SCDOT SUE Sheets

6 downloads 14546 Views 2MB Size Report
NONPOTTABLE WATER SYMBOLS ... WATER BLOW OFF VALVE .... utility is positioned in three dimensions, the designer can often make small adjustments in ...
FED. RD.

ROAD STATE

COUNTY

FILE NO.

DIV. NO. 3

ROUTE NO.

S.C.

NA

NA

NA

SHEET NO.

NA

SUE LEGEND AND NOTES SYM ABV

ELECTRIC SYMBOLS DESCRIPTION

TELECOMMUNICATION SYMBOLS SYM ABV DESCRIPTION

ETM

ELECTRICAL TRANSFORMER

T

TB

TELEPHONE BOOTH

E

EMH

ELECTRICAL MAN HOLE

C

TVP

CABLE TV PEDESTAL

E

EHH

ELECTRICAL HAND HOLE

L

TLC

SUBSCRIBER LOOP CARRIER (aka SLICK)

E

EPP

ELECTRIC PEDESTAL

T

TPP

TELEPHONE PEDESTAL

E

EBX

ELECTRIC BOX

T

TMH

TELEPHONE MAN HOLE

ESG

ELECTRIC SWITCH GEAR BOX

F

TFOH

FIBER OPTIC HAND HOLE

EVT

ELECTRIC VAULT

T

THH

TELEPHONE HAND HOLE

EGL

GROUND / LANDSCAPE LIGHT

C

TVHH

CABLE TV HAND HOLE

EAB

ELECTRIC AIR BRAKE

T

TBX

TELEPHONE BOX

ERO

ELECTRIC RESIDENTAL OUTLET

X

TXB

SPLICE BOX

TRP

TELEPHONE REPEATER

C

TVB

CABLE TV BOX

T

TUV

UNDERGROUND TELEPHONE VAULT

E

B

POLE SYMBOLS DESCRIPTION

SYM ABV

m

PSP

SIGNIFICANT POLE (STEEL, CONCRETE, ETC)

PP

ELECTRIC, COMBINATION POLE

T

UTP

UNDERGROUND TELEPHONE PEDESTAL

PMP

METER POLE

C

UTV

UNDERGROUND CABLE TV PEDESTAL

PLT

TRANSMISSION LINE POLE

PLP

AREA LIGHT POLE

M

WM

WATER METER

PTF

TRAFFIC SIGNAL POLE

V

WV

WATER VALVE

POP

OTHER USE POLE

M

WMW

WATER MONITORING WELL

PCT

CELL PHONE TOWER

WFH

FIRE HYDRANT

PTP

TELEPHONE POLE

W

WMH

WATER MAN HOLE

PGP

GUY POLE

A

WAR

WATER AIR RELEASE VALVE

L

O

WATER SYMBOLS

TRAFFIC CONTROL SYMBOLS

W

WVB

WATER VALVE BOX

S

TFV

TRAFFIC SIGNAL CONTROL VAULT

F

WFC

FIRE DEPARTMENT CONNECTION

S

TFHH

TRAFFIC CONTROL HAND HOLE

P

WBP

WATER BACKFLOW PREVENTER

S

TFJ

TRAFFIC SIGNAL JUNCTION BOX

GAS SYMBOLS SYM

DESCRIPTION

G

GM

GAS METER

G

GVC

GAS VALVE CAP

GMH

GTP

S

GTF

S

U

e

L

MUE

SAR

SEWER AIR RELEASE VALVE SEWER STEP TANK

I

EOI EORI AATUR AATFI EATUR NAP NAC

END OF INFORMATION END OF RECORDED INFORMATION UTILITY ABANDONED ACCORDING TO UTLILITY RECORDS UTILITY ABANDONED ACCORDING TO FIELD INSPECTION EMPTY ACCORDING TO UTILITY RECORDS NO ASSOCIATED PIPING FOUND FROM STRUCTURE NO ASSOCIATED CABLES FOUND FROM STRUCTURE

DBR DATFI EATFI PR MT CAP GR

DIRECT BURIED DEPICTED ACCORDING TO FIELD INSPECTION EMPTY ACCORDING TO FIELD INSPECTION PAIR EMPTY CAPACITY GROUND

SEWER GRINDER / PUMP STATION

SSV

SEWER VALVE

C DI S P FO CI S CO PV VY TC SWC AC TF GW CNT

COPPER DUCTILE IRON STEEL PLASTIC FIBER OPTIC CAST IRON STEEL CONCRETE PVC VYLON TERRA COTTA STEEL WRAPPED COATED ASBESTOS CEMENT TRAFFIC SIGNAL CABLE GUY WIRE CONDUIT

E W G PUPS T TV, C FO S FS DB TF UNK HP ST F R I DB TNL CA

ELECTRIC (POWER) UNDERGROUND WATER UNDERGROUND GAS PALMETTO UTILIY PROTECTION SERVICES TELEPHONE, TELECOMMUNICATION CABLE TELEVISION FIBER OPTIC SANITARY SEWER FORCED SANITARY SEWER, FORCE MAIN DUCT BANK TRAFFIC CONTROL UTILITY UNKNOWN UTILITY HYDROGEN PEROXIDE STEAM LINE FUEL / PETROLEUM LINE RECLAIMED WATER / SLURRY LINE IRRIGATION LINE DUCT BANK TUNNEL GASES MATERIAL

IRRIGATION CONTROL VALVE

ICB

IRRIGATION CONTROL BOX

S

E1 THRU E10

ELECTRIC DESIGNATED

E1 THRU E10

TRAFFIC CONTROL DESIGNATED

TF1 THRU TF5

TELEPHONE RECORDED

T1 THRU T10

TELEPHONE DESIGNATED

T1 THRU T10

CABLE TV RECORDED

TV1 THRU TV10

CABLE TV DESIGNATED

TV1 THRU TV10

IRRIGATION RECORDED

I1 THRU I5

IRRIGATION DESIGNATED

I1 THRU I5

SLURRY RECORDED

R1 THRU R5

SLURRY DESIGNATED

R1 THRU R5

GAS RECORDED

G1 THRU G10

GAS DESIGNATED

G1 THRU G10

FUEL/PETROL RECORDED

F1 THRU F5

FUEL/PETROL DESIGNATED

F1 THRU F5

STEAM DESIGNATED

ST1 THRU ST5

COMPRESSED GASES RECORDED

CA1 THRU CA5

COMPRESSED GASES DESIGNATED

CA1 THRU CA5

WATER RECORDED

W1 THRU W10

WATER DESIGNATED

W1 THRU W10

FS1 THRU FS10

FORCED SEWER DESIGNATED

FS1 THRU FS10

-AERIAL UTILITY LINES ARE CONSIDERED AS LEVEL ’C’. -UTILITY OWNER INFORMATION SHOWN ON UTILITY TITLE SHEET.

S

TEST HOLE

IRH

COMBINATION LINE DEPICTION CODES SHOW COMBINED LEVEL C & D SUE WILL INCLUDE THE FOLLOWING LEVEL QUALITY CODES: LINE SHOWN DEPICTS QUALITY LEVEL C

UNK MT SCEG MT

UTILITY OWNER "Y" (B)

UTILITY LINES THAT REQUIRE MORE DETAILED INFORMATION ON THE PLAN SHEET CAN BE LABELED WITH THE SUPPLIMENTAL UTILITY LINE LABEL (SUL): E1,T1,TV1

500PR DBR AATUR S 12.3>

UNIQUE UTILITY IDENTIFIER (UUI)

UNK MT

UNK MT

OWNER REF. ABBREVIATION

UNK MT

11.8> S

OWNERSHIP CODES WILL REFERENCED ON THE TITLE/OWNER SHEET AND THE UTILITY & POLE DATA SHEET.

T

UCT

NEW / RELOCATE TELECOMMUNICATION PEDESTAL

TF1 THRU TF5

TRAFFIC CONTROL

G

UCG

NEW / RELOCATE GAS STRUTURE

W1 THRU W10

WATER

E

. UCE

. NEW / RELOCATE ELECTRIC STRUCTURE

G1 THRU G10

GAS

S

. UCS

S

. UCF

. NEW / RELOCATE TRAFFIC STRUCTURE

F1 THRU F5

U

. UCU

NEW / RELOCATE . MISC STRUCTURE

OH1 THRU OH20

NEW / RELOCATE

. SEWER

.

.

GW

DB1 THRU DB5 TNL

UNKOWN DESIGNATED

UNK

SWEEP LIMIT

SUE

SL

LOAM

ZL

SILT

CL SC

CLAY LOAM SILTY CLAY

SILT

DB1 THRU DB5 M1 THRU M5

U SHEET LINEWORK WILL BE USED WHEN UTILITY RELOCATION PLANS ARE INCLUDED IN THE PLAN SET. ALL U SHEET UUI LINES WILL BE DETAILED ON THE U SHEET DATA SHEET. "MISCELANEOUS" UUI U SHEET LINEWORK CAN BE USED FOR ANY UTILITY NOT REPRESENTED WITH A RELOCATION UUI.

SOIL COMBINATION CHART SILTY

FS1 THRU FS10

CABLE TV

FORCED SEWER FUEL / PETROLEUM AERIAL UTILITIES DUCT BANK MISCELLANEOUS

REMOVED UTILITIES ABANDONED

DUCT BANK DESIGNATED UTILITY TUNNEL

STRUCTURE

U SHEET PLAN NOTES

DB1 THRU DB5

CLAY

ELECTRIC

.

DUCT BANK RECORDED

SANDY

-UTILITY POLE DATA INFORMATION SHOWN ON UTILITY & POLE

E1 THRU E10

TELEPHONE

REMOVED

Ta

Tr

TVa

TVr

CABLE TV

Ea

Er

ELECTRIC

TFa

TFr

TRAFFIC CONTROL

Wa

Wr

WATER

Ga

Gr

GAS

FSa

FSr

Fa

Fr

ON U SHEETS, EXISTING UTILITIES ARE DEPICTED ON A GREYSCALE.

Z

TELEPHONE

FORCED SEWER FUEL / PETROLEUM

OHr

AERIAL UTILITIES

DBa

DBr

DUCT BANK

Ma

Mr

SAND

ZCL ZC

CLAY LOAM CLAY

SCL

MISCELANEOUS

PROJECT NOTES

C

DATA SHEETS. -TEST HOLE SHOWN ON UTILITY PLAN SHEETS AND DETAILED ON

SURFACE DESCRIPTION LEGEND KEY INTERASPHALT

-HORIZONTAL AND VERTICAL REFERENCED TO PROJECT

A

LOCKING BRICK

I

CONCRETE

C

CONTROL FOUND ON REFERENCE SHEET.

UNK MT

-SERVICES LINES WERE DESIGNATED TO THE SWEEP LIMITS OR

No. OF CONDUITS

(A)



E1

DB1

UTILITY OWNER "X"

T2



MULTIPLE SUE OWNERS CAN BE DEPICTED OWNERSHIP WITH THE FOLLOWING CODES:

(B)

G1

SHEETS.

NEW / RELOCATE WATER STRUCTURE

.

TEST HOLE REFERENCE SHEETS.



(A)

DUCT BANK DIAGRAM





LINE SHOWN DEPICTS QUALITY LEVEL D

IRRIGATION / SPRINKLER HEAD

UCW

OH1 THRU OH20

-DETAILED INFORMATION SHOWN ON UTILITY & POLE DATA

MTH

TV1 THRU TV10

AERIAL UTILITY LINE

M1 THRU M5

LOAM

REMOVE UTILITY POLE

.

MISCELANEOUS DESIGNATED

CLAY

URP

.

M1 THRU M5

-GRAVITY SANITARY SEWER LINES ARE SHOWN AS LEVEL ’C’.

T1 THRU T10

AERIAL SIGNAL LINE

MISCELANEOUS RECORDED

LOAM

NEW / RELOCATED UTILITY POLE

SIG

AERIAL GUY WIRE

SANDY

U SHEET - UTILITY COORDINATION LEGEND DESCRIPTION PROPOSED UTILITY LINES

UCP

W

S1 THRU S10

FORCED SEWER RECORDED

SANITARY SEWER MANHOLE

GENERAL NOTES

Level B. This level involves the use of surface geophysical techniques to determine the existence and horizontal position of underground utilities. This activity is called "designating." Two-dimensional mapping information is obtained. This information is usually sufficient to accomplish preliminary engineering goals. Decisions can be made on where to place storm drainage systems, footers, foundations and other design features in order to avoid conflicts with existing utilities. Slight adjustments in the design can produce substantial cost savings by eliminating utility relocations.

SYM ABV

ST1 THRU ST5

DESIGNATE EACH SANITARY SEWER MANHOLE WITH A SEWER MANHOLE NUMBER (SMN). REFERENCE THIS SMN ON THE UTILITY DATA SHEET AND LIST ELEVATIONS.

Level C. This level involves surveying visible aboveground utility facilities (e.g., manholes, valve boxes, posts) and correlating this information with existing utility records. When using this information, it is not unusual to find that many underground utilities have been either omitted or erroneously plotted. Its usefulness, therefore, should be confined to rural projects where utilities are not prevalent, or are not too expensive to repair or relocate.

Level A. This level involves the use of nondestructive digging equipment at critical points to determine the precise horizontal and vertical position of underground utilities, as well as the type, size, condition, material and other characteristics. This activity is called "locating." It is the highest level presently available. When surveyed and mapped, precise plan and profile information are available for use in making final design decisions. By knowing exactly where a utility is positioned in three dimensions, the designer can often make small adjustments in elevations or horizontal locations and avoid the need to relocate utilities. Additional information (e.g., utility materials, condition, size, soil contamination, paving thickness) also assists the designer and Utility Company in their decisions.

STEAM RECORDED

GAVITY SEWER

QUALITY LEVEL DEFINITIONS Level D. This level information comes solely from existing utility records. It may provide an overall "feel" for the congestion of utilities, but it is often highly limited in terms of comprehensiveness and accuracy. Its usefulness should be confined to project planning and route selection activities.

TF1 THRU TF5

SEWER MANHOLE NUMBERS (SMN) S001

ELECTRIC RECORDED

TRAFFIC CONTROL RECORDED

GENERAL ABBREVIATIONS

SEWER LIFT STATION

ICV

UTILITY UNIQUE IDENTIFIER LINE-STYLES

MATERIAL ABBREVIATIONS

SEWER CHECK VALVE BOX

NONPOTTABLE WATER SYMBOLS I

UTILITY TERMINI / ENDS

SEWER MAN HOLE

SLS

MISC / UNKNOWN VALVE CAP OR COVER PAVED OR BURIED MANHOLE / CAP

SEWER CLEAN OUT

SGP

S

END OF INFORMATION

MPB

DESCRIPTION

SCV

G

UTILITY WITNESS POST

MUC

POST INDICATOR VALVE

SST

V

GAS LINE TAP FARM

MWP

WPV

SMH

R

GAS LINE TEST POINT

EOI MOI U

WELL HOUSE

SCO

MISC SYMBOLS U

WWH

SYM ABV

GAS PRESSURE REGULATOR

GTP

GTF

W

SEWER SYMBOLS

GAS VENT

GR

GR

WATER BLOW OFF VALVE

GAS MAN HOLE

GVT

GV

WBO

P

ABV

G

B

UTILITY INFORMATION ABBERVIATIONS

PLACE DUCT BANK DIAGRAM ON THE UTILITY & POLE DATA SHEET BELOW THE UTILITY & POLE DATA CHART. NOTE THE UUI OF THE DUCT BANK ON THE DIAGRAM. DEPICT THE CORRECT NUMBER OF CONDUITS IN THE DUCT AND THE USAGE OF EACH. MARK EMPTIES (IF KNOWN) WITH OWNER REFERENCE ABBREVIATION AND "MT".

UTILITY INFORMATION TAGS (UIT)

DISTRUBUTION POINT. -ALL SUBSURFACE UTILITY WORK WAS PERFORMED USING THE ASCE GUIDELINES FOR THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITIY DATA

T001

GROUND

N

SOIL DESCRIPTION LEGEND KEY COMPACTION WATER LEVEL

SOIL TYPE

CI/ASCE 38-02

LOOSE

L

DRY

D

CLAY

C

SOFT

D

MOIST

M

LOAM

L

HARD

H

WET

E

SAND

S

UTILITY POLE ID NUMBER (UPIN)

TAG EACH UTILITY POLE WITH A UTILITY POLE ID WHEN UTILITY APPURTENANCES NEED DESCRIBING, NUMBER (UPIN) STARTING AT THE BEGINNING PLACE A UIT NEXT TO THE CELL OR OUTLINED STATION. REFERENCE UPIN ON THE UTILITY & POLE AREA. PLACE THE INFORMATION ON THE UTILITY DATA SHEET WITH APPROPRIATE INFORMATION. DATA SHEET. DESIGNATE THE UTILITY BY THE OWNER NUMBER AND "T001" CODE IN THE "UTILITY" POLE NUMBER P002 COLUMN. (IE - T2 T001). X

NATURAL

P001

OH3

SOLID

HH

STANDING WATER

WW

SILT

Z

SOUTH CAROLINA DEPARTMENT OF TRANSPORTATION ROAD DESIGN COLUMBIA, SC

South Carolina Department of Transportation

SUBSURFACE UTILITY ENGINEERING LEGEND & NOTES SUElegend.DGN

UTILITY

ALIGNMENT / ROUTE / RD

STATION RANGE

OFFSET RANGE

ITEM IN PLACE

OWNERSHIP

REMARKS / MISC NOTES

ALIGNMENT / ROUTE / RD

POLE

STATION

OFFSET

OWNER

OWNER No

POLE DATA HEIGHT DIAMETER

MATERIAL

REMARKS / MISC NOTES

`

COLUMN UTILITY

POLE

DESCRIPTION a) Reference the Utility Unique Identifier (UUI) b) Reference Sewer Manhole Number (SMN) c) Reference Utility Information Tags (UIT) Reference the Utility Pole ID Number

EXAMPLE

COLUMN

E1, G1, OH15

STATION

S001, SMH‐02

RANGE

U001, U05 P001, P25

Reference the Alignment used for stationing ALIGNMENT Use design alignments when available ROUTE RD

~All geometric data used will be referenced to the project datum~

DESCRIPTION a) Reference the station of the begin & end of linear utility b) Reference the station location of utility appurtenance c) Reference the station location of mahole

OFFSET

a) Reference the offset of the begin & end of linear utility

RANGE

b) Reference the offset location of utility appurtenance c) Reference the offset location of manhole a) Reference utility type, size, & material

MAIN ST.

ITEM IN

MAIN ST RELOC

PLACE

b) Reference the utility appurtenance type c) Reference manhole 

EXAMPLE 01+23 ‐ 45+67 01+23

COLUMN

DESCRIPTION Reference utility owner by name or by Owner Ref Abbr OWNERSHIP From Title Sheet

EXAMPLE LOCAL POWER CO LPC

01+23

Reference Owner Number, Height, Diameter, and Material of pole

15R ‐ 15R 25L

DPC123, 35', 12", WOOD

POLE DATA

25L TELEPHONE, COPPER / GAS 6" DI U/G PEDESTAL SEWER MH

REMARKS

a) Further details including capacity, etc.

MISC NOTES b) List Sewer rims and invert elevations

c) List details and desc, sizes, record information, etc.

RIM=123.45, INV IN=123.45 INV OUT=123.45 RECORDS SHOW INFO

FED. RD.

UTILITY

ALIGNMENT/ ROUTE

STATION RANGE

OFFSET RANGE

W1 8AC

ROUTE

10+00-30+00

30R

ITEM IN PLACE

8"ACP

OWNERSHIP

GCSWA

POLE DATA REMARKS / MISC INFORMATION

GENERALLY INSTALLED 15’ FROM EDGE PAVEMENT

UPIN

POO1

ALIGNMENT/ ROUTE

ROUTE

NORTHING OR STATION

EASTING OR OFFSET

123+00

125 R

12345678

123456789

COUNTY

SHEET FILE NO.

3

NO.

NO.

S.C.

POLE DATA OWNER

OWNER No

SCACAC

RWR1234

HEIGHT

45’

MISC INFORMATION

DIAMETER MATERIAL

12"

WOOD

$$$date$$$$

$$$$$$path$$$$$$$$fi l enam e$$$$$$$$

$$user$$

UTILITY DATA

STATE

DIV. NO.

UTILITY & POLE DATA TABLE DESCRIPTION REV. NO.

BY

DATE

SOUTH CAROLINA

DESCRIPTION OF REVISION

DEPARTMENT OF TRANSPORTATION 4

ROAD DESIGN

COLUMBIA, S.C.

3 2 1

UTILITY AND POLE DATA SHEET

1 1

SCALE 1"=

RTE.

DWG. NO.

PN1

BORDER1_50.DGN

TEST HOLE No. 1 2 3

TYPE OF UTILITY TFO TFO W

UTILITY OWNER BTI BTI

UTILITY MATERIAL P CNT P CNT SEE NOTE

SIZE OR CAPACITY 3 X 2" 3 X 2" SEE NOTE

UTILITY CONDITION GOOD GOOD SEE NOTE

RECORD MATCH NO NO N/A

SURFACE TYPE* NG NG NG

PAVEMENT THICKNESS N/A N/A N/A

SOIL TYPE** S‐M‐C S‐M‐C S‐M‐C

4

TFO

BTI

P CNT

3 X 2"

GOOD

NO

NG

N/A

S‐M‐SC

5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

REFERENCE REFERENCE GRADE MARKER BENCHMARK ELEVATION HUB 12.26' HUB 12.68' HUB 15.85'

HUB

16.61'

TOP OF UTIL. ELEV. 8.21' 7.61' 4.77'

11.87'

BOTTOM OF UTIL. ELEV.

APX CL BEARING

ALIGNMENT US17 US17 US17

STATION 478+27.4 480+61.36 483+02.94

US17

486+04.98

PROJECT LOCATION DATA OFFSET NORTHING 123.53 RT 686132.27 118.93 685981.95 87.27 LT 685669.83

57.00 LT

685503.97

MISC NOTES EASTING 2628141 2627961.68 2627902.86

2627648.62

TEST HOLE REVEALVED 3 STACKED 2" TELEPHONE (BTI) FIBER OPTIC CONDUITS " UNABLE TO OBTAIN SIZE AND MATERIAL TYPE DUE TO DEPTH, GROUND WATER AND SOIL CONDITIONS. PIPE APPEARS LARGER THAN 24". POSSIBLE CASING FOR WATER. AIR LANCE PROBE AT 7 LOCATIONS (SEE DETAIL BELOW) REVEALED SHAPE (ROUND) AND THE SE & NW SPRINGLINES OF PIPE. TEST HOLE REVEALVED 3 STACKED 2" TELEPHONE (BTI) FIBER OPTIC CONDUITS

REFERENCE

UTILITY OWNER

UTILITY / RUIT

OWNER REF. ABBR.

EXISTING LOCATIONS ALIGNMENT / ROUTE

STATION RANGE

EXISTING OFFSET RANGE

ITEM IN PLACE

ACTION REMARKS RELOCATE ADJUST

AS‐IS

RELOCATION ITEM TO PLACE

RELOCATIONS STATION RANGE

OFFSET RANGE

MISC NOTES

ITEM PLACED PER PER PLAN

FIELD FIT

REVISION