032H HYD034H HYE031H HYE033H HYE032H HYE034H
-
-
-
-
-
-
-
-
Shunt Trips - SH
Under Voltage - UV
Motor Operator
Auxilliary Contact (1C/O)
HXC004H
HXC014H
HXD042H
HXC021H
Operating Voltage
Shunt Trips SH
Under Voltage - UV
Motor Operator
Auxilliary Contact (1C/O) AUX, AX Alarm, AL (1NO + 1NC) (1NO +1NC)
24V DC 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC 24V DC 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC
HXC001H HXC002H HXC003H HXC004H HXC005H HXC001H HXC002H HXC003H HXC004H HXC005H
HXC011H HXC013H HXC014H HXC015H HXC011H HXC013H HXC014H HXC015H
HXC040H HXC042H HXD040H HXD040H HXD042H HXD042H -
HXC024H
HXC021H
HXC024H
HXC021H
HXA024H
Terminal covers
Interlock
Interphase Barrier
Rotary handles
Padlock
HXC065H
HYC019H
HXD030H
HXC039H
Interlock
Interphase Barrier
Rotary handles Direct Extended
Padlock
HYD022H
HYD023H
Terminal covers Collar Straight
Spreader
Rear
HYC027H
HYC021H
-
HYC025H
HXC065H
HYC019H
HXC030H
HXC031H
HXC039H
HYC028H
HYC022H
-
HYC026H
HXC065H
HYC019H
HXC030H
HXC031H
HXC039H
HYD027H
HYD021H
HYD023H
HYD025H
HXD065H
HYD019H
HXD030H
HXD031H
HXD039H
HYD028H
HYD022H
HYD024H
HYD026H
HXD065H
HYD019H
HXD030H
HXD031H
HXD039H
-
HYE021H
-
HYE025H
HXE065H
-
HXE030H
HXE031H
HXD039H
-
HYE022H
-
HYE026H
HXE065H
-
HXE030H
HXE031H
HXD039H
-
-
-
-
-
HXF030H
HXF031H
HXF039H
-
-
-
-
-
HXF030H
HXF031H
HXF039H
Frame
h1000
h1600
Shunt Trips - SH
Under Voltage - UV
Motor Operator
Auxilliary Contact (1C/O)
HXC004H
HXE014H
HXF040H
HXC012H
Operating Voltage
Shunt Trips SH
Under Voltage - UV
Motor Operator
Auxilliary Contact (1C/O) AUX, AX Alarm, AL (1NO + 1NC) (1NO +1NC)
24V DC 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC 24V DC 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC
HXC001H HXC002H HXC003H HXC004H HXC005H HXC001H HXC002H HXC003H HXC004H HXC005H
HXE011H HXE013H HXE014H HXE015H HXE011H HXE013H HXE014H HXE015H
HXE040H HXE040H HXE042H HXE042H HXF040H HXF042H -
HXC024H
HXC021H
HXC024H
HXC021H
HXC024H
9
MCCBs x160 Moulded case circuit breakers x160 - Thermal magnetic trip unit, 2 versions: - Z version: fixed thermal and fixed magnetic - U version: adjustable thermal and fixed magnetic
- 1P, 2P, 3P & 4P - Mechanical test button, sealable settings, integrated padlocking handle Ø4mm.
Connection capacity: - 95mm2 rigid cables - 70mm2 flexible cables - Comply with IEC60947-2.
Technical information: - Visit our website at www.hagerelectro.com.au
*Please check availability with your local Hager sales office at time of order
MCCBs x160 25kA Description
- Breaking capacity Ics: 20kA (400/415V AC) - Fixed thermal 1 x In - Fixed magnetic > 10 x In HHA125U
- Adjustable thermal 0.63 - 0.8 - 1 x In - Fixed magnetic > 10 x In
HHA161U
In
16A 20A 25A 32A 40A 50A 63A 80A 100A 125A 25A 40A 63A 80A 100A 125A 160A
Cat ref.
Cat ref.
Cat ref.
1P
3P
4P*
HHA014Z HHA018Z HHA023Z HHA030Z HHA038Z HHA048Z HHA061Z HHA078Z HHA098Z HHA123Z -
HHA025U HHA040U HHA063U HHA080U HHA100U HHA125U HHA160U
HHA026U HHA041U HHA064U HHA081U HHA101U HHA126U HHA161U
Cat ref.
Cat ref.
MCCBs x160 40kA Description
- Breaking capacity Ics: 20kA (400/415V AC) - Adjustable thermal 0.63 - 0.8 - 1 x In - Fixed magnetic > 10 x In HNA125U
10
In
25A 40A 63A 80A 100A 125A 160A
3P
4P*
HNA025U HNA040U HNA063U HNA080U HNA100U HNA125U HNA160U
HNA026U HNA041U HNA064U HNA081U HNA101U HNA126U HNA161U
MCCBs x160 - accessories Indication contacts - 1 changeover switch (ON/OFF): indicates the position of the MCCB is “open” or “closed”. - 1 changeover alarm contact: indicates MCCB tripping.
Coil connection - Connection capacity: 0.75mm flexible or rigid cables. - Optional connection cables. The cable capacity of the terminals is 0.5 to 1.25mm2. Shunt trip - Remote tripping of MCCBs or trip-free switches. - Operating voltage: 0.7 to 1.1 x Un
Under voltage release - Allows the tripping of MCCBs when voltage level drops between 35 and 70% of Un. - Pick up voltage 0.85 x Un Direct rotary handle - Padlockable - Equipped with front cover and handle - Fixing without any additional screw.
Extended rotary handle - IP 55 - Supplied complete with shaft and handle. Technical information: - Visit our website at www.hagerelectro.com.au
Accessories
HXA021H
Description
Characteristics
Cat ref.
Auxiliary contacts AX AL
1 changeover contact (ON/OFF) 250V AC / 3A 125V DC / 0.4A 1NO + 1NC 1 changeover alarm contact 250V AC / 3A 125V DC / 0.4A 1NO + 1NC 24V DC 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC 24V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC
HXA021H
HXA024H Shunt trips SH
Undervoltage releases UV
HXA004H
HXA014H
HXA024H
HXA001H HXA002H HXA003H HXA004H HXA005H HXA011H HXA013H HXA014H HXA015H
Accessories Description
HXA031H
HYA015H
Direct rotary handle Padlockable Extended rotary handle Padlockable Padlocking device To mount on MCCB for handle locking 3 padlocks Collar terminals Terminals for aluminium conductor Extended connections Straight connections Spreader connections Interphase barriers Terminal covers
Din rail adaptor
Characteristics
Cat ref.
Cat ref.
3P
4P
Max Ø 6mm
HXA030H
HXA030H
Max Ø 8mm 200mm Max Ø 8mm
HXA031H
HXA031H
HXA039H
HXA039H
Set of 3 or 4
HYA005H
HYA006H
Set of 4 Set of 3 or 4 Set of x 2 Height: 50mm For extended straight connections For extended spreader connections For collar terminal
HYA013H HYA014H HYA019H
HYA013H HYA015H HYA019H
HYA021H HYA023H
HYA022H HYA024H
HYA027H HYA033H
HYA028H HYA033H
HYA021H
11
MCCBs x250 Moulded case circuit breakers x250 - Adjustable thermal and magnetic trip unit - 3P and 4P - Mechanical test button
- Lockable settings - Integrated padlocking handle Ø 4mm - Complies with IEC60947-2. Connection: - Terminal area width 25mm
Connection capacity: - 185mm2 rigid cables - Collar terminals optional Technical information: - Visit our website at www.hagerelectro.com.au
*Please check availability with your local Hager sales office at time of order
MCCBs x250 40kA Description
HNB160U
12
Breaking capacity Icu: 40 kA (400/415V AC) Ics: 20 kA Adjustable thermal 0.63 - 0.8 - 1x In Adjustable magnetic 6 - 8 - 10 - 13 x In (160/200A) 5 - 7 - 9 - 11 x In (250A) 4P neutral setting: 0 or 100%
In
160A 200A 250A
Cat ref.
Cat ref.
3P
4P*
HNB160U HNB200U HNB250U
HNB161U HNB201U HNB251U
MCCBs x250 - accessories Indication contacts - 1 changeover switch (ON/OFF): indicates the position of the MCCB is “open” or “closed”. - 1 changeover alarm contact: indicates MCCB tripping.
Coil connection - Connection capacity: 0.75mm2 flexible or rigid cables - Optional connection cables. The cable capacity of the terminals is 0.5 to 1.25mm2. Shunt trip - Remote tripping of MCCBs or trip-free switches. Operating voltage: 0.7 to 1.1 x Un.
Under voltage release - Allows the tripping of MCCBs when voltage level drops between 35 and 70% of Un. - Pick up voltage 0.85 x Un. Direct rotary handle - Padlockable - Equipped with front cover and handle - Fixing without any additional screw.
Extended rotary handle - IP55 - Supplied complete with shaft and handle. Technical information: - Visit our website at www.hagerelectro.com.au
Accessories
HXA021H
Description
Characteristics
Cat ref.
Auxiliary contacts AX AL
1 changeover contact 250V AC / 3A 125V DC / 0.4A 1NO + 1NC 1 changeover alarm contact 250V AC / 3A 125V DC / 0.4A 1NO + 1NC 24V DC 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC 24V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC Max Ø 6mm
HXA021H
HXA024H Shunt trips SH
Undervoltage releases UV HXA004H
HXA014H Direct rotary handles Padlockable Extended rotary handles Padlockable Padlocking device To mount on MCCBs for handle locking 3 padlocks Motor operators
HXB040H
HXA024H
HXA001H HXA002H HXA003H HXA004H HXA005H HXA011H HXA013H HXA014H HXA015H HXB030H HXB031H
Max Ø 8mm 200mm Max Ø 8mm
HXA039H
24V DC 230 - 240V AC
HXB040H HXB042H
Accessories Cat ref.
HYB022H
HYB024H
Characteristics
3P
4P
Interlocking Collar terminals Aluminium / copper conductors 150mm2 rigid cables 185mm2 flexible cables Extended connections For straight connections
Wire type Set of 4 pieces
HXB065H HYB001H
HXB065H HYB002H
Set of 4 pieces Set of 4 pieces Set of 3 pieces Set of 3 Height: 97mm For extended straight connections For extended spreader connections For rear connections For collar terminals
HYB010H HYB011H HYB031H HYB019H
HYB010H HYB012H HYB032H HYB019H
HYB021H HYB023H
HYB022H HYB024H
HYB025H HYB027H
HYB026H HYB028H
For spreader connections Rear connections Interphase barriers Terminal covers
HYB031H
Cat ref.
Description
13
MCCBs h250 Moulded case circuit breakers h250 - 3P & 4P - Mechanical test button, sealable settings. - Comply with IEC 60947-2. Connection: Terminal area width 25 mm
Electronic trip unit LSI: - Long delay (thermal equivalent) adjustable: Ir = 0.4 to 1 x In - Short delay (magnetic equivalent) adjustable: 2.5 to 10 x Ir - Time delay: 0.1 - 0.2s
Technical information: - Visit our website at www.hagerelectro.com.au
*Please check availability with your local Hager sales office at time of order
MCCBs h250 50kA LSI Description
- Breaking capacity Icu: 50 kA (400/415V AC) Ics: 25 kA HNC250H
- Adjustable thermal Ir = 0.4 to 1 x In
Characteristics
Cat ref.
Cat ref.
3P
4P*
40A 125A 250A
HNC040H HNC125H HNC250H
HNC041H HNC126H HNC251H
Characteristics
Cat ref.
Cat ref.
- Adjustable magnetic 2.5 to 10 x Ir
MCCBs h250 70kA LSI Description
HEC250H
14
- Breaking capacity Icu: 70 kA (400/415V AC) Ics: 70 kA - Adjustable thermal Ir = 0.4 to 1 x In - Adjustable magnetic 2.5 to 10 x Ir
40A 125A 250A
3P
4P*
HEC040H HEC125H HEC250H
HEC041H HEC126H HEC251H
MCCBs h250 - accessories Indication contacts - 1 changeover switch (ON/OFF): indicates the position of the MCCB is “open” or “closed”. - 1 changeover alarm contact: indicates MCCB tripping.
Coil connection - Connection capacity: 0.75mm2 flexible or rigid cables - Optional connection cables. The cable capacity of the terminals is 0.5 to 1.25mm2. Shunt trip - Remote tripping of MCCBs or trip-free switches. Operating voltage: 0.7 to 1.1 x Un.
Under voltage release - Allows the tripping of MCCBs when voltage level drops between 35 and 70% of Un. - Pick up voltage 0.85 x Un. Direct rotary handle - Padlockable - Equipped with front cover and handle - Fixing without any additional screw.
Extended rotary handle - IP55 - Supplied complete with shaft and handle. Technical information: - Visit our website at www.hagerelectro.com.au
Accessories
HXC021H
Description
Characteristics
Cat ref.
Auxiliary contacts AX AL
1 changeover contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 1 changeover alarm contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 24V DC
HXC021H
48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC 24V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC Ø 5 - 8mm2 max
HXC002H HXC003H HXC004H HXC005H HXC011H HXC013H HXC014H HXC015H HXC030H
Ø 5 - 8mm2 max 320mm Max Ø 5mm
HXC031H
24V DC 230-240V AC
HXC040H HXC042H HXC065H
HXC024H Shunt trips SH
Undervoltage releases UV HXC004H
HXC014H Direct rotary handles Padlockable Extended rotary handles Padlockable Padlocking device To mount on MCCBs for handle locking 3 padlocks Motor operators
HXC039H
HXC024H
HXC001H
HXC039H
Interlocking Wire type
Accessories Description
HYC011H
Collar terminals Extended connections Rear connections Interphase barriers Terminal covers
HYC031H
Characteristics
Copper Straight connections Spreader connections
Cat ref. 3P
4P
HYC003H HYC010H HYC011H HYC031H HYC019H
HYC004H HYC010H HYC012H HYC032H HYC019H
Set of 3 Height: 97mm For extended straight connections HYC021H (LSI only) HYC025H For rear connections HYC027H For collar terminals
HYC022H HYC026H HYC028H
15
MCCBs h630 Moulded case circuit breakers h630 - 3P & 4P - Adjustable neutral 0 - 50% - 100% - Mechanical test button, lockable settings - Comply with IEC 60947-2. Connection: - Directly on copper cable terminal, with end lug max. width: 30mm
Electronic trip unit LSI: - Long delay (thermal equivalent) adjustable: Ir = 0.4 to 1 x In - Short delay (magnetic equivalent) adjustable: 2.5 to 10 x Ir (400A) 2.5 to 8 x Ir (630A) - Time delay: 0.1 - 0.2 s
Technical information: - Visit our website at www.hagerelectro.com.au
*Please check availability with your local Hager sales office at time of order
MCCBs h630 50kA LSI Description
HND630H
- Breaking capacity Icu: 50 kA (400/415V AC) Ics: 50 kA - Adjustable thermal Ir = 0.4 to 1 x In - Adjustable magnetic 2.5 to 10 x Ir (400A) 2.5 to 8 x Ir (630A) - Time delay: 0.1 - 0.2s
In
Cat ref.
Cat ref.
3P
4P*
400A 630A
HND400H HND630H
HND401H HND631H
In
Cat ref.
Cat ref.
MCCBs h630 70kA LSI Description
HED630H
16
- Breaking capacity Icu: 70 kA (400/415V AC) Ics: 50 kA - Adjustable thermal Ir = 0.4 to 1 x In - Adjustable magnetic 2.5 to 10 x Ir (400A) 2.5 to 8 x Ir (630A) - Time delay: 0.1 - 0.2s
400A 630A
3P
4P*
HED400H HED630H
HED401H HED631H
MCCBs h630 - accessories Indication contacts - 1 changeover switch (ON/OFF): indicates the position of the MCCB is “open” or “closed”. - 1 changeover alarm contact: indicates MCCB tripping. Coil connection - Connection capacity: 0.75mm2 flexible or rigid cables - Optional connection cables. The cable capacity of the terminals is 0.5 to 1.25mm2.
Shunt trip - Remote tripping of MCCBs. Operating voltage: 0.7 to 1.1 x Un. Under voltage release - Allows the tripping of MCCBs when voltage level drops between 35 and 70% of Un. - Pick up voltage 0.85 x Un.
Direct rotary handle - Padlockable - Equipped with front cover and handle - Fixing without any additional screw.
Technical information: - Visit our website at www.hagerelectro.com.au
Extended rotary handle - IP55 - Supplied complete with shaft and handle.
Accessories
HXC021H
Description
Characteristics
Cat ref.
Auxiliary contacts AX AL
1 changeover contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 1 changeover alarm contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 24V DC 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC 24V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC Max Ø 6 mm
HXC021H
HXC024H Shunt trips SH
Undervoltage releases UV
HXC004H
HXC014H Direct rotary handles Padlockable Extended rotary handles Padlockable Padlocking device To mount on MCCBs for handle locking 3 padlocks
Max Ø 8mm 320mm Max Ø 8mm
HXC024H
HXC001H HXC002H HXC003H HXC004H HXC005H HXC011H HXC013H HXC014H HXC015H HXD030H HXD031H HXD039H
HXD030H
HXD039H
17
MCCBs h630 - accessories Accessories Cat ref.
HXD042H
HYD003H
Description
Characteristics
Motor operators
24-48V DC 100-240V AC
Interlocking Wire type Collar terminals Terminals for copper conductors 1 x 35 - 240mm2 Terminals for multiple aluminium/copper conductors 2 x 35 - 240mm2 Extended connections For straight connections For spreader connections
HYD015H
HYD022H
HYD033H
18
Terminal covers For extended straight connections For extended spreader connections For rear connections For collar terminals
Cat ref.
3P
4P
HXD040H HXD042H HXD065H
HXD040H HXD042H HXD065H
Set of 3 or 4
160 - 400A
HYD003H
HYD004H
Set of 3 or 4
400 - 630A
HYD007H
HYD008H
Set of 4 pieces
400A 630A 400A 630A 400A 630A
HYD010H HYD013H HYD011H HYD014H HYD031H HYD033H HYD019H
HYD010H HYD013H HYD012H HYD015H HYD032H HYD034H HYD019H
HYD021H HYD023H
HYD022H HYD024H
HYD025H HYD027H
HYD026H HYD028H
Set of 4 pieces
Rear connections Interphase barriers
In
Set of 3 Height: 97mm
MCCBs h1000 Moulded case circuit breakers h1000 - 3P & 4P - Adjustable neutral 0 - 50% - 100% - Mechanical test button, lockable settings. Connection: - Direct on copper terminal, with end lug max. width: 50mm - Comply with IEC60947-2.
Electronic trip unit LSI: - Long delay (thermal equivalent) adjustable: Ir= 0,4 to 1 x In - Short delay (magnetic equivalent) adjustable: 2,5 to 10 x Ir (630-800A) 2.5 to 8 x Ir (1000A) - Time delay: 0.1-0.2s
Technical information: - Visit our website at www.hagerelectro.com.au
*Please check availability with your local Hager sales office at time of order
MCCBs h1000 50kA LSI Description
HNE970H
- Breaking capacity Icu: 50 kA (400/415V AC) Ics: 50 kA - Adjustable thermal Ir = 0,4 to 1 x In - Adjustable magnetic 2,5 to 10 x Ir (800A) 2,5 to 8 x Ir (1000A) - Time delay: 0.1-0.2s - Neutral setting from 0-50 to 100%
In
800A 1000A
Cat ref.
Cat ref.
3P
4P*
HNE800H HNE970H
HNE801H HNE971H
MCCBs h1000 70kA LSI Description
HEE801H
- Breaking capacity Icu: 70 kA (400/415V AC) Ics: 50 kA - Adjustable thermal Ir = 0,4 to 1 x In - Adjustable magnetic 2,5 to 10 x Ir (800A) 2,5 to 8 x Ir (1000A) - Time delay: 0,1-0,2s - Neutral setting from 0-50 to 100%
In
800A 1000A
Cat ref.
Cat ref.
3P
4P*
HEE800H HEE970H
HEE801H HEE971H
19
MCCBs h1000 - accessories Indication contacts - 1 changeover switch (ON/OFF): indicates the position of the MCCB is “open” or “closed”. - 1 changeover alarm contact: indicates MCCB tripping. Coil connection - Connection capacity: 0.75mm2 flexible or rigid cables - Optional connection cables. The cable capacity of the terminals is 0.5 to 1.25mm2.
Shunt trip - Remote tripping of MCCBs. Operating voltage: 0.7 to 1.1 x Un. Under voltage release - Allows the tripping of MCCBs when voltage level drops between 35 and 70% of Un. - Pick up voltage 0.85 x Un.
Direct rotary handle - Padlockable - Equipped with front cover and handle - Fixing without any additional screw.
Technical information: - Visit our website at www.hagerelectro.com.au
Extended rotary handle - IP55 - Supplied complete with shaft and handle.
Accessories
HXC021H
Description
Characteristics
Cat ref.
Auxiliary contacts AX AL
1 changeover contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 1 changeover alarm contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 24V DC
HXC021H
HXC024H Shunt trips SH
Undervoltage releases UV HXC004H
HXE014H Direct rotary handle Padlockable Extended rotary handles Padlockable Padlocking device To mount on MCCB for handle locking 3 padlocks Motor operators
HXD039H
48V DC 100 - 120V 200 - 240V 380 - 450V 24V DC 100 - 120V 200 - 240V 380 - 450V
HXC024H
HXC001H HXC002H HXC003H HXC004H HXC005H HXE011H HXE013H HXE014H HXE015H HXE030H
AC AC AC AC AC AC
HXE031H
Max Ø 8mm 320mm Max Ø 8 mm
HXD039H
HXE040H HXE042H HXE065H
24 - 48V DC 100 - 240V AC
Interlocking Wire type
Accessories Description
HYE031H
20
Terminal covers For extended connections For rear connections Rear connections
In
800A 1000A
Cat ref.
Cat ref.
3P
4P*
HYE021H HYE025H HYE031H HYE033H
HYE022H HYE026H HYE032H HYE034H
MCCBs h1600 Moulded case circuit breakers h1600 - 3 pole - 3 trip units 4 pole - 4 trip units - Adjustable neutral 0 - 50% - 100% - Mechanical test button, lockable settings. - Comply with IEC60947-2.
- Short delay (magnetic equivalent) adjustable: 2.5 to 10 x Ir - Time delay: 0.1-0.2
Technical information: - Visit our website at www.hagerelectro.com.au
Connection: - Directly on copper cable terminal, with end lug max. width: 60mm
Electronic trip unit LSI: - Long delay (thermal equivalent) adjustable: Ir = 0.4 to 1 x In *Please check availability with your local Hager sales office at time of order
MCCBs h1600 50kA LSI Description
HNF990H
- Breaking capacity Icu: 50 kA (400/415V AC) Ics: 50 kA - Adjustable thermal Ir = 0.4 to 1 x In - Adjustable magnetic 2.5 to 10 x Ir - Time delay: 0.1-0.2s - Neutral setting 0, 50, 100%
In
1250A 1600A
Cat ref.
Cat ref.
3P
4P*
HNF980H HNF990H
HNF981H HNF991H
MCCBs h1600 70kA LSI Description
HEF980H
In
1250A - Breaking capacity Icu: 70 kA (400/415V AC) 1600A Ics: 50 kA - Adjustable thermal Ir = 0.4 to 1 x In - Adjustable magnetic 2.5 to 10 x Ir - Time delay: 0.1-0.2s - Neutral setting from 0, 50, 100%
Cat ref.
Cat ref.
3P
4P*
HEF980H HEF990H
HEF981H HEF991H
21
MCCBs h1600 - accessories Indication contacts - 1 changeover switch (ON/OFF): indicates the position of the MCCB is “open” or “closed”. - 1 changeover alarm contact: indicates MCCB tripping. Coil connection - Connection capacity: 0.75mm2 flexible or rigid cables - Optional connection cables. The cable capacity of the terminals is 0.5 to 1.25mm2.
Shunt trip - Remote tripping of MCCBs. Operating voltage: 0.7 to 1.1 x Un. Under voltage release - Allows the tripping of MCCBs when voltage level drops between 35 and 70% of Un. - Pick up voltage 0.85 x Un.
Direct rotary handle - Padlockable - Equipped with front cover and handle - Fixing without any additional screw.
Technical information: - Visit our website at www.hagerelectro.com.au
Extended rotary handle - IP55 - Supplied complete with shaft and handle. Rear connection included
Accessories
HXC021H
Description
Characteristics
Cat ref.
Auxiliary contacts AX AL
1 changeover contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 1 changeover alarm contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 24V DC
HXC021H
HXF001H
48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC 24V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC Max Ø 8mm
HXF002H HXF003H HXF004H HXF005H HXE011H HXE013H HXE014H HXE015H HXF030H
Max Ø 8mm 320mm Max Ø 8mm
HXF031H HXF039H
24V DC 200 - 230V AC
HXF040H HXF042H
HXC024H Shunt trips SH
Undervoltage releases UV HXF004H
HXE014H Direct rotary handles Padlockable Extended rotary handles Padlockable Padlocking device To mount on MCCBs for handle locking 3 padlocks Motor operators
HXF040H
22
HXC024H
Your complete solution for Commercial / Large Multi Residential
Take advantage of Hager project solutions Introducing the quadro M modular switchboard system which can be tailored to meet any design specification from a simple metering panel to a main switchboard designed for up to 630A. Combine this with Hager’s unimes modular switchboards which enable the use of functional equipment with rated current up to 1600A and you have a complete solution for any residential, commercial and multi-residential project. As part of the solution, our projects team can offer end to end project management from quotation and design services to full assembly of packaged products in switchboards, panelboards and group metering boards, delivery to site and after sales service.
www.hagerelectro.com.au
Hager Electro Pty Ltd 1/170 Power Street Glendenning NSW 2761 www.hagerelectro.com.au
Nationwide sales Ph 1300 850 253 Fx 1300 424 372 Email:
[email protected]
State offices in: New South Wales South East Queensland North Queensland Victoria South Australia Western Australia
Distributors in: Tasmania Northern Territory
DISCLAIMER: Whilst every effort has been made to ensure the reliability of the information is correct at time of publication, Hager cannot guarantee the accuracy of all of the information contained herein. Changes/updates brought to the attention of Hager, once verified, will be corrected in future editions.