HUBER+SUHNER DATA SHEET - Intelek

20 downloads 228 Views 66KB Size Report
6 Feb 2008 ... according to IEC 60793-2-50 B1.1 and/or B1.3 and ITU-T G.652D. Optional: NZDSF, according to IEC 60793-2-50 B4 and ITU-T G.655.
HUBER+SUHNER DATA SHEET

FIBER OPTIC CABLE: UP TO 60-.../BWSN(ZNG)Y-...100

Rev: E.00

Description

Multi-fiber Loose Tube Cable • • • • •

Metal free indoor and outdoor cable Rodent-protected, glass-armoured High chemical resistance against acids/alkalies Halogen free and non-corrosive fire gases Longitudinal and transversal watertight cable

Comment

- Diameter optimised cable design - Less required space - Less weight

Available Types

Fiber count: 24 up to 60 Fibers

Type of Fiber Standard: Optional: Standard: Standard:

Standard Colours Fiber: Tube: Jacket (outer):

E9, NZDSF, G50, G62,

according to IEC 60793-2-50 B1.1 and/or B1.3 and ITU-T G.652D according to IEC 60793-2-50 B4 and ITU-T G.655 according to IEC 60793-2-10 A1.1a and ITU-T G.651 according to IEC 60793-2-10 A1.1b

According to colour code 1st red, 2nd green, further white, dummies black Black with two orange stripes

Technical Data Construction

Pos. Description / Material

1 2 3 4 5 6 7 8

1 Strength member 60 Optical fiber 5 Multi-fiber loose tube up to 12 fibers Reinforcement / glass-roving 2 Ripcords Jacket with two orange stripes / LD-PE

Size

1.6 mm 250 µm 2.2 mm 10 mm

Options / Notice Fiber type, colour Colour, jelly-filled Swellable Swellable Colour, inscription

Mechanical data Characteristics Weight Tensile strength

Minimal bending radius Crush resistance Impact resistance Repeated bending

Document: DOC-0000267529 F

Conditions

Tested acc. to

during installation (r ≥ 150 mm) in Service (r ≥ 100 mm) During installation, 6 turns In service, 6 turns During installation In service Wp = 2.21 J radius = 50 mm / weight = 1 kg

IEC 60794-1-2 E1

Issued: 02.06.2008 14:31:56

IEC 60794-1-2 E11 IEC 60794-1-2 E3 IEC 60794-1-2 E4 IEC 60794-1-2 E6

Uncontrolled Copy

Values

88 6000 3000 150 100 800 300 50 1000

kg/km N N mm mm N/cm N/cm impacts cycles

Page 1/2

HUBER+SUHNER DATA SHEET

FIBER OPTIC CABLE: UP TO 60-.../BWSN(ZNG)Y-...100

Rev: E.00

Environmental Data Characteristics

Temperature range Fire load

Conditions

Tested acc. to

during installation in service in storage

IEC 60794-1-2 F1

2002/95/EC (RoHS) Water penetration h=1m, 24h, p