LOGO! logic module LOGO! modular SIPLUS LOGO! modular pure variants
■ Overview • Basic variants optimized for costs • Interface for the connection of expansion modules, up to 24 digital inputs, 16 digital outputs, 8 analog inputs and 2 analog outputs can be addressed • With connection option for LOGO! text display TD (can be connected to all LOGO! 0BA6 basic versions) Note: SIPLUS extreme products are based on Siemens Industry standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added.
■ Technical specifications Article number
6AG1052-2CC01-2BA6
6AG1052-2MD00-2BA6
6AG1052-2HB00-2BA6
6AG1052-2FB00-2BA6
Based on
6ED1052-2CC01-0BA6
6ED1052-2MD00-0BA6
6ED1052-2HB00-0BA6
6ED1052-2FB00-0BA6
SIPLUS LOGO! 24CO
SIPLUS LOGO! 12/24RCO
SIPLUS LOGO! 24RCO
SIPLUS LOGO! 230RCO
• Min.
-40 °C; = Tmin
-40 °C; = Tmin
-40 °C; = Tmin
-40 °C; = Tmin
• max.
70 °C; = Tmax; 55 °C @ UL/cUL use
70 °C; = Tmax; 55 °C @ UL/cUL use
70 °C; = Tmax; 55 °C @ UL/cUL use
70 °C; = Tmax; 55 °C @ UL/cUL use
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)
100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions)
100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions)
100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions)
100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions)
- against biologically active substances / conformity with EN 60721-3-3
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
- against chemically active substances / conformity with EN 60721-3-3
Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation!
- against mechanically active substances / conformity with EN 60721-3-3
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
Ambient conditions Ambient temperature in operation
Extended ambient conditions • Relative to ambient temperatureatmospheric pressure-installation altitude
Relative humidity - With condensation, max.
Resistance
Siemens ST 70 · 2015
2/15
2
© Siemens AG 2015
LOGO! logic module LOGO! modular SIPLUS LOGO! modular pure variants
■ Ordering data
2
Article No.
Article No.
SIPLUS LOGO! 24o
Accessories
24 V DC supply voltage, 8 digital inputs 24 V DC, of which 4 can be used in analog mode (0 to 10 V), 4 digital outputs 24 V DC, 0.3 A, integrated time switch; without display and keyboard; 200 function blocks can be interlinked, modular expansion capability
SIPLUS Upmiter upstream device
Extended temperature range and exposure to media
Further accessories
6AG1052-2CC01-2BA6
SIPLUS LOGO! 230RCo 115/230 V AC/DC supply voltage, 8 digital inputs 115/230 V AC/DC, 4 relay outputs 10 A, integral time switch; without display and keyboard; 200 function blocks can be interlinked, modular expansion capability Extended temperature range and exposure to media
6AG1052-2FB00-2BA6
SIPLUS LOGO! 24RCo 24 V AC/DC supply voltage, 8 digital inputs 24 V AC/DC, 4 relay outputs 10 A, integral time switch; without display and keyboard; 200 function blocks can be interlinked, modular expansion capability Extended temperature range and exposure to media
6AG1052-2HB00-2BA6
SIPLUS LOGO! 12/24RCo 12/24 V DC supply voltage, 8 digital inputs 12/24 V DC, of which 4 can be used in analog mode (0 to 10 V), 4 relay outputs 10 A, integral time switch; without display and keyboard; 200 function blocks can be interlinked, modular expansion capability Extended temperature range and exposure to media
2/16
Siemens ST 70 · 2015
6AG1053-1AA00-2AA0
for reliable operation at the battery of combustion engines
6AG1052-2MD00-2BA6
See LOGO! modular pure variants, page 2/14