Examples of Manuscript Components and Description ...

1 downloads 0 Views 1MB Size Report
Hall, 2070 Neil Avenue, Columbus, OH 43220, USA, Email: [email protected]. 8 ... Two current trends in design of tall and special buildings are creating freeform ...... Table 2 lists ŜCT, collapse IDRmax, and their corresponding lognormal ...
1 2 3 4 5 6 7 8

Seismic Performance Factors for Low- to Midrise Steel Diagrid Structural Systems Esmaeel Asadi1 and Hojjat Adeli2 1. Department of Civil Engineering, Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH 44106, Email: [email protected]

2. Department of Civil, Environmental, and Geodetic Engineering, The Ohio State University, 470 Hitchcock Hall, 2070 Neil Avenue, Columbus, OH 43220, USA, Email: [email protected]

9

ABSTRACT

10

Diagrids are known as an aesthetically pleasing and structurally efficient system. The

11

current design codes and provisions, however, provide no specific guidelines for their

12

design under extreme events such as earthquakes. This paper presents a comprehensive

13

investigation of the performance of steel diagrid structures to evaluate their key seismic

14

performance factors. Nonlinear static, time-history dynamic, and incremental dynamic

15

analyses are used to assess diagrid performance and collapse mechanisms in a high

16

seismic region. Seismic performance factors including response modification factor,

17

ductility factor, overstrength factor, and deflection amplification factor are quantified

18

using four different methodologies. Four archetype groups of diagrid buildings ranging

19

in height from 4 to 30 stories have been investigated. An R factor in the range of 4 to

20

5 is recommended for steel diagrid frames in the range of 8 to 30 stories unless

21

supplementary analyses are conducted to find the optimal diagonal angle. For low-rise

22

steel diagrids (under 8 stories) an R factor in the range of 3.5 to 4 is recommended.

23

Further, an overstrength and ductility of 2.5 and 2 is recommended. This paper lays the

24

groundwork for including steel diagrids in design provisions.

25

Keywords: Seismic Performance, Response Modification Factor, Steel structure,

26

Diagrid

27

1. INTRODUCTION

28

Two current trends in design of tall and special buildings are creating freeform signature

29

buildings and using sustainable and efficient structural systems (Wang and Adeli 2014, Rafiei and

30

Adeli 2016). Diagrid, a variation of the tubular structures, enjoys both of those trendy attributes.

31

Diagrids are known as an aesthetically pleasing and structurally efficient system and for their

32

flexibility to create free-form structures. Their inclined diagonal members can carry both gravity

33

and lateral loads (Moon 2007, Mele et al., 2014). Fig. 1 shows the main components of a diagrid

34

frame along with its basic triangular element. Diagrids have been used in a number of signature

35

and free-form high-rise buildings across the world such as the 103-story Guangzhou International

36

Finance Centre, Guangzhou, China, 57-story The Bow, Calgary, Canada, the 51-story Tornado

37

Tower, Doha, Qatar, and the 595.7-m Canton Tower (Moon 2008, Niu et al. 2015). Diagrids have

38

also been used for iconic mid-rise buildings such as the 11-story Seattle Central Library, Seattle,

39

U.S and the 11-story Macquarie Bank, Sydney, Australia (Boake 2014). Further, diagrids have

40

been used for free-form steel space-frame roof structures (Kociecki and Adeli 2013, Asadi and

41

Adeli 2017). However, current codes of practice such as ASCE7-10 (2010) provide no specific

42

design specifications and seismic performance factors for diagrids. Such specifications and factors

43

will make this structural system more widespread for low- to high-rise buildings.

44

The design codes such as ASCE7-10 (2010) permit elastic analysis for the design of different

45

structural systems by providing a response modification factor, R, (ASCE7-10 2010, FEMA 2009

46

and 2012) to account for the nonlinear response of the structure during extreme events (Adeli et

47

al. 1978). Applied Technology Council (ATC 1978) introduced a base shear reduction factor for

48

the computation of the design base shear of a structure using an elastic response spectrum by taking

49

the ductility into account. Early values of the R factor were mostly based on engineering judgment

50

and previous behavior of each structural system during earthquakes (Whittaker et al. 1999).

51

Other design codes also follow this approach and employ performance/behavior factors to

52

account for the nonlinear performance of the structure during earthquakes. The methods to

53

calculate these factors and the effective parameters, however, vary. For instance, Eurocode-8

54

(2004) uses a behavior factor (q) to account for energy dissipation during earthquakes, which is

55

based mostly on ductility and plan and elevation regularity/irregularity of the frame. The Chinese

56

code (GB 50011, 2010) uses a seismic influence coefficient (α1) which is tabulated based on the

57

seismic class and intensity of the site and natural period and damping ratio of the structure.

58

Ductility affects the performance of the structure to dynamic loads and generally reduces the

59

effective base shear (Newmark and Hall 1982). Several architectural and structural factors may

60

cause an amount of overstrength in the building including expected-to-nominal strength ratio of

61

members, detailing of the components and connections in the design process, and non-structural

62

components such as partition walls (Whittaker et al. 1999, FEMA 2009).

63

FEMA (2009) published a comprehensive report on the assessment of building performance

64

and response parameters under seismic loads. The main goal of that report is to set reliable

65

minimum design criteria and provide a consistent approach applicable to building codes when a

66

linear design method is used. The report introduces a procedure to quantify the key structural

67

factors of seismic building structural systems such as period-dependent ductility and overstrength

68

factors. The recommended approach is compatible with previous FEMA reports (FEMA 2000,

69

2005) and ASCE7-10 (2010).

70

The objective of the current research is to evaluate the seismic performance of diagrid

71

structures and propose seismic performance factors (SPFs) including overstrength, ductility,

72

deflection amplification and response modification factors for steel diagrid structures. Nonlinear

73

static, time-history dynamic, and incremental dynamic analyses have been performed to assess the

74

performance of archetype diagrid structures. Key factors affecting diagrid performance are

75

specified. Four different methodologies have been explored to evaluate and quantify SPFs of

76

diagrid archetypes with different heights and diagonal angles: FEMA P-695 (2009), Miranda and

77

Bertero (1994), Vidic et al. (1994), and Newmark and Hall (1982).

78

2.

METHODOLOGY FOR QUANTIFYING SEISMIC PERFORMANCE

79

FACTORS

80

This section describes briefly the four methodologies employed in this research. First, FEMA

81

P-695 (2009) method, the more recent approach, is described in detail. Then, the procedures used

82

to quantify each SPF value is discussed.

83

2.1. FEMA P-695 METHODOLOGY

84

FEMA P-695 report, referred as FEMA (2009) in this article, introduces a comprehensive

85

method to estimate SPFs for new seismic-resisting structural systems. This method integrates

86

uncertainty in demand and performance and employs advanced nonlinear analysis techniques

87

including incremental dynamic analysis (IDA). Fig. 2 shows the main steps of the FEMA (2009)

88

method and the evaluation procedure.

89

The first step is to define a series of criteria for the desired structural system including the

90

structural material, configuration, inelastic and nonlinear properties, and intended scope of

91

application. In the case of diagrids, configuration and particularly the diagonal angle is a key

92

property dictating the performance of the structure. Next, a set of archetypes reflecting a wide

93

range of possible archetype structures should be developed given the scope and criteria defined

94

initially. Archetypes are assembled into a number of performance groups. Given that it is

95

impractical to consider or find the SPFs for all possible applications, the archetypes should

96

represent the typical applications of the system (FEMA, 2009). Using nonlinear static analyses,

97

statistical data on the overstrength, ductility, and median collapse capacities of the structural

98

system should be evaluated. The expressions for quantifying each factor are discussed in the

99

section.

100

2.2. QUANTIFICATION OF SEISMIC RESPONSE FACTORS

101

2.2.1. Response Modification Factor

102

ATC (1995a, b) present a formula for determination of the R factor as a product of three

103

important properties of the structure: redundancy factor (Rr) and period-dependent ductility (Rµ)

104

and overstrength factors (Ro).

105

𝑅𝑅 = 𝑅𝑅𝑜𝑜 𝑅𝑅𝜇𝜇 𝑅𝑅𝑟𝑟

(1)

106

The Ro factor represents the capacity-to-demand strength ratio in a building which is generally

107

larger than 1.0 as there is always some overstrength in the structure. The Rµ factor is associated

108

with the global nonlinear response of the structural system. The Rr factor represents the degree of

109

indeterminacy of the structure or the number of available load carrying lines to transfer seismic

110

loads to the foundation (Whittaker et al. 1999).

111

Eq. 1 has been used for assessment of the R factor for various structural systems such as

112

chevron-braced frames (Kim and Choi 2005), Buckling-Restrained Braced Frames (BRBF)

113

(Asgarian and Shokrgozar 2009), tubular structures in tall buildings (Kim et al. 2009), moment

114

resisting frames with TADAS (triangular-plate added damping and stiffness) dampers (Mahmoudi

115

and Abdi 2012), and steel frames utilizing shape memory alloys (Ghassemieh and Kargarmoakhar

116

2013). Such a study has not been reported for diagrids, however.

117

The redundancy represents an enhanced reliability of the system when multiple vertical lines

118

are used to carry the lateral load. Whittaker et al. (1999) recommend a redundancy factor of

119

approximately 1.0 for structures with at least 4 lines of vertical seismic framing in each

120

perpendicular direction. Since there are at least 4 lateral load-carrying lines (at least 4 diagonals)

121

in each direction in the examples studied in this research, the redundancy factor is assumed to be

122

equal to 1.0.

123

2.2.2. Overstrength Factor

124

The overstrength factor for the structural system is the largest average of all archetype

125

performance groups. FEMA (2009) defines the overstrength factor, Ro, as the ratio of the maximum

126

base shear resistance, Vmax, to the design base shear of the structure, Vd.: 𝑅𝑅𝑜𝑜 =

127

𝑉𝑉𝑚𝑚𝑚𝑚𝑚𝑚 𝑉𝑉𝑑𝑑

(2)

128

where Vmax is based on the nonlinear static pushover curve (Fig. 3) and Vd is the required design

129

base shear defined by ASCE7 (2010).

130

In the literature, other slightly different definitions of this factor have been suggested based on

131

FEMA (2000) idealized pushover curve. FEMA (2000) states that the pushover curve shall be

132

idealized with a bilinear curve using an “iterative graphical procedure” so that the areas above

133

and below the ideal curve are approximately equal as shown in Fig. 3. The secant stiffness (Ke) is

134

taken equal to the slope of the ideal curve where it crosses the primary curve at 0.6 times the

135

effective yield strength, Vy, (Fig. 3). Kim and Choi (2005) use the overstrength factor based on the

136

idealized force-displacement curve introduced in FEMA (2000) as follows: 𝑅𝑅𝑜𝑜 =

137 138

𝑉𝑉𝑦𝑦

𝑉𝑉𝑑𝑑

(3)

The effective yield strength (Vy) shall be equal to or less than the maximum base shear (Vmax

139

in Fig. 3). Eq. 2 results in a larger than or equal value for the overstrength factor than Eq. 3.

140

2.2.3. Ductility Factor

141

The relationship between the period-dependent ductility reduction factor (Rµ) and the ductility

142

ratio (µ) has been studied by several researchers in the past decades (FEMA 2009, Whittaker et al.

143

1999, Miranda and Bertero 1994, Vidic et al. 1994, Newmark and Hall 1982). The relationship

144

depends mostly on the fundamental period of the structure. It changes for displacement, velocity,

145

and acceleration segments of a linear response spectrum (Whittaker et al. 1999).

146

Newmark and Hall (1982) proposed a method to construct the inelastic response spectrum of

147

a structural system from an elastic one which can be used to find the Rµ factor as well. Chopra and

148

Goel (1999) refined the Newmark˗Hall method as follows:

𝑅𝑅𝜇𝜇 =

149

150

where

1 𝑇𝑇 < 𝑇𝑇𝑎𝑎 ⎧ 𝛽𝛽⁄2 𝑇𝑇𝑎𝑎 < 𝑇𝑇 < 𝑇𝑇𝑏𝑏 ⎪(2𝜇𝜇 − 1) 𝑇𝑇

⎨ 𝑇𝑇𝑐𝑐 𝜇𝜇 ⎪ ⎩ 𝜇𝜇

𝑇𝑇𝑏𝑏 < 𝑇𝑇 < 𝑇𝑇𝑐𝑐 𝑇𝑇 > 𝑇𝑇𝑐𝑐

𝛽𝛽 = ln(𝑇𝑇/𝑇𝑇𝑎𝑎 )⁄ln(𝑇𝑇𝑏𝑏 /𝑇𝑇𝑎𝑎 )

151

(4a)

(4b)

152

and T is the natural period of the structure, µ is the ratio of the maximum permissible lateral

153

displacement (δu) to the effective elastic displacement (δy) of the structure, and the period limits

154

are defined based on the elastic response spectra with the following recommended values:

155

Ta=0.030 s, Tb=0.125 s and Tc is the period where the constant acceleration and the constant

156

velocity segments of the inelastic design spectrum meet.

157

Miranda and Bertero (1994) observed that the Rµ˗µ relationship also depends on the site

158

soil condition. Based on a study of 124 ground motions collected on different site conditions they

159

introduced a Φ coefficient to take into account the soil condition as follows: 𝑅𝑅𝜇𝜇 =

160

𝜇𝜇−1 Φ

+ 1 ≥ 1.0

(5)

161

They proposed three different equations (for rock, alluvium, and soft soil sites) for the Φ

162

coefficient based on ductility ratio and period of the structure.

163

Vidic et al. (1994) propose the following equation for the Rµ˗µ relationship: 𝑇𝑇

164 165 166

where

𝑐𝑐1 (𝜇𝜇 − 1)𝑐𝑐𝑅𝑅 + 1 𝑇𝑇 ≤ 𝑇𝑇0 𝑇𝑇0 𝑅𝑅𝜇𝜇 = � 𝑐𝑐𝑅𝑅 𝑐𝑐1 (𝜇𝜇 − 1) + 1 𝑇𝑇 > 𝑇𝑇0 𝑇𝑇0 = 𝑐𝑐2 𝜇𝜇 𝑐𝑐𝑇𝑇 𝑇𝑇𝑐𝑐

(6)

(7)

167

and the coefficients c1, c2, cR, and cT depend on the damping ratio and hysteresis response of the

168

structure. The recommended values for these coefficients used in this research for a bilinear

169

hysteretic behavior (similar to the dashed line in Fig. 3) and 5 percent damping are 1.35, 0.75,

170

0.95, and 0.2, respectively (Chopra and Goel 1999).

171

FEMA (2009), on the other hand, recommends a different approach to find the archetype

172

period-dependent ductility. It requires the lateral load to be applied monotonically until the base

173

shear capacity of 0.8Vmax. Then, the period-dependent ductility factor is obtained by dividing the

174

corresponding lateral roof displacement (δu) by the effective yield lateral roof displacement (δy,eff)

175

(Fig. 3). The effective yield roof displacement is found using the following equation:

176 177

where

𝛿𝛿𝑦𝑦,𝑒𝑒𝑒𝑒𝑒𝑒 = 𝐶𝐶0 𝐶𝐶0 = 𝜑𝜑1,𝑟𝑟

178

𝑉𝑉𝑚𝑚𝑚𝑚𝑚𝑚 𝑊𝑊



𝑔𝑔

4𝜋𝜋2

∑𝑁𝑁 1 𝑚𝑚𝑛𝑛 𝜑𝜑1,𝑛𝑛

2 ∑𝑁𝑁 1 𝑚𝑚𝑛𝑛 𝜑𝜑1,𝑛𝑛

� (𝑇𝑇𝑝𝑝 ) 2

(8)

(9)

179

and W, g, and Tp are building weight, gravity acceleration, and the maximum permissible

180

fundamental period of the structure according to ASCE7-10 (2010). The fundamental period of the

181

structure can be computed based on an eigenvalue analysis but shall not be greater than CuTa (the

182

product of the coefficient for the upper limit and the approximate fundamental period). The

183

modification factor C0 converts the spectral displacement of the equivalent SDOF system to the

184

roof displacement of the multi-degree of freedom (MDOF) structure and is found by Eq. 9 which

185

is Eq. C3-4 of ASCE/SEI 41-06 (2006) or alternatively using the values from Table 3-2 of FEMA

186

(2000). In Eq. 9, mn, φ1,n, φ1,r are the mass at level n, the ordinate of fundamental mode shape at

187

level n, and the roof, respectively.

188

2.2.4. Deflection Amplification Factor

189

The ASCE7-10 (2010) uses the deflection amplification factor (Cd) to determine the amplified

190

story deflection at level x (δx) from an elastic analysis. The Cd factor can be calculated using the

191

structure ductility ratio (µ), the effective yield strength (Vy), and the design base shear (Vd) as

192

follows (Uang and Maarouf 1994):

193

𝐶𝐶𝑑𝑑 =

𝑉𝑉𝑦𝑦

𝑉𝑉𝑑𝑑

𝜇𝜇

(10)

194 195

FEMA (2009) considers the Cd factor as a reduced R factor and recommends the following equation to calculate the Cd: 𝐶𝐶𝑑𝑑 =

196

𝑅𝑅

𝐵𝐵𝐼𝐼

(11)

197

where the BI is a numerical coefficient provided in Table 18.6-1 of the ASCE7-10 (2010) in terms

198

of the inherent damping ratio of the structure. The BI value for 5 percent effective damping ratio

199

is 1.0 where the period of the structure is larger than T0 = 0.2SD1/SDS. This means that in this case

200

the Cd factor is equal to the R factor.

201

2.2.5. Relation Between Ductility Factor (Rµ) and Ductility Ratio (µ)

202

The ductility factor (Rµ) is calculated using three methods: Newmark˗Hall (NH), Miranda-

203

Bertero (MB), and Vidic-Fajfar-Fischinger (VFF). These methods are selected to cover a

204

reasonably wide range of methodologies proposed for quantifying Rµ. The Newmark and Hall

205

(1982) methodology paved the way for ATC method (1995a&b) and is used by a number of

206

previous researchers (Kim and Choi 2005, Kim et al. 2009). The MB method includes the effect

207

of soil property and the VFF method considers hysteresis response and damping ratio of the

208

system. By considering these three methods in addition to FEMA (2009) method, the authors aim

209

to obtain more reliable values for the Rµ and R factors.

210

Fig. 4 shows the variation of Rµ versus the period of the structure for three different ductility

211

ratios of 2, 4, and 6 using the three aforementioned approaches. In general, the VFF approach

212

offers an upper bound for the Rµ factor in periods larger than Tb whereas the refined NH approach

213

is the lower bound in that range. The MB approach for rock soils generally yields Rµ values

214

between the other two approaches. Also, this last approach results in larger Rµ values than the NH

215

approach for periods between 1 to 3 seconds but not as large as the VFF approach. For periods

216

larger than 3 seconds, all three methods result in virtually a constant value of Rµ (equal to µ) where

217

the VFF approach yields a relatively larger value than the others. In case of diagrids, the

218

fundamental period of the structure is relatively low due to their substantial lateral stiffness (Kim

219

and Lee 2012, Asadi and Adeli 2017). Therefore, low- to mid-rise diagrids are expected to fall in

220

the range of small periods (lower than 2.0s). More information on Rµ-µ relationship is presented

221

in Chopra and Goel (1999), Whittaker et al. (1999), and ATC (1995a&b).

222 223

3. ARCHETYPE DIAGRID STRUCTURES 3.1. ARCHETYPE BUILDINGS

224

Four groups of archetype steel diagrids with 4, 8, 15, and 30 stories are considered for

225

assessment of SPFs to cover a wide range of possible applications of diagrids. As is common in

226

diagrid structures, the diagrid frames form the perimeter of the building (Ali and Moon, 2007).

227

The archetypes are office buildings located in Los Angeles, CA with Ss (spectral response

228

acceleration at 0.2 sec) and S1 (spectral response acceleration at 1 sec.) of 1.803g and 0.649g,

229

respectively. Dead and Live loads are 4 and 2.4 kN/m2, respectively. The floor plan for the 4-, 8-

230

and 15-story groups is similar as presented in Fig. 5a. Fig. 5b presents the typical floor plan for

231

the 30-story group. For each group, three diagrid patterns with diagonal angles of approximately

232

45°, 63°, and 72° with the horizon are studied to account for various possible diagonal

233

configurations. Fig. 6 shows the diagrid patterns used in this research. The structures are labeled

234

by using the number of stories and their diagonal angle. For instance, archetype 15-63 refers to a

235

15-story diagrid structure with a diagonal angle of 63°.

236

3.2. DESIGN AND ANALYSIS CRITERIA

237

AISC Load and Resistance Factor Design (LRFD) (AISC 2011), AISC 360-10 (2010), and

238

ASCE7-10 (2010) are used for the structural design of all archetypes. Note that ASCE7-10 (2010)

239

does not provide any specific performance factor for the seismic design of diagrids. For

240

preliminary design, following previous studies (Kim and Lee 2010&2012; Kwon and Kim 2014),

241

all three seismic coefficients including response modification, overstrength, and deflection

242

amplification factors are assumed to be equal to 3.0. The A992 grade 50 steel with yield and

243

ultimate strength of 345 and 450 MPa, respectively, is used for all steel members. The standard W

244

section is used for diagonals, beams, and interior columns. Diagonals are designed to carry both

245

lateral and gravity loads. For wind loads, Exposure Category C and wind speed of 110 mph are

246

used based on the location of the structures. Floors are reinforced concrete slabs with a thickness

247

of 6 in. The ASCE7 (2010) requirements for story drift are satisfied.

248

Three types of analyses are performed for SPF evaluation including three-dimensional

249

nonlinear static analysis using SAP2000 (CSI, 2011) per FEMA (2005; 2009) and NTHA and IDA

250

using OpenSees planar models (Mazzoni et al., 2006) models per FEMA (2009; 2012). SAP2000

251

has been used by a number of other diagrid system researchers in recent years in a similar fashion

252

(Moon et al., 2007; Kim et al., 2010&2012; Mele et al., 2014). The plastic performance and

253

modeling criteria of FEMA (2005) and ASCE/SEI 41-13 (2014) for braced frames are adapted for

254

diagonals. Geometric nonlinearity (P-∆ effect) is considered directly in the computation of the

255

stiffness matrix. Fig. 7 depicts the force-deformation curves used for modeling plastic hinges in

256

SAP2000 models. The modeling parameters a, b, c in Fig. 7 are calculated per FEMA (2005)

257

Tables 5-6 and 5-7. The parameter ∆c represents the axial deformation at expected buckling load

258

(Pcr).

259

For OpenSees models, the hysteretic model of Menegotto-Pinto with fiber element and 0.02

260

hardening is used for both diagonals and beams (Mazzoni et al., 2006). The method developed by

261

Uriz (2005) for modeling Concentrically Braced Frames (CBFs) in OpenSees which considers low

262

cycle fatigue and global brace buckling is adapted to model nonlinear behavior of diagonals. To

263

simulate P-∆ effect, a leaning column linked to the main frame is considered (Moghaddasi and

264

Zhang, 2013). Fig. 7 also depicts the key parameters of the OpenSees models. The nonlinear

265

dynamic analyses are conducted for 4- and 8-story archetypes.

266

The few experimental studies published on diagrid connections (Kim et al., 2010 and 2011)

267

provide little information on design and modeling of diagrid connection. Hence, connections are

268

not explicitly modeled in this research. Different possible approaches were tested and assuming

269

moment-resisting connections seem to provide the most accurate results. Note that regardless of

270

the connection type, i.e. hinged or moment-resisting, the diagonal design and behavior are

271

governed by axial strength not flexural strength (Moon et al., 2007; Kim and Lee, 2012; Mele et

272

al., 2014).

273

4. NONLINEAR PERFORMANCE OF STEEL DIAGRIDS

274

Nonlinear static analysis, NTHA, and IDA are performed per FEMA (2005, 2009, 2012a,

275

2012b) on archetype diagrid structures to assess their seismic performance and evaluate the SPFs.

276

This section summarizes key findings of the static and dynamic performance of diagrids and

277

clarifies details of the analyses used for SPF assessment.

278

4.1. NONLINEAR STATIC ANALYSIS

279

In static nonlinear analyses, three lateral load distributions are considered for each model: 1)

280

uniform distribution, 2) the distribution provided by the Equivalent Lateral Force (ELF) method

281

of ASCE7-10 (2010), and 3) the modal shape distribution, and the critical one, showing the least

282

lateral stiffness and load capacity, is chosen for quantification of the SPFs.

283

Figs. 8a-d show the lateral force versus roof displacement, the pushover curve, obtained by a

284

static nonlinear analysis for the 4-, 8-, 15-, and 30-story models, respectively. Diagrids show large

285

initial lateral stiffness and collapse capacity which is consistent with previous studies (Moon et al.,

286

2007; Kim and Lee, 2012; Milana et al., 2015). Plastic hinges are well spread across the diagrid

287

frames for most archetypes except the 4-72 and 8-72. These two archetypes have incomplete

288

uppermost diagrid modules (shown in Fig. 9) which adversely impact their behavior. The optimal

289

archetype in terms of nonlinear behavior and lateral stiffness is found to be the 4-63, 8-63, 15-72,

290

and 30-72 models among the 4-, 8-, 15-, 30-story structures, respectively. In these optimal models,

291

plastic hinges are spread both horizontally and vertically across the width and height of the

292

structure more broadly than the other case; these models have a larger load carrying capacity

293

compared with other models (Fig. 8).

294

4.2. NONLINEAR TIME-HISTORY ANALYSIS

295

NTHA is conducted on OpenSees models of 4- and 8-story archetype buildings considering

296

the gravity loads and a set of 22 far-field ground motion records recommended for SPF assessment

297

in Appendix A of FEMA (2009).

298

4.2.1. Earthquake Ground Motions

299

A representative set of ground motions is a critical component of a reliable seismic

300

performance assessment. FEMA (2012a) recommends a minimum of 11 ground motion records

301

for collapse analysis of building structures. In this research, a set of 22 far-field records

302

recommended by FEMA (2009) to appropriately represent record-to-record variability is used in

303

NTHAs and IDAs. The records obtained from 14 different events include site class C and D and

304

magnitudes in the range of 6.5 to 7.6. Based on FEMA (2009) instructions, they are normalized

305

with respect to peak ground velocity (PGV) and scaled to match the design response spectrum of

306

ASCE7-10 (2010) at the fundamental period of the structure. Fig. 10 depicts the scaled response

307

spectrum alongside the design response spectrum for the 8-45 archetype.

308

4.2.2. Diagrid Performance under Nonlinear Dynamic Analysis

309

The nonlinear dynamic performance of diagrid archetypes is studied under two earthquake

310

hazard intensities: DBE (10% probability of exceedance in 50 years) and MCE (2% probability of

311

exceedance in 50 years) per United States Geological Survey (USGS) hazard maps. The NTHAs

312

are performed in OpenSees for 4- and 8-story archetypes. Table 1 summarizes the key engineering

313

demand parameters (EDPs) of the archetypes studied, including the maximum and mean inter-

314

story drift (IDRmax and IDRavg, respectively) under DBE and MCE.

315

Diagrids shows relatively small IDRmax and IDRavg under both DBE and MCE compared to

316

other structural systems (on average, 1.26% and 0.64% for DBE and 2.02% and 0.96% for MCE).

317

For comparison, Chen et al. (2008) report an IDRmax of 1.46% and 2.78% under DBE and MCE

318

for a 3-story steel CBFs located in downtown Los Angeles, CA. As noted under static analysis,

319

the incomplete uppermost module in 4-72 and 8-72 archetypes causes a substantially larger IDR

320

in these cases. Table 1 also shows the IDRmax to IDRavg ratio which is an indicator of the soft-story

321

vulnerability of the structure. Large IDRmax/ IDRavg values indicate concentration of damage in a

322

specific story and likely soft-story formation in the structure. The IDRmax/IDRavg of diagrids is

323

close to CBFs, 1.84 and 2.00 for diagrids compared to 1.76 and 2.08 for the 3-story CBFs under

324

DBE and MCE, respectively (Chen et al., 2008). Moreover, if cases with 72° diagonal angle are

325

excluded, diagrids are much less likely to form soft-story than CBFs. These cases have an

326

incomplete uppermost module. Fig. 11 and 12 depict the variation and the logarithmic trendline of

327

IDRmax, IDRavg, and their ratio for different models and hazard levels. The vertical axis shows the

328

pseudo spectral displacement based on 5% damped design spectra of the site at the fundamental

329

period of the structure, Sd (T1,5%). Accordingly, the IDRmax values and IDRmax to IDRavg ratio for

330

diagrid with 72° diagonal angle has much more dispersion (i.e. standard deviation) than other cases

331

in addition to larger values indicating more uncertainty in the behavior of these models. For

332

instance, the dispersion for IDRmax to IDRavg ratio for 4-72 archetype under DBE is 0.39 compared

333

to 0.18 and 0.05 for 4-45 and 4-63 archetypes, respectively. Further, the trendlines for the 72°

334

archetype in Figs. 11 and 12 has a much larger slope than that of 63° and 45° archetypes for all

335

EDPs. This indicates that the IDRmax and IDRavg increase at a higher rate in 72° models compared

336

to others with the increase of spectral displacement. On the other hand, the trendlines for 63° and

337

45° models are close to each other. The 4-63 archetype shows a slightly higher rate than 4-45

338

archetype (Fig. 11). While the 8-45 archetype shows a considerably higher rate than 8-63 archetype

339

(Fig. 12). Generally, diagrid archetypes absorb large spectral acceleration under both DBE and

340

MCE earthquakes which implies a large capacity and stiffness for diagrid frames. This will

341

manifest in larger overstrength factor for diagrids compared to similar structural systems namely

342

CBFs.

343

4.3. INCREMENTAL DYNAMIC ANALYSIS

344

The IDA is used to explicitly consider record-to-record uncertainty in collapse evaluation

345

(FEMA, 2012a; Vamvatsikos and Cornell, 2002). The IDA includes hundreds of time-history

346

analyses where the ground motion intensity is increased gradually to achieve collapse in the

347

structure. Fig. 13 shows IDA curves for the 4-45 diagrid archetype. The vertical axis shows the

348

spectral acceleration based on 5% damped design spectra of the site at the fundamental period of

349

the structure, Sa (T1,5%). For each archetype, 748 NTHAs are performed to develop the

350

corresponding collapse fragility curve. The IDA is conducted for 4- and 8-story archetypes.

351

Collapse is achieved if an insignificant increase in ground motion intensity (spectral acceleration)

352

result in a significant increase in the governing EDP (maximum IDR) or a dynamic instability

353

happens (FEMA, 2009; Yamin et al, 2017).

354

4.4. COLLAPSE FRAGILITY ASSESSMENT

355

For 4- and 8-story archetypes, collapse fragility functions for each archetype were developed

356

in terms of cumulative distribution function (CDF) of ground motion intensities leading to

357

collapse. According to FEMA (2009), adjusted collapse margin ratio (ACMR) is defined as the

358

ratio of median collapse capacity (ŜCT) to the MCE intensity (SMT) multiplied by Spectral Shape

359

Factor (SSF):

360

𝐴𝐴𝐴𝐴𝐴𝐴𝐴𝐴 = 𝑆𝑆𝑆𝑆𝑆𝑆 × Ŝ𝐶𝐶𝐶𝐶 /𝑆𝑆𝑀𝑀𝑀𝑀

(12)

361

SSF values are provided in Table 7-1 of FEMA (2009) based on ductility ratio and fundamental

362

period of the structure. Also, the acceptable values of ACMR are provided in Table 7-3 of FEMA

363

(2009) based on total system collapse uncertainty.

364

The collapse capacity, ŜCT, obtained from IDA for each ground motion record is used to

365

evaluate the probability of collapse at a certain Sa (T1,5%). Then, a lognormal distribution function

366

is used to estimate the collapse fragility function for each archetype. The empirical CDF and the

367

fitted lognormal collapse curve are illustrated in Fig. 14 for 4- and 8-story archetypes. The Sa

368

(T1,5%) associated with DBE and MCE are shown with dashed lines in Fig. 14.

369

Table 2 lists ŜCT, collapse IDRmax, and their corresponding lognormal dispersion (𝛽𝛽𝑆𝑆𝐶𝐶𝐶𝐶 and 𝛽𝛽𝐼𝐼𝐼𝐼𝐼𝐼

370

respectively), as well as ACMR and probability of collapse for 4- and 8-story archetypes. The mean

371

ACMR is 2.05 which is higher than the acceptable value, i.e. 1.96, and individual cases has a higher

372

ACMR than individual ACMR limit, i.e. 1.56. The acceptable ACMR margins are evaluated for a

373

good model quality conditions based on Table 7-3 of FEMA (2009). The probability of collapse

374

under MCE for each individual archetype is less than 20%, the acceptance limit suggested by

375

FEMA (2009). The mean probability of collapse under MCE, however, is 13.6% which is higher

376

than the suggested acceptance limit, i.e. 10%. To achieve the suggested acceptance limit,

377

archetypes were redesigned several times with different approaches. The design options which

378

passes the later acceptance limit has an extremely small demand to capacity ratio (Fu /Fn) for all or

379

many structural elements and as a result, are economically inefficient and impractical. Note that

380

per ASCE and AISC design codes, the archetypes need to be designed for DBE not MCE. Thus,

381

given that the archetypes listed in Table 2 meet ACMR requirements, they are accepted for collapse

382

fragility assessment.

383

5. SEISMIC PERFORMANCE FACTORS FOR STEEL DIAGRIDS

384

The effective yield strength (Vy) and effective elastic displacement as well as the maximum

385

permissible lateral displacement (δu) are found using the idealized bilinear pushover curve

386

introduced in FEMA (2000) (Fig. 3). Table 3 presents the seismic response parameters including

387

the effective yield strength (Vy), ductility ratio (µ), deflection amplification factor (Cd), and

388

overstrength factor (Ro), period-dependent ductility factor (Rµ), and response modification factor

389

(R) found using four different methods discussed in the previous section. Table 4 presents the

390

mean, standard deviation (SD), maximum (Max), and minimum (Min) values for the seismic

391

response parameters for models investigated in this research.

392

5.1. DUCTILITY RATIO

393

Fig. 15 presents a bar chart for the ductility ratio (µ) of archetypes studied defined as the ratio

394

of the ultimate lateral displacement (δu) to the effective elastic displacement (δy) based on the

395

idealized bilinear nonlinear static pushover curve (Fig. 3). The mean and the SD values of ductility

396

ratio, as reported in Table 4, are 2.65 and 0.79, respectively. The largest ductility ratio in the 4-

397

and 8-story archetypes belongs to 4-63 and 8-63, respectively while in 15- and 30-story archetypes

398

the 72° archetypes show a considerably larger ductility than others. This result indicates that the

399

diagonal angle has a major effect on the ductility of the diagrid structures and by choosing an

400

optimal diagonal angel, the ductility of diagrids can be improved noticeably.

401

5.2. OVERSTRENGTH FACTOR

402

The overstrength factor (Ro) is evaluated using Eqs. 2 and 3. The results are presented in Fig.

403

15. As expected, the FEMA (2009) equation yields a larger value for the Ro factor than Eq. 3 used

404

by Kim and Choi (2005) by an average of 27%. In 4-, 8- and 30-story archetypes, the 63° case has

405

the largest overstrength whereas the overstrength of 15-story cases are relatively similar. This

406

difference is mostly due to the section grouping in the design process and the capacity-to-demand

407

ratio of diagonal sections in the 63° archetypes. Note that the architectural and material factors

408

causing overstrength are similar in all cases.

409

The average value of the overstrength factor for all diagrid archetypes is 2.89 and 2.28 based

410

on Eqs. 2 and 3, respectively. This is relatively close to that of steel moment-resisting frames

411

(MRFs) which is equal to 3.0 per ASCE7-10 (2010), and noticeably larger than the overstrength

412

factors of CBFs and eccentrically braced frames (EBFs) which are both equal to 2.0 per ASCE7-

413

10 (2010). This points to a notably large reserve strength for steel diagrid frames.

414

5.3. DUCTILITY FACTOR

415

Four different approaches, NH, MB, VFF, and FEMA (2009), were used to calculate the

416

ductility factor (Rµ). Fig. 16 shows the variation of the ductility factor for four groups of diagrid

417

structures and three diagonal angles. In general, the ductility factor calculated based on the VFF

418

and MB approaches are larger than the others with the VFF approach being the largest. The result

419

from the NH and FEMA (2009) approaches are relatively close except in the 30-63 archetype,

420

even though the corresponding equations are completely different. The mean ductility factor based

421

on the FEMA (2009) approach is 11, 21, and 28 percent smaller than that of the NH, MB, and VFF

422

approaches, respectively.

423

The mean ductility factors for 4-, 8-, 15-, and 30-story archetypes are relatively close indicating

424

that the number of stories does not have a significant effect on the ductility factor. The diagonal

425

angle, however, has a major effect on the ductility factor similar to the ductility ratio. The

426

archetypes with the largest lateral stiffness in each group, 4-63, 8-63, 15-72, and 30-72, show a

427

noticeably larger ductility factor than others in all approaches studied. The 72° archetypes are

428

found to have a larger ductility factor than others unless the uppermost diagrid module is

429

incomplete. Clearly, the uppermost incomplete diagrid module in 4-72 and 8-72 archetypes

430

adversely affects their ductility factors.

431

The bar chart in Fig. 17 compares the mean SPFs (Ro, Rµ, and R) obtained using various

432

approaches. The SD is also shown in the middle of each bar. In case of Rµ, the SD value for VFF

433

approach is the largest showing undesirable large variations of calculated values using this method.

434

At the same time, the Rµ values calculated based on the NH approach are less disperse showing

435

the smallest SD among all four approaches.

436

5.4. RESPONSE MODIFICATION FACTOR

437

The response modification factor is found for all archetypes using the four approaches

438

discussed earlier. The results are presented in Fig. 18 and Tables 3 and 4. In most cases, the NH

439

approach yields the smallest and most conservative R factor than others except for the 30-63 and

440

all 4-story archetypes. For 30-63 and 4-story archetypes, the FEMA (2009) approach yields the

441

smallest R factor because of the small Rµ factor of these archetypes. Note that the FEMA (2009)

442

approach for finding the period-dependent Rµ factor is different from other approaches. Its

443

equation depends on the period and weight of the structure. In the case of the 30-63 archetype, the

444

period of the structure is relatively large (1.26 seconds, a 105-meter high diagrid) but the weight

445

of this archetype is the smallest among the 30-story cases. This leads to a large effective yield roof

446

displacement (δy,eff) and consequently smaller Rµ (Eq. 8). On average, NH approach gives an R

447

factor of 5.06 with the SD of 1.39 which are both the smallest values among all approaches (Fig.

448

17). This shows that the NH method yields the most conservative and the least disperse results.

449

The MB approach for rock soil yields a mean R factor of 5.67 which is close to the FEMA (2009)

450

mean value of 5.60 but smaller than that of 6.21 obtained using the VFF. Generally, the VFF

451

approach shows the largest R factor (up to 10.76) which can be considered as an upper bound for

452

the R factor of steel diagrid structures (Table 3).

453

In general, four parameters affect the SPFs and in particular, the R factor of diagrid structures.

454

Diagonal angle has the largest influence. As mentioned earlier, the 4-63, 8-63, 15-72, and 30-72

455

archetypes are the optimal archetypes corresponding to each group in terms of nonlinear behavior

456

and lateral stiffness. They have the largest value of the R factor in their corresponding group as

457

well. This indicates that an optimal diagonal angle can increase the R factor of the diagrid steel

458

structure substantially, up to 61 percent in the case of the FEMA (2009) approach. In order to

459

benefit from a large R factor in the range 6-8 (based on the mean value of optimal cases for four

460

approaches), the designer needs to find the optimal diagonal angle based on aspect ratio, structural

461

configuration, effective loads, etc. This can be achieved by checking multiple diagonal

462

configurations or more effectively through a formal optimization method (). In the absence of an

463

extensive parametric study or a formal optimization approach, a smaller conservative R factor

464

between 4-5 (based on the mean value of non-optimal cases for four approaches) is recommended.

465

The number of stories or the height of the structure also affects the diagrid R factor. Low-rise

466

cases (4-story archetypes) show a noticeably smaller R factor than other cases; an average of 3.8

467

compared to overall average of 5.64. Since diagrids are most effective against large lateral loads,

468

a smaller R factor between 3.5-4 is recommended for low-rise buildings (under 8-story). This value

469

is based on mean R factor of 4-story archetypes for four approaches. The mean value of the R

470

factor increases with an increase in the number of stories except for the FEMA (2009) approach

471

where the mean value for the 30-story archetypes is smaller than those of 8- and 15-story

472

archetypes. Similarly, the aspect ratio of the building also influences the R value. The low-rise

473

buildings with smaller aspect ratio have a noticeably smaller R factor.

474

Another key influencing parameter is the configuration and in particular the incomplete

475

uppermost diagrid module. As shown in Fig. 9, the 4-72 and 8-72 have an incomplete uppermost

476

diagrid module which adversely affects their performance and causes a reduction in the R factor.

477

The structural deformation increases in these incomplete modules initiating failure of diagonals.

478

This adverse impact is clearer in the 8-72 archetype where its R factor is noticeably lower than 8-

479

63 archetype. Consequently, if the designer wants to have an incomplete upper module in the

480

diagrid structure, the R factor needs to be reduced accordingly. The magnitude of this reduction

481

should be evaluated by supplementary analyses per FEMA (2009).

482

5.5. DEFLECTION AMPLIFICATION FACTOR

483

The results for the deflection amplification factor (Cd) using Eqs. 10 and 11 are presented in

484

Tables 3 and 4 and as a bar chart in Fig. 15. The result from each equation is noticeably different

485

for different archetypes but the mean values are relatively close. The mean value for the Cd factor

486

using Eq. 10 and Eq. 11 is 6.03 and 5.60, respectively. Note that the average of results from Eq.

487

13 (6.03) is larger than the overall mean R factor obtained (5.64). The mean values for the Cd factor

488

are larger than those of steel MRFs which are in the range 3.0-5.5 per ASCE7-10 (2010), and CBFs

489

which are in the range 3.25-5.00 per ASCE7-10 (2010).

490

6. CONCLUSIONS

491

This paper presented a comprehensive study of the key seismic performance factors needed

492

for the seismic design of diagrids including ductility ratio, deflection amplification factor, ductility

493

factor, overstrength factor, and the response modification factor. Four different methodologies

494

were employed: Newmark˗Hall, Miranda-Bertero, Vidic-Fajfar-Fischinger, and FEMA P-695.

495

Four archetype groups of diagrids ranging in height from 4 to 30 stories were studied in a high

496

seismic region.

497

The mean value of R factor based on four methods and twelve structural archetypes (a total of

498

48 cases) is 5.64. This value is relatively large given that no special seismic design consideration

499

is included in the modeling. Experimental studies aiming to develop special seismic considerations

500

for design of diagrid connections and diagonal members will improve the performance of steel

501

diagrids. For comparison, steel concentrically braced frames (CBFs) has an R factor of 3.25 for

502

ordinary CBFs to 6.00 for special CBFs per ASCE7-10. The optimal archetypes in terms of

503

nonlinear behavior and lateral stiffness in each group (4-63, 8-63, 15-72, and 30-72 archetypes)

504

have a disproportionately large effect on the overall mean seismic response factor of steel diagrid

505

structures. The mean R factor for all archetypes excluding those four is 4.76.

506

In general, four parameters affect the seismic performance factors of diagrid structures: 1)

507

diagonal angle, 2) number of story, 3) height to width ratio (aspect ratio) of the building, and 4)

508

having an incomplete upper diagrid module. Diagonal angle is the most effective parameter and

509

an optimal diagonal angle can significantly improve the ductility and seismic performance of the

510

diagrid structure. An R factor in the range of 4 to 5 is recommended for steel diagrid frames in the

511

range of 8 to 30 stories unless supplementary analyses are conducted to find the optimal diagonal

512

angle. For low-rise steel diagrids (under 8 stories) an R factor in the range of 3.5 to 4 is

513

recommended. Further, an overstrength and ductility of 2.5 and 2 is recommended based on the

514

mean values for all archetypes excluding the optimal ones. The deflection amplification factor

515

needs to be calculated based on the R factor and in most cases, it can be taken as equal to the R

516

factor. This paper lays the groundwork for including steel diagrids design provisions in ASCE and

517

AISC standards. The seismic overstrength and response modification factors of steel diagrids are

518

found to be larger than the concentrically braced frames, particularly when an optimal diagonal

519

angle is used, thus making them a superior alternative structural system.

520

FUTURE RESEARCH

521

The fundamental period of diagrids is notably smaller than conventional tubular systems (Kim

522

and Lee 2012), Moment-Resisting Frames (MRFs), and Concentrically Braced Frames (CBFs).

523

The current ASCE7-10 (2010) equation for approximate fundamental period is Ta = Ct hnx where

524

of Ct and x depend on the type of structure and h is the structure height. For diagrids, using the Ct

525

and x values of 0.0488 and 0.75 (for “other structural systems”) the equation generally yields a

526

larger period than direct modal analysis which may lead to a non-conservative design. Therefore,

527

new equations for the fundamental period similar to those developed for MRF (Adeli 1985, Young

528

and Adeli 2014), CBF (Young and Adeli 2014), and EBF (Young and Adeli 2016) should be

529

developed for diagrids to reflect the diagrid characteristics more accurately.

530

A conclusion of this research is the diagonal angle plays a key role in the structural

531

performance of diagrids. The optimal diagonal angle can change based on the aspect ratio,

532

structural configuration, effective loads, etc. As such, finding the optimal angle is a challenging

533

problem. Additional research is needed on the application of optimization techniques for the most

534

efficient design of diagrid systems. Authors advocate the use of nature-inspired computing

535

techniques (Siddique and Adeli, 2017) such as evolutionary computing (Wright and Jordanov,

536

2017; Pillon et al., 2016; Siddique and Adeli, 2013) or neural dynamics model of Adeli and Park

537

(Park and Adeli, 1995; Tashakori and Adeli, 2002) that have been used effectively for both

538

minimum weight and cost optimization of highrise and superhighrise building structures with

539

thousands of members (Adeli and Park 1998; Aldwaik and Adeli, 2014).

540

In addition to introduction of innovative structural systems for highrise building structures,

541

two key technologies at the frontiers of structural engineering research have been health

542

monitoring of structures (Shan et al., 2016; Tsogka et al., 2017), and active, semi-active, and hybrid

543

vibration control of structures under dynamic earthquake and wind loading where significant

544

advances have been made in recent years (Kim and Adeli, 2005a&b; Karami and Akbarabadi,

545

2016). Application of these technologies can lead to development of smart/adaptive diagrid

546

systems where data collected by sensors are processed using advanced signal processing

547

techniques (Amezquita-Sanchez and Adeli, 2016) and machine learning approaches (Palomo and

548

Lopez-Rubio, 2016; Lin et al., 2017; Zhang et al., 2017) to monitor their health in real-time, and

549

actuators or tuned liquid column dampers are used to modify their behavior, reduce their

550

vibrations, and lessen the impact of extreme dynamic loading.

551 552 553 554 555 556 557 558 559 560 561

REFERENCES Adeli H., 1985. Approximate formulae for period of vibrations of building systems, Civ Eng Prac and Des Eng 4 (1), 93–128. Adeli, H., Gere, J.M., Weaver W., 1978. Algorithms for nonlinear structural dynamics. ASCE J Struct Div 104 (2), 263-280. AISC, 2011. Steel Construction Manual 14th ed. Load and resistance factor design specification for structural steel buildings, American Institute of Steel Construction, Chicago, IL. AISC, 2010. ANSI/AISC 360-10: An American National Standard – Specification for Structural Steel Building, American Institute of Steel Construction. Chicago, Illinois. Ali M.M., Moon K.S. 2007. Structural Developments in Tall Buildings: Current Trends and Future Prospects. Architectural Science Review 50(3): 205–223.

562

Amezquita-Sanchez, J.P. and H. Adeli, H. (2016), “Signal Processing Techniques for Vibration-based

563

Health Monitoring of Structures,” Archives of Computational Methods in Engineering, 23:1, pp. 1-15

564

(DOI: 10.1007/s11831-014-9135-7).

565 566 567 568 569 570 571 572 573 574 575 576

Asadi, E., and Adeli, H. 2017. Diagrid: An Innovative, Sustainable and Efficient Structural System, The Structural Design of Tall and Special Buildings, 26(8), DOI 10.1002/tal.1358. ASCE, 2006. Seismic Rehabilitation of Existing Buildings. ASCE Standard ASCE/SEI 41-06, American Society of Civil Engineers, Reston, Virginia. ASCE, 2010. Minimum design loads for buildings and other structures. SEI/ASCE Standard No. 7–10, American Society of Civil Engineers, Reston, Virginia. ASCE (American Society of Civil Engineers). (2014). Seismic Evaluation and Retrofit of Existing Buildings: ASCE Standard ASCE/SEI 41-13. Asgarian B., Shokrgozar, H.R., 2009. BRBF response modification factor, J Constr Steel Res 65 (2), 290298. ATC, 1978. Tentative provisions for the development of seismic regulations for buildings. ATC-3-06, Applied Technology Council, Redwood City, California 45–53.

577 578 579 580 581 582 583 584 585 586 587 588

ATC, 1995a. Structural response modification factors. ATC-19, Applied Technology Council, Redwood City, California 5–32. ATC, 1995b. A critical review of current approaches to earthquake resistant design. ATC-34, Applied Technology Council, Redwood City, California 31–36. Boake, T.M., 2014.

Diagrid structures: systems, connections, details, Birkhäuser, Switzerland,

. Chopra, A.K., Goel, R.K., 1999. Capacity-demand-diagram methods based on inelastic design spectrum. Earthquake Spectra 15 (4), 637-656. CSI (Computers and Structures, Inc.). 2011. CSI Analysis Reference Manual for SAP2000, ETABS, SAFE, and CSiBridge, Berkeley, California, USA. European Committee for Standardization, 2004. Eurocode 8: Design of structures for earthquake resistance-part 1: general rules, seismic actions and rules for buildings. EN 1998-1:2004, Brussels.

589

FEMA (Federal Emergency Management Agency). 2000. FEMA-356: Prestandard and commentary for

590

the seismic rehabilitation of buildings, Building Seismic Safety Council for The Federal Emergency

591

Management Agency, Washington, D.C.

592

FEMA (Federal Emergency Management Agency). 2005. FEMA-440: Improvement of nonlinear static

593

seismic analysis procedures, Building Seismic Safety Council for The Federal Emergency

594

Management Agency, Washington, D.C.

595

FEMA (Federal Emergency Management Agency). 2009. FEMA P-695: Quantification of building seismic

596

performance factors, Building Seismic Safety Council for The Federal Emergency Management

597

Agency, Washington, D.C.

598 599

FEMA (Federal Emergency Management Agency). 2012a. “Seismic performance assessment of buildings.” FEMA P-58, The Federal Emergency Management Agency Washington, DC.

600

FEMA (Federal Emergency Management Agency). 2012b. FEMA P-751: 2009 NEHRP recommended

601

seismic provisions: design examples, Building Seismic Safety Council for The Federal Emergency

602

Management Agency, Washington, D.C.

603 604 605 606

Ghassemieh, M., Kargarmoakhar, R., 2013. Response modification factor of steel frames utilizing shape memory alloys, J Intell Mater Syst Struct. 24 (10), 1213-1225. Kim, H. and Adeli, H. (2005a), "Hybrid Control of Smart Structures Using a Novel Wavelet-Based Algorithm", Computer-Aided Civil and Infrastructure Engineering, Vol. 20, No. 1, pp. 7-22.

607

Kim, H. and Adeli, H. (2005b), "Wind-Induced Motion Control of 76-Story Benchmark Building Using the

608

Hybrid Damper-Tuned Liquid Column Damper System”, Journal of Structural Engineering, ASCE,

609

Vol. 131, No. 12, pp.1794-1802.

610

Kim, J., Choi, H., 2005. Response modification factors of chevron-braced frames, Eng Struct 27, 285-300.

611

Kim J., Lee Y.H. 2010. Progressive collapse resisting capacity of tube-type structures. The Structural

612 613 614 615 616 617 618

Design of Tall and Special Buildings 19: 761–777. Kim, J., Lee, Y.H, 2012. Seismic performance evaluation of diagrid system buildings, Struct Des Tall Spec Build 21 (10), 736-749. Kim, J., Park, J., Shin, S., Min, K., 2009. Seismic performance of tubular structures with buckling restrained braces, Struct Des Tall Spec Build 18 (4), 351-370. Kociecki, M., Adeli, H., 2013. Two-phase genetic algorithm for size optimization of free-form steel spaceframe roof structures, J Constr Steel Res 90, 283-296.

619

Karami, K. and Akbarabadi, S. (2016), “Developing a smart structure using integrated subspace-based

620

damage detection and semi-active control,” Computer-Aided Civil and Infrastructure Engineering,

621

31:11, pp. 887-903.

622

Lin, Y.Z., Nie, Z.H., and Ma, H.W., (2017), “Structural Damage Detection with Automatic Feature-

623

extraction through Deep Learning,” Computer-Aided Civil and Infrastructure Engineering, 32:12, pp.

624 625 626 627

Kwon, K., and Kim, J. 2014. Progressive Collapse and Seismic Performance of Twisted Diagrid Buildings, International Journal of High-Rise Buildings, 3 (3): 223-230. Mahmoudi, M., Abdi, M.G., 2012. Evaluating response modification factors of TADAS frames. J Constr Steel Res 71, 162-170.

628

Mazzoni, S., McKenna, F., Scott, M. H., and Fenves, G. L. (2006). OpenSees command language manual.

629

Pacific Earthquake Engineering Research (PEER) Center, University of California, Berkeley, CA.

630

Mele E, Toreno M, Brandonisio G, De Luca Kim A., 2014. Diagrid structures for tall buildings: case studies

631

and design considerations. The Structural Design of Tall and Special Buildings 23, 124–145.

632

Milana G., Gkoumas K., Bontempi F., and Olmati P. 2015. Ultimate capacity of diagrid systems for tall

633

buildings in nominal configuration and damaged state. Periodica Polytechnica: Civil Engineering,

634

59(3), 381-391.

635 636

Ministry of Housing and Urban-Rural Development of China. 2010. Code for Seismic Design of Buildings, GB 50011-2010, Beijing, China.

637 638

Miranda, E., Bertero, V.V., 1994. Evaluation of strength reduction factors for earthquake-resistant design, Earthquake Spectra 10 (2), 357–379.

639

Moghaddasi B., N. S., Zhang Y. 2013. Seismic analysis of diagrid structural frames with shear-link fuse

640

devices. Earthquake Engineering and Engineering Vibration, 12, 463-472. DOI 10.1007/s11803-013-

641

0186-9.

642

Moon K. S., Connor J. J., Fernandez J. E., 2007. Diagrid Structural Systems for Tall Buildings:

643

Characteristics and Methodology for Preliminary Design. The Structural Design of Tall and Special

644

Buildings 16(2), 205–230.

645 646 647 648

Moon, K.S., 2008. Sustainable structural engineering strategies for tall buildings, The Structural Design of Tall and Special Buildings 17 (5), 895–914. Newmark, N.M., Hall, W.J., 1982. Earthquake spectra and design. EERI Monograph Series, Earthquake Engineering Research Institute, Oakland, CA.

649

Niu, Y., Fritzen, C.P., Jung, H., Buethe, I., Ni, Y.Q., Wang, Y.W., 2015. Online simultaneous

650

reconstruction of wind load and structural responses - theory and application to canton tower,

651

Computer-Aided Civil and Infrastructure Engineering 30 (8), 666–681.

652 653 654 655

Palomo, E.J., and Lopez-Rubio, E. (2016), “Learning Topologies with the Growing Neural Forest,” International Journal of Neural Systems, 26:3, 1650019 (21 page). Park, H.S. and Adeli, H. (1995), "A Neural Dynamics Model for Structural Optimization - Application to Plastic Design of Structures", Computers and Structures, Vol. 57, No. 3, pp. 391-399.

656

Pillon, P.E., Pedrino, E.C., Roda, V.O., Nicoletti, (2016)“A hardware oriented ad-hoc computer-based

657

method for binary structuring element decomposition based on genetic algorithm,” Integrated

658

Computer-Aided Engineering, 23:4, 2016, pp. 369-383.

659 660

Rafiei, M.H., Adeli, H., 2016. Sustainability in highrise building design and construction, The Structural Design of Tall and Special Buildings 25 (11), 643–658. doi: 10.1002/tal.1276

661

Shan, J., Shi, W., and Lu, X. (2016), “Model reference health monitoring of hysteretic building

662

structure using acceleration measurement with test validation,” Computer-Aided Civil and

663

Infrastructure Engineering, 31:6, pp. 449-464.

664 665

Siddique, N. and Adeli, H. (2013), Computational Intelligence - Synergies of Fuzzy Logic, Neural Networks and Evolutionary Computing, Wiley, West Sussex, United Kingdom (512 pages).

666 667 668 669

Siddique, N. and Adeli, H. (2017), Nature Inspired computing – Physics- and Chemistry-based Algorithms, CRC Press, Taylor & Francis, Boca Raton, Florida. Tashakori, A.R. and Adeli, H. (2002), “Optimum Design of Cold-Formed Steel Space Structures Using Neural Dynamic Model,” Journal of Constructional Steel Research, Vol. 58, No. 12, pp. 1545-1566.

670

Tsogka, C., Daskalakis, E., Comanducci, G., and Ubertini, F. (2017), “The stretching method for vibration-

671

based structural health monitoring of civil structures,” Computer-Aided Civil and Infrastructure

672

Engineering, 32:4, pp. 288-303.

673 674 675 676 677 678 679 680 681 682 683 684

Uang, C.M., Maarouf, A., 1994. Deflection amplification factor for seismic design provisions. J Struct Eng 120 (8), 2423-2436. Uriz, P. 2005. Towards earthquake resistant design of concentrically braced steel structures, Department of Civil and Environmental Engineering, University of California, Berkeley, CA. Vamvatsikos, D., and Cornell, C. A. 2002. Incremental dynamic analysis, Earthquake Engineering & Structural Dynamics, 31, 491–514. Vidic, T., Fajfar, P., Fischinger, M., 1994. Consistent inelastic design spectra: Strength and displacement, EQE Earthquake Engineering & Structural Dynamics 23, 507-521. Wang, N., Adeli, H., 2014. Sustainable Building Design, Journal of Civil Engineering and Management 20 (1), 1-10. Whittaker, A., Hart, G., Rojahn, C., 1999. Seismic response modification factors. J Struct Eng 125 (4), 438444.

685

Wright, J. and Jordanov, (2017) “Quantum Inspired Evolutionary Algorithms with Improved Rotation

686

Gates for Real-Coded Synthetic and Real World Optimization Problems,” Integrated Computer-Aided

687

Engineering, 24:3, 2017, pp. 203-223.

688

Yamin, L. E., Hurtado, A., Rincon, R., Dorado, J. F., and Reyes, J. C. 2017. Probabilistic seismic

689

vulnerability assessment of buildings in terms of economic losses. Engineering Structures, 138, 308-

690

323.

691 692 693 694

Young, K., Adeli, H., 2014. Fundamental period of irregular moment-resisting steel frame structures. The Structural Design of Tall and Special Buildings 23 (15), 1141-1157. Young, K., Adeli, H., 2014. Fundamental period of irregular concentrically braced steel frame structures. The Structural Design of Tall and Special Buildings 23 (16), 1211-1224.

695

Young, K., Adeli, H., 2016. Fundamental period of irregular eccentrically braced tall steel frame

696

structures. J Constr Steel Res 120, 199-205.

697

Zhang, A., Wang, K.C.P., Li, B., Yang, E., Dai, X., Peng, Y., Fei, Y., Liu, Y., Li, J.Q., and Chen,

698

C. (2017), “Automated Pixel-Level Pavement Crack Detection on 3D Asphalt Surfaces Using a

699

Deep-Learning Network,” Computer-Aided Civil and Infrastructure Engineering, 32:10, pp. 805-

700

819.

701

Zhong, Y. and Xiang, J. (2016), “A two-dimensional plum-blossom sensor array-based multiple

702

signal classification method for impact localization in composite structures,” Computer-Aided

703

Civil and Infrastructure Engineering, 31:8, pp. 633-643.

704 705

BIOSKETCHES OF AUTHORS

706

Esmaeel Asadi is a Ph.D. Candidate in Department of Civil Engineering at Case Western Reserve

707

University and former research assistant at The Ohio State University. His research interests

708

include seismic performance and resilience assessment of innovative structural systems including

709

steel diagrids and steel shear walls. He has recently published two journal papers on these topics

710

including a review paper on diagrid structures.

711

Hojjat Adeli received his Ph.D. from Stanford University in 1976 at the age of 26. He has authored

712

over 600 research and scientific publications in various fields of computer science, engineering,

713

applied mathematics, and medicine, including 16 high-technology books, and holds a United States

714

patent in the area of design optimization. He is the recipient of 55 awards and honors. In 1998 he

715

received the Distinguished Scholar Award, from The Ohio State University’s highest research

716

award “in recognition of extraordinary accomplishment in research and scholarship”. In 2010, he

717

was profiled as an Engineering Legend in the ASCE journal of Leadership and Management in

718

Engineering. He is a corresponding member of the Spanish Royal Academy of Engineering, a

719

foreign member of Lithuanian Academy of Sciences and Polish Academy of Science, a

720

Distinguished Member of ASCE, and a Fellow of AAAS, IEEE, AIMBE, and American

721

Neurological Association.

722

723 724

TABLES Table 1. Median expected engineering demand parameters DBE

725 726

MCE

Archetype

IDRmax (%)

IDRavg (%)

IDRmax/ IDRavg

IDRmax (%)

IDRavg (%)

4-45

0.50

0.44

1.16

0.71

0.62

1.17

4-63

0.55

0.47

1.17

0.93

0.69

1.41

4-72

3.04

0.86

3.49

5.03

1.41

3.54

8-45

1.24

0.96

1.25

1.77

1.48

1.19

8-63

0.65

0.54

1.26

0.95

0.75

1.31

8-72

1.61

0.58

2.76

2.70

0.86

3.39

IDRmax/ IDRavg

727 728

Table 2. Expected collapse capacity and IDR, the corresponding lognormal dispersion, the adjusted collapse margin and the probability of collapse

729 730

ŜCT (g)

Collapse IDRmax (%)

Prob. of collapse (%) under

4-45

3.75

𝛽𝛽𝑆𝑆𝐶𝐶𝐶𝐶

0.46

1.16

𝛽𝛽𝐼𝐼𝐼𝐼𝐼𝐼

0.53

2.4

0.6

5.6

4-63

3.07

0.52

1.5

0.62

2.0

3.6

15.3

4-72

3.35

0.47

5.91

0.42

2.1

1.5

9.5

8-45

3.15

0.65

1.37

0.41

2.0

6.9

19.5

8-63

2.93

0.52

1.25

0.57

2.0

4.4

17.6

8-72

2.86

0.43

2.21

0.46

1.8

2.2

14.1

Model

ACMR DBE

MCE

731

Table 3. Seismic performance parameters evaluated using four different methods Parameter

4-45

4-63

4-72

8-45

8-63

8-72

1545

1563

1572

3045

3063

3072

Vy

20.6

26.8

26.3

61.6

71.5

66.0

87.3

92.0

125

495

484

520

Ro= Vy /Vd

1.60

2.13

2.10

2.34

2.68

2.10

2.06

2.14

2.18

2.29

3.49

2.21

2.29 µ= δu/ δy Cd=µ Vy /Vd 3.66 Newmark-Hall:

2.69 5.73

2.33 4.89

2.29 5.36

3.93 10.5

2.42 5.08

2.31 4.77

2.09 4.47

4.41 9.60

1.70 3.88

1.99 6.96

3.39 7.50

1.89

2.09

1.91

1.89

2.62

1.96

2.31

2.09

2.80

1.70

1.99

3.39

R 3.02 Miranda-Bertero:

4.46

4.01

4.42

7.01

4.12

4.77

4.47

6.09

3.88

6.96

7.50





1.83

2.16

2.01

2.01

3.08

2.10

2.37

2.11

3.84

1.91

2.28

4.01

R

2.93

4.60

4.23

4.70

8.24

4.41

4.89

4.53

8.36

4.38

7.96

8.87

1.74

2.15

2.22

2.28

3.30

2.36

2.75

2.46

4.95

1.96

2.34

4.09

R 2.78 FEMA (2009):

4.58

4.67

5.33

8.84

4.96

5.67

5.28

10.7

4.48

8.17

9.04

Ro= Vmax /Vd Rµ R& Cd=R/BI

2.30 1.19

2.87 1.54

2.74 1.34

2.92 1.81

3.54 2.54

2.63 2.11

2.58 2.26

2.56 1.87

2.70 3.38

2.77 1.78

4.27 1.03

2.76 2.72

2.75

4.41

3.68

5.28

9.00

5.56

5.81

4.78

9.13

4.94

4.42

7.50

Vidic et al.: Rµ

732 733

734

Table 4. Statistical measures for seismic performance parameters Parameter

Mean

SD

Max

Min

Ro= Vy /Vd

2.28

0.43

3.49

1.60

µ= δu/ δy

2.65

0.79

4.41

1.70

Cd=µ Vy /Vd

6.03

2.10

10.51

3.66



2.22

0.47

3.39

1.70

R Miranda-Bertero:

5.06

1.39

7.50

3.02



2.48

0.72

4.01

1.83

5.67

1.96

8.87

2.93

2.72

0.90

4.95

1.74

R FEMA (2009):

6.21

2.29

10.76

2.78

Ro= Vmax /Vd

2.89

0.50

4.27

2.30



1.96

0.65

3.38

1.03

R and Cd=R/BI

5.60

1.90

9.13

2.75

Newmark-Hall:

R Vidic et al: Rµ

735 736

737

738 739 740

FIGURES

Fig. 1. Main components of a diagrid frame and its basic triangular element

741 742 743

Fig. 2. Main components of FEMA (2009) method for SPF evaluation

744 745 746 747

Fig. 3. Idealized force-displacement curve based on pushover analysis adapted from FEMA (2000; 2009)

748 749 750 751

Fig. 4. Variation of ductility factor (Rµ) versus period of the structure for three different ductility ratios of 2, 4, and 6 using three approaches NH, MB and VFF.

752 753 754

Fig. 5. Typical floor plan for (a) 4-, 8-, and 15-story (b) 30-story diagrid archetypes

755 756

Fig. 6. Diagrid patterns used in this research

757 758 759

(b) (a) Fig. 7. General member force-deformation relationship and modeling parameters adapted from ASCE/SEI 41-13 (2014) (a) flexural elements (b) diagonals

(a)

760 761

(b)

(c) (d) Fig. 8. Pushover curves for (a) 4- (b) 8- (c) 15- (d) 30-story archetypes

762 763 764

Fig. 9. Elevation of 4-72 model with uppermost incomplete module

765 766 767 768

Fig. 10. Response spectrum of scaled ground motion records and the design response spectrum for the 8-45 archetype

DBE (10%/50-yr)

MCE (2%/50-yr)

(a) IDRmax

(b) IDRavg

769 770 771

(c) IDRmax/IDRavg Fig. 11. Engineering demand parameters for 4-story archetypes (a) IDRmax (b) IDRavg (c) IDRmax to IDRavg ratio under DBE and MCE using NTHA

DBE (10%/50-yr)

MCE (2%/50-yr)

(a) IDRmax

(b) IDRavg

772 773 774

(c) IDRmax/IDRavg Fig. 12. Engineering demand parameters for 8-story archetypes (a) IDRmax (b) IDRavg (c) IDRmax to IDRavg ratio under DBE and MCE using NTHA

775 776 777

Fig. 13. Incremental dynamic analysis curves for 4-45 diagrid archetype

778 779 780

(b) (a) Fig. 14. Empirical CDF of Sa (T1,5%) and fitted lognormal fragility functions for (a) 4story and (b) 8-story archetypes

781 782 783 784

Fig. 15. Seismic ductility ratio (µ), overstrength factor (Ro), and deflection amplification factor (Cd)

785 786 787

Fig. 16. Seismic ductility factor (Rµ) using four different approaches

788 789 790 791

Fig. 17. Mean seismic performance factors, Ro, Rµ, and R, obtained using four different approaches (SD is shown in the middle of each bar)

792 793 794 795 796

Fig. 18. Seismic modification factor (R) using four different approaches