respiratory catalog - Treen Safety

2 downloads 163 Views 6MB Size Report
peel-away windows, respirator wipes and storage bag. Cartridges not .... [pdf] WorkSafe BC. Available at: https://www.wo
RESPIRATORY CATALOG

RESPIRATORY PROTECTION

Respiratory Selection Guide Disposable Respirators Reusable Respirators- 3MTM Gas and Vapor Cartridges Filters Reusable Respirators- North Gas and Vapor Cartridges Filters Escape Solutions Fit Testing Establishing a Respiratory Program Assigned protection factors

3-5 6 7 8 9 10 11 12 13 14-15 16 17

Hierarchy of Respiratory Protection

17

www.treensafety.com

Respiratory Catalog

RESPIRATORY SELECTION GUIDE- NORTH

www.treensafety.com

Respiratory Catalog

3

RESPIRATORY SELECTION GUIDE- NORTH

www.treensafety.com

Respiratory Catalog

4

R E S P I R A T O R Y S E L E C T I O N G U I D E - 3 M TM OSHA/CSA MAXIMUM CONCENTRATION Under the PEL/ Nuisance Level

OSHA/CSA REQUIREMENT 3MTM PPE SOLUTION

No respirator required

Nuisance Disposable Dust Mask

Exposures up to Disposable Filtering Face1000 times the pieces PEL Reusable Air Purifying Half Mask Respirators (APR)

8210 N95, 8511 N95, 9211

Exposures up to 25 times the PEL

Loose-Fitting Facepiece

M107, M3075-057

Exposures up to 50 times the PEL

Reusable Air Purifying Half Mask Respirators (with PAPR or CF-SAR)

6000, 7500

Reusable Air Purifying Full Facepiece Respirators (APR)*

6700 DIN, 7800

Exposures up to Reusable Air Purifying Full 1000 times the Facepiece Respirators (with PEL PAPR or CF-SAR) Hoods (fit factor of 10,000)

65009L, 6000, 7500, FF400, 7800

6700 DIN, 7800

5-657, M-407

www.treensafety.com

Respiratory Catalog

5

DISPOSABLE RESPIRATORS

SKU

9210+ N95

Description

Stock

5011.013.001

9210+ Particulate respirator disp N95, Flat fold, aura

Yes

5011.014.001

9211+ Particulate respirator disp N95, Flat fold, w/ valve aura

Yes

9211+ N95

SKU

8210N95

Description

Stock

5011.010.001

8210 respirator disp N95

Yes

5012.004.001

2200 N95 M/L respirator disp N95

Yes

5011.016.001

8240 respirator disp R95

No

2200N95

8240 R95 SKU

8210VN95

Description

Stock

5011.015.001

8210V Respirator Disp N95 w/ valve

Yes

5011.011.001

210V Respirator Disp N95 w/ valve

Yes

5012.001.00S

2301N95 S Respirator Disp N95 w/ valve

5012.001.001

2300N95 M/L Respirator Disp N95 w/ valve

No Yes

8511N95

2301N95-S SKU

Description

Stock

5011.007.001

8214 Respirator Disp N95 w/valve/ faceseal

Yes

5010.009.001

14110094CC Dust mask nuisance

Yes

5003.005.001

14110394 M/L Respirator Disp N95 w/ valve SAF-T-FIT Plus N1125

Yes

8214 N95 14110094CC

14110394

www.treensafety.com

Respiratory Catalog

6

REUSABLE RESPIRATORS RESPIRATORS FULL FACE - 3MTM

3MTM Full Facepiece 6000 Series

3MTM Ultimate FX FF-400 Series

Reusable 3M full-face covering respirator with silicone/thermoplastic elastomer, large lens, centre adapter, Cool Flow™ exhalation valve, APR/SA/PAPR modes, 4-point harness and bayonet connection.

FF-400 Full face respirator 3M Ultimate FX large lens with scotchgard coating bonded silicone gaskets, six strap head harness, soft, silicone nose cup & faceseal.

3MTM Full Facepiece 7800S Series Reusable full-face covering respirator with silicone faceseal for maximum comfort, large lens, APR/SA modes and 6-point harness.

Product Code Size

Stock

Product Code Size

Stock

Product Code

Size

Stock

6700

Yes

FF-401

No

7800S

Small

No

Medium

No

Large

No

Small

Small

6800

Medium

Yes

FF-402

Medium

No

7800S

6900

Large

Yes

FF-403

Large

No

7800S

RESPIRATORS HALF MASK - 3M

3MTM 6000 Series

3MTM 6500QL Series

3MTM 7500 Series

Reusable half-face covering respirator with thermoplastic elastomer, 4-point harness and 2 lateral bayonet connections.

3MTM 6500 Series

Resilient silicone faceseal helps Reusable half-face covering respira- The 3M™ 6500QL Series delivers tor with Cool Flow™ exhalation valve, comfort, durability and stability with a provide comfort, durability, and stability silicone, 4-point harness, 2 lateral firm, lightly textured silicone faceseal with a soft but firm seal. Proprietary bayonet connections and soft seal- and strong body construction. Adjust- Cool Flow valve helps reduce heat and ing surface. able head harness assembly, valve moisture. Exhalation valve cover helps cover design, new quick latch drop- direct exhaled breath and moisture down mechanism, silicone face seal, downward to reduce fogging of eyeProduct Size Stock bayonet connection. wear and grinding and welding shields.

Product Code

Size

Stock

6100

Small

Yes

7501

Small

Yes

6200

Medium

Yes

7502

Medium

Yes

Size

Stock

Stock

Large

Yes

Product Code

Size

6300

Product Code

7503

Large

Yes

6501QL

Small

No

6501

Small

Yes

6502QL

Medium

Yes

6502

Medium

Yes

6503OL

Large

Yes

6503

Large

Yes

Code

www.treensafety.com

Respiratory Catalog

7

GAS AND VAPOR CARTRIDGES

CL

CD

MA

FM

HF

MV

Stock

Mercury Vapor

Hydrogen Flouride

AM

Formaldehehyde

HS

Filter Type & Efficiency

MSA Cartridge Description

Product Code

OV

6001

Yes

OV/ P100

60921

No

AG

6002

Yes

AG/P100

60922

No

OV/AG

6003

Yes

OV/AG/ P100

60923

Yes

AM

6004

Yes

AM/P100

60924

No

FORM

6005

No

FORM/ P100

60925

No

MG

6006

Yes

MG/P100

60926

Yes

HG

6009S

No

HG/ P100

60929S

No

www.treensafety.com

HC

Methylamine

Hydrogen Chloride

Chlorine Dioxide

Sulfur Dioxide SD

Ammonia

OV

Hydrogen Sulfide

Color Coding

Chlorine

Organic Vapor

Acid Gases

P100

Respiratory Catalog

8

FILTERS FILTERS-3MTM

2091 Particulate Filter

2097 Particulate Filter P100

2096 Particulate Filter

SKU: 5006.003.001 Stocked Item

SKU: 5006.001.001 Stocked Item

SKU: 5006.007.001 Non-Stocked Item

Pancake particulate filter optimal usage during welding, metal pouring and pharmaceuticals handling. NIOSH approved for environments containing certain oil and non-oil based particles. 2/pack.

Pancake particulate filter optimal usage during welding, metal pouring, pharmaceuticals handling, chemical manufacturing and undercoating. Nuisance level organic vapour relief. 2/pack.

NIOSH approved for environments containing certain oil and non-oil based particles. recommended for relief against nuisance levels of acid gases. P100 particulate filter. Nuisance level Acid Gas. Use with 3M™ Reusable Respirators. Recommended for Cleaning, Demolition, Facility Maintenance, Grinding, Painting, Sanding, Welding.

2291 Advanced Particulate Filter

2296 Advanced Particulate Filter

2297 Advanced Particulate

SKU: 5006.027.001 Non-Stocked Item

SKU: 5006.036.001 Non-Stocked Item

SKU: 5006.028.001 Stocked Item

Longer lasting P100 particulate filter provides easier breathing. NIOSH approved for environments containing certain oil and non-oil based particles. Use with 3M™ Respirators 5000 Series or 3M™ Cartridge 6000 Series with 3M™ Adapter 502, or 3M™ Half and Full Facepieces 6000, 7000 and FF-400 Series with bayonet filter holders.

Exceptional 99.97%filter efficiency meets NIOSH P100-series test criteria. Advanced Electret Media (AEM) provides lightweight, easy breathing comfort. Versatile protection against many oil and non-oil based particulate contaminants. Exterior netting increases durability for a longer lasting filter.

Longer lasting P100, nuisance organic vapor relief particulate filter provides easier breathing. Use with 3M™ Respirators 5000 Series or 3M™ Cartridge 6000 Series with 3M™ Adapter 502, or 3M™ Half and Full Facepieces 6000, 7000 and FF-400 Series with bayonet filter holders.

5N11 Particulate Filter N95 SKU: 5006.022.001 Stocked Item

501 Filter Retainer SKU: 5006.023.001 Stocked Item

5P71 P95 Filter SKU: 5006.026.001 Stocked Item

7093 Filter P100 SKU: 5006.012.001 Non-Stocked Item

NIOSH approved particulate filter for environments containing certain non-oil based particles. Use with 3M™ 5000 series respirators or 6000 series cartridges and 501 filter retainer. 10/box.

This filter retainer is used to hold 3M™ particulate filters 5N11 and 5P71/07194 (AAD) in place on top of 5000 series respirators and 6000 series cartridges.

The 3M™ Particulate Filter 5P71, P95 offers simplicity and ease of use while helping to provide reliable worker protection against certain oil and non-oil containing aerosols.

Exceptional 99.97% filter efficiency meets NIOSH P100-series test criteria. Plastic filter encasement designed for high heat or wet applications.

www.treensafety.com

Respiratory Catalog

9

REUSABLE RESPIRATORS RESPIRATORS FULL FACE - NORTH

5400 Series Full Facepiece

RU6500 Series Full Facepiece

7600 Series Full Facepiece

Reusable elastomeric full face respirator with oral nasal cup, chin cup, latex-free, polycarbonate scratch resistant lens with 200º field of vision and is PAPR or supplied air (SA) adaptable. Comes with peel-away windows, respirator wipes and storage bag. Cartridges not included.

RU6500 full face respirator, silicone, 5Point harness strap, wide viewing area, polycarbonate lens, enhanced head harness, deep threaded cartridge connector, S,M & L

760008A full face respirator, silicone, dual cartridge type, with five strap headband S & M/L (2 Sizes Only)

Product Code Size

Stock

Product Code

Size

Stock

Product Code Size

Stock

54001

Yes

RU65001

Small

No

760008AS

Small

No

RU65001

Medium

No

760008A

No

RU65001

Large

No

Medium/ Large

Medium/ Large

RESPIRATORS HALF FACE - NORTH

5500 Series Half Mask

7700 Series Premium Silicone Half Mask

Reusable non-allergenic elastomeric/silicone blend half face respirator, contoured sealing flange, dual cartridge connectors, PAPR or supplied air (SA) adaptable, dual elasticity head straps, latex-free. Cartridges are not included.

Non-allergenic silicone, contoured sealing flange and cradle suspension system, dual cartridge connectors, PAPR or supplied air (SA) adaptable, dual elasticity headstraps, latex-free. Cartridges not included.

Product Code

Size

Stock

Product Code

Size

Stock

Small

Yes

550030S

Small

Yes

770030S

550030M

Meduin

Yes

770030M

Meduin

Yes

550030L

Large

Yes

770030L

Large

Yes

www.treensafety.com

Respiratory Catalog

10

GAS AND VAPOR CARTRIDGES

Color Coding

OV

CL

SD

CD

HS

MA

FM

HF

MV

Stock

Mercury Vapor

Hydrogen Flouride

Formaldehehyde

Methylamine

Ammonia AM

Filter Type & Efficiency

MSA Cartridge Description

Product Code

OV

N75001L

Yes

OV

7581P100L

Yes

AG

N75002L

No

AG

7582P100L

No

OV/AG

N75003L

No

OV/AG

7583P100L

Yes

AM/MA

N75004L

No

AM/MA

7584P100L

No

Multi Gas

75SCL

Yes

Multi Gas

75SCP100L

Yes

AG

N750052L

No

AG

75852P100L

No

www.treensafety.com

HC

Hydrogen Sulfide

Hydrogen Chloride

Chlorine Dioxide

Sulfur Dioxide

Chlorine

Organic Vapor

Acid Gases

P100

Respiratory Catalog 11

RESPIRATOR CARTRIDGES AND FILTERS - NORTH

75FFP100 N Series Filter

75FFP100NL Pancake Filter

SKU: 5003.023.001 Non-Stocked Item

SKU: 5003.022.001 Stocked Item

P100 low profile, flexible pancake filter. Cartridges P100 low profile, flexible pancake filter providing for use with 5500 and 7700 Series half masks, and relief from nuisance levels of organic vapors, 5400 and 7600 Series full facepieces. 2 per pack. acid gases and ozone. 2/pack.

7580 P100 Particulate Filter SKU: 5002.005.001 Stocked Item P100 particulate filter; 99.97% minimum filter efficiency for all particulates. 2/pack.

7506 N95 Non-Oil Particulate Filter

7506R95 Particulate Filter

SKU: 5003.025.001 Stocked Item

SKU: 5003.028.001 Non-Stocked Item SKU: 5003.006.001 Stocked Item

Particulate filter with 95% filter efficiency for non-oil based aerosol particulates. 10/box.

Particulate filter with 95% filter efficiency for all particulates, R95 oil degrading, 10/box.

Filter Retainer for 7506N95, 7506N99 and 7506R95 Filters when used with gas and vapor cartridges. Includes two ea N750027 filter covers and two ea N750038 filter spiders.

N750037 Filter Retainer Kit

N750035 Adapter for Flexible Filters

N750029 Shower Cap

SKU: 5003.006.037

N750036 Filter Retainer Kit

Non-Stocked Item SKU: 5003.006.035 Non-Stocked Item SKU: 5003.007.001 Non-Stocked Item

Filter Retainer for 7506N95, 7506N99 and 7506R95 Filters when used directly on facepiece. Includes two ea N750027 filter covers and two ea N750015 filter holders.

Adapter for 75FFP100 filter. Attaches filter to chemical cartridges.

www.treensafety.com

Shower Cap for 7580P100 Filter, black. Protects filter from water spray during abatement & decontamination; plus sparks and slag during welding and grinding operations.

Respiratory Catalog

12

ESCAPE SOLUTIONS

7902 Acid Gas Mouthbit Respirator

7904 Ammonia Mouthbit Respirator

North Mouthbit Respirators

CBRN Escape Hood

SKU: 5010.002.001 Stocked Item

SKU: 5004.188.001 Non-Stocked Item SKU: 5018.008.001

Mouthbit respirators offer a quick and economical method to escape non-IDLH emergency situations. Large, soft and flexible nose pads hold securely without pinching. Wider nose clip fits a variety of facial types. Silicone mouthpiece is comfortable and easy to hold in the mouth during escape. Packed in sealable plastic bag, carrying bag sold separately (79BAG)

NIOSH CAP 2 Escape hood offers minimum of 30 minutes escape from many contaminants. Dual cartridge design is ergonomically balanced for increased comfort. Features anti-claustrophobic clear hood and contoured butyl neck dam for easy donning and better fit.

Survivair Panther™ Hip-Pac PD-SAR 5 Minute Non-Stocked Item

Respirators and Hip-Pacs provide the highest level of interchangability, protection and ease of operation. Full facepiece PD SARs offer the simplicity and reliability of Survivair Panther™ mask-mounted regulators. Hip-Pacs enhance protection in environments immediately dangerous to life or health (IDLH), with 5-, 10-, or 15-minute escape cylinders. Survivair Panther™ PD SARs and Hip-Pacs provide significant cost savings and convenience as part of fully interchangable respirator systems. 2216 psig, aluminium, without Quick-Disconnect.

975647 Escape Breathing Apparatus-10 SKU: 5018.010.001

Non-Stocked Item

Escape breathing apparatus, 10-minute cylinder (3000 psig, aluminum), hood

www.treensafety.com

Respiratory Catalog

13

FIT TESTING Fit testing is the process to ensure that contaminated air cannot leak into a respirator and be inhaled. A respirator must form a good shield; even eyeglass frames, head coverings or beard, sideburns, subtle must not come between your respirator and your skin. The U.S. Occupational Safety and Health Administration (OSHA) regulation 29 CFR 1910.134 and the Canadian Standards Association (CSA) standard Z94.4-11 require that all fit testing be performed in the negative pressure mode. Masks that are dedicated to a positive pressure respirator, such as a supplied air respirator or self-contained breathing apparatus that are only used in a positive pressure mode, must either be converted to negative pressure masks with the use of adapters, or negative pressure masks with the same sealing surface must be used as a surrogate. CSA STANDARD Z94.4-11 SECTION 9.1.7 Tight-fitting respirators shall be tested only in the negative-pressure mode regardless of the mode of operation in which the respirator is to be used. Note: This can be accomplished by temporarily converting the user’s face piece into negative-pressure mode or by using a surrogate negative-pressure air-purifying respirator with identical sealing surface. WHEN TO DO A FIT TEST? • Before you use your respirator the first time • At least once a year • If you experience physical changes, such as weight gain or loss or broken facial bones, that could affect the respirator’s fit HOW DO YOU DO A FIT TEST? • Be clean shaven • Put on your respirator as you would for your usual work conditions- for example, your straps should be as tight as they usually are when you are working • Wear all the other equipment (such as glasses or goggles, hearing protection, and hard hat) you will have to wear when you are wearing your respirator. • Seal check your respirator, using either a positive or negative pressure check. • The tester will put a test agent that causes a taste, irritation, or smell into the air around the seal on your respirator (you may have to wear a special hood). Breathe in and report whether you can taste, feel, or smell the test agent. Instead, the tester may use special measuring instruments to determine whether there is any leakage into your mask • Sign the fit-test form to indicate that the test has been done. MISCONCEPTIONS OF FIT TESTING One of the biggest misconceptions about fit testing is that it is not required for disposable respirators. This is untrue. Whether a worker is wearing a disposable or reusable respirator, all tight-fitting respirators must be tested per CSA Z94.4. Another common misconception is that tight-fitting respirators attached to powered or supplied air systems don’t require fit testing. This is also untrue. Respirators used with powered and supplied air respiratory systems require fit testing in negative pressure mode so that they can be properly used in powered and supplied air mode.

Treen Safety conducts qualitative or quantitative fit testing for negative pressure respirators. Please contact us at 604-2534588 or visit www.treensafety.com to learn more about Fit Testing or to book an appointment. Reference: Fit Testing Your Respirator. (2009). [pdf] WorkSafe BC. Available at: https://www.worksafebc.com/en/health-safety/toolsmachinery-equipment/personal-protective-equipment-ppe/types/respiratory-protection [Accessed 29 Sep. 2017].

www.treensafety.com

Respiratory Catalog

14

FIT TESTING

Fit Test Collar FT-15 Fit Test Solution FT-32 SKU: 5005.998.015 Non-Stocked ItemSKU: 5005.998.032 Stocked Item

Fit Test Solution - Sweet FT-12

3M™ Collar FT-15 is used with the 3M™ Qualitative Fit Test Apparatus FT-10 and FT-30 to provide a secure hood environment. Can be used to check face-to-respirator seal on any particulate respirator or gas/vapor respirator with a particulate prefilter.

The 3M™ Fit Test Solution FT-12 is a replacement part for fit test kit FT-10 (sweet). 55mls.

Meet the performance criteria for fit testing respirators under the current OSHA Standard for Respirator Protection: 29 CFR 1910.134, Appendix A

SKU: 5005.998.012 Stocked Item

Fit Test Apparatus (Bitter)

770040 Qualitative Irritant Smoke Fit Test FT-13 Nebulizer

SKU: 5005.998.030 Stocked Item

SKU: 5004.042.001 Non-Stocked Item

Meets the performance criteria for fit testing The qualitative smoke fit test kit is used to respirators under the current OSHA Standard keep workplace in compliance with OSHA for Respirator Protection: 29 CFR 1910.134, and OHS laws. The kit comes in a deluxe Appendix A. Test kits and accessories decarrying case. signed to help your organization meet OSHA fit testing requirements for respirators. The products can be used to check face-to-respirator seal on any particulate respirator or gas/vapor respirator with a particulate prefilter.

VeriFit® Irritant Smoke Kit SKU: 5004.061.001 Stocked Item

Smoke tube kit, 10 tubes per pack.

SKU: 5005.998.013 Stocked Item The 3M™ Nebulizer FT-13 is used with the 3M™ Qualitative Fit Test Apparatus FT-10, FT-30 and the 3M™ Training and Fit Testing Case FT-20.

770047/ C Irritant Smoke Tubes SKU: 5004.155.001 Non-Stocked Item For Qualitative Fit Test Kit. 6/pack.

www.treensafety.com

Respiratory Catalog

15

ESTABLISHING A RESPIRATORY PROGRAM Establishing an Effective Respiratory Protection Program OSHA 29CFR 1910.134 CSA Z94.4-11 A written Respiratory Protection Program is required whenever there is a respiratory hazard, or potential for a respiratory hazard, at a worksite. It is also required in the U.S. when respirators are used in environments where the contaminant levels are below the permissible exposure limit (PEL). The following is a very brief overview of the minimum requirements set forth by the U.S. Occupational Safety and Health Administration (OSHA) regulation 29 CFR 191.134 and Canadian Standards Association (CSA) standard Z94.4-11. For a more thorough review of Program requirements, visit honeywellsafety.com, the OSHA website (for US), or the CSA and local Worksafe websites (for Canada). In addition to a thorough understanding of OSHA and CSA Regulations, you must also understand and comply with any additional State or Provincial regulations, plus any industry- and contaminantspecific regulations that apply to your worksite. The first step in establishing a Respiratory Protection Program is to understand all the respiratory hazards and potential hazards at your worksite. This includes knowing the contaminants and their concentrations and whether there is an IDLH or potential IDLH environment. The Program Administrator must have a thorough understanding of OSHA or CSA Regulations, State or Provincial regulations, plus any industryand contaminantspecific regulations that apply to the worksite. Program Requirements 1. The program must be written, with worksite-specific procedures, and updated as necessary. 2. The Program must be managed by a trained Program Administrator. 3. When contaminants are below the PEL, employers may still allow workers to wear respirators on a voluntary basis.i 4. Respirator training must be provided at no cost to the employee, and must be performed annually. 5. The employer shall provide a medical evaluation to determine the employee’s ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. 6. A respirator shall be provided to each employee at no cost to the employee, and is applicable and suitable for the pur pose intended. 7. Fit Testing is required prior to initial use, whenever a different respirator facepiece is used and at least annually thereaf ter by OSHA, and every two years by CSA. OSHA and CSA require quantitative fit testing for air-purifying full facepieces that will be worn in environments where a contaminant’s concentration is between 10 times and 50 times the PEL. CSA also requires quantitative fit testing for self-contained breathing apparatus. 8. The Respirator Program must include procedures for proper use during an emergency. 9. Establish your worksite procedures and schedules for cleaning, disinfecting, storing, inspecting, repairing, discarding and maintaining respirators. 10. If air-purifying or powered air-purifying respirators are used for protection from gases or vapors, the cartridges must be equipped with an End-of-Service Life Indicator (ESLI), or there must be a cartridge change schedule established. Refer to the Honeywell esLife at honeywellsafety.com for cartridge service life calculations. 11. If an atmosphere-supplying respirator is used, such as a continuous flow or pressure demand airline, there must be procedures in place to assure that the breathing air is grade D or better (US) or meets requirements of Z180.1 (CSA). Resources • CSA Z 94.4-11 • NIOSH Decision Logic • OSHA 29 CFR 1910.134 • OSHA “Small Entity Compliance Guide for the Respiratory Protection Standard” • OSHA MedCert • ANSI Z88.2 “American National Standard for Respiratory Protection”

www.treensafety.com

Respiratory Catalog

16

ASSIGNED PROTECTION FACTORS

HIERARCHY OF RESPIRATORY PROTECTION

www.treensafety.com

Respiratory Catalog

17

Burnaby Head Office

#207 - 2999 Underhill Avenue, Burnaby BC V5A 3C2 [email protected] Phone: 604 253 4588 1 800 665 1564

Kitimat Office

620 Commercial Ave, Kitimat,V8C 2C5 [email protected] Phone: 250 632 4634

Web: www.treensafety.com