Agilent 7700 Series ICP-MS Extraordinary design. Unparalleled performance.

The Agilent 7700 Series ICP-MS Advancing ICP-MS technology. Simplifying trace metals analysis. Whether you need to analyze hundreds of complex samples in less time, or confidently detect ultra trace metals in high purity reagents, Agilent’s 7700 Series ICP-MS can help you meet the analytical challenges of today... and of the future. The 7700 Series redefines the benchmark for ICP-MS: more productive, simpler to use, higher sensitivity, lower backgrounds, better interference removal, increased flexibility, easier to maintain and service. All within the smallest commercial ICP-MS mainframe ever made. The robust workhorse 7700x is the instrument of choice for most applications, and in high-throughput commercial labs, the all powerful 7700s is designed specifically for semiconductor applications, and the new 7700e offers a simplified and easy to use system for routine analysis. Featuring a new, configurable MassHunter software platform and a host of hardware developments, including a new frequency-matching RF generator and 3rd generation Octopole Reaction System (ORS3), all three 7700 Series mainframes provide unrivalled levels of performance and ease of use, while delivering results you can trust – even in the toughest sample matrices.

The Agilent 7700x ICP-MS provides unparalleled accuracy in high-matrix samples, redefining cell performance in helium mode with a revolutionary 3rd generation cell design – the ORS 3.

To learn more about the Agilent 7700 Series ICP-MS, visit www.agilent.com/chem/ICPMS. 2

Forward-thinking innovation High Matrix Introduction (HMI) kit

Extraordinary 3rd generation ICP-MS

The unique patented HMI, standard on the 7700x, enables high dissolved solids samples (such as undiluted seawater) to be run directly – a first for ICP-MS. Page 6

As ICP-MS has evolved over the last two decades, Agilent has been the driving force in the technique’s development, introducing many key innovations. With the 7700, we build on this legacy by bringing ICP-MS into the world of routine laboratories and non-expert operators, through new levels of performance, reliability and automation.

ShieldTorch System (STS) The Agilent STS is a key feature of the 7700 Series. It provides effective plasma grounding, reducing and narrowing the ion energy spread – essential for optimum interference removal in He mode. Page 6

Robust enough for your complex matrices The 7700 has been developed to handle the toughest sample types with ease, due to its high-performance sample introduction, matrix tolerant interface and fast, frequencymatching RF generator.

Octopole Reaction System (ORS3) Works effectively using He mode, for simplified operation and consistent results, even in complex sample matrices. Page 4

A unique 3rd generation collision/reaction cell is utilized in all 7700 Series instruments to remove spectral interferences that might otherwise bias results. Helium (He) mode is already established as the only reliable cell method for complex and variable samples, because it filters out all polyatomics, even unidentified ones.

Backed by more than 15 years of ICP-MS leadership Agilent 4500 Series

He mode in the 7700 Series benefits from an innovative new ion lens and 3rd generation cell design, together delivering higher sensitivity, lower backgrounds and more effective interference removal – eliminating the need for reactive cell gases in most applications.

The world’s first benchtop ICP-MS, featuring full computer control, Auto Tuning, and superior cool-plasma performance using our proprietary ShieldTorch System. Nearly 1000 units installed worldwide.

Simple enough for your routine analysis Agilent 7500 Series

The 7700 Series provides many user-friendly features that reduce training costs and improve productivity:

The flagship successor to Agilent’s 4500 Series – and the most widely used ICP-MS in history, with almost 3000 units installed worldwide.

• Reproducible operation from day to day and instrument to instrument, using one-click pre-set plasma conditions • Consistent, reliable operation with Expert Auto Tuning – the fastest, most effective system optimization program ever developed for ICP-MS • One-touch access to the interface area, plus easier sampling cone removal/refitting during routine maintenance • Powerful new MassHunter software platform for enhanced data analysis and reporting

3

ORS3 – unmatched interference removal in complex matrices process chemicals), but reactive cell gases cannot be used successfully for multi-element analysis in complex, unknown or variable samples because:

Removing polyatomic interferences in ICP-MS The 7700 incorporates a newly-developed 3rd generation Octopole Reaction System (ORS3) with improved ion focusing and increased collision efficiency. ORS3 redefines the capability of He mode, and delivers unmatched performance for multi-element analysis of complex sample matrices.

• Each reaction gas will only remove interferences which react with that cell gas, so unreactive polyatomic ions remain, leading to residual interferences. • Users must know which interferences they want to remove, before selecting the reaction gas – not possible with unknown or variable samples.

Reliable results with He mode ICP-MS delivers simple spectra, compared to optical spectroscopy techniques, such as ICP-OES. However, the plasma, solvent and sample matrix give rise to polyatomic interferences on many analytes, so modern quadrupole ICPMS instruments employ a collision/reaction cell (CRC) to reduce these interferences.

• All reaction gases form reaction product ions, creating unpredictable new interferences in complex samples. • All reaction gases react with some analytes, leading to lower signals in reaction mode. For example, severe loss of sensitivity has been reported for Cu and Ni when H2 or NH3 cell gas is used.

Most CRCs only operate with reactive gases, which must be targeted at specific, known interferences on individual analyte isotopes. Reaction mode can be effective when the interferences are predictable and constant (i.e. in simple, consistent samples such as high-purity semicon

He mode on the 7700 provides simple, consistent and reliable analysis of unknown samples, with no new interferences and no reactive signal loss for analytes.

Interference removal using He mode and Kinetic Energy Discrimination (KED) Energy distribution of analyte and interfering polyatomic ions with the same mass

Polyatomic ions Analyte ions

Bias voltage rejects low energy (polyatomic) ions

Polyatomic ions

Analyte ions Energy

Energy

At cell entrance, analyte and polyatomic ion energies overlap. Energy spread is narrow, due to ShieldTorch System.

Residual Energy

Analyte Polyatomic

By cell exit, ion energies no longer overlap; polyatomics are rejected using a bias voltage “step” (energy discrimination)

Energy loss from each collision with a He atom is the same for analyte and polyatomic ion, but polyatomics are bigger and so collide more often.

Cell Entrance

Distance Through Cell

Cell Exit

To learn more about the Agilent 7700 Series ICP-MS, visit www.agilent.com/chem/ICPMS. 4

One 7700 Series, three models, configured for your application The Agilent 7700x: Powerful ICP-MS workhorse for most standard routine and high-matrix applications The 7700x is configured for routine analysis of high matrix samples, and includes HMI, pre-set plasma conditions and He mode ORS3 as standard. With its high-temperature plasma (low oxides), matrix tolerant interface, and 9 orders dynamic range, the 7700x provides the analytical performance required in busy routine laboratories, but also retains the hardware and software flexibility to handle more advanced research applications. Many of the features expected of the highest specification ICP-MS systems are standard on the 7700x, making it suitable for most challenging analytical tasks. A range of options and accessories is available to further customize the 7700x for advanced applications, such as discrete sampling; chromatographic coupling; and analyzing organic solvents, highly corrosive acids, and more.

The Agilent 7700s: High performance for high-purity semiconductor applications The 7700s is configured for the analysis of high-purity materials such as those monitored in the semiconductor industry. With a high-efficiency sample introduction system, optional 5th plasma gas line, and second (reaction) cell gas line as standard – the 7700s offers high performance for the removal of intense interferences in known and consistent matrices. For laboratories that currently utilize cool plasma, the 7700s makes the transition to the most up-to-date ICP-MS technology easy. With unmatched cool plasma capability, the 7700s delivers industry-leading performance for the measurement of easily ionized elements in high-purity materials (for example, Ultra Pure Water), allowing all common semiconductor analytical methods to be performed on the same instrument.

The Agilent 7700e – Simplified operation for routine applications If you’re looking for an affordable route to high-performance ICP-MS, look no further than our 7700e, which includes He mode ORS3 and core software functionality. The 7700e provides a simple, highly automated user interface and standardized hardware configuration, while field upgrades to full 7700x specification are available, should lab requirements change in the future.

Agilent offers Standard Operating Procedures for all common semicon sample types to simplify your method development. 5

Sensitivity and reliability by design Every component of the 7700 Series is engineered for performance and usability

Sample introduction

Electronic gas control

A low-flow, Peltier cooled sample introduction system increases operational stability and consistency (standard on all 7700 mainframes).

Proprietary Active Mass Flow Controllers deliver precise control of all plasma and cell gases.

Interface and cones Robust, standard Ni, or optional Pt tipped cones are easy to access and remove/replace during routine maintenance (no tools are required for removal and refitting of the sampling cone). Torch position automatically realigns with the interface following maintenance to the torch or cones.

Patented High Matrix Introduction (HMI) kit Increases matrix tolerance up to 10x compared to conventional ICP-MS instruments. HMI also improves plasma robustness, virtually eliminating matrix suppression (standard on the 7700x).

Off-axis ion lens

Plasma RF generator

Provides continuously focused ion transmission, and the lowest mass bias of any ICP-MS. In addition, the ion lens is located outside the high vacuum region, making it easy to access for scheduled cleaning.

This fast, frequency-matching RF generator increases the tolerance of changing matrices. Even volatile organic solvents can be introduced without affecting plasma stability. Includes ShieldTorch System as standard, providing the narrow ion energy spread required for effective interference removal in He mode.

Vacuum system A single, high-performance split-flow turbo pump (pictured right) and single external rotary pump ensure fast pump-down and simple maintenance.

To learn more about the Agilent 7700 Series ICP-MS, visit www.agilent.com/chem/ICPMS. 6

High temperature 27 MHz plasma

3rd generation Octopole Reaction System (ORS3)

Fast simultaneous dual mode detector (9 orders dynamic range)

Cell gas inlet HMI gas inlet (7700x) Low flow sample introduction system

High-frequency hyperbolic quadrupole

Off-axis lens

High-performance vacuum system

Octopole

Frequency-matching RF generator

Cooling airflow Provides effective cooling of all components, even in the world’s smallest benchtop ICP-MS cabinet. All air is ducted through a single exhaust vent.

Octopole Reaction System (ORS3)

Hyperbolic quadrupole

This new temperature-controlled collision/reaction cell has a low internal volume, making it ideal for high cell pressures and rapid cell mode switching. No more compromised mixedgas conditions.

The only hyperbolic quadrupole used in ICP-MS delivers superior peak separation and abundance sensitivity, without needing custom quad settings to separate adjacent peaks.

Electron multiplier detector Octopole ion guide

Provides a full 9 orders dynamic range with standard hardware and operating conditions. Integration time is short (100us) in both pulse and analog mode.

Provides high ion transmission and superior focus, ensuring minimal ion scattering at high cell pressures. This enables efficient operation in He mode, and delivers lower detection limits without the drawbacks of reactive cell gases.

7

Extend the power of your 7700 ICP-MS with a wide range of options and accessories Whether you need to maximize sample throughput, achieve the lowest detection limits or separate the different chemical forms of an element, Agilent offers a range of configurable options for the 7700 Series – plus the know-how to help you achieve your specific application goals.

Sample delivery systems Agilent Integrated Autosampler (I-AS). Integrated, covered autosampler with pumped rinse station; ideal for ultra-trace analysis and small sample volumes (as low as 0.5 mL). Flexible rack configurations offer a maximum capacity of 89 vials, plus 3 rinse vials. Service support and warranty by Agilent. I-AS

Agilent ASX-520. Ideal for medium to high sample throughput applications, with rack configurations providing up to 360 vial positions. Service support and warranty by Agilent. Nebulizer. Agilent offers nebulizers to suit every sample type and volume, including low-flow, concentric and parallel path.

ASX-520

Agilent Integrated Sample Introduction System Discrete Sampling (ISISDS). Delivers reduced matrix loading and improved productivity in high-throughput laboratories, with USEPA compliant triplicate analysis of 30 elements or more in 75 seconds, sample to sample.

ISIS-DS

Option gas line for 7700x. Suitable for applications that require a mixed carrier gas, such as O2 for organic solvents or LC mobile phases, and helium carrier gas for laser ablation (standard on the 7700s). Inert Sample Introduction kit. O-ring-free and manufactured from PFA for the lowest contamination levels. Demountable torch with Pt or sapphire injector options. HF resistant, and suitable for high-purity reagents. Laser ablation. With its fast simultaneous detector and 9 orders dynamic range, the 7700 is ideally suited to the direct analysis of solid samples – both bulk and time-resolved – by laser ablation. Organics kit. Contains the sample introduction parts you need to run volatile organic solvents. Includes organics torch, solvent-resistant drain kit and uptake tubing.

To learn more about the Agilent 7700 Series ICP-MS, visit www.agilent.com/chem/ICPMS. 8

Proven speciation capability simplifies the routine use of ICP-MS as an elemental detector for separation technologies

Agilent’s 7700 ICP-MS links seamlessly with HPLC, GC and CE systems through field-proven and supported interfaces, integrated software control, documentation, and fully developed application kits.

Industry leading speciation measurement Emerging environmental, food safety and consumer product regulations increasingly include the requirement to identify and quantify compounds as well as total elemental concentrations. Therefore, routine, accurate speciation analysis has never been more important. As the leading supplier of ICP-MS and chromatography systems, Agilent can help you identify the right system for your application, develop methods and train your staff. We can also provide you with support engineers who are factory trained on all parts of the coupled system. 7700 Series ICP-MS with 7890A GC system

Field-proven and supported LC and GC interfaces Pre-configured LC-ICP-MS kits are available for turnkey methods, such as As speciation in water and urine. The unique GC-ICP-MS interface is heated to the tip of the injector (up to 300º C) for routine analysis of high-BP compounds. In addition, the inert, fully heated (Sulfinert™ lined) interface provides unparalleled performance for advanced GC-ICP-MS applications, such as separating siloxanes, brominated flame retardants, and sulfur species in fuels. 7700 Series ICP-MS with 1200 Series LC system

Optional software for integrated LC- and GC-ICP-MS The 7700 Series MassHunter software provides seamless setup and operation of coupled chromatographic systems, with direct method setup and run control for Agilent LCand GC-ICP-MS systems, and simple links to many other separation techniques. The optional chromatographic data analysis software has the same user interface and layout as the spectrum data analysis software, simplifying operation.

ICP-MS MassHunter WorkStation – Chromatographic Data Analysis

9

Intuitive, configurable MassHunter software simplifies your daily workload Instrument control and data acquisition

Data analysis in a single, clear window

From automated startup checks following plasma ignition, through batch and queue method setup and sequencing, to integrated data processing and final report generation, our new ICP-MS MassHunter Workstation software makes running your Agilent 7700 easier than ever. It includes:

The flexible, customizable batch-at-a glance data table provides a comprehensive overview of the current batch, including counts, concentrations, RSD and replicate data. It includes: • Real-time results update during sequence acquisition

• Expert AutoTune technology and application-specific preset methods that enable even novice operators to quickly produce reliable, consistent results

• Interactive calibration plot display (12 plots or single plot), with real-time update after edits and during sequence • On-screen display and flags for user-selected outliers and QC failures; built-in LabQC sample charting

• Simplified user interface and navigation: a single control pane provides a comprehensive overview of hardware configuration, performance reports, early maintenance feedback, and system diagnostics

• Graphical display of internal standard recovery, QC stability plots, calibration curves and mass spectrum (or chromatogram)

• Batch and queue interface puts critical method setup and sample analysis at your fingertips:

• Easy-to-edit report templates for print, screen or electronic output (including direct export to LIMS); templates can be used for individual samples or a complete data batch

• The batch pane displays tune settings, acquisition/data analysis parameters, and sample list

Powerful software, consistent across Agilent MS platforms

• The queue pane displays current and scheduled tasks, current batch sequence, and real-time status of the current sample

Agilent’s MassHunter software family now includes ICP-MS, LC/MS, and GC/MS, simplifying and reducing the cost of cross-training staff.

For compliant environments, the MassHunter software can also be integrated with Agilent OpenLAB ECM.

To learn more about the Agilent 7700 Series ICP-MS, visit www.agilent.com/chem/ICPMS. 10

Robust operation in a streamlined design Agilent’s 7700 Series has been engineered to endure the toughest lab environments, while delivering operational cost savings through higher productivity, shorter training times, simpler method development, and lower service requirements (particularly important in clean-room installations).

7700 Series: breakthroughs in environmental impact reduction

High reliability boosts uptime and productivity • Lower heat output and reduced exhaust vent flow (7700s), with a redesigned cooling air-flow management system

Like all Agilent ICP-MS systems, the 7700 Series is built for high sample capacity and a healthy return on your investment. The 7700 is manufactured at an ISO 9001 and ISO 14001 facility and features:

• Less sample volume required, so there is less waste for disposal

• Rugged stainless steel chassis and outer panels

• Stainless steel outer panels that require less paint and associated solvents

• Extensive shock, vibration, temperature and humidity testing at the production prototype stage to ensure optimum performance, even under extreme conditions

• At only 115 kg, the 7700 mainframe weighs 30% less than the 7500 Series, significantly reducing CO2 emissions during transportation

• Auto-recover – saves time by safely returning the 7700 to Standby state when power is restored following a power cut • Predictive Maintenance software to minimize unplanned downtime • Advanced error reporting and system diagnostic tools that simplify troubleshooting • A modular design for shorter repair times

Designed to benefit your lab and our environment From a 30% reduction in mainframe weight (compared to the 7500), to increased use of recyclable materials, to fewer toxic compounds in electronic components – the 7700 is the first ever ICP-MS designed and manufactured for lower environmental impact.

11

Maximize your productivity and data quality with genuine Agilent parts and supplies From our proprietary ICP torch, to our sample and skimmer cones, to our unique electron multiplier detector – Agilent ICP-MS parts and supplies are manufactured to our tight tolerances and stringent specifications. They are also rigorously tested to ensure that you’ll always get the best performance from your instrument, and the best results for your clients.

Trust Agilent to keep your lab running at peak productivity Agilent’s Advantage Service protects your investment in Agilent instruments and connects you with our global network of experienced professionals who can help you get the highest performance from every system in your lab. Count on us for the services you need at every stage of your instrument’s lifecycle – from installation and upgrade to operation, maintenance and repair. For customers who require full system validation, Agilent offers complete qualification services (Installation and Operational Qualification) for the 7700 Series ICP-MS hardware and software. And if ever your Agilent instrument requires service while covered by an Agilent service agreement, we guarantee repair or we will replace your instrument for free. No other manufacturer or service provider offers this level of commitment.

The Agilent Value Promise: 10 years of guaranteed performance In addition to our continually evolving products, Agilent offers the industry’s only 10-year value guarantee. Agilent guarantees you at least 10 years of instrument use from your date of purchase, or we will credit you with the residual value of that system toward an upgraded model. It’s our way of assuring you of a safe purchase now, and protecting your investment in the long run.

Research use only. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. © Agilent Technologies, Inc. 2010 Printed in USA July 13, 2010 5990-4025EN

For more information Learn more: www.agilent.com/chem Buy online: www.agilent.com/chem/store Find an Agilent customer center in your country: www.agilent.com/chem/contactus U.S. and Canada 1-800-227-9770 [email protected] Europe [email protected] Asia Pacific [email protected]