Relay 208

15 downloads 379 Views 10MB Size Report
Control both RELAY 208 and computer from up to 3 rooms (or many more if you use the ... Control your computer, RELAY 208
LINTRONIC RELAY 208

http://www.lintronic.dk

RELAY 208

http://www.lintronic.dk

Updated: 101125

LINTRONIC RELAY 208

Date

Revised

yymmdd

Text

101125

Improved drawings showing control of 15 relays

100520

Remote controlled fireplace added

091208

Curtains drawings added

091110

COMBO configuration introduced in firmware version 001.034.036.

091008

RELAY 208 as CommandConverter: http://www.lintronic.dk/CommandConverter.pdf

090923

Various drawings added/improved.

090920

Mode 5 (digital input controlled)

090618

Wholes corrected to holes. Thanks, Kaavya :o)

090610

Mode 5 added. Special firmware. Not customer programmable.

090403

This doc released

http://www.lintronic.dk

LINTRONIC RELAY 208

RELAY 208

RELAY 208 INCLUDES: - 1 pcs polycarbonat cabinet - 10 pcs wire-plugs (PG7) - 8 pcs 3-way screw-terminals (relays) - 1 pcs 5-way screw-terminal (dig input, RS485) - 1 pcs 2-way screw-termainal (power) ACCESSORIES Depending on your installation, you may need in addition: - a power supply (12 volt, minimum 300 mA) - a communication cable for configuration - IR receiver(s) MODE At delivery RELAY 208 is configured for mode: BEOLIVING-2 This is easily changed in the free of charge Configuration program available on our web-site. PICTURES When the installation is running, LinTronic would appreciate a picture and a few lines explaining how you use the RELAY 208. Also we would be happy if we could use your picture and story in our next NewsLetter inspiring other customers.

http://www.lintronic.dk

LINTRONIC RELAY 208

Customer configurable G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

Each of the two IR receivers inputs may optionally: ! !

Control the relays. Example: Control lights/curtains/blinders from two rooms. send a command holding the decoded IR signal to the any of the two commports Example: Control a computer, a TT455-RT-238, etc.

Each of the two commports may optionally: ! !

Control the relays. Example: From a computer, a TT455-RT-238, etc. Copy LinTronic protocols commands to the other commport Example: Control relays and a TT455-RT-238 on each commport, or let a computer control the relays and a TT455-RT-238 on the other commport.

These combinations offers a wide range of possibilites: ! ! ! !

Two TT455-RT-238's may work together through a RELAY 208 offering remote control of RELAY 208 or ecah of the TT455-RT-238's from up to 4 rooms (or many more if you use the commports RS485 interface). Control both RELAY 208 and computer from up to 3 rooms (or many more if you use the commports RS485 interface). The RELAY 208 may also work as a "communication converter" translating one set of commands into another set of commands working on the same or a different baudrate, even a different protocol. Get the most of of your RELAY 208. LinTronic offer customized software.

http://www.lintronic.dk

LINTRONIC RELAY 208

OEM ready COM2 COM1

GND 12V

Other systems: Light, projectors, screens, etc.

COMPUTER / CONTROLLER

G B A 2 1

C A R 5

C A R 6

C A R 7

C A R 8

123

1

2

3

4

C A R

C A R

C A R

C A R

455 KHz receiver (AMX, B&O, etc.) 32 - 56 KHz receiver

RELAY 208 is designed to meet our customers needs. Simply tell us what you need and we make it happen:

! ! ! !

Want to use a special remote control ? Send detected codes to your computer ? Control from a computer ? Activated from a wall switch ? Also see this document: http://www.lintronic.dk/CommandConverter.pdf

http://www.lintronic.dk

LINTRONIC RELAY 208

RELAY 208 Digital inputs RS485 Power

7

C A R 8

3

4

C A R

C A R

C A R

C A R

COM2

6

5

C A R 2

COM1

C A R

C A R

1

IR receiver 1 IR receiver 2

! ! ! ! ! ! !

G B A 2 1

123

GND 12V

8 switching relays - 12 vac/vdc - 24 vac/vdc - 48 vac/vdc - 115 Vac - 230 vac

Commport 2 TT455-RT-238 Computer, etc. Commport 1 Computer, TT455-RT-238, etc.

Reserved

2 commports. Optionally connect one computer and one TT455-RT-238 or two TT455-RT-238's, or two computers, etc. etc. COMMPORT2 optional RS232 or RS485 2 individual IR receivers. Control your computer, RELAY 208 and/or TT455-RT-238 from up to 4 rooms. BeoSystem Theater Detector. Controls your lights, curtains, projector, etc. 2 digtal inputs. Switch activated open/close all, etc. Heavy-duty high-voltage switching relays. Now you may control high voltage lamps or blinds etc. directly from the RELAY board. LED's indicators on each relay and digital inputs.

http://www.lintronic.dk

LINTRONIC RELAY 208

Points of interest

1 2 3

Default jumper position 2-3. 1-2 = RS485, 2-3=RS232 G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

Connectors can be mounted horizontically or vertically

http://www.lintronic.dk

COM1

123

LINTRONIC RELAY 208

Power supply 220 vac 50 Hz

EURO plug If you use our PowerAdap-002 then cut off the connector and feed the black wire to 12 volt ground and the black-white wire to 12 volt +.

1.5V

12V

Set power-adaptor for 12 volt

G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

http://www.lintronic.dk

COM1

123

LINTRONIC RELAY 208

Switches and LED's G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

1: COMMUNICATION RESET (only possible during power-up) In order to set default communication for both commports (address = 1 and baudrate = 19200,n,8,1): - press and hold this switch - apply power - wait for both LED indicators to turn on Heartbeat indicator - release switch - blinks every second to confirm firmware is running

Programming indicator 2: PROGRAMMING In some modes this switch can be used to adjust timing, etc. OBSERVE: If you hold this switch activated during power-up, then LED 2 will turn on, indicating that you are about to enter our factory test-program. The test procedure is carried out by our production and is not public available. Simply release the switch and continue normal operation. If you want to test RELAY 208, then please do it in the Configurator.

http://www.lintronic.dk

LINTRONIC RELAY 208

Switches and LED's G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

Mode: 1-32, Curtains Up/Down Heartbeat indicator - blinks every second to confirm firmware is running

Test ALL UP

Test ALL DOWN

http://www.lintronic.dk

LINTRONIC RELAY 208

Switches and LED's G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R

C A R

7

8 1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

Mode: 1-64, Individual On/Off Heartbeat indicator - blinks every second to confirm firmware is running

Test ALL ON/OFF

Test ALL OFF

http://www.lintronic.dk

LINTRONIC RELAY 208

Relays G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

All 8-relays are working in the same way. This is one example covering all.

"Relay activated" indicator

C A R Common

Resting connection to Common when relays is resting (also called Normally Closed)

Activated connection to Common when relays is activated (also called Normally Open)

http://www.lintronic.dk

LINTRONIC RELAY 208

Digital inputs Mode: 1-32, Up/Down Input 1, can be controlled a normal switch or a dusk/dark sensor: Off, closes all curtains. On, Opens all curtains. Input 2, can be controlled a normal switch: On > 100 ms and less than 650 ms, opens all curtains. On > 1000 ms closes all curtains.

Mode: BeoLiving See following pages.

G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

http://www.lintronic.dk

COM1

123

LINTRONIC RELAY 208

RS232 connectors 1-2: RS485 2-3: RS232

GND 12V

G B A 2 1

C A R

C A R

C A R

C A R

COM2

123 5

6

7

8 1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

1: DTE (TERMINAL PINOUT ) Pin 1 - Unused Pin 2 - Transmit data (Out) Pin 3 - Receive data (In) Pin 4 - Data Terminal Ready (-9 volt out) Pin 5 - Ground Pin 6 - Unused Pin 7 - 5 volt out Pin 8 - Unused Pin 9 - Ring indicator (In)

http://www.lintronic.dk

2: DCE (COMPUTER PINOUT) Pin 1 - Unused Pin 2 - Receive data (In) Pin 3 - Transmit data (Out) Pin 4 - Data Terminal Ready (-9 volt out) Pin 5 - Ground Pin 6 - Unused Pin 7 - 5 volt out Pin 8 - Unused Pin 9 - Ring indicator (In)

LINTRONIC RELAY 208 1-2: RS485 2-3: RS232

RS485

123

Pin 7, A

1

Pin 8, B

RELAY 208 may control and may be controlled from up to 32 TT455-RT-238's

1-2: RS485 2-3: RS232 123

1-2: RS485 2-3: RS232 123

Pin 7, A

32

Pin 8, B

Any twisted 2-wire cable can be used. For example CAT5. Cable length up 1000+ meters.

When using RS485 do not use RS232 commport 2.

G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

http://www.lintronic.dk

COM1

123

NO! To computer, etc.

LINTRONIC RELAY 208

InfraRed receiver inputs G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

CAB

TT-IR-8087030

COM1

123

X

This connector is reserved ! Do not insert or damage may occur. TT-IR-8087030

A 5 volt B IR signal C Ground

Jack connector seen from solderside

A C B http://www.lintronic.dk

A

B C

LINTRONIC RELAY 208

Multiroom remote control G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

TT-IR-8087030

TV

ADIO T R

TV

LIGH

E VTAP

RE

VTAP E

E ATAP CORD

CD ATAP E

7

9

8 9

4

6

5

5 4

6

1

3

2

2 1

U

TEXT

MEN

0

3 0

TEXT

MEN

>

>

U

>>

>>

>>

GO

EXIT

>

LIST

LIST

>

STO P

P STO

FSEN

OLU G &

BAN

BANG

& OLU FSE

N

>

>

>

>

GO

EXIT

RADI

O

DVD RECO RD

8 7

http://www.lintronic.dk

LIGHT

SAT

CD DVD

SAT

>>

LINTRONIC RELAY 208

Multiroom remote control G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

TT-IR-8087030

TV

ADIO T R

TV

LIGH

E VTAP

RE

VTAP E

E ATAP CORD

CD ATAP E

7

9

8 9

4

6

5

5 4

6

1

3

2

2 1

U

TEXT

MEN

0

3 0

TEXT

MEN

>

>

U

>>

>>

>>

GO

EXIT

>

LIST

LIST

>

STO P

P STO

FSEN

OLU G &

BAN

BANG

& OLU FSE

N

>

>

>

>

GO

EXIT

RADI

O

DVD RECO RD

8 7

http://www.lintronic.dk

LIGHT

SAT

CD DVD

SAT

>>

LINTRONIC RELAY 208

2-way see-through RS232 G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

Computer controls both the RELAY 208 and the TT455-RT-238.

CD

DIO

RA

E

9

0

>>

HT

P TA DA OR

2 6

ME

3

NU

>>

LIG D

DV

EC ER

AP VT

5

XT

IT

EX

BANG & N UFSE OL

http://www.lintronic.dk

T SA

8

TE

1

>

TV

7 4

GO

T

OP ST

LIS

> >

>

TT455-RT-238 controls both the RELAY 208 and the computer

LINTRONIC RELAY 208

2-way see-through RS232 G B A 2 1

C A R

C A R

6

5

COM2

GND 12V

C A R 7

C A R 8

COM1

123

1

2

3

4

C A R

C A R

C A R

C A R

TT455-RT-238 controls both the RELAY 208 and the other TT455-RT-238

HT

DIO RA CD

LIG

D DV

TV T SA

AP VT

E

RD CO

AP AT

E

9

RE

6

8

3

5

7

U

EN

2

4

M 0

T EX

>>

>

1 T

>

GO

>>

IT

>

>>

CD

DIO

RA

9

0 6

ME

3

>>

NU

IT

EX

BANG & N UFSE OL

http://www.lintronic.dk

E

2

>

HT

P TA DA OR

5

XT

>

D

8

TE

1

>

EN

LU

DV

EC ER

7 4

> GO

O

T

OP ST &

LIS

FS

NG BA

LIG

AP VT

P

O ST

T SA

T

TV

>

EX

LIS

TT455-RT-238 controls both the RELAY 208 and the other TT455-RT-238

LINTRONIC RELAY 208

I want it all … RS485 G B A 2 1

C A R

C A R

6

5

COM2

GND 12V

digital inputs C A R 7

C A R 8

COM1

123

1

2

3

4

C A R

C A R

C A R

C A R

TV

LIG H

T

SA T

DV D

VT AP E

ORD

7

9 5 6 2

XT

3 0 ME

>

NU

>> >

GO

>

LIS T EX

IT

>

ST OP

BANG

http://www.lintronic.dk

&

OLUF SEN

>>

IO

ATA PE

8 4 1 TE

RA D CD

REC

LINTRONIC RELAY 208

… and then some ! RS485 G B A 2 1

COM2

GND 12V

digital inputs C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

TV

LIG HT

SA T VT AP E

DV D ORD

7

ATA PE

8 4

9 5

1

6 2

TE XT

3 0

>

ME NU

>> >

GO

LIS

>

T EX IT

>

ST OP

BANG

http://www.lintronic.dk

&

OLUF SEN

>>

RA DIO CD

REC

LINTRONIC RELAY 208

Controlling 16 relays - or more Board 1

Board 2

Relay numbers: 1-8

Relay numbers: 9-16 7

C A R

GND 12V

8

COM1

C A R

No IR receivers are rquired for computer control

4

C A R

C A R

C A R

C A R

One or two receivers can be used on each board

ComCab-001 (straight-through)

At least one is required for remote control

ComCab-001 (straight-through)

IO

HT

D RA

LIG

CD

TV

D DV

T SA

OR

EC ER

PE TA DA

AP VT

9 8 6

7 5

3

4 2

NU

ME

1

0 T EX

T

>

8

C A R

3

>> GO

>

7

C A R

C A R

2

IT EX

>

6

5

C A R

C A R

1

COM1

C A R

C A R 4

123

>>

G B A 2 1

3

COM2

6

5

C A R

COM2

C A R

C A R

2

G B A 2 1

1

GND 12V

123

>

T LIS

BA

NG

&

O

LU

FS

EN

OP ST

BANG

&

N UFSE OL

You can control all relays and the computer by the remote, as well as control all relays from the computer.

http://www.lintronic.dk

LINTRONIC RELAY 208

Controlling 16 relays - or more 8 Curtains - up/down MODE 1-32 is recommended for up/down control of curtains. Adress 1

Address 2

First curtain number: 1

First curtain number: 5

6

5

C A R 7

C A R 8

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8

2

3

4

C A R

C A R

C A R

C A R

Curtain 1

Relay 1 Relay 2 Relay 3 Relay 4 Relay 5 Relay 6 Relay 7 Relay 8

Curtain 2

Curtain 1 UP Curtain 1 DOWN Curtain 2 UP Curtain 2 DOWN Curtain 3 UP Curtain 3 DOWN Curtain 4 UP Curtain 4 DOWN

COM1

1

123

1

2

3

4

C A R

C A R

C A R

C A R

Curtain 5

Relay 1 Relay 2 Relay 3 Relay 4 Relay 5 Relay 6 Relay 7 Relay 8

Curtain 6

Curtain 5 UP Curtain 5 DOWN Curtain 6 UP Curtain 6 DOWN Curtain 7 UP Curtain 7 DOWN Curtain 8 UP Curtain 8 DOWN

About Configuration, se next page. http://www.lintronic.dk

COM1

G B A 2 1

123

COM2

C A R

COM2

Curtain 7 C A R

Curtain 8

G B A 2 1

Curtain 3

GND 12V

Curtain 4

LINTRONIC RELAY 208

Controlling 16 relays - or more 8 Curtains - up/down MODE 1-32 is recommended for up/down control of curtains. This shows how you configure Address 1

This shows how you configure Address 2

http://www.lintronic.dk

LINTRONIC RELAY 208

Controlling 16 relays - or more 16 relays - on/off MODE 1-64 is recommended for individual on/off control Address 2

First relay number: 1

First relay number: 9

7

C A R 8

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8

4

C A R

C A R

C A R

C A R

COM1

3

123

1

2

3

4

C A R

C A R

C A R

C A R

About Configuration, se next page.

http://www.lintronic.dk

COM1

G B A 2 1

2

COM2

6

5

C A R

COM2

C A R

C A R

1

G B A 2 1

123

GND 12V

Adress 1

LINTRONIC RELAY 208

Controlling 16 relays - or more 16 relays - on/off MODE 1-64 is recommended for individual on/off control This shows how you configure Address 1

This shows how you configure Address 2

http://www.lintronic.dk

LINTRONIC RELAY 208

Curtains control LinTronic Relay 208 has been carefully designed to control curtains, blinders, screens, lifts, motors, etc.

IMPORTANT If you are controlling ac-motors, make sure you always select "mode 01-32". Mode 01-32 has automatic protection against UP and DOWN beeing active at the same time, which will destroy the motor. If you are controlling dc-motors, optionally select mode 01-32 or 01-64. http://www.lintronic.dk

LINTRONIC RELAY 208

Switch / relay controlled curtains

654321

Typically powered by 12 volt

12 volt 0 volt

RELAY 208

UP

DOWN

C A R C A R 220 vac

12 volt power supply http://www.lintronic.dk

LINTRONIC RELAY 208

Switch / relay controlled curtains Powered by 220 volt

4321

Connector for 220 volt

Connector for IR receiver IR receiver can be removed or left working in parallel with the Relay 208, using the original remote control.

RELAY 208

UP

DOWN

C A R C A R

http://www.lintronic.dk

1 = 15 volt output, do not use 2 = Ground 3 = Open 4 = Close

LINTRONIC RELAY 208

Relays (controlling motors) Suggested mode: 1-32, Up/Down

Up Down Up Down

CURTAIN 4

CURTAIN 3

G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

Up CURTAIN 2 Down Up Down

http://www.lintronic.dk

CURTAIN 1

LINTRONIC RELAY 208

Relays (controlling motors) Suggested mode: 1-32, Up/Down

Motors powered by 12 - 48 volt dc G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

12 - 48 volt dc

Up Down

http://www.lintronic.dk

MOTOR

LINTRONIC RELAY 208

SOMFY REMOTE CONTROLLED CURTAINS If curtains are already installed … see next page. If curtains are not already installed, then save the RF receiver and the remote control and control curtains motors directly as normal 12 or 24 volts motors.

C A R

C A R Plus Minus

MOTOR

POWER 12 or 24 volt

http://www.lintronic.dk

230 vac

LINTRONIC RELAY 208

SOMFY REMOTE CONTROLLED CURTAINS If you want both SOMFY control as well as B&O control and/or computer control, use the below wiring.

C A R

C A R Plus Minus

MOTOR

RF RECEIVER

POWER 12 or 24 volt

http://www.lintronic.dk

230 vac

LINTRONIC RELAY 208

RF CONTROLLED CURTAINS Open the RF remote and connect/solder the relays directly to the buttons. This solution will work on any kind of RF remote control

G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8

123

TV

LIGHT RADIO

SAT

DVD

CD

VTAPE RECORD ATAPE

0

MENU

>

TEXT

GO

LIST STOP

>>

>

4

6

>

3

9

3

>

2

8 5 2

>>

1

COM1

7 4 1

C A R

C A R

C A R

C A R BANG & OLUFSEN

http://www.lintronic.dk

EXIT

LINTRONIC RELAY 208

RF CONTROLLED FIREPLACE Open the RF remote and connect/solder the relays directly to the buttons. This solution will work on any kind of RF remote control

G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

UP

OFF

http://www.lintronic.dk

DOWN

LINTRONIC RELAY 208

Relays (controlling motors) Suggested mode: 1-32, Up/Down

Controlling 115 - 230 vac G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

115 - 230 vac (fused)

Up Down

http://www.lintronic.dk

MOTOR

LINTRONIC RELAY 208

Relays (controlling all type of lamps) Suggested mode: 1-64, On/Off

Controlling 115 - 230 vac G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

115 - 230 vac (fused)

http://www.lintronic.dk

LINTRONIC RELAY 208

Configuration Connect a computer to commport 1 using a normal RS232 communication cable (9-pin straight through) or a USB-RS232 converter (for example ComCab-003). Apply 12 vdc power.

12 volt dc

G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

http://www.lintronic.dk

COM1

123

LINTRONIC RELAY 208

Configuration Download and install our free of charge Configurator program from our web-site: http://www.lintronic.dk - Support - Download

http://www.lintronic.dk

LINTRONIC RELAY 208

Configuration FUNCTION / MODE MODE 01-32 Is specifically designed to control up/down control of curtains/motors. 8 boards (or more upon request) can communicate in RS232 cascade. Each RELAY 208 controls up to 4 motors and relays are paired 2 by 2: Motor 1 = RELAY 1 and 2 Motor 2 = RELAY 3 and 4 Motor 3 = RELAY 5 and 6 Motor 4 = RELAY 7 and 8 The firmware does not allow a motors Up and DOWN relays to be active at the same time (ac motor protection). If you command UP, then DOWN will be turned off first. If you command DOWN, then UP will be turned off first. When UP/DOWN is commanded. NOTE: However, if you decide to use only RELAY 1-2 and RELAY 3-4 for control of two motors, you may optionally control RELAY 5-8 directly for lights etc.

MODE 01-64 Is designed for manual on/off control of individual relays. 8 boards (or more upon request) can communicate in RS232 cascade. There is no dependency between the relays (1).

Customized firmware The many combinations of mode 01-32 and 01-64, and triggering by Numbers, Colors, Beo5, Input1 On/Off and Input2 On/Off, makes the RELAY 208 the most flexible solution on the market. Furthermore we offer customized control by two optional Triggers A and B. Trigger A/B can be for example RS232 commands from a computer/controller, a special pulse/pause reading of the digital inputs, and infrared command or … The existing triggers as well as Trigger A/B can control the relays, the digital outputs or an RS232 command for a projector, a light system, etc. on any of the two comports, etc. Let us know how we can help you. (1) Relays can all be ON at the same time, so care and consideration is required when controlling ac motors (which may be destroyed if power/phase is applied on both control wires at the same time.

http://www.lintronic.dk

LINTRONIC RELAY 208

Configuration Function/Mode: 01-32 up/down

1 up 1 down 2 up 2 down 3 up 3 down 4 up 4 down

In mode 01-32 the relays are paired 2 by 2 as illustrated. Example: 1 up = relay 1 timing, 1 down = relay 2 timing. You can set different timing for up/down.

http://www.lintronic.dk

LINTRONIC RELAY 208

Configuration REMOTE MODE You can operate the RELAY 208 in either Light Normal or Light Link mode (refers to the BEO4 and BEO5).

FIRST RELAY In each relay box, you can specify the number of the first relay, ranging from 1 to 57. This allows you to individually control each of the relays or make group control. Group Control Let us assume that in relay box 1, we set the first relay to be number 1 and in relay box 2, we set the first relay to be number 5. This means that: - in relay box 1 we have relays 1, 2, 3, 4, 5, 6, 7 and 8. - in relay box 2 we have relays 5, 6, 7, 8, 9, 10, 11 and 12. When you control relay 1 through 4 and relay 9 through 12, you will only activate one relay, but if you activate relay 5 through 8 you will actually activate one relay in each of the two relay boxes. This is a very simple way of controlling multiple relays with only one command.

ALL RELAYS Allows you to specify 0 or 9 to be the command controlling all relays.

http://www.lintronic.dk

LINTRONIC RELAY 208

Configuration SETTINGS IR1 -> RELAYS, IR2 -> RELAYS Determines individually whether the IR input 1 and 2, may control the relays. IR1 -> COMMPORT1, IR1 -> COMMPORT2, IR2 -> COMMPORT1, IR2 -> COMMPORT1, Determines individually whether the IR input 1 and 2, should send a command on the respective commports. Can be used to optionally control a computer or for example a TT455-RT-238 on the two commports. COMMPORT1 -> COMMPORT2, COMMPORT1 -> COMMPORT2, Determines individually whether the commport 1 and 2 should copy incoming LinTronic telegrams to the other commport. TT455-RT-238 ON COMMPORT1, TT455-RT-238 ON COMMPORT2, Instructs the RELAY 208 to listen to and optionally be controlled by incoming telegrams/command from a connected TT455-RT-238 sending its detected IR code through the RELAY 208 to a computer or another TT455-RT-238 connected to the other commport. COMMPORT2 = RS485 Check this box if you use commports 2's industrial 2-wire long-range RS485 bus instead of the RS232.

http://www.lintronic.dk

LINTRONIC RELAY 208

Configuration RELAYS CONTROL AND TIMING For each relay you can select: Active - Specifies whether this relay can be operated. Numbers - Specifies whether this relay can be remote controlled by "LIGHT UP" or "LIGHT DOWN". Colors - Specifies whether this relay can be remote controlled by short or long activations of the colors RED, GREEN, YELLOW and BLUE. BEO5, Control, Function - Specifies whether this relay can be remote controlled by the BEO5's Control and Function commands, which allows control of a specific relay for a specific time. RemoteDelay1 - Specifies whether remote control of this relay, should first allow the delay (Delay 1) and then activate the relay (Active 1).

Delay 1 - Timing for Delay 1.

Delay 2 - Timing for Delay 2.

Active 1 - Timing for Delay 1.

Active 2 - Timing for Delay 2.

Input 1 Off - Specifies whether this relay should be activated Up/On for the specified Delay1/Active1 timing, when the digital input 1 is released.

Input 2 Off - Specifies whether this relay should be activated Up/On for the specified Delay2/Active2 timing, when the digital input 2 is released.

Input 1 On - Specifies whether this relay should be activated Down/On for the specified Delay1/Active1 timing, when the digital input 1 is activated.

Input 2 On - Specifies whether this relay should be activated Down/On for the specified Delay2/Active2 timing, when the digital input 2 is activated.

InputDelay1 - Specifies whether the activation of the relay should first allow the delay (Delay 1) and then activate the relay (Active 1).

InputDelay2 - Specifies whether the activation of the relay should first allow the delay (Delay 2) and then activate the relay (Active 2).

ON1-OFF2 - Specifies whether the relay should use Delay1/Active1 timing when input 1 is activated, and Delay2/Active2 timing when input 1 is released.

ON2-OFF1 - Specifies whether the relay should use Delay2/Active2 timing when input 2 is activated, and Delay1/Active1 timing when input 2 is released.

TriggerA - Special trigger agreed with customers in specialized firmware: RS232 commands, digital input timing, etc.

TriggerB - Special trigger agreed with customers in specialized firmware: RS232 commands, digital input timing, etc.

http://www.lintronic.dk

LINTRONIC RELAY 208

Configuration TIMING Each timing (Delay1, Active1, Delay2, Active2) consist of 4 values: Hours, Minutes, Seconds and Units. Hours range from 0 to 24, Minutes range from 0 to 59, Seconds range from 0 to 59 and Units range from 0 to 249. One unit is 4 ms, meaning that 0.5 second = 125 units. The timing is entered with "," as seperator. Example: 2 hours, 3 minutes, 8 seconds and 0 units are entered as: 2,3,8,0

http://www.lintronic.dk

LINTRONIC RELAY 208

Configuration A customer wanted to control a motorized floor and a lift. When Trigger A is detected, open the floor, raise the TV and close the floor. When Trigger B is detected, open the floor, lower the TV and close the floor. The timing was like this: When Trigger A is detected: - Wait 0 seconds, then activate relay 8 for 31 seconds (opens the floor). - Wait 32 seconds, then activate relay 1 for 17 seconds (raises the TV). - Wait 50 seconds, then activate relay 7 for 31 seconds (closes the floor). When Trigger B is detected: - Wait 0 seconds, then activate relay 8 for 31 seconds (opens the floor). - Wait 32 seconds, then activate relay 2 for 17 seconds (lowers the TV). - Wait 50 seconds, then activate relay 7 for 31 seconds (closes the floor). http://picasaweb.google.dk/lh/photo/pRdbHOJ-4G-vtVX6WZqOuA?feat=directlink

DIGITAL INPUT 1 or 2 ON, TRIGGER A Relay 8 Delay 1 Delay 7

*

Relay 1

32 sec

* 50 sec

Relay 7 81 sec

DIGITAL INPUT 1 or 2 OFF, TRIGGER B Relay 8 Delay 2 Delay 7 32 sec

Relay 2

*

* 50 sec

http://www.lintronic.dk

Open floor Raise TV Close floor

Relay 7 81 sec

*

= a 1 second time lap, allowing the floor to rest before TV starts moving.

Open floor Lower TV Close floor

LINTRONIC RELAY 208

Configuration

Click 'On' to test the timing of the relay. The timing specified in Active1/Active2 is used as parameter allowing you to fine-tune the timing without saving to the RELAY 208 board all the time. When you are happy with the timing then click 'SAVE TO RELAY 208'. Check 'BOARD TIMING' to use/test the timing already saved in the board.

http://www.lintronic.dk

LINTRONIC RELAY 208

Configuration

'GetFromComputer' and 'SaveToComputer', retrieves/stores the project from/to the computer. 'Get from RELAY 208' and 'Save to RELAY 208' retrieves/stores the project into the relay 208. 'Save to RELAY 208' also automatically saves to the computer. Both 'SaveToComputer' and 'Save to RELAY 208' will evaluate your data when saving. If a Delay1, Active1, Delay2, Active2 timing is blank it will be set to '0,0,0,0'. If all four Delay1, Active1, Delay2, Active2 timings are '0,0,0,0' then Active will be unchecked. http://www.lintronic.dk

LINTRONIC RELAY 208

Operation by computer Function/Mode: 01-32 up/down and 01-64 on/off RELAY 208 can be controlled by RS232 commands: Use command 039 with a set of parameters to control the relays on-time: 500000000000000000000001 Repeat Units Seconds Minutes Hours Relay Number Function Relay control 12 volt dc

Contact LinTronic for details. G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

http://www.lintronic.dk

COM1

123

LINTRONIC RELAY 208

Operation by Numbers Function/Mode: 01-32 up/down Mode 01-32 was designed for control of curtains and other motors. In this mode the relays are paired together 2 by 2: Motor 1 = Relay 1 and 2 Motor 2 = Relay 3 and 4 Motor 3 = Relay 5 and 6 Motor 4 = Relay 7 and 8 LIGHT 1 UP LIGHT 1 DOWN LIGHT 2 UP LIGHT 2 DOWN LIGHT 3 UP LIGHT 3 DOWN LIGHT 4 UP LIGHT 3 DOWN

stops relay 2 if active, and then controls relay 1 (if Active and set for Numbers). stops relay 1 if active, and then controls relay 2 (if Active and set for Numbers). stops relay 4 if active, and then controls relay 3 (if Active and set for Numbers). stops relay 3 if active, and then controls relay 4 (if Active and set for Numbers). stops relay 6 if active, and then controls relay 5 (if Active and set for Numbers). stops relay 5 if active, and then controls relay 6 (if Active and set for Numbers). stops relay 8 if active, and then controls relay 7 (if Active and set for Numbers). stops relay 7 if active, and then controls relay 8 (if Active and set for Numbers).

Note: If you click up/down when the motor is already running up/down, it will stop.

Relay control

LIGHT

TV

LIGHT RADIO

SAT

DVD

CD

VTAPE RECORD ATAPE

2

8

9

4

5

6

1

2

3

TEXT

0

MENU

3

GO

LIST STOP

>>

>

0

>

1

6

7

>

5

4

9

>

1 through 32

8

>>

Relay number

7

>

Up

>>

>

>>

Down

GO

BANG & OLUFSEN

http://www.lintronic.dk

EXIT

LINTRONIC RELAY 208

Operation by Numbers Function/Mode: 01-64 On/Off Mode 01-64 was designed for individual control of the relays. LIGHT x UP LIGHT x DOWN

controls relay x on (if Active and set for Numbers). controls relay x off (if Active and set for Numbers).

Relay control

LIGHT

TV

LIGHT RADIO

SAT

DVD

CD

VTAPE RECORD ATAPE

2

8

9

4

5

6

1

2

3

TEXT

0

MENU

3

GO

LIST STOP

>>

>

0

>

1

6

7

>

5

4

9

>

1 through 64

8

>>

Relay number

7

>

On

>>

>

>>

Off

GO

BANG & OLUFSEN

http://www.lintronic.dk

EXIT

LINTRONIC RELAY 208

Operation by Colors Function/Mode: 01-32 up/down Mode 01-32 was designed for control of curtains and other motors. In this mode the relays are paired together 2 by 2: Motor 1 = Relay 1 and 2 Motor 2 = Relay 3 and 4 Motor 3 = Relay 5 and 6 Motor 4 = Relay 7 and 8 LIGHT RED SHORT LIGHT RED LONG LIGHT GREEN SHORT LIGHT GREEN LONG LIGHT YELLOW SHORT LIGHT YELLOW LONG LIGHT BLUE SHORT LIGHT BLUE LONG

stops relay 2 if active, and then controls relay 1 (if Active and set for Colors). stops relay 1 if active, and then controls relay 2 (if Active and set for Colors). stops relay 4 if active, and then controls relay 3 (if Active and set for Colors). stops relay 3 if active, and then controls relay 4 (if Active and set for Colors). stops relay 6 if active, and then controls relay 5 (if Active and set for Colors). stops relay 5 if active, and then controls relay 6 (if Active and set for Colors). stops relay 8 if active, and then controls relay 7 (if Active and set for Colors). stops relay 7 if active, and then controls relay 8 (if Active and set for Colors).

Note: A short activation will stop the current up/down.

Relay control

LIGHT

TV

LIGHT RADIO

SAT

DVD

CD

VTAPE RECORD ATAPE

3 up/stop 3 down

8

9

4

5

6

1

2

3

TEXT

0

MENU

LIST

>

STOP

4 up/stop 4 down

BANG & OLUFSEN

http://www.lintronic.dk

>>

>

>

1 up/stop 1 down

GO

>>

>> Long activation is Down

>>

Short activation is Up or Stop

>

>

>

>

2 up/stop 2 down

7

EXIT

LINTRONIC RELAY 208

Operation by Colors Function/Mode: 01-64 on/off Mode 01-64 was designed for individual control of the relays. LIGHT RED SHORT LIGHT RED LONG LIGHT GREEN SHORT LIGHT GREEN LONG LIGHT YELLOW SHORT LIGHT YELLOW LONG LIGHT BLUE SHORT LIGHT BLUE LONG

controls relay 1 On (if Active and set for Colors). controls relay 2 On (if Active and set for Colors). controls relay 3 On (if Active and set for Colors). controls relay 4 On (if Active and set for Colors). controls relay 5 On (if Active and set for Colors). controls relay 6 On (if Active and set for Colors). controls relay 7 On (if Active and set for Colors). controls relay 8 On (if Active and set for Colors).

Relay control

LIGHT

TV

LIGHT RADIO

SAT

DVD

CD

VTAPE RECORD ATAPE

9

4

5

6

1

2

3

TEXT

0

MENU

>

8

>> LIST

>

STOP

>

7 on 8 on

BANG & OLUFSEN

http://www.lintronic.dk

>>

>

>>

>>

1 on 2 on

GO

>

>

Note: In this mode you cannot stop the relays by the colors. The relays must be able to time out or be turned off by for example BEO5 commands or digitail inputs.

5 on 6 on

>

3 on 4 on

7

EXIT

LINTRONIC RELAY 208

Operation by BEO5 Function/Mode: 01-32 up/down and 01-64 on/off The BEO5 will control the relays directly without concidering the mode - provided the relays is Active and set for BEO5.

G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8

Relay 4, 20 seconds Relay 7, 12 seconds Relay 5, 32 seconds

1

2

3

4

C A R

C A R

C A R

C A R

COM1

123

Please observe: If you use some of the relays to control ac motors, it is strongly recommended that you turn off the BEO5 control of these relays to prevent unwanted diredct control of these relays which might destroy your ac motor in case both up and down are activated at the same time. Relays not taking part of ac motor control can freelay be used for direct control (light, etc.)

http://www.lintronic.dk

LINTRONIC RELAY 208

Operation by BEO5 Function/Mode: 01-32 up/down and 01-64 on/off G B A 2 1

COM2

GND 12V

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

TT-IR-8087030

COM1

123

RELAY 208 is designed to work perfectly with the BEO5 remote control. BEO5 includes some new Control and Function commands. With a 2-command combination, you can instruct the RELAY 208 to activate a specific relay for a specific time. Example: CONTROL 5 - FUNCTION 20 - activates relay no. 5 for 20 seconds. This makes it very easy to set up your BEO5 to control the RELAY 208 in virtually any way you want. Perfect for control of lights, curtains, projector screens, etc. when you want enter or leave a Cinema/Theater mode. Ofcourse you can also configure the BEO5 to send out the number and color commands mentioned for the BEO4.

http://www.lintronic.dk

LINTRONIC RELAY 208

Operation by BEO5 Function/Mode: 01-32 up/down and 01-64 on/off

CONTROL COMMANDS Control 0 = All relays Control 1 = Relay 1 Control 2 = Relay 2 Control 3 = Relay 3 Control 4 = Relay 4 Control 5 = Relay 5 Control 6 = Relay 6 Control 7 = Relay 7 Control 8 = Relay 8

http://www.lintronic.dk

FUNCTION COMMANDS Function 1 = On for 1 second Function 2 = On for 2 seconds ... Function 30 = On for 30 seconds Function 31 = On constantly Function 32 = Off constantly Function 33 = Toggle On/Off Function 34 = Reserved Function 35 = Reserved Function 36 = Reserved Function 37 = Toggle "Input 1" Function 38 = Toggle "Input 2"

LINTRONIC RELAY 208

BEOLIVING BeoSystem

Theater In

Theater Out

Relay 208

5 volt, Off DigOut 2

Gnd, On 5 volt, Off

DigOut 1

Gnd, On

Gnd

Gnd

The BeoSystem holds two digital outputs. When the system enters the Theater/Cinema mode, the two digital outputs both become active (ground). The BeoSystem is easily setup like this: First Digital Output 1 is activated (ground), then a programmable delay expires and finally the Digital Output 2 becomes active (ground). When leaving Theater/Cinema mode, the two digital outputs both become in-active (5 volt). First Digital Output 1 becomes in-activate (5 volt), then a programmable delay expires and finally the Digital Output 2 becomes in-active (5 volt). The RELAY 208 can be configured to react to these digital signals and activate the relays to control light systems, a projector or screen lift, etc. etc. If you have specific ideas we are willing to create special firmware which controls your devices as you need.

http://www.lintronic.dk

LINTRONIC RELAY 208

BEOLIVING BeoSystem OUPUT 2

GND

7

5

G B A 2 1

COM2

GND 12V

OUPUT 1 6

C A R

C A R

6

5

C A R 7

C A R 8 1

2

3

4

C A R

C A R

C A R

C A R

Quick-adjust the on-time for relay 3, 4, 7, 8 (default 3 seconds): - activate and hold switch 2 - count the seconds (blinks) - Release switch 2

COM1

123

BEOSYSTEM Cinema mode On When Digital Output 1 goes low (active), then relay 1 and relay 2 are activated (ON - no timeout). Relay 3 is activated for the programmed time (default 3 seconds). When Digital Output 2 goes low (active), then relay 5 and relay 6 are activated (ON - no timeout). Relay 7 is activated for the programmed time (default 3 seconds). Cinema mode Off When Digital Output 1 goes high (in-active), then relay 1 and relay 2 are de-activated (Off). Relay 4 is activated for the programmed time (default 3 seconds). When Digital Output 2 goes high (in-active), then relay 5 and relay 6 are de-activated (Off). Relay 8 is activated for the programmed time (default 3 seconds). http://www.lintronic.dk

LINTRONIC RELAY 208

Reserved

COM1

http://www.lintronic.dk

C A R GND 12V

123

IR receiver 2

screw box to the wall

COM2

89 mm

188 mm

C A R C A R C A R

4

G B A 2 1

3

C A R

7

2

C A R

6

1

C A R

IR receiver 1

5

C A R

screw box to the wall

8

Cabinet, top view

LINTRONIC RELAY 208

Cabinet, drilling wholes You can drill holes in the top or in the side.

http://www.lintronic.dk

13 mm holes

minimum distance 25 mm

minimum distance 25 mm