View - Imo

23 downloads 222 Views 3MB Size Report
IMO is at the forefront of control component technology specifically developed ... with IP67 protection, UL-94-5VA fire resistance and provide class 2 protection.
Solar Installer Range

Bright solutions

IMO is at the forefront of control component technology specifically developed for the renewable energy market and in particular solar energy. Whether meeting the demands of safe and efficient DC switching or delivering solutions that help to maximise solar energy conversion rates, you can be sure that IMO products have been developed to meet the highest technical and commercial standards. Our carefully selected range of Solar products have been brought together, to provide today’s solar installer with the products they require to keep Solar safe on all their installations.

Specifically developed for arduous DC disconnect applications, the IMO range of Solar Isolators features an operator independent trigger ratchet switching mechanism resulting in switching times of less than 5ms. High reliability knife edge contacts and long arc cooling chambers ensure safe and effective isolation of DC voltages within solar installations.

IMO’s range of mobile connectors are used to connect PV panels in series. They also link between lengths of cabling and allow connection to Branch and Panel connectors. Branch connectors are used to link multiple strings together allowing, for example, a 2 pole (single string) DC isolator to switch both strings at the same time removing the need to use 2 isolators. Panel connectors mount on solar string boxes, enclosed DC isolators and any other enclosed DC switching device allowing easy connection to the rest of the PV system.

Available in 2 to 8 pole versions in a wide variety of mounting and handle configurations, the IMO Solar Isolator range is suitable for most OEM or site installation applications.

IMO’s range of enclosed IP65 rated AC isolators includes 3 to 8 pole versions rated from from 20A to 80A. The design also includes an interlocked enclosure lid and 3 padlockable positions for safety.

Safety! The IMO SI is a True DC switch not an AC version de-rated or re-wired for DC operation. Features include: Operator independent switching mechanism High speed trigger ratchet switching (5ms max) IP65 rated enclosure with top and bottom M25/M20/M16/M12 push outs and rear cable entry Fully enclosed internal switch without additional wiring for maximum safety Knife edge contacts and arc cooling chambers High reliability rotary snap action mechanism Maximum 1Nm torque for easy operation Compact space saving design 16mm2 box terminals for easy wiring

WARNING

The IMO SI range has a switching speed that is independent of the operator. The mechanism is such that there is no direct linkage between the operator handle and the switch contacts. As the handle is moved it interacts with a spring mechanism which, upon reaching a set point, causes all the contacts to “SNAP” over thereby ensuring a very fast break/make action which means that the arcs produced by the constant DC load are normally extinguished within 5ms. Many alternative solutions, particularly those based upon AC isolator design, have a switching speed that is directly linked to operator speed. Slow operation of the handle results in slow separation of the contacts and can produce arcing times of 100ms or more. The SI range also features a “knife edge” mechanism so that when the unit is operated there is a double break on each pole with arcing effect occuring on the corners of the switch only. The main contact is made on an area where no arcing has occurred. The rotary nature of the contact mechanism also means that when the SI is operated a self-cleaning action occurs on the arcing points, thereby producing good contact integrity over the life of the product. A secondary advantage of this type of operation in photovoltaic applications is that, in the event of a supply to earth failure, the short circuit current pulls the contacts together thereby giving an extremely high short circuit current capability in the order of up to 1700A (product dependant). Completing the package for all your PV instalation requirements is the IMO range of Solar Connectors. Rated up to 1000V 30A for 2.5-6mm2 cables, the IMO connectors feature a secure easy clip and release system providing the installer with a time saving and efficient connector solution. As with all IMO PV products the connectors have been tested to the highest standards and come rated with IP67 protection, UL-94-5VA fire resistance and provide class 2 protection.

3

Mobile connectors are used to connect PV panels in series. They also link lengths of cabling and allow connection to Branch and Panel connectors. Branch connectors are used to link multiple strings together allowing, for example, a 2 pole (single string) DC isolator to switch both strings at the same time. Panel connectors mount on solar string boxes, enclosed DC isolators and any other enclosed DC switching device allowing easy connection to the rest of the PV system.

1000V DC 30A Rated For 4-6mm² Cables Secure Easy Clip and Release System IP67 Protection UL94-5VA Fire Protection Class 2 Protection

4

Part Number

Description

Pack Quantity

SIC-M-4M SIC-M-4F SIC-P-4M SIC-P-4F SIC-B-4PAIR SIC-I-4M SIC-I-4F

Male mobile connector Female mobile connector Male panel connector Female panel connector 1xMFF + 1xFMM branch connectors Male connector metal insert (spare) Female connector metal insert (spare)

100 100 100 100 1 Pair 100 100

The IMO SI Solar Switch range has been specifically developed as a “True DC” to disconnect the DC/AC inverter from the photovoltaic panels as illustrated. All photovoltaic installations have to be equipped with DC isolators in accordance with IEC 60364-7-712.

Photovoltaic Module

DC-switch disconnector (IMO SI..)

Available in 2, 4, 6 and 8 pole versions Operator independent trigger ratchet switching mechanism for high

DC/AC Inverter

speed switching (5ms max) Knife edge self cleaning contact mechanism

AC-switch disconnector (IMO PE, LB, PM, & DM..)

Long arc cooling chambers Maximum torque 1Nm for easy operation G83/1 Compliant We recommend installers label equipment: “Danger - Contains live parts during daytime”. Rotary Actuator Version

Emergency Stop Rotary Actuator Version

..PEL64R..

..ES-PEL..

Type

2-pole

2-pole 4 Paralleled poles

4-pole

2-pole with Input on top Output bottom

2-pole with Input and Output bottom

2-pole with Input and Output on top

SI16 SI25 SI32

2 2 2

2H 2H 2H

4 4 4

4S 4S 4S

4T 4T 4T

4B 4B 4B

Contacts Wiring diagram

Switching example

5

Rotary Actuator Switch Lockable Off Plastic Enclosure IP65 NEMA Type 1 DC21B Rating

6

600V 12A 16A 20A 25A 32A

700V 12A 16A 20A 23A 27A

800V 10A 16A 18A 20A 23A

900V 9A 13A 14A 16A 20A

1000V 6A 9A 10A 11A 13A

1200V 4A 6A 7A 8A 10A

1500V 1A 3A 4A 4A 5A

29A 45A 50A

16A 23A 27A

16A 20A 23A

13A 16A 20A

9A 11A 13A

6A 8A 10A

12A 16A 20A 25A 32A

12A 16A 20A 23A 27A

10A 16A 18A 20A 23A

9A 13A 14A 16A 20A

6A 9A 10A

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 25A 32A

Poles Number Weight in series of Strings kg/pcs.

Part Number

2 2 2 2 2

1 1 1 1 1

0.43 0.43 0.43 0.43 0.43

SI12 PEL64R 2 SI16 PEL64R 2 SI20 PEL64R 2 SI25 PEL64R 2 SI32 PEL64R 2

3A 4A 5A

2 2 2

1 1 1

0.49 0.49 0.49

SI16 PEL64R 2H SI25 PEL64R 2H SI32 PEL64R 2H

1A 3A 4A 4A 5A

2 2

2 2

11A 13A

4A 6A 7A 8A 10A

2 2

2 2

0.46 0.46 0.46 0.46 0.46

SI12 PEL64R 4 SI16 PEL64R 4 SI20 PEL64R 4 SI25 PEL64R 4 SI32 PEL64R 4

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 20A 23A

4 4 4

1 1 1

0.47 0.47 0.47

SI16 PEL64R 4S SI25 PEL64R 4S SI32 PEL64R 4S

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 20A 23A

4 4 4

1 1 1

0.47 0.47 0.47

SI16 PEL64R 4T SI25 PEL64R 4T SI32 PEL64R 4T

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 20A 23A

4 4 4

1 1 1

0.47 0.47 0.47

SI16 PEL64R 4B SI25 PEL64R 4B SI32 PEL64R 4B

Contact Configuration

Emergency Stop Lever Actuator Switch Lockable Off Plastic Enclosure IP65 NEMA Type 1 DC21B Rating 600V 12A 16A 20A 25A 32A

700V 12A 16A 20A 23A 27A

800V 10A 16A 18A 20A 23A

900V 9A 13A 14A 16A 20A

1000V 6A 9A 10A 11A 13A

1200V 4A 6A 7A 8A 10A

1500V 1A 3A 4A 4A 5A

29A 45A 50A

16A 23A 27A

16A 20A 23A

13A 16A 20A

9A 11A 13A

6A 8A 10A

12A 16A 20A 25A 32A

12A 16A 20A 23A 27A

10A 16A 18A 20A 23A

9A 13A 14A 16A 20A

6A 9A 10A 11A 13A

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 25A 32A

Poles Number Weight in series of Strings kg/pcs.

Part Number

2 2 2 2 2

1 1 1 1 1

0.39 0.39 0.39 0.39 0.39

SI12 ES-PEL 2 SI16 ES-PEL 2 SI16 ES-PEL 2 SI25 ES-PEL 2 SI32 ES-PEL 2

3A 4A 5A

2 2 2

1 1 1

0.45 0.45 0.45

SI16 ES-PEL 2H SI25 ES-PEL 2H SI32 ES-PEL 2H

4A 6A 7A 8A 10A

1A 3A 4A 4A 5A

2 2 2 2 2

2 2 2 2 2

0.42 0.42 0.42 0.42 0.42

SI12 ES-PEL 4 SI16 ES-PEL 4 SI20 ES-PEL 4 SI25 ES-PEL 4 SI32 ES-PEL 4

16A 25A 32A

16A 25A 32A

16A 20A 23A

4 4 4

1 1 1

0.43 0.43 0.43

SI16 ES-PEL 4S SI25 ES-PEL 4S SI32 ES-PEL 4S

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 20A 23A

4 4 4

1 1 1

0.43 0.43 0.43

SI16 ES-PEL 4T SI25 ES-PEL 4T SI32 ES-PEL 4T

16A 25A 32A

16A 25A 32A

16A 25A 32A

16A 20A 23A

4 4 4

1 1 1

0.43 0.43 0.43

SI16 ES-PEL 4B SI25 ES-PEL 4B SI32 ES-PEL 4B

Contact Configuration

7

Main Contacts Rated thermal current Ithe Rated insulation voltage Ui 1) Rated insulation voltage Ui 2) Contact distance (per pole) Rated operational current Ie DC21B 1 pole L/R+1ms 1

2 pole in series 1

2

2 poles in series +2 poles parallel 1

2

3

4

3 poles in series 1

2

3

4 poles in series

1

2

3

4

Rated operational current Ie DC22B 1 pole L/R+2.5ms 1

2 poles in series 1

2

3 poles in series 1

2

3

4 poles in series 1

2

3

4

Unit

SI12

SI16

SI20

SI25

SI32

A V V mm

12 1000 1500V 8

16 1000 1500V 8

20 1000 1500V 8

25 1000 1500V 8

32 1000 1500V 8

500V 600V 800V 1000V 500V 600V 700V 800V 900V 1000V 1200V 1500V 500V 600V 700V 800V 900V 1000V 1200V 1500V 500V 1000V 1200V 1500V 500V 600V 700V 800V 900V 1000V 1200V 1500V

A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A

6 4 2 1 12 12 12 10 9 6 12 12 12 12 12 12 12 12 -

9 6 3 1.5 16 16 16 16 13 9 6 3 29 29 16 16 13 9 6 3 16 16 12 9 16 16 16 16 16 16 16 16

10 7 3.5 1.75 20 20 20 18 14 10 20 20 20 20 20 20 20 20 -

11 8 4 2 25 25 23 20 16 11 8 4 45 45 23 20 16 11 8 4 25 25 14 11 25 25 25 25 25 25 25 20

13 10 5 2.5 32 32 27 23 20 13 10 5 58 50 27 23 20 13 10 5 32 32 16 13 32 32 32 32 32 32 32 23

500V 600V 800V 1000V 500V 600V 800V 1000V 500V 600V 800V 1000V 500V 600V 800V 1000V

A A A A A A A A A A A A A A A A

0.75 0.3 0.25 0.5 5 4 1 0.5 12 12 5 4.5 12 12 8 6

1 0.5 0.3 0.15 7 5.5 2 1 16 16 6.5 5.5 16 16 11.5 8

1.5 0.6 0.35 0.15 7.5 5.75 2.25 1.25 20 20 6.75 5.75 20 20 11.75 8.5

1.25 0.75 0.4 0.2 8 6 2.5 1.5 25 23 7 6 25 25 12 9

1.5 1 0.5 0.25 9 6.5 3 2 27 25 7.5 6.5 32 27.5 12.5 10

1) Suitable at 1000V for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp=8kV 2) Suitable at 1000V for: earthed-neutral systems, overvoltage category I to III, polution degree 2 (min. IP55): Uimp = 8kV. Data for other conditions on request.

8

Main Contacts

Unit

SI12

SI16

SI20

SI25

SI32

Rated condistional short-circuit current Max. fuse size gL (gG) Mechanical life Rated short-time withstand current (1s) ICW 2,4 / 2H Short circuit making capacity ICW 2,4 / 2H Maximum cable cross sections (inc. jumper SIV-B1) Solid or standard flexible flexible (+multicore cable end) Sise of terminal screw Tightening torque Maximum ambient temperature Operation Open Enclosed Storage Power loss per switch at Ie max. DC21B 2 2 + 2H 4

kAeff A x103 A A

5 32

5 40

5 50

5 63

5 80 10 1000 / 1700 1000 / 1700

Main Contacts

Unit

SI12

SI16

SI20

SI25

SI32

350V 500V 600V 350V 500V 600V 350V 500V 600V

A A A A A A A A A

3.5 3.5 3.5 12 12 12 24 24 12

4 4 4 16 16 16 29 29 21

4.5 4.5 4.5 18 18 18 38 36 22

5 5 5 20 20 20 45 38 23

6 6 6 25 25 25 58 40 25

350V 500V 600V 4 poles in series 350V 1 2 3 4 500V 600V Industrial Control Switch

A A A A A A

12 12 12

16 16 16 16 16 16

20 20 20

25 25 25 25 25 25

32 32 32 32 32 32

A

32

40

50

60

80

AWG AWG AWG lb.inch

12 - 10 12 - 6 12 - 6 M4 Pz2 11 - 16

12 - 10 12 - 6 12 - 6 M4 Pz2 11 - 16

12 - 10 12 - 6 12 - 6 M4 Pz2 11 - 16

12 - 10 12 - 6 12 - 6 M4 Pz2 11 - 16

12 - 10 12 - 6 12 - 6 M4 Pz2 11 - 16

A A

12 -

16 29

20 -

25 45

32 58

Ampere-Rating “General use” (AC) 1 pole 1

2 poles in series 1

2

2 poles in series + 2 poles parallel 1

2

3

4

3 poles in series 1

2

3

Fuse size (RK5) 5kA / 600V Maximum cable cross sections (incl. jumper SIV-B1) Solid or stranded Flexible Flexible (+ multicore cable end) Size of terminal screw Tightening torque Rated operational current Ie AC21B A2, A4 A2+2

Ue max. 440V Ue max. 440V

10 800 / 1300 800 / 1300

10 900 / 1500 900 / 1500

mm2 mm2 mm2

4 - 16 4 - 10 4 - 10 M4 Pz2 1.2 - 1.8

Nm o

C C o C

-40 to +65 -40 to +45 -50 +90

o

W W W

2 3.5 4

5 8.5 10

8 14 16

SI12PEL/ES-PEL SI16PEL/ES-PEL SI20PEL/ES-PEL SI25PEL/ES-PEL SI32PEL/ES-PEL

9

3 and 4 Pole (6-8 Pole avaliable on request) On load 20A - 80A Red/Yellow Handle 3 Padlock Positions IP65

PE..

(e.g. PE69-3020)

Rated insulation voltage Rated thermal current Ratings @ 415V AC21 AC22 AC23 Making capacity @ 415V Breaking capacity @415V Electrical Life @ rated load Mechanical Life Maximum cable size Weight

Switch Rating 20A to 40A 63A and 80A

10

A

B

130 200

98 120

D1

Unit

69-3020 69-4020

69-3025 69-4025

69-3032 69-4032

69-3040 69-4040

69-3063 69-4063

69-3080 69-4080

Ui Ith

690V 20A

690V 25A

690V 32A

690V 40A

690V 63A

690V 80A

A A Kw Aeff Aeff

20 20 5.5 120 110

25 25 7.5 150 135

32 32 11 220 200

40 40 15 300 250

63 63 18.5 370 330

80 80 22 44 380

x103 mm2 g

100 10 0.46

100 10 0.46

100 10 0.46

100 10 0.46

100 25 0.46

100 25 0.46

E

2xM20/25 75 M40.5/ 95 32.5 + 16.5

F

H

100 165

77 86

Data according to IEC 947-5-1, VDE 0660, EN 60947-3, EN 60947-5-1 Main contacts

Type PE69..20 PE69..25 PE69..32 PE69..40 PE69..63 PE69..80

Rated thermal Ith open Rated thermal current Ithe enclosed Rated insulation voltage Ui1) Rated operational current Ie AC21A Making capacity Ieff Breaking capacity

3x380-440V 3x220-240V 3x380-440V 3x660-690V Disconnection properly performed up to Motor Switch AC3 3x400V Motor Switch AC3 3x220-240V Direct switching single motors 3x380-440V 3x660-690V Main Switch AC23 3x400V Motor Switch AC23A 3x220-240V Main Switch AC23B 3x380-440V Safety Switch 3x660-690V Rated conditional short-circuit current Max. fuse size gL (gG) Mechanical life Rated short-time withstand current (1sec. current) Maximum cable cross sections Solid Flexible (+multicore cable end) Size of terminal screw Tightening torque Auxillary contacts Rated insulation voltage Ui1) Rated thermal current Ith , Ithe Switching capacity AC15 220-240V AC15 380-440V Rated conditional short-circuit current Max. short circuit protection gL (gG) Maximum cable cross sections Solid Flexible (+ multicore cable end)

A A V A A A A A V A kW kW kW A kW kW kW kAeff A x103 A

20 20 690 20 160 160 160 80 690 12 3 5.5 5.5 16 4 7.5 5.5 10 25 200 250

25 25 690 25 190 180 180 110 690 16 4 7.5 7.5 20 5.5 10 7.5 10 35 200 300

32 32 690 32 220 200 200 140 690 23 5.5 11 11 25 7.5 12.5 11 10 40 200 400

40 40 690 40 300 250 250 170 690 30 7.5 15 15 32 9 16 15 10 50 200 500

63 63 690 63 370 330 330 190 690 37 11 18.5 18.5 45 15 22 18.5 10 63 100 600

80 80 690 80 440 380 380 220 690 37 11 18.5 18.5 45 15 22 18.5 10 80 100 850

mm2 AWG mm2 AWG Nm Ib.inch

10 8 6 10 M3.5 0.8-1.7 7-15

10 8 6 10 M3.5 0.8-1.7 7-15

10 8 6 10 M3.5 0.8-1.7 7-15

10 8 6 10 M3.5 0.8-1.7 7-15

25 4 16 6 M5 2-4 18-35

25 4 16 6 M5 2-4 18-35

V A A A kAeff A

690 10 2.5 1.5 3 10

690 10 2.5 1.5 3 10

690 10 2.5 1.5 3 10

690 10 2.5 1.5 3 10

690 10 2.5 1.5 3 10

690 10 2.5 1.5 3 10

mm2 AWG mm2 AWG

2.5 12 2.5 14

2.5 12 2.5 14

2.5 12 2.5 14

2.5 12 2.5 14

2.5 12 2.5 14

2.5 12 2.5 14

V A HP HP HP HP HP HP HP A A

600 20 1 3 7.5 10 1 1 2 40 40

600 25 1.5 5 10 10 1 2 2 50 50

600 32 2 5 10 15 1 2 3 50 50

600 40 2 5 10 15 1 2 3 70 50

600 63 3 10 20 25 2 3 5 90 70

600 80 5 10 20 25 2 3 5 110 70

Data according to UL and cUL

Rated voltage Ampere-Rating “General use” DOL-Rating 3-Phase

DOL-Rating 1-Phase

Fuse size (RK5) 5kA / 600V

110-120V 220-240V 440-480V 550-600V 110-120V 200-208V 220-240V Manual Motor Controller Motor Disconnect

1) Suitable for: earthed-neutral systems, overvoltage categoryI to III, pollution degree 3 (standard-industry): Uimp=6kV. Data for other conditions on request 2) The values after the slash are valid for switches 6-pole or more 3) Suitable for no oad apploications (AC20A) above 690V 4) Fuse RK1/10kA/600V 5) Uimp=8kV

11

IMO Worldwide Offices IMO Precision Controls Limited 1000 North Circular Road Staples Corner London NW2 7JP United Kingdom

IMO Jeambrun Automation SAS Centre D’Affaires Rocroy 30, Rue de Rocroy 94100 Saint-Maur-Des-Fosses France

IMO Automazione Via Ponte alle Mosse, 61 50144 Firenze (FI) Italia

Tel: 020 8452 6444 Fax: 020 8450 2274 Email: [email protected] Web: www.imopc.com

Tel: 0800 912 712 (toll free) Fax: 0145 134 737 Email: [email protected] Web: www.imojeambrun.fr

Tel: 800 930 872 (toll free) Fax: 8000 452 6445 Email: [email protected] Web: www.imopc.it

IMO Canada Unit 32 - B - North 18 Stratheam Avenue, Brampton Ontario L6T 4Y2 Canada

IMO UK IMO Russia IMO Jeambrun IMO Automazione

Tel: 905 799 9237 (local) Fax: 905 799 0450 Email: [email protected] Web: www.imopc.com

IMO Canada IMO South Africa IMO Pacific

IMO Russia Office No 4063 9, Zemlyanoy Val, 105064 Moscow Russia

IMO South Africa (Pty) Ltd G16 Centurion Business Park Montague Gardens Cape Town 7441 South Africa

IMO Pacific Pty Ltd 1/34 Fallon Road Landsdale Perth WA 6065 Australia

Tel: 8 800 100 8540 (toll free) Fax: 8 800 100 8541 Email: [email protected] Web: www.imopc.com

Tel: 021 551 1787 Fax: 021 555 0676 Email: [email protected] Web: www.imopc.co.za

Tel: 08 9302 5246 (local) Fax: 08 9303 9908 Email: [email protected] Web: www.imopacific.com.au

ISO 9001 Registered

CAT-Solar/Installer/2011

Quality Management

015