PVC Cement - Centaur PVC

50 downloads 533 Views 2MB Size Report
Centaur PVC solvent cement is made with the highest quality materials and meets or exceeds ASTM SPEC. D. 2564. All information provided is based on our  ...
High Standards

AVERAGE NUMBER OF JOINTS PER QUART

Centaur PVC solvent cement is made with the highest quality materials and meets or exceeds ASTM SPEC. D 2564. All information provided is based on our laboratory testing, independent laboratory test results, and actual field experience. Properly used, this material will perform in accordance with applicable standards listed below.

NSF International is an organization that provides standards development, product certification, auditing, education and risk management for public health and safety.

Low VOC: Volatile Organic Compounds Organic chemical compounds with significant vapor pressures and which can affect the environment and human health.

ASTM is a globally recognized leader in the development and delivery of international voluntary consensus standards

Uniform Plumbing Code (UPC) is a model code developed by the International Association of Plumbing and Mechanical Officials (IAPMO) to govern the installation and inspection of plumbing systems as a means of promoting the public's health, safety and welfare

ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence.

Choosing The Right Product

PIPE DIAMETERS

NUMBER OF JOINTS

1/2" 20mm

350

3/4" 25mm

300

1" 32mm

200

1-1/2" 50mm

120

2" 63mm

80

3" 90mm

50

4" 110mm

40

6" 160mm

20

8" 200mm

6

10" 250mm

3

12" 315mm

2

14" 380mm

1

18" 450mm

1/2

PVC Cement

For Assistance with selecting the right Centaur product for your application, please refer to the chart below. Product Description Type

Series

Color

Primers

PP32

Purple

Cleaners

C32

Clear

Specialty

AT32

Clear

Medium Body

G32

Gray

Regular Body

CMT

Clear

Pipe Size mm

20

25

32

40

50

63

75

90

110

160

200

250

315

355

600

800

in

1/2

3/4

1

1-1/4

1-1/2

2

2-1/2

3

4

6

8

10

12

14

24

30

Legend Schedule 40



Economically Formulated

Schedule 80



Fast Setting



Wide Range of Applications



Independently and Laboratory Tested

Centaur East Division Scan for PVC Website

635 Northwest Enterprise Dr. Port St. Lucie, FL 34986 ph: 772.344.9436

PVC Glue 120°F -17°F

6" Pressure to 8" Non-Pressure

10. Follow all recommended procedures for joining PVC pipe and fittings as stated in ASTM SPEC. D 2855.

• Fast • App Temp: -17°F to 120°F • High Strength for PVC Pipe & Fittings • Schedule 40 & 80 up to 6” Dia. Pressure. 8” Dia. Non Pressure • For Potable Water, DWV, & Sewer Applications. • Meets ASTM D-2564

CENTAUR MANUFACTURING 635 NW Enterprise Dr. Port St Lucie, FL 34986 ph. 772-344-9436 • www.centaurpvc.com

STOCK CODE# CMT1Q NET CONTENTS QUART - 32 FL. OZ. (947 ml)

LowVOC

R

PW, DWV, SW

CLEAN PRIME

WARNING: EXTREMELY FLAMMABLE. HARMFUL OR FATAL IF SWALLOWED. ANTIDOTE: IN CASE OF INGESTION, DO NOT INDUCE VOMITING. CALL A PHYSICIAN IMMEDIATELY.

Max VOC per SCAQMD 1168/316A: 510G/L Low VOC products may be suitable or required for use on projects following green building codes or rating systems. READ THE FOLLOWING BEFORE USING: Contains Tetrahydrofuran, CAS# 109-99-9; Methyl Ethyl Ketone, CAS# 78-93-3; Cyclohexanone, CAS# 108-94-1 and Acetone, CAS# 67-64-1.

LIMITED WARRANTY: Manufacturer’s only obligation shall be to replace such quantities of the product proven to be defective. Return to manufacturer for free replacement. APPLICATION TEMP: -17°F TO 120°F (-28°C TO 48°C). STORAGE TEMP: 40°F TO 100°F (5°C TO 38°C).

Fast Set Time Ideal for any climate and all seasons. May be used for gas, conduit and other pressure & non pressure applications Application Temp: -17°F to 120°F · Storage Temp: 40°F to 100°F Viscosity: Min 500 cps @ 73°F · Max VOC per SCAQMD 1168/316A: 510G/L Up to 6" - Sched. 40 & 80 (Pressure) Up to 8" - Sched. 40 & 80 (Non Pressure) Performance Standards ASTM D-2564 Hydrostatic Burst Strength 2 Hours @73° 400 PSI Lap Shear Strength 2 Hours - 250 PSI 16 Hours - 500 PSI 72 Hours - 900 PSI Average 3 Year Shelf Life - Unopened Can

• Medium Set • Schedule 40 & 80 up to 8” Dia. Pressure, 10” Dia. Non Pressure • For Potable Water, DWV & Sewer Applications • Meets ASTM D-2564

WARNING: EXTREMELY FLAMMABLE. HARMFUL OR FATAL IF SWALLOWED. ANTIDOTE: IN CASE OF INGESTION, DO NOT INDUCE VOMITING. CALL A PHYSICIAN IMMEDIATELY.

Max VOC per SCAQMD 1168/316A: 510G/L Low VOC products may be suitable or required for use on projects following green building codes or rating systems. READ THE FOLLOWING BEFORE USING: Contains Tetrahydrofuran, CAS# 109-99-9; Methyl Ethyl Ketone, CAS# 78-93-3; Cyclohexanone, CAS# 108-94-1 and Acetone, CAS# 67-64-1.

CENTAUR MANUFACTURING 635 NW Enterprise Dr. Port St Lucie, FL 34986 ph. 772-344-9436 • www.centaurpvc.com

STOCK CODE# G32 NET CONTENTS QUART - 32 FL. OZ. (947 ml)

LowVOC

R

PW, DWV, SW

CLEAN

PVC CEMENT

CUT

MEDIUM BODY - GRAY

PRIME

WARNING: EXTREMELY FLAMMABLE DO NOT USE NEAR HEAT, SPARKS OR OPEN FLAME. STORE IN COOL, WELL VENTILATED AREA. May be absorbed through the skin. Harmful or fatal if swallowed. Use with adequate ventilation. Avoid prolonged breathing of vapors. Avoid contact with eyes or skin. Keep container tightly capped when not in use. KEEP OUT OF REACH OF CHILDREN - FIRST AID: EYES: Flush thoroughly with water for at least 15 minutes. Call physician immediately. INTERNAL: Do not induce vomiting. Call physician immediately. EXTERNAL: Wash thoroughly with soap and water and apply a skin lotion. Wash clothing before re-use.

DIRECTIONS STIR OR SHAKE BEFORE USING. 1. Cut pipe square with hand saw or pipe cutter and remove burrs from inside and outside diameters. 2. Clean pipe and fitting socket with Centaur Pipe Cleaner. Wipe off with a clean, dry cloth. 3. Check dry fit. Pipe should easily go 1/3 of the way into fitting. Use Centaur Primer. Primer will penetrate quickly for better bond. 4. Apply a thin coat of cement into socket and a full even coat to pipe. WARNING: Use appropriate size dauber or larger applicator if necessary. Do not puddle cement in socket fitting. 5. Engage pipe into fitting with slight twisting motion. Be sure pipe is bottomed into fitting. Hold pipe and fitting for 30 seconds. Wipe off excess cement. 6. Allow cement to cure before pressurizing pipe 7.As stated in ASTM D2855, when installing thin walled bell end pipe, do not apply an excess of cement in the bell socket.

CMT1Q

This cement is made with the highest quality materials and meets or exceeds ASTM SPEC. D 2564. All information provided is based on our laboratory testing, independent laboratory test results, and actual field experience. Properly used, this material will perform in accordance with applicable standards. Since we are unable to control conditions for which the product is being used, our only obligation will be the replacement of the cement.

CEMENT

PVC solvent cement contains methyl ethyl ketone, which breaks down the top layer of PVC on both the pipe and fitting to be cemented. It also contains PVC resin, which is essentially liquid PVC. Once the solvent breaks down the PVC pipe and fitting, the resin moves into the gaps between the PVC molecules. The solvent then evaporates and the two pieces of PVC are fused together permanently. Another important factor to take into consideration, is the size of the pipe. With larger pipe you need more resin to act as a filler. If the PVC solvent cement doesn't have the right amount of resin it can leave gaps when sealing and eventually fail. Centaur PVC Cement is the superior choice for top of the line electricians.

ASSEMBLE

A Formula That Sticks

100°F 32°F

APPLICATION TEMP: 32°F TO 110°F (0°C TO 43°C). STORAGE TEMP: 40°F TO 100°F (5°C TO 38°C).

LIMITED WARRANTY: Manufacturer’s only obligation shall be to replace such quantities of the product proven to be defective. Return to manufacturer for free replacement.

Scan for MSDS Sheet

Set Time Medium May be used for gas, conduit and other pressure & non pressure applications Application Temp: 32°F to 110°F · Store Temp: 40°F to 100°F Viscosity: Min 500 cps @ 73°F · Max VOC per SCAQMD 1168/316A: 510G/L Up to 8" - Sched 40 & 80 (Pressure) Up tp 10" - Sched Performance Standards ASTM D-2564 Hydrostatic Burst Strength 2 Hours @73° 400 PSI Lap Shear Strength 2 Hours - 250 PSI 16 Hours - 500 PSI 72 Hours - 900 PSI Average 3 Year Shelf Life - Unopened Can Scan for MSDS Sheet

Primers & Cleaners 100°F 32°F

10. Follow all recommended procedures for joining PVC pipe and fittings as stated in ASTM SPEC. D 2855.

• Fast Set • For PVC & CPVC Pipe and Fittings • All Sizes • All Schedules • Meets ASTM F-656

This cement is made with the highest quality materials and meets or exceeds ASTM SPEC. D 2564. All information provided is based on our laboratory testing, independent laboratory test results, and actual field experience. Properly used, this material will perform in accordance with applicable standards. Since we are unable to control conditions for which the product is being used, our only obligation will be the replacement of the cement.

PP32 CENTAUR PURPLE PRIMER

READ THE FOLLOWING BEFORE USING: Contains Tetrahydrofuran, CAS# 109-99-9; Methyl Ethyl Ketone, CAS# 78-93-3; Cyclohexanone, CAS# 108-94-1 and Acetone, CAS# 67-64-1.

CENTAUR MANUFACTURING 635 NW Enterprise Dr. Port St Lucie, FL 34986 ph. 772-344-9436 • www.centaurpvc.com

STOCK CODE# CMT1Q NET CONTENTS QUART - 32 FL. OZ. (947 ml) R

PW, DWV, SW

LowVOC

CUT

1. Prepare pipe according to the instructions shown on the images. 2. Apply a liberal coat of Purple Primer on both fitting socket and pipe end. 3. Apply solvent cement while primer is wet. Warning: Use appropriate size dauber or larger applicator if necessary. 4. For large diameter pipe, a second coat of primer may be necessary. HANDLE WITH CARE Please note that purple Primer/Cleaner will stain most materials and cannot be removed. LIMITED WARRANTY: Manufacturer’s only obligation shall be to replace such quantities of the product proven to be defective. Return to manufacturer for

CMT1Q

WARNING: EXTREMELY FLAMMABLE. HARMFUL OR FATAL IF SWALLOWED. ANTIDOTE: IN CASE OF INGESTION, DO NOT INDUCE VOMITING. CALL A PHYSICIAN IMMEDIATELY.

Max VOC per SCAQMD 1168/316A: 510G/L Low VOC products may be suitable or required for use on projects following green building codes or rating systems.

DIRECTIONS

CLEAN

PVC PRIMER

PRIME

WARNING: EXTREMELY FLAMMABLE DO NOT USE NEAR HEAT, SPARKS OR OPEN FLAME. STORE IN COOL, WELL VENTILATED AREA. May be absorbed through the skin. Harmful or fatal if swallowed. Use with adequate ventilation. Avoid prolonged breathing of vapors. Avoid contact with eyes or skin. Keep container tightly capped when not in use. KEEP OUT OF REACH OF CHILDREN - FIRST AID: EYES: Flush thoroughly with water for at least 15 minutes. Call physician immediately. INTERNAL: Do not induce vomiting. Call physician immediately. EXTERNAL: Wash thoroughly with soap and water and apply a skin lotion. Wash clothing before re-use.

CEMENT

Acetone Cleans the surface of the pipe to ensure a good seal.

»» »» »» »» »» »» »» »» »»

Quart · G32

free replacement. PRIMER FACILITATES AND STRENGHTENS JOINING. NOT TO BE USED ON ABS OR THIN-WALLED PVC PIPE AND FITTINGS. FOR USE IN POTABLE WATER, SEWER AND DWV. APPLICATION TEMP: 32°F TO 110°F (0°C TO 43°C) STORAGE TEMP: 40°F TO 100°F (5°C TO 38°C)

PP32 Centaur Purple Primer »» »» »» »» »» »» »» »»

Activation Time - Fast Acting Meets ASTM standard F-656 Use of primer is recommended for all schedules & sizes Application Temp: 32°F to 100°F · Storage Temp: 40°F to 100°F Max VOC per SCAQMD 1168/316A:550G/L CAUTION: Do not use on ABS or thin-walled PVC pipes & fittings All Schedules All Sizes Average 3 Year Shelf Life - Unopened Can

Scan for MSDS Sheet

STOCK CODE# CMT05P NET CONTENTS ½ PINT - 8 FL. OZ. (237 ml)

Quart · CMT1Q Gallon · CMT1G

100°F 32°F

CMT Series

Centaur PVC East ph:772.344.9436 · www.centaurpvc.com

This cement is made with the highest quality materials and meets or exceeds ASTM SPEC. D 2564. All information provided is based on our laboratory testing, independent laboratory test results, and actual field experience. Properly used, this material will perform in accordance with applicable standards. Since we are unable to control conditions for which the product is being used, our only obligation will be the replacement of the cement.

• Effectively Removes Oils, Dirt, Grease & Other Foreign Matter • For PVC, CPVC and ABS Pipe & Fittings

READ THE FOLLOWING BEFORE USING: Contains Tetrahydrofuran, CAS# 109-99-9; Methyl Ethyl Ketone, CAS# 78-93-3; Cyclohexanone, CAS# 108-94-1 and Acetone, CAS# 67-64-1.

CENTAUR MANUFACTURING 635 NW Enterprise Dr. Port St Lucie, FL 34986 ph. 772-344-9436 • www.centaurpvc.com

STOCK CODE# CMT1Q NET CONTENTS QUART - 32 FL. OZ. (947 ml) R

PW, DWV, SW

LowVOC

1. Apply pipe cleaner with dauber or suitable applicator to inside of fitting and outside pipe diameter. WARNING: Use appropriate size dauber or larger applicator if necessary. 2. Wipe off with clean, dry cloth. 3. Apply Centaur’s Primer and Cement as instructed on the label.

quantities of the product proven to be defective. Return to manufacturer for

PRIMER FACILITATES AND STREGTHENS JOINING. NOT TO BE USED ON ABS OR THIN-WALLED PVC PIPE AND FITTINGS. FOR USE IN POTABLE WATER, SEWER AND DWV. APPLICATION TEMP: 32°F TO 110°F (0°C TO 43°C). STORAGE TEMP: 40°F TO 100°F (5°C TO 38°C).

LIMITED WARRANTY: Manufacturer’s only obligation shall be to replace such

CMT1Q

WARNING: EXTREMELY FLAMMABLE. HARMFUL OR FATAL IF SWALLOWED. ANTIDOTE: IN CASE OF INGESTION, DO NOT INDUCE VOMITING. CALL A PHYSICIAN IMMEDIATELY.

DIRECTIONS

CLEAN

PVC CLEANER

Max VOC per SCAQMD 1168/316A: 510G/L Low VOC products may be suitable or required for use on projects following green building codes or rating systems.

CUT

C32 CENTAUR PIPE CLEANER

PRIME

WARNING: EXTREMELY FLAMMABLE DO NOT USE NEAR HEAT, SPARKS OR OPEN FLAME. STORE IN COOL, WELL VENTILATED AREA. May be absorbed through the skin. Harmful or fatal if swallowed. Use with adequate ventilation. Avoid prolonged breathing of vapors. Avoid contact with eyes or skin. Keep container tightly capped when not in use. KEEP OUT OF REACH OF CHILDREN - FIRST AID: EYES: Flush thoroughly with water for at least 15 minutes. Call physician immediately. INTERNAL: Do not induce vomiting. Call physician immediately. EXTERNAL: Wash thoroughly with soap and water and apply a skin lotion. Wash clothing before re-use.

CEMENT

»»Our most popular selling PVC cement. »»Fast Set Time »»Up to 4" - Sched. 40 (Pressure) Up to 6" - Sched. 40 (Non Pressure) »»May be used for gas, conduit and other pressure & non pressure applications »»Application Temp: 32°F to 110°F · Store Temp: 40° to 100°F »»Viscosity: Min 90 cps @ 73°F · Max VOC per SCQMD 1168/316A: 510G/L »»Not for scheldule 80 »»Performance Standards ASTM D-2564 »»Hydrostatic Burst Strength 2 Hour @ 73­° 400 PSI »»Lap Shear Strength 2 Hours - 250 PSI 16 Hours - 500 PSI 72 Hours - 900 PSI »»Average 3 Year Shelf Life - Unopened Can

10. Follow all recommended procedures for joining PVC pipe and fittings as stated in ASTM SPEC. D 2855.

ASSEMBLE

CMT05P

110°F 32°F

Scan for MSDS Sheet

G32 Centaur Medium Bodied Gray Glue

Scan for MSDS Sheet

Quart · PP32

4" Pressure to 6" Non-Pressure

½ Pint · CMT05P Pint · CMT1P

6" Pressure to 14" Non-Pressure

1. Cut the pipe square and remove all burrs. 2. Check fitting of pipe. If too loose or too tight, pipe should not be used. Ideal fit between pipe & fitting before cementing allows pipe to enter to full depth of socket easily. 3. Remove all dust, moisture, grease, oil and any other foreign material from pipe and fitting. Clean pipe an fitting with CENTAUR CLEANER and CENTAUR PURPLE PRIMER. While surface is still damp with primer apply cement as follows. 4. Apply enough cement uniformly to pipe & fitting to form a bead of cement at outside end of pipe. Prevent excess cement from forming on bare inside walls of pipe. 5. Brush cement generously on the outside of pipe to depth of fitting. Do not thin cement with primers or cleaners. 6. Immediately after cement is applied, insert pipe to bottom of socket, using a quarter twisting motion, and hold in place 30 seconds until cement sets. Assemble parts QUICKLY. If cement is not fluid, recoat both parts and repeat procedure. 7. Remove excessive cement with a dry cloth only. 8. Allow about 30 minutes for good handling strength. Cure time before testing depends on size, fit, temperature and pressures. Refer to ASTM SPEC. D 2855, for recommended set and cure time. 9. Keep container closed at all times when not using to avoid moisture absorption and vapor losses. Keep cement from freezing. 10. Follow all recommended procedures for joining PVC pipe and fittings as stated in ASTM SPEC. D 2855.

ASSEMBLE

CHEMICAL BREAKDOWN

Cyclohexanone Used as a filler to close gaps.

»» »» »» »» »» »» »» »» »» »»

DIRECTIONS

Methyl Ethyl Ketone Works together with Tetrahydrofuran to break down the PVC molecules and protect the seal.

Tetrahydrofuran Helps breakdown the PVC molecules.

Scan for MSDS Sheet

Quart · AT32

Centaur PVC Centaur PVC offers a wide range of PVC solvents for all your material joining needs. We have teamed up with one of the countries leading PVC solvent manufacturers to bring you another quality product line. All of our PVC Solvents, Primers, and Cleaners meet or exceed industry standards and are produced under some of the strictest quality control measures in the market. From random sample testing to cap torque verification, we pride ourselves on manufacturing only the highest quality products. The CMT series of solvent cement will allow for the joining of pipe up to 6” (non-pressure), while the competitors only go up to 4” (non-pressure). Centaur cement is also environmentally friendly and only uses products that are Low VOC (Volatile Organic Compound), which makes us the primary choice for any DIY green projects and LEED projects. A newly added addition to our line is the AT32 an “all temperature” cement that allows for application in climates from -17°F to 120°F while still being able to join 6” (non-pressure) pipe.

DIRECTIONS

1. Stir or shake before using. 2. Cut pipe square with hand saw or pipe cutter and remove burrs from inside and outside diameters. 3. Clean pipe and fitting socket with Centaur’s Pipe Cleaner. Wipe off with a clean dry cloth. 4. Check dry fit. Pipe should easily go 1/3 of the way into fitting. Use Centaur’s Primer. Primer will penetrate quickly for better bond. 5. Apply a thin coat of cement into socket and a full even coat to pipe. WARNING: Use appropriate size dauber or larger applicator if necessary. Do not puddle cement in socket fitting. 6. Engage pipe into filling with slight twisting motion. Be surepipe is bottomed into fitting. Hold pipe ad fitting for 30 seconds. Wipe off excess cement. 7. Allow cement to cure before pressurizing pipe. 8. As Stated in ASTM D2855, when installing thin walled bell end pipe, do not apply an excess of cement in the bell socket.

CEMENT

PVC CEMENT

CUT

AT32 CENTAUR ALL TEMP. CEMENT

ASSEMBLE

WARNING: EXTREMELY FLAMMABLE DO NOT USE NEAR HEAT, SPARKS OR OPEN FLAME. STORE IN COOL, WELL VENTILATED AREA. May be absorbed through the skin. Harmful or fatal if swallowed. Use with adequate ventilation. Avoid prolonged breathing of vapors. Avoid contact with eyes or skin. Keep container tightly capped when not in use. KEEP OUT OF REACH OF CHILDREN - FIRST AID: EYES: Flush thoroughly with water for at least 15 minutes. Call physician immediately. INTERNAL: Do not induce vomiting. Call physician immediately. EXTERNAL: Wash thoroughly with soap and water and apply a skin lotion. Wash clothing before re-use.

CMT1Q

This cement is made with the highest quality materials and meets or exceeds ASTM SPEC. D 2564. All information provided is based on our laboratory testing, independent laboratory test results, and actual field experience. Properly used, this material will perform in accordance with applicable standards. Since we are unable to control conditions for which the product is being used, our only obligation will be the replacement of the cement.

AT32 Centaur All Temperature Cement

free replacement.

C32 Centaur Pipe Cleaner »» »» »» »» »» »» »»

Activation Time - Fast Acting Effectively removes oils, dirt, grease and other foreign matter For all types of PVC , CPVC, ABS pipes & fittings all schedules & sizes Cleaning of pipes is highly recommended prior to cementing Application temp: 32°F to 110°F · Storage Temp: 40°F to 100°F Max VOC per SCAQMD 1168/316A: 550G/L Average 3 Year Shelf Life - Unopened Can

Scan for MSDS Sheet

Quart · C32 Scan for MSDS Sheet

Centaur PVC East ph: 772.344.9436 · www.centaurpvc.com

Scan for MSDS Sheet