information system. A software package called Osiris is being used for the display and manipulation of medical images in a hospital-based picture archiving and.
Multimedia
Image
and Data Navigation Workstatio& Osman
Ratib,
PhD
Marianne
#{149}
Trayser,
PhD
MD,
Eng
Logean, #{149}
Denis
images,
extracted
package
called
images
PhD
#{149}
Christian
#{149}
Hochstrasser,
Christian
Girard,
Pro!,
Mascarini,
MSc
Gerhard
#{149}
MD
standards have been established for the transmission on medical information and records, including mcd-
from
Osiris
Ligier,
MSc
World Wide Web (WWW) of and remote consultation ical
Yves
#{149}
an
is being
in a hospital-based
existing
used
hospital
information
for the display
picture
archiving
system.
A software
and manipulation
and
of medical
communication
system.
Re-
cent extensions of Osiris, through the integration of WWW navigational tools, allow easy access to a variety of clinical data from patient records. A special interface allows access to radiologic images, laboratory results, and related textual information through public-domain software programs. These technologic advances
offer
made
medical
WWW
and
professionals
Internet
the
navigation
convenience
so popular
and in the
ease
of use
academic
that
have
community.
U INTRODUCTION One
of the
fords
major
advantages
to transmit
the
these images with cessibility of these cialists
in large
of digital
images
archiving
to multiple
of medical
locations
for
images
immediate
other medical data as part of a patient’s medical images is of great value to referring physicians
multidisciplinary
hospitals,
although
images
of a hospital
aspects.
Such
which as text
allows reports,
be one
of the
institutions
dated
information
major
“legacy”
ESQL OSF
language,
terms:
(PACS)
See
the
are
development on
different
not
suf-
view
of a unified
of all these
user
interface,
through various Such accessibility
types of data, such to data used to
of an integrated
HIS,
systems,
some
especially
of which
may
in
be
out-
= =
embedded Open
structured
Software
query
Foundation,
language, PACS
=
HIS picture
=
hospital
archiving
information and
system.
communication
HTML
=
system.
hypertext WWW
=
Computers,
multimedia
Images.
storage
and
retrieval
Picture
#{149}
archiving
and
communication
system
Workstation
#{149}
the
1997; Digital
17:515-521
Imaging
Geneva 14, Switzerland. 1996; revision requested c RSNA,
in the data
generally
acspe-
are not concurrently in databases separate Today, one of the main
an integrated
development
“browse” and images.
are
The
Web
RadioGraphics From
difficulties
is to provide the
it af-
to link
systems.
markup
Index
(HIS)
requires
to conveniently data, graphs,
different
Abbreviations: Wide
usually
physicians numerical where
World
system
integration
ability and
record (1). and consulting
alone
ficient if corresponding medical records (eg, laboratory results) available. In most institutions, images are stored and manipulated from those in which other aspects of patient records are stored. tasks
is the display
tJnit,
Department
of Radiology,
University
Presented as an infoRAD exhibit at the June 14 and received July 30; accepted
Hospital
of Geneva,
1995 RSNA scientific August 1 3. Address
24 rue
assembly. reprint
Micheli
Received requests
du
Crest,
February to OR.
121 1 29,
1997 commentary
by Greenes
and
Chang
following
this
article.
515
With
Wide
the
increasing
Web
widespread
the
popularity
(WWW) availability
trend
tools
and
of computer
has
been
for
exploring
standards
of World
navigational
the
browsers,
for developers
to usc
all types
of data-in-
WWW
Patient databases
cluding, of course, medical data, particularly where the need exists to access multimedia data consisting of images, numerical data, graphs,
and
textual
documents.
ers offer a convenient ing applications easily different
databases
of integration
WWW
brows-
way to customize for data extracted
while
viewfrom
maintaining
in a single-user
Image Archives
FTP transfer)
(me
Query program
a degree
‘I,
1%-
environment.
Query and retrieval of different types of data from multiple databases can be performed easily from
WWW
lished
The through
with
a well-estab-
paradigm
(Fig
1).
usc of WWW tools for navigating medical records is being explored
variety our
browsers
client-server
of applications. experience
In this
at the
article,
University
in a
we
report
Hospital
Figure
of
Geneva (Switzerland) with a new approach to providing a large number of users with convenient access to patient records. This system comprises
an integrated,
workstation
multimedia
environment
gational
tools
imaging
viewers.
combined
with
The
information
on
WWW
specific
software
related communication the advantages of the tional
medical
based
1.
medical
the
databases.
images
cation
architecture
and
The
GENEVA
tradition
are
FTP
ers
discussed.
HIS
Hospital
of Geneva
in developing
its own
has HIS,
a long
called
the
Diogene system (2). This system has constantly evolved since its inception and is currently based on a distributed architecture in which different parts of the medical records are located Ofl different databases linked together through a single
patient
years,
an
obtained
been
with
made
developed our
hospital,
ety of ology other ports)
management
increasing
system.
number
different
available
imaging
in digital
as an
extension
the
Diogene
In recent
of medical
images
modalities
form
of Diogene system
have
with
= file
record
are
sent
a study
to the
to display
transfer
of the
has been
user
and
selected,
a “helper”
and manipulate
appli-
the images.
protocol.
(3).
handles
gathered
by
different
servers.
(OSF)-Motif chines.
these
serv-
network,
they
as part
of a given
A distributed
chitecture different archived. Diogene software interface
At a vari-
Diogenc identified
are
linked
and
patient’s
medical history. The data arc stored in an INGRES database management system on different UNIX-based
a PACS
data, including all laboratory results, radireports, and discharge letters, as well as documents (eg, surgery procedure re(4). Although these different elements of
a patient’s
between
tools arc presented, and new system over conven-
systems
University
of the relationships
After
are
is used
uniquely
U THE
Schematic
the WWW browser and the various parts of the HISpicture archiving and communications system (PACS). Query is performed through a WWW interface to the standard PACS and radiology information
system navi-
OSIRIS viewer (helper application)
browser
www
X-terminal
Macintosh
available offices.
graphical setting
from
(Apple
computers
stations
emulators
applications
cians’
software
and
hardware
ar-
allows a progressive evolution of the parts of the medical record being For data retrieval and display, most applications rely on specially designed programs with an X-Window graphical with Open Software Foundation extensions running on UNIX ma-
This
arc
used
to access
PC-compatible
Computer,
and Calif) and physi-
Cupertino,
in clinical allows
wards
access
to the
same
user interface from both UNIX workand desktop personal computers. This requires that all applications developed
with
an X-Window
user
applications
graphical to be
interface
implemented
allow in a client-
server mode. One major exception to this concept in the Diogene system relates to the retrieval and display of medical images, for which
516
U
info
RAD
Volume
17
Number
2
a specially
designed
Osiris
developed.
was
directly
on the
files
must
tion
before
that
Osiris
be
they
downloaded can
be
image required
of hardware
software
nipulation
was
degree
and
needs
menus,
was
of physicians
sive
of customization.
features
computer
skills.
the generic nipulation,
adapted
and
The
windows,
does
to meet
not
Osiris
icon the
require
provides
exten-
some
of
tions,
inverse
tation,
image
necessary for basic image maas zoom and panning operavideo mode, magnifying glass, roprocessing, and color and contrast
adjustments.
The
designers
special
care
with
the
various
cessing
image
ways,
so that
familiar with of the program. and operation
design lytic
tools
dalities
Osiris
the
applicable is, to our
program
took
a consistent
approach
manipulation
and
(6). Different
tools
in similar
come tures
of the
to provide
tasks the
user
rapidly
lar.
the
Two
basic
the user
components
allow tools:
call-back
the
window
tools
to different
hcuge.ch/UIN/UIN.html.
can
be
can
be
to the
basic The
analysis
and
WWW
manufacturer-
and
in recent
modality-specific Recent developments in PACS have led manufacturers to design systems that can handle and display images from different modalities. However, little effort has been made to unify the different image analysis tech-
tas
niques
in a unique
it was
initially
The oriented
Osiris software programming
of the
WWW
.
ensures
a modular
structure.
gram made ous
Among
is written language and
the
easily main
features
of the
1997
program
tools.
in the objectC++, which
adaptable features
is its portability to different by different manufacturers
fled and customized needs. Most important,
March-April
of standard
can
can
among
OF WWW STANDARDS phenomenal development of the
set
Osiris
of charge and at http://expasy.
The
are
fea-
processing
U USE
that
be
mouse
these and
software.
software is distributed free be obtained on the Internet
can
in which
analysis
added
attributed.
results
Through
advanced
man-
manager. The dialog to create dialog wintypes of elements to
windows
is possible.
more
creation
dialog
manager,
in separate
system in particu-
the
the
operations
data
interaction
underlying
currently available commercial systems. Most manufacturers implement image processing and programs
to
platforms.
interface
ager and the data window manager makes it possible dows containing different
displayed
mo-
from
of system-independent
operation of all the feaThis consistency in the of a large variety of anaimaging
X-Window
of UNIX
graphical
tures,
unique
Win-
and OSF-Motif (extension environments to ensure its
a variety
be-
knowledge,
(both
of Technology
independent from
With
are performed can
library
which
pro-
as for
PC-compat-
95 versions). The UNIX with the X-1 1 (Massa-
developed
for
a van-
Osiris was designed as an extensible platform that allows new tools to be developed easily and integrated into the software. Because these tools must be portable for the different workstations supported by Osiris, it was important to provide the potential developer with a and
tools such
and
Windows
Windows
Institute
portability ma-
some
buttons,
was
for
as well
computers
running
3. 1 and
The
available
workstations
computers
analysis
applications.
is currently
graphical interface) X-1 1) windowing
to perform
of specific clinical
personal
chusetts
Washington).
designed
which
Macintosh
version
as Macrunning
tions
with
implementation specialized
software
such
and analysis of digital medical images be used in different clinical applica-
interface,
Osiris
dows
(5). It can user
for
ible
SOFFWARE
U 0511115
easy
tools
workstations
computers
Redmond,
low
ety of UNIX-based
worksta-
This
computers
(Microsoft;
Osiris
so that
on a variety
PC-compatible
Windows
runs
to the
UNIX-based
personal
and
called
program
displayed.
be available
desktop
Osiris
workstation,
including
intosh
package
The
local
first
platforms,
and
software
software of the
pro-
workstations (7). The varieasily
be
modi-
in the
domain
years
has
Internet
opened
of worldwide
data
new
vis-
exchange
and data communication. The rapid evolution of the “Web” has extended the possibility of communications among a large number of users far beyond the academic community to which confined. has
been
terfaces for viewing documents, including and
animation,
through
The
major
to offer
innovation
standardized
in-
and linking multimedia images, texts, sounds, standard
wide availability of software low display and manipulation of data on different hardware
protocols.
The
programs that alof various kinds platforms has
to meet different user Osiris is designed to al-
Ratib
et al
U
RadioGrapbics
U
517
made
the
exchange
universally which
makes
communication
and
attractive.
The
it possible
to link
document to other documents, ages and sounds, has opened navigate across the different dition,
WWW
trigger
different
browsers
of data
hypertext parts
the
JLJ
imto In ad-
capacity
for displaying
to
of data. Every time a new type of document is referred to, appropriate software can be added to the list of programs, often referred to as “helpers” or “viewers,” that can be triggered from the browsers to display the data. capability
is obviously
an
attractive
of displaying data such as medical documents. With a tool designed and manipulating medical images them to existing WWW browsers, to use
the
remote
existing
Web
consultation
This
new
for
technology
was
(Macintosh,
PC
the
documents. tion and
A large up-to-date
confidential
recently
(8).
imple-
UNIX),
exchange
amount medical
C, 15i
s
44’naCR.4.
4#{149} ptLp1#{149}t
9
4’
,‘#{149},-
4u
[4iiii
#{149}p.tt#{149}1)
c=#{149} , tm,
‘-#{149},{149}, -
r----r--
jwy
t.345
-
]
I-
-
psr
pairuc
I.
Im HEAl’
de #{232}i.M.s PAS
-
h.’-,
.
A=t#{149}#{149} tip.
4*.*4.11t#{233})_________
2. First WWW page for a PACS database query. This page allows the user to make selections with a simple set of search criteria.
able on different on any computer, used in private tion,
a special
tocol
was
cess
servers and since they practitioners’ proprietary
established
to patient
can be retrieved are now widely offices. In addi-
communication
to allow
data
such
pro-
confidential
as laboratory
acresults,
reports, images, and other graphics through the exchange of the corresponding files, which can be consulted further on any computer with use of the appropriate viewer linked to the WWW browser. This solution should prove superior to the tedious, older communication protocols that are often used to exchange data between different laboratories and clinics. Standardization
efforts
are
also
community to allow ments across different
being
the
made
in the
exchange platforms.
medical
of docu-
it is
ideally suited for use as a document viewer in the conventional Web architecture. Beyond just using the Web browsers inside the hospital for retrieving and viewing parts of the computerized medical record, the Internet also facilitates the exchange of medical documents on a much larger scale. We recently cxplored this technologic advance through the implementation of a public server that would provide convenient, low-cost access through the Internet to medical information and make possible
1* bs1..
of and
documents
Windows,
-
Figure
mented at our hospital, where the conventional PACS environment was replaced with a prototype of the WWW browser that directly triggers a specific program designed for displaying medical images from the conventional Netscape or Mosaic browsers-in our institution, Osiris. Before this modification, a user had to perform a tedious series of database queries and file transfers to retrieve images obtained of different patients. Now, to retrieve images, the user can work through a specially designed interface written in hypertext markup language (HTML) from any conventional WWW browser on any platform. In addition, because the Osiris program was written for different hardware platforms
-
ds
means
images or for displaying and linking it is possible
transmission
on medical
-
.cI,cbs
#{149}
differ-
ent types
This
Jiii
=Lii
of a text
including a new way sets of data.
have
programs
ro
concept,
of medical
of relevant informadata are also avail-
U CURRENT
IMPLEMENTATION
AND
FUTURE DEVELOPMENT To explore the possibilities and advantages of the WWW as an extension of the conventional PACS environment, we elected to use currently available navigational tools such as Mosaic and Netscape that are available on all hardware platforms (9). A special effort has been made to provide intuitive access to the data by developing programs written in languages such as PERt, CGI, and C. These programs can assist the user in accessing remote databases or information servers to retrieve and display the results
of a search.
One
major
advantage
of using
WWW facilities to access PACS databases is their ability to treat text, images, or movies in a similar way by selecting different viewers adapted to the type of data being retrieved. Data protection and access control may be among the most important features of a WWW-
518
U
infoRAD
Volume
17
Number
2
-
-
Figure
3. WWW query selected image. After the study and image set have
lected from the WWW images are downloaded workstation
and
cally with
page
query page, to the local
displayed
the Osiris
and a
appropriate been se-
automati-
image
analysis
software.
based PACS system. In our hospital, a selective control is used to allow user identification and checking of access rights as defined by our cxisting HIS to provide limited access to the data and adequate protection of confidentiality. User identifIcation is achieved through a simple interface (Fig 2) similar to that used for all other standard applications of our HIS. After the user’s tion
name
and
is made
password
are
by querying
the
given, central
concerning the rights owned by that given workstation. All the applications are described in the database, making sible
to allow
tion
accessible
user
may
images
be
and
access from allowed
reports
to only
part
the
servers
HIS
access
but
not
The second stage consists of choosing among the different examinations performed on the patient by clicking on one or more check box buttons. To help the user make a more selective choice, some information relative to each
identifica-
examination is shown next to each entry. The third and last stage consists of choosing the image files to be retrieved. Depending on what configuration of the WWW browser is
database
being
user at the rights it pos-
of the
informa-
(eg,
(Fig
a given
to the radiologic to the laboratory
re-
sults).
Image data arc accessed in a three-step procedure that mirrors the PACS database structure whereby the user selects a subset of images from the PACS database. First, the user is requested to complete several query fields to restrict the number of records being extracted from the database (Fig 2). These query fields indude the patient’s name, sex, and date of birth; the examination identification number; the interval during which the research will be carried out; the anatomic part (eg, chest); and the modality (eg, computed tomography). Once the selection fields are filled, the user can trigger the search process, activating a special program on the server machine that gathers all the information given by the user and translates it into embedded structured query language (ESQL) to transmit the query to the database and obtains the results of the search, which arc displayed HTML in the WWW browser window.
March-April
1997
used,
these
images
can
either
be
simply
downloaded onto the workstation local disk for temporary storage or directly displayed by launching the Osins software automatically 3).
At every stage, the user has the option of searching directly for the radiologic report associated with a given examination by clicking on the patient’s name. This action triggers a hyperlink that starts an ESQL query to the reports database, called Unidoc, to retrieve and display the chosen report. The Unidoc reporting system
has
system.
been
developed
as part
It was
designed
to archive
of the
Diogene
patients’
tex-
tual medical records, produced on a personal computer running Microsoft Word, into an INGRES database. All collected documents are structured paragraph by paragraph with an associated set of keywords for archiving and retrieval
purposes.
mation
regarding
database tion
number
and
In addition, patient
is related for
the
all detailed identification
to the patient
unique in the
inforis in the
identificaHIS.
in
Ratib
et al
U
RadioGraphics
U
519
jrj..LJ-I::I’I
U
I
i_,43CJ Figure 4. that allows tory results tabase.
Sequence the user directly
of query pages to gather laborafrom the HIS da-
Li:j---i-i=
-
-Th
t#{149}
.
a
I
I
.
U
1000 Figure
5.
Two
WWW
pages
show
information on a test (left) and a compilation of more detailed information
derived
from
the test (right).
The
I
,,..
user can retrieve ing the biochemical
pects suits.
of each
information regardand technical as-
test,
Laboratory
as well as test re-
are accessed through a 4). The user can select query criteria such as patient number, record number, or date of examination. The query is sent to a service of the HIS via a remote procedure call to retrieve the information collected similar
interface
by
laboratory
the
results
(Fig
database.
The
played on an HTML page that matically. Furthermore, these with hyperlinks to laboratory clinical information related to 6). A special hyperlink allows for the results of other radiologic undergone by the same patient.
results
arc
dis-
is generated autoresults are listed methods and each test (Figs the user to search examinations 5,
U CONCLUSIONS Recent studies demonstrate that the cost-effectiveness of a PACS should not be evaluated relative to the radiology department alone but relative to the entire hospital. The main benefit of a PACS accrues outside the radiology department,
520
U
infoRAD
where
clinicians
will
profit
access
to images
(Fig
7).
from more efficient Access to both images and related data such as the radiologic report, annotations, and results of laboratory analysis is a primary benefit of having a PACS in a clinical setting. Substantial added value is also derived from the image manipulation and processing features that the system provides to clinical uscrs outside the radiology department. Therefore, it is important to allow flexibility in the design
of such
tools
in customizing
the
work-
station software that must be adapted to meet different users’ needs. With these new tools, the PACS environment is made convenient and easy to use, allowing every clinician, even those who are unfamiliar with
computers,
to retrieve
pertinent
radiologic
images, reports, and even laboratory results. Connections between different parts of the computerized medical record can be achieved with hyperlinks and the rest of the WWW hypertext environment that links the Web to the existing distributed databases in an HIS. The use of these tools speeds up the development of software applications and allows developers
Volume
17
Number
2
U
_i
U
I
5SChESIGSI
P.iws
Map Plo. A4
woo 1
Figure
,
.
1
3.
Ratib
0,
#{149}#{149}=#{149} I ,II.,.
PACS.
a
-,.-
au
hoff 7th
4.
_l_
.
1 ‘
.
5.
Figure 7. Two pages from a WWW server that provides information to physicians and private practitioners outside the hospital. The page on the left is the main home page, with links to sources of rel-
exchange shown
6.
documents.
that
vary
Documents
according
dam, Ratib
7.
type.
Switzerland:
sociated on the
with design
Finally,
lated
their
recent
efforts
database consultation of the graphical user technologic
to videoconferencing
interactive
on software
communication
breakthroughs in the remote consultation.
areas
tasks
rather interface.
innovations
and
other
will
lead
as-
than
8.
re-
means
of
to new
of teleradiology
9. and
TE, Rien-
North-Holland
Ed Amster-
concepts.
diagnostic
In: Dc
imaging:
digi-
tal PACS in medicine. New York, NY: Elsevier, 1992; 293-318. Ligier Y, Ratib 0, Logean M, Girard C. OSIRIS: a medical image manipulation system. MD Comput 1994; 11:212-218.
Ligier
Y, Funk
M, Ratib
0, Perrier
interface In: Huang
G, eds.
Picture
R, Girard
for manipulating HK, Ratib 0,
archiving
system
(PACS)
in medicine.
vanced
Science
Institutes
Series.
many: Ligier
Springer-Verlag, Y, Ratib 0, Funk
C.
Bakker
and commu-
nication
Logean M. ware: what to concentrate
JF, Do H,
P, Piemme
1992; 781-787. 0. Evolution of PACS
AB, Witte
are
to data
G, Vuriod
image management in an integrated RIS and
In: Lun KC, Degoulet
The OSIRIS user medical images.
The page on the right shows the mailbox system that allows the
of medical as icons
H, Trayser Distributed storage
Valk JPJ, ed. Integrated
.
M
information. of a secure
biochemi-
0, eds. MEDINFO ‘92: proceedings of the World Congress on Medical Informatics.
Geneva, I.
evant output
Lemke
Scherrer JR. and hierarchical #{149}“#{149} ..
The complete
the map and retrieve additional data regarding that particular substrate from related WWW servers around the world.
___2-_
Ii
6
cal pathways are also displayed graphically on “maps” such as the one shown. The user can even select any biochemical substrate shown on
NATO
Berlin,
1991 ; 395-399. M, Perrier R, Girard
Portable image-manipulation is the extra development
Ad-
GerC,
softcost? J
Digit Imaging 1992; 5:176-184. Bitti M, Matta G, Tuveri M, et al. A WWWbased distributed system for medical data analysis and 3D reconstruction. In: Lemke HU, ed. CAR ‘96: Computer Assisted Radiology. Amsterdam, The Netherlands: Elsevier, 1996; 345-350.
Mascarini C, Ratib 0, Trayser G, Ligier Y, Appel R. In-house access to PACS images and related data through World 2711:531-537.
Wide
Web.
Proc
SPIE
1996;
U REFERENCES 1 . van Gennip
2.
Overview Comput ScherrerJR,
EMSJ, Heiska
An integrated hospital Geneva. MD Comput
March-April
K, Kemerink
GJ, et al.
of CAPACITY data. Int J Biomed 1992; 30:173-180. Baud R, Hochstrasser D, Ratib
1997
information system 1990; 7:81-89.
0.
in
Ratib
et al
U
RadioGraphics
U