ScienceDirect Distributed generation technologies ...

4 downloads 396 Views 455KB Size Report
Keywords: distributed generation; renewable energy; micro-hydro; .... A solar cell consists of two or more layers of semiconductor material, the most common ... The thermoelectric and “green” energy producers must have a lower price of their ...
Available online at www.sciencedirect.com

ScienceDirect Procedia Technology 12 (2014) 687 – 692

The 7th International Conference Interdisciplinarity in Engineering (INTER-ENG 2013)

Distributed generation technologies and optimization Lucian Ioan Dulăua,*, Mihail Abrudeanb, Dorin Bicăc a

PhD School, System Engineering, Faculty of Automation and Computer Science, Technical University of Cluj-Napoca, Cluj-Napoca, Romania/ Faculty of Engineering, “Petru Maior” University of Tîrgu-Mureş, Tîrgu-Mureş, Romania b Department of Automation, Faculty of Automation and Computer Science, Technical University of Cluj-Napoca, Cluj-Napoca, Romania c Department of Electrical and Computer Engineering, Faculty of Engineering, “Petru Maior” University of Tîrgu-Mureş, Tîrgu-Mureş, Romania

Abstract This paper describes the main technologies used for distributed generation and the optimization of a system that contains these technologies. The term distributed generation refers to the production of electricity near the consumption place. The distributed generation resources are renewable energies and cogeneration (simultaneous production of heat and electricity). Renewable energy is energy from natural resources such as wind, sunlight, tides, waves, geothermal heat and biomass. The optimization aims to minimize the electricity production costs ensuring that the load is served reliably. © 2013 The Authors. Published by Elsevier B.V. © 2013 The Published by Elsevier Ltd. Open accessofunder CC BY-NC-ND license. Selection andAuthors. peer-review under responsibility of Department Electrical and Computer Engineering, Faculty of Engineering, Selection and University peer-review of the Petru Maior University of Tirgu Mures. “Petru Maior” ofunder Tîrgu responsibility Mureș. Keywords: distributed generation; renewable energy; micro-hydro; photovoltaic panel; wind turbine; optimization

1. Introduction In this paper is presented the main technologies used for distributed generation and the optimization of a system that contains one of these technologies.

* Corresponding author. Tel.: +40-265-233-112. E-mail address: [email protected]

2212-0173 © 2013 The Authors. Published by Elsevier Ltd. Open access under CC BY-NC-ND license. Selection and peer-review under responsibility of the Petru Maior University of Tirgu Mures. doi:10.1016/j.protcy.2013.12.550

688

Lucian Ioan Dulău et al. / Procedia Technology 12 (2014) 687 – 692

The term "distributed generation" (DG) refers to the production of electricity near the consumption place. The distributed generation resources are renewable energies and cogeneration (simultaneous production of heat and electricity) [3]. Renewable energy is energy from natural resources such as wind, sunlight, tides, waves, geothermal heat and biomass [3]. In Table 1 [8] is presented the most commonly used DG technologies and their typical module size. Table 1. Typical available size per module for DG Technology

Typical available size per power module

Combined Cycle Gas Turbine

35 - 400 MW

Internal Combustion Engines

5 kW - 10 MW

Combustion Turbine

1 - 250 MW

Micro-Turbines

35 kW - 1 MW

Fuel Cells, Phos.Acid

200 kW - 2 MW

Fuel Cells, Molten Carbonate

250 kW - 2 MW

Fuel Cells, Proton Exchange

1 - 250 kW

Fuel Cells, Solid Oxide

250 kW - 5 MW

Battery Storage

500 kW - 5 MW

Small Hydro

1 - 100 MW

Micro Hydro

25 kW - 1 MW

Wind Turbine

200 W - 3 MW

Photovoltaic Arrays (PV Arrays)

20 W - 100 kW

Solar Thermal, Central Receiver

1 - 10 MW

Solar Thermal, Lutz System

10 - 80 MW

Biomass Gasification

100 kW - 20 MW

Geothermal

5 - 100 MW

Ocean Energy

100 kW - 5 MW

2. DG technologies 2.1. Micro-hydro Hydropower systems (Fig. 1) use the energy in flowing water to produce electricity or mechanical energy [12]. For run-of-the-river micro-hydro power systems, a portion of a river's water is diverted to a water conveyance channel, pipeline, or pressurized pipeline (penstock) - that delivers it to a turbine or waterwheel. The moving water rotates the wheel or turbine, which spins a shaft. The motion of the shaft can be used for mechanical processes, such as pumping water, or it can be used to power an alternator or generator to generate electricity. [12]

689

Lucian Ioan Dulău et al. / Procedia Technology 12 (2014) 687 – 692

Fig. 1. Small hydro system [2]

The hydraulic power P0 (kW) and the corresponding energy E0(kWh) over an interval time Δt(h) will be [2]: 鶏待 噺 貢 ゲ 訣 ゲ 芸 ゲ 茎待 "岫倦激岻

(1)

継待 噺 貢 ゲ 訣 ゲ 茎待 ゲ ッ建"岫倦激月岻

(2)

鶏庁 噺 考 ゲ 鶏待

(3)

where: H0 – net head (m); Q - the discharge diverted to the power plant (m3/s). The final power (PF) delivered to the network is smaller than the available hydraulic power (P 0) [2]:

where: η - the global efficiency. 2.2. Wind turbine The wind turbine works in the following way: the wind kinetic energy is transmitted to the blades, which drives a shaft coupled to an electric generator that transforms (converts) the wind power into electric energy. [3] The main parts of a wind turbine (Fig. 2) are: rotor, blades, nacelle (contains all major components such as shaft, gearbox and the electric generator) and tower [3]. The power that can be generated by a wind turbine is calculated with the following relationship [3]: 鶏 噺 ど の ゲ 貢 ゲ 畦 ゲ 系椎 ゲ 拳 戴 ゲ 考直 ゲ 考長 "岫激岻

where: ρ - air density [kg/m3]; A - rotor swept area, exposed to the wind (m2); Cp - coefficient of performance (depending on turbine); w - wind speed (m/s); ηg - generator efficiency; ηb - gearbox efficiency.

(4)

690

Lucian Ioan Dulău et al. / Procedia Technology 12 (2014) 687 – 692

Fig. 2. Wind turbine [3]

2.3. Photovoltaic panel The photovoltaic term comes from the Greek language, meaning light (photo) and electric (voltaic). A photovoltaic panel transforms the light from the Sun directly into electric energy. The main components of a photovoltaic panel are the solar cells. [3] A solar cell consists of two or more layers of semiconductor material, the most common being silicon. These layers have a thickness between 0.001 and 0.2 mm and they are doped with chemical elements to form "p" and "n" junctions. When the silicon layer is exposed to light, then the electrons from the material agitate and an electric current will be generated. The current generated by a single cell is small, but series and parallel combinations of these cells can produce currents high enough so they can be used in practice. [3] Depending on the nature of the semiconductor material used in their manufacture (usually silicon), there are three different types of photovoltaic cells: monocrystalline, polycrystalline and amorphous (Fig. 3). [3]

Fig. 3. Types of photovoltaic cells [3] Table 2. The performance of different types of solar cells Material

Efficiency in laboratory conditions

Efficiency in mass production conditions

Monocrystalline silicon

24 %

14...17 %

Polycrystalline silicon

18 %

12...15 %

Amorphous silicon

13 %

5...7 %

691

Lucian Ioan Dulău et al. / Procedia Technology 12 (2014) 687 – 692

To produce electric current, between 36 and 72 solar cells are joined together. Photovoltaic modules consist of photovoltaic circuits sealed in a protective laminate environment. Photovoltaic panels include one or more photovoltaic modules. A photovoltaic array is the complete power generating unit, consisting of any number of modules and photovoltaic panels. [3] The output power of photovoltaic panels can be mathematically expressed as [3]: 鶏 噺 考 ゲ 荊 ゲ 鯨津 "岫激岻

(5)

where: η - efficiency of the panel; I – insolation (the power produced per unit square meter of the panel); Sn - number of panels. 3. Optimization of a DG environment The optimization aims to minimize the electricity production costs ensuring that the load is served reliably. The optimization is done for the system in Fig. 4 using the Neplan software, having the following mathematical model: min {C (P)}

(6)

with the restrictions: PiminiPii Pimax; QiminiQii Qimax; UiminiUii Uimax

(7)

where: C(P)- the cost of generated power (lei/MWh); P- active power generated (MW); Q- reactive power generated (MVAr); U- rated voltage (kV).

Fig. 4. Test system

In Fig. 4 there are three types of generators: hydroelectric (G1 having 72 MW), thermoelectric (G2 having 50 MW) and a wind turbine (G3 having 1 MW). There is also a 100 MW consumer (C1). The cost of generated power is given by the Romanian Energy Regulatory Authority.

692

Lucian Ioan Dulău et al. / Procedia Technology 12 (2014) 687 – 692

The Romanian Energy Regulatory Authority (ANRE) set the average price for different types of energy that I present in table 3 [11]. Table 3. Average prices for different types of energies Energy type

Average price (lei/MWh)

Nuclear energy

142

Hydroelectric energy

125

Thermoelectric energy

190

Producers beneficiaries of the bonus support scheme type that produce electricity from high efficiency cogeneration

189

Producers with dispatchable energy units

189

The calculation is performed by selecting in Neplan the optimal power flow analysis. The results are: 0.702 MW active power losses and a generation cost of 504 (lei/h). Also, the results shows that most of the power is supplied by the hydro generator. The other producers must lower the prices of power delivered in order to have a greater importance in the system. 4. Conclusions Distributed generation technologies had changed many aspects of distribution system operation, design and implementation. By increasing more decentralized systems with smaller generating units connecting directly to the distribution networks near demand consumption, the distribution companies reduce loss in their networks. The thermoelectric and “green” energy producers must have a lower price of their electricity given in the power system in order for the system to be competitive. References [1] Ahmadigorji M., et al. Optimal DG Placement in Distribution systems Using Cost/Worth Analysis, World Academy of Science, Engineering and Technology, 2009ș 25. [2] Balat H. A renewable perspective for sustainable energy development in Turkey: The case of small hydropower plants, Renewable and Sustainable Energy Reviews, Elsevier; 2006. [3] Dulău LJ. Hybrid Wind and Solar Power System, 2nd IFAC Workshop on Convergence of Information Technologies and Control Methods with Power Systems, Poster Session; 2013. [4] Kansal S et al. Optimal placement of distributed generation in distribution networks, International Journal of Engineering, Science and Technology, 2011; 3(3). [5] Padhi P et al. Distributed Generation: Impacts and Cost Analysis, Special Issue of International Journal of Power System Operation and Energy Management, 1(3). [6] Rani PS et al. Optimal Sizing Of Dg Units Using Exact Loss Formula At Optimal Power Factor, International Journal of Engineering Science and Technology, 2012; 4(9). [7] Rosehart W et al. Optimal placement of Distributed Generation, 14th PSCC, 2002. [8] Singh S.N et al. Distributed Generation in Power Systems: An Overview and Key Issues, Indian Engineering Congress, 2009. [9] Sheikhi A et al. Distributed Generation Penetration Impact on Distribution Networks Loss, International Conference on Renewable Energies and Power Quality, 2013. [10] Supriya CS et al. Optimization And Sizing Of A Grid-Connected Hybrid Pv-Wind Energy System, International Journal of Engineering Science and Technology, 2011; 3(5). [11] www.anre.ro - Raport privind preţurile şi cantităţile de energie electrică vândute de producători pe piaţa reglementată de energie electrică (Report on the prices and quantities of electricity sold by producers in the regulated electricity). [12] energy.gov/energysaver/articles/microhydropower-systems.