Dynamic Modelling and Simulation of Linear Fresnel Solar Field ...

3 downloads 3874 Views 2MB Size Report
Oct 14, 2015 - Field based on Molten Salt Heat. Transfer Fluid ... APROS Dynamic Simulation Software ... Direct connection to two-tank storage system.
VTT TECHNICAL RESEARCH CENTRE OF FINLAND LTD

Dynamic Modelling and Simulation of Linear Fresnel Solar Field based on Molten Salt Heat Transfer Fluid SolarPACES 2015 Cape Town, South Africa, 14th October 2015 Elina Hakkarainen, Matti Tähtinen

Content  VTT Technical Research Centre of Finland Ltd.  Background  The scope of the work  APROS Dynamic Simulation Software

 Basic concept modelled and simulated  Methodology  Model setup in APROS

 Results  Simulation cases  First results of selected cases

 Conclusions and future work

19/10/2015

2

VTT Technical Research Centre of Finland Ltd.  Largest multi-technological applied research organization in Northern Europe  Applied research for needs arising from industry  Customers are Finnish and international companies as well as public sector organizations  Total staff over 2300  High focus in future low carbon energy systems

© VTT

19/10/2015

3

Background  Molten salts gaining much interest as viable HTF option  Several advantageous features  Already demonstrated HTF with line-focusing technologies

The scope of the work is to...  Configure initial model for linear Fresnel solar field with molten salt as HTF in APROS;

© VTT

easy to scale, easy to connect

 Check the proper functionality of the model and new HTF properties  Check the critical points and define needs for new APROS components and features  Demonstrate the feasibility of APROS to study dynamic behavior of CSP applications 19/10/2015

© CSP Today

4

Background: APROS Dynamic Simulation Software  APROS is a software package for modelling and dynamic simulation  Applied in the wide range of processes      

Nuclear power plants Combustion power plants Pulp & Paper mills General heating and cooling processes Smart grids Large-scale solar power

 Developed since 1986 by VTT and Fortum  Users in 27 countries

19/10/2015

© VTT

APROS features:  Accurate process modelling with a set of predefined process components; one-to-one analogous with concrete devices and properly validated  Sophisticated automation & instrumentation system modelling  Electrical system modelling Where can be APROS used?

© VTT

5

Basic concept: Linear Fresnel solar field with molten salt as HTF  Collector row composed of 9 collector components  total length ~ 400 metres  Vacuum tube receivers

 Direct connection to two-tank storage system  Operated at 510 ˚C and 280 ˚C

 HTF: nitrate salt mixture Hitec  53% KNO3 + 40% NaNO2 + 7% NaNO3  Freezing point 142 ˚C  Upper temperature limit 535 ˚C

© SEIA

 Steam generator required  Superheated steam at 450 ˚C and 90 bar

 Solar field over sized in order to produce constant power round the clock  Simple PI-controller based control system  Freeze protection an important issue 19/10/2015

6

© VTT

Methodology: Model setup in APROS Subsystems modelled:     

Solar components: irradiation data Solar field Thermal energy storage system Steam generator Control system

 Fluids properties of Hitec imported to the code by defining polynomial functions for properties as a function of temperature  Homogeneous i.e. 3-equation flow model  Phase change not possible 19/10/2015

7

Methodology: Model setup in APROS Solar Components  Solar Radiation module  Calculates the solar position and further both the beam and diffusive irradiation on a horizontal surface at each time step

coordinates, current standard time, Linke turbidity factor, clear-sky index

solar position, beam and diff. irradiation on hor. surface

 Solar Irradiation Processor module  Calculates the angle at which the beam irradiation enters the tracking surface and further the total amount of dir. and diff. irradiation on the surface

tracking mode, orientation, collector tilt angle

dir. and diff. irradiation on tilted surface

 Alternatively, real measured and forecasted data can be fed to solar field model COLLECTOR 19/10/2015

8

Methodology: Model setup in APROS Solar field Collectors configured as User Components  Includes calculation of both optical and thermal behavior  Calculations carried out by analog components and signals  Mass and heat flows simulated with normal process components  Dimensioning as for any process component  Simplifications:  Only one collector row modelled → multiplication coefficients  Homogeneous heat flux around the receiver tube 19/10/2015

9

Methodology: Model setup in APROS Two-tank thermal energy storage  Hot and cold storage tanks; 510 ˚C and 280 ˚C  Specific energy capacity over storage 74.4 kWh/tsalt  Simple model for two tanks configured  Current APROS version unable to handle interface of own liquid fluid and gas  Calculation based on mass- and energy balances  Constant pressure  Heat losses neglected  Moderated temperature in the tank (at each calculation time step)  Stored energy  Storage inventory 19/10/2015

10

Methodology: Model setup in APROS Steam generator i.e. heat exchanger (HE) train  Thermal power of 17 MWth  Superheated steam at 450 ˚C and 90 bar  Consist of three separate heat exchangers  Preheating, evaporation and superheating parts

 Simple dimensioning according to general heat exchanger designing methods  Standard counter-current heat exchangers from APROS Process Model Library used 19/10/2015

11

Results: Simulation cases  Simulation location: Aldiere, Granada, Spain  37°13′ 50.83″ North and 3°4′ 14.08″ West (Andasol 1)

 Selected simulation cases:  June 21st i.e. summer solstice  March 21st i.e. spring equinox  Full 24-hours i.e. one operational cycle

 Assumptions:  Clear-sky conditions  Monthly mean TL factor and day time temperature  North-South orientation

June 21st

March 21st

TL factor *

3.4

2.4

Ambient temperature [˚C] *

23.3

12.5

Number of collector rows

19

30

Field nominal thermal power [MWth]

45.2

47.7

* Ref. SoDa; JRC

 Varying size of the solar field between cases → to produce constant power round the clock → optimum size for solar field and TES system not considered in this work 19/10/2015

12

Results: Solar field Alternatively measured data can be fed to the model.

Direct horizontal irradiance (yellow) and theoretical DNI on tracking surface (red) on June (solid line) and March (dashed line).

19/10/2015

Molten salt outlet temperature on June (solid line) and March (dashed line).

Solar field thermal power on June (solid line) and March (dashed line).

June 21st

March 21st

Nominal thermal power [MW th]

45.2

47.7

Daily production [MWh]

403.3

408.4

13

Results: TES system and steam generator

Daily variation in hot TES temperature and cold TES temperature on June (solid line) and March (dashed line).

Superheated steam temperature (red) and steam generator thermal power (green) on June (solid line) and March (dashed line).

Control system improvements and optimization. 19/10/2015

Hot tank salt mass (red) and cold tank salt mass (blue) on June (solid line) and March (dashed line).

14

Conclusions and future work  APROS is a very capable tool to handle highly dynamic processes such as solar field operations  To study dynamic behavior  Improve and optimize control systems  Study and improve operation strategy

 APROS could be applied in the field of O&M and trouble shooting as well  Control system development; Model Predictive Control (MPC)  New components can be developed according to user/customer needs in-house (e.g. thermal storage components)  Easy connection (OPC) to other simulation/programming tools (e.g. Aspen, Simulink) 19/10/2015

15

Acknowledgements This work was carried out in the project funded by the European Regional Development Fund and in the ComboCFB (Combination of Concentrated Solar Power with Circulating Fluidized Bed Power Plants) research project coordinated by VTT with funding from the Finnish Agency for Technology and

Innovation, Tekes.

Thank you for your attention!

Poster Session 2: F-02 “Comparison of Measured and Simulated Irradiation Data in Dynamic Process Simulations” By VTT & Vaisala

Elina Hakkarainen [email protected] +358 406 486 799

VTT Technical Research Centre of Finland Ltd. www.vttresearch.com

TECHNOLOGY FOR BUSINESS

Suggest Documents