WLTP: Proposal for C/D test temperature range - UNECE
Recommend Documents
Dec 9, 2011 ... characteristics of which are given in Table 1. ... Bearing strength according to ISO
2439B (N) ... Compression resistance EN ISO 3386/1. (40%.
Oct 30, 2013 - MiCoCe as a data host for projects: The MiCoCe services can also only be used for a restricted time period, for example the runtime of a ...
Oct 30, 2013 - Remote Access (RA), respectively on Remote Desktop solutions, defined as ... any kind of terminal or desktop solution that uses a secured connection to the servers .... software applications that will be needed by researchers.
an SL-200e and an SL-400e under these conditions against their closest ...
TracKing is compatible with all Thermo King dataloggers and trailer controllers.
Sep 24, 2002 - "relative visual attenuation quotient" means the relative visual quotient (Q) and is defined in annex 13.
22/12/2012 STRICTLY PRIVATE CONFIDENTIAL PCMSummary 2013-1 PlusICE PCM TEMPERATURE (H) RANGE 2013-1 PCM Phase Change Temperature Density Latent Heat Capacity ...
Apr 3, 2014 - On M1 and N1 vehicles less than 6 m in length, with an arrangement complying with paragraph 6.5.5.2. above
(71st GRE, 31 March-3 April 2014, agenda item 4(c)). Proposal to amend UN regulation No. 48 concerning the activation of
Jan 23, 2018 - D. NOTAM INFO: NAV GPS (NTTR GPS 18-01) (INCLUDING WAAS, GBAS, AND. ADS-B) MAY NOT BE AVBL WI A 496NM RAD
Nov 30, 2004 - Materials (ASTM) are identified for the testing activities. .... The ASME normally adopts the ASTM specification of a material with little or ...... E 139-00 ...... Corrosion Behaviour in the Stress Free and the Stressed Stateâ, Werk
Email: [email protected] ...... price. The stand volume may be reported in cubic metres over bark but the purchaser may need to convert.
Keywords: Tracking PV, Field Monitoring, Performance Test Conditions, .... Modelling of conditions for accelerated lifetime testing of humidity impact on ...
SeX sex diet. CD. 183. CD. 129. CD sex drug diet poly(IC) CD poly(IC) CD .... uninjected uninjected uninjected weight 8wk weight glucose ketones. 154. 0.6.
Dec 21, 2015 - SÃntesis de ensayos de lixiviación mediante stalles en el yacimiento Sierra Pintada, CNEA internal report, unpublished. [26] Coffey Mining Pty ...
2Laboratório de Máquinas Elétricas, Acionamentos e Energia– DELET – Universidade Federal do Rio. Grande do Sul. 4th International Conference on High ...
>318* Read TOEIC Premier 2018-2019 with 4 Practice Tests: Online + Book + CD ... and career services for individuals,
▻Simple test setup. ▻Using adapters to existing equipment ... ▻Read initial
position of C4, T1, T8, and L1 using inclinometer from stand or tilt sensors ...
Page 8 ...
One of the authors certifies that he. (CD), or a member of his or her immediate family, has received or may receive payments or benefits, during the study period, ...
Ambient Air Density Variation. ➢ Density variation is within 7.5 % as allowed by
ECE and Indian Regulation upto temperature of 44 deg C. Reference.
Proposal for C/D Test Temperature Range
India Presentation 5th June, 14th DTP Meeting, Geneva.
Ambient Air Density Variation Reference Condition: Reference Temp (degC)
20
Pressure (kPa)
100
Density (kg/m3)
1.19
Reference Formula :
* Source: TAP115/116
Temp. O C
Atm Pressure, hPa
Air density
Variation of Density from STD
5
1013.25
1.270
-5.41
20
1013.25
1.205
0.00
23
1013.25
1.192
1.02
25
1013.25
1.184
1.68
35
1013.25
1.146
4.88
40
1013.25
1.127
6.40
44
1013.25
1.113
7.58
Density variation is within 7.5 % as allowed by ECE and Indian Regulation upto temperature of 44 deg C.
C/D Testing at Different Ambient Condition To address the open point regarding C/D Test Temperature Range (i.e. 5~35 degC) C/D test conducted at different ambient conditions on test track as per ISO requirements were compared. Tests were done on two vehicles. The test results were corrected using the methodology as per the calculations provided in current Regulation. The corrected values were compared with tested (uncorrected) values for each vehicle to evaluate the efficacy of the temperature correction formula.
Ambient Test Conditions C/D test was done on the 2 different vehicles at different ambient conditions on test track.
Sl. No.
Parameters
Units
Condition 1
Condition 2
1
Temperature
deg C
38 ~ 40
32 ~ 34
2
Humidity
%
14~35
46~65
3
Atmospheric Pressure
hPa
980~985
992~995
4
Average Wind speed
m/sec
0.3~4.1
0.5~1.9
Test Results Summary “without correction” Vehicle
Test Condition
F0 (N)
F2 (N/kmph2)
P[50], kW
P[100], kW
1
97.02
0.0314
2.44
11.41
2
98.75
0.0339
2.55
12.15
-1.78
-7.93
-4.53
-6.48
1
127.93
0.0345
2.97
13.12
2
130.17
0.0375
3.11
14.02
-1.75
-8.74
-4.56
-6.85
A Percentage Difference [(1-2)/1*100] B Percentage Difference [(1-2)/1*100]
Considering the RLD co-efficient values without correction : The difference in F0 value is about 2% whereas the difference in F2 value is 8%. The effect of temperature and pressure variation is more dominant on the F2 value because of air density variation.
Test Results Summary after correction Vehicle A
Test Condition
F0 (N)
F2 (N/kmph2)
P[50], kW
P[100], kW
1
111.75
0.0356
2.79
13.00
2
110.16
0.0356
2.77
12.94
1.42
0.08
0.83
0.40
1
147.33
0.0391
3.40
14.95
2
145.61
0.0395
3.39
15.02
1.17
-1.05
0.28
-0.44
Percentage Difference [(1-2)/1*100] B
Percentage Difference [(1-2)/1*100]
Considering the RLD co-efficient values after temperature and pressure correction : The difference in F0 and F2 value is about 1%. The effect of temperature and pressure correction significantly compensates for the variation in F2 value. The RLD co-efficients corrected from higher temperature range are higher than that corrected from lower temperature range.
Conclusion The uncorrected results at the two different test conditions differ by 5%. The test results obtained at the different ambient conditions show good co-relation when the correction factor is used. The difference in the test results is about 1%. Density Variation is within 7.5% w.r.t reference upto a temperature variation upto 44deg C. Temperature correction holds good for correcting RLD co-efficient values upto 44 degC.
The proposal of temperature range (5~40deg C) could be considered a good compromise for a Harmonized Solution, keeping in mind the average Indian ambient atmospheric conditions and robustness of the correction procedure.