peel-away windows, respirator wipes and storage bag. Cartridges not .... [pdf] WorkSafe BC. Available at: https://www.wo
RESPIRATORY CATALOG
RESPIRATORY PROTECTION
Respiratory Selection Guide Disposable Respirators Reusable Respirators- 3MTM Gas and Vapor Cartridges Filters Reusable Respirators- North Gas and Vapor Cartridges Filters Escape Solutions Fit Testing Establishing a Respiratory Program Assigned protection factors
3-5 6 7 8 9 10 11 12 13 14-15 16 17
Hierarchy of Respiratory Protection
17
www.treensafety.com
Respiratory Catalog
RESPIRATORY SELECTION GUIDE- NORTH
www.treensafety.com
Respiratory Catalog
3
RESPIRATORY SELECTION GUIDE- NORTH
www.treensafety.com
Respiratory Catalog
4
R E S P I R A T O R Y S E L E C T I O N G U I D E - 3 M TM OSHA/CSA MAXIMUM CONCENTRATION Under the PEL/ Nuisance Level
OSHA/CSA REQUIREMENT 3MTM PPE SOLUTION
No respirator required
Nuisance Disposable Dust Mask
Exposures up to Disposable Filtering Face1000 times the pieces PEL Reusable Air Purifying Half Mask Respirators (APR)
8210 N95, 8511 N95, 9211
Exposures up to 25 times the PEL
Loose-Fitting Facepiece
M107, M3075-057
Exposures up to 50 times the PEL
Reusable Air Purifying Half Mask Respirators (with PAPR or CF-SAR)
6000, 7500
Reusable Air Purifying Full Facepiece Respirators (APR)*
6700 DIN, 7800
Exposures up to Reusable Air Purifying Full 1000 times the Facepiece Respirators (with PEL PAPR or CF-SAR) Hoods (fit factor of 10,000)
65009L, 6000, 7500, FF400, 7800
6700 DIN, 7800
5-657, M-407
www.treensafety.com
Respiratory Catalog
5
DISPOSABLE RESPIRATORS
SKU
9210+ N95
Description
Stock
5011.013.001
9210+ Particulate respirator disp N95, Flat fold, aura
Yes
5011.014.001
9211+ Particulate respirator disp N95, Flat fold, w/ valve aura
Yes
9211+ N95
SKU
8210N95
Description
Stock
5011.010.001
8210 respirator disp N95
Yes
5012.004.001
2200 N95 M/L respirator disp N95
Yes
5011.016.001
8240 respirator disp R95
No
2200N95
8240 R95 SKU
8210VN95
Description
Stock
5011.015.001
8210V Respirator Disp N95 w/ valve
Yes
5011.011.001
210V Respirator Disp N95 w/ valve
Yes
5012.001.00S
2301N95 S Respirator Disp N95 w/ valve
5012.001.001
2300N95 M/L Respirator Disp N95 w/ valve
No Yes
8511N95
2301N95-S SKU
Description
Stock
5011.007.001
8214 Respirator Disp N95 w/valve/ faceseal
Yes
5010.009.001
14110094CC Dust mask nuisance
Yes
5003.005.001
14110394 M/L Respirator Disp N95 w/ valve SAF-T-FIT Plus N1125
Yes
8214 N95 14110094CC
14110394
www.treensafety.com
Respiratory Catalog
6
REUSABLE RESPIRATORS RESPIRATORS FULL FACE - 3MTM
3MTM Full Facepiece 6000 Series
3MTM Ultimate FX FF-400 Series
Reusable 3M full-face covering respirator with silicone/thermoplastic elastomer, large lens, centre adapter, Cool Flow™ exhalation valve, APR/SA/PAPR modes, 4-point harness and bayonet connection.
FF-400 Full face respirator 3M Ultimate FX large lens with scotchgard coating bonded silicone gaskets, six strap head harness, soft, silicone nose cup & faceseal.
3MTM Full Facepiece 7800S Series Reusable full-face covering respirator with silicone faceseal for maximum comfort, large lens, APR/SA modes and 6-point harness.
Product Code Size
Stock
Product Code Size
Stock
Product Code
Size
Stock
6700
Yes
FF-401
No
7800S
Small
No
Medium
No
Large
No
Small
Small
6800
Medium
Yes
FF-402
Medium
No
7800S
6900
Large
Yes
FF-403
Large
No
7800S
RESPIRATORS HALF MASK - 3M
3MTM 6000 Series
3MTM 6500QL Series
3MTM 7500 Series
Reusable half-face covering respirator with thermoplastic elastomer, 4-point harness and 2 lateral bayonet connections.
3MTM 6500 Series
Resilient silicone faceseal helps Reusable half-face covering respira- The 3M™ 6500QL Series delivers tor with Cool Flow™ exhalation valve, comfort, durability and stability with a provide comfort, durability, and stability silicone, 4-point harness, 2 lateral firm, lightly textured silicone faceseal with a soft but firm seal. Proprietary bayonet connections and soft seal- and strong body construction. Adjust- Cool Flow valve helps reduce heat and ing surface. able head harness assembly, valve moisture. Exhalation valve cover helps cover design, new quick latch drop- direct exhaled breath and moisture down mechanism, silicone face seal, downward to reduce fogging of eyeProduct Size Stock bayonet connection. wear and grinding and welding shields.
Product Code
Size
Stock
6100
Small
Yes
7501
Small
Yes
6200
Medium
Yes
7502
Medium
Yes
Size
Stock
Stock
Large
Yes
Product Code
Size
6300
Product Code
7503
Large
Yes
6501QL
Small
No
6501
Small
Yes
6502QL
Medium
Yes
6502
Medium
Yes
6503OL
Large
Yes
6503
Large
Yes
Code
www.treensafety.com
Respiratory Catalog
7
GAS AND VAPOR CARTRIDGES
CL
CD
MA
FM
HF
MV
Stock
Mercury Vapor
Hydrogen Flouride
AM
Formaldehehyde
HS
Filter Type & Efficiency
MSA Cartridge Description
Product Code
OV
6001
Yes
OV/ P100
60921
No
AG
6002
Yes
AG/P100
60922
No
OV/AG
6003
Yes
OV/AG/ P100
60923
Yes
AM
6004
Yes
AM/P100
60924
No
FORM
6005
No
FORM/ P100
60925
No
MG
6006
Yes
MG/P100
60926
Yes
HG
6009S
No
HG/ P100
60929S
No
www.treensafety.com
HC
Methylamine
Hydrogen Chloride
Chlorine Dioxide
Sulfur Dioxide SD
Ammonia
OV
Hydrogen Sulfide
Color Coding
Chlorine
Organic Vapor
Acid Gases
P100
Respiratory Catalog
8
FILTERS FILTERS-3MTM
2091 Particulate Filter
2097 Particulate Filter P100
2096 Particulate Filter
SKU: 5006.003.001 Stocked Item
SKU: 5006.001.001 Stocked Item
SKU: 5006.007.001 Non-Stocked Item
Pancake particulate filter optimal usage during welding, metal pouring and pharmaceuticals handling. NIOSH approved for environments containing certain oil and non-oil based particles. 2/pack.
Pancake particulate filter optimal usage during welding, metal pouring, pharmaceuticals handling, chemical manufacturing and undercoating. Nuisance level organic vapour relief. 2/pack.
NIOSH approved for environments containing certain oil and non-oil based particles. recommended for relief against nuisance levels of acid gases. P100 particulate filter. Nuisance level Acid Gas. Use with 3M™ Reusable Respirators. Recommended for Cleaning, Demolition, Facility Maintenance, Grinding, Painting, Sanding, Welding.
2291 Advanced Particulate Filter
2296 Advanced Particulate Filter
2297 Advanced Particulate
SKU: 5006.027.001 Non-Stocked Item
SKU: 5006.036.001 Non-Stocked Item
SKU: 5006.028.001 Stocked Item
Longer lasting P100 particulate filter provides easier breathing. NIOSH approved for environments containing certain oil and non-oil based particles. Use with 3M™ Respirators 5000 Series or 3M™ Cartridge 6000 Series with 3M™ Adapter 502, or 3M™ Half and Full Facepieces 6000, 7000 and FF-400 Series with bayonet filter holders.
Exceptional 99.97%filter efficiency meets NIOSH P100-series test criteria. Advanced Electret Media (AEM) provides lightweight, easy breathing comfort. Versatile protection against many oil and non-oil based particulate contaminants. Exterior netting increases durability for a longer lasting filter.
Longer lasting P100, nuisance organic vapor relief particulate filter provides easier breathing. Use with 3M™ Respirators 5000 Series or 3M™ Cartridge 6000 Series with 3M™ Adapter 502, or 3M™ Half and Full Facepieces 6000, 7000 and FF-400 Series with bayonet filter holders.
5N11 Particulate Filter N95 SKU: 5006.022.001 Stocked Item
501 Filter Retainer SKU: 5006.023.001 Stocked Item
5P71 P95 Filter SKU: 5006.026.001 Stocked Item
7093 Filter P100 SKU: 5006.012.001 Non-Stocked Item
NIOSH approved particulate filter for environments containing certain non-oil based particles. Use with 3M™ 5000 series respirators or 6000 series cartridges and 501 filter retainer. 10/box.
This filter retainer is used to hold 3M™ particulate filters 5N11 and 5P71/07194 (AAD) in place on top of 5000 series respirators and 6000 series cartridges.
The 3M™ Particulate Filter 5P71, P95 offers simplicity and ease of use while helping to provide reliable worker protection against certain oil and non-oil containing aerosols.
Exceptional 99.97% filter efficiency meets NIOSH P100-series test criteria. Plastic filter encasement designed for high heat or wet applications.
www.treensafety.com
Respiratory Catalog
9
REUSABLE RESPIRATORS RESPIRATORS FULL FACE - NORTH
5400 Series Full Facepiece
RU6500 Series Full Facepiece
7600 Series Full Facepiece
Reusable elastomeric full face respirator with oral nasal cup, chin cup, latex-free, polycarbonate scratch resistant lens with 200º field of vision and is PAPR or supplied air (SA) adaptable. Comes with peel-away windows, respirator wipes and storage bag. Cartridges not included.
RU6500 full face respirator, silicone, 5Point harness strap, wide viewing area, polycarbonate lens, enhanced head harness, deep threaded cartridge connector, S,M & L
760008A full face respirator, silicone, dual cartridge type, with five strap headband S & M/L (2 Sizes Only)
Product Code Size
Stock
Product Code
Size
Stock
Product Code Size
Stock
54001
Yes
RU65001
Small
No
760008AS
Small
No
RU65001
Medium
No
760008A
No
RU65001
Large
No
Medium/ Large
Medium/ Large
RESPIRATORS HALF FACE - NORTH
5500 Series Half Mask
7700 Series Premium Silicone Half Mask
Reusable non-allergenic elastomeric/silicone blend half face respirator, contoured sealing flange, dual cartridge connectors, PAPR or supplied air (SA) adaptable, dual elasticity head straps, latex-free. Cartridges are not included.
Non-allergenic silicone, contoured sealing flange and cradle suspension system, dual cartridge connectors, PAPR or supplied air (SA) adaptable, dual elasticity headstraps, latex-free. Cartridges not included.
Product Code
Size
Stock
Product Code
Size
Stock
Small
Yes
550030S
Small
Yes
770030S
550030M
Meduin
Yes
770030M
Meduin
Yes
550030L
Large
Yes
770030L
Large
Yes
www.treensafety.com
Respiratory Catalog
10
GAS AND VAPOR CARTRIDGES
Color Coding
OV
CL
SD
CD
HS
MA
FM
HF
MV
Stock
Mercury Vapor
Hydrogen Flouride
Formaldehehyde
Methylamine
Ammonia AM
Filter Type & Efficiency
MSA Cartridge Description
Product Code
OV
N75001L
Yes
OV
7581P100L
Yes
AG
N75002L
No
AG
7582P100L
No
OV/AG
N75003L
No
OV/AG
7583P100L
Yes
AM/MA
N75004L
No
AM/MA
7584P100L
No
Multi Gas
75SCL
Yes
Multi Gas
75SCP100L
Yes
AG
N750052L
No
AG
75852P100L
No
www.treensafety.com
HC
Hydrogen Sulfide
Hydrogen Chloride
Chlorine Dioxide
Sulfur Dioxide
Chlorine
Organic Vapor
Acid Gases
P100
Respiratory Catalog 11
RESPIRATOR CARTRIDGES AND FILTERS - NORTH
75FFP100 N Series Filter
75FFP100NL Pancake Filter
SKU: 5003.023.001 Non-Stocked Item
SKU: 5003.022.001 Stocked Item
P100 low profile, flexible pancake filter. Cartridges P100 low profile, flexible pancake filter providing for use with 5500 and 7700 Series half masks, and relief from nuisance levels of organic vapors, 5400 and 7600 Series full facepieces. 2 per pack. acid gases and ozone. 2/pack.
7580 P100 Particulate Filter SKU: 5002.005.001 Stocked Item P100 particulate filter; 99.97% minimum filter efficiency for all particulates. 2/pack.
7506 N95 Non-Oil Particulate Filter
7506R95 Particulate Filter
SKU: 5003.025.001 Stocked Item
SKU: 5003.028.001 Non-Stocked Item SKU: 5003.006.001 Stocked Item
Particulate filter with 95% filter efficiency for non-oil based aerosol particulates. 10/box.
Particulate filter with 95% filter efficiency for all particulates, R95 oil degrading, 10/box.
Filter Retainer for 7506N95, 7506N99 and 7506R95 Filters when used with gas and vapor cartridges. Includes two ea N750027 filter covers and two ea N750038 filter spiders.
N750037 Filter Retainer Kit
N750035 Adapter for Flexible Filters
N750029 Shower Cap
SKU: 5003.006.037
N750036 Filter Retainer Kit
Non-Stocked Item SKU: 5003.006.035 Non-Stocked Item SKU: 5003.007.001 Non-Stocked Item
Filter Retainer for 7506N95, 7506N99 and 7506R95 Filters when used directly on facepiece. Includes two ea N750027 filter covers and two ea N750015 filter holders.
Adapter for 75FFP100 filter. Attaches filter to chemical cartridges.
www.treensafety.com
Shower Cap for 7580P100 Filter, black. Protects filter from water spray during abatement & decontamination; plus sparks and slag during welding and grinding operations.
Respiratory Catalog
12
ESCAPE SOLUTIONS
7902 Acid Gas Mouthbit Respirator
7904 Ammonia Mouthbit Respirator
North Mouthbit Respirators
CBRN Escape Hood
SKU: 5010.002.001 Stocked Item
SKU: 5004.188.001 Non-Stocked Item SKU: 5018.008.001
Mouthbit respirators offer a quick and economical method to escape non-IDLH emergency situations. Large, soft and flexible nose pads hold securely without pinching. Wider nose clip fits a variety of facial types. Silicone mouthpiece is comfortable and easy to hold in the mouth during escape. Packed in sealable plastic bag, carrying bag sold separately (79BAG)
NIOSH CAP 2 Escape hood offers minimum of 30 minutes escape from many contaminants. Dual cartridge design is ergonomically balanced for increased comfort. Features anti-claustrophobic clear hood and contoured butyl neck dam for easy donning and better fit.
Survivair Panther™ Hip-Pac PD-SAR 5 Minute Non-Stocked Item
Respirators and Hip-Pacs provide the highest level of interchangability, protection and ease of operation. Full facepiece PD SARs offer the simplicity and reliability of Survivair Panther™ mask-mounted regulators. Hip-Pacs enhance protection in environments immediately dangerous to life or health (IDLH), with 5-, 10-, or 15-minute escape cylinders. Survivair Panther™ PD SARs and Hip-Pacs provide significant cost savings and convenience as part of fully interchangable respirator systems. 2216 psig, aluminium, without Quick-Disconnect.
975647 Escape Breathing Apparatus-10 SKU: 5018.010.001
Non-Stocked Item
Escape breathing apparatus, 10-minute cylinder (3000 psig, aluminum), hood
www.treensafety.com
Respiratory Catalog
13
FIT TESTING Fit testing is the process to ensure that contaminated air cannot leak into a respirator and be inhaled. A respirator must form a good shield; even eyeglass frames, head coverings or beard, sideburns, subtle must not come between your respirator and your skin. The U.S. Occupational Safety and Health Administration (OSHA) regulation 29 CFR 1910.134 and the Canadian Standards Association (CSA) standard Z94.4-11 require that all fit testing be performed in the negative pressure mode. Masks that are dedicated to a positive pressure respirator, such as a supplied air respirator or self-contained breathing apparatus that are only used in a positive pressure mode, must either be converted to negative pressure masks with the use of adapters, or negative pressure masks with the same sealing surface must be used as a surrogate. CSA STANDARD Z94.4-11 SECTION 9.1.7 Tight-fitting respirators shall be tested only in the negative-pressure mode regardless of the mode of operation in which the respirator is to be used. Note: This can be accomplished by temporarily converting the user’s face piece into negative-pressure mode or by using a surrogate negative-pressure air-purifying respirator with identical sealing surface. WHEN TO DO A FIT TEST? • Before you use your respirator the first time • At least once a year • If you experience physical changes, such as weight gain or loss or broken facial bones, that could affect the respirator’s fit HOW DO YOU DO A FIT TEST? • Be clean shaven • Put on your respirator as you would for your usual work conditions- for example, your straps should be as tight as they usually are when you are working • Wear all the other equipment (such as glasses or goggles, hearing protection, and hard hat) you will have to wear when you are wearing your respirator. • Seal check your respirator, using either a positive or negative pressure check. • The tester will put a test agent that causes a taste, irritation, or smell into the air around the seal on your respirator (you may have to wear a special hood). Breathe in and report whether you can taste, feel, or smell the test agent. Instead, the tester may use special measuring instruments to determine whether there is any leakage into your mask • Sign the fit-test form to indicate that the test has been done. MISCONCEPTIONS OF FIT TESTING One of the biggest misconceptions about fit testing is that it is not required for disposable respirators. This is untrue. Whether a worker is wearing a disposable or reusable respirator, all tight-fitting respirators must be tested per CSA Z94.4. Another common misconception is that tight-fitting respirators attached to powered or supplied air systems don’t require fit testing. This is also untrue. Respirators used with powered and supplied air respiratory systems require fit testing in negative pressure mode so that they can be properly used in powered and supplied air mode.
Treen Safety conducts qualitative or quantitative fit testing for negative pressure respirators. Please contact us at 604-2534588 or visit www.treensafety.com to learn more about Fit Testing or to book an appointment. Reference: Fit Testing Your Respirator. (2009). [pdf] WorkSafe BC. Available at: https://www.worksafebc.com/en/health-safety/toolsmachinery-equipment/personal-protective-equipment-ppe/types/respiratory-protection [Accessed 29 Sep. 2017].
www.treensafety.com
Respiratory Catalog
14
FIT TESTING
Fit Test Collar FT-15 Fit Test Solution FT-32 SKU: 5005.998.015 Non-Stocked ItemSKU: 5005.998.032 Stocked Item
Fit Test Solution - Sweet FT-12
3M™ Collar FT-15 is used with the 3M™ Qualitative Fit Test Apparatus FT-10 and FT-30 to provide a secure hood environment. Can be used to check face-to-respirator seal on any particulate respirator or gas/vapor respirator with a particulate prefilter.
The 3M™ Fit Test Solution FT-12 is a replacement part for fit test kit FT-10 (sweet). 55mls.
Meet the performance criteria for fit testing respirators under the current OSHA Standard for Respirator Protection: 29 CFR 1910.134, Appendix A
SKU: 5005.998.012 Stocked Item
Fit Test Apparatus (Bitter)
770040 Qualitative Irritant Smoke Fit Test FT-13 Nebulizer
SKU: 5005.998.030 Stocked Item
SKU: 5004.042.001 Non-Stocked Item
Meets the performance criteria for fit testing The qualitative smoke fit test kit is used to respirators under the current OSHA Standard keep workplace in compliance with OSHA for Respirator Protection: 29 CFR 1910.134, and OHS laws. The kit comes in a deluxe Appendix A. Test kits and accessories decarrying case. signed to help your organization meet OSHA fit testing requirements for respirators. The products can be used to check face-to-respirator seal on any particulate respirator or gas/vapor respirator with a particulate prefilter.
VeriFit® Irritant Smoke Kit SKU: 5004.061.001 Stocked Item
Smoke tube kit, 10 tubes per pack.
SKU: 5005.998.013 Stocked Item The 3M™ Nebulizer FT-13 is used with the 3M™ Qualitative Fit Test Apparatus FT-10, FT-30 and the 3M™ Training and Fit Testing Case FT-20.
770047/ C Irritant Smoke Tubes SKU: 5004.155.001 Non-Stocked Item For Qualitative Fit Test Kit. 6/pack.
www.treensafety.com
Respiratory Catalog
15
ESTABLISHING A RESPIRATORY PROGRAM Establishing an Effective Respiratory Protection Program OSHA 29CFR 1910.134 CSA Z94.4-11 A written Respiratory Protection Program is required whenever there is a respiratory hazard, or potential for a respiratory hazard, at a worksite. It is also required in the U.S. when respirators are used in environments where the contaminant levels are below the permissible exposure limit (PEL). The following is a very brief overview of the minimum requirements set forth by the U.S. Occupational Safety and Health Administration (OSHA) regulation 29 CFR 191.134 and Canadian Standards Association (CSA) standard Z94.4-11. For a more thorough review of Program requirements, visit honeywellsafety.com, the OSHA website (for US), or the CSA and local Worksafe websites (for Canada). In addition to a thorough understanding of OSHA and CSA Regulations, you must also understand and comply with any additional State or Provincial regulations, plus any industry- and contaminantspecific regulations that apply to your worksite. The first step in establishing a Respiratory Protection Program is to understand all the respiratory hazards and potential hazards at your worksite. This includes knowing the contaminants and their concentrations and whether there is an IDLH or potential IDLH environment. The Program Administrator must have a thorough understanding of OSHA or CSA Regulations, State or Provincial regulations, plus any industryand contaminantspecific regulations that apply to the worksite. Program Requirements 1. The program must be written, with worksite-specific procedures, and updated as necessary. 2. The Program must be managed by a trained Program Administrator. 3. When contaminants are below the PEL, employers may still allow workers to wear respirators on a voluntary basis.i 4. Respirator training must be provided at no cost to the employee, and must be performed annually. 5. The employer shall provide a medical evaluation to determine the employee’s ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. 6. A respirator shall be provided to each employee at no cost to the employee, and is applicable and suitable for the pur pose intended. 7. Fit Testing is required prior to initial use, whenever a different respirator facepiece is used and at least annually thereaf ter by OSHA, and every two years by CSA. OSHA and CSA require quantitative fit testing for air-purifying full facepieces that will be worn in environments where a contaminant’s concentration is between 10 times and 50 times the PEL. CSA also requires quantitative fit testing for self-contained breathing apparatus. 8. The Respirator Program must include procedures for proper use during an emergency. 9. Establish your worksite procedures and schedules for cleaning, disinfecting, storing, inspecting, repairing, discarding and maintaining respirators. 10. If air-purifying or powered air-purifying respirators are used for protection from gases or vapors, the cartridges must be equipped with an End-of-Service Life Indicator (ESLI), or there must be a cartridge change schedule established. Refer to the Honeywell esLife at honeywellsafety.com for cartridge service life calculations. 11. If an atmosphere-supplying respirator is used, such as a continuous flow or pressure demand airline, there must be procedures in place to assure that the breathing air is grade D or better (US) or meets requirements of Z180.1 (CSA). Resources • CSA Z 94.4-11 • NIOSH Decision Logic • OSHA 29 CFR 1910.134 • OSHA “Small Entity Compliance Guide for the Respiratory Protection Standard” • OSHA MedCert • ANSI Z88.2 “American National Standard for Respiratory Protection”
www.treensafety.com
Respiratory Catalog
16
ASSIGNED PROTECTION FACTORS
HIERARCHY OF RESPIRATORY PROTECTION
www.treensafety.com
Respiratory Catalog
17
Burnaby Head Office
#207 - 2999 Underhill Avenue, Burnaby BC V5A 3C2
[email protected] Phone: 604 253 4588 1 800 665 1564
Kitimat Office
620 Commercial Ave, Kitimat,V8C 2C5
[email protected] Phone: 250 632 4634
Web: www.treensafety.com