STQC ‐ IT Services STQC Directorate, Department of Information Technology, Ministry of Communications & Information Technology, Electronics Niketan, 6 CGO Complex, Lodi Road, New Delhi – 110003
(Issue 1 Dated November 2011)
Page 1 of 6
SINGLE FINGER PRINT SCANNER FOR AUTHENTICATION
(Issue 1 Dated November 2011)
Page 2 of 6
Parameters Minimum Platen Area
Resolution
Specification
12.8 mm (w) x 16.5 mm (h)
Basis for Certification Supplier to submit test report along with application STQC Lab – visual inspection and dimension measurement.
Supplier to submit test report along Minimum 500 DPI with 5% with application margin on the lower side
Grey scale/ Image 8 bit, 256 levels type
STQC Lab ‐ functional testing with test harness Supplier to submit test report along with application STQC Lab ‐ functional testing
ISO 19794‐2 for fingerprint Supplier to submit test report for minutiae template syntactical conformance (provisional) Extractor & Image and Template Standard STQC Lab ‐ functional testing with test ISO 19794‐4 for Fingerprint harness (certificate of approval) Image Template Image Quality: Sensor: Must be listed on "IAFIS Certified Product List" posted on Image Quality Test Procedure: https://www.fbibiospecs.o Certificate of conformance by supplier rg/IAFIS/Default.aspx under "PIV Single Finger (Provisional) Capture Devices” Image quality and OR Lab Test conformance Extractor Quality report showing compliance to ISO 19794‐4 Annexure A, Extractor: Test harness to check for compliance of the extracted template. OR any other equivalent conformance report( to be approved for equivalence by expert committee appointed by Competent authority)
(Certificate of approval)
Parameters
Specification
Basis for Certification
Extractor: Number of Minutiae generated by extractor to be in conformance to ISO Specification. Tested for at least 12 Minutiae points generated under test conditions. Test Report asserting under Certificate stating the assertion along 2% FRR for sample size of with test report (templates to be 1500 Residents using test published) and/ or technical rationale Performance Test servers holding aadhaar (provisional) (Detailed guidelines to be Testing for operational evaluation. (Certificate of approval) published) Statement of conformity by supplier
NFIQ Quality Software
Inbuilt NFIQ quality software either at device level or extractor level.
Maximum Acquisition time (Placement to Template)
Audio/Visual indication
= 8Kv
Test report by supplier / certification from competent authority (provisional) Testing by STQC for certificate of approval.
Environment, ROHS certification health and safety
Safety
EMC compliance
UL or IEC60950 compliance
FCC class A or equivalent
Declaration by vendor Certificate / test report (provisional) Testing by STQC for certificate of approval. Certificate / test report (provisional) Testing by STQC for certificate of
Parameters
Specification
Basis for Certification approval. STQC will test functionality on two OS – Windows & Linux using test harness
For other OS, vendor’s declaration that the same certified sensor & extractor Operating system Vendor needs to declare the version will work on other applicable environment compatible operating OS system (provisional)
Testing by STQC for certificate of approval.
Connectivity
Declaration by vendor and supported 1. Standard USB connectivity for PC by test report / certificate based application. (provisional) 2. Connectivity for POS Testing by STQC for certificate of approval. devices.
Note: These specifications are subject to change based on field findings.