A: Abbreviation of Haier. B: Abbreviation of Window. C: R-Remote Control. F-
Mechanical Control. D: Nominal cooling capacity(BTU/h) with the first two
numbers ...
Domestic Air Conditioner
SERVICE MANUAL
Models HWR10XC6 Part number: AC-8888-134
Features Top-Discharge Air Flow Ultra Quiet Operation Safty Power Cord EnvicoCleanTM Coil Easy-Access Washable Filter Digital Display&Timer
Serial Number:
Version:00.00
Edition: 2005-12-1
Domestic Air Conditioner
Model: HWR10XC6
Content
1、 Product Code Illumination And Series introduction 2、 Features
---------------------------- 2
-----------------------------------------------------------------------------------------3
3、 Specifications
-------------------------------------------------------------------------------- 4
4、 Safety and Precaution
-----------------------------------------------------------------------5
5、Warning and Cautions
----------------------------------------------------------------------6
6、Net Dimention
---------------------------------------------------------------------------------7
7、Installation and Accessory Parts
-------------------------------------------------------8
8、Parts and Functions
-----------------------------------------------------------------------10
9、Abnormity Diagnose
-------- ---------------------------------------------------------------13
10、System Flow Chart
-----------------------------------------------------------------------14
11、Circuit Diagram
----------------------------------------------------------------------------15
12、Maintenance Service and Trouble Shooting 13、Wiring Diagram
-----------------------------------16
--------------------------------------------------------------------------18
14、Exploded View and Parts Lists
-----------------------------------------------------19
1
Domestic Air Conditioner
Model: HWR10XC6
Product Code Illumination And Series Introduction 1.Model identification: H W A B
C
D
E
F
G
A: Abbreviation of Haier B: Abbreviation of Window C: R-Remote Control F-Mechanical Control D: Nominal cooling capacity(BTU/h) with the first two numbers based on one thousand unit E: The type of power supply X: 115V/60HZ V:208/220V/50HZ F: Function code C-Cooling only H-Heating pump E-Electric aided heating G: Design code E SA A
B
C
D
A: Abbreviation of Energy Star B: No meaning C: Nominal cooling capacity(BTU/h) with the first two numbers based on one thousand unit D: Design code Examples: HWR10XC6 It represents remote contrl window air conditioner.Cooling capacity is 10000BTU/h and the power supply is 115V /60Hz.
2.Standard situation/conditions No.
Operating condition
Indoor air state
outdoor air state
D.B.℃
W.B.℃
D.B.℃
W.B.℃
1
Nominal cooling
26.7
19.4
35
23.9
2
Nominal heating
/
/
/
/
3
Nominal electrical heating
/
/
/
/
2
Domestic Air Conditioner
Specifications: Item
UNIT
HWR10XC6
Cooling capacity
BTU/h
10000
Heating capacity
BTU/h
/
Power supply Cooling
1PH/115V/60Hz Power input
W
1020
Running current
A
9.0
BTU/(hW)
9.8
Power input
W
/
Running current
A
/
BTU/(hW)
/
Indoor side
dB(A)
Outdoor side
dB(A)
Type
56/54/52 / 347 500 450 445 570 494 64 68.5 Rotate
Model
44R261AG-AJS
EER Heating
COP Sound Level
Case
Packaging dimensions Weight
Compressor
Height
mm
Width
mm
Depth
mm
Height
mm
Width
mm
Depth
mm
Net
lbs
Gross
lbs
Running cap. for comp.
µF
60uf/250VAC
Starting method Pressure
Heating side
Psig
380
Cooling side
Psig
170
Model
Refrigerant
Charge Type
Fan
PSC
Fan speed
outdoorunit indoor unit
r/min
outdoorunit
r/min
Moisture removal Exchanging pipe type/ diameter
0.49
kg
indoor unit
Air volume
Fin material
R22
CFM Pints/hr mm
Acentric fan Axial fan 1300±30/1200±40/1100 ±30 / 235 3.0 Evaporator:ф7 condenser:ф7 Hydrophile aluminum foil
3
Model: HWR10XC6
Domestic Air Conditioner
Safety and Precaution
4
Model: HWR10XC6
Domestic Air Conditioner
Warning and Cautions
5
Model: HWR10XC6
Domestic Air Conditioner
Model: HWR10XC6
347
Net Dimention
500
450
6
Domestic Air Conditioner
Installation and Accessory Parts
7
Model: HWR10XC6
Domestic Air Conditioner
Model: HWR10XC6
Installation and Accessory Parts
O N/ O FF
MO DE
SPEE D
TI ME R
TEM P/ TIM E
Remote control
Model: HWR10XC6
8
“ CR2025“ battery
Domestic Air Conditioner
Installation and Accessory Parts
HWR08XC5,HWR10XC6 ESA3065, ESA3085
HWR08XC5, ESA3065, ESA3085 HWR10XC6
13 16 1 20 4 5 8
9
Model: HWR10XC6
Domestic Air Conditioner
Installation and Accessory Parts
10
Model: HWR10XC6
Domestic Air Conditioner
Installation and Accessory Parts
11
Model: HWR10XC6
Domestic Air Conditioner
Parts and Functions
12
Model: HWR10XC6
Domestic Air Conditioner
Model: HWR10XC6
Abnormity Diagnose 1. Sensor diagnose: 2 seconds after the sensors open circuit or short circuit, the unit will turn off automatically and the LED will show E0 until the sensors resume. 2. Keystroke circuit error diagnose: When power on for the first time, the PCB will check the keystroke circuit, if the sampling value is different with the theory value, the LED will show E1, which means failed keystroke circuit. The keyboard is locked and so invalid, but the remote control is working normally.
13
Domestic Air Conditioner
Model: HWR10XC6
System Flow Chart Indoor heat exchanger
Outdoor heat exchanger
Compressor
Capacillary tube Cooling
14
Domestic Air Conditioner
注:1、R7为模式选择, 挂高为四模式, 不挂高为两模式。 2、R8为风速档数选择, 挂高为三挡, 不挂高为两挡。 3、R14,R15为华氏/摄氏选择, 挂高为摄氏, 接地为华氏。
弱板
强板
Circuit Diagram
Model: HWR10XC6
R212K R222K
+5V
R302K DQ2 9012
+5
DQ1 9012
DQ4 9012
DQ3 9012
R312K C9
CN3
5
10
R15 10k 100UF/16V 104 C10
R9 C15
4M
C30 102 ×¢£ºÁ¬Ðø11¸ö102
VSS P37 XIN P36 XOUT P35 TEST P34 VDD P33(AIN1) P21(XTIN) P32(AIN0) P22(XTOUT) P31 /RESET P30 P20P12(/DVO) P00(TXD) P11(INT1) P01(RXD) P10(/INT0) P02(SCLK)P07 P03(MOSI)P06 P04(MISO) P05(/SS)
28 27 26 25 24 23 22 21 20 19 18 17 16 15
C17 102
L3
L4
L5
L6
L7
L8
L9
L10
L1
GFABCEDH
R23 R24 R25 R26 R27 R28 R29
330 330 330 330 330 330 330
+5V
+5
C20 C22 100U/16V 104
PB1 +12 R11
R18560
1K
K3
K4
K5
K6
K7 R38 10K E D O M
R16 Q1 2.2K 9012
K2
D E E P S
A1 Q1 A2 Q2 A3 Q3 A4 Q4 A5 Q5 A6 Q6 A7 Q7 GND VCC
K1
R E M I T T H G I L - V + U E M I T / P - M E E T M I T / P M F E F T O / N O R E W O P
R10 2K
IC22003 1 2 3 4 +5 5 R84.7k R12 22k 6 7 8 R74.7K R13 22k
L2
1 4 3 9 8 7 6 2
IC1TMP86C807 1 2 3 4 5 6 7 8 9 10 11 12 13 14
CX1
L1
LED1
N A F
10K
102
L R O E O V C A S Y G R E N E M U H E D W O L
R14
CN20 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
D E M
1K C5 C6 100UF/16V 104
H G F I F H O R E M N I O T R E T M H I G T F I F L O - / V N U O R E W O P
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
16 15 14 13 12 11 10 9
R19 2.2K
C11R17 104 10K
R42
R41
1K
1K
R32
1K +5V R39
R33
R34
R35
R36
R37
2K
2K
2K
3K
10K
330 REV
C16104
VCC GND OUT
3 2 1
R40 C21 10K 4.7UF/50V
+12 +5
+5 JK3
JK2
JK1
JK4 R20 10K
C7 R43 4.7UF/50V C8 5.1K R410K R310K 4.7UF/50V
D1
1 3
R5
N
+5 5.1K
D3
5.1K +5
S2 S3 S4 S5
C3
CN1
C4
C1
470UF16V
1 2
2 1
2 1
LOW MID HIGH
CN4 盘管温度
ZR1
D4 4
104
COMPRESSORUV
Vout Vin
1
104104 R6 2
FUSE1
S1 2 TRANS 1
RG1 7805
+5 C13C12
L
D2
CN2
室温
L1
15
104
C2 1000UF/25V
3
C14 0.1u/250V
Domestic Air Conditioner
Model: HWR10XC6
Maintenance Service and Trouble Shooting
Always unplug your air conditioner before cleaning. The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary. To remove: 1. Open the inlet grille downward by pulling out the top of the inlet grille. 2. Remove the air filter from the front grille assembly by pulling the air filter up slightly. o o 3. Clean the filter with warm, soapy water below 40 C(104 F). 4. Rinse and gently shake the water from the filter and let it dry before replacing it. DO NOT use your air conditioner without the air filter in place. To clean the front panels or the cabinet DO NOT use harsh chemicals, abrasives, ammonia, chlorine, bleach, concentrated detergents, solvents or metal scouring pads. Some of these chemicals
16
Domestic Air Conditioner
Model: HWR10XC6
Maintenance Service and Trouble Shooting Trouble Shooting If air conditioner does not operate: Check if unit is plugged in.The plug may have come loose. ●Check if the unit is in “off” mode. ●The fan control may be in “off” position. ●
Air from air conditioner is warm: The A/C setting may need to be raised. ●The temperature outside the room is below 65°F。The conpressor will not cycle on if the temperature outside is below 65°F.
●
Ice formation on cooling coils: Outside temperature too cold .Set the unit on fan only setting to defrose ice. ●Lower temperature setting.Temperature setting may be too cold. ●Unit BTU may be too high for the room. ●
17
Domestic Air Conditioner
Model: HWR10XC6
Wiring Diagram 0010556721
WIRING DIAGRAM R: RED W: WHITE B: BLACK G: GREEN GR: GRAY BL: BLUE OR: ORANGE YL: YELLOW
SIGNAL RECEIVER BOARD
IC1
POWER SUPPLY CN20 SENSOR
Y/G: YELLOW/GREEN
B(NO RIBBED) CN2
W(RIBBED)
G
CN3 COM CN4
UV LIGHT
NO
JK4-1
PROTECTOR
B FUSE1 FUSE (250V 3.15A)
TRANSFORMER
C
COMPRESSOR
M
TR
CN5 HI MED LOW
S
R R
N
W C
HERM
CAPACITOR FAN
GR R OR B
3
6
5
BL
W
1
4
GR
BL R OR YL
FAN MOTOR
NOTE:THE COMPONENT PART IN BROKEN LINE AREA ISN'T AVAILABLE FOR THE UNIT WITHOUT UV-LIGHT FUNCTION.
M BL
Y/G
18
2
Domestic Air Conditioner
Model: HWR10XC6
Sincere Forever
Haier Group Haier Industrial Park, No.1, Haier Road 266101, Qingdao, China http://www.haier.com
21