Minion. Central/2nd St. SW. 24. Super Mario. Central/3rd St. SW. 25. Leonardo (TMNT). 4th St. E/Central at Coffee Corner
scores are the best predictors of overall firefighter performance. The information ...... 27 Use relevant Fire Service computer programmes with ease (e.g. Microsoft.
Mar 15, 1997 - 6.2.1 The New York City domestic water supply system also supplies the ... hoselines an engine company mu
precast concrete lid will support a maximum 500 kg point load (pedestrian loading ... fitted options to increase treatme
are also available, making installation quick and easy. Approvals/ ... Extremely fast reacting and rapid sealing ... How
firefighter physical workload and fire suppression productivity under real fire conditions. ... o USDA Forest Service Technology and Development Centers,. Missoula .... Alexander (2003) made a call for greater efforts in the ergonomics / human.
and rural water product solutions. 2. 01. 6. | PRESSURE S. Y. S. TEMS | W4.23 H. Y d. R. O. TITE. 1 P. IECE. B. ALL. V.
Because of the specialised cavity design, the duo-fit is a popular repair option for leaking sockets & gibaults when
No need to empty the mains. Pipe cutting not required for repair. Low cost installation. No specialist tools required. P
developers and manufacturers of pipeline maintenance and testing equipment. Quality. ISO 9001:2008 Quality. Management S
Ductile iron Socket Fittings for Series 1 and Series 2 PVc Pipe. ... Product dimensions are nominal only, and should be
All Media Casting (Annalise Patterson), Andrea Kelland Casting, Annabel Lomas. Casting, Christina Asher Casting, Barefoo
available hydrants for flow tests so that the total length of the pipes with the increased flow ... consideration on placing hydrants may include many factors including accessibility, ... optimization are compared with the selection made by the exper
According to our Rules and Regula- tions for water use, the user is respon- sible for ensuring safe and efficient access
Mazur, A. (1998) A hazardous inquiry: the Rashomon effect at Love Canal, Cambridge: Harvard. University Press. Scarman Centre for the Study of Public Order.
and rural water product solutions. 2. 01. 6 ... All hydrants are assembled using 316 stainless steel fasteners. ... tAbl
NZ Underground Fire Hydrants
Scan for more information
Technical Guide W6.1
2016 | PRESSURE SYSTEMS | W6.1 NZ Underground Fire Hydrants
Gillies Fire Hydrants deliver high quality, durability and service to water authorities
Applications
Flow exceeds the NZS 4522 requirements
Quality
Water supply for Fire Service and
Minimal maintenance cost
ISO 9001:2008 Quality
similar operations
Management Standard
Approvals/Standards Product Attributes
NZS 4522.2010, superseding NZS/BS
Dependable New Zealand quality
750:1984
Patented AB Thrust Washer
AS/NZS 4020 approved for potable water and 4158 for coatings 316SS Fastenings
The go to organisation for civil and rural water product solutions
Gillies Fire Hydrants are derived from the renowned original Blakeborough Fire Hydrants – earning their reputation for delivering high quality, durability and service to water authorities and fire services throughout the world for well over a century. Design Specifications ■■
W6.1 NZ Underground Fire Hydrants | PRESSURE SYSTEMS | PG 2
■■
■■
■■
■■
■■
All hydrants are assembled using 316 stainless steel fasteners. All hydrants are supplied with double “O” ring spindle sealing, protected by a dirt seal as standard. The body/ bonnet and the body/outlet joints are also sealed using “O” Rings to ensure a long low maintenance life. The stopper sealing washer is made from high performance polyurethane – selected and tested for its performance and durability. The sealing washer is easily replaced without changing the whole stopper, keeping maintenance costs to a minimum. All hydrants are furnished with a 316 stainless steel outlet which has a machined sealing face, and a machine dressed BS round thread – reducing the wear to the female standpipe thread. Auto drains are available for all three hydrant types for frost protection.
Table 1 Products Available Hynds Code
Description
Standard
HSQNZ-C
Gillies Fire Hydrant Squat - without frost plug
NZS4522
HSQNZF-C
Gillies Fire Hydrant Squat - with frost plug
NZS4522
HMEDNZ-C
Gillies Fire Hydrant Medium - without frost plug
NZS4522
HMEDFNZ-C
Gillies Fire Hydrant Medium - with frost plug
NZS4522
HTALNZ-C
Gillies Fire Hydrant Tall - without frost plug
NZS4522
HTALNZF-C
Gillies Fire Hydrant Tall - with frost plug
NZS4522
130.0
120.0 Max allow able Head Loss 110.0
@25 l/sec NZ4522 (5.3)
100.0
kPa (Head Loss)
90.0
80.0
70.0
60.0
50.0
40.0 19.0
21.0
23.0
25.0
27.0
29.0
31.0
l/sec (Flow)
Table 2 Tall Hydrant
120.0 Max allow able Head Loss
110.0
@25 l/sec NZ4522 (5.3)
kPa (Head Loss)
100.0
90.0
80.0
70.0
60.0
50.0
40.0 19.0
21.0
23.0
25.0
27.0
29.0
31.0
l/sec (Flow)
Table 3 Squat Hydrant
130.0
120.0
Max allow able Head Loss @25 l/sec NZ4522 (5.3)
110.0
kPa (Head Loss)
100.0
90.0
80.0
70.0
60.0
50.0
40.0 19.0
21.0
23.0
25.0
27.0
l/sec (Flow)
Table 4 Medium Hydrant
29.0
31.0
W6.1 NZ Underground Fire Hydrants | PRESSURE SYSTEMS | PG 3
130.0
Tall Hydrant
Table 5 TALL HYDRANT PARTS LIST 1 2 29
3
26
25
24
22
23
4 6
5
7 8 9 6 21
10
7 (not visible)
12
20
(Optional) 13
19
14
Title
Qty
1
A HYDRANT SPINDLE NUT
1
2
AB DIRT SEAL
1
3
O RING
2
4
AB SEAL HOUSING
1
5
O RING
1
6
BOLT
7
7
WASHER
7
8
AB BONNET
1
9
O RING
1
10
AB HYD BRIDGE
1
11
A HYDRANT SPINDLE
1
12
AB STOPPER
1
13
AUTO DRAIN ASM
1
14
SPLIT PIN
1
15
ABM SEALING WASHER
1
16
ABM STOPPER RETAINING WASHER
1
17
BOLT
1
15
18
A BODY
1
16
19
O RING
1
20
NUT M12
4
21
ABM OUTLET
1
22
ABM DUST CAP
1
23
CHAIN HOOK
2
24
CHAIN
1
25
WASHER
2
26
BOLT
2
29
AB THRUST WASHER
1
17
18
Fig. 1
165
Part No: example. A-8 AB BONNET
387
40
W6.1 NZ Underground Fire Hydrants | PRESSURE SYSTEMS | PG 4
11
Part No.
(optional)
Fig. 2
Squat Hydrant
Table 6 SQUAT HYDRANT PARTS LIST Title
Qty
26
1
B HYDRANT SPINDLE NUT
1
25
2
AB DIRT SEAL
1
4
3
O RING
2
5
4
AB SEAL HOUSING
1
5
O RING
1
6
BOLT
7
7
WASHER
7
8
AB BONNET
1
9
O RING
1
10
AB HYD BRIDGE
1
11
B HYDRANT SPINDLE
1
15
12
AB STOPPER
1
(Optional) 13
13
AUTO DRAIN ASM
1
14
SPLIT PIN
1
15
ABM SEALING WASHER
1
16
ABM STOPPER RETAINING WASHER
1
17
BOLT
1
18
B BODY
1
19
O RING
1
20
NUT M12
4
21
ABM OUTLET
1
22
ABM DUST CAP
1
23
CHAIN HOOK
2
24
CHAIN
1
25
WASHER
2
26
BOLT
2
29
AB THRUST WASHER
1
2
29
3 6 7
24
23
8 9
22
10
6
11
21
12
7 (not visible)
14
20
16
19
17
18
Fig. 3
165
291
41
Part No: example.
Ø 32,39 (clearance) (optional)
Fig. 4
B-8
AB BONNET
W6.1 NZ Underground Fire Hydrants | PRESSURE SYSTEMS | PG 5
Part No.
1
Medium Hydrant
Table 7 MEDIUM HYDRANT PARTS LIST 28 27 2
6 7
Title
Qty
1
MED SPINDLE NUT
1
MED DIRT SEAL
1
3
26
2
4
25
3
O RING
2
4
MED SEAL HOUSING
1
5
O RING
1
6
BOLT
7
7
WASHER
7
8
MED BONNET
1
9
O RING
1
10
MED HYD BRIDGE
1
11
MED SPINDLE
1
12
MED STOPPER
1
13
AUTO DRAIN ASM
1
15
ABM SEALING WASHER
1
16
ABM STOPPER RETAINING WASHER
1
17
BOLT
1
18
MED HYD BODY
1
19
O RING
1
20
NUT M12
4
21
ABM OUTLET
1
22
ABM DUST CAP
1
23
CHAIN HOOK
2
24
CHAIN
1
25
WASHER
2
26
BOLT
2
27
SETSCREW
1
28
MED SPINDLE CAP
1
29
MED THRUST WASHER
1
5 29
8 9
24 23
10 22
11
6
1
21
12
15 (not visible) 7 16
20
17
19
18 13 (Optional)
Fig. 5
165
Part No: example.
365
120
W6.1 NZ Underground Fire Hydrants | PRESSURE SYSTEMS | PG 6
Part No.
Ø 25,4 Clearance (optional)
Fig. 6
MED-8 MED BONNET
W6.1 NZ Underground Fire Hydrants | PRESSURE SYSTEMS | PG 7
W6.1 NZ Underground Fire Hydrants | PRESSURE SYSTEMS | PG 8
Branches Nationwide Support Office & Technical Services 09 274 0316 Disclaimer: While every effort has been made to ensure that the information in this document is correct and accurate, users of Hynds product or information within this document must make their own assessment of suitability for their particular application. Product dimensions are nominal only, and should be verified if critical to a particular installation. No warranty is either expressed, implied, or statutory made by Hynds unless expressly stated in any sale and purchase agreement entered into between Hynds and the user.