iHEAT BOILERS CAN BE INSTALLED IN A WIDE RANGE OF DOMESTIC ...
Halstead Boilers is continuously improving its products and may therefore
change ...
Artwork v2
9/9/08
14:17
Page 1
i H E AT F LU E K I TS
iHeat Combi
iHEAT BOILERS CAN BE INSTALLED IN A WIDE RANGE OF DOMESTIC APPLICATIONS. IN ADDITION TO THE COMMON HORIZONTAL AND VERTICAL FLUE SYSTEMS FAMILIAR TO MOST, WE HAVE ALSO DEVELOPED A RANGE OF FLUE SYSTEMS DESIGNED TO OVERCOME THE POSSIBLE NUISANCE CAUSED BY FLUE PLUMING. THESE KITS ARE DETAILED BELOW. KIT
A
PLUS
OVERVIEW
KIT
SEDBUK ‘B’ RATED
B
SELF DIAGNOSTIC
2 YEAR WARRANTY
FROST PROTECTION
BUILT-IN CLOCK
KIT
C
FLEXIBLE FLUEING
NO VENTILATION REQUIRED
100% PRE–SET & TESTED EASY INSTALLATION
Sedbuk B rated Factory set for simple commissioning. Only minimal adjustments are required after installation and automatic modulation eliminates the need to range rate the boiler. Anti-cycling control prevents energy wasteful on/off cycling and reduces wear and tear. Built-in frost thermostat protects the appliance from damage during periods of cold weather. Versatile flueing options enable the boiler to be sited almost anywhere in the home. Cleanly styled, Italian designed casing blends easily into any setting. Plated heat exchanger reduces the risk of scaling and comes with 5-year anti-scale warranty.
INSTALLER FEATURES Gas pressure set by gas valve, therefore no flue Gas Analyser required. Designed for easy installation. Standard pipework layout enables trouble-free replacement of older models.
A
Warranty
SEDBUK
A
SEDBUK 5 YEAR
B
Heat Exchanger Warranty 2 Years on Other Parts subject to conditions
Installation time saving features: Built-in condense trap with safety device and push-fit connection, factory fitted fly-lead and no ventilation is required.
2 YEAR Warranty
25
Call Us
10
LIFE YEAR TIME CombustionCylinder analysis test point for easy servicing and Cylinder
TRAINING for condensing, combiBuilt-in mechanical clock. YEAR and other boilers 0844 371 1111maintenance. Guarantee
KIT
TELESCOPIC HORIZONTAL FLUE KIT 956120 Standard flue length 430-615mm Maximum flue length 5m
KIT
RAISED EXTERNAL FLUE OUTLET 956084 Standard flue length 1100mm Maximum horizontal 5m and 1m vertical Maximum vertical 8.5m and 1m horizontal
KIT
C KIT
B KIT
F
iHeat
KIT
A
PLUS
SPLIT PIPE VERTICAL FLUE OUTLET 956080 Standard flue length 2.7m Maximum flue length 30m
F
KIT
D
KIT
CHIMNEY FLUE LINER 956082 Flexi tube available in lengths of: 10m 956110 20m 956111 30m 956112 Maximum flue length 30m
E
STANDARD VERTICAL FLUE 956081 Standard flue length 600mm Maximum flue length 12m
B
EXTERNAL VERTICAL FLUE 956085 Standard flue length 2.3m Maximum flue length 6.5m
D
iHeat Combi band B
Low-NOx - Class-5 performance.
ANTI-PLUME FLUE KIT OPTIONS
KIT
B
CONTEMPORARY DESIGN BOILERS
For flueing accessories, see price list or product and flue guide. PLUME DIVERTER KIT 956103 For use with Kit A Plus only.
i H E AT TE C H N I C A L S P E C I F I C AT I O N S
USER FEATURES
LIFE TIME
E
KIT
BAND B – 24C & 29C
DBUK
KIT
Guarantee
Can be converted to LPG with LPG kit.
Warranty
SEDBUK
A
Central heating Heat input (kW) Minimum heat output@ 80/60 °C (kW) Maximum heat output@ 80/60 °C (kW) Maximum heat output@ 50/30 °C (kW) Minimum heat output@ 50/30 °C (kW) Minimum working pressure (bar) Maximum working pressure (bar) Minimum flow rate (litres/Min) Domestic hot water Maximum output (kW) Minimum output (kW) Flow rate at 35 °C rise (l/min) Maximum inlet pressure (bar) Minimum inlet working pressure (bar) Minimum flow rate (l/min) Expansion vessel Capacity (litres) Maximum system volume (litres) Pre-charge pressure (bar) Dimensions (mm) Height Width Depth Dry weight (Kg) Clearances (mm) Sides Top - Above flue elbow Bottom Front Connections (mm) Flow & return Hot & cold water connections Gas Pressure relief safety valve Condense Electrical Voltage Power consumption (Watts) Internal fuse (Amps) External fuse (Amps) Flue details (concentric) Maximum horizontal flue length (60/100mm) - Metres Maximum vertical flue length Maximum horizontal flue length (80/125mm) - Metres SEDBUK Maximum vertical flue length (80/125mm) - Metres Flue details (twin pipe 80mm + 80mm) Maximum horizontal flue length - metres Maximum vertical flue length - metres Efficiency SEDBUK % and Band Combustion Emissions NO x Class CO2 @ Maximum output
B
iHeat Combi band A
iHeat System
iHeat OV
24C
29C
25C
30C
35C
25S
20 OV
25 14.25 24.35 25.9 14.85 0.5 3 5.9
29 14.28 28.3 29.93 14.75 0.5 3 5.9
20 5.9 19.6 21 6.4 0.5 2.7 5.9
25 6.9 24.45 26.3 7.47 0.5 2.7 5.9
30 6.84 29.31 31.83 7.41 0.5 2.7 5.9
25 6 24.53 26.3 6.37 0.5 2.7 5.9
20 5 19.68 21.16 5.3 0.1 3 14.2
25 9.5 10.2 6 0.15 2
29 9.9 11.9 6 0.15 2
25 9.5 10.3 6 0.15 2
30 9.9 12.3 6 0.15 2
34.6 9.9 14.2 6 0.15 2
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
8 76 1
10 76 1
8 76 1
10 91 1
10 91 1
8 76 1
N/A N/A N/A
780 400 332 40
780 450 332 44
780 400 358 40
780 450 358 43
780 450 358 45
780 400 358 37
740 400 340 28
12 25 150 600
12 25 150 600
12 25 150 600
12 25 150 600
12 25 150 600
12 25 150 600
12 25 150 600
22 15 15 15 21
22 15 15 15 21
22 15 15 15 21
22 15 15 15 21
22 15 15 15 21
28 N/A 15 15 21
22 N/A 15 N/A 21
230V/~50Hz 153 2 3
230V/~50Hz 153 2 3
230V/~50Hz 230V/~50Hz 230V/~50Hz 150 150 150 3.15A T for PCB. 3.15A F for connections block 3 3 3
230V/~50Hz 150
230V/~50Hz 75
3
3
4.5
4
7.8
7.8
7.8
7.8
7.8
5.5 11
5 9
8.8 20
8.8 20
8.8 20
8.8 20
8.8 20
12
10
25
25
25
25
25
20m + 20m 20m + 20 m
12m + 12m 12m + 12m
40m + 40m 40m + 40m
35m + 35m 35m + 35m
35m + 35m 35m + 35m
40m + 40m 40m + 40m
40m + 40m 40m + 40m
86.9%=B
86.7%=B
90.3% =A
90.2% =A
90.1%=A
90.4% =A
90.5% = A
5 9%
5 9%
5 9%
5 9%
5 9%
WARRANTY CONDITIONS LIFETIME PARTS AND LABOUR WARRANTY ON ALL COMPONENTS Subject to: 1. Registration of installation. 2. Satisfactory completion of Benchmark logbook. 3. Service after 12 months by Halstead approved engineers.
Halstead Boilers Limited, 20/22 First Avenue, Bluebridge Industrial Estate, Halstead, Essex CO9 2EX For all telephone enquiries call: 0844 371 1111 Email:
[email protected] or
[email protected] or
[email protected] British Gas Service Listed Gas Council Numbers 47-260-16 41-260-24 47-260-17 41-260-25 47-260-18 47-260-19 47-260-20
Website: www.halsteadboilers.co.uk 0086 EC 87/BQ/44
Halstead Boilers is continuously improving its products and may therefore change specifications without prior notice. The statutory rights of the consumer are not affected. htdl/09/08
FOR ALL TELEPHONE ENQUIRIES CALL: 0844 371 1111
iHeat new thinking in boiler design
Artwork v2
AINING
ndensing, combi other boilers
Call Us
4 371 1111
9/9/08
14:17
Page 4
iHeat Combi
iHeat System
BAND A – 25C, 30C & 35C
MODEL 25S
OVERVIEW
OVERVIEW
iHeat Open Vent MODEL 20 OV
SEDBUK ‘A’ RATED
SELF DIAGNOSTIC
SEDBUK ‘A’ RATED
SELF DIAGNOSTIC
UP TO 35% MORE EFFICIENT
FROST PROTECTION
UP TO 35% MORE EFFICIENT
FROST PROTECTION
100% PRE-SET & TESTED
PRE-HEAT FUNCTION
OPTIONAL CLOCK
PRE-HEAT FUNCTION
OPTIONAL CLOCK
SEDBUK ‘A’ RATED
SELF DIAGNOSTIC
FLEXIBLE FLUEING
LIFETIME WARRANTY
FLEXIBLE FLUEING
LIFETIME WARRANTY
FROST PROTECTION
OVERVIEW
100% PRE-SET & TESTED
LOW NOX CLASS 5
LOW NOX CLASS 5
UP TO 35% MORE EFFICIENT
ALUMINIUM HEAT EXCHANGER
ALUMINIUM HEAT EXCHANGER
PRE-HEAT FUNCTION
OPTIONAL CLOCK
FLEXIBLE FLUEING
LIFETIME WARRANTY
100% PRE-SET & TESTED
LOW NOX CLASS 5
USER FEATURES Sedbuk A rated
Sedbuk A rated
Low-NOx - Class-5 performance.
Low-NOx - Class-5 performance.
Up to 35% more efficient than standard efficiency conventional boilers, reducing running costs and helping to preserve the environment.
Reduces running costs by up to 35% more than a conventional boiler, helping to safeguard the environment.
Built-in frost thermostat protects the appliance from damage during periods of cold weather.
Anti-cycling control prevents energy wasteful on/off cycling and reduces wear and tear.
Compatible with RFTH1 and RFTHM wireless controls.
Versatile horizontal or vertical flueing options enables the boiler to be sited almost anywhere in the home.
Built-in frost thermostat protects the appliance from damage during periods of cold weather.
Electronic control panel ensures ease of use and adjustment of the appliance.
Integral clock/programmer aperture, enabling direct control over the central heating timings.
Versatile flueing options enable the boiler to be sited almost anywhere in the home.
Intuitive control panel ensures easy operation and adjustment of the appliance.
Cleanly styled, Italian designed casing blends easily into any setting.
Built-in thermoregulation to increase further fuel efficiency. Attach the outside weather compensation control to maximise energy efficiency.
Plated heat exchanger reduces the risk of scaling and comes with 5-year anti-scale warranty.
INSTALLER FEATURES
Cylinder Warranty Guarantee
A
YEAR
Parts and Labour Cylinder Warranty Guarantee
Patented aluminium heat exchanger providing excellent thermal transfer and anti-corrosion properties.
SEDBUK LIFE TIME
A pre-fixing jig and built-in filling loop gives easy SEDBUK SEDBUK 5 YEAR TRAINING
A A
Reduces running costs by up to 35% more than a conventional boiler, helping to safeguard the environment. New aluminium heat exchanger. This heat exchanger provides excellent thermal transfer and anti corrosion properties and is fully recyclable.
Integral clock/programmer aperture, enabling direct control over the central heating timings.
ANTI-PLUME FLUE KIT OPTIONS Warranty
Low-NOx - Class-5 performance.
Anti-cycling control prevents energy wasteful on/off cycling and reduces wear and tear.
Extremely high modulation ratio, increasing efficiency and component longevity.
SEDBUK 10 2 YEAR
Sedbuk A rated
Extremely high modulation ratio, increasing efficiency and component longevity.
Hot water pre-heat provides instant hot water at any time, saving time and energy.
25
USER FEATURES
Low pressure loss reduces noise and increases pump performance.
Built-in frost thermostat protects the appliance from damage during periods of cold weather.
2YEAR YEAR Parts and Labour
ALUMINIUM HEAT EXCHANGER
USER FEATURES
B
5 YEAR
2 YEAR
2 YEAR
ANTI-PLUME installation andHeat maintenance allowing thecombi system for condensing, Heat Exchanger Exchanger and other boilers Warranty Warranty FLUEtoKIT be connected and tested without the boiler needing Call Us 2 Years on 2 Years on OPTIONS 0844 371 1111 be in place. Other Parts Other Parts
Warranty
subject to conditions
Warranty
subject to conditions
25
TRAINING for condensing, combi YEAR and other boilers
toCylinder Call Us 0844 371 1111 Guarantee
Automatic bypass and easy-fit condense connection Factory set and tested for easy commissioning, no need to check burner pressure or carry out a combustion analysis check.
10 25 2 YEAR YEAR YEAR
Parts and Labour Cylinder Cylinder Warranty Guarantee Guarantee
SEDBUK SEDBUK SEDBUK SEDBUK SEDBUK SEDBUK 10 5ANTI-PLUME YEAR LIFE 5 YEAR LIFE INSTALLER FEATURES ANTI-PLUME Heat Exchanger Heat Exchanger 2 YEAR 2 YEAR YEAR Warranty FLUE KIT Warranty FLUE KIT TIME TIME Parts and Labour Warranty Cylinder 2 Years on 2 Years on Warranty
A A A BA
Warranty Guarantee
OPTIONS Warranty
B
TRAINING for condensing, combi
2 YEAR
and other boilers
Call Us Warranty
OPTIONS 1111 Other Parts Other Parts New aluminium heat exchanger. 0844 This 371 heat exchanger
subject to conditions
subject to conditions
25
TRAINING for condensing, combi YEAR and other boilers
Cylinder Call Us 0844 371 1111 Guarantee
provides excellent thermal transfer and anti corrosion properties and is fully recyclable.
Automatic modulation eliminates the need to range rate the boiler.
Factory set and tested for easy commissioning, no need to check burner pressure or carry out a combustion analysis check. Automatic modulation eliminates the need to range rate the boiler.
Self-start programming protects the pump and motorised valve from sticking during long periods of inactivity.
Self-start programming protects the pump from sticking during long periods of inactivity.
Anti-cycling control prevents energy wasteful on/off cycling and reduces wear and tear. Range of flueing options allows boiler to be sited in a wide range of domestic applications. Can be converted to LPG with LPG Kit.
10 25 2 YEAR YEAR YEAR
Parts and Labour Cylinder Cylinder Warranty Guarantee Guarantee
SEDBUK 10 LIFE YEAR TIME Cylinder
SEDBUK
A A
Warranty Guarantee
LIFE TIME
ANTI-PLUME FLUE KIT OPTIONS Warranty
SEDBUK SEDBUK SEDBUK INSTALLER FEATURES 5 YEAR
BA
B
2 YEAR
TRAINING
25
YEAR
for condensing, combi Heat Exchanger and other boilers Warranty Call Us Cylinder 2 Years on Factory set and tested for easy commissioning, check 0844 371 1111no need to Guarantee Other Parts
Warranty
burner pressure or carry out a combustion analysis check.
subject to conditions
Automatic modulation eliminates the need to range rate the boiler. Top & bottom pipe connections for flexibility and easy install. Requires only 1-metre minimum static head. Built-in frost protection, protects the appliance from damage during periods of cold weather. External pump must be connected directly to boiler to ensure this function operates. Pump anti-block eliminates the risk of pump seizure during periods of inactivity. Purge cycle feature. Boiler will automatically run a two minute purge cycle when the boiler is switched on for the first time before the burner ignites to expel any air that may be present in the system.