High frequency transformer model for calculations of
Recommend Documents
etc. compared with traditional line frequency transformer. The 7.2kV AC to ... switching frequency of dual active bridge (DAB) DC-DC ... Fig.1: The topology of the 7.2kV to 120V/240V 20kVA Gen-I Solid ... TABLE II: SEVERAL HIGH FREQUENCY MAGNETIC COR
Slovenija, Vetrinjska 2, Maribor 2000, Slovenija (e-mail: [email protected]). Abstract â An algorithm for the calculations of low frequency transformer transients ...
AbstractâA high frequency transformer is a critical compo- nent in a dual active bridge converter (DAB) used in a power electronics-based solid state ...
The circuit model for a specific transformer winding was implemented using ... 2.2
GENERAL CAUSES OF WINDING DEFORMATION. 12. Natural Ageing. 12.
and the low voltage residential micro-grid. Three cascaded. 6.7kVA high-voltage high-frequency transformers operating at 3kHz are employed to convert voltage ...
In contrast, little attention has been given to the area of the design of the
magnetic ... exact transformer equivalent circuit to cover the wide frequency
range.
NMVFT and its control system are developed using MATLAB. The out power thus generated in v/f ... speed drive i.e. dc shunt motor via mechanical coupler and ...
New Model Variable Frequency Transformer. (NMVFT) A Technology for V/f Control of. Induction Motors. Farhad Ilahi Bakhsh, Mohammad Irshad, and Shirazul ...
Nov 30, 2012 - e development of the smart grids leads to new challenges on the power electronics equipment and power transformers. e use of power ...
Nov 30, 2012 - ing the final equivalent electric circuit using the well- established .... (v) Modeling of the autotransformer is straightforward. Only an external ...
CLAUDIA CECI. Dipartimento di ...... [14] I. J. Gihman and A. V. Skorohod, Stochastic Differential Equations, Springer-Verlag (1972). [15] J. Jacod, Calcul ...
12220 World Trade Drive. San Diego, CA 92128. U.S.A.. Tel: 858 674 8100. Fax: 858 674 8262. Pulse Europe. Zeppelinstrass
3, MARCH 2015. 8500204. Integrated High-Frequency Coaxial Transformer. Design Platform Using Artificial Neural Network. Optimization and FEM Simulation.
snubber network, and the structure of the Deadbeat controller. frequency link inverter using the center-tapped transformer. Section III shows the hardware ...
secondary x 100 ) / (%Z transformer. ) Source and Transformer Impedance. The
actual short circuit current available at a transformer's secondary terminals is not
...
Monitoring the health of power transformer is important for the reliability of ... 132/33kV, 90MVA power transformer based on FRA data using signal processing.
are calculated for different cable lengths, and the cumulative prob- ability of ... application of the VCBs to protect power distribution circuits has increased, and it ...
Feb 23, 2012 - 6 Transformers in the Nodal Admittance Matrix. 17. 7 e Nodal Admittance Matrix during TCUL. 18. 8 Integrating TCUL into FDLF. 19. List of ...
Abstract: Modeling financial time series at different time scales is still an open challenge. The choice of a suitable indicator quantifying the distance between the ...
1), there is a certain general similarity in the change of the ratio of the most refractory components (CaO and Al2O3) in the residual melts during evaporation.
The model is based on the classical 60-Hz equivalent circuit, extended .... The
resulting model is ac- ..... [21] Edith Clarke, Circuit Analysis of A-C Power
Systems.
Mar 3, 1986 ... Publication entitled “J and P Switchgear Book”, Sev enth Edition, by R. T. Lythall.
Primary Examiner-Peter S. Wong. Assistant Examiner-Anita M.
for High Frequency Financial Count Dataâ ... within intra-day time series of transaction frequency data due to macro- ... trading intensity implies no news.
Abstract. A vector integer-valued moving average (VINMA) model is introduced. The VINMA model allows for both positive and negative correlations between ...
High frequency transformer model for calculations of
transient simulations (EMTP), therefore it is particularly important to model properly apparatuses. Since transformer ... block in EMTP-RV. The developed model ...
21, rue d’Artois, F-75008 PARIS http : //www.cigre.org
International Colloquium on Lightning and Power systems
INSA LYON France
High frequency transformer model for calculations of transferred overvoltages B. JURISIC*, A. XEMARD EDF R&D, France
I. UGLESIC University of Zagreb, Croatia
F. PALADIAN University Blaise Pascal, France
SUMMARY Equipment in the power grid have to be protected against overvoltages. Lightning or some switching operations can cause high frequency overvoltages. The choice of the rules adapted at design stage regarding insulation coordination is usually based on Electromagnetic transient simulations (EMTP), therefore it is particularly important to model properly apparatuses. Since transformer behavior at high frequencies is mainly dependent on its capacitances, classical, low frequency transformer models cannot be used for high frequency transient simulations. Therefore, some other models have to be developed. Nevertheless, nowadays high frequency models of the transformer which are compatible with the EMTPlike tools are neither standardized nor easy to use. In this paper an overview of a complete procedure for establishing a state of the art transformer model for high frequency based on terminal measurement is given. Procedure includes measurements of the scattering parameters of the transformer, calculation of transformer admittance matrix, rational approximation and usage of the state space equation block in EMTP-RV. The developed model represents a transformer as a black box and is suitable for calculation of transferred high frequency overvoltages through a transformer. A case study is included in the paper. KEYWORDS Transformer - “Black Box” Model - Transient Simulation - Rational Approximation - State Space Equation - Scattering Parameter - Electromagnetic Transient Program (EMTP)