Current Developments in Nutrition
CDN/2016/000257
DOI: 10.3945/cdn.116.000257 1
Tricaprylin alone increases plasma ketone response more than coconut oil or other medium chain triglycerides: an acute crossover study in healthy adults Camille Vandenberghe1, 2, Valérie St-Pierre1, 2, Tyler Pierotti3, Mélanie Fortier1, Christian-Alexandre Castellano1, Stephen C Cunnane1, 2,4 1
Research Center on Aging, Sherbrooke, QC, Canada (CV, VSP, MF, CAC, SCC)
Departments of 2Pharmacology and Physiology, and 4Medicine, Université de Sherbrooke, Sherbrooke, QC, Canada (CV, VSP, SCC) 3
Department of Biology-Health Sciences, Bishop’s University, Sherbrooke, QC, Canada
(TP)
Author for correspondence: Stephen Cunnane Research Center on Aging, 1036 Belvedere St. South, Sherbrooke, QC, Canada J1H 4C4 Tel: 1 819 780-2220, ext 45670;
[email protected]
Abbreviations: AcAc, acetoacetate; β-HB, β-hydroxybutyrate; FFA, free fatty acids; CO, coconut oil; MCT, medium chain triglyceride; C8, tricaprylin; C10, tricaprin; AD, Alzheimer’s disease.
Financial support: MCT were provided by Abitec Corporation, Columbus, USA. Financial support from NSERC and Sojecci 2. Trial Registration: NCT 02679222 on ClinicalTrials.gov. Conflict of interest: The authors declare that they have no conflicts interest.
Current Developments in Nutrition
CDN/2016/000257
DOI: 10.3945/cdn.116.000257 2
1
ABSTRACT
2
Background: Ketones are the brain’s main alternative fuel to glucose. Dietary medium chain
3
triglyceride (MCT) supplements increase plasma ketones but their ketogenic efficacy relative to
4
coconut oil (CO) is not clear. Objective: To compare the acute ketogenic effect in healthy adults
5
of the following test oils: coconut oil (CO; 3% C8, 5% C10), classical MCT oil (C8/C10; 55%
6
C8, 35% C10), tricaprylin (>95% C8), tricaprin (>95% C10), or CO mixed 50:50 with C8/C10 or
7
C8. Design: In a crossover design, 7 men and 2 women of 34±12 y took two 20 mL doses of the
8
test oils prepared as an emulsion in 250 mL of lactose-free skim milk. During the control test
9
(CTL), participants received only the milk vehicle. The first test dose was taken with breakfast
10
and the second at noon but without lunch. Blood was sampled every 30 min over 8 h for plasma
11
acetoacetate and β-hydroxybutyrate analysis. Results: C8 was the most ketogenic test oil with a
12
day-long mean of +295±155 µmol/L above CTL. C8 alone induced the highest plasma ketones
13
expressed as the areas-under-the-curve (AUC) for 0-4 h and 4-8 h; 780±426 µmol h/L and
14
1876±772 µmol h/L, respectively; these values were 813% and 870%, respectively, more than
15
CTL (P6.1 mmol/L and glycosylated
60
hemoglobin >6.0%), strenuous aerobic exercise more than three times a week, CO allergy,
61
untreated hypertension, dyslipidemia, abnormal renal, liver, heart or thyroid function. This
62
project is registered on ClinicalTrials.gov (NCT 02679222).
63
64
65
Test Oils The composition of the CO (President’s Choice®, Toronto, ON, CAN) is shown in Table
66
1. The MCT oil was 55% C8, 35% C10 (Captex 355, Abitec, Columbus, OH, USA). The C8 oil
67
was 95% pure tricaprylin (Captex 8000, Abitec, Columbus, OH, USA). The C10 oil was 95%
68
pure tricaprin (Captex 1000, Abitec, Columbus, OH, USA). A 20 mL dose of each test oil was
69
mixed with 250 mL of lactose-free skim milk (Natrel®, Longueuil, QC, CAN) using a blender
70
(Magic Bullet©, Los Angeles, CA, USA). CO and C10 are solid at room temperature so they were
71
melted in a water bath at 60°C prior to blending into the milk base.
72
Current Developments in Nutrition
CDN/2016/000257
DOI: 10.3945/cdn.116.000257 6
73
74
Experimental design The protocol involved seven separate but identical metabolic study days for each
75
participant, hence a repeated/longitudinal measurements design during which the test substances
76
were evaluated in random order: vehicle (CTL; 250 mL lactose-free skim milk) or 20 mL of the
77
test oils mixed with 250 mL of lactose-free skim milk (CO; C10; C8; C8/C10; CO + C8/C10
78
[50:50]; CO + C8 [50:50]) taken twice, once at breakfast and once at mid-day. Participants were
79
single blinded and crossed over from one treatment to the next during the trial course. The test
80
sequence was determined a priori by the investigator, and the participants were randomized to
81
sequences. On each metabolic study day, the participants arrived at 7:30 a.m. after a 12 h
82
overnight fast and a minimum of 24 h without alcohol intake. A forearm venous catheter was
83
installed and a baseline blood sample (Time 0) withdrawn. Participants then received a standard
84
breakfast during which they consumed the test beverage. The breakfast consisted of two pieces of
85
toast with raspberry jam, a piece of cheese, and two scrambled eggs. A second dose of the test
86
beverage was given alone for lunch, i.e. with no other food (Table 1). Water was available ad
87
libitum throughout the study day. Blood samples were taken as baseline (pre-dose) and every 30
88
min during 8 h with the first post-dose sample being taken 30 min after the test beverage was
89
consumed. Blood samples were centrifuged at 2846 g for 10 min at 4°C and plasma stored at -
90
80°C until analyzed.
91
92
93
Plasma metabolites analyses Plasma β-HB and AcAc were measured by an automated colorimetric assay as previously
94
described (9). Briefly, for AcAc, 25 μL of plasma was mixed with 330 μL of fresh reagent (Tris
95
buffer, pH 7.0, 100 mmol/L, 20 mmol/L sodium oxamate; 0.15 mmol/L NADH and 1U/mL β-
Current Developments in Nutrition
CDN/2016/000257
DOI: 10.3945/cdn.116.000257 7
96
hydroxybutyrate dehydrogenase [β-HBDH]). For β-HB, the reagent was Tris buffer (pH 9.0; 20
97
mM sodium oxamate, 1 mmol/L NAD, and 1U/mL β-HBDH). Tris, oxamic acid, DL-β-HB
98
sodium salt, Li-AcAc standard, and NAD were purchased from Sigma (St. Louis, MO, USA),
99
NADH, from Roche (Mannheim, Germany), and β-HBDH from Toyobo (Osaka, Japan). The
100
change in absorbance at 340 nm between 15 and 120 s after the addition of the reagent was
101
measured on an automated clinical chemistry analyzer (Dimension Xpand Plus; Siemens,
102
Deerfield, IL, USA). The assay was calibrated with freshly diluted standards from frozen aliquots
103
of a 10 mmol/L standard of Li-AcAc or DL-β-HB sodium salt, which is stable at -20°C for 2 and
104
6 months, respectively. Calibrations and quality controls were performed for each assay to ensure
105
the precision of the kits (coefficient of variation between tests 5 ± 1 %). Plasma glucose, lactate,
106
triglycerides, cholesterol, (Siemens Medical Solutions USA, Inc., Deerfield, IL, USA) and FFA
107
(Randox Laboratories Limited, West Virginia, USA) were analysed using commercial kits.
108
Glycated hemoglobin was measured by HPLC-723G7, a fully automated high performance liquid
109
chromatography instrument-reagent system (Tosoh Bioscience, King of Prussia, PA, USA).
110
111
112
Statistical analysis All results are given as the mean ± SEM. The sample size calculation was based on a
113
previous study in which 8 participants were sufficient to measure a significant difference (β=
114
0.80) in plasma ketones after consuming 30 g of MCT oil (9) . We had n=9 for the present study
115
in case of a dropout during one of the seven tests. All statistical analyses were carried out using
116
SPSS 23.0 software (SPSS Inc., Chicago, IL, USA). Plasma ketone data are all reported in
117
relation to Time 0 (baseline). When plasma ketones are given in the plural, this refers to the total
118
of AcAc and β-HB combined. The second test dose was given 4 h after the first so the half-day
Current Developments in Nutrition
CDN/2016/000257
DOI: 10.3945/cdn.116.000257 8
119
periods are reported as 0-4 h and 4-8 h. For total ketones, the areas-under-the-curve (AUC) from
120
0-4 h and 4-8 h were calculated according the trapezoid method (11). Since the data were not
121
normally distributed (N