•Up to 25 % less fuel consumption. ..... HONDA engines as well as with high-
performance synchronous generators. A sturdy monobloc .... ESE 206 HS-GT.
Type.
Power generators 2008 Product Catalog
ENDRESS Innovative energy of a strong brand In 94 years of existence, ENDRESS has specialized in the development, construction and sale of first-class power generators. With innovation and new products of technical excellence ENDRESS will set the trend and secure its leading position also in future. The mainstays of the corporate policy are: High performance and reliability due to the choice of outstanding components and standard quality; Environmental compatibility and future-proof technology through in-house development and production; ENDRESS know-how at the company's sites in Germany, Italy, France and Spain.
• • •
Innovative strength and customized product development as well as professional guidance in application are the parameters of a service-oriented corporate philosophy. In this way, ENDRESS meets the growing requirements and the internationalization of business also in future.
This makes ENDRESS so important to power generators: ENDRESS ENDRESS ENDRESS ENDRESS ENDRESS ENDRESS
is the leading brand for power generators in Europe. supplies products of all ratings and for all application classes. has passed all safety related tests and holds all awards. has a complete range of accessory items and services with guarantee. offers its partners free professional consultation on product application. maintains a closely knit network of service outlets.
Innovation from ENDRESS What you should know about generators Differences in consumers Types of protection
4-7 8 9
Explanations, specifications and what they mean
10
The Professional GT line 2.5 - 12 kVA
The ENDRESS generator profile
11
The Professional Plus GT line 4 - 12 kVA 19 - 20
16 - 18
The Silent product line 1.3 - 3.8 kVA
12 - 13
The Duplex line 3 - 13 kVA
21 - 24
The Classic Power line 1.6 - 2.9 kVA
14 - 15
The Silent Power line 5 - 12 kVA
25 - 27
The Diesel Line 3 - 11 kVA
28 - 29
TRIPLEX Technology
Emergency generators
• •
• Manual or automatic supply to the in-house network. Welding generators
• Modern petrol or diesel engines. • Robust and sturdy welding generators.
• • •
Brushless synchronous generator with electronic voltage regulation. Highest protection: IP 54. Maintenance-free for 20,000 generator hours, wear and maintenancefree due to inductive transmission.
• OHV engines from HONDA. Site generators
• DEUTZ oil/water cooled industrial engines. • Synchronous generators with electronic voltage regulation. Mobile floodlight systems
DUPLEX-G5 technology down the engine to the lowest possible • Slows speed in idle running. • Restart at full load from the beginning. • Substantial reduction of noise level in idle running. • Up to 25 % less fuel consumption.
Mobile generators
• Safe, reliable, long-lived. • Fully hot dip galvanized chassis, turn 360° degs. • Telescopic posts for mechanical or pneumatic extension. Power supply systems
• DEUTZ oil/water cooled industrial engines. • VOLVO-Penta water-cooled industrial engines.
• Extremely long-lived OHV engines. • Robust, long-lived diesel engines. generator equipment • Site-optimized with compound regulator – 400 V and higher.
3
Generators acc. to DIN 14685 3 - 15 kVA 30 - 35
PTO generators 12 - 55 kVA
46 - 47
Export product line 3.5 - 13 kVA
36 - 37
Engine pumps 600 - 1340 l/min
48 - 49
Emergency generators 6 - 13 kVA
38 - 43
Site generators 13 - 40 kVA
50 - 51
Mobile floodlight systems
52 - 53
Welding line generators 30 - 200 A
44 - 45
2008
Engine pumps DUPLEX-G4 technology
Product Catalog
• •
Corresponds to the VCSF (variable speed constant frequency) technology. Constant voltage and frequency, unrelated to the engine speed. Substantial reduction of pollution and noise emission. Very economical due to low cost of operation.
Power supply systems 15 - 600 kVA
54 - 64
Power supply systems Aid to selection Accessory items
65 66 - 68
Mobile generator Accessory items Aid to selection
69 70 - 71
TRIPLEX technology Generator communication Engine communication
ENDRESS
INNOVATION
Analysis of connected consumers
44 26
Made by ENDRESS a success story 1970
1980
1985
1990
Electric and engine welding units from 50 – 240 A
Permanently installed and mobile welding generators from 170 – 400 A
Permanently installed and noise-controlled large mobile units of 1500 rpm
Vertical generators from 1 – 3 kVA
Optimal efficiency
ENDRESS TRIPLEX technology
ENDRESS
Efficiency
• For global use • Conforms with VSCF (variable speed constant frequency) technology • Constant voltage and frequency - Unrelated to engine speed - The optimal efficiency of the engine is used • Substantial reduction of pollution and noise emission • Very economical due to low cost of operation
INNOVATION
ENDRESS TRIPLEX technology
55
Speed
Future-proof technology with in-house development and production ENDRESS is among the leading European suppliers of power generators. Decades of experience in the development and production of power generators ensure highest quality and absolute reliability. With an output range of up to 2000 kVA, ENDRESS supplies all needs. Innovative units for fire brigades, emergency management and rescue services or the supply of products bound to certain projects are part of the range, as are floodlight systems and emergency power generators.
1997
2000
2006
2007
Generators for fire brigades and emergency rescue services from 3 – 13 kVA
Duplex generators from 3 – 13 kVA
Silent generators from 6 – 10 kVA
Triplex technology from 5 – 30 kVA
DUPLEX-G4 generators Powerful tools and circular saws Light and lighting systems
M G
DUPLEX
VKS-Technologie = Verschleißfrei · Kontaktlos S törungsfrei
E
ENDRESS
INNOVATION
Site and waste sewage pumps
6 26
PE, inverter or electrode welding units
PC and computer processing systems
Miniature crane or cement machine
DUPLEX = more power from less volume! Powerful like a big unit: compact and handy like a 6 kV frame-mounted unit
Where large and heavy units used to work …
This is the Duplex difference: In the days where there was no electronics, an asynchronous generator was needed to be able to achieve “smooth” electricity and synchronous generators to tackle “heavy” electricity. With the DUPLEX technology, the electronic control module adapts to the drive engine and responds correspondingly
… today, DUPLEX technology proves its competence.
before the engine is overloaded. Hidden power reserves can be tapped and the DUPLEX generator “pushes up” even the heaviest inductive consumers and protects even sensitive consumers from damage. In this way all the advantages of asynchronous and synchronous alternators are combined in a single product, and the differences are not needed anymore.
The subtle difference Where conventional machines still have carbon brushes, which are subject to wear and tear, the ENDRESS DUPLEX system has an intelligent exciter machine. In combination with the power electronic assemblies, it marks the peak of modern power generation technology.
DUPLEX-G5 technology ENDRESS DUPLEX-G5 speed reduction by comparison
Full-load phase
Idle phase
LWA noise reduction
Points for the DUPLEX-G5 technology
• Slows down the engine to the lowest possible speed in idle running. • Restarts at full load from the beginning. • Substantial reduction of noise level in idle running. • Up to 25 % less fuel consumption. • Less emission of pollutants. • Life is extended several times over.
Full-load phase
Recovery phaseWaiting time (competitor)
mechanical/manual speed reduction
ENDRESS DUPLEX-G5 speed reduction
ENDRESS DUPLEX-G5 technology Competitor Recovery phase – Waiting time (competitor)
The new E-MSC 3.0 at a glance The perfect Multifunction Control System (MSC) from ENDRESS. A system for optimal safety and user friendliness for everyday use. CanBus capability included as standard.
Icon Run hours Function Total run hours of the engine/generator Display LED
P icon Load Function Phases 1-3 load Display LED Green = 0 to 80% Yellow = 81 to 100% Red = 101 to 110%
Option: CanBus linkup The link between the unit and the customer’s operator panel is provided by a control interface unit (CIU). Before data can be exchanged, some customization must be made at the ENDRESS factory.
Icon Ambient temperature1 Function Measures the direct ambient temperature Display LED Red = Ambient temperature too high
Icon Engine temperature1 Function Measures the engine temperature Display LED Red = Engine temperature too high
Icon Oil pressure Function Measures the oil pressure Display LED Red = Oil pressure fault
Icon Fuel temperature1 Function Measures the fuel temperature Display LED Red = Fuel temperature too high Icon Rotating field Function Status of the rotating field (cw or ccw) Display LED Red blinking = ccw rotation
Icon Emergency stop Function Emergency stop enabled Display LED Red = Emergency stop has been pressed
Icon Battery charge indicator Function Charge function of the alternator has failed Display LED Red = Fault
P icon Phase voltage Function Indicates voltage of phases 1-3 Display LEDs Red = high (undervoltage) Green = voltage OK Red = low (overvoltage)
Icon Iso3 Function Isolation fault Display LED Yellow = Half fault Red = Fault Icon Protective conductor check Function Protective conductor of the connected unit is checked Display LED Green = OK
Icon L1 = Phase 1 L2 = Phase 2 L3 = Phase 3 Icon Frequency Function Frequency of generated voltage Display LED Red = high (frequency too high) Yellow = 47 - 53 Hz (frequency OK) Red = low (frequency too low)
Icon Tank2 Function Level indication Display LED Green = Tank (full) Yellow = Tank (half full) Red = Tank (reserve)
1
2 3
Option - Warning signal package II (ambient, engine and fuel temperature functions only available as a set) Option - Fuel indicator, incl. fuel sensor ISO function only with fitted isometer
INNOVATION
r.p.m
phase uction d red Spee
Most generators do not run at constant load all the time but there are times of idling in between. Power is withdrawn as and when needed, such as when power tools are used. Today it is important to have power available on call.
ENDRESS
Why speed reduction?
7
What you should know about generators Verify prior to any start-up that the overall output of the unit to be connected does not exceed that of the nominal continuous output of the generator. The required information can be found on the nameplate or in the product booklet of the consumer.
GENERATORS
I N F O R M AT I O N
Types of engines Petrol engines should be considered when the mobile generator should be small and must only run for short periods at intermittent occasions. Diesel engines are heavier and more robust and therefore better for long run hours. Diesel engines have lower specific consumption.
When to use a high-speed and when a low-speed engine? The correct decision. High-speed engine (OHV petrol and diesel engines of 3000 rpm) Engines for daily operation of 4 - 10 hours. Life = service life between 3000 and 5000 hrs. (e.g., building sites, craft businesses)
•
Low-speed engines (diesel engines of 1500 rpm) Engines for round-the-clock service Life = service life between 10000 and 20000 hrs. (e.g., electricity and emergency generators)
•
Start-up system A distinction is generally made between two types of start-up systems: 1. Recoil starter to crank the engine manually via a strong pull of an automatic wind-up rope. 2. Electric starter via ignition.
At a glance Performance data often indicate the maximum output of the engine without load on the crankshaft = SAE HP, usually at 3600 rpm. For electrotechnical reasons all high-speed engines must run at 3000 rpm. Hence, the output is lower even if no load is connected. Therefore: Rely only on performance data that relate to 3000 rpm.
8
Rule of thumb: 1 HP engine output supplies maximum 0.5 kVA generator output (50%) 1 kW engine output supplies maximum 0.65 kVA generator output (65%)
Synchronous or asynchronous generators: The generator makes the difference. A system comparison.
Application
Synchronous
Asynchronous
All ohmic and inductive consumers.
Only ohmic consumers without restrictions. Inductive consumers with considerable restrictions.
Start up reaction
Unproblematic start up reaction, irrespective of the consumer. Problematic start up reaction with consumers which are difficult Compound regulatored alternators with 3 times the start up current. to start, particularly with alternators which do not have a Duplex alternators with 4 times the start up current. strengthened start up. A large generator is required for alternators with a strengthened start up.
Loading capacity
The alternator can also be loaded up to 100% by inductive consumers and can therefore be smaller.
The alternator can only be loaded up to 1/3 (without strengthened start up) and 2/3 (with strengthened start up) by inductive consumers.
Mechanical regulator IP23. Electronic regulator IP54.
Normally unregulated, capacitor.
Determined by internal cooler IP 23. Determined by external cooler IP 54.
Determined by the external cooler IP 54.
Regulator Type of protection
Protective measures Fuse disconnections as protection for user. RCD protection switch not necessary.
Fuse disconnections as protection for user. RCD protection switch not necessary.
Differences in consumers Ohmic consumers
Inductive consumers
In this case, the consumers concerned are machines which do not require any start up current, i.e., consumers whose power consumption does not increase up to the normal operating condition in the moment of ignition. Start-up current = operating current. The consumption data of these machines can be used without making any additions.
In this case, the consumers concerned are machines which require a multiplicity of power indicated only for a short time during the moment of starting.
*
GENERATORS
*
I N F O R M AT I O N
*
Particularly electric motors require 2-6 times the given value for the build up of the magnetic field as well as for the acceleration to the working speed.
*
* Universal motors which are mostly active power load consumers
9
Types of protection Why are they so important?
IP = International protection according to DIN 40050 60°
Electrical machines must be protected from moisture and dirt to be able to function properly. ENDRESS generators work to the protection measure/protection separation VDE 0100. The protection separation divides the supply line of a connected unit from the storing network. In this way a situation of a closed electric circuit can be prevented by the ground. Therefore the installation of grounding can be avoided.
The IP code is a two-digit number which indicates the type of protection. The first digit specifies the protection class for shock and ingress of solid foreign bodies, the second digit indicates the protection against water and moisture.
IP 23
IP 54
0 1 2 3 4 5
Unprotected Foreign bodies > 50 mm Foreign bodies > 12 mm Foreign bodies > 2.5 mm Foreign bodies > 2.5 mm Protected against dust
0 Unprotected 1 Vertical dripping 2 Dripping at up to 15° from vertical 3 Water spray at up to 60° from vertical 4 Splash water from all directions 5 Hose water from all directions
Explanations, Specifications and what they mean Explanation of the abbreviations in the tables
GENERATORS
I N F O R M AT I O N
V = Volts Hz = Hertz A = Ampere W = Watt (x 1000 = kW) VA = Volt x Amperes (x 1000 = kVA) Cos phi = Physical power factor
10 26
Voltage (230/400/115) Frequency (50/60) Amperage Active power Power factor Power factor (0.8 - 1)
Apparent power - indicated in units of VA or kVA This is the power the generator can produce. Active power - indicated in units of W or kW This is the power the generator can supply, depending on the generator's power factor. Reactive power This is the difference between active power and apparent power. It provides the required start-up current - moves between generator and consumer to build up the magnetic field.
Most ENDRESS generators comply with EC directive 2000/14/EC. Generators which do not comply with that directive are marked “Not for EC countries”.
Unit dB(A)
dB = Decibel (A) = Filter
COP = Continuous power of the unit Continuous power in full power application without a time limit. PRP = Variable continuous power of the unit Continuous power in a varying load operation (average 80% load within 24 hrs.) without time limit. LTP = Limited time unit power A maximum power which can be applied for a maximum of 500 hours per year, whereby in a variable load operation 300 hours should not be exceeded.
LP sound pressure level L = Level (measured value) P = Pressure LWA sound power level L = Level (measured value) W = Watt (power) A = Filter
RCD
Insulation monitoring
The RCD, also named grounding or short circuit switch, is one of the most widely used electrical safety elements that protects the user from electrically loaded components if he should accidentally touch them. The electricity supply will be automatically cut off as soon as there is a loss of power towards the ground wire, e.g. from a faulty conductor. Correct grounding, to which all earth conductors of the unit are connected, is a prerequisite for the perfect functioning of the RCD.
ENDRESS ISO makes a so-called “built grounding” unnecessary, whatever the bedding might be. Furthermore the “calibration” of this protective measure may be dispensed with. Hence operation becomes possible at any workplace without any further preparations. In addition high resistance insulation defects are reliably detected and automatically cause the voltage to be switched off.
ENDRESS type code
ESE 504 SDYS-GT ES ISO DIN Diesel Silent = = = = =
with silencer acc. to DIN 14658 insulation monitored electric starting large tank
S = Synchronous generator IP 23 T = TRIPLEX G = DUPLEX G4/G5 IP54 Y = YANMAR D = B = BRIGGS & STRATTON V = H = HONDA petrol R = HATZ diesel D = 3-phase current 400 V 3 ph. S = Welding generator 2 = Base frame 4 = Frame unit 6 = Large tank 8 = Noise cover = Output rating = ENDRESS GENERATOR
DEUTZ VOLVO RUGGERINI AC
E
M
TRIPLEX
G
Synchronous generator
Duplex-G4 generator
Triplex technology
• • • • •
• • • • • •
with VSCF technology. • Conforms voltage and frequency unrelated to • Constant engine speed. reduction of pollution and noise • Substantial emission. economical due to low cost of operation. • Very • Smaller and with higher output.
Class of protection IP 23 against water spray. Maintenance-free. Can withstand start-up current for a short time. Compound-controlled high-performance generator suitable for 3 times overload from 400 V. Smooth voltage shape.
Brushless synchronous generator IP 54, with electronic voltage regulation. Start-up performance 60% higher than conventional generators. 100% constant voltage in spite of varying speed. Suitable for 200% load unbalance. 20000 generator hours. VKS technology.
GENERATOR PROFILE
M G
G
E
Duplex-G5 technology down the engine to the lowest possible • Slows speed in idle running. at full load from the beginning. • Restarts reduction of noise level in idle run• Substantial ning. • Up to 25 % less fuel consumption.
ENDRESS
M
DUPLEX
The ENDRESS generator profile
11 Engine or diesel. • Petrol starting by recoil starter. • Easy OHV design. • Modern Less petrol consumption. Less oil consumption.
oil cutoff. • Low transistor ignition. • Contactless • Simple handling.
Monobloc tube frame protection of engine and transmission. • Optimal 4 fold-out • Tool box. carrying handles. • Strong steel tube. •
Bearings in vibration absorbing Silent block • Supported bearings. Socket outlets water protected socket outlets • Splash with neutral conductor. socket outlet for 230 V. • CEE • CEE socket outlet for 400 V, 5-pin.
SILENT-LINE
G E N E R AT O R S
Silent Line generators 1.3 - 3.8 kVA
12
The concept of the future in the mobile generator market: compact, lightweight, low noise, powerful…
…and suitable for all applications. Most advanced generator technology supplies highest output and current whose quality compares to that of the public mains. The intelligent engine management controls the engine speed as function of the load which reduces fuel consumption and noise. Constant power output is a particular advantage for electronic consumers and consumers with start-up current.
• TRIPLEX technology. • Intelligent engine management. • Constant power output. • Stable and exact parameters. • Low-noise and economical. • Easy starting with most advanced • • • •
engine technology. Light-weight and compact. Long service life. Simple and safe to handle. Complies with all norms.
Mobile power generation on highest level. For boats, camping and events, high cost effectiveness.
SILENT-LINE
G E N E R AT O R S
ESE 3500 T Silent
ESE 4500 T Silent
E
ESE 2000 T Silent
M Type
ESE 2000 T Silent
ESE 3500 T Silent
ESE 4500 T Silent
Order No.
110 000
110 001
110 002
Alternator
synchronous
synchronous
synchronous
Max. output [LTP] kVA/kW
1,65/1,65
3,2/3,2
4,3/4,3
Constant rating [COP] kVA/kW
1,35/1,35
2,8/2,8
3,8/3,8
Nominal voltage
230 V 1~/12 V =
230 V 1~/12 V =
230 V 1~/12 V =
Nominal current/cos (phi)
5,8 A 1~/8,3 A =/1
12,1 A 1~/8,3 A =/1
16,5 A 1~/8,3 A =/1
Frequency/Type of protection
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
Voltage regulation
electronic
electronic
electronic
Engine type
ROBIN EH09
ROBIN EX21
ROBIN EX27
Version
1-cyl. 4-stroke OHV
1-cyl. 4-stroke
1-cyl. 4-stroke
Engine capacity
86 cm3
212 cm3
265 cm3
Max. output
2,1 kW/2,9 HP
5,1 kW/7 HP
6,6 kW/9 HP
Fuel/Tank capacity (litres)
Unleaded petrol/4
Unleaded petrol/10,8
Unleaded petrol/12,8
Consumption/Running-time1
0,7 l/6 h
1,4 l/6,5 h
1,8 l/7 h
Start-up system
Recoil
E-start incl. battery
E-start incl. battery
Sound power level LWA2
90 dB(A)
91 dB(A)
91 dB(A)
Sound pressure level LPA3
65 dB(A)
66 dB(A)
66 dB(A)
Weight kg
21
59
74
Dimensions L x W x H in mm
490 x 295 x 445
537 x 482 x 583
580 x 527 x 618
Outfit Shockproof sockets
2 x 230 V/16 A
2 x 230 V/16 A
2 x 230 V/16 A
Operating control lamps
Digital display
Digital display
Cut-off when lack of oil, load-dependent engine speed, overload protection, connection for 12 V battery charge
Application areas*
230 V
230 V
230 V
Appliances up to
1350 W
2800 W
3800 W
PC/Multimedia up to
1350 W
2800 W
3800 W
Electric tools up to
1200 W
2600 W
3600 W
Gardening equipment up to
1000 W
1900 W
2500 W
1400 W
1900 W
Construction equipment up to 1 2
*
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table.
TRIPLEX
G
13
G E N E R AT O R S
CLASSIC POWER-LINE
Classic Power Line generators 1.6 - 2.9 kVA
14 18 26 ESE 30 BS
All-round generators for electrical equipment, power tools, gardening equipment and lighting.
The portable ENDRESS generators of this type series are equipped with HONDA engines as well as with high-performance synchronous generators. A sturdy monobloc tube frame with large side panels protects engine and generator (except ESE 20 BS). Low oil cut-off and overload protection belong to standard outfit.
G E N E R AT O R S
ESE 20 BS
CLASSIC POWER-LINE
Classic Power-Line quality generators, which convince in performance and price.
ESE 3000 ESE 40 BS Available accessories Set of wheels
Order No. 161 000
Type
ESE 20 BS
ESE 30 BS
ESE 35 BS
ESE 40 BS
Order No.
230 001
45 900-P
230 004
45 9800-FP
210 002
Alternator
synchronous
synchronous
synchronous
synchronous
synchronous
Max. output [LTP] kVA/kW
15
except for ESE 20 BS, ESE 3000
ESE 3000
2,1/1,9
2,5/2,2
3,0/2,7
3,4/3,1
2,8/2,6
Constant rating [COP] kVA/kW 1,6/1,5
2,0/1,8
2,4/2,1
2,9/2,6
2,4/2,2
Nominal voltage
230 V 1~
230 V 1~
230 V 1~
230 V 1~
230 V 1~/12 V
Nominal current
6,5 A 1~/0,9
8,7 A 1~/0,9
10,3 A 1~/0,9
12,5 A 1~/0,9
10,4 A 1~/10 A =/0,9
Frequency/Type of protection 50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
Engine type
HONDA GC 135
HONDA GC 160
HONDA GC 190
HONDA GX 200
HONDA GX 160
Version
1-cyl. 4-stroke
1-cyl. 4-stroke
1-cyl. 4-stroke
1-cyl. 4-stroke OHV
1-cyl. 4-stroke OHV
Engine capacity
135 cm3
160 cm3
187 cm3
196 cm3
163 cm3
Max. output
2,7 kW/3,7 HP
3,2 kW/4,4 HP
4,4 kW/5,9 HP
4,3 kW/5,8 HP
3,6 kW/4,9 HP
Fuel/Tank capacity (litres)
Unleaded petrol/1,7
Unleaded petrol/2
Unleaded petrol/2
Unleaded petrol/11
Unleaded petrol/11
Consumption/Running-time1
0,7 l/2,5 h
0,8 l/2,5 h
1 l/2 h
1,1 l/10 h
0,9 l/12 h
Start-up system
Recoil
Recoil
Recoil
Recoil
Recoil
Sound power level LWA2
94 dB(A)
95 dB(A)
96 dB(A)
96 dB(A)
93 dB(A)
Sound pressure level LPA3
69 dB(A)
70 dB(A)
71 dB(A)
71 dB(A)
68 dB(A)
Weight kg
20
33
34
42
43
Dimensions L x W x H in mm
492 x 355 x 390
640 x 455 x 400
640 x 455 x 400
620 x 405 x 500
620 x 405 x 400
2 x 230 V/16 A
2 x 230 V/16 A
2 x 230 V/16 A
2 x 230 V/16 A 230 V
Outfit Shockproof sockets
1 x 230 V/16 A
Cut-off when lack of oil, overload protection Application areas*
230 V
230 V
230 V
230 V
Electric tools up to
1400 W
1700 W
2000 W
2500 W
2100 W
Construction equipment up to
1000 W
1200 W
1400 W
1700 W
1500 W
1000 W
1300 W
1100 W
Compressors or pumps up to 1 2
*
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table.
G E N E R AT O R S
PROFESSIONAL-GT-LINE
Professional GT Line generators 2.5 - 7 kVA
16
Type
ESE 206 HS-GT
Order No.
112 000
112 011
Alternator
synchronous
synchronous
Max. output [LTP] kVA/kW
2,9/2,6
Constant rating [COP] kVA/kW 2,45/2,2
ESE 206 HS-GT
• HONDA OHV engines. • Compound regulator at 400 V. • Thermo protection switch. • Low oil cut-off. • Robust monobloc tube frame. • 11-18 liter tank for long run hours.
3,4/3,1 2,9/2,6
Nominal voltage
230 V 1~
230 V 1~
Nominal current
10,6 A 1~
12,5 A 1~
Power factor cos (phi)
0,9
0,9
Frequency/Type of protection 50 Hz/IP 23
50 Hz/IP 23
Engine type
HONDA GX 160
HONDA GX 200
Engine version
1-cyl. 4-stroke OHV
1-cyl. 4-stroke OHV
Engine capacity
163 cm3
196 cm3
Max. output
3,6 kW/4,9 HP
4,3 kW/5,8 HP
Fuel/Tank capacity (litres)
Unleaded petrol/11
Unleaded petrol/11
Running-time at ¾ load approx.1
The Professional GT Line excels in the high standard of quality, reliability and long service life.
ESE 306 HS-GT
0,9 l/12 h
Start-up system
Recoil
Recoil
Sound power level LWA2
96 dB(A)
96 dB(A)
Sound pressure level LPA3
71 dB(A)
71 dB(A)
Weight kg
42
44
Dimensions L x W x H in mm
623 x 409 x 500
623 x 409 x 500
Outfit
2 x 230 V/16 A
2 x 230 V/16 A
Shockproof sockets Cut-off when lack of oil, overload protection Application areas*
230 V
230 V
Electric tools up to
2100 W
2500 W
Construction equipment up to
1500 W
1700 W
1300 W
1300 W
Inverter welding machines up to Compressors, pumps up to 1 2
*
Consumption/litres in hours, running-time in hours. These indications are based on approx. values Sound level indication according to the directive for noise emission law 2000/14/EG. As the power needs of each consumer are influenced by various factors, no claims can be derived
For demanding users. Mature technology and solid construction: the Professional GT line
G E N E R AT O R S
PROFESSIONAL-GT-LINE
ESE 606 HS-GT
ESE 506 DHS-GT
Options Set of wheels Crane loading device
Order No. 161 000
all types
161 103
except for ESE 206 HS-GT, ESE 306 HS-GT
carrying handles, fold-out (4 pcs.) 161 002
all types
ESE 406 HS-GT
ESE 506 DHS-GT
ESE 406 HS-GT ES
ESE 606 HS-GT
ESE 606 DHS-GT
ESE 606 DHS-GT
ESE 606 DHS-GT ES
112 001
112 009
112 003
112 002
112 004
112 008
synchronous
synchronous
synchronous
synchronous
synchronous
synchronous
5,1/4,6
5,1/4,6
6,3/5,0
4,2/3,7
7,2/6,4
8,3/6,6
5,5/4,9
8,3/6,6
5,5/4,9
4,2/3,9
4,2/3,9
5,4/4,3
3,1/2,8
6,0/5,4
7,0/5,6
4,1/3,7
7,0/5,6
4,1/3,7
230 V 1~
230 V 1~
400 V 3~
230 V 1~
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1~
18,3 A 1~
18,3 A 1~
7,7 A 3~
13,5 A 1~
26,1 A 1~
10,1 A 3~
17,8 A 1~
10,1 A 3~
17,8 A 1~
0,9
0,9
0,8
0,9
0,9
0,8
0,9
0,8
0,9
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
HONDA GX 270
HONDA GX 270
HONDA GX 270
HONDA GX 390
HONDA GX 390
HONDA GX 390
1-cyl. 4-stroke OHV
1-cyl. 4-stroke OHV
1-cyl. 4-stroke OHV
1-cyl. 4-stroke OHV
1-cyl. 4-stroke OHV
1-cyl. 4-stroke OHV
270 cm3
270 cm3
270 cm3
389 cm3
389 cm3
389 cm3
6,3 kW/8,6 HP
6,3 kW/8,6 HP
6,3 kW/8,6 HP
8,3 kW/11,3 HP
8,3 kW/11,3 HP
8,3 kW/11,3 HP
Unleaded petrol/18
Unleaded petrol/18
Unleaded petrol/18
Unleaded petrol/18
Unleaded petrol/18
Unleaded petrol/18
1,1 l/10 h
1,6 l/11 h
1,6 l/11 h
Recoil
E-start incl. battery
Recoil
Recoil
Recoil
E-start incl. battery
97 dB(A)
97 dB(A)
97 dB(A)
97 dB(A)
97 dB(A)
97 dB(A)
72 dB(A)
72 dB(A)
72 dB(A)
72 dB(A)
72 dB(A)
72 dB(A)
62
66
76
74
82
90
832 x 513 x 570
832 x 513 x 570
832 x 513 x 570
832 x 513 x 570
832 x 513 x 570
832 x 513 x 570
2 x 230 V/16 A
2 x 230 V/16 A
1 x 230 V/16 A
1 x 230 V/16 A
1 x 230 V/16 A
1 x 230 V/16 A
1 x CEE 400 V/16 A
1 x CEE 230 V/32 A
1 x CEE 400 V/16 A
1 x CEE400 V/16 A
1,6 l/11 h
2,2 l/8 h
2,1 l/8,5 h
2,1 l/8,5 h
230 V
230 V
400 V
230 V
230 V
400 V
230 V
400 V
230 V
3800 W
3800 W
4200 W
2700 W
5300 W
5500 W
3600 W
5500 W
3600 W
2600 W
2600 W
2900 W
1900 W
3600 W
3700 W
2500 W
3700 W
2500 W
2,5 mm 2000 W at ¾ load and therefore without obligation. 3 Sound pressure level at distance of 7 m. from this table.
2000 W
2200 W
3,25 mm 1400 W
2800 W
2800 W
3,25 mm 1900 W
2800 W
1900 W
17
G E N E R AT O R S
PROFESSIONAL-GT-LINE
Professional GT Line generators 10 - 12 kVA These “power packs” provide maximum performance and reliability. Compact design and best craftsmanship for harsh professional duty.
• HONDA 2-cylinder OHV engines. • B & S V-Twin 2-cylinder OHV engines. • Thermo protection switch. • Low oil cut-off. • High-performance synchronous generators. • Robust monobloc tube frame with side panels • •
Available accessories Set of wheels Set of wheels Crane loading device
Order No. 161 000 161 007 161 104
for type series ESE 1006 for type series ESE 1206 for type series ESE 1206
NEW
18
for perfect dust and weather protection. 16 - 24 liter tank for long run hours. Compound regulator at 400 V.
NEW
Type
ESE 1006 DBS-GT
ESE 1006 DBS-GT ES
ESE 1206 HS-GT ES
Order No.
112 023
112 024
112 021
ESE 1206 DHS-GT ES 112 022
Alternator
synchronous
synchronous
synchronous
synchronous
Max. output [LTP] kVA/kW
11,0/8,8
6,6/5,9
11,0/8,8
6,6/5,9
11,9/10,7
13,9/11,1
9,2/8,3
Constant rating [COP] kVA/kW 10,0/8,0
6,0/5,4
10,0/8,0
6,0/5,4
10,0/9,1
11,8/9,4
6,9/6,2
Nominal voltage
400 V 3~
230 V 1~
400 V 3~
230 V 1~
230 V 1~
400 V 3~
230 V 1~
Nominal current
14,4 A 3~
26,0 A 1~
14,5 A 3~
26,1 A 1~
43,5 A 1~
17 A 3~
30 A 1~
Power factors cos (phi)
0,8
0,9
0,8
0,9
0,9
0,9
0,8
Frequency/Type of protection 50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
Engine type
B & S V-Twin
B & S V-Twin
HONDA GX 620
HONDA GX 620
Engine version
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
Engine capacity
570 cm3
570 cm3
614 cm3
614 cm3
Max. output
12,0 kW/16,3 HP
12,0 kW/16,3 HP
13,5 kW/18,4 HP
13,5 kW/18,4 HP
Fuel/Tank capacity (litres)
Unleaded petrol/16
Unleaded petrol/16
Unleaded petrol/24
Unleaded petrol/24
Running-time at ¾ load approx.1 2,9 l/5 h
2,9 l/5 h
3,5 l/7 h
3,5 l/7 h
Start-up system
Recoil
E-start incl. battery
E-start incl. battery
E-start incl. battery
Sound power level LWA2
97 dB(A)
97 dB(A)
96 dB(A)
96 dB(A)
Sound pressure level LPA3
72 dB(A)
72 dB(A)
71 dB(A)
71 dB(A)
Weight kg
110
115
170
175
Dimensions L x W x H in mm
945 x 570 x 640
945 x 570 x 640
960 x 638 x 664
960 x 638 x 664
Outfit
2 x 230 V/16 A
2 x 230 V/16 A
1 x 230 V/16 A
1 x 230 V/16 A
Shockproof sockets
1 x CEE 400 V/16 A
1 x CEE 400 V/16 A
1 x CEE 230 V/16 A
2 x CEE 230 V/16 A
Handles, fold-out
Handles, fold-out
1 x CEE 230 V/32 A
1 x CEE 400 V/16 A
Cut-off when lack of oil, overload protection Application areas*
400 V
230 V
400 V
230 V
230 V
400 V
Electric tools up to
7900 W
5300 W
7900 W
5300 W
9000 W
9300 W
6100 W
Construction equipment up to
5300 W
3600 W
5300 W
3600 W
6000 W
6200 W
4100 W
2500 W
3700 W
2500 W
4500 W
4700 W
Inverter welding sets up to
4,5 mm
Compressors or pumps up to
3700 W
1 2
*
4,5 mm
230 V
5,0 mm
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table.
3100 W
G E N E R AT O R S
PROFESSIONAL-GT-LINE
Professional Plus GT Line generators 4 - 5.4 kVA
High-quality design plus extra outfit are typical of this series.
Points for the Professional Plus GT line: Isometer. Voltmeter. Run hour meter. Large tank. Thermal overload protection. HONDA OHV engines. Compound regulator at 400 V.
• • • • • • •
Type
ESE 506 HS-GT ES ISO
ESE 506 DHS-GT ES ISO
Order No.
112 013
112 006
Alternator
synchronous
synchronous
Max. output [LTP] kVA/kW
5,3/4,8
6,3/5,0
4,2/3,7
Constant rating [COP] kVA/kW 4,1/3,7
5,4/4,3
3,1/2,8
Nominal voltage
230 V 1~
400 V 3~
230 V 1~
Nominal current
17,8 A 1~
7,7 A 3~
13,5 A 1~
Power factor cos (phi)
0,9
0,8
0,9
Frequency/Type of protection 50 Hz/IP 23
50 Hz/IP 23
Engine type
HONDA GX 270
HONDA GX 270
Version
1-cyl. 4-stroke OHV
1-cyl. 4-stroke OHV
Engine capacity
270 cm3
270 cm3
Max. output
6,3 kW/8,6 HP
6,3 kW/8,6 HP
Fuel/Tank capacity (litres)
Unleaded petrol/18
Unleaded petrol/18
Consumption/Running-time1
1,6 l/11 h
1,6 l/11 h
Start-up system
E-start incl. battery
E-start incl. battery
Sound power level LWA2
97 dB(A)
97 dB(A)
Sound pressure level LPA3
72 dB(A)
72 dB(A)
Weight kg
79
88
Dimensions L x W x H in mm
832 x 513 x 570
832 x 513 x 570
Outfit
1 x 230 V/16 A
1 x 230 V/16 A
1 x CEE 230 V/32 A
1 x CEE 400 V/16 A
Shockproof sockets
Cut-off when lack of oil, overload protection, voltmeter, operating hour meter, isometer Application areas*
230 V
400 V
230 V
Electric tools up to
3600 W
4200 W
2700 W
Construction equipment up to
2400 W
2900 W
1900 W
Inverter welding up to Compressors or pumps up to 1 2
*
2,5 mm 1900 W
2200 W
1400 W
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table.
19
PROFESSIONAL-PLUS-GT-LINE
G E N E R AT O R S
20
Professional Plus GT Line generators 6 - 12 kVA Note on insulation monitoring: The insulation monitoring is a major contribution to improving electrical safety and makes the application of this unit possible in damp places such as ducts and shafts, and in areas in which suitable grounding for the generator cannot be produced. The isometer provides highest safety during electric fault and stops the voltage supply instantly.
Made for harsh professional duty.
ESE 606 DHS-GT ES ISO
Available accessories Set of wheels Set of wheels Crane loading device Crane loading device
Order No. 161 000 161 007 161 103 163 104
for for for for
type type type type
series series series series
ESE ESE ESE ESE
506, ESE 606 1206 506, ESE 606 1206
ESE 1206 HS-GT ES ISO
Type
ESE 606 HS-GT ES ISO
ESE 606 DHS-GT ES ISO
ESE 1206 HS-GT ES ISO
ESE 1206 DHS-GT ES ISO
Order No.
112 019
112 007
112 016
112 017
Alternator
synchronous
synchronous
synchronous
synchronous
Max. output [LTP] kVA/kW
7,1/6,4
8,3/6,6
5,5/4,9
11,9/10,7
13,9/11,1
9,2/8,3
Constant rating [COP] kVA/kW 6,0/5,4
7,0/5,6
4,1/3,7
10,0/9,1
11,8/9,4
6,9/6,2
Nominal voltage
230 V 1~
400 V 3~
230 V 1~
230 V 1~
400 V 3~
230 V 1~
Nominal current
26,1 A 1~
10,1 A 3~
17,8 A 1~
43,5 A 1~
17 A 3~
30 A 1~
Power factor cos (phi)
0,9
0,8
0,9
0,9
0,9
0,8
Frequency/Type of protection 50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
Engine type
HONDA GX 390
HONDA GX 390
HONDA GX 620
HONDA GX 620
Version
1-cyl. 4-stroke OHV
1-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
Engine capacity
389 cm3
389 cm3
614 cm3
614 cm3
Max. output
8,3 kW/11,3 HP
8,3 kW/11,3 HP
13,5 kW/18,4 HP
13,5 kW/18,4 HP
Fuel/Tank capacity (litres)
Unleaded petrol/18
Unleaded petrol/18
Unleaded petrol/24
Unleaded petrol/24
Consumption/Running-time1
2,1 l/8,5 h
2,1 l/8,5 h
3,5 l/7 h
3,5 l/7 h
Start-up system
E-start incl. battery
E-start incl. battery
E-start incl. battery
E-start incl. battery
Sound power level LWA2
97 dB(A)
97 dB(A)
96 dB(A)
96 dB(A)
Sound pressure level LPA3
72 dB(A)
72 dB(A)
71 dB(A)
71 dB(A)
Weight kg
91
96
170
176
Dimensions L x W x H in mm
832 x 513 x 570
832 x 513 x 570
960 x 638 x 664
960 x 638 x 664
Outfit
1 x 230 V/16 A
1 x 230 V/16 A
1 x 230 V/16 A
1 x 230 V/16 A
Shockproof sockets
1 x CEE230 V/32 A
1 x CEE 400 V/16 A
1 x CEE 230 V/16 A
2 x CEE 230 V/16 A
1 x CEE 230 V/32 A
1 x CEE 400 V/16 A
Cut-off when lack of oil, overload protection, voltmeter, operating hour meter, isometer Application areas*
230 V
400 V
230 V
230 V
400 V
Electric tools up to
5300 W
5500 W
3600 W
9000 W
9300 W
6100 W
Construction equipment up to
3600 W
3700 W
2500 W
6000 W
6200 W
4100 W
1900 W
4500 W
Inverter welding machines up to
3,25 mm
Compressors or pumps up to
2800 W
1 2
*
2800 W
230 V
5,0 mm
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table.
4700 W
3100 W
Duplex Line generators 3 - 13 kVA Where large and heavy units used to work, today DUPLEX technology proves its competence.
• PE and inverter welding units. • Electrode welding units. • PC and computer processing systems. • Lights and lighting systems. • Complete power delivery in three • •
phase and alternating current with different consumers. Powerful electric tools as well as pumps and circular saws. Miniature cranes, cement machine.
STOP! One generator for all applications!
Why lower speed? Most generators do not run at constant load all the time but there are times of idling in between. Power is withdrawn as and when needed, such as when power tools are used. Today it is important to have power available on call.
Points for the DUPLEXS-G5 technology
• Slows down the engine to the lowest possible speed in idle running. • Restarts at full load from the beginning. • Substantial reduction of noise level in idle running. • Up to 25 % less fuel consumption. • Less emission of pollutants. • Life is extended several times over.
DUPLEX-LINE
Due to its advantages, the brushless synchronous generator IP 54 (4-fold starting current) can pick up the load peaks of individual consumers, such as electric machines which are difficult to start up (cement machines), and at the same time operate electronic consumers (PE welding unit).
G E N E R AT O R S
Exemplary and trend-setting in quality, technology and outfit.
21
Duplex Line generators
DUPLEX-LINE
G E N E R AT O R S
Modern and more powerful consumers need more output from mobile generators. The development of such units is governed by customer and market demands. Therefore, we constantly add new versions to our product lines. The new DUPLEX generators set new standards in precision and reliability.
• Optimal operating comfort with new • •
ESE 604 DHG DUPLEX ESE 304 HG DUPLEX
• Available accessories Set of wheels Set of wheels Crane loading device Refuelling system Exhaust pipe
Order No. 161 000 161 015 E 130 265 163 110 163 120
for for for for for
ESE ESE ESE ESE ESE
control panel. Larger tank for longer run time - 20 liters. New place for the tank for less heating, less sensitive to temperature. Improved tank opening, higher filler neck.
604 DHG, ESE 604 DHG ES Diesel 606, ESE 1006, ESE 1306 DBG ES Duplex 604 DHG, ESE 604 DHG ES Diesel 606, ESE 1006, ESE 1306 DBG ES Duplex 606, ESE 1006, ESE 1306 DBG ES Duplex
NEW
22
NEW
Type
ESE 304 HG Duplex
ESE 604 DHG Duplex
ESE 606 DBG Duplex
Order No.
113 012
113 000
113 002
113 003
Alternator/Duplex-G4
synchronous
synchronous
synchronous
synchronous
Max. output [LTP] kVA/kW
3,3/2,6
6,6/5,3
4,4/4,0
6,6/5,3
4,4/4,0
6,6/5,3
4,4/4,0
Constant rating [COP] kVA/kW
3,0/2,4
6,0/4,8
4,0/3,6
6,0/4,8
4,0/3,6
6,0/4,8
4,0/3,6
Nominal voltage
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1~
Nominal current
13 A 1~
8,7 A 3~
18,0 A 1~
8,7 A 3~
18,0 A 1~
8,7 A 3~
18,0 A 1~
Power factor cos (phi)
0,9
0,8
0,9
0,8
0,9
0,8
0,9
Frequency/Type of protection
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
Voltage regulation
electronic
electronic
electronic
electronic
Engine type
HONDA GX 200
HONDA GX 390
B & S V-Twin
B & S V-Twin
Version
1-cyl. 4-stroke OHV
1-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
Engine capacity
196 cm3
389 cm3
480 cm3
480 cm3
Max. output [LTP] kVA/kW
4,3 kW/5,8 HP
8,3 kW/11,3 HP
7,5 kW/10,2 HP
7,5 kW/10,2 HP
Fuel/Tank capacity (litres)
Unleaded petrol/3,6
Unleaded petrol/6,5
Unleaded petrol/20
Unleaded petrol/20
Consumption/Running-time1
1,2 l/3 h
2,1 l/3 h
2,4 l/8 h
2,4 l/8 h
Start-up system
Recoil
Recoil
Recoil
E-start incl. battery
Sound power level LWA2
96 dB(A)
97 dB(A)
97 dB(A)
97 dB(A)
Sound pressure level LPA3
71 dB(A)
72 dB(A)
72 dB(A)
72 dB(A)
Weight kg
53
100
117
120
Dimensions L x W x H in mm
555 x 405 x 445
820 x 495 x 570
870 x 562 x 640
870 x 562 x 640
Outfit
2 x 230 V/16 A
3 x 230 V/16 A
3 x 230 V/16 A
3 x 230 V/16 A
1 x CEE 400 V/16 A
1 x CEE 400 V/16 A
1 x CEE 230 V/16 A
1 x CEE 400 V/16 A
1 x CEE 400 V/16 A
Shockproof sockets
ESE 606 DBG ES Duplex
Cut-off when lack of oil (except for ESE 604 DHG ES Diesel), overload protection, start-stop system (types with E-start), handles (except Application areas*
230 V
400 V
230 V
400 V
230 V
400 V
230 V
Electronic loads up to
2400 W
4800 W
3600 W
4800 W
3600 W
4800 W
3600 W
Electric tools up to
2300 W
4700 W
3500 W
4700 W
3500 W
4700 W
3500 W
Construction equipment up to
1600 W
3200 W
2400 W
3200 W
2400 W
3200 W
2400 W
Inverter welding machines Compressors or pumps 1 2
*
3,25 mm 1100 W
2200 W
3,25 mm 1700 W
2200 W
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table.
3,25 mm 1700 W
2200 W
1700 W
Options - not retrofit 3-way fuel cock for ext. refuelling Duplex G5/Idle-down automatic Automatik Choke Automatik Choke Isometer Cable Remote control (50 m) Remote remole control Multifunctional-Control-System E-MCS 3.0 Detailed description you find on page 7 Warning signal kit fuel gauge incl. fuel level sensor NEW
Order No. 162 005 163 020 163 030 163 031 010 043 162 006 162 007 162 311
for ESE 606, ESE 1006, ESE 1306 DBG ES Duplex for ESE 606, ESE 1006, ESE 1306 DBG ES Duplex for ESE 606, ESE 1006 DBG ES Duplex for ESE 1306 DBG ES Duplex for all types except ESE 304 HG type with E-Start ESE 606, 1006, 1306, 808, 1308 type with E-Start ESE 606, 1006, 1306, 808, 1308 except for type series ESE 304 HG, ESE 604
162 312 162 313
for E-MCS 3.0 for E-MCS 3.0
NEW
ESE 1002 DHG ES Diesel DUPLEX
Not for EU countries
NEW
NEW
ESE 1006 DBG Duplex
ESE 1006 DBG ES Duplex
ESE 1306 DBG ES Duplex
ESE 604 DHG ES Diesel Duplex
ESE 1002 DHG ES Diesel Duplex
113 004
113 005
113 006
113 009
113 010
synchronous
synchronous
synchronous
synchronous
synchronous
12,1/9,7
6,6/5,9
12,1/9,7
6,6/5,9
14,3/11,4
7,7/6,9
6,5/5,3
4,4/4,0
11,0/8,8
6,0/5,4
11,0/8,8
6,0/5,4
11,0/8,8
6,0/5,4
13,0/10,4
7,0/6,3
6,0/4,8
4,0/3,6
10,0/8,0
5,5/5,0
400 V 3~
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1~
15,9 A 3~
25,0 A 1~
15,9 A 3~
25,0 A 1~
18,8 A 3~
30,4 A 1~
8,7 A 3~
18,0 A 1~
14,5 A 3~
21,7 A 1~
0,8
0,9
0,8
0,9
0,8
0,9
0,8
0,9
0,8
0,9
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
electronic
electronic
electronic
electronic
electronic
B & S V-Twin
B & S V-Twin
B & S V-Twin
HATZ 1B 40
HATZ 1 D81 C
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
1-cyl. 4-stroke
1-cyl. 4-stroke
570 cm3
570 cm3
627 cm3
462 cm3
667 cm3
13,4 kW/18,0 HP
13,4 kW/18,0 HP
16,7 kW/22,0 HP
6,2 kW/8,4 HP
10,0 kW/13,6 HP
Unleaded petrol/20
Unleaded petrol/20
Unleaded petrol/20
Diesel/6
Diesel/15
2,9 l/6,5 h
2,9 l/6,5 h
3,4 l/6,0 h
2,0 l/3 h
2,1 l/7 h
Recoil
E-start incl. battery
E-start incl. battery
E-start incl. battery
E-start incl. battery
97 dB(A)
97 dB(A)
96 dB(A)
72 dB(A)
72 dB(A)
71 dB(A)
115
120
144
133
870 x 562 x 640
870 x 562 x 640
870 x 562 x 640
820 x 495 x 570
1105 x 684 x 862
3 x 230 V/16 A
3 x 230 V/16 A
3 x 230 V/16 A
2 x 230 V/16 A
3 x 230 V/16 A
1 x CEE 230 V/16 A
1 x CEE 230 V/16 A
1 x CEE 400 V/16 A
1 x CEE 230 V/16 A
1 x CEE 400 V/16 A
1 x CEE 400 V/16 A
1 x CEE 400 V/16 A
1 x CEE 400 V/32 A
1 x CEE 400 V/16 A
97 dB(A) 72 dB(A) 290
for ESE 304 HG), crane loading device for ESE 1002 DHG ES Diesel 400 V
230 V
400 V
230 V
400 V
230 V
400 V
230 V
400 V
230 V
8800 W
5400 W
8800 W
5400 W
10400 W
6300 W
4800 W
3600 W
8000 W
6300 W
8700 W
5300 W
8700 W
5300 W
10300 W
6200 W
4700 W
3500 W
7900 W
6200 W
5800 W
3600 W
5800 W
3600 W
6900 W
4200 W
3200 W
2400 W
5300 W
4200 W
4,5 mm 4100 W
4,5 mm 2500 W
4100 W
6,5 mm 2500 W
4800 W
3,25 mm 2900 W
2200 W
4,5 mm 1700 W
DUPLEX-LINE
ESE 1306 DBG ES DUPLEX
G E N E R AT O R S
Includes run hour meter
3700 W
2900 W
23
Duplex Line Silent generators 8 - 13 kVA
DUPLEX-LINE
G E N E R AT O R S
ESE 1008 DHG ES Diesel Duplex Silent
Includes run hour meter
ESE 808 DBG ES Duplex Silent
Available accessories Refuelling system Exhaust pipe
Order No. 163 110 163 120
for ESE 808, ESE 1308 DBG ES Duplex Silent for ESE 808, ESE 1308 DBG ES Duplex Silent
Options - not retrofit Duplex G5/Idle-down Isometer Cable Remote control (50 m) Remote remole control Multifunktions-Control-System E-MCS 3.0 Detailed description you find on page 7 Warning signal kit Fuel gauge incl. Fuel level sensor
Order No. 163 020 010 043 162 006 162 007 162 311
for for for for for
162 312 162 313
for E-MCS 3.0 for E-MCS 3.0
•
ESE 808, ESE 1308 DBG ES Duplex Silent all types ESE 808, ESE 1308 DBG ES Duplex Silent ESE 808, ESE 1308 DBG ES Duplex Silent all types
NEW
24
• Elaborate silencing system for very • • •
NEW
good LWA data. Improved cooling air and exhaust concept for safer operation. Optimal operating comfort with new control panel. Larger tank for longer run time. Very good access for maintenance.
NEW
Type
ESE 808 DBG ES Duplex Silent
ESE 1308 DBG ES Duplex Silent
ESE 1008 DHG ES Diesel Duplex Silent
Order No.
113 007
113 008
113 011
Alternator/Duplex G4
synchronous
Max. output [LTP] kVA/kW
8,8/7,0
5,4/5,0
14,3/11,4
7,7/6,9
11,0/8,8
7,7/6,9
Constant rating [COP] kVA/kW 8,0/6,4
5,0/4,5
13,0/10,4
7,0/6,3
10,0/8,0
7,0/6,3
Nominal voltage
400 V 3~
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1~
Nominal current
12,3 A 3~
21,7 A 1~
18,8 A 3~
30,4 A 1~
14,4 A 3~
30,4 A 1~
Power factor cos (phi)
0,8
0,9
0,8
0,9
0,8
0,9
synchronous
synchronous
Frequency/Type of protection 50 Hz/IP 54
50 Hz/IP 54
50 Hz/IP 54
Voltage regulation
electronic
electronic
electronic
Engine type
B & S V-Twin
B & S V-Twin
HATZ 1 D81 C
Version
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
1-cyl. 4-stroke
Engine capacity
480 cm3
627 cm3
667 cm3
Max. output [LTP] kVA/kW
11,9 kW/16,0 HP
16,7 kW/22,0 HP
10,0 kW/13,6 HP
Fuel/Tank capacity (litres)
Unleaded petrol/20
Unleaded petrol/20
Diesel/15
Consumption/Running-time1
2,4 l/8 h
3,4 l/6 h
2,1 l/7 h
Start-up system
E-start incl. battery
E-start incl. battery
E-start incl. battery
Sound power level LWA2
92 dB(A)
93 dB(A)
96 dB(A)
Sound pressure level LPA3
67 dB(A)
68 dB(A)
71 dB(A)
Weight kg
137
148
320
Dimensions L x W x H in mm
820 x 440 x 580
820 x 440 x 580
1110 x 684 x 862
Outfit
3 x 230 V/16 A
3 x 230 V/16 A
3 x 230 V/16 A
Shockproof sockets
1 x CEE 230 V/16 A
1 x CEE 400 V/16 A
1 x CEE 400 V/16 A
1 x CEE 230 V/16 A
1 x CEE 400 V/32 A
Crane loading device
Cut-off when lack of oil, overload protection, handles, start-stop system Application areas*
400 V
230 V
400 V
230 V
400 V
230 V
Electronic loads up to
6400 W
4500 W
10400 W
6300 W
8000 W
6300 W
Electric tools up to
6300 W
4400 W
10300 W
6200 W
7900 W
6200 W
Construction equipment up to
4200 W
3000 W
6900 W
4200 W
5300 W
4200 W
Inverter welding machines up to 4,0 mm Compressors or pumps 1 2
*
3000 W
6,5 mm 2100 W
4800 W
4,5 mm 2900 W
3700 W
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table.
2900W
G E N E R AT O R S
SILENT POWER-LINE
Silent Power Line generators 5 - 12 kVA
25
The new Silent Power Line provides maximum performance and reliability. Designed for professional application where a reduced noise level is important.
G E N E R AT O R S
SILENT POWER-LINE
Silent Power Line generators
ESE 608 DBS ES Silent
NEW
26
Noise-controlled generators in robust and sturdy design. High quality construction and generous outfit are serial in all Silent Power line generators.
• High-quality 2-cylinder OHV engines. • Robust diesel engines. • Compound regulator at 400 V. • Low-oil cut-off protects the engine from damage due to lack of oil. • Generous tank volume for extended run time. • All generators with electric starter, including battery. • Very good access for maintenance. • Optimal operating comfort. • Side panels for perfect dust and weather protection.
Type
ESE 608 DBS ES Silent
Order No.
131 006
Alternator
synchronous
Max. output [LTP] kVA/kW
6,6/5,3
Constant rating [COP] kVA/kW
6,0/4,8
4,0/3,6
Nominal voltage
400 V 3 ~
230 V 1~
Nominal current
8,0 A ~
14,0 A 1~
Power factor cos (phi)
0,8
0,9
Frequency/Type of protection
50 Hz/IP 23
Engine type
B & S V-Twin
Version
2-cyl. 4-stroke OHV
Engine capacity
480 cm3
Max. output
7,5 kW/10,2 HP
4,5/4,0
Fuel/Tank capacity (litres)
Unleaded petrol/20
Consumption/Running-time1
2,4 l/8 h
Start-up system
E-start incl. battery
Sound power level LWA2
92 dB(A)
Sound pressure level LPA3
67 dB(A)
Weight kg
160
Dimensions L x W x H in mm
950 x 457 x 579
Outfit Shockproof sockets
2 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 400 V/16 A Operating hour meter start-stop system
Cut-off when lack of oil, overload Options not retrofit Cable Remote control (40 m cable) Cable Remote control (50 m cable)
Order No. 164 000 for type series ESE 1308 HS ES Silent, ESE 608 YS ES Diesel Silent 162 006 for type series ESE 608, ESE 1008 DBS ES Silent
Application areas*
400 V
230 V
Electric tools up to
4700 W
3500 W
Construction equipment up to
3200 W
2400 W
Inverter welding machines up to
2,5 mm
Compressors or pumps
2200 W
1600 W
NEW
NEW
ESE 1308 HS ES Silent
ESE 1308 DHS ES Silent
ESE 608 YS ES Diesel Silent
131 005
131 007
131 008
131 009
131 010
synchronous
synchronous
synchronous
synchronous
synchronous
ESE 608 DYS ES Diesel Silent
11,0/8,8
6,6/5,9
11,9/10,7
13,8/11
9,1/8,2
5,9/5,3
6,9/5,5
4,6/4,1
10,0/8,0
6,0/5,4
10,0/9,0
11,8/9,4
6,9/6,2
4,9/4,4
5,7/4,6
3,3/3,0
400 V 3~
230 V 1~
230 V 1~
400 V 3~
230 V 1~
230 V 1~
400 V 3~
230 V 1~
14,4 A ~
26,0 A 1~
43,5 A 1~
17 A 3~
30 A 1~
21,3 A 1~
8,2 A 3~
14,3 A 1~
0,8
0,9
0,9
0,8
0,9
0,9
0,8
0,9
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
B & S V-Twin
HONDA GX 620
HONDA GX 620
YANMAR L 100
YANMAR L 100
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
1-cyl. 4-stroke
1-cyl. 4-stroke
570 cm3
614 cm3
614 cm3
406 cm3
406 cm3
13,4 kW/18,0 HP
13,5 kW/18,4 HP
13,5 kW/18,4 HP
6,9 kW/9,4 HP
6,9 kW/9,4 HP
Unleaded petrol/20
Unleaded petrol/24
Unleaded petrol/24
Diesel/19
Diesel/19
2,9 l/7 h
3,4 l/7 h
3,4 l/7 h
1,4 l/13,5 h
1,4 l/13,5 h
E-start incl. battery
E-start incl. battery
E-start incl. battery
E-start incl. battery
E-start incl. battery
92 dB(A)
96 dB(A)
96 dB(A)
84 dB(A)
84 dB(A)
67 dB(A)
71 dB(A)
71 dB(A)
59 dB(A)
59 dB(A)
165
166
176
205
205
950 x 457 x 579
930 x 555 x 800
930 x 555 x 800
1050 x 620 x 830
1050 x 620 x 830
2 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 400 V/16 A Operating hour meter start-stop system
1 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/32 A
1 x 230 V/16 A 2 x CEE 230 V/16 A 1 x CEE 400 V/16 A
1 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/32 A Operating hour meter
1 x 230 V /16 A 1 x CEE 230 V/16 A 1 x CEE 400 V/16 A Operating hour meter
d protection, crane loading device 400 V
230 V
230 V
400 V
230 V
230 V
400 V
230 V
7900 W
5300 W
8900 W
9300 W
6100 W
4300 W
4500 W
2900 W
5300 W
3600 W
6000 W
6200 W
4100 W
2900 W
3000 W
2000 W
3700 W 1 2
*
5,0 mm 2500 W
4500 W
4700 W
3,25 mm 3100 W
2200 W
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table.
SILENT POWER-LINE
NEW
ESE 1008 DBS ES Silent
4,5 mm
G E N E R AT O R S
ESE 608 DYS ES Diesel Silent
ESE 1308 DHS ES Silent
2500 W
1500 W
27
nk with large ta All machines g n ri o n monit and insulatio
DIESEL-LINE
G E N E R AT O R S
Diesel Line generators 3 - 11 kVA
28
Type Order No. Alternator Max. output [LTP] kVA/kW Constant rating [COP] kVA/kW ESE 404 YS-GT ISO Diesel
Nominal voltage Nominal current/cos (phi) Power factor cos (phi) Frequency/Type of protection Engine type Version Engine capacity Max. output Fuel/Tank capacity (litres) Consumption/Running-time1
Diesel Line generators have modern quality diesel engines with direct injection. The machines are of high quality, reliability and long life. The engines meet the strictest emission standards and comply with the exhaust norms, e.g., CARB. These generators are preferably used in damp environments such as ducts and shafts, and in areas in which suitable grounding for the generator cannot be produced.
Start-up system Sound power level LWA2 Sound pressure level LPA3 Weight kg Dimensions L x W x H in mm Outfit Shockproof sockets
Application areas* Electric tools up to Construction equipment up to Inverter welding machines up to Compressors or pumps up to
Mature engineering for hard professional service. All models with the following serial features: Side walls for perfect protection against dust and weather, large tank and ISOMETER. The isometer provides highest safety and stops the voltage supply instantly in case of an electric fault.
G E N E R AT O R S
ng Including operati hour meter and ls set of site whee
DIESEL-LINE
ESE 1004 DRS-GT ISO Diesel
ESE 1204 DHS ES ISO Diesel
Available accessories Set of wheels Set of wheels Carrying handles Adapter CEE 230 V/16 A of Schuko 230 V/16 A One axle trailer FG 75 ST One axle trailer FG 75 HV
Order No. 161 000 161 001 161 002
for ESE 404 YS-GT ISO Diesel except for ESE 404 YS-GT, ESE 1204 DHS ES ISO Diesel for ESE 404 YS-GT ISO Diesel
162 004 341 100 341 101
for ESE 1204 DHS ES ISO Diesel for ESE 1204 DHS ES ISO Diesel
Options - not retrofit Cable remote control (40 m)
Order No. 164 000
except for ESE 404 YS-GT ISO Diesel
ESE 704 DYS-GT ES ISO Diesel
ESE 404 YS-GT ISO Diesel
ESE 604 YS-GT ES ISO Diesel
ESE 704 DYS-GT ES ISO Diesel
ESE 1004 DRS-GT ES ISO Diesel
ESE 1204 DHS ES ISO Diesel
122 001
131 002
122 003
122 004
122 005
synchronous
synchronous
synchronous
3,8/3,4
5,9/5,3
6,9/5,5
4,6/4,1
10,2/8,2
6,7/6,0
15,8/12,6
10,4/9,4
3,2/2,9
4,8/4,3
5,7/4,5
3,3/3,0
8,8/7,0
5,1/4,6
11,0/8,8
6,5/5,8
230 V 1~
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1~
13,9 A 1~
20,9 A 1~
8,2 A 3~
14,3 A 1~
12,7 A 3~
22,1 A 1~
15,9 A 3~
28,3 A 1~
0,9 50 Hz/IP 23
0,9 50 Hz/IP 23
0,8 0,9 50 Hz/IP 23
0,8 0,9 50 Hz/IP 23
0,8 0,9 50 Hz/IP 23
YANMAR L 70
YANMAR L 100
YANMAR L 100
RUGGERINI MD 150
HATZ 2G 40
1-cyl. 4-stroke
1-cyl. 4-stroke
1-cyl. 4-stroke
2-cyl. 4-stroke OHV
2-cyl. 4-stroke
296 cm3
406 cm3
406 cm3
654 cm3
997 cm3
synchronous
synchronous
4,8 kW/6,5 HP
6,9 kW/9,4 HP
6,9 kW/9,4 HP
10,0 kW/13,6 HP
15,4 kW/20,9 HP
Diesel/18
Diesel/24
Diesel/24
Diesel/24
Diesel/17
1,0 l/18 h
1,4 l/17 h
1,4 l/17 h
2,1 l/11,5 h
2,3 l/7,5 h
Recoil
E-start incl. battery
E-start incl. battery
E-start incl. battery
E-start incl. battery
96 dB(A)
97 dB(A)
97 dB(A)
97 dB(A)
97 dB(A)
71 dB(A)
72 dB(A)
72 dB(A)
72 dB(A)
72 dB(A)
98
149
153
193
275
800 x 520 x 660
930 x 555 x 800
930 x 555 x 800
930 x 555 x 800
1270 x 830 x 920
1 x 230 V/16 A 2 x CEE 230 V/16 A 1 x CEE 400 V/16 A Crane loading device
1 x 230 V/16 A 2 x CEE 230 V/16 A 1 x CEE 400 V/16 A Crane loading device
1 x CEE 230 V/16 A 1 x CEE 230 V/32 A 1 x CEE 400 V/16 A Crane loading device
1 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/16 A
1 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/32 A Crane loading device Voltmeter, isometer, overload protection 230 V
230 V
400 V
230 V
400 V
230 V
400 V
230 V
2800 W
4200 W
4400 W
2900 W
6900 W
4500 W
8700 W
5700 W
1900 W
2800 W
3000 W
2000 W
4600 W
3000 W
5800 W
3800 W
3,25 mm 1500 W
2100 W 1 2
*
2200 W
4,0 mm 1500 W
3500 W
4,5 mm 2300 W
4400 W
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table.
2900 W
29
G E N E R AT O R S
ACCORDING TO DIN 14685
Generators according to DIN 14685 3 - 15 kVA
30
M G
DUPLEX
ENDRESS generators according to DIN 14685 - reliable and robust helpers for harsh environments - for fire brigades, civil protection and rescue missions.
E
Convincing points for the DIN generators with DUPLEX technology
• Brushless synchronous generator with electronic control. • 4-time start-up current, 200% load unbalance. • Simultaneous operation of electronic and inductive consumers possible. • 20000 generator hours. Maintenance-free. • Automatic choke as serial feature in all versions with remote starter. • Engine protection by low oil cut-off. • Protection against overheating by heat deflection panels. Option: DUPLEX G5 technology Slows down the engine to the lowest possible speed in idle running.
•
The new DIN generators in 8-size frame, 8 - 13 kVA, set standards of quality, technology and outfit.
Multifunction Control System E-MSC 3.0 as standard. For a detailed description, see p. 7.
• Optimal operator comfort with new control panel.
• • • • •
The perfect multifunction control system from ENDRESS. A system for optimal safety and user friendliness in everyday use. CanBus capability included as standard.
G E N E R AT O R S
• •
All displays, control and operation functions at a glance. Keyless start by START/STOP/EMERGENCY STOP button. New place for the tank for less heating, less sensitive to temperature. Visual fuel level. 50% larger tank capacity. Improved tank opening, higher filler neck. New B & S V-Twin engines 0.5 dB(A) less noise than earlier model´lower oil temperature - higher life expectancy. Noise reduced by 3 dB(A).
Option: CanBus link-up The link between the unit and the customer’s operator panel is provided by a control interface unit (CIU). Before data can be exchanged, some customization must take place at the ENDRESS factory. Option: exhaust hose
Electronics
Option: Filling system
Control box
ESE 804 DBG ES DIN
Higher filler neck
ACCORDING TO DIN 14685
NEW
Visual fuel level in tank
31
ACCORDING TO DIN 14685
Generators according to DIN 14685 • Multifunction Control System E-MCS 3.0 • Keyless start by START/STOP/EMERGENCY STOP button. • New B & S V-Twin engines in ESE 854 DBG DIN • CanBus capability
G E N E R AT O R S
(except ESE 304 HG, ESE 604 DYG DIN).
ESE 604 DYG DIN
ESE 304 HG ESE 604 DBG DIN
aligned to DIN 14685
32
5er DIN frame
Type
ESE 304 HG
ESE 604 DYG DIN
ESE 604 DBG DIN
Order No.
151 000
151 001
1151 002
ESE 854 DBG DIN 151 004
Alternator/Duplex G4
synchronous
synchronous
synchronous
synchronous
Max. output [LTP] kVA/kW
3,3/3,0
6,6/5,3
4,4/4,0
6,6/5,3
4,4/4,0
8,8/7,0
5,5/5,0
Constant rating [COP] kVA/kW
3,0/2,4
6,0/4,8
4,0/3,6
6,0/4,8
4,0/3,6
8,0/6,4
5,0/4,5
Nominal voltage
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1~
Nominal current
13 A 1~
8,7 A 3~
18,0 A 1~
8,7 A 3~
18,0 A 1~
12,3 A 3~
21,7 A 1~
Power factor cos (phi)
0,9
0,8
0,9
0,8
0,9
0,8
0,9
Frequency/Type of protection
50 Hz/IP 54
50 Hz/IP 54
50 Hz/IP 54
50 Hz/IP 54
Voltage regulation
electronic
electronic
electronic
electronic
Engine type
HONDA GX 200
HONDA GX 390
B & S VANGUARD
B & S VANGUARD
Version
1-cyl. 4-stroke OHV
1-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
Engine capacity
196 cm3
357 cm3
480 cm3
480 cm3
Max. output
4,3 kW/5,8 HP
7,5 kW/10,2 HP
7,5 kW/10,2 HP
11,9 kW/16,0 HP
Fuel/Tank capacity (litres)
Unleaded petrol/3,6
Unleaded petrol/6,7
Unleaded petrol/8,5
Unleaded petrol/8,5
Consumption/Running-time1
1,2 l/3 h
2,1 l/3 h
2,4 l/3,5 h
2,4 l/3,5 h
Start-up system
Recoil
Recoil
Recoil
Recoil
Sound power level LWA2
96 dB(A)
97 dB(A)
97 dB(A)
97 dB(A)
Sound pressure level LPA2
71 dB(A)
72 dB(A)
72 dB(A)
72 dB(A)
Weight kg
53
95
117
114
Dimensions L x W x H in mm
555 x 405 x 445
700 x 440 x 580
700 x 440 x 580
700 x 440 x 580
Outfit
2 x 230 V/16 A
3 x 230 V/16 A, DIN 49442
Shockproof sockets
IP 68 according to VDE-norm
1 x CEE 400/16 A, DIN 49462
Overload protective switch
3 x 2-pole, 1 x 4-pole circuit breaker, protective conductor test equipment, cut-off when lack of oil,
Cut-off when lack of oil
On-board tool: 1 x spark plug spanner, 2 x spark plug, 1 x testing spike and 1 testing cable-1 m long Multifunction control display E-MCS 3.0 standard
Types with electric start without battery
ESE 604 DBG ES DIN
ESE 854 DBG ES DIN
Order No.
151 012
151 014
Types with electric start and remote control incl. automatic choke without battery
ESE 604 DBG ES FS DIN
ESE 854 DBG ES FS DIN
Order No.
151 022
151 024
1 2
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
ACCORDING TO DIN 14685
Modern and more powerful consumers need more output from mobile generators. The development of such units is governed by customer and market demands. Therefore, we constantly add new versions to our product lines. The new DUPLEX generators in size 8 DIN frame set new standards in precision and reliability.
Serial features:
G E N E R AT O R S
• Multifunction Control System E-MCS 3.0. • CanBus capability. • Carrying handles in flexible supports. • Visual fuel level. • Tank holds 12 liters ESE 1304 DBG ES DIN
8er DIN frame ESE 804 DBG DIN
ESE 1104 DBG ES DIN
151 003
151 015
ESE 1304 DBG ES DIN 151 016
synchronous
synchronous
synchronous
Optional: DUPLEX G5 technology Slows down the engine to the lowest possible speed in idle running.
8,8/7,0
5,5/5,0
12,1/9,7
7,7/6,9
14,3/11,4
7,7/6,9
8,0/6,4
5,0/4,5
11,0/8,8
7,0/6,3
13,0/10,4
7,0/6,3
400 V 3~
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1~
12,3 A 3~
21,7 A 1~
15,9 A 3~
30,4 A 1~
18,8 A 3~
30,4 A 1~
0,8
0,9
0,8
0,9
0,8
0,9
50 Hz/IP 54 DIN 40050
50 Hz/IP 54 DIN 40050
50 Hz/IP 54 DIN 40050
electronic
electronic
electronic
B & S VANGUARD
B & S VANGUARD
B & S VANGUARD
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
480 cm3
627 cm3
627 cm3
11,9 kW/16,0 HP
14,8 kW/20,0 HP
16,7 kW/22,0 HP
Unleaded petrol/20
Unleaded petrol/12,0
Unleaded petrol/12,0
2,4 l/5 h
3,4 l/3,5 h
3,4 l/3,5 h
Recoil
E-Start
E-Start
97 dB(A)
98 dB(A)
98 dB(A)
72 dB(A)
73 dB(A)
73 dB(A)
139
155
154
820 x 440 x 580
820 x 440 x 580
820 x 440 x 580
3 x shockproof sockets 230 V/16 A according to DIN 49442 2 x three-phase-CEE socket 400/16 A according to DIN 49462 handle elastically supported, optical fuel gauge, painting powder-coated RAL 1012 to testing device for earthed conductor ESE 804 DBG ES DIN 151 013
ESE 804 DBG ES FS DIN
ESE 1104 DBG ES FS DIN
ESE 1304 DBG ES FS DIN
151 023
151 025
151 026
Available accessories Battery 12 V - 18 Ah maintenance-free Refuelling system Exhaust pipe cable drum ELT 50/3
Options not retrofit 3-Way-Valve for ext. refuelling
33
Order No. 163 040 Range with E-start 163 110 suitable for 3-way-fuel cock 163 120 except for ESE 304 HG E 132 513
Order No. 163 050 Type series with B & S VANGUARD engines
Duplex-G5/ Idle down Isometer Automatic choke Automatic choke Part set - remote-start-Nato-socket Part set - battery charge with charging socket DIN 14690 Part set - battery charge with solenoide socket MagCode
163 010
Range with E-start
163 018
Warning signal kit II Fuel gauge incl. fuel level sensor Special sockets
162 312 162 313 on request
except for range 604 DBG, 854 DBG and ESE for E-MCS 3.0 for E-MCS 3.0
163 163 163 163 163
020 070 030 031 000
Range with E-start except for ESE 304 HG Range 6-8,5 kVA with E-start Range 11-13 kVA with E-start Range with E-start
ACCORDING TO DIN 14685 SILENT
G E N E R AT O R S
34
Generators according to DIN 14685 Silent • Multifunction Control System E-MCS 3.0. • Complete aluminum enclosure for • • • • • • • •
lower weight. Elaborate silencing system for very good LWA data. Improved cooling air and exhaust concept for safer operation. Optimal operating comfort with new control panel. Very good access for maintenance. 12h/18 Ah battery, maintenance-free. 3-way fuel cock for external filling. Visual fuel level. CanBus capability.
8er DIN Rahmen Type
ESE 804 DBG ES DIN
ESE 1304 DBG ES DIN
Silent
Silent
Order No.
151 413
151 416
Alternator/Duplex G4
synchronous
synchronous
Max. output [LTP] kVA/kW
8,8/7,0
5,5/5,0
14,3/11,4
7,7/6,9
Constant rating [COP] kVA/kW 8,0/6,4
5,0/4,5
13,0/10,4
7,0/6,3
Nominal voltage
400 V 3~
230 V 1~
400 V 3~
230 V 1~
Nominal current
12,3 A 3~
21,7 A 1~
18,8 A 3~
30,4 A 1~
Power factor cos (phi)
0,8
0,9
0,8
0,9
Frequency/Type of protection 50 Hz/IP 54
50 Hz/IP 54
Voltage regulation
electronic
electronic
Engine type
B & S VANGUARD
B & S VANGUARD
Version
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
Engine capacity
480 cm3
627 cm3
Max. output
11,9 kW/16,0 HP
16,7 kW/22,0 HP
Fuel/Tank capacity (litres)
Unleaded petrol/12
Unleaded petrol/12
Consumption/Running-time1
2,4 l/5 h
3,4 l/3,5 h
Start-up system
E-start incl. battery
E-start incl. battery
Sound power level LWA2
92 dB(A)
94 dB(A)
Sound pressure level LPA3
67 dB(A)
69 dB(A)
Weight kg
136
148
Dimensions L x W x H in mm
820 x 440 x 580
820 x 440 x 580
Outfit 3 x shockproof sockets 230 V/16 A, according to DIN 49442, 1 x CEE socket 400 V/16 A, according to DIN 49462, Multifunctional Control Display E-MCS 3.0 standard, 3 x 2-pole und 1 x 4-pole automatic circuit-breakers, testing device for earthed conductor, cut-off when lack of oil, 3-way-fuel valve for external fuelling, carrying handles elastically supported, optical fuel gauge, powdercoated RAL 1012. On-board tool: 1 x spark plug spanner, 2 x spark plug, 1 x testing spike and 1 testing cable1 m long to testing device for earthed conductor Types with electric start and remote start device incl. automatic choke and battery Type ESE 804 DBG ES FS DIN ESE 1304 DBG ES FS DIN Silent Silent Order No. 151 423 151 426 Available accessories Exhaust pipe Refuelling system 1 2
*
Order No. 163 120 163 110
all types suitable for 3-wax fuel cock
Options not retrofit Duplex G5/Idle-down Isometer Automatic choke Automatic choke Part set - remote-start-Nato-socket Part set - battery charge with charging socket DIN 14690 Part set - battery charge with solenoide socket MagCode Warning signal kit II Fuel gauge incl. fuel level sensor Special sockets
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. Options not retrofit.
Order No. 163 020 163 070 163 030 163 031 163 003
all types all types ESE 804 DBG ES DIN Silent ESE 1304 DBG ES DIN Silent all types
163 013
all types
163 018 162 312 162 313 on request
all types for E-MCS 3.0 for E-MCS 3.0
E M
TRIPLEX
G
TRIPLEX technology
• Engine speed adapts to output • • •
requirement. Optimal efficiency of the engine is used. Any type of current can be supplied. Any frequency can be generated.
For global use: constant voltage and frequency independent of the engine speed (variable speed constant frequency) 8er DIN frame Type
ESE 1504 DBT ES DIN TRIPLEX Silent
Order No.
151 800
Alternator
permanently excited
Max. output [LTP] kVA/kW
16,5/13,2
5,5/4,4
Constant rating [COP] kVA/kW 15,0/12,0
5,0/4,0
Nominal voltage
400 V 3~
230 V 1~
Nominal current
20,0 A 3~
21,8 A 1~
Power factor cos (phi)
0,8
0,9
TRIPLEX, the intelligent way of generating electricity. Low weight, compact unit and high efficiency are typical features of TRIPLEX generators. Engine, generator and electronics form an intelligent unit. The variable speed design of the unit and the automatic adjustment of the engine speed to the power requirement open versatile applications around the globe: whether 3-phase, AC or DV; 50 Hz, 60 Hz, 230 V or 115 V. Other frequencies can be generated reliably without complicated cooling or rectifier, e.g., 400 Hz on-board networks - or any other defined value.
Frequency/Type of protection 50 Hz/IP 54 Insulation class/Interf. degree F-VDE 05030/N-VDE 0875 Voltage regulation
electronic
Engine type
B & S VANGUARD
Version
2-cyl. 4-stroke OHV
Engine capacity
627 cm3
Max. output
16,7 kW/22,0 HP
Fuel/Tank capacity (litres)
Unleaded petrol/12
Consumption/Running-time1
3,4 l/3,5 h
Start-up system
E-start incl. battery
Sound power level LWA2
92 dB(A)
Sound pressure level LPA3
67 dB(A)
Weight kg
148
Dimensions L x W x H in mm
820 x 440 x 580
Outfit
User benefits
• Substantial reduction of pollutant and noise emission. • Reduced fuel consumption. • Less wear, longer engine life. smooth electricity under all conditions, distortion factor • Extremely less than 1%. • Ultrafine electronic assemblies can be used. • Each connection is isolated from all other connections. operation of machines which are difficult to start with sensitive • Mixed consumers is possible without hazard. lower operating costs due to extended service intervals • Substantially und less maintenance.
like ESE 1304 DBG ES DIN Silent see page 34 Available accessories Refuelling system
1 2
Order No. 163 110 suitable for 3-way fuel cock
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
ACCORDING TO DIN 14685 SILENT
VA Genuine 15 k frame in 8-size DIN
G E N E R AT O R S
Top-notch technology Fire brigades, emergency management and rescue services
35
Export Line generators 3 - 13 kVA
EXPORT-LINE
G E N E R AT O R S
Not for EU countries
Not for EC
36
ESE 404 YS Diesel
ESE 604 DYS ES Diesel
Profi Diesel This line employs high-quality diesel engines. Highperformance synchronous generators with strengthened phase winding are added. A sturdy monobloc tube frame with large side panels protects engine and alternator.
Type
Available accessories Set of wheels Crane loading device Refuelling system
Order No. 161 000 for all types E 101 115 for type ESE 1104 DBS, ESE 1104 DBS ES 163 110 for type ESE 1104 DBS, ESE 1104 DBS ES
Options - not retrofit Cable Remote control (40 m) Automatic control panel 3-way fuel cock Idle down Duplex G5
Order No. 164 000 162 311 162 005 162 200
for for for for
ESE 604 DYS ES Diesel, ESE 904 DRS ES ESE 604 DYS ES Diesel, ESE 904 DRS ES type ESE 1104 DBS, ESE 1104 DBS ES ESE 1314 DBG ES Duplex
ESE 404 YS
ESE 604 YS
ESE 604 DYS
ESE 604 DYS ES
ESE 904 DRS ES
Diesel
Diesel
Diesel
Diesel
Diesel
Order No.
121 000
121 004
121 001
121 002
121 003
Alternator
synchronous
synchronous
synchronous
synchronous
synchronous
Max. output [LTP] kVA/kW
3,9/3,5
5,9/5,3
6,9/5,5
4,6/4,1
6,9/5,5
4,6/4,1
10,2/8,21
Constant rating [COP] kVA/kW 3,3/3,0
4,8/4,3
5,7/4,5
3,3/3,0
5,7/4,5
3,3/3,0
8,8/7,0
6,7/6,0 5,1/4,6
Nominal voltage
230 V 1~
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1~
Nominal current
14,3 A 1~
20,9 A 1~
8,2 A 3~
14,3 A 1~
8,2 A 3~
14,3 A 1~
12,7 A 3~
22,2 A 1~
Power factor cos (phi)
0,9
0,9
0,8
0,9
0,8
0,9
0,8
0,9
Frequency/Type of protection 50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
Engine type
YANMAR L 70
YANMAR L 100
YANMAR L 100
YANMAR L 100
RUGGERINI MD 150
Version
1-cyl. 4-stroke
1-cyl. 4-stroke
1-cyl. 4-stroke
1-cyl. 4-stroke
2-cyl. 4-stroke
Engine capacity
296 cm3
406 cm3
406 cm3
406 cm3
654 cm3
Max. output
4,8 kW/6,5 HP
6,9 kW/9,4 HP
6,9 kW/9,4 HP
6,9 kW/9,4 HP
10,0 kW/13,6 HP
Fuel/Tank capacity (litres)
Diesel/3,5
Diesel/5,5
Diesel/5,5
Diesel/5,5
Diesel/24
Consumption/Running-time1
1,0 l/3,5 h
1,4 l/4 h
1,4 l/4 h
1,4 l/4 h
2,0 l/12 h
Start-up system
Recoil
Recoil
Recoil
E-start incl. battery
E-start incl. battery
Weight kg
54
100
96
112
153
Dimensions L x W x H in mm
760 x 490 x 530
800 x 575 x 570
800 x 575 x 570
830 x 490 x 570
970 x 600 x 690
Outfit Shockproof sockets
2 x 230 V/16 A
1 x 230 V/16 A 1 x CEE230 V/32 A
1 x 230 V/16 A 1 x CEE 400 V/16 A
2 x 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 400 V/16 A Voltmeter
1 x 230 V/16 A 1 x CEE 230 V/32 A 1 x CEE 400 V/16 A Voltmeter
Application areas*
230 V
230 V
400 V
230 V
400 V
230 V
400 V
Electric tools up to
2900 W
4200 W
4400 W
2900 W
4400 W
2900 W
6900 W
4500 W
Construction equipment up to
2000 W
2900 W
3000 W
2000 W
3000 W
2000 W
4600 W
3000 W
1400 W
3500 W
Overload protection
Inverter welding machines up to Compressors or pumps 1
1400 W
3,25 mm 2000 W
2200 W
3,25 mm 1400 W
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m. As the power needs of each consumer are influenced by various factors, no claims can be derived from this table. **Not for EU countries - export model ***Not according to directive 2000/14/EG 2
*
2200 W
230 V
4,0 mm 2300 W
countries! Not for EU countries
Where large and heavy units were needed for 25 kVA supply, today the handy ENDRESS Power Pack ESE 1314 DBG ES DUPLEX is enough.
EXPORT-LINE
G E N E R AT O R S
el Including 3-wayfu e ibl tank and collaps handles
ESE 1104 DBS
ESE 1104 DBS for harsh professional duty
• B & S VANGUARD 2-cylinder OHV engine. • High-performance synchronous generators. • Compound regulator at 400 V. • Large side panels protect engine and generator. • Handles. ESE 4000 DS
ESE 5000 DS
ESE 5000 DS ES
Diesel
Diesel
Diesel
ESE 1314 DBG ES Duplex
ESE 1104 DBS
ESE 1104 DBS ES
ESE 1314 DBS ES Duplex
250 001
250 002
250 003
121 005
121 006
051 307
synchronous
synchronous
synchronous
synchronous
synchronous
synchronous/Duplex-G4
3,6/3,2
5,4/4,9
5,4/4,9
11,0/8,8
6,6/5,9
11,0/8,8
6,6/5,9
14,3/11,4
7,7/6,9
3,3/3,0
4,8/4,3
4,8/4,3
10,0/8,0
6,0/5,4
10,0/8,0
6,0/5,4
13,0/10,4
7,0/6,3
230 V 1~
230 V 1~
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1~
400 V 3~
230 V 1
14,3 A 1~
20,7 A 1~
20,7 A 1~
14,4 A 3~
26,1 A 1~
14,4 A 3~
26,1 A 1~
14,4 A 3~
26,1 A 1~
0,9
0,9
0,9
0,8
0,9
0,8
0,9
0,8
0,9
50 Hz/IP 23 M
50 Hz/IP 23 M
50 Hz/IP 23 M
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 23
B & S VANGUARD
B & S VANGUARD
B & S VANGUARD
1-cyl. 4-stroke
1-cyl. 4-stroke
1-cyl. 4-stroke
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
2-cyl. 4-stroke OHV
296 cm3
406 cm3
406 cm3
570 cm3
570 cm3
627 cm3
4,0 kW/5,4 HP
6,5 kW/8,8 HP
6,5 kW/8,8 HP
12,0 kW/16,3 HP
12,0 kW/16,3 HP
14,8 kW/20,1 HP
Diesel/30
Diesel/30
Diesel/30
Unleaded petrol/8,5
Unleaded petrol/8,5
Unleaded petrol/8,5
1,0 l/30 h
1,5 l/20 h
1,5 l/20 h
2,8 l/3 h
2,8 l/3 h
3,4 l/2,5 h
Recoil
Recoil
E-start incl. battery
Recoil
E-start incl. battery
E-start incl. battery
73
89
107
103
107
144
805 x 558 x 580
805 x 558 x 580
805 x 558 x 580
945 x 570 x 640
945 x 570 x 640
820 x 440 x 580
2 x 230 V/16 A
1 x 230 V/16 A 1 x CEE 230 V/32 A
1 x 230 V/16 A 1 x CEE 230 V/32 A
2 x 230 V/16 A 1 x CEE400 V/16 A Cut-off when lack of oil Handles
2 x 230 V/16 A 1 x CEE 400 V/16 A Cut-off when lack of oil Handles
3 x 230 V/16 A 1 x CEE 400 V/16 A 1 x CEE 400 V/32 A Cut-off when lack of oil
230 V
230 V
230 V
400 V
230 V
400 V
230 V
400 V
230 V
2900 W
4200 W
4200 W
7900 W
5300 W
7900 W
5300 W
10400 W
6200 W
2000 W
2800 W
2800 W
5300 W
3600 W
5300 W
3600 W
6900 W
4200 W
4,5 mm 1400 W
2100 W
2100 W
4000 W
4,5 mm 2700 W
4000 W
6,5 mm 2700 W
5200 W
2900 W
37
EMERGENCY POWER SUPPLY
Mobile emergency supply
for 230rsV consume
G E N E R AT O R S
Professional emergency power supply for the in-house network
38 Please note! The power requirement must not be higher than the continuous output of the set. Otherwise damage can occur. Recommended: Always remain 10% below the continuous output. This extends the life of the machine. Important! The in-house installation and feeding connection must be made by a specialized electrical installation firm which warrants the proper and safe installation. That firm will also advise you as to the choice of the correct emergency supply set. Inform your electricity supplier of your intention and study the supplier’s general terms. Conditions are different from country to country.
5 steps for quick emergency supply 1 Generator set outdoors - set it up at a place protected from rain and moisture. 2 Make the connection between the generator set and the consumers. 3 Start the set. 4 Set the switch of the ENDRESS manual transfer switch to “emergency supply”. 5 Electricity is supplied. Simple and quick power supply in the whole house with the ENDRESS emergency set, a reliable supply source for all important 230 V consumers. The ENDRESS emergency set ensures that emergency power is available throughout the house in very short time. No extension cables or multiple socket outlets. The feeding distributor E-NEV/1 ensures that 230 V supplied by the generator is distributed to emergency consumers in the house via distribution boxes.
EMERGENCY POWER SUPPLY
G E N E R AT O R S
39 An important advantage of this system is that there is no need to check if the consumers in the house need grounded supply because the feeding distributor ensures that the generator set is automatically integrated in the in-house network. For use in DIY rooms and similar environments, simply separate the set from the in-house network for unrestricted mobile application.
230 V load
Standby-set with the Professional GT Line 2-11 kVA Type
ESE 606 HS-GT
ESE 1206 HS-GT ES
Order No.
112 002
112 021
Type manual transfer switch
E-NEV/3-32
E-NEV/3-32
Order No.
162 301
162 301
Max. connection power
5400 W
10000 W
Recommended collecting power
4900 W
9000 W
Possible application areas
Heating system Lighting Multimedia Communication Appliances Cooling
Heating system Lighting Multimedia Communication Appliances Cooling Pumps Warm water preparation
Detailed description and technical data you find on page 17-18.
ESE 1206 HS-GT ES
Mobile emergency supply
for 400rsV consume
G E N E R AT O R S
EMERGENCY POWER SUPPLY
Professional emergency power supply for the in-house network
40 5 steps for quick emergency supply 1 2 3 4 5
PETROL
Standby set with the DUPLEX-LINE 6-13 kVA Type
400 V load
The perfect emergency power supply in the whole house - without extension cables or multiple outlet sockets. The ENDRESS emergency set is a reliable emergency power source for all consumers.
Generator set outdoors - set it up at a place protected from rain and moisture. Make the connection between the generator set and the consumers. Start the set. Set the switch of the ENDRESS manual transfer switch to "emergency supply". Electricity is supplied.
ESE 604 DHG
ESE 606 DBG
ESE 606 DBG ES
ESE 1006 DBG
ESE 1006 DBG ES
Duplex
Duplex
Duplex
Duplex
Duplex
Duplex
Order No.
113 000
113 002
113 003
113 004
113 005
113 006
Type manual transfer switch
E-NEV/3-16
E-NEV/3-16
E-NEV/3-16
E-NEV/3-16
E-NEV/3-16
E-NEV/3-32
Order No.
162 303
162 303
162 303
162 303
162 303
162 304
Max. connection power
4800 W
4800 W
4800 W
8800 W
8800 W
10400 W
Recommended collecting power
4300 W
4300 W
4300 W
8100 W
8100 W
9400 W
Possible application areas Detailed description and technical data you find on page 22-23.
Complete house supply
ESE 1306 DBG ES
Synchronous 3-phase generators are not the best choice for 3-phase emergency supply. Because they cannot stand unbalanced load*. For this reason, ENDRESS uses the proven G4 DUPLEX technology for safe and reliable 3-phase emergency supply. * Unbalanced load is the state in which the phases of a 3-phase system carry unequal load.
If needed, simply separate the set from the in-house network for unrestricted mobile application.
The advantage of the Duplex technology is that the brushless synchronous generator IP 54 has full electronic control and can stand 200% load unbalance. Besides, this technology provides 100% constant voltage, distortion factor of less than 5% and 4 times the start-up current. This makes these sets not only suitable for the private home but also for small businesses to maintain computer supply in the case of a power outage. Thus, these generators are best for the difficult requirements which consumers make on an emergency generating set.
EMERGENCY POWER SUPPLY
The decisive advantage
G E N E R AT O R S
With this system, power is fed from the set into the in-house network via feeding distributor E-NV/3. This configuration is the same as a standard 3-phase feeding system known from the supplying network. All consumers, including 3-phase, in the house can be supplied. Emergency power sets in combination with the proven DUPLEX technology make a perfect match for emergency power supply in the whole house.
41
ESE 1308 ES Duplex Silent
ESE 1008 DBG ES Diesel Duplex Silent
SOUNDPROOF
D IE SEL
Standby set with the DUPLEX-LINE 6-13 kVA
400 V load
Type
ESE 808 DBG ES
ESE 1308 DBG ES
ESE 1002 DHG ES
ESE 1008 DHG ES
Duplex Silent
Duplex Silent
Diesel Duplex
Diesel Duplex Silent
Diesel Duplex
Order No.
113 007
113 008
113 010
113 011
113 009
Type manual transfer switch
E-NEV/3-16
E-NEV/3-32
E-NEV/3-16
E-NEV/3-16
E-NEV/3-16
Order No.
162 303
162 304
162 303
162 303
162 303
Max. connection power
6400 W
10400 W
8000 W
8000 W
4800 W
Recommended collecting power
5800 W
9400 W
7200 W
7200 W
4300 W
Possible application areas Detailed description and technical data you find on page 22-23.
Complete house supply
ESE 606 DBG ES
G E N E R AT O R S
EMERGENCY POWER SUPPLY
Automatic power supply
42 ENDRESS fully automatic emergency generator systems, together with the automatic control unit, automatically restore the power supply if the mains supply fails. The mains voltage is monitored automatically and if a drop is detected in one
PETROL
TYPE SERIES 5-12 kVA
230 V load
Type
or several phases, the engine starts automatically - manual starting is also possible. When the power supply is restored, the set cuts out automatically.
ESE 606 HS-GT/A
ESE 1206 HS-GT/A
DIESEL ESE 1308 HS/A
ESE 604 YS-GT/A
ESE 608 YS/A
Silent
Diesel
Diesel Silent
Order No.
112 105
112 106
131 105
122 105
131 106
Max. connection power
5500 W
9100 W
9100 W
4300 W
4400 W
Recommended demand power
5000 W
8200 W
8200 W
3900 W
4000 W
Possible application areas
Heating system Lighting Multimedia Communication Appliances Cooling
Heating system Lighting Multimedia Communication Appliances Cooling Pumps Warm waterpreparation
Heating system Lighting Multimedia Communication Appliances Cooling Pumps Warm waterpreparation
Heating system Lighting Multimedia Communication Appliances
Heating system Lighting Multimedia Communication Appliances
page 27
page 29
page 29
Detailed description and specifications you find on page 17-18.
EMERGENCY POWER SUPPLY
ENDRESS automatic emergency set 5 - 13 kVA. This series is a complete system with latest generator technology. The high-performance synchronous generators supply single-phase 230 V consumers in the house. For 3-phase supply, ENDRESS uses DUPLEX generators (a brushless synchronous
generator IP 54 with electronic control), which are excellent for individual household consumers, also for medium-size businesses, e.g., to maintain the power supply to computers in case of a mains power outage.
G E N E R AT O R S
5-12 kVA 1-phase feeding series These generators are factory wired with the automatic emergency machine and therefore need no socket outlet. Automatic emergency function cannot be service fitted.
8-13 kVA 3-phase feeding series The connection of the automatic emergency function in these models is made by a separate connection to the set, which can also be disconnected and used for mobile applications.
43 Only strong components will make powerful generators. For reasons of technical competence, ENDRESS relies on high-end industrial engines from DEUTZ and VOLVO Penta as well as quality generators from STAMFORD and Mecc Alte. (Detailed system descriptions from p. 54).
PETROL
TYPE SERIES 6-13 kVA
400 V load
Type
SOUNDPROOF
ESE 606 DBG/A
ESE 1006 DBG/A
ESE 1306 DBG/A
ESE 808 DBG/A
Duplex
Duplex
Duplex
Duplex Silent
Duplex Silent
Order No.
113 200
113 201
113 202
113 203
113 204
Max. connection power
4800 W
8800 W
10400 W
6400 W
10400 W
Recommended collecting power
4300 W
8100 W
9400 W
5800 W
9400 W
Possible application areas
Complete house supply
DIESEL
TYPE SERIES 6-13 kVA Type
ESE 1002 DHG/A
ESE 1008 DHG/A
Diesel Duplex
Diesel Duplex Silent
Order No.
113 207
113 206
Max. connection power
8000 W
8000 W
Recommended collecting power
7200 W
7200 W
Possible application areas
Complete house supply
Detailed description and specifications you find on page 22-24.
ESE 1308 DBG/A
G E N E R AT O R S
WELDING-LINE
Welding Line generators 30 - 200 A
44 Welding generator selection chart The table below can be used for guidance and does not purport to be exhaustive. No claims can be based on this table. ESE 704 SHS-AC ESE 804 SDHA-DC ESE 804 SDHA-DC ES
ENDRESS welding generators are versatile energy sources which supply three-phase, alternating and welding currents. Due to their excellent welding characteristics, they are simply indispensable for repair work such as in steel and pipeline engineering.
On-load factor (OLF) OLF = tb x 100% (tb + tp) tb = load duration tp = pause duration tb + tp = cycle duration (acc. To VDE 0544. tb + tp = 10 min) Example: 60% on-load factor yields a succession of 6 min welding and 4 min pause.
ø 1,5
50
ø2
70
ø 2,5
90
ø 3,25
110
ø 3,25
130
ø 3,25
150
ø4
170
ø4
190
ø5
210
ø5
35 % ED
60 % ED
35 % ED
Electrode
30
100 % ED
welding current (A)
60 % ED
ESE 504 SDHA
100 % ED
ESE 404 SHS-AC ESE 504 SDHA-DC ESE 504 SDYA-DC ES Diesel
• Continuous welding current regulation - at constant motor speed. • Silent, easy ignitable arcs, drop weld proof, K symbol (only at DC-models). • Modern HONDA-OHV engine technology. • Economical, reliable diesel units. • Sturdy asynchronous generators. • AC = AC welding for simple welding. • DC = DC welding for professional welding. ESE 404 SHS-AC
ESE 804 SDYA-DC ES
Not for EC-countries Type
ESE 404 SHS-AC
ESE 704 SHS-AC
ESE 504 SDHA-DC
ESE 804 SDHA-DC
ESE 504 SDYA-DC ES
Order No.
141 008
141 007
141 000
141 001
141 003
Alternator
synchronous
synchronous
asynchronous
asynchronous
asynchronous
Max. output [LTP] kVA/kW
3,9/3,5
6,9/6,2
5,0/4,0
4,4/4,0
6,4/5,1
4,4/4,0
5,3/4,2
4,4/40
Constant rating [COP] kVA/kW
3,3/3,0
5,9/5,3
4,5/3,6
4,0/3,6
6,0/4,8
4,0/3,6
5,0/4,0
4,0/3,6
Nominal voltage
230 V 1~
230 V 1~
400 V 3~ 230 V 1~
Nominal current
14,3 A 1~
25,7 A 1~
6,5 A 3~ 17,4 A 1~
8,7 A 3~ 17,4 A 1~
7,2 A 3~
17,4 A
Power factor cos (phi)
0,9
0,9
0,8
0,8
0,8
0,9
Frequency/Type of protection
50 Hz/IP 23
50 Hz/IP 23
50 Hz/IP 44
50 Hz/IP 44
Min./Max. welding output (A)
60 - 180
60 - 200
30 - 170
30 - 200
30 - 180
180
130
170
140
DIESEL
Welding current intensity at 60 % (A) 125
0,9
400 V 3~ 230 V 1~ 0,9
400 V 1~ 230 V 1~
50 Hz/IP 44
Off-load voltage (V)
45 ÷ 60
45 ÷ 60
95
95
95
Min./Max. welding voltage (V)
22,4/27,2
22,4/28
21,2/26,8
21,2/28,0
21,2/27,2
Welding regulation
mechanical
mechanical
mechanical
mechanical
mechanical
Engine type
HONDA GX 270
HONDA GX 390
HONDA GX 270
HONDA GX 390
YANMAR L 100 AE
Engine version
1-cyl. 4-stroke OHV
1-cyl. 4-stroke OHV
1-cyl. 4-stroke
1-cyl. 4-stroke OHV
1-cyl. 4-stroke
Engine capacity
270 cm³
389 cm³
270 cm³
389 cm³
406 cm³
Max. output
6,3 kW/8,6 HP
8,3 kW/11,3 HP
6,3 kW/8,6 HP
8,3 kW/11,3 HP
6,9 kW/9,4 HP
Fuel/Tank capacity (litres)
Unleaded petrol/6
Unleaded petrol/6,5
Unleaded petrol/6
Unleaded petrol/6,5
Diesel/24
Consumption/Running-time1
1,7 l/,5 h
2,1/3 h
1,65 l/3,5 h
2,1 l/3 h
1,4 l/17 h
Start-up system
Recoil
Recoil
Recoil
Recoil
E-start incl. battery
Sound power level LWA2
97 dB(A)
97 dB(A)
97 dB(A)
Sound pressure level LPA3
72 dB(A)
72 dB(A)
72 dB(A)
Weight kg
62
76
115
115
180
Dimensions L x W x H in mm
802 x 510 x 510
802 x 510 x 510
830 x 490 x 570
830 x 490 x 570
930 x 555 x 800
Outfit
2 x 230 V/16 A
2 x 230 V/16 A
1 x CEE 230 V/16 A
1 x CEE 230 V/16 A
3 x CEE 230 V/16 A Voltmeter
Cut-off when lack of oil Thermic winding shield, overload protection Type
ESE 804 SDHA-DC ES
Order No.
141 002 with E-start incl. battery
Available accessories Adapter CEE 230 V/16 A to shockproof socket 230 V/16 A
162 004
162 004
162 004
162 004
162 004
Set of wheels with handles
161 000
161 000
161 000
161 000
161 001
Welding accessories
162 000
162 000
162 000
162 000
162 000
Application areas Rutile electrode max. Ø mm
4
4
4
5
4
Basic electrode max. Ø mm
–
–
3,25
4
4
Cellulose electrode max. Ø mm
–
–
3,25
5
4
1 2
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
G E N E R AT O R S
ESE 704 SHS-AC front view
WELDING-LINE
ESE 404 SHS-AC front view
45
G E N E R AT O R S
PTO GENERATORS
PTO generators 12 - 55 kVA
46 Types with 3000 rpm Type
EZG 11/2
EZG 15/2
EZG 20/2
EZG 25/2
EZG 29/2
Order No.
511 007
511 008
511 009
511 010
511 011
EZG 35/2 511 012
Alternator
synchronous
synchronous
synchronous
synchronous
synchronous
synchronous
Constant rating [COP] kVA/kW
21,1/9,7
14,4/11,5
19,8/15,9
24,3/19,4
28,3/22,7
34,2/27,4
Nominal voltage
400 V 3~/230 V 1~
400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~
Nominal current
17,5 A 3~
20,8 A 3~
28,6 A 3~
35,1 A 3~
40,8 A 3~
49,4 A 3~
Power factor cos (phi)
0,8
0,8
0,8
0,8
0,8
0,8
Frequency/Type of protection
50 Hz/IP 44
50 Hz/IP 44
50 Hz/IP 44
50 Hz/IP 44
50 Hz/IP 44
50 Hz/IP 44
Power requirement at take-off (kW) 13
15,5
21
25
29
34
Alternator rpm
3000
3000
3000
3000
3000
3000
Weight kg
115
124
144
154
188
209
Dimensions L x W x H in mm
929 x 640 x 915
929 x 640 x 915
929 x 640 x 915
929 x 640 x 915
1135 x 640 x 915
1135 x 640 x 915
Outfit
1 x CEE 230 V/16 A
1 x CEE 230 V/16 A
1 x CEE 230 V/16 A 1 x CEE 230 V/16 A
1 x CEE 230 V/16 A 1 x CEE 230 V/16 A
Shockproof sockets
1 x CEE 400 V/16 A
1 x CEE 400 V/32 A
1 x CEE 400 V/32 A 1 x CEE 400 V/32 A
1 x CEE 400 V/63 A 1 x CEE 400 V/63 A
• • • •
• • • •
• • • • • •
• • • • • •
Residual current device 4-pole fuse protection 2-pole fuse protection Voltmeter Frequency meter amperemeter Operating hour meter
• • • • • •
• • • • • •
Mobile power sources for communities, building and agriculture.
PTO GENERATORS
A cost-effective power supply possibility is provided by the ENDRESS power take-off generators, as they are simply coupled on to existing farm tractors, municipal tractors or an UNIMOG vehicle. With no need to invest in an additional engine, highly efficient energy sources are available in an emergency or mobile use.
G E N E R AT O R S
An ENDRESS power take-off generator substantially improves the versatility and utilization of e.g. municipal tractors, provides a secure supply and widens the application capabilities of many electrical appliances and machines.
Top rate equipment and quality
• RCD with voltmeter and frequency meter. • Robust synchronous generators. • Compound regulation in models with 3000 rpm. • Electronic AVR control in models with 1500 rpm. • 3-point linkage for tractor mounting. • Standard shaft linkage - 450 rpm rated speed. • High protection type IP 44. • Silent transmission runs in oil bath.
47 Types with 1500 rpm EZG 30/4
EZG 40/4
EZG 50/4
511 013
511 014
511 015
EZG 60/4 511 016
synchronous
synchronous
synchronous
synchronous
27,0/21,6
36,5/29,2
46,1/36,9
54,8/43,8
Voltage monitoring module
400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 39,0 A 3~
52,7 A 3~
66,5 A 3~
79,1 A 3~
0,8
0,8
0,8
0,8
50 Hz/IP 44
50 Hz/IP 44
50 Hz/IP 44
50 Hz/IP 44
28
39
48
57
1500
1500
1500
1500
223
345
361
392
1135 x 640 x 915
1172 x 640 x 918
1172 x 640 x 918
1172 x 6440 x 918
1 x 230 V/16 A
1 x 230 V/16 A
1 x CEE 230 V/32 A 1 x 230 V/16 A 1 x CEE V/63 A
• • • • • •
1 x CEE 230 V/32 A 1 x CEE 230 V/32 A
1 x CEE 230 V/32 A
1 x CEE 400 V/63 A 1 x CEE 400 V/63 A
1 x CEE 400 V/125
• • • • • • •
• • • • • • •
• • • • • • •
The voltage monitor controls the output voltages to the socket outlets. If the permitted values are undershot or exceeded the electronic unit of the voltage monitor will give out a signal on the circuit relay (protection) and interrupt the output voltage to the socket outlets.
Available accessories Earth rod Voltage monitoring module
Order No. 342 304 512 000
Adapter CEE 230 V/16 A to Shockproof socket 230 V/16 A
162 004
G E N E R AT O R S
ENGINE PUMPS
Motor pumps from 600 - 1340 l/min
40
30
48 max. För derhöhe in Mete r Max. delivery head in meters
20
10
0
300
600
900
1200
1500
Förderleistung in Liter/mi n Delivery in liters
Tough, robust motor pumps for the harsh use in construction, industry, communities, agriculture and rigging.
Using world-wide proven HONDA OHV engines with long service life, easy start-up and high reliability. Top quality materials for all pump components afford full functionality, good performance and little need for maintenance at all times. Due to their robust design, self-priming sewage pumps from ENDRESS allow for a professional transport of clean and heavily soiled water in construction, industry, agriculture and communities. An ENDRESS motor pump ensures independence from electricity and water mains and gives the necessary security every time.
The versatile ENDRESS centrifugal pumps are in their element when a high flow rate and high output are required. The following examples are typical applications for which they can be used: Draining of ditches, cable shafts, basements, foundation pits or sewage works, irrigation of fields as well as the emptying and filling of ponds, the drainage of quarries, pits and coal mines.
EMP 305 T
Depending on the model, centrifugal pumps allow a maximum of 27mm solids through. Both the gyroscope and impeller are well resistant to abrasion and in addition sealing elements which run in an oil bath give the necessary reliability under the most severe of operating conditions. Cleaning is facilitated to a large extent by two swing-out closure blocks.
Rotary pumps
Engine pumps with decisive advantages OHV engine technology from HONDA. Very high delivery rates. Extremely high insensitivity to impurity laden water. Tough and long life due to a resistance to abrasive materials.
• • • •
Dirty.water pumps
Type
EMP 205
EMP 305
EMP 205 T
EMP 305 T
Order No.
411 000
411 001
411 002
411 003
Max. flow rate
600 l/min (36 m3/h)
930 l/min (55,8 m3/h)
700 l/min (42 m3/h)
1340 l/min (80,4 m3/h)
Max. suction lift in m
8m
8m
8m
8m
Max. total delivery height
30 m
26 m
30 m
27 m
Solids Ø mm
3 mm
7 mm
20 mm
27 mm
Connection S/D
2’’ x 2’’
3’’ x 3’’
2’’ x 2’’
3’’ x 3’’
Axie sealing
Carbon ceramics
Carbon ceramics
Silikon carbid
Silikon carbid
Engine type
HONDA GX 120
HONDA GX 160
HONDA GX 160
HONDA GX 240
Version
1-cyl. 4-stroke OHV
1-cyl. 4-stroke OHV
1-cyl. 4-stroke OHV
1-cyl. 4-stroke OHV
Engine capacity
118 cm3
163 cm3
163 cm3
242 cm3
Max. output
2,9 kW/3,9 HP
4,1 kW/5,6 HP
4,1 kW/5,6 HP
5,9 kW/8,0 HP
Rotation speed rpm
3600
3600
3600
3600
Fuel/Tank capacity (litres)
Unleaded petrol/2,5
Unleaded petrol/3,6
Unleaded petrol/3,6
Unleaded petrol/6
Consumption/Running-time1
1,25 l/2 h
1,8 l/2 h
1,7 l/2 h
2,6 l/2,3 h
Start-up system
Recoil
Recoil
Recoil
Recoil
Sound power level LWA2
103 dB(A)
105 dB(A)
106 dB(A)
110 dB(A)
Sound pressure level LPA3
78 dB(A)
80 dB(A)
81 dB(A)
95 dB(A)
Weight kg
20
29
47
58
Dimensions L x W x H in mm
468 x 352 x 385
505 x 374 x 453
620 x 462 x 481
690 x 485 x 537
Outfit Possible application areas
Cut-off when lack of oil, 3 x hose clip, 2 x hose couplings, 1 x stainer, spark plug spanner Rotary pumps for irrigation and drainage, extraction Dirty-water pump of clear or only moderately polluted media for irrigation and drainage in construction industry and agriculture
Sturdy dirty-water pump for industrial, municipal and agricultural application
Available accessories Suction tube 2’’ 8 m
38 410
Suction tube 2’’ 8 m Pressure tube 2’’ 15 m Pressure tube-extension 2’’ 10 m
38 410 38 407
38 411
Pressure tube 2’’ 15 m
38 407 38 411
38 408 38 414
38 408 38 414
Pressure tube-extension 3’’ 10 m
38 409
38 409
Reduction coupling 3’’ to 2’’
38 483
38 483
Suction tube, Pressure tube and pressure tube extension are equipped with quick couplings. 1
ENGINE PUMPS
EMP 305
G E N E R AT O R S
EMP 205
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
49
BUILDING SITE GENERATORS
G E N E R AT O R S
Building site generators 13 - 40 kVA
50
ESE 40 DL-B
ENDRESS power supply installations meet the EC machine and low voltage directives as well as the requirements of DIN VDE 0100. These sound damped, all-round protected diesel units are made for the rough service on construction sites in. They are equipped with high-quality generators according to VDE 0530 (insulation of class H) and conceived for highest output on harshest operating conditions.
• Maintenance intervals only every 1000 working • • • • • •
hours with oil cooling. Fittings and hinges of stainless material. Operation with less vibration. Low noise emission. No projecting parts. Constant voltage control AVR (ESE 30/40 DL-B and higher). Service friendly due to modular construction.
Order No. 341 102 341 103
DIN-pull eyelet 40 mm for lorry Rear parking supports, (1 pair) Supporting wheel, semi automatic
341 501 341 500 341 502
*reinforced version ST = rigid drawbar
all types all types
HV = height adjustable drawbar
Type
ESE 15 DW-B
ESE 20 DW-B
ESE 30 DL-B
Order No.
310 009
310 010
310 002
ESE 40 DL-B 310 003
Max. output [LTP] kVA/kW
13,8/11,0
20,1/16,1
30,0/24,0
41,2/33,0
Constant rating [COP] kVA/kW 13,0/10,4
19,0/15,2
29,0/23,2
39,3/31,4
Alternator type
LINZ E1S 13M 4-13 kVA
LINZ E1S 13M 4-19 kVA
STAMFORD BCI 184 F
STAMFORD BCI 184 J
Version/Insulation
synchronous/class H
synchronous/class H
synchronous/class H
synchronous/class H
Nominal voltage
400 V 3~/230 V 1~
400 V 3~/230 V 1~
400 V 3~/230 V 1~
400 V 3~/230 V 1~
Nominal current/cos (phi)
18,8 A 3~/0,8
27,4 A 3~/0,8
41,9 A 3~/0,8
56,7 A 3~/0,8
Frequency
50 Hz
50 Hz
50 Hz
50 Hz
Regulation
Compound
Compound
Electronic (± 1,5)
Electronic (± 1,5)
Engine type
DEUTZ D2009 L03
DEUTZ D2009 L04
DEUTZ F4M 2011
DEUTZ F4M 2011
Version
3-cyl. 4-stroke Diesel
4-cyl. 4-stroke Diesel
4-cyl. 4-stroke Diesel
4-cyl. 4-stroke Diesel
Aspiration and cooling
Suction engine, water-cooled
Suction engine, water-cooled
Suction engine, oil-cooled
Turbo, oil-cooled
Engine capacity
1718 cm3
2290 cm3
3110 cm3
3110 cm3
Constant rating [PRP]
14,8 kW
19,1 kW
27,6 kW
36,4 kW
Rpm/Regulation
1500/mechanical
1500/mechanical
1500/mechanical
1500/mechanical
Fuel/Tank capacity (litres)*1
Diesel/51
Diesel/51
Diesel/51
Diesel/51
Consumption/Running-time1
2,6 l/19,5 h
3,6 l/14 h
5,3 l/9,5 h
7,1 l/7 h
Cooling air volume m3/h
N/A
N/A
1800
2370
Start-up system/Batterie V/Ah E-Start 2 kW/12/45
E-Start 2 kW/12/70
E-Start 3 kW/12/70
E-Start 3 kW/12/70
Sound power level LWA2
96 dB(A)
96 dB(A)
92 dB(A)
92 dB(A)
Sound pressure level LPA3
71 dB(A)
71 dB(A)
67 dB(A)
67 dB(A)
Weight kg
470
514
916
918
Dimensions L x W x H in mm
1600 x 870 x 1072
1600 x 870 x 1072
2000 x 920 x 1300
2000 x 920 x 1300
Outfit Shockproof sockets
1 2 1 1
1 2 1 1
1 2 1 1
1 2 1 1
x x x x
230 CEE CEE CEE
V/16 A 230 V/16 A 400 V/16 A 400 V/32 A
x x x x
230 CEE CEE CEE
V/16 A 230 V/16 A 400 V/16 A 400 V/32 A
x x x x
230 CEE CEE CEE
V/16 A 230 V/16 A 400 V/32 A 400 V/63 A
x x x x
230 CEE CEE CEE
V/16 A 230 V/16 A 400 V/32 A 400 V/63 A
Analogue, manual control panel with control units, thermo magnetic automatic circuit breaker with 3-pole protection for 230/400 V, residual current device, oil suction pump (manual), crane loading device, optical fuel gauge Options not retrofit
Order No.
Emergency power supply 342 400 incl. preheating system, 1 x CEE 400 V socket
342 400
Electronic engine speed governor
342 400
342 400
342 001
342 001
Available accessories: Load transfer switch panel
343 012/E-US 20
343 000/E-US 32
343 001/E-US 45
343 002/E-US 60
Earth rod
343 304
343 304
343 304
342 304
1 2
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
BUILDING SITE GENERATORS
Undercarriages according to StVZO: One axle trailer FG 135 ST One axle trailer FG 135 HV
G E N E R AT O R S
ESE 20 DW-B
51
! Ideal for leasing and mobile Floodlight system e unit! generator in on
Transport securing
MOBILE
FLOODLIGHT SYSTEMS
Floodlight systems
Simple handling and safe transport
52 Base turns 360 degrees steplessly
EFA 950 S6 MK
ENDRESS floodlight systems turn the night into day. For optimal, bright illumination of building sites and many other places. Very versatile and flexible. Due to the top-mounted ENDRESS generator the flood light system does not require mains supply.
EFA 950 S6 MK Simple handling by crank. Set-up and extension in one go. Light pole turns 360 degrees steplessly. Self-locking crank winch. Low transportation height. Swivel-type special halogen flood lamps. Fully galvanized chassis acc. to highway code. Adjustable drawbar height. Extending stabilizers for high stability.
• • • • • • • •
EFA 850 S6 P Pneumatic aluminium telescopic pole, stepless extension. Internal helical cable for more operational safety. Light directly availably at site. Light pole turns 360 degrees steplessly. Maintenance-free anodized aluminium pole. swivel-type special halogen flood lamps. Fully galvanized chassis acc. to highway code. Adjustable drawbar height. Extending stabilizers for high stability.
EFA 650 S4, EFA 830 S4, EFA 830 S6, EFA S6 V Maintenance-free aluminum telescoping pole. Integrated drop arrest device. Simple handling by crank. Light pole turns 360 degrees steplessly. Self-locking crank winch. Swivel-type special halogen flood lamps. Fully galvanized chassis acc. to highway code. Adjustable drawbar height
• • • • • •
FLOODLIGHT SYSTEMS
• • • • • • • • •
•
EFA 850 S6 P
MOBILE
• • Extending stabilizers for high (except ESE 650 S4).
stability.
EFA 650 S4
53 NEW
NEW
Type
EFA 650 S4
EFA 830 S4
EFA 830 S6
EFA 850 S6 V
EFA 850 S6 P
EFA 950 S6 MK
Order No.
716 200
716 260
716 280
716 240
716 290
716 230
Light output
4 x 1500 W
4 x 1500 W
6 x 1500 W
6 x 1500 W
6 x 1500 W
6 x 1500 W
3 x switchable
3 x switchable
3 x switchable
3 x switchable
3 x switchable
3 x switchable
Max. spotlight height
6,5 m
8,3 m
8,3 m
8,5 m
8,5 m
9,5 m
Min. transport height
2,68 m
2,55 m
2,55 m
2,55 m
2,75 m
2,.25 m
Lamp poles Pole
continuously 360° rotatable continuously 360° rotatable continuously 360° rotatable continuously 360° rotatable continuously 360° rotatable continuously 360° rotatable
Version
Alu-teleskopic pole
Alu-teleskopic pole
Alu-teleskopic pole
Alu-teleskopic pole
Alu-teleskopic pole
Steel mast/folding
Function
mech./hand crank
mech./hand crank
mech./hand crank
pneumatic
pneumatic
mech./hand crank
Undercarriage according to StVZO
FG 75 LM
FG 100 LM
FG 160 LM
FG 2500 LM Tandem
FG 160 LM
FG 160 LM
Width in mm
1600
1540
1650
1720
1650
1650
Length over all in mm
3400
4230
5150
5450
5150
5150
Tyres
13’’
13’’
14’’
15’’
14’’
14’’
Drawbar
rigid
height adjustable
height adjustable
height adjustable
height adjustable
height adjustable
Overrun brake
non-braked
yes
yes
yes
yes
yes
Total weight allowed kg
750
1000
1600
2500
1600
1600
Supp. weight allowed kg
50
75
75
100
75
75
Recommended generators
ESE 1008 DBS ES Silent
ESE 15 DW-B
ESE 20 DW-B
ESE 30 DL/MS
ESE 30 DW-B
ESE 20 DW-B
ESE ESE ESE ESE
ESE 40 DL/MS ESE 65 DW/MS ESE 80 DW/MS
ESE 40 DW-B
ESE ESE ESE ESE
ESE 1308 DBS ES Silent ESE 1204 DHS ES ISO Diesel
30 40 15 20
DL-B DL-B DW/MS DW/MS
30 40 15 20
DL-B DL-B DW/MS DW/MS
SUPPLY SYSTEMS
P OW E R S U P P LY SYS T E M S
Power supply systems 15 - 600 kVA
54
All ENDRESS generators of type series AS and MS meet the new directive Appendix VIII - 2000/14/EC concerning noise emission.
Only strong components will make powerful generators! For reasons of technical competence, ENDRESS employs only the high quality industrial engines from DEUTZ and VOLVO-Penta as well as quality alternators from STAMFORD and Mecc Alte.
Profi-Power package
Oil and water cooled 4-stroke industrial diesel engines secure the professional drive. Due to low fuel and oil consumption as well as the small maintenance effort they are very economical in continuous application. ENDRESS power supply installations are equipped with high-quality, tropicalized* STAMFORD generators** as per VDE 0530 - insulation class H - and are designed for maximum output under the toughest of conditions. Perfect also for leasing. * For safe application in countries with high ambient temperature and air humidity. **Except ESE 15 series
One key system, suitable at all doors, ignition lock and fuel tank cap.
SUPPLY SYSTEMS
P OW E R S U P P LY SYS T E M S
Removable cover and large doors for easy cleaning
55 Easy to access, large air filter with exchangeable filter elements.
as standard:
Large diesel filter with water separator and drain plug.
Battery main switch separates the battery from all components of the generator.
Manual oil drain pump for simple and quick oil change.
SUPPLY SYSTEMS
P OW E R S U P P LY SYS T E M S
Manual, analogical control panel ENDRESS power generating systems supply constant power, which makes them versatile in use, e.g., for irrigation systems, conveyor belts, cranes, ramming work as well as for building sites and mobile applications. There is no need to connect an automatic emergency supply.
Manual control panel The set is started manually by a STARTSTOP key-operated switch. The set can be stopped instantly at the emergency stop button in case of danger. An automatic control unit for the engine and generator functions, 3-pole circuit breaker (4-pole breaker optional) and a differential protection switch are standard for the MS series. Also part of the delivery is a power terminal board for full power withdrawal. A socket combination is available as optional extra. For more information, read on p. 66-67.
56
ENDRESS power supply installations meet the EU machine and low voltage directives as well as the requirements of DIN VDE 0100. Engine output: Continuous output to ISO 3046 (ICN 2) measured at 300 m altitude and +25°C outdoor temperature under variable load. All models meet the German emission control requirements.
Analog displays
• Voltmeter* • Ammeter* • Frequency meter • Run hour meter • Fuel level • Oil pressure • Engine temperature
*3-phase measurement with changeover switch
Engine protection functions with alarm Low oil pressure Overtemperature Fuel reserve Battery charge fault
• • • •
Control functions START-STOP switch with key Emergency STOP button
• •
Generator protection functions 3-pole main circuit breaker RCD
• •
Power supply system Terminal board Optional: Profi-Power-Package Socket outlet combination Battery main switch 3-way fuel cock Grounding rod
• •
(available in series ESE 220 and earlier)
Engine protection functions with cut-off Low oil pressure Overtemperature Fuel reserve Battery charge fault
• • • •
• Optional: Socket outlet combination in series ESE 310 and higher
Automatic control panel The control panel is mounted on the base frame (open design) or integrated in the noise cover. It consists of the automatic control of engine and generator functions. Faults are signaled visually and audibly. The circuit breaker (3-pole standard, 4-pole optional) and differential protection are part of the supply. The automatic control panel is prepared for connection of a changeover contactor. (E-US available as accessory item). Integrated functions and components: Measures and displays the following parameters (instantaneous values) by digital display and LED.
Programming switch Mode selection 1 Automatic Test T 2 Automatic standard mode A 3 Locked mode Electronic system disabled, required for maintenance
4 Consumer mains supply CR 5 Manual Start enable for manual start-up
6 Manual control of the supply of the consumer by the generator CG
Digital display:
Warnings (W) and switch-offs (S)
• Mains and generator voltages • 3-phase generator current • Generator frequency • Output (kVA, kW, kVAr, cos (phi) • Battery charge voltage and charge
• Low oil (W + S) • Overtemperature (W + S) • Failed start (W) • Battery over- and undertvoltage (W) • External STOP (S) • Under- and overfrequency (W + S) • Fuel reserve (W + S) • ELCB (S) • Overload kVA (S) • Shirt circuit (S) • Over- and undervoltage (W + S) • Battery charge fault (W + S)
• • • • • • •
current Speed Fuels reserve Oil pressure Temperature Run hours, maintenance intervals Starting attempts State and alarm description
LEDs Mains availability Mains contactor ON Generator contactor ON Differential protection tripped Generator service Engine alarm status Battery charger ON Battery ON Microcontroller operation Fuel pump filling Engine start Engine stop
• • • • • • • • • • • •
SUPPLY SYSTEMS
ENDRESS emergency generator systems, together with the automatic control unit, automatically restore the power supply if the mains supply fails. The mains voltage is monitored automatically and if a drop is detected in one or several phases, the engine starts automatically - manual starting is also possible.
P OW E R S U P P LY SYS T E M S
Automatic control panel
57
SUPPLY SYSTEMS
P OW E R S U P P LY SYS T E M S
DEUTZ oil- and water-cooled engines 15 - 40 kVA The ESE 15 and ESE 20 model series have compact water-cooled DEUTZ industrial engines of the D2009 series. Little maintenance and high quality are typical of these engines which are in worldwide use. The ESE 30 and ESE 40 series are equipped with oil-cooled DEUTZ
engines and turbocharger (depending on model). These oil-cooled diesel engines are very reliable and long-lived. Low fuel and oil consumption make them very economical in continuous service.
STAMFORD ensure the parallel operation of ohmic and inductive consumers. Designed for maximum output under the toughest of conditions and made according to VDE 0530, insulation class H.
The brushless synchronous generators with electronic regulation from Mecc Alte and
58
ESE 80 DW
Serial equipment at a glance: Liquid collection pan in AS/MS series models to ensure that no operating fluid is spilled. Engine prewarming system in models with automatic emergency supply. for reliable starting little wear saves fuel low emission level
• •
• •
ESE 15 15,0/12,0 14,3/11,4 Mecc Alte ECO 32 L/4 synchronous/class H 400 V 3~/230 V 1~ 20,6 A 3~/0,8 50 Hz electronic (± 1,5)
ESE 20 21,1/16,8 20,1/16,1 STAMFORD BCI 184 E synchronous/class H 400 V 3~/230 V 1~ 29,0 A 3~/0,8 50 Hz electronic (± 1,5)
ESE 30 30,0/24,0 29,0/32,2 STAMFORD BCI 184 F synchronous/class H 400 V 3~/230 V 1~ 41,9 A 3~/0,8 50 Hz electronic (± 1,5)
ESE 40 41,2/33,0 39,3/31,4 STAMFORD BCI 184 J synchronous/class H 400 V 3~/230 V 1~ 56,7 A 3~/0,8 50 Hz electronic (± 1,5)
Engine type Version Intake mode/Cooling system Engine capacity Constant rating [PRP] kW Rpm/Regulation Cooling air volume m3/h Start-up system/Battery V/Ah
DEUTZ D2009 L03 3-cyl. 4-stroke Diesel Suction engine/water-cooled 1718 cm3 14,8 1500/mechanical N/A E-Start 2 kW/12/45
DEUTZ D2009 L04 4-cyl. 4-stroke Diesel Suction engine/water-cooled 2290 cm3 19,1 1500/mechanical N/A E-Start 2 kW/12/70
DEUTZ F4M 2011 4-cyl. 4-stroke Diesel Suction engine/oil-cooled 3110 cm3 27,6 1500/mechanical 1800 E-Start 3 kW/12/70
DEUTZ BF4M 2011 4-cyl. 4-stroke Diesel Turbor/oil-cooled 3110 cm3 36,4 1500/mechanical 2370 E-Start 3 kW/12/70
Type series DW/DL
Model: Opfen version incl. automatic control panel, preheating system and terminal box
Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Weight kg Dimensions L x W x H in mm
ESE 15 DW* 330 200 Diesel/51 2,6 l/19,5 h 410 1600 x 870 x 1000
Outfit
Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main fuse, emergency stop switch, residual current device, engine preheating system, connection device for power supply and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch, battery pre-charged dryly.
* ESE 15 DW * ESE 15 DW
ESE 20 DW* 330 201 Diesel/51 3,6 l/14 h 445 1600 x 870 x 1000
ESE 30 DL 330 202 Diesel/90 5,3 l/17 h 714 1800 x 750 x 1570
ESE 40 DL 330 203 Diesel/90 6,9 l/13 h 761 1800 x 750 x 1570
max. output [LTP] kVA/kW 13,8/11,0 · constant rating [PRP] kVA/kW 13,0/10,4 · alternator type: LINZ E1S 13 M 4-13 kVA · regulation: compound max. output [LTP] kVA/kW 20,1/16,1 · constant rating [PRP] kVA/kW 19,0/15,2 · alternator type: LINZ E1S 13 M 4-19 kVA · regulation: compound
Type series AS
Model: Closed version with automatic control panel, preheating system, terminal box and leak proof tray
Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Sound power level LWA2 Sound pressure level LWA3 Weight kg Dimensions L x W x H in mm
ESE 15 DW/AS 331 200 Diesel/55 2,8 l/28,5 h 91 dB(A) 66 dB(A) 720 1800 x 830 x 1295
Outfit
Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main fuse, emergency stop switch, residual current device, engine preheating system, connection device for power supply and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch, leak proof tray, oil suction pump (manual), crane loading devive, soundproof canopy, battery pre-charged dryly.
Type series MS
ESE 20 DW/AS 331 201 Diesel/55 3,9 l/20,5 h 91 dB(A) 66 dB(A) 785 1800 x 830 x 1295
ESE 30 DL/AS 331 202 Diesel/120 5,6 l/21,5 h 92 dB(A) 67 dB(A) 992 2225 x 1100 x 1290
ESE 40 DL/AS 331 203 Diesel/120 7,5 l/16 h 92 dB(A) 67 dB(A) 1064 2225 x 1100 x 1290
Model: Closed version with key start, analogue control panel, terminal box, soundproof canopy and leak proof tray
Type Order No.
ESE 15 DW/MS 332 200
Outfit
Manual control panel with control unit, main switch ON/OFF, main fuse, emergency stop switch, residual current device, engine preheating system, connection device for power supply and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch, terminal strip for full collection of power, leak proof tray, oil suction pump (manual), crane loading device, soundproof canopy, battery pre-charged dryly.
Load transfer switch Order No. 1 2
343 012/E-US 20
ESE 20 DW/MS 332 201
343 000/E-US 32
ESE 30 DL/MS 332 202
343 001/E-US 45
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
ESE 40 DL/MS 332 203
343 002/E-US 60
SUPPLY SYSTEMS
General specifications Type Max. output [LTP] kVA/kW Constant rating [COP] kVA/kW Alternator type Version/Insulation Nominal voltage Nominal current Frequency Regulation
P OW E R S U P P LY SYS T E M S
MS version Optional: Profi-Power-Package and galvanized base frame
59
SUPPLY SYSTEMS
P OW E R S U P P LY SYS T E M S
DEUTZ water-cooled engines 60 - 540 kVA DEUTZ water-cooled industrial engines with 4- and 6-cylinder in-line engines of the 2012 and 1013 series are used up to model series ESE 220. Engines with turbocharger and turbocharger/charge air cooler ensure professional drive. The progressive high-pressure injection system and the individual injection pumps reduce the fuel consumption of the engines. DEUTZ water-cooled V8 industrial engines of series 1015 are fitted in the model series ESE 530 and higher series. Electronic engine control ensures optimal steady-state behavior under conditions of peak load (max. 0.3 s). Direct injection, 4-valve technology and environmentally compatible combustion not only improve the operating characteristics but also reduce the operating costs.
60
The brushless synchronous generators with electronic control from Mecc Alte and STAMFORD ensure the parallel operation of ohmic and inductive consumers. Designed for maximum output under the toughest of conditions and made according to VDE 0530, insulation class H.
MS version Optional: Profi-Power-Package and galvanized base frame
General specifications Type Max. output [LTP] kVA/kW Constant rating [COP] kVA/kW Alternator type Version/Insulation Nominal voltage Nominal current/cos (phi) Frequency Regulation
ESE 65 63,0/50,4 57,7/46,1 STAMFORD UCI 224 E synchronous/class H 400 V 3~/230 V 1~ 83 A 3~/0,8 50 Hz electronic (± 1,5)
ESE 80 78,5/62,8 74,1/59,3 STAMFORD UCI 224 F synchronous/class H 400 V 3~/230 V 1~ 107 A 3~/0,8 50 Hz electronic (± 1,5)
ESE 110 108/86,5 102/82,0 STAMFORD UCI 274 C synchronous/class H 400 V 3~/230 V 1~ 147 A 3~/0,8 50 Hz electronic (± 1,5)
Engine type Version Intake mode/Cooling system Engine capacity Constant rating [PRP] kW Rpm/Regulation Cooling air volume Start-up system/Batterie V/Ah
DEUTZ BF4M 2012-G2 4-cyl. 4-stroke Diesel Turbo/water-cooled 4040 cm3 52,0 1500/mechanical 5400 E-Start 3 kW/12/95
DEUTZ BF4M 2012 C 4-cyl. 4-stroke Diesel Tb-Intercool/water-cooled 4040 cm3 66,1 1500/mechanical 4680 E-Start 3 kW/12/95
DEUTZ BF4M 1013 EC 4-cyl. 4-stroke Diesel Tb-Intercool/water-cooled 4760 cm3 91,1 1500/mechanical 6120 E-Start 3,1 kW/12/145
Type series DW
Model: Open version incl. automatic control panel, preheating system a
Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Weight kg Dimensions L x W x H in mm
ESE 65 DW 330 204 Diesel/240 10,2 l/23,5 h 865 2200 x 1000 x 1620
Outfit
Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main battery pre-charged dryly.
Serial equipment at a glance: Leak proof tray in AS/MS series models to ensure that no operating fluid is spilled. Engine pre-heating system in models with automatic emergency supply. for reliable starting saves fuel little wear low emission level
• • • •
ESE 80 DW 330 205 Diesel/240 11,7 l/20,5 h 945 2200 x 1000 x 1620
ESE 110 DW 330 206 Diesel/240 16,5 l/14,5 h 1326 2200 x 1000 x 1620
Type series AS
Model: Closed version with automatic control panel, preheating system,
Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Sound power level LWA2 Sound pressure level LPA3 Weight kg Dimensions L x W x H in mm
ESE 65 DW/AS 331 204 Diesel/340 10,2 l/33,4 h 96 dB(A) 71 dB(A) 1300 2710 x 1180 x 1535
Outfit
Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main terminal box for full collection of power, leak proof tray, oil suction pump (manual), crane loading de
Type series MS
Model: Closed version with key start, analogue control panel, terminal b
Type Order No.
ESE 65 DW/MS 332 204
Outfit
Manual control panel with control unit, main switch ON/OFF, main fuse, emergeny stop switch, resid leak proof tray, oil suction pump (manual), crane loading device, soundproof canopy, battery pre-ch
Load transfer switch Order No. 1 2
343 003/E-US 90
ESE 80 DW/AS 331 205 Diesel/340 11,7 l/29 h 96 dB(A) 71 dB(A) 1460 2710 x 1180 x 1535
ESE 80 DW/MS 332 205
343 004/E-US 110
ESE 110 DW/AS 331 206 Diesel/340 16,5 l/20 h 96 dB(A) 72 dB(A) 1900 3000 x 1150 x 1680
ESE 110 DL/MS 332 206
343 005/E-US 200
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
ESE 170 167/134 159/127 STAMFORD UCI 274 E synchronous/class H 400 V 3~/230 V 1~ 230 A 3~/0,8 50 Hz electronic (± 1,5)
ESE 195 194/155 186/149 STAMFORD UCI 274 G synchronous/class H 400 V 3~/230 V 1~ 269 A 3~/0,8 50 Hz electronic (± 1,5)
ESE 220 220/176 208/166 STAMFORD UCI 274 H synchronous/class H 400 V 3~/230 V 1~ 300 A 3~/0,8 50 Hz electronic (± 1,5)
ESE 530 528/422 459/367 Mecc Alte ECO 40 3S synchronous/class H 400 V 3~/230 V 1~ 663 A 3~/0,8 50 Hz electronic (± 1,5)
ESE 560 546/437 509/407 Mecc Alte ECO 40 3S synchronous/class H 400 V 3~/230 V 1~ 735 A 3~/0,8 50 Hz electronic (± 1,5)
DEUTZ BF6M 1013 E 6-cyl. 4-stroke Diesel Turbo/water-cooled 7150 cm3 117,8 1500/mechanical 9000 E-Start 3,1 kW/12/145
DEUTZ BF6M 1013 EC 4-cyl. 4-stroke Diesel Tb-Intercool/water-cooled 7150 cm3 138,1 1500/mechanical 10800 E-Start 3,1 kW/12/145
DEUTZ BF6M 1013 FC G2 4-cyl. 4-stroke Diesel Tb-Intercool/water-cooled 7150 cm3 161,6 1500/electronic 7377 E-Start 3,1 kW/24/2 x 145
DEUTZ BF6M 1013 FC G3 4-cyl. 4-stroke Diesel Tb-Intercool/water-cooled 7150 cm3 178,6 1500/electronic 8852 E-Start 3,1 kW/24/2 x 145
DEUTZ BF8M 1015 C G2 V 8-cyl. 4-stroke Diesel Tb-Intercool/water-cooled 15900 cm3 391,3 1500/electronic 24120 E-Start 5,4 kW/24/2 x 200
DEUTZ BF8M 1015 CP V 8-cyl. 4-stroke Diesel Tb-Intercool/water-cooled 15900 cm3 433,9 1500/electronic 33120 E-Start 5,4 kW/24/2 x 200
ESE 170 DW 330 208 Diesel/250 24,5 l/10 h 1615 2600 x 1000 x 1620
ESE 195 DW 330 209 Diesel/410 43,7 l/9 h 1980 2650 x 1100x 1965
ESE 220 DW 330 210 Diesel/410 49,2/8 h 2030 2650 x 1100 x 1965
ESE 530 DW 330 211 Diesel/636 74,8 l/8,5 h 3860 3300 x 1800 x 2135
ESE 560 DW 330 212 Diesel/636 84,8 l/7,5 h 3910 3300 x 1800 x 2135
and terminal box ESE 145 DW 330 207 Diesel/250 23 l/11 h 1545 2200 x 1000 x 1600
fuse, emergeny stop switch, residual current device, engine preheating system, connection device for current collection and load transfer switch directly at main switch, fuse protection by power switch,
, terminal box and leak proof tray ESE 145 DW/AS 331 207 Diesel/340 23 l/14,5 h 97 dB(A) 72 dB(A) 2180 3400 x 1250 x 1680
ESE 170 DW/AS 331 208 Diesel/340 24,5 l/14 h 97 dB(A) 72 dB(A) 2250 3400 x 1250 x 1680
ESE 195 DW/AS 331 209 Diesel/340 32,9 l/10,5 h 97 dB(A) 72 dB(A) 2700 3400 x 1250 x 2070
ESE 220 DW/AS 331 210 Diesel/340 36,8 l/9 h 97 dB(A) 72 dB(A) 2750 3400 x 1250 x 2070
ESE 530 DW/AS 331 211 Diesel/636 74,8 l/8,5 h 98 dB(A) 73 dB(A) 5130 4200 x 1860 x 2250
ESE 560 DW/AS 331 212 Diesel/636 84,8 l/7,5 h 104 dB(A) 73 dB(A) 5155 4200 x 1860 x 2250
fuse, emergeny stop switch, residual current device, engine preheating system, connection device for current collection and load transfer switch directly at main switch, fuse protection by power switch, evice, soundproof canopy, battery pre-charged dryly
box, soundproof canopy and leak proof tray ESE 145 DW/MS 332 207
ESE 170 DW/MS 332 208
ESE 195 DW/MS 332 209
ESE 220 DW/MS 332 210
dual current device, engine preheating system, connection device for current collection and load transfer switch directly at main switch, fuse protection by power switch terminal strip for fully collection of power, arged dryly 343 005/E-US 200
343 006/E-US 325
343 006/E-US 325
343 006/E-US 325
343 0109/E-US 1000
343 010/E-US 1000
SUPPLY SYSTEMS
ESE 145 142/113 135/108 STAMFORD UCI 274 E synchronous/class H 400 V 3~/230 V 1~ 195 A 3~/0,8 50 Hz electronic (± 1,5)
P OW E R S U P P LY SYS T E M S
AS version Optional: Socket outlet combination
61
SUPPLY SYSTEMS
P OW E R S U P P LY SYS T E M S
VOLVO-PENTA water-cooled engines 310 - 600 kVA VOLVO-PENTA water-cooled 4-stroke 6-cyliner in-line engines the powerful diesel engines with turbocharger/charge air cooler provide professional drive. The industrial engines with direct injection and optimized combustion respond quickly in cold weather and have low exhaust emission and high economy of operation.
The electronic engine control ensures optimal steady-state behavior under conditions of peak load (max. 0.3 s).
put under the toughest of conditions and made according to VDE 0530, insulation class H.
Mecc Alte generator, the brushless highperformance synchronous generator with electronic control, ensures the parallel operation of ohmic and inductive consumers. Designed for maximum out-
62
Serial equipment at a glance:
• •
Leak proof tray in AS series models to ensure that no operating fluid is spilled. Engine pre-heating system in models with automatic emergency supply. for reliable starting little wear saves fuel low emission level
• •
ESE 275 275/220 252/202 Mecc Alte ECO 38 1L synchronous/class H 400 V 3~/230 V 1~ 363 A 3~/0,8 50 Hz electronic (± 1,5)
ESE 330 330/264 315/264 Mecc Alte ECO 38 2L synchronous/class H 400 V 3~/230 V 1~ 454 A 3~/0,8 50 Hz electronic (± 1,5)
ESE 415 414/331 378/302 Mecc Alte ECO 40 31 synchronous/class H 400 V 3~/230 V 1~ 546 A 3~/0,8 50 Hz electronic (± 1,5)
Engine type Version Intake mode/Cooling system Engine capacity Constant rating [PRP] kW Rpm/Regulation Cooling air volume m3/h Start-up system/Batterie V/Ah
VOLVO TAD 734 GE 6-cyl. 4-stroke Diesel Tb-intercool/water-cooled 7150 cm3 216 1500/electronic N/A E-Start 5,4 kW/24/2 x 155
VOLVO TAD 941 GE 6-cyl. 4-stroke Diesel Tb-intercool/water-cooled 9360 cm3 279 1500/electronic 17410 E-Start 5,4 kW/24/2 x 200
VOLVO TAD 1241 GE 6-cyl. 4-stroke Diesel Tb-intercool/water-cooled 12130 cm3 323 1500/electronic 16225 E-Start 6 kW/24/2 x 155
Type series VW
Model: Open version incl. automatic control panel, preheating system and terminal box
Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Weight kg Dimensions L x W x H in mm
ESE 275 VW 330 224 Diesel/636 39 l/16 h 2108 2950 x 1300 x 1800
Outfit
Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main fuse, emergency stop switch, residual current device, engine preheating system, connection device for current collection and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch, battery pre-charged drylyn
ESE 330 VW 330 215 Diesel/636 48,9 l/13 h 2600 3300 x 1400 x 1887
ESE 415 VW 330 216 Diesel/636 57,8 l/11 h 3050 3300 x 1400 x 1917
Type series AS
Model: Closed version with automatic control panel, preheating system, terminal box and leak proof tray
Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Sound power level LWA2 Sound pressure level LPA3 Weight kg Dimensions L x W x H in mm
ESE 275 VW/AS 331 224 Diesel/636 39 l/16 h 97 dB(A) 72 dB(A) 2726 3550 x 1360 x 2016
Outfit
Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main fuse, emergeny stop switch, residual current device, engine preheating system, connection device for current collection and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch, leak proof tray, oil suction pump (manual), crane loading device, soundproof canopy, battery pre-charged dryly
ESE 330 VW/AS 331 215 Diesel/636 48,9 l/13 h 97 dB(A) 72 dB(A) 3200 3950 x 1460 x 2095
ESE 415 VW/AS 331 216 Diesel/636 74,8 l/8,5 h 97 dB(A) 72 dB(A) 3675 3950 x 1460 x 2095
Load transfer switch Order No. 1 2
343 007/E-US 400
343 008/E-US 500
343 009/E-US 700
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
SUPPLY SYSTEMS
General specifications Type Max. output [LTP] kVA/kW Constant rating [PRP] kVA/kW Alternator type Building class/Insulation Nominal voltage Nominal current/cos (phi) Frequency Regulation
P OW E R S U P P LY SYS T E M S
AS version Optional: Socket outlet combination
63
SUPPLY SYSTEMS
P OW E R S U P P LY SYS T E M S
VOLVO-PENTA water-cooled engines 440 - 600 kVA
64
AS version Optional: Socket outlet combination
General specifications Type Max. output [LTP] kVA/kW Constant rating [PRP] kVA/kW Alternator type Building class-/Insulation Nominal voltage Nominal current/cos (phi) Frequency Regulation
ESE 450 437/350 411/329 Mecc Alte ECO 40 1S synchronous/class H 400 V 3~/230 V 1~ 593 A 3~/0,8 50 Hz electronic (± 1,5)
ESE 510 507/406 461/369 Mecc Alte ECO 40 3S synchronous/class H 400 V 3~/230 V 1~ 665 A 3~/0,8 50 Hz electronic (± 1,5)
ESE 560 546/437 505/404 Mecc Alte ECO 40 3S synchronous/class H 400 V 3~/230 V 1~ 729 A 3~/0,8 50 Hz electronic (± 1,5)
ESE 590 601/481 571/457 Mecc Alte ECO 40 1L synchronous/class H 400 V 3~/230 V 1~ 824 A 3~/0,8 50 Hz electronic (± 1,5)
Engine type Version Intake mode/Cooling system Engine capacity Constant rating [PRP] kW Rpm/Regulation Cooling air volume m3/h Start-up system/Batterie V/Ah
VOLVO TAD 1242 GE 6-cyl. 4-stroke Diesel Tb-intercool/water-cooled 12130 cm3 352 1500/electronic 19918 E-Start 6 kW/24/2 x 155
VOLVO TAD 1640 GE 6-cyl. 4-stroke Diesel Tb-intercool/water-cooled 16120 cm3 393 1500/electronic 16820 E-Start 7 kW/24/2 x 200
VOLVO TAD 1641 GE 6-cyl. 4-stroke Diesel Tb-intercool/water-cooled 16120 cm3 430 1500/electronic 21541 E-Start 7 kW/24/2 x 200
VOLVO TAD 1642 GE 6-cyl. 4-stroke Diesel Tb-intercool/water-cooled 16120 cm3 485 1500/electronic 21541 E-Start 7 kW/24/2 x 200
Type series VW
Model: Open version incl. automatic control panel, preheating system and terminal box
Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Weight kg Dimensions L x W x H in mm
ESE 450 VW 330 217 Diesel/636 63,6 l/10 h 3050 3300 x 1400 x 1197
Outfit
Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main fuse, emergeny stop switch, residual current device, engine preheating system, connection device for current collection and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch, battery pre-charged dryly
ESE 510 VW 330 218 Diesel/636 66,9 l/9,5 h 3620 3500 x 1500 x 2120
ESE 560 VW 330 219 Diesel/636 74,8 l/8,5 h 3620 3500 x 1500 x 2120
ESE 590 VW 330 220 Diesel/636 84,8 l/7,5 h 3850 3500 x 1500 x 2120
Type series AS
Model: Closed version with automatic control panel, preheating system, terminal box and leak proof tray
Type Order No. Fuel/Tank capacity (litres) Consumption/Running-time1 Sound power level LWA2 Sound pressure level LPA3 Weight kg Dimensions L x W x H in mm
ESE 450 VW/AS 331 217 Diesel/636 63,6 l/10 h 97 dB(A) 72 dB(A) 3675 3950 x 1460 x 2095
Outfit
Automatic control panel with control unit and integrated battery charger, main switch ON / OFF, main fuse, emergeny stop switch, residual current device, engine preheating system, connection device for current collection and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch, leak proof tray, oil suction pump (manual), crane loading device, soundproof canopy, battery pre-charged dryly
Load transfer switch Order No. 1 2
343 009/E-US 700
ESE 510 VW/AS 331 218 Diesel/636 66,9 l/9,5 h 98 dB(A) 73 dB(A) 4500 4400 x 1560 x 2250
343 010/E-US 700
ESE 560 VW/AS 331 219 Diesel/636 74,8 l/8,5 h 105 dB(A) 80 dB(A) 4500 4400 x 1560 x 2250
343 010/E-US 1000
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation. Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
ESE 590 VW/AS 331 220 Diesel/636 84,8 l/7,5 h 105 dB(A) 80 dB(A) 4890 4400 x 1560 x 2250
343 010/E-US 1000
*with consideration of the charge state of the diesel engine
Machines with no-load fans rotary pumps circular saws
< < < < < < < < < < Machines < with load fans with high < flywheel moment < compressors < < conveyors < construction < machinery < Machines with < heavy starting < < elevators < heavy < conveyors < construction < machinery < < All above < < mentioned < machines < but with < star-delta< connection < <