used for two different applications: 1. Coupling of Surge and EFT/burst pulses as
per. IEC 61000-4-4 Ed.2 and IEC 61000-4-5 Ed.2 onto single phase or ...
Product Information Combined Coupling/Decoupling Networks for Burst and Surge CNI501/CNI 503 The coupling/decoupling network type CNI 501/503 is used for two different applications: 1.
Coupling of Surge and EFT/burst pulses as per IEC 61000-4-4 Ed.2 and IEC 61000-4-5 Ed.2 onto single phase or three-phase power mains supply lines.
2.
Decoupling of the transient pulses from the public power mains supply to avoid disturbance of other equipment connected to the mains.
The following instruments are available as standard: Model
Description
AC supply 50/ 60 Hz
DC supply
CNI 501 CNI 501 S1 CNI 501 S4
4.4kV Coupler/Decoupler 4.4kV Coupler/Decoupler 10kV Coupler/Decoupler
Single phase 250V/ 32A Single phase 250V/100A Single phase 250V/ 16A
48V / 32A 48V / 100A 250V / 10A
CNI 503 A CNI 503 A2 CNI 503 A3 CNI 503 A4
4.4kV Coupler/Decoupler 4.4kV Coupler/Decoupler 4.4kV Coupler/Decoupler 4.4kV Coupler/Decoupler
3 - Phase 3x440V / 16A 3 - Phase 3x440V / 32A 3 - Phase 3x440V / 63A 3 - Phase 3x440V / 100A
250V / 250V / 250V / 250V /
16A 32A 63A 100A
CNI 503 B5 CNI 503 B7 CNI 503 B8 CNI 503 B9
6.6kV Coupler/Decoupler 6.6kV Coupler/Decoupler 6.6kV Coupler/Decoupler 6.6kV Coupler/Decoupler
3 - Phase 3x440V / 16A 3 - Phase 3x440V / 32A 3 - Phase 3x440V / 63A 3 - Phase 3x440V / 100A
250V / 250V / 250V / 250V /
16A 32A 63A 100A
CNI 503 A10 CNI 503 A12 CNI 503 A13 CNI 503 A14
8kV Coupler/Decoupler 8kV Coupler/Decoupler 8kV Coupler/Decoupler 8kV Coupler/Decoupler
3 - Phase 3x440V / 16A 3 - Phase 3x440V / 32A 3 - Phase 3x440V / 63A 3 - Phase 3x440V / 100A
250V / 250V / 250V / 250V /
16A 32A 63A 100A
CNI 503 A16 CNI 503 A18 CNI 503 A19 CNI 503 A20
10kV Coupler/Decoupler 10kV Coupler/Decoupler 10kV Coupler/Decoupler 10kV Coupler/Decoupler
3 - Phase 3x440V / 16A 3 - Phase 3x440V / 32A 3 - Phase 3x440V / 63A 3 - Phase 3x440V / 100A
250V / 250V / 250V / 250V /
16A 32A 63A 100A
Note: -
The CNI 503 A3/A4, CNI 503 B8/B9,CNI 503 A13/A14 and CNI 503 A19/A20 are designed for direct rack mounting only! The units can also be used for ac power line surge as per ANSI IEEE C62.41. This must be indicated on the order sheet.
EM TEST AG CH - 4153 Reinach BL URL: www.emtest.com
Tel: +41 61 717 91 91 Fax: +41 61 717 91 99 e-mail:
[email protected]
Data sheet: cni503.doc Version: 1.08 / 13.04.07 Replace: 1.07 / 01.11.06
St 1/2
Product Information Combined Coupling/Decoupling Networks for Burst and Surge CNI501/CNI 503
The following coupling modes are available: For IEC 61000-4-5 Surge Test Line to Line with a 2Ω source impedance Line(s) to PE with a 12Ω source impedance
L to N or + to All combinations
For IEC 61000-4-4 EFT/burst Test Line(s) to Reference Ground
All combinations
The CNI 501/503 can be used together with the following generators: For Surge VCS 500M TSS 500M2F UCS 500M4 UCS 500M6 For EFT/burst EFT 500/500M4 EFT 500M8 EFT 800 UCS 500M4 UCS 500M6
1.2/50µs - 8/20µs 0.5µs/100kHz Ring Wave 10µs 1.2/50µs - 8/20µs 1.2/50µs - 8/20µs
up to 10,000V as per IEC 61000-4-5 up to 6,000V as per ANSI/IEEE up to 2,500V as per FCC part 68 up to 4,000V up to 6,600V
5/50ns 5/50ns 5/50ns 5/50ns 5/50ns
up to 4,400V up to 7,000V up to 8,000V up to 4,400V up to 5,500V
For more detailed information see the brochures of the individual generators.
EM TEST AG CH - 4153 Reinach BL URL: www.emtest.com
Tel: +41 61 717 91 91 Fax: +41 61 717 91 99 e-mail:
[email protected]
Data sheet: cni503.doc Version: 1.08 / 13.04.07 Replace: 1.07 / 01.11.06
St 2/2