Red And Orange Wire Positive (+). Black And Brown Wire Negative(-). * Weight ... Noise is measured in anechoic chamber i
GFB 80 x 80 x 89 MM SERIES ■ DIMENSIONS

DRAWING

80.0±0.5 (3.150±0.020) 71.5±0.3 (2.815±0.012)

80.0±0.5 (3.150±0.020) 71.5±0.3 (2.815±0.012)

38.0±0.5

50.8±0.5

(1.496±0.020)

(2.000±0.020)

2-4.0±0.3 (2-0.157±0.012)

2-4.0±0.3 (2-0.157±0.012)

LABEL

10.0 (0.394) 355.0±10.0

UNIT:

(13.935±0.394)

& Q CURVE (AT RATED VOLTAGE)

MODEL

■ MOUNTING

3.95

100.0

3.16

80.0

2.37

60.0 40.0

0.79

20.0

0

0

DH

0

0.9

0

40

1.8

2.7 80

3.6 120

INLET SIDE

77.4 (3.047) 71.5 (2.815)

77.4 (3.047) 71.5 (2.814)

1.58

OUTLET SIDE

4-ø4.5 (4-ø0.177)

4-ø4.5 (4-ø0.177)

4.5 (M3/MIN) 160

77.4 (3.047) 71.5 (2.815)

77.4 (3.047) 71.5 (2.814)

120.0

(mm H2O)

Air Pressure

GFB0812XU 4.74

PANEL CUTOUT

(ø ø8 3 . 8. 48 6 8)

■P

(IN H2O)

* Bearing Type Ball Bearings * Material Impeller & Frame : Plactic (UL 94V-0) * Lead Wires : UL 1061 AWG #24 OR Equivalent Red And Orange Wire Positive (+) Black And Brown Wire Negative(-) * Weight : 430g (15.17 OZ)

(CFM) UNIT:

Air Flow

Rated Voltage

Operating Voltage Range

Input Current

Input Power

Speed (Front/Rear)

Maximum Air Flow

mm (INCH)

(ø ø8 3 . 8. 48 6 8)

8-ø4.5±0.3 (8-ø0.177±0.012)

Maximum Air Pressure

mm (INCH)

Noise

PART NO.

FUNCTION

VDC

VDC

Amp

Watt

R.P.M.

m3 /min

CFM

mmH2O

IN H2O

dB-A

GFB0812DHU

-R00 / -F00

12

7.0 to 13.2

5.88

70.56

9200/9480

4.093

144.58

96.54

3.800

73.5

* Function type is optional. * The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow. * Noise is measured in anechoic chamber in free air, one meter from intake side. * All readings are typical values at rated voltage. * Specifications are subject to change without notice.