NetworX control panels
NetworX
A complete range of control panels for residential and commercial applications DOOR CONTROL
PSTN, GSM/GPRS TCP/IP
NETWORX
INTRUSION & FIRE
HARDWIRE, WIRELESS & 2/ ADDRESSABL GE /
NetworX series One product line that does it all Can be used in most any installation, yet simple enough to learn only once Convenient: program all panels (from 4 to 192 zones) the same way Flexible: install multiple modules in one enclosure Expandable: add zones quickly and cost-effectively Reliable: leading-edge wireless technology provides optimal performance Scalable: configure system easily to meet your customer’s needs 3/ GE /
NetworX series standardizing Lower overhead costs for the installation company alarm companies can be trained on one control with: Consistent programming Consistent wiring Consistent downloading techniques Consistent end user interface
4/ GE /
NetworX family
NX-8E NX-8EUR NX-6EUR NX-4EUR 5/ GE /
NetworX series characteristics Unique distributed intelligence architecture Allows low cost entry level product capable of expanding and growing as technology shifts. Upgrade path - Often new technology can be added without modification to existing panels and modules. High speed Flash processors allows to service your needs quickly and efficiently. World wide field proven state of the art core design.
6/ GE /
NetworX series characteristics All zones programmable as fire or burglary 30 customizable pre-configured zone types Up/downloadable with competitor lockout Fuseless design 4 on-board outputs on NX-8E, NX-8-EUR and NX-6-EUR 2 on-board outputs on NX-4-EUR 4-wire smoke detectors on all panels Dedicated 2-wire zone on NX-8E, NX-8-EUR and NX-6EUR (not on NX-4-EUR)
7/ GE /
NetworX series characteristics Force arming by zone type Automatic arming/disarming with auto retry Built-in siren driver/voltage output (programmable) Voltage and current telephone line monitor on all panels Dynamic battery test Quality test of battery during arming or during manual test (*44) Battery missing test each 12 sec. Box tamper input
8/ GE /
NetworX Panel characteristics
NX-8E NX-8-EUR NX-6-EUR NX-4-EUR 9/ GE /
NX-8E typical characteristics 8 zones, 8 partitions, 240 users (4 or 6 digits) Zone expansion to 192 hardwired/wireless or addressable zones Maximum of 8 keypads per partition Maximum of 32 keypads per system Maximum of 32 devices per system Includes keypads and expansion modules 512 event history log with: Date, time, event, partition number, user number
10 / GE /
NX-8-EUR typical characteristics 8 zones, 8 partitions, 99 users (4-digit) or 66 (6-digit) Zone expansion to 48 hardwired/wireless or addressable zones Maximum of 8 keypads per partition Maximum of 24 keypads per system Maximum of 32 devices per system Includes keypads and expansion modules 512 event history log with: Date, time, event, partition number, user number
11 / GE /
NX-6-EUR typical characteristics 6 zones, 2 partitions, 40 users (4 or 6 digits) Zone expansion available to 16 zones (wireless) Maximum of 8 keypads per partition Maximum of 3 devices per system Keypads not included 512 event history log with: Date, time, event, partition number, user number
12 / GE /
NX-4-EUR typical characteristics 4 zones, 1 partition, 8 users (4 or 6 digits) Zone expansion available to 8 zones Wireless using RF receiver (8 zones maximum) Maximum of 8 keypads Maximum of 2 modules per system 512 event history log with: Date, time, event, partition number, user number
13 / GE /
NetworX
SIA False Alarm Prevention Features
14 / GE /
SIA False Alarm prevention features Audible / Visual Exit Delay Countdown Warning Keypad beeps slowly until the last 10 seconds of the exit delay During the last 10 seconds the keypad beeps quickly, and the exit light flashes
15 / GE /
SIA False Alarm prevention features Exit Error Reporting A special report to the central station that indicates the exit door had not closed at the time the exit delay expired Indicates to the central station that the alarm was caused by user error
16 / GE /
SIA False Alarm prevention features Recent Closing Reports Advises the central station that a zone alarm occurred within 5 minutes of a closing This will let the central station know that there is the possibility of an improper arming or exit
17 / GE /
SIA False Alarm prevention features Programmable Abort Delay (Cancel) Alarm can be programmed to delay reporting to central station Siren or bell will sound During the dialer delay the user can enter a code to prevent signal being sent to central station If the dialer delay has expired, the alarm can be cancelled by entering a user code followed by the CANCEL button. Visible confirmation of cancellation Cancel report sent to the central station 18 / GE /
SIA False Alarm prevention features Cross Zoning Requires 2 trips from separate zones to cause alarm Useful for eliminating problems with pets Useful for eliminating false alarms Set two or more zones as cross zones, then set cross zone time Setting a single zone as a cross zone will cause a double trip zone, “double knock”
19 / GE /
SIA False Alarm prevention features Swinger Shutdown By Zone Control panel will only report a fault on the zone a programmable number of times before bypassing that zone Used to limit problems caused by a single detector Programmable by zone configuration group Only affects a single arming cycle
20 / GE /
SIA False Alarm prevention features Fire Alarm Verification Requires 2 trips of a smoke detector First trip causes panel to reset smoke power Second trip within a programmable period of time causes alarm Reduces system caused false alarms
21 / GE /
NetworX - Keypads
A complete range of user friendly keypads compatible on all NetworX control panels
22 / GE /
NX-1xx Series keypads
• • • •
NX108 NX116
•
8, 16 and 24 zone LED keypads 5 user friendly function buttons 6 service LED’s Quick buttons for: Fire Medical Hold-up alarm Unique Ding-Dong chime
NX124
23 / GE /
NX-13xx Series keypads
•
• • •
NX-1308
NX-1316
•
8, 16 and 24 zone LED keypads with removable door 5 user friendly function buttons 6 service LED’s Quick buttons for: Fire Medical Hold-up alarm Unique Ding-Dong chime
NX-1324
24 / GE /
NX-15xx Series keypads
•
• • • NX-1508
•
8 and 16 zone “Slim-line” LED keypads with removable door 5 user friendly function buttons 6 service LED’s Quick buttons for: Fire Medical Hold-up alarm Unique Ding-Dong chime
NX-1516 25 / GE /
NX-148 LCD keypad
•
• • • • •
•
192 zone design LCD keypad with removable door Dual language keypad 5 user friendly function buttons Menu driven user functions 4 service LED’s Quick buttons for: Fire Medical Hold-up alarm Unique Ding-Dong chime 26 / GE /
NX-1348E ICON keypad
•
• • •
•
48 zone design ICON keypad with removable door Passive display including fixed ICONS 5 user friendly function buttons Quick buttons for: Fire Medical Hold-up alarm Unique Ding-Dong chime
27 / GE /
NX-12xx Series keypads
NX-1248E
•
• • •
192 zone dual language LCD keypad with “reversed” display and door 4 user friendly function buttons Menu driven user functions Additional “Night mode” button
NX-1208E
• • •
8 zone LED keypad with door 4 user friendly function buttons Additional “Night mode” button
28 / GE /
General keypad features Maximum keypad or module distance is 800 meters from the panel Backlit keys with audible feedback Armed, Ready, Power and Service LED's Independently adjustable keypad tones Full keypad supervision (polling) Alarm memory feature Set system date and time Download call back initiation (with command *98)
29 / GE /
NetworX - Modules
A complete range of auxiliary modules compatible on all NetworX control panels
30 / GE /
Zone expanders
31 / GE /
NX-216 Zone expanders •
NX-216 • 16-zone expander up to 48 zones for NX-8-EUR • Additional tamper input • 12Vdc power supply (100 mA)
•
NX-216E • 16-zone expander up to 192 zones for NX-8E • Additional tamper input • 12Vdc power supply (100 mA)
•
NX-216Z8 • 8-zone expander • Additional tamper input • 12Vdc power supply (100 mA)
32 / GE /
Output expanders
33 / GE /
NX-507E & NX-508E Output expanders •
NX-507E : Relay module • 7 SPDT dry relays, 1 open collector • Up to 8 modules per system • additional tamper input • X-10 output
•
NX-508E : Open collector module • • • • •
8 open collectors Up to 8 modules per system Additional tamper input X-10 output Parallel printer output 34 / GE /
Additional power supply
35 / GE /
NX-320E Smart power supply • • • • • •
3 programmable outputs Maximum 2 Amp Bus amplifier +800 meters Supervised siren output Additional tamper input Up to 4 modules per system
36 / GE /
Two-wayvoice module
37 / GE /
NX-534E Two-way-voice module •
NX-534E : Two way voice module • Two way voice verification Central station Mobile phone
• 2 microphone inputs • 1 loudspeaker output
NX-534E
3510
3520
•
3510 : Loudspeaker/microphone
•
3520 : Microphone
38 / GE /
Voice speech module
39 / GE /
NX-535 Voice speech module • • • • • • •
Adds vocal reporting features to the NetworX range Messages can be assigned to events 1 leader message 16 alarm (event) messages 1 address message 160 sec high quality audio Easy programming through telephone handset
40 / GE /
Home automation interface 41 / GE /
NX-584E Home automation interface •
Full-duplex serial port to interface to: Building management systems Access control …
•
Allows seamless integration with third party providers e.g.
Elk Products Keri Systems Crestron Home Panja AES Intellinet
42 / GE /
Direct connect module
43 / GE /
NX-586E Direct connect module • • •
•
Interface for on-site programming with PC No need for a telephone line and modem 4 templates to store up to 4 panel configurations, so there is no need for a PC at the installation site Can be used as portable memory device
44 / GE /
Virtual keypad
45 / GE /
NX-587E ‘Virtual Keypad’ > Enables any remote system to use RS-232 to communicate with any NetworX control panel > Dongle design > Connected to the NetworX buss > No special message formatting and checksums to allow easy integration > Passes all text, LED and buzzer conditions > English operation
46 / GE /
NX-587E ‘Virtual Keypad’ > Module uses fixed address number 248 > Connect to PC COM port (9600 baud, 8 data bits, 1 stop bit and no parity. > Connect to NX panel 2=COM 3=POS 4=DATA
47 / GE /
NX-587E ‘Virtual Keypad’
48 / GE /
Flash tool
49 / GE /
NX-588E ‘Flash Tool’ > To store and upgrade firmware for flashable NX panels and certain NX modules > To store up to 4 panel configurations (NX-586E) > Connects to USB port of PC > Install NXProg Tool on PC to load .flx file to NX-588E
50 / GE /
NX-588E ‘Flash Tool’
1. Launch NXProg panel/module 2. Open .flx file
3. Transfer File to NX-588E
4. Upgrade firmware
51 / GE /
Door control ProxReader 52 / GE /
NX-1701E ProxReader •
NX-1705E
NX-1701E
NX-1706E
Up to 15 readers (depending on panel type) • Single- Double- and Scan hold functions Code entry Arm in “Stay” or in “Away” mode Disarm control panel Trigger Aux function 1 or 2 Broadcast an X-10 function Activate driver output (Request To Exit) • For indoor and outdoor applications
53 / GE /
NX-1701E ProxReader > > > >
Uses propriety Smart Reader Technology (TECOM) Connects directly to the NetworX keypad bus No dip switch setting for addressing the module Includes driver output (door strike) and egress input (Request-to Exit input) > Number of user cards related to the number of user codes in the panel – – – –
NX-8E > 240 users NX-8-EUR > 99 users NX-6-EUR > 40 users NX-4-EUR > 8 users 54 / GE /
NX-1701E ProxReader > Authority level of card follows user authority level in panel > Reader functions (single-scan, double-scan and singlescan- hold) can be linked to: - Code entry function - Arm in “stay” or in “away” mode - Disarm control panel - Trigger Aux function 1 or 2 - Broadcast an X-10 function - Activate relay driver output (Request To Exit)
> 4 Programmable timers : scan time, relay active time, door fault warning time and door fault alarm time 55 / GE /
NX-1701E ProxReader > Door shunt zone (access zone) : zone that will be monitored as a door for access control > Request to exit zone : zone that will be monitored to send out an RTE and to activate the reader onboard driver output
56 / GE /
NX-1701E ProxReader
Max.15 (depending on panel type)
57 / GE /
Door control Interface 58 / GE /
NX-1710E Door controller • • • •
Up to 16 modules 1 module supports up to 2 readers 16 doors / 32 readers Interfaces with most popular Wiegand readers :
26-bit standard Wiegand 27-bit Tecom ASC 35-bit HID Corporate 1000 40-bit with facility code (Casi Rusco 4001) 40-bit w/o facility code (Casi Rusco 4002)
59 / GE /
NX-1710E Door controller > Reader functions: – Single-scan – Single-scan-hold > Reader functions linked similar to NX-1701E > Connects directly to the NetworX keypad bus > Flash-based microprocessor (PIC18F452) > Tamper and egress input per reader > Buzzer output and 2 LED outputs per reader > 1 on-board relay output (250Vac/5A – 30Vdc/5A) > +5Vdc and +12Vdc to power the readers > zone input for monitoring a door contact 60 / GE /
NX-1710E Door controller
Max.16 (depending on panel type)
61 / GE /
Door control ProxPad 62 / GE /
NX-1750 ProxPad > Combination of a proximity card reader and a keypad allowing to control an access door and to show the system status > Treated as a normal keypad > Up to 3 scan functions – single scan (beep) – double scan (beep) – triple scan (beep) > Reader options similar to NX1701E
63 / GE /
NX-1750 ProxPad > > > > > > > > >
LED’s for armed status, ready to arm status and alarm LED’s for up to 8 zones status indication Set zone starting number Master mode Fire alarm LED Power LED Wall or recess mounting Fits in a standard electrical gang box Relay output to trigger door lock
64 / GE /
NetworX - Modules
A complete range of TCP/IP and GSM/GPRS communications
65 / GE /
IP and GSM/GPRS solutions
NX-590E NX-7002 Osborne-Hoffman receiver
IP and GSM/GPRS solutions GSM Voice GSM Data GSM GPRS
PSTN OH Network Receiver
Automation System
RS-232 Central Station
E-mail GSM SMS NetworX Panel
Local or Wide Area Network (LAN or WAN)
Ethernet TCP/IP
Download Computer DL900
Automation System
RS-232 Osborne-Hoffman 19” receiver Central Station
67 / GE /
TCP/IP interface
68 / GE /
NX-590E Internet/Intranet interface Connects NetworX panel to the network > Alarm reporting towards OH receiver (2) > Email reporting to 2 email accounts : POP3/SMTP server required, Microsoft Exchange is not supported > Up/downloading > Home Automation > Fixed IP or DHCP > Alarm reporting in SIA or CID > TCP/IP connection to OH Receiver > Supervised connection with configurable polling time > 3-DES (triple-Des) encrypted messages 69 / GE /
NX-590E Internet/Intranet interface > Flashable microcontroller > Linux Dragon-ball PC based, with RJ 45 Ethernet connector > Code update for the OS of the NX-590E can be flashed via DL900 > On-board RS232 port for easy verification during first start-ups 70 / GE /
NX-590E Internet/Intranet interface Email notification examples
71 / GE /
GSM/GPRS interface
72 / GE /
NX-7002 GSM/GPRS interface Wireless alarm reporting : > SMS messages in - SIA : ex >1234 BA001 - CID : ex 12341811370100 > over GSM voice channel using any panel dialler format (SIA, CID, Vocal, etc)
73 / GE /
NX-7002 GSM/GPRS interface Wireless alarm reporting (cont’d) : > Via GPRS over TCP/IP in SIA and CID format – 3-Des Encrypted messages to TCP/IP Receiver – Supervised connection (polling) > Backup for panel dialer or auxiliary dialer Wireless up/downloading – Using GSM Data channel at 9600Bd (CSD) – Using GPRS (only site initiated, *98)
74 / GE /
NX-7002 GSM/GPRS interface > > > > > > >
Connects to the NetworX bus Audio tap connector GSM/GPRS modem card Antenna SIM card holder Battery leads Status LED’s
75 / GE /
NX-7002 SIM card requirements > SIM Pin Code > SMS service centre number – alarm reporting using SMS messages > Voice number – alarm reporting over GSM Voice channel > Data number – U/D over GSM Data Channel > GPRS APN – alarm reporting towards TCP/IP OH receiver – Enable : GPRS Access Point Name PPP password & login (only when required by provider) 76 / GE /
NX-7002 : how it reports 4 x Report Control destinations : • SMS mobile phone 1 • SMS mobile phone 2
Backup destination : • • • •
SMS mobile phone 1 SMS mobile phone 2 TCP/IP receiver 1 TCP/IP receiver 2
or other dialler :
Report control : • primary report = NX-7002 will always report • backup report = NX-7002 will only report when primary dialler fails
77 / GE /
NX-7002 : TCP/IP reporting > Report Control destinations : – TCP/IP receiver 1 – TCP/IP receiver 2 > Reporting format : SIA only > Settings for receivers : – IP address OH TCP/IP receiver 1 – IP address OH TCP/IP receiver 2 > Receiver number and line number > Alarm port number (9999) > Set account code(s) > Enable polling (1-255min) for supervised connection 78 / GE /
NX-7002 Voice channel reporting > As primary reporting (all programming in control panel) – Program phone number in panel and put an ‘A’ in front of it example : A027253039 – Supports panel Protocols (SIA, CID, voice, etc) > As backup reporting (all programming in control panel) – Program phone number 1 in panel example : 027253039 – Program phone number 2 in panel with an ‘A’ in front of it example : A027253039 > As backup reporting using new panel feature (loc.37-7-1 in panel)
79 / GE /
NX-7002 Supervision > Status LED’s on board > RSSI value (loc 172) > Status Flags (loc 174) : – option 1 ON = Communication with GSM modem OK – option 2 ON = SIM card PIN is OK – option 3 ON = Logged in to the GSM network – option 4 ON = Sending SMS – option 5 ON = Using GSM audio connection – option 6 ON = Using GSM CSD connection – option 7 ON = Connected to GPRS network – option 8 ON = SIM card PUK code required 80 / GE /
NX-7002 SMS text messages > Added 8 SMS report controls (Loc 1) > Select events for each report control (Loc 4) > Allows to report towards max. 16 mobile phone numbers (loc 232) > Assign report control(s) to mobile phone (loc 228) > Fixed SMS messages > Up to 12 languages supported > Retrieves zone text information from keypad (language 1)
81 / GE /
NX-7002 SMS text messages > Up to 12 languages supported (loc 264) : language ISO-639 language Danish dan Italian Dutch nla Norwegian English eng Polish Finnish fin Portuguese French fra Spanish German deu Swedish
ISO-639 ita nor pol por esl sve
82 / GE /
NX-7002 SMS text messages > Example : 03/03 03/03 03/03 03/03
10:36 10:38 10:38 10:38
Close(Arm) P1 User 1 Alarm P1 Kitchen Open (Disarm) P1 User 1 Alarm Restore P1 Kitchen
03/03 10:46 Close (Arm) P1 User 98
83 / GE /
NX-7002 SMS text messages > SMS forwarding (loc 200-2-4) Sends unrecognized SMS messages to administrator phone (mobile phone 1).
84 / GE /
NX-7002 SMS Control – version 5 > Fixed SMS command messages (loc 200-2) to receive system status, arm/disarm, user code maintenance, etc ... > Option to allow authorized phone numbers only > Option for password protection
85 / GE /
NX-7002 How to flash upgrade ? Use the NX-7002 Flash to upgrade your GSM module Connect 12Vdc power to the NX-7002Flash Connect serial cable to your PC or labtop Start Hyperterminal and select 115200-8-N-1-NO Select Transfer - Send File Select Protocol Xmodem and browse for the software file Plug the NX-7002Flash onto the GSM module and program the module LED "success" should light up after a succesfull load.
86 / GE /
TCP/IP Network receiver 87 / GE /
Alarm Receiving with OH-NetRec v1.9.3 > Simulates OH or Surgard to Automation Software via RS232 port of the TCP/IP Receiver > Software installed on PC as service application > Fixed IP address > Free demo version up to 5 accounts > Different licensing schemes (100, 1.000 or 10.000 accounts) > Active panel list > Support for VVMIQ Video Clips.
88 / GE /
Alarm Receiving with OH-NetRec v1.9.3 > Support for 6 different Supervision Windows. Depending on the Alarm Reporting port, the OH NetRec will apply different line-cut time-outs : port 9999 (default) port 8995 port 8994 port 8993 port 8992 port 8991
default line-cut timeout = 2 min default line-cut timeout = 5 min default line-cut timeout = 1 hour default line-cut timeout = 8 hours default line-cut timeout = 24 hours default line-cut timeout = 7 days
When panels reporting via NX-7002 GPRS (typical hours/days polling time) or via NX-590E (typical 20 sec polling time), program the corresponding alarm port in the module. 89 / GE /
Alarm Receiving with OH-NetRec v1.9.3 > Enable GPRS-flag if port used for GPRS communication > Overwrite of the Receiver & Linecard number on the OH Net Rec. The R&L from the panel are overwritten when transmitted to the Automation Software. In this case the installer does no longer need to program this in the NX590E/NX-7002. > Event printing directly from the OH Software, to a printer connected to the PC
90 / GE /
NetworX
A complete range of wireless solutions compatible on all NetworX panels
91 / GE /
Wireless 433.92 Mhz 92 / GE /
Wireless 433 Mhz • All NetworX panels can be wireless expanded by adding an additional wireless receiver • Three types of receivers (8, 16 and 48 zones) are available depending on the application and type of control panel used TM • Receiver can be mounted in the X-pand-A-Can enclosure with the control panel, or can be mounted in the NX-469 receiver enclosure • Up to four receivers can be used on a single NX8-EUR, up to 8 on the NX-8E
93 / GE /
NX-4xxE-I Wireless receivers •
• •
NX-469
• •
•
Models available • NX-408E-I : 8 zones • NX-416E-I : 16 zones • NX-448E-I : 48 zones Frequency 433,92 MHz Supervision of all transmitters each 64 minutes (except keyfob and panic) Optional jamming detection Optional tamper detection when removing antennas NX-469 : Enclosure for 433MHz wireless receivers
NX-4xxE-I
94 / GE /
NX-45xN-I Door/window transmitters •
• • • • • • NX-450N-I
NX-451N-I
•
Models available • NX-450N-I : White • NX-451N-I : Brown 2 internal reeds switches Sends supervisory signal each 64 min. Powered with 3V Lithium battery Typical battery life: 5-8 years Additional supervised input Transmission range 150m (open air) Tamper switch
95 / GE /
NX-455-I Recessed D/W Transmitter • • • • • •
Available in white Sends supervisory signal each 64 min. Powered with 3.0V Lithium battery Typical battery life: 10 years Compact size ensuring effortless and discreet installation Tamper switch
NX-455-I
96 / GE /
NX-470-I 4-button keyfob • • • • •
NX-470-I
•
Not supervised Powered with 12, 33mAh alkaline battery Typical battery life: 5-8 years Transmission range 150m (open air) Functions: Unlock button: disarm system Lock button: arm system Star button: re-exit function Light button: arm system in Stay/Instant mode Lock and unlock button: panic alarm Star and light button: medical alarm Star and Light button can also be programmed to trigger an output 97 / GE /
NX-475-I Panic pendant • • • • • • • • • •
Water resistant Not supervised Powered with 3.5V lithium battery Typical battery life: 5-8 years Transmission range 150m (open air) Water and shock resistant Can be worn around the neck Built-in clip allows sensor to be attached to belt or purse Allows to activate 24-hour alarm (police, medical, fire, ..) Color: white
NX-475-I
98 / GE /
NX-476-I Panic wrist watch • • • • • • • •
Water resistant Not supervised Powered with 3V lithium battery Typical battery life: 5-8 years Transmission range 120m (open air) Easy to use by elderly or disabled people Allows to activate 24-hour alarm (police, medical, fire, ..) Color: white
NX-476-I
99 / GE /
NX-480-I PIR Motion sensor • • • • •
• • • NX-480-I
•
Passive infrared sensor 11x12m Powered with two AA alkaline batteries Typical battery life: 3-4 years Transmission range 150m (open air) 3-minute transmitter lock out time after each detection (extends battery life) Walk test mode after tamper alarm Tamper switch Supervisory signal transmitter every 64 minutes Standard/high sensitivity setting
100 / GE /
NX-487-I Glass break sensor • • • • • • •
Detection radius up to 6 meters Based on Sentrol Shatterpro II technology Powered with two 3V lithium batteries Typical battery life: 3 years Transmission range 150m (open air) Tamper switch Supervisory signal transmitter every 64 minutes
NX-487-I
101 / GE /
60-885-43-EUR Shock sensor •
• • • • • 60-885-43-EUR
60-885-11-43-EUR
• •
Models available : • White (60-885-43-EUR) • Brown (60-885-11-43-EUR) Gross attack and pulse count detection modes Reed switch and magnet for detection of opening door/window Powered with 3.6V lithium battery Typical battery life: 5 years Transmission range 150m (open air) Tamper switch Supervisory signal transmitter every 64 minutes
102 / GE /
NX-491NT-I Optical smoke/heat sensor • • • • • • •
NX-491NTI
Photo-electric smoke sensor with built-in sounder and status LED Powered with two 3V lithium batteries Transmission range 150m (open air) Tamper switch Supervisory signal transmitter every 64 minutes Equipped with test button Heat sensor specs: • Integrated fixed temperature (57.2°C) • Integrated rate-of-rise heat detector (8.5°C / minute)
103 / GE /
Wireless 868 Mhz 104 / GE /
Wireless 868 Mhz • All NetworX panels can be wireless expanded by adding an additional wireless receiver • Two types of receivers (8 and 16 zones) are actually available depending on the application and type of control panel used, (32 zones version NX-832-I is pending) TM • Receiver can be mounted in the X-pand-A-Can enclosure with the control panel, or can be mounted in the NX-869 receiver enclosure • Up to four receivers can be used on a single NX8-EUR, up to 8 on the NX-8E
105 / GE /
Wireless 868 Mhz • Total bandwidth for security applications is 100KHz, while we are using 13KHz, • Diversity receiver using twin antennae Improved Signal Capture in a multi-path environment Signal Nulls and Voids Reduced
• Packetized Manchester Encoded Information
Frequency Shift Keyed (FSK) transmissions High Message Integrity Unique Address Each data packet has its own checksum
106 / GE /
NX-8xx-I Wireless receivers •
• • •
•
Models available • NX-808-I : 8 zones • NX-816-I : 16 zones Frequency 868 MHz, FM Received data integrity is 100% Supervision of all transmitters each 15 minutes (except keyfob and panic) Optional jamming detection (according to EN-50131)
NX-8xx-I
•
NX-869N : Enclosure for 868MHz wireless receivers
NX869N
107 / GE /
NX-85xN-I Door/window transmitters •
• • • • • NX-850N-I
• NX-851N-I
Models available • NX-850N-I : White • NX-851N-I : Brown Sends supervisory signal each 15 min. Powered with 3V Lithium battery Typical battery life: 3 years Additional input for NO or NC contact (not supervised) Transmission range 400m (open air), min. 20m indoor Dual tamper switch (opening housing and rip-off contact)
108 / GE /
NX-870-I 4-button keyfob • • • • •
NX-870-I
Not supervised (battery is supervised) Powered with 12V, 33mAh alkaline battery Typical battery life: 5-8 years Transmission range 150m (open air) Functions: Unlock button: disarm system Lock button: arm system Star button: re-exit function Light button: arm system in Stay/Instant mode Lock and unlock button: panic alarm (also low battery reset) Star and light button: medical alarm 109 / GE /
NX-881-I PIR Motion sensor • • • • • •
• • • NX-881-I
• •
Based on Sentrol Sharpshooter technology Passive infrared sensor 13m x 90° Powered with 3V Lithium battery Typical battery life: 3 years Transmission range 400m (open air) 2-minute transmitter lock out time after each detection (extends battery life) Walk test mode after tamper alarm Tamper switch Supervisory signal transmitter every 15 minutes Standard / double pulse setting Swivel bracket included
110 / GE /
NX-887-I Glass break sensor • • • • • • •
Detection radius up to 6 meters Based on Sentrol Shatterpro technology Powered with two 3V lithium batteries Typical battery life: 3 years Transmission range 400m (open air) Tamper switch Supervisory signal transmitter every 15 minutes
NX-887-I
111 / GE /
NX-891N-I Optical smoke/heat sensor •
• • • • • • NX-891N-I
Photo-electric smoke sensor with built-in sounder, dual thermo element and status LED Powered with two 3V lithium batteries Transmission range 400m (open air) Tamper switch Supervisory signal transmitter every 15 minutes Equipped with test button Heat sensor specs: • Integrated fixed temperature (57.2°C) • Integrated rate-of-rise heat detector (8.5°C / minute)
112 / GE /
NX-9008 -3 dB antennas • •
• •
NX-9008
Used during installation and test of the wireless transmitters Purpose is to ensure sufficient margin in signal strength during normal operation by reducing the receiver sensitivity during installation and maintenance checks -3dB means that receiver is over 50% less sensitive Transmitters strengths are visualized by means of the RSSI (Received Signal Strength Indication) value • Local via Keypads • Remotely via DL900 software
113 / GE /
NetworX
TM PinPoint :
A way to connect sensors on a 2-wire addressable bus
114 / GE /
PinPointTM addressable sensor bus
115 / GE /
PinPointTM addressable sensor bus Main characteristics: • • • • •
Based on Interlogix bus protocol “Sensors only” bus (no keypads and/or auxiliary modules) Full free topology Up to three loops of each 3000 meters Maximum 192 devices (on NX-8E), limitation is in control panel • Will be used in combination with Sentrol addressable sensors
116 / GE /
PinPointTM addressable sensor bus Addressable Two-Wire Point ID System: • PinPoint is the right choice for commercial or residential applications where extensive wire runs are needed to install traditional systems. • PinPoint can be wired in a free style configuration (Star, T-Tap or Single Loop) which give the user the flexibility on new or retrofit applications
117 / GE /
PinPointTM addressable sensor bus Flexibility: • PinPoint supports up to 192 total addressable devices on three separate loops of up to 3000 meters each • The system is scalable so it can adapt to changing customer requirements in the future
118 / GE /
PinPointTM addressable sensor bus • Accuracy: • PinPoint identifies the exact location or a trouble or an alarm event • Saves time for both emergency personnel and service technicians • PinPoint is a two wire system up to 50% fewer termination points and less chance of wiring errors
119 / GE /
PinPointTM addressable sensor bus Rewarding: • PinPoint installation require less wiring then traditional systems. • Less wire to pull means lower labor costs and greater profits on new and retrofit applications • PinPoint can be used by all existing Caddx dealers without the need to learn any new programming
120 / GE /
NX-2192E-EUR Bus interface
•
• • NX-2192E-EUR
•
Up to three loops of three kilometers means fast and easy installation for new construction or retrofit applications Supports up to 192 devices Addressable sensors indicate exact location of alarm or trouble event Advanced digital communication from the sensors to the panel
121 / GE /
SI-ID Single input device
•
•
• • •
The single input interface allows you to connect any single nonaddressable device to the bus Single or double end-of-line resistor configuration programmable Addressing done by dip switches Tamper switch Input can be assigned to any logical zone
SI-ID
122 / GE /
4I4O-ID 4-input/4-output device
•
• • • • • 4I4O-ID
•
4 input and 4 supervised output interface that allows you to connect up to 4 non-addressable devices Single or double end-of-line resistor configuration programmable Addressing done by dip switches Tamper switch Inputs can be assigned to any logical zone Additional inputs for low battery and mains fault available to supervise external power supply 500 mA maximum available on each individual output (supervised)
123 / GE /
AP750-ID PIR motion sensor
•
•
• •
AP750-ID
• •
Addressable 3D signal processing with gliding focus mirror optics analyzes size, speed, shape and adaptive alarm threshold Provides 7 separate curtain coverage patterns with 15,2 m range Flat wall or corner mounting with mounting height up to 3 m Ship with two plastic inserts, each covering half the coverage for more flexible mounting options (center curtain always active) Addressing done by dip switches Tamper switch 124 / GE /
5845-ID Glass break sensor
•
•
• 5845-ID
• • •
Sentrol ShatterPro’s Pattern Recognition TechnologyTM for superior detection and false alarm immunity Protects all glass types up to a standard thickness of 0.64 cm including plate, wired, tempered and laminated glass Senses through light blinds and unlined drape. Suitable for use in quite occupied areas on the perimeter loop Detection range up to 6 m diameter Addressing done by dip switches Tamper switch 125 / GE /
PinPointTM benefit summary • • • • • •
One interface module Up to 3 loops @ up to 3000 meters per loop Up to 192 devices on a single wire run Electrical isolation between loops Free style wiring Combination of Sentrol/ESL and Caddx/NetworX Technologies
127 / GE /
NetworX
TM VideoIQ
Lite NetworX intelligent video alarm verification
128 / GE /
We know it’s human Video IQTM lite Industry Challenge ‘Out of 750,000 call-outs, only 3% were true alarms’ Security Installer statistics
GE’s Solution A unique ‘On-Premise Video Alarm Verification Solution • PIRCAM provides verified discrimination between human intruders & false alarms • Embedded nature of Video IQTM provides an affordable solution with unrivalled stability • Communication options include supervised alarm & video transmission over GPRS and Ethernet 129 / GE /
We know it’s human Video IQTM lite Video IQ for CCTV applications …. • Video IQ is intelligent video motion detection which classifies the ‘cause of motion’ • It draws RED and YELLOW boxes around objects it recognizes, allowing differentiation between moving humans (RED) and moving objects (YELLOW) • Information is stored & processed on a stand-alone & centralized PC
130 / GE /
We know it’s human Video IQTM lite … Video IQ Lite for verified alarm • The compact version of Video IQ : - Lower Resolution: ¼ VGA (300.000 pixels) versus Full VGA - No Self Learn feature: Limited Human Detection Algorithm. Acceptable because PIR provides second method of detection - Indoor Use Only
131 / GE /
We know it’s human Video IQTM lite Human Motion
Video clip transmission
Internet / GPRS
132 / GE /
We know it’s human Video IQTM lite
PIRCAM
VVMIQ Module (CIB & VVM)
NetworX TM Panels
• Integrates CCTV functionality into the NetworX TM panel range • Sensor information combined with human recognition = verified alarm
133 / GE /
TM
Video IQ Lite System Setup : PIRCAM GPRS / Ethernet
OH Network Receiver
NX panel
Pircam
COM + 12V Det +12V Cam
Zone Input Video A
Video B
134 / GE /
TM
Video IQ Lite System Setup : PIRCAM
Armed
Disarmed
Cameras off when not fully Armed Privacy for Residential applications
135 / GE /
TM
Video IQ Lite System Setup : Camera Interface Board • Allows to connect up to 4 PIRCAM’s which represents up to 8 physical zones (4 PIR + 4 CAM) • Offers a Video output (3-pin connector) to connect a monitor for installation purposes (adjusting) • Offers separate power for PIR and CAM • Bus connectors for easy connection
136 / GE /
TM
Video IQ Lite System Setup : Video Verification Module • Analyses video signal using intelligent & unique algorithm for human detection (red and yellow boxes) • Creates video clips (ASF format) and adds event information in header • MPEG4 compression • Onboard Ethernet capabilities • Cinch-connector to view processed video
137 / GE /
TM
Video IQ Lite Video clips naming convention 2_0001_0001_000001_01_009_0_030106105249.asf Example A B C D E F G H A B C D E F G H
0= no motion* 1= motion* 2= human motion* receiver number line card number account code partition number zone/user number clip sequence number date & time stamp (MMDDYYHHMMSS)
* detected by camera
138 / GE /
TM
Video IQ Lite Integration with Automation • The OH2000E Net Rec software is provided as Java Classes • The OH 2000E Light can be integrated in any monitoring station software (so called Middleware) • The SDK is documented and can be provided • The Automation software keeps track of incoming alarms and video clip, and stores the video clips immediately in its database • The Automation Operator software shows the videoclips to the operator
139 / GE /
TM
Video IQ Lite Integration with Automation (MAS)
140 / GE /
TM
Video IQ Lite Integration with Automation (MAS) • Fully integrated with Mastermind over IP (no RS232 cabling) • Video-clips are stored on a mass storage device • Infinite number of video clips can be stored and retrieved • Video clips referenced by Mastermind • Simple click on 'camera' in event history, provides info about what happened 'in the past‘ • Operator is provided immediately with correct verification data, showing video clip with red/yellow boxes Mastermin OH NetRec
Wired
d
Panel
IP or GPRS
IP 141 / GE /
TM
Video IQ Lite Integration with Automation (MAS)
142 / GE /
TM
Video IQ Lite Programming NX-9104 • module number 65 • if GPRS is used for event reporting, the NX-7002 GSM/GPRS does no longer exist as a module NX-9104 module 65
NX-7002 module 78 module 65 : Ethernet - GPRS
• Will reboot at power up and exiting programming mode 143 / GE /
Video IQ Benefits • • • • • • • •
TM
Lite
Continuous analysis by Video-IQ algorithm On-Site verification reduces false alarms Reduces C.S. / Operator load On-Site verification will not miss an alarm 5-16 second clip with moving objects Pre-/Post alarm video clips available Supervised Camera connection Extended video clips for Lifesafety events(Fire, Panic, Medical, hold-up,…)
144 / GE /
NetworX
TM PremisesConnect
NetworX remote control/monitoring over internet 145 / GE /
What do we want to achieve ? IP/WiFi Camera X-10 Home Control
DSL Router NetworX TM Panel with IP module
Goal :
Data flow Network Connection
Internet User at a remote location
Give the customer the comfort to control / monitor his alarm system remotely 146 / GE /
What do we want to achieve ?
147 / GE /
Challenges • DHCP or Static IP • Patented HTTP Protocol usage, using Browser technique • Communication 3DES encrypted Data flow
NetworX TM
Network Connection
Panels
Internet
User at a remote location
Dynamic Address Security of the data from the panel
Security of the data from the user
• SSL Protection • No direct link into Alarm system • Valid Panel code required for Arming
148 / GE /
PremisesConnectTM Panel connected with the TCP/IP module to the internet (ex. Via ADSL) Dynamic matching of external IP Address Consumers can control their system via the internet with their Internet browser 24/7 & receive event notifications via e-mail
NetworX TM Panels Panel communication is encrypted, but port 80 (http) is used.
Internet
GE Server farm which delivers the user interface & Data of the panel the panel. Servers are located in a Datacenter and setup for loadbalancing and failover
149 / GE /
PremisesConnectTM
Virtual Dataflow
NetworX TM Panels Panel communication is encrypted, but port 80 (http) is used.
Network Connection
Internet
Deliver automatically 24/7 : • Actual status of the system • Infinite Panel history log • Get notification emails on selected events
150 / GE /
Summary – What do you need ? NX-Panel
Plus a valid PremisesConnectTM Account to register your panel
DSL/Cable Modem
Internet NX-590E All required software for the panel, to communicate with PremisesConnectTM is already build into the IP module !
151 / GE /
Technical highlights Communication via Internet is encrypted Arming/Disarming will require a valid panel user code for Arm/Disarm For using the PremisesConnectTM System, no additional Software required on the User side Strong IT Infrastructure in place to support the System Standard Port & Protocol used, to allow passing Firewalls
152 / GE /
Solution II - Service model Panel connected to the internet (ex. Via ADSL) Dynamic matching of external IP Address Virtual Connection Network Connection
Panel communication is encrypted, but port 80 (http) is used. Internet
API Software module
customer Server Environment Running : Web server Database server
Customer can use the API to develop PremisesConnectTM functionality in their own Internet Server environment. Local IT Expertise needed.
Consumers can control their system via the internet with their Internet browser 24/7 & receive event notifications via e-mail 153 / GE /
Technical Take-aways API Specific : Microsoft Enterprise Server 2003 required In-house IT Expertise to handle and implement it, required IT Infrastructure needs to be in place to support the System We provide a well documented API, enabling Customers to build customized applications to support emerging business models General : Communication from/to the panel via Internet is encrypted Arming/Disarming will require a valid panel user code for Arm/Disarm Standard Port & Protocol used, to allow passing Firewalls No ‘Port forwarding’ needed 154 / GE /
NetworX
Up/Downloader DL900
155 / GE /
DL900 – v2.19 Windows based software that supports programming of all NetworX control panels and accessories: • • • • •
Direct connect Dialup over PSTN phone line TCP/IP (Network) GSM (Data channel) GSM (TCP/IP over GPRS)
156 / GE /
DL900 – v2.19
Supports programming of all available panels: • NX-8E, NX-8-EUR, NX-6-EUR and NX-4-EUR
157 / GE /
DL900 – v2.19
Supports programming of all available modules (including new released modules
158 / GE /
NetworX
Accessories
159 / GE /
RES-CABLE-10 > Optional set of 10 NetworX bus cables > To connect new NX expanders with NX-x-EUR or NX-8E
160 / GE /
X-Pand-A-Can housings
•
NX-002 : Enclosure for NX-4
•
NX-003 : Enclosure for NX-6, NX-8 and NX-8E
•
NX-003CB : Commercial enclosure for NX-8 and NX-8E
•
NX-008 : Multi purpose housing for NetworX modules
NX-002 NX-003
NX-003CB
NX-008
161 / GE /
NetworX
Total solution
162 / GE /
NetworX Summary Keypad family
Virtual keypad
Wireless solutions
Premises ConnectTM Additional power supply
GSM/GPRS Solutions
Door control
TCP/IP Connectivity
VVMIQTM video verification
2-Way voice
PinPointTM adressable sensor bus
Voice speech module
Flexible zone expanders RS232 Connectivity
X-10
Output expanders 163 / GE /
End of presentation Questions ??