IEC and ISO Test Methods

24 downloads 469 Views 25KB Size Report
Feb 7, 2012 ... ISO 75-2. C. -. -. ISO Tensile Strength. ISO 527-2. MPa. -. -. ISO Flexural Strength. ISO 178. MPa. -. -. ISO Tensile Impact. ISO 8256. kJ/m2.
UL iQ™ for Plastics

Page 1 of 1

E333734

Component - Plastics

INVISTA S A R L 4123 E 37TH ST N, WICHITA KS 67220

NPD-002 Polyamide 66 (PA66), heat stabilized, furnished as pellets

Color NC, BK ALL

Min Thk (mm) 0.40 0.71 1.5 3.0

Flame Class V-2 V-2 V-2 V-2

HWI -

HAI -

RTI Elec 65 140 140 140

RTI Imp 65 105 110 110

Comparative Tracking Index (CTI): -

Inclined Plane Tracking (IPT): -

Dielectric Strength (kV/mm): -

Volume Resistivity (10x ohm-cm) : -

High-Voltage Arc Tracking Rate (HVTR): Dimensional Stability (%): -

RTI Str 65 120 125 125

High Volt, Low Current Arc Resis (D495): -

ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 smallscale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end -product devices and appliances, where the acceptability of the combination is determined by UL.

Report Date: 2010-04-05 Last Revised: 2012-02-07

© 2012 UL LLC

IEC and ISO Test Methods

C C Volts (Max) C C MPa MPa

Thickness Tested (mm) 0.40 0.71 1.5 3.0 -

Value V-2 (NC, BK) V-2 (NC, BK) V-2 (ALL) V-2 (ALL) -

kJ/m2

-

-

2

-

-

2

-

-

Test Name Flammability

Test Method IEC 60695-11-10

Units Class (color)

Glow-Wire Flammability (GWFI) Glow-Wire Ignition (GWIT) IEC Comparative Tracking Index IEC Ball Pressure ISO Heat Deflection (1.80 MPa) ISO Tensile Strength ISO Flexural Strength

IEC 60695-2-12 IEC 60695-2-13 IEC 60112 IEC 60695-10-2 ISO 75-2 ISO 527-2 ISO 178

ISO Tensile Impact

ISO 8256

ISO Izod Impact

ISO 180

ISO Charpy Impact

ISO 179-2

kJ/m kJ/m

© 2012 UL LLC

http://iq.ul.com/iq/newiq/list.aspx?ulid=100640049

3/14/2012