Biorid Spine QA Stiffness Test Initial Trial - UNECE
Recommend Documents
.6 (2.5). 88. TABLE III. AND TOPSET INF unit: mm ckset. BioRID. 53. 51. N/A. N/A. 53. 54. 55. 53.2 (1. S seated ..... S6 vs BioRID. Average NRM. (b. S1 vs BioRID.
the application of both initial stiffness and secant stiffness based DBD .... ensure that the design strength, yield displacement and required initial stiffness values ...
ABSTRACT. Response of initial elastic field to stiffness perturbation and its possible application is investigated. Virtual thermal softening is used to produce the ...
May 14, 2013 - Nanomechanics and Nanotribology Laboratory, Department of Mechanical and Materials Engineering,. Florida International ..... SE ¼ ase 2vE Ð 1 Ñ. Ю. Pmax hmax .... Fellowship (DYF) from the University Graduate School,.
Test de evaluare iniŃială – Disciplina Matematică. Clasa a IV-a. Pagina 1 din 2.
TEST DE EVALUARE INIłIALĂ. Anul şcolar 2011-2012. Disciplina Matematică.
Test de evaluare iniŃială – Disciplina Matematică. Clasa a II-a. Pagina 1 din 3.
TEST DE EVALUARE INIłIALĂ. Anul şcolar 2011-2012. Disciplina Matematică.
Page 1 of 2. QA ANALYST EXAMINATION RECORD. Item: QA Analyst Test. Description. QA Analyst testing record. Version : 01.
T9. T10. Whoops! There was a problem loading this page. QA Analyst test record.pdf. QA Analyst test record.pdf. Open. Ex
Sep 24, 2002 - "relative visual attenuation quotient" means the relative visual quotient (Q) and is defined in annex 13.
Jan 6, 2012 - in a random order, and their passive axial spine rotation was measured. .... between axial rotational stiffness and age, weight, height, or.
bending model using an electromagnetic tracking device and a force platform; lumbar flexion and extension ROM was measured using an electromagnetic ...
Dec 12, 1998 - pared with more distal intervertebraljoints, the rib cage, muscles, skin ...... 9 Viner A, Lee hl, Adams R. Posteroanterior stiffness in the lumbosa-.
evaluate spinal joint stiffness.11,40 This involves the identification of a specific vertebral level, to ... relationship between stiffness and neck pain has not yet been ...
University of Vermont. Abstract. This study presents initial field-test evaluation feedback on training materials designed to help prepare paraeducators to assist in ...
On orbit transfer of cryogenic liquids is considered enabling to many future. NASA missions ... as the planning stages of the Apollo Program (ref. 2). One of the .... Second, it has a ... Two 0-1 psi delta pressure transducers provide pressure drop.
pmr-trial-2011-science-qa-penang.pdf. pmr-trial-2011-science-qa-penang.pdf. Open. Extract. Open with. Sign In. Main menu
Sep 14, 2012 - Fifty-five such studies were identified. Forty-six of the ... cant poorer 7-year relapse-free survival (RFS; 72% vs. 84% with ..... transfer [26], and RT delivery within a prospective trial, is kept rea- .... (supplement to ICRU report
Sep 14, 2012 - a Geneva University Hospital, Switzerland; b CHU Charleroi; c EORTC HQ, ..... cal trials. More specifically, the large variation in definitions of.
May 14, 2013 - The experimental load-displacement curve obtained by probing ... modulus of a material and b is the correction factor that ... developed by Oliver and Pharr.2 To evaluate the slope, one ... shown that the total and elastic energy const
Ambient Air Density Variation. ➢ Density variation is within 7.5 % as allowed by
ECE and Indian Regulation upto temperature of 44 deg C. Reference.
Bent spine syndrome (BSS) is defined as an unusual con- dition characterized by .... locates in flavin adenine dinucleotide (FAD) domain, and p.307Ser>Cys ...
▻Simple test setup. ▻Using adapters to existing equipment ... ▻Read initial
position of C4, T1, T8, and L1 using inclinometer from stand or tilt sensors ...
Page 8 ...
Biorid Spine QA Stiffness Test Initial Trial
Paul Depinet Mar. 20, 2012
Goals ►Measure quasi-static spine stiffnesses – With and without torsion pins – Flexion and Extension directions
►Do not damage spine ►Simple test setup ►Using adapters to existing equipment
Extension with Pins ►Setup pull pulley as far back as possible
Extension with Pins ►Mount spine to stand as shown ►Adjust manual EOT limit to 100 N through menus – A max pull force of 100 N gives max lumbar loads of ~60 Nm for extension
►Put the torso stand into Manual Mode
Extension with Pins ►Shake spine to center it ►Read initial position of C4, T1, T8, and L1 using inclinometer from stand or tilt sensors ►See photos for bracket screw positions
T8 & L1 locations
C4 location T1 location
Extension with Pins ►Pull to 100 N and hold while measuring all locations
Flexion with Pins ►Mount spine to stand as shown ►Adjust manual EOT limit to 100 N through menus – A max pull force of 100 N gives max lumbar loads of ~50 Nm for flexion
►Put the torso stand into Manual Mode NOTE: picture is setup without screws which removes pins from system
Flexion with Pins ►Shake spine to center it ►Read initial position of C4, T1, T8, and L1 using inclinometer from stand or tilt sensors ►See photos for bracket screw positions
T8 & L1 locations
C4 location T1 location
Flexion with Pins ►Pull to 100 N and hold while measuring all locations
Tests WITHOUT Pins ►To remove the effect of pins, remove all screws from the washer plates so that all vertabrae move freely – see “flexion with pins” setup photo on page 7
►Repeat measurement process for – Flexion – Extension
Results Dummies 0007 and 0077 ►Flexion Test with adjusted spines 20
0 C4
T1
T8
L1
Pelvis
-20 Initial #77
Initial angles
@ 100N #77 Initial #77NB
-40
@ 100N #77NB Initial # 7 @ 100N # 7
-60
@ 100N -80
-100
Possible Test Improvements ►Use 4 sensors to simultaneously measure all locations ►Do continuous data collection ►Measure rebound ►Measure lumbar My loads ►Try decreasing pull angle