EMC Symmetrix VMAX Cloud Edition array is the first enterprise class storage ...
EMC VMAX, the simplicity of a self-service portal, RESTful APIs, and the ...
EMC SYMMETRIX VMAX CLOUD EDITION STARTER KITS EMC Symmetrix VMAX Cloud Edition array is the first enterprise class storage service delivery platform that provides multi-tenant, automated delivery of levels of service, with the ease of self-service access.
Specifications VMAX FOR AS-A-SERVICE DELIVERY EMC VMAX Cloud Edition array is engineered for service providers and end customers delivering enterprise class cloud their way. The VMAX Cloud Edition array lowers operational costs and streamlines the delivery of world-class storage services through the convenience of a self-service catalog and linearized pricing. VMAX Cloud Edition array excels at quickly and cost-effectively delivering enterprise class storage services to power your as-a-service delivery. It combines the power of EMC VMAX, the simplicity of a self-service portal, RESTful APIs, and the intelligence of automated provisioning to shrink operational costs and provide tenants with a broad range of choice in world-class storage services. Trusted multi-tenancy and built-in chargeback reporting streamline operations and accelerate delivery of world-class storage services.
VMAX Cloud Edition
ARCHITECTURE SPECIFICATIONS The VMAX Cloud Edition array combines the EMC Symmetrix VMAX with a multitenant self-service portal and pre-engineered service level definitions. Storage is provided to create as-a-service delivery from the self-service portal by selecting from a catalog of pre-engineered service bands for policy based, automated storage delivery. VMAX Cloud Edition array provides integrated tenant reporting on usage, utilization, service levels, and trends available from customizable standardized reports or accessed via REST APIs. Each VMAX Cloud Edition array ships with a Automation Appliance containing two servers configured as a high availability cluster. Connectivity from the appliance to the EMC Symmetrix VMAX is via 8Gb/s Fibre Channel HBA. Connectivity to the EMC Datacenter is via VPN (virtual private network). VMAX Cloud Edition array also requires a call home line to EMC's Secure Remote Support Gateway. ESRS Gateway uses FIPS 140-2 validated cryptography. Communications utilize Advanced Encryption Standard (AES)-256 algorithm and use an RSA digital certificate key exchange.
SPECIFICATION SHEET
SELF-SERVICE PORTAL SPECIFICATIONS To support a self-service portal, EMC operates two datacenters, one primary and one secondary. If the primary data center experiences issues or becomes unavailable, connectivity is directed to the secondary data center to continue operation. The selfservice portal provides easy access via VPN to provision and manage the preengineered storage bands from the storage services catalog.
DATA AT REST (D@RE) ENCRYPTION VMAX Cloud Edition array offers Data at Rest Encryption with no impact on performance. Data is encrypted when written to drives and decrypted when read. VMAX Cloud Edition array's D@RE addresses security and compliance concerns regarding data exposure when drives are removed or replaced.
REPRESENTATIONAL STATE TRANSFER (REST) API VMAX Cloud Edition array offers RESTful APIs to enable Service Providers to programmatically integrate VMAX Cloud Edition capabilities directly into their own existing orchestration infrastructure. The APIs exposed are multi-tenant aware providing access to provisioning, data protection, billing, metering, and reporting data using either JSON or XML formatting. A dedicated machine at the customer site connects using HTTPS to the EMC API Server using an EMC issued certificate.
SERVICE CATALOG SPECIFICATIONS The service catalog is created from pre-engineered service level definitions and configurations that establish how the VMAX Cloud Edition is purchased and how services are provided and consumed by clients. A configuration may consist of multiple packs on a given service level and multiple service levels in the full solution of up to 10 VMAX Cloud Edition arrays or up to 10PB usable.
HARDWARE COMPONENTS: Total power and environmental requirements are determined through summation of the Automation Appliance and the VMAX Cloud Edition arrays (up to 10) included. Below are the specs for each.
Cloud Edition Automation Appliance The Automation Appliance consists of two 1U servers that are mountable in a standard 19" rack (rack not included). This allows for up to 5 PB to be managed by the Appliance.
Ethernet Connectivity The VMAX Cloud Edition solution requires the following Ethernet connectivity: •
4 1Gb/s ports for the dual-server Automation Appliance
•
1 1Gb/s port on VMAX for ESRS
•
7 IP Addresses within the same VLAN for the Appliance and 1 IP address for the VMAX Cloud Edition array's ESRS port.
•
VPN connectivity from Ethernet switch
Fibre Channel Ports in the Customer SAN Both the Automation Appliance and each VMAX Cloud Edition array require connectivity via 8Gb/s FC ports in the customer's SAN: •
16 to 64 (require all ports on all engines be connected) 8Gb/s FC ports for management and data paths for each VMAX Cloud Edition array
•
4 8Gb/s FC ports for the Automation Appliance
VMAX Cloud Edition Arrays Each VMAX Cloud Edition array consists of service level packs selected. Since the service level packs can vary, listed below are the values for a fully configured VMAX Cloud Edition array. Valid configurations will use no more power and cooling than what is listed. Up to 10 VMAX Cloud Edition arrays can be configured per Management Appliance. Your actual power and cooling requirements per array will be less than these specifications unless your VMAX Cloud Edition array is fully configured.
SERVICE CATALOG SPECIFICATIONS SERVICE
PERFORMANCE
PROVISIONED
LEVEL
TYPE
USE CASE
FC PORTS
DIAMOND
Ultra High
HPC, latency sensitive
8
PLATINUM
Very High
Mission critical, high rate OLTP
8
Write heavy I/O, GOLD
High
Database logs, data
8
sets
SILVER
BRONZE
Price/Perf.
Cost optimized
Database data sets, virtual applications
Backup, Archive, File
4
2
1
SERVICE
IOPS/GB 2
BAND
CAPACITY TBU
Diamond
3.87
1.7
Plat-3
2.96
2.7
Plat-2
1.71
13.8
Plat-1
1.38
13.5
Gold-4
1.07
14.8
Gold-3
1.04
26.7
Gold-2
0.85
25.9
Gold-1
0.68
13.0
Silver-4
0.48
25.3
Silver-3
0.38
50.6
Silver-2
0.35
13.2
Silver-1
0.26
12.1
Bronze-2
0.16
11.1
Bronze-1
0.04
10.1
1
Number represents the number of ports assigned to the service level band. Internally, each VMAX engine has 16 front end ports. The ports assigned to a given service level band may and typically do overlap with other service level bands deployed on the same VMAX engine.
2
IOPS/GB range has been determined using a 50-50 combination of OLTP with 8KB IO request size and DSS workloads with 64KB IO request size. It further takes into account resource limitations of the Service Level pack selected, i.e. VMAX engine(s) and disk drives. These values are common-use targets and not guarantees of realized performance. The workload presented by your mix of applications will likely vary from the tested workload resulting in somewhat different IOPS/GB.
Capacity Optimized Small Starter Kit: 46.6TBu Capacity This starter kit begins with two packs of Silver-2 plus two packs of Bronze-1 from the Service Catalog. This totals 46.6 TB of usable capacity. Growth from a Starter Kit can be up to 10 VMAX Cloud Edition arrays managed by the included Automation Appliance.
CAPACITY AND PERFORMANCE SPECIFICATIONS
SL Band Silver-2 Bronze-1
Quantity Capacity/unit 2 13.2TB 2 10.1TB
Capacity 26.4TB 20.2TB
IOPS/GB/unit 0.35 0.04
IOPS 9,616 839
PHYSICAL SPECIFICATIONS Height: 75" / 190.5 cm Width: 24" / 61.0 cm Depth: 42" / 106.7 cm Weight: 1315 lb / 596.5 kg
POWER CONSUMPTION AND COOLING VMAX Cloud Edition Starter Kit 1 total
2.64KvA
8.2KBTU/hr.
Max VMAX Cloud Edition System Bay
4.0KvA
12.8KBTU/hr.
Max VMAX Cloud Edition Storage Bay
3.9KvA
12.3KBTU/hr.
Cooling for both bays is front to rear
POWER AND ENVIRONMENTAL SPECIFICATIONS
SPECIFICATION
NORTH AMERICAN
INTL. 3 WIRE
3 WIRE Nominal voltage
200-240 VAC +/- 10% L-L
200-240 VAC +/- 10%
Nom
L-L Nom
Frequency
50-60 Hz
50-60 Hz
Circuit breakers
30 A
32 A
Power zones
Two
Two
Customer site (minimum)
Two 30 A, Single-phase
Two 32 A, Single-phase
drops per bay
drops per bay
L=line or phase; N=neutral; G=ground The table above describes electrical specifications for systems installed in North America, International, and Australian sites.
ENVIRONMENTAL
RANGE
Temperature extreme (F / C)
50-90 / 10-32
Altitude (ft / m) Max
7,500 / 2,286
Humidity, non-condensing
20% - 80%
Raised Floor
Recommended
Capacity Optimized Medium Starter Kit: 100TB Capacity This starter kit begins with six packs of Silver-2 plus three packs of Bronze-1 from the Service Catalog. This totals 109.5 TB of usable capacity. Growth from a Starter Kit can be up to 10 VMAX Cloud Edition arrays managed by the included Automation Appliance.
CAPACITY AND PERFORMANCE SPECIFICATIONS
SL Band Silver-2 Bronze-1
Quantity Capacity/unit 6 13.2TB 3 10.1TB
Capacity 79.2TB 30.3TB
IOPS/GB/unit IOPS 0.35 28,856 0.04 1,259
PHYSICAL SPECIFICATIONS Height: 75" / 190.5 cm Width: 24" / 61.0 cm Depth: 42" / 106.7 cm Weight: 2246 lb / 1018.8 kg
POWER CONSUMPTION AND COOLING VMAX Cloud Edition Starter Kit 2 total
5.39KvA
17.0KBTU/hr.
System Bay 1
3.62KvA
11.4KBTU/hr.
Storage Bay 1A
1.77KvA
5.6KBTU/hr.
Max VMAX Cloud Edition Engine Bay
4.0KvA
12.8KBTU/hr.
Max VMAX Cloud Edition Storage Bay
3.9KvA
12.3KBTU/hr.
Cooling for both bays is front to rear
POWER AND ENVIRONMENTAL SPECIFICATIONS
SPECIFICATION
NORTH AMERICAN
INTL. 3 WIRE
3 WIRE Nominal voltage
200-240 VAC +/- 10% L-L
200-240 VAC +/- 10%
Nom
L-L Nom
Frequency
50-60 Hz
50-60 Hz
Circuit breakers
30 A
32 A
Power zones
Two
Two
Customer site (minimum)
Two 30 A, Single-phase
Two 32 A, Single-phase
drops per bay
drops per bay
L=line or phase; N=neutral; G=ground The table above describes electrical specifications for systems installed in North America, International, and Australian sites.
ENVIRONMENTAL
RANGE
Temperature extreme (F / C)
50-90 / 10-32
Altitude (ft / m) Max
7,500 / 2,286
Humidity, non-condensing
20% - 80%
Raised Floor
Recommended
Capacity Optimized Large Starter Kit: 200TB Capacity This starter kit begins with twelve packs of Silver-2 plus six packs of Bronze-1 from the Service Catalog. This totals 205.8 TB of usable capacity. Growth from a Starter Kit can be up to 10 VMAX Cloud Edition arrays managed by the included Automation Appliance.
CAPACITY AND PERFORMANCE SPECIFICATIONS
SL Band Silver-2 Bronze-1
Quantity Capacity/unit 11 13.2TB 6 10.1TB
Capacity 145.2TB 60.6TB
IOPS/GB/unit IOPS 0.35 52,891 0.04 2,519
PHYSICAL SPECIFICATIONS Height: 75" / 190.5 cm Width: 24" / 61.0 cm Depth: 42" / 106.7 cm Weight: 3952 lb / 1792.6 kg
POWER CONSUMPTION AND COOLING VMAX Cloud Edition Starter Kit 3 total
10.0KvA
31.8KBTU/hr.
System Bay 1
3.74KvA
11.8KBTU/hr.
System Bay 2
3.85KvA
12.2KBTU/hr.
Storage Bay 1A
2.46KvA
7.8KBTU/hr.
Max VMAX Cloud Edition Engine Bay
4.0KvA
12.8KBTU/hr.
Max VMAX Cloud Edition Storage Bay
3.9KvA
12.3KBTU/hr.
Cooling for both bays is front to rear
POWER AND ENVIRONMENTAL SPECIFICATIONS
SPECIFICATION
NORTH AMERICAN
INTL. 3 WIRE
3 WIRE Nominal voltage
200-240 VAC +/- 10% L-L
200-240 VAC +/- 10%
Nom
L-L Nom
Frequency
50-60 Hz
50-60 Hz
Circuit breakers
30 A
32 A
Power zones
Two
Two
Customer site (minimum)
Two 30 A, Single-phase
Two 32 A, Single-phase
drops per bay
drops per bay
L=line or phase; N=neutral; G=ground The table above describes electrical specifications for systems installed in North America, International, and Australian sites.
ENVIRONMENTAL
RANGE
Temperature extreme (F / C)
50-90 / 10-32
Altitude (ft / m) Max
7,500 / 2,286
Humidity, non-condensing
20% - 80%
Raised Floor
Recommended
Performance Optimized Small Starter Kit: 50TB This starter kit begins with one pack of Gold-1, two packs of Silver-2, plus one pack of Bronze-2 from the Service Catalog. This totals 51 TB of usable capacity. Growth from a Starter Kit can be up to 10 VMAX Cloud Edition arrays managed by the included Management Appliance.
CAPACITY AND PERFORMANCE SPECIFICATIONS
SL Band Gold-1 Silver-2 Bronze-2
Quantity Capacity/unit 1 13.0TB 2 13.2TB 1 11.1TB
Capacity IOPS/GB/unit 13.0 TB 0.68 26.4TB 0.35 11.1TB 0.16
IOPS 9,183 9,616 1,883
PHYSICAL SPECIFICATIONS Height: 75" / 190.5 cm Width: 24" / 61.0 cm Depth: 42" / 106.7 cm Weight: 1870 lbs. / 848.2 kg.
POWER CONSUMPTION AND COOLING VMAX Cloud Edition Starter Kit 4 total
3.56KvA
10.9KBTU/hr.
System Bay 1
3.07KvA
9.4KBTU/hr.
Storage Bay 1A
0.49KvA
1.5KBTU/hr.
Max VMAX Cloud Edition System Bay
4.0KvA
12.8KBTU/hr.
Max VMAX Cloud Edition Storage Bay
3.9KvA
12.3KBTU/hr.
Cooling for both bays is front to rear
POWER AND ENVIRONMENTAL SPECIFICATIONS
SPECIFICATION
NORTH AMERICAN
INTL. 3 WIRE
3 WIRE Nominal voltage
200-240 VAC +/- 10% L-L
200-240 VAC +/- 10%
Nom
L-L Nom
Frequency
50-60 Hz
50-60 Hz
Circuit breakers
30 A
32 A
Power zones
Two
Two
Customer site (minimum)
Two 30 A, Single-phase
Two 32 A, Single-phase
drops per bay
drops per bay
L=line or phase; N=neutral; G=ground The table above describes electrical specifications for systems installed in North America, International, and Australian sites.
ENVIRONMENTAL
RANGE
Temperature extreme (F / C)
50-90 / 10-32
Altitude (ft / m) Max
7,500 / 2,286
Humidity, non-condensing
20% - 80%
Raised Floor
Recommended
Performance Optimized Medium Starter Kit: 100TB This starter kit begins with four packs of Gold-1, two packs of Silver-2, plus two packs of Bronze-2 from the Service Catalog. This totals 100.6 TB of usable capacity. Growth from a Starter Kit can be up to 10 VMAX Cloud Edition arrays managed by the included Automation Appliance.
CAPACITY AND PERFORMANCE SPECIFICATIONS
SL Band Gold-1 Silver-2 Bronze-2
Quantity Capacity/unit 4 13.0TB 2 13.2TB 2 11.1TB
Capacity IOPS/GB/unit IOPS 52.0TB 0.68 36,733 26.4TB 0.35 9,616 22.2TB 0.16 3,765
PHYSICAL SPECIFICATIONS Height: 75" / 190.5 cm Width: 24" / 61.0 cm Depth: 42" / 106.7 cm Weight: 2786 lb / 1263.7 kg
POWER CONSUMPTION AND COOLING VMAX Cloud Edition Starter Kit 5 total
6.30KvA
19.9KBTU/hr.
System Bay 1
3.10KvA
9.8KBTU/hr.
System Bay 2
3.20KvA
10.1KBTU/hr.
Max VMAX Cloud Edition System Bay
4.0KvA
12.8KBTU/hr.
Max VMAX Cloud Edition Storage Bay
3.9KvA
12.3KBTU/hr.
Cooling for both bays is front to rear
POWER AND ENVIRONMENTAL SPECIFICATIONS
SPECIFICATION
NORTH AMERICAN
INTL. 3 WIRE
3 WIRE Nominal voltage
200-240 VAC +/- 10% L-L
200-240 VAC +/- 10%
Nom
L-L Nom
Frequency
50-60 Hz
50-60 Hz
Circuit breakers
30 A
32 A
Power zones
Two
Two
Customer site (minimum)
Two 30 A, Single-phase
Two 32 A, Single-phase
drops per bay
drops per bay
L=line or phase; N=neutral; G=ground The table above describes electrical specifications for systems installed in North America, International, and Australian sites.
ENVIRONMENTAL
RANGE
Temperature extreme (F / C)
50-90 / 10-32
Altitude (ft / m) Max
7,500 / 2,286
Humidity, non-condensing
20% - 80%
Raised Floor
Recommended
Performance Optimized Large Starter Kit: 200TB This starter kit begins with eight packs of Gold-1, four packs of Silver-2, plus four packs of Bronze-2 from the Service Catalog. This totals 204 TB of usable capacity. Growth from a Starter Kit can be up to 10 VMAX Cloud Edition arrays managed by the included Management Appliance.
CAPACITY AND PERFORMANCE SPECIFICATIONS
SL Band Gold-1 Silver-2 Bronze-2
Quantity Capacity/unit 8 13.0TB 4 13.2TB 4 11.1TB
Capacity IOPS/GB/unit IOPS 104.0TB 0.68 73,466 52.8TB 0.35 19,233 44.4TB 0.16 7,530
PHYSICAL SPECIFICATIONS Height: 75" / 190.5 cm Width: 24" / 61.0 cm Depth: 42" / 106.7 cm Weight: 4964 lbs. / 2251.6 kg
POWER CONSUMPTION AND COOLING VMAX Cloud Edition Starter Kit 6 total
11.59KvA
36.6KBTU/hr.
System Bay 1
3.66KvA
11.6KBTU/hr.
System Bay 2
3.77KvA
11.9KBTU/hr.
System Bay 3
2.96KvA
9.3KBTU/hr.
Storage Bay 1A
1.20KvA
3.8KBTU/hr.
Max VMAX Cloud Edition System Bay
4.0KvA
12.8KBTU/hr.
Max VMAX Cloud Edition Storage Bay
3.9KvA
12.3KBTU/hr.
Cooling for both bays is front to rear
POWER AND ENVIRONMENTAL SPECIFICATIONS
SPECIFICATION
NORTH AMERICAN
INTL. 3 WIRE
3 WIRE Nominal voltage
200-240 VAC +/- 10% L-L
200-240 VAC +/- 10%
Nom
L-L Nom
Frequency
50-60 Hz
50-60 Hz
Circuit breakers
30 A
32 A
Power zones
Two
Two
Customer site (minimum)
Two 30 A, Single-phase
Two 32 A, Single-phase
drops per bay
drops per bay
L=line or phase; N=neutral; G=ground The table above describes electrical specifications for systems installed in North America, International, and Australian sites.
ENVIRONMENTAL
RANGE
Temperature extreme (F / C)
50-90 / 10-32
Altitude (ft / m) Max
7,500 / 2,286
Humidity, non-condensing
20% - 80%
Raised Floor
Recommended
AUTOMATION APPLIANCE PHYSICAL SPECIFICATIONS Height: 1.7” inches (43.2 mm) Width: 17.25” inches (438.0 mm) Depth: 27.928” inches (709.37 mm) Weight: 40 lbs (18.1Kg) Maximum
MAX POWER CONSUMPTION AND COOLING VMAX Cloud Edition Automation Appliance
750 W
2560 BTU/hr.
Cooling is front to rear
POWER AND ENVIRONMENTAL SPECIFICATIONS
SPECIFICATION Nominal voltage
90 – 264 VAC, auto-ranging,
Frequency
47 Hz - 63 Hz
ENVIRONMENTAL
RANGE
Operating temperature extreme
50-95 / 10-35
(F / C) Non-operating temperature
-40-149 / -40-65
extreme (F / C) Operating altitude (ft / m) max
10,000/ 3,048 (for altitudes above 2950 feet, the maximum operating temperature is de-rated 1°F/550 ft.)
Operating humidity, non-
20% - 80% (recommended operating range 40%
condensing
55%)
Maximum vibration
5Hz to 500Hz .21g RMS random
Operating maximum shock
Half sine,3g ,11mSec
VMAX CLOUD EDITION ARRAY Up to 10 VMAX Cloud Edition arrays can be managed by one Automation Appliance (pair of servers shown above). Starter Kits use one of these 10 possible arrays. The specifications below are for individual add-on arrays at maximum configuration. Each VMAX Cloud Edition array specified at full configuration
PHYSICAL SPECIFICATIONS Height: 75" / 190.5 cm Width: 24" / 61.0 cm Depth: 42" / 106.7 cm Weight: 1550 lb / 703 kg
MAX POWER CONSUMPTION AND COOLING VMAX Cloud Edition System Bay
4.0KvA 12.8KBTU/hr.
VMAX Cloud Edition Storage Bay
3.9KvA 12.3KBTU/hr.
Cooling for both bays is front to rear
POWER AND ENVIRONMENTAL SPECIFICATIONS
SPECIFICATION
NORTH AMERICAN
INTL. 3 WIRE
3 WIRE Nominal voltage
200-240 VAC +/- 10% L-L
200-240 VAC +/- 10%
Nom
L-L Nom
Frequency
50-60 Hz
50-60 Hz
Circuit breakers
30 A
32 A
Power zones
Two
Two
Customer site (minimum)
Two 30 A, Single-phase
Two 32 A, Single-phase
drops per bay
drops per bay
L=line or phase; N=neutral; G=ground The table above describes electrical specifications for systems installed in North America, International, and Australian sites.
ENVIRONMENTAL
RANGE
Temperature extreme (F / C)
50-90 / 10-32
Altitude (ft / m) Max
7,500 / 2,286
Humidity, non-condensing
20% - 80%
Raised Floor
Recommended
CONTACT US To learn more about how EMC products, services, and solutions can help solve your business and IT challenges, contact your local representative or authorized reseller— or visit us at www.EMC.com. EMC2, EMC, the EMC logo, Symmetrix, TimeFinder, VMAX, and VMAX Cloud Edition are registered trademarks or trademarks of EMC Corporation in the United States and other countries. All other trademarks herein are the property of their respective owners. © Copyright 2012, 2013 EMC Corporation. All rights reserved. Published in the USA. 9/13 Specification Sheet H11713.1
www.EMC.com
EMC believes the information in this document is accurate as of its publication date. The information is subject to change without notice.