www.ctcu.com. Rackmount Switch. 4G LTE Router/Gateway. SyncE Switch/PoE Switch. FieldBus to Fiber Converter. EN 50155 Sw
Rackmount Switch 4G LTE Router/Gateway SyncE Switch/PoE Switch
w w w.c t c u.c o m
FieldBus to Fiber Converter EN 50155 Switch IEC 61850-3 Switch
Industrial Ethernet
Product Guide
EN50155
NEMA TS2
EN50121-4
EN61000-6-2 EN61000-6-4
e-Catalog
R
Industrial Product Category EN 50155 Switch Series PoE Series
SyncE Switch
IEC 61850-3
Ethernet Switch
Management Software SmartView
FieldBus to Fiber Converter
TM
Rackmount Switch Series • 1GbE/10GbE product portfolio • 24+4, 24+8, modular solutions • Up to 24 IEEE802.3at PoE ports • Up to 28 SFP GbE fiber ports • Supports 14 μ-Ring instance in one switch • Network recovery time in / under 10ms
Product Selection Table
Reliable Industrial Ethernet Products
• Ultra PoE++ 60W solution • 4KV surge & 2.25KV Hi-pot isolation protection • LAN extend up to 1.2Km with PoE power feeding • 24VDC power booster and regulate power output • Product range of switch, converter, extender and injector
• EN 50155 certified • IEC 61375 TTDP • Auto-bypass for failover • Power input range 24 to 110VDC • IEEE 802.3at PoE 8/12/16-port product portfolio • M12 connector, IP65/IP67 rugged design
Industrial Product Category
www.ctcu.com
Industrial Product Series
2018 Industrial Product Guide
4G LTE Series • 2 SIM slot for failover redundancy • GNSS: GPS/GLONASS/Galileo • LAN, DI/DO, RS-232/485 serial interface • IPsec VPN/Modbus RTU/TCP, Real-COM • IEEE802.11b/g/n/ac • Routing: RIP1/RIP2, OSPF, VRRP
R
1
www.ctcu.com
2018 Industrial Product Guide
2
R
2018 Industrial Product Guide
Industrial Product Series Negative Voltage
Rackmount Switches
µ-Ring
IEEE 1588 V2
Related Products ICS-G24044X / ICS-G24S4X / ICS-M2404X IGS-2408SM / IGS-M2404S IPS-M2404S
Please check page 14 for more details.
• 10G backbone for high bandwidth transmission • Each 10G switch support 14 ring for centralization • Full Gigabit 24+4, 24+8 and modular solutions • Up to 24 IEEE802.3at PoE ports
• Up to 28 SFP GbE fiber ports • Power station IEC 61850-3 certified • Dual and wide range power input for power failure redundancy
10G Backbone with µ-Ring Technology Up to 14 rings
10G Core Switch
10G Core Switch
10G Backbone
10G
10G
10G Core Switch
10G Core Switch
Up to 14 rings
SyncE Switches
Negative Voltage
E IEEE 1588 V2
µ-Ring
SyncE
Related Products IGS-1608SM-SE / IGS-804SM-SE
Please check page 14 for more details.
• Supports Sync. Ethernet allow operators to deliver service with optimal stability and continuity in end-to-end connectivity • Supports IEEE1588 PTP V2 for precise time synchronization to operate in Ordinary-Boundary, Peer to Peer Transparent Clock, End to End Transparent Clock, Master, Slave mode by each port
• Supports negative voltage power input • 2.25K VDC Hi-pot isolation protection for Ethernet ports and power • 4KV surge protection for UTP and Fiber ports
Mobile Backhaul Application
SyncE
Base Station
Primary Reference Clock (PRC)
IGS-1608SM-SE IGS-804SM-SE
4G LTE
SyncE
GbE 4G LTE
Backbone Network
3
www.ctcu.com
Industrial Product Category
www.ctcu.com
X
Code
EN50155
IP64/67
µ-Ring
Please check page 14 for more details.
• Wide range products of 5, 8+2,12+4, 22+4 Ethernet port available • IEEE802.3af/at PoE 8, 12, 16-port for PD connection • Fast Ethernet M12 D-code, Gigabit M12 X-code • Supports 2 copper bypass for failover pass-through • Certificated EN50155, EN50121-4, IEC 61375-2-3/5 TTDP, EN45545-2 • IP64/67 rugged metal housing design Supports 24~110VDC Power Input
Smart Train Modern transportation systems for rail are now incorporating many IOT devices, including PoE IP cameras, Wireless Access Points for Hotspots, Voice over IP communications, monitoring and digital signage. Ethernet switches, provided by CTC Union, for this market segment, include EN50155 certifications, utilize rugged M12 connectors and provide a wide range for DC power connections.
• PIS • CCTV • WiFi Series • Intercom System
Controller
TTDP
Monitor
4G Router
Gateway WiFi
TTDP (Train Topology Discovery Protocol) for train inauguration is a process where the network devices can automatically reconfigure for topology changes (i.e., as carriages are swapped). TTDP identifies the order of the Ethernet switches in a train backbone from the head and allows auto-reconfiguration of the other switches in the entire network.
Car 1
Car 2
Car 1
Car 2
Exchange
Reliable Industrial Ethernet Products
Industrial Product Series
Related Products ITP-2204 / 1204 / G802 / 802 / 800 / 500 Series
Product Selection Table
EN 50155 Switches
EN45545-2
Add
Car 3
Remove
Remove & Add
Resilient Bypass EN50155 compliant products offer two copper interfaces with auto bypass function in the event of sudden power loss, particularly in daisy chain or linear topology networks. When power failure occurs in one of the switches on a train, the bypass relay function can activate, automatically bypassing the internal circuits and maintaining link between neighboring equipment. With this function, secure data transmission from terminals to backbone and higher network availability can be guaranteed. Bypassing
R
2018 Industrial Product Guide
4
R
2018 Industrial Product Guide
Industrial Product Series PoE Series Related Products IGS-2408 / 1608 / 803 / 402 / 600 Series IEXT224-4PH INJ-IG60-24 / INJ-IG01-PH
Please check page 15, 16 & 17 for more details.
PoE Switches • Supports PoE/PoE+/PoE++ IEEE802.3af/at/bt: 15.4/30/36/60Watts high power budget • Up to 8-port PoE (DIN-RAIL models) and 24-port PoE (Rackmount) • Redundant dual power input of 24/48VDC (20~57VDC), supports negative power (-)48VDC • High efficiency of power boost (94%~97%) • Supports 4KV surge protection and 2.25KV Hi-pot isolation • Advance PoE management: PD auto check and reset, PoE on/off scheduling (weekly/hour)
Remote PD Auto Test & Reset Auto checking and auto reset Powered Devices (PDs), when PD link failure The feature helps to reduce the operation and maintenance cost
Step 1
Step 2
PD Status is Good
No Response from PD
PD PoE Camera
PD Status Good!
Reset PD
PD Alive!
No Response...
Testing Request
Step 3
Testing Request Testing Echo
PoE
Power OFF
Power ON
Bus Surveillance System – 24VDC power booster required As IEEE 802.3af/at standard require the power input of 44~57VDC to supply PDs 15.4~30W power feeding. The dilemma of many applications that only 24VDC power be available, typically of Vehicles/Buses battery source. CTC Union PoE switches, design with the power booster circuit are able to boost input power from 24VDC to 48~57VDC power output, to solve the difficult situation of connect with PoE camera on bus surveillance application.
Camera 2
Camera 3
NVR
Monitor 1
Camera 1
24VDC Output Power Battery
Supports 24VDC power Input on vehicles application
5
www.ctcu.com
Industrial Product Category
www.ctcu.com
Negative Voltage IEEE 1588 V2
PoE LAN Extender • High-speed long distance copper connections; up to 300m at 100Mbps and up to 1.2km at 50Mbps (over coaxial cable); 16Mbps (over twisted-pair copper wires) • Complies with IEEE 802.3at PoE long distance; up to 300m at 30W power budget over coaxial cable • Plug and Play to reduces configuration time • One step to upgrade the existing CCTV to IP cameras Please check page 14 for more details.
Industrial Product Series
NEMA TS2
24AWG Copper Wire SNR
6dB
6dB
Profile
Asymmetrical
Symmetrical
Distance
Upstream Rate (Mbps)
Downstream Rate (Mbps)
Upstream Rate (Mbps)
Downstream Rate (Mbps)
300 m 400 m 600 m 800 m 1,000 m 1,200 m
65 45 30 10 6 1
100 95 65 45 35 20
100 70 45 27 18 8
100 70 45 27 18 16
PoE Output Budget
30W 20W 15W 7W 5W 4W
Reliable Industrial Ethernet Products
Regulated
Outdoor AP
Local Power
40-60 VDC or External AC to DC Adaptor
Ethernet
Don’t need power supply
up to 1.2km Copper/Coaxial
Ethernet
Remote Power Feeding IEXT224-4PH
Local
Data Power Simultaneously
IP Cam
Power IEEE802.3at PoE Data Fast Ethernet
IEXT224-4PH
e to lcom We
Total Power Budget of 30W for 4 PoE(PSE) Ports
Remote
Product Selection Table
Remote Power Feeding Enable
U CTC
Display
PoE Injectors • Easy to install PoE PD in the existing network topologies • Provides 1 port IEEE802.3af/at power supplying • Selectable 15.4/30W/36W,60W,72W PoE power output • Supports PoE mode A (Midspan) and mode B (Endspan) • Regulate PoE output voltage to stabilize power device, and guarantee the power feeding distance up to 100metter • Supports 4 pairs (60W/72W) PD handshake request ( such as AXIS® IP Camera) Please check page 15 for more details.
Gigabit Ethernet PoE Injector application Gigabit Ethernet
Gigabit Ethernet + PoE 15.4W
Non-PoE Ethernet Switch/HUB
/
30W
/
36W
/
60W
/
72W
INJ-IG60-24 & INJ-IG01-PH
PoE PD Device ®
ex. AXIS Q60 series in 60W mode
R
2018 Industrial Product Guide
6
R
2018 Industrial Product Guide
Industrial Product Series 4G WiFi Gateway / Router Related Products ICR-W403 / ICR-4103
WiFi
LTE
4G
Please check page 17 for more details.
ICR-W403
ICR-4103
• Provides dual 4G LTE Cellular SIMs for fail-over redundancy • High performance IEEE802.11a/b/g/n/ac (5GHz & 2.4GHz) connectivity • GNSS fleet tracking (GPS) • DI/DO port, Serial port ideal for IoT application • High security on various VPN protocols, built-in Firewall and Authentication • Ruggedized design with vibration, shock, wide operating temp. • Certified by EN 50155, E-Mark, EN 60950-1, CE, FCC
• Supports Multi-band 4G FDD/TDD LTE, WCDMA, GSM 900/1800MHz, LTE Cat4 • Built-in dual SIM card slots for network redundancy • Supports 2 DI, 1 DO interface • Supports 2 RS-232, 1 RS-485 (2-wire) Serial COM port • Integrated dual detachable antenna • Supports IPv6/IPv4, PPPoE, Static Routing and RIP1/2, Qos, VLAN, NAT
Wireless Transmission in Logistics Center
Vehicle Location Tracking System
7
www.ctcu.com
Transportation / Bus Communication 4G LTE
e
Eth
ter
ou
R iFi GW 3
t rne
4 -410 R IC
LED Display
4 -410 R IC
03
-41
TIM E
10:2
ter
ou
R iFi GW 3 ICR
esei NO 0 TA natio .115 IPEI n 5O N TI ME D
Remote Control Center
Billboard
Bus Location Ticketing Information
ter ou 03 Fi CRR-41 i GW I
Bus Stop
Industrial Product Series
Industrial Product Category
www.ctcu.com
Reliable Industrial Ethernet Products
4
Product Selection Table
FieldBus to Fiber Converters PROFIBUS
Related Products IFC-FDC-PRO / IFC-Serial-PRO / IFC-Serial-CAN IFC-FDC / IFC-Serial
Please check page 17 for more details.
• Redundant fiber ring with zero recovery time • Auto baudrate detection and data speed up to 12Mbps for ProfiBus series • Protocol transparent of Modbus, ProfiBus and CAN bus • Alarm by relay output • 2.5KV isolation protection • Dual-power inputs for redundancy • Extends PROFIBUS transmission distance up to 60 km • Wide temperature range model available for -40 to 75°C environments
PROFIBUS Network Benefits
IFC-FDC-PRO
PLC
Sensor
HMI
Digital power meters 0004 12
IFC-FDC-PRO
Fiber PROFIBUS
5F
Fiber Ring
1. EMC/noise isolation, to reduce mutual interference between serial port device 2. Extend distance by fiber 3. Cable redundancy 4. Isolate PROFIBUS failure 5. Achieve a reliable network environment PROFIBUS
0004 12
5F
Digital HMI power meters IFC-FDC-PRO
Sensor
PLC
IFC-FDC-PRO IFC-FDC-PRO
R
2018 Industrial Product Guide
8
R
2018 Industrial Product Guide
Industrial Product Series Negative Voltage
IEC 61850-3 Switches
IEC 61850-3
GOOSE
Related Products IPS-M2404S / IPS-G803SM / IPS-803GSM
Please check page 17 for more details.
• IEC 61850-3, IEEE 1613 certified is designed to fulfill power substations • Supports µ-Ring and µ-Chain, RSTP/STP/MSTP, and ERPS G.8032 for network redundancy • Isolated redundant power supplies with universal 24/48 VDC or 110/220 VDC/VAC power supply range • Hot-swappable interface modules for rackmount model • Cable diagnostic and Green Ethernet • -40 to 85°C operating temperature range
GOOSE Message For mission-critical applications, GOOSE messages can be placed into the highest QoS priority so as to avoid packet loss and delay. • IPS series Ethernet switches can communicate with GOOSE multicasts. • Critical communications are prioritized with the highest QoS priority. • Achieve zero packet loss to ensure reliable transmissions.
Hydroelectric Power Stations
Wind Power Plant
GOOSE
Solar Energy Power Plant
Power Substation
Power Substation Primary Reference Clock (PRC)
IEEE 1588v2
SCADA Wind farm
Solar power
Hydroelectric power
Nuclear power
E OS GO V2 588 E1 E E I
Thermal Power
µ-Ring E OS V2 GO 588 E1 E E I
PLC
GO OS IEE E E1 588 V2 PLC
VT/CT IDE
9
www.ctcu.com
Electric power sensor
VT/CT
Power Substation
Reliability Elements Certification ● ● ● ●
CE/FCC UL 60950-1 EN 50155 EN 50121-4
● ● ● ●
IEC 61850-3 EN 61000-6-2 EN 61000-6-4 NEMA TS2
Redundant Ring ● ● ● ● ●
µ-Ring ITU-T G.8032 802.1d STP 802.1w RSTP 802.1s MSTP
EMS Industrial Grade ● ● ● ● ●
u-Ring
EN 61000-4-2 ESD Level 3 EN 61000-4-3 RS Level 3 EN 61000-4-4 EFT Level 3 EN 61000-4-5 Surge Level 3 EN 61000-4-6 CS Level 3
Industrial Product Series
Reliable Industrial Ethernet Products
Industrial Product Category
www.ctcu.com
Rugged Mechanical
● Wide Temperature Models Available
● Vibration IEC 600068-2-6 ● Free Fall IEC 600068-2-32 ● Shock IEC 600068-2-27
High MTBF & 5 Years Warranty ● Industrial Grade Component ● Fanless
Brief Comparison between general CE & EN50121-4 Surge Signal L-E Signal L-L DC Power L-E DC Power L-L ESD (Contact) Radio frequency magnetic field EFT (fast transient) Power magnetic field Pulse magnetic field
CE Compliant
EN50121-4 Compliant (Trackside)
1kV N/A 0.5kV 0.5kV 4kV 10V/m 0.5kV Criteria B* 10 A/meter N/A
2kV 2kV 2kV 2kV 6kV 20V/m 2kV Criteria A* 300 A/meter 300 A/meter
Product Selection Table
Temperature
Reliable Industrial Ethernet Products
Reliable
* Criteria A: During the test storage devices shall maintain normal operation both in read/write and in stand-by conditions. * Criteria B: During and after the test failures which can be recovered by read and write retires are permissible (temporary delay in processing caused by this process is acceptable).
Key Certifications To reduce risks of electric shocks, fire, energy related hazards, heat related hazards, mechanical hazards, radiation, and chemical hazards for operator, layman or service personnel.
EN61000-6-2 EN61000-6-4
For Heavy Industrial Environment application.
E13
For car and motorcycle spare parts and security products, noise and emissions, are required to act in accordance with the EU.
For traffic control. NEMA TS2
EN50155
For trackside and railway applications. EN50121-4
For rolling stock, vehicle and moving machine applications.
For power substation applications. IEC 61850-3
R
2018 Industrial Product Guide
10
R
2018 Industrial Product Guide
Reliable Industrial Ethernet Products Advanced 4KV Surge Protection for PoE & UTP PoE Switch
Surge Protect
4KV Supports Negative Power Input • RS232 ground isolation from power ground
• Reverse polarity protection
• Negative Power System
V-
• Reverse Polarity Protection
V-
-48
V+
-48
V+
RS232
RS232
No Protection
Isolation
Not support Negative Power Model
V-
0
V+
+48V
Reverse Polarity Protection
Supports Negative Power Model
Management Software TM
CTC Union’s Industrial Device Management System is a comprehensive management tool, including SmartView Element Management System (EMS), TM
Central EMS and SmartConfig . Whether it is for monitoring, configuration, maintenance, or troubleshooting, the management software has a tool for every task.
SmartView
TM
EMS
TM
SmartConfig
• Main Functions (FCAPS) : Fault, Configuration, Accounting, Performance and Security Management • Remote access control for efficient configuration • Traffic / performance monitoring and management • Alarm trap and event log management • Auto discovery and device Viewer • Allow up to 25 administrators to login
• Multiple device auto discovery • Group configuration, access • Group firmware upgrade • Backup / restore device configuration • IP address assignment • Connectivity testing
Please check the Industrial catalog chapter 1 for more details.
11
www.ctcu.com
Industrial Product Category
www.ctcu.com
Powerful Cybersecurity - Port Security Static MAC Table Configuration
Delete
Add the allowed MAC address
VLAN ID 1
MAC Address F0-DE-F1-0B-65-8D
1
Port Members 2 3
Industrial Product Series
Step1
System Configuration Mode
Enable
Aging Enable Aging Period
Step2 Enable un-know MAC limit at zero
3600 Seconds
Port Configuration Disable
Mode
Limit 4
None
Action
Disabled 1
State
2
Enable
0
Shutdown
Ready
Reliable Industrial Ethernet Products
Port 1
MAC Whitelist
Hacker’s MAC
Product Selection Table
F0-DE-F1-0B-65-8D F0-DC-F1-5B-70-2D F0-DF-F1-4B-72-9D F0-DA-F4-3C-22-1A
AB-CD-EF-0B-65-4W
Powerful Cybersecurity - NAS RADIUS/ ISE Server
IEEE802.1X Authentication
Send access request for authentication by ID
Send username & password
NAS
RADIUS/ ISE Server Learn & authenticate the source MAC address
Send MAC address (First packet)
MAB
(MAC Authentication Bypass) Port Configuration
Port
Admin State
1
MAC-based Auth.
2
Force Authorized
NAS RADIUS-Assigned Qos Enable
RADIUS-Assigned VLAN Enable
Guest VLAN Enable
1
R
2018 Industrial Product Guide
12
R
2018 Industrial Product Guide
Reliable Industrial Ethernet Products IEEE 1588 PTP v2 in Smart Grids S Power Substation
Supports 5 operating mode
IEEE 1588 v2
S IEEE 1588 v2
• Ordinary-Boundary • Peer to Peer Transparent Clock • End to End Transparent Clock • Master • Slave
S
M
Wind Power Plant
Backbone Network
S
Solar Energy Power Plant
S Slave
Primary Reference Clock (PRC)
IEEE 1588 PTP v2 Application in Power substation & Smart Grid
M Master
µ-Ring Network Redundancy The µ-Ring is a proprietary redundancy protocol developed by CTC Union that supports flexible ring topologies. Multiple µ-Ring
• Friendly µ-Ring Configuration
Master
1 2 3 4 5
• Up to 5 rings • Up to 250 devices in a ring • µ-Ring, µ-Chain, Sub-Ring for different applications • Recovery time < 10ms • User Friendly configuration GUI
• µ-Chain topology • Benefit: Mix CTC and third party device in a ring topology Third Party Network
Slave
Edge
• Sub-Ring topology • Benefit: 1. Device redundancy (A & B)
Backup Path
Edge
Master
Ring
B
Backup Path
A
µ-Chain Slave
2. Cable redundancy
Slave
Backup Path
Sub-Ring
Slave
Supports Standard ITU G.8032 ERPS, MSTP, RSTP, STP for Network Redundancy
ITU G.8032
13
www.ctcu.com
Other than the proprietary µ-Ring redundancy protocol, standard ring redundancy protocols such as ITU G.8032 ERPS, STP, RSTP and MSTP are also supported. Among standard redundancy protocols, G.8032 ERPS, achieves the fastest recovery time (