INDUSTRIAL ELECTRICAL SYMBOLS . . .

114 downloads 69348 Views 73KB Size Report
SYMBOLS FOR STATIC SWITCHING CONTROL DEVICES. ANTI- ... ELECTRICAL CIRCUITS WITHOUT USE OF CONTACTS,. STATIC ... CIRCUIT BREAKER.
INDUSTRIAL ELECTRICAL SYMBOLS . . .

LIMIT SWITCHES NORMALLY OPEN

NORMALLY CLOSED

HELD CLOSED

CIRCUIT BREAKER CIRCUIT BREAKER CIRCUIT BREAKER W/ THERMAL AND WITH THERMAL OL WITH MAGNETIC OL MAGNETIC OL

CIRCUIT INTERRUPTER

DISCONNECT

FOOT SWITCHES

HELD OPEN

SPEED (PLUGGING) F

PRESSURE AND LIQUID TEMPERATUREFLOW SWITCH VACUUM LEVEL ACTUATED (AIR, WATER, ETC.) SWITCHES SWITCH SWITCH

NO

NO

NO

NO

NO

NC

NC

NC

NC

NC

SYMBOLS FOR STATIC SWITCHING CONTROL DEVICES

ANTI-PLUG

F

STATIC SWITCHING CONTROL IS A METHOD OF SWITCHING ELECTRICAL CIRCUITS WITHOUT USE OF CONTACTS, PRIMARILY BY SOLID-STATE DEVICES. USE SYMBOLS SHOWN IN TABLE AND ENCLOSE THEM IN A DIAMOND.

F

INPUT COIL

R

OUTPUT NO

LIMIT SWITCH NO

LIMIT SWITCH NC

R

SELECTOR TWO-POSITION

J

THREE-POSITION

TWO-POSITION SELECTOR PUSHBUTTON SELECTOR POSITION

K

K

J

K

J

A1

K

L

A1

A1 A2

J

L

A1

X X

A2

A2

A

CONTACTS

B

1

2

3

4

X

B BUTTON

FREE DEPRESSED FREE DEPRESSED

A2

X

1 2 3 4

X-CONTACT CLOSED

A BUTTON X X

X

X

X - CONTACT CLOSED

X-CONTACT CLOSED

PUSHBUTTONS MOMENTARY CONTACT SINGLE CIRCUIT

DOUBLE CIRCUIT

MUSHROOM HEAD

NO AND NC NO

NC

©1999 American Technical Publishers, Inc.

MAINTAINED CONTACT WOBBLE STICK

TWO SINGLE CIRCUIT

ONE DOUBLE CIRCUIT

ILLUMINATED

R

. . . INDUSTRIAL ELECTRICAL SYMBOLS . . . OVERLOAD RELAYS

CONTACTS TIMED CONTACTS - CONTACT ACTION RETARDED AFTER COIL IS:

INSTANT OPERATING WITH BLOWOUT NO

WITHOUT BLOWOUT

NC

NO

ENERGIZED

NC

NOTC

THERMAL

MAGNETIC

DE-ENERGIZED

NCTO

NOTO

NCTC

SUPPLEMENTARY CONTACT SYMBOLS SPST NO SINGLE BREAK

SPST NC DOUBLE BREAK

SINGLE BREAK

SPDT DOUBLE BREAK

TERMS

SINGLE BREAK

DOUBLE BREAK

SPST SINGLE-POLE, SINGLE-THROW SPDT SINGLE-POLE, DOUBLE-THROW

DPST, 2NO SINGLE BREAK

DPST, 2NC

DOUBLE BREAK

SINGLE BREAK

DPST DOUBLE-POLE, SINGLE-THROW

DPDT

DOUBLE BREAK

SINGLE BREAK

DOUBLE BREAK

DPDT DOUBLE-POLE, DOUBLE-THROW NO NORMALLY OPEN NC NORMALLY CLOSED

METER (INSTRUMENT)

PILOT LIGHTS

TO INDICATE FUNCTION OF METER OR INSTRUMENT, PLACE SPECIFIED LETTER OR LETTERS WITHIN SYMBOL.

INDICATE TYPE BY LETTER

INDICATE COLOR BY LETTER NON PUSH-TO-TEST

AM or A V

AH A

AM

AMMETER AMPERE HOUR MICROAMMETER

mA

MILLAMMETER

PF

POWER FACTOR

V

VA

VOLTMETER

VAR

VARMETER

VARH

VARHOUR METER

PUSH-TO-TEST

R

A

WATTMETER

W

WATTHOUR METER

WH

VOLTMETER

COILS

INDUCTORS IRON CORE

DUAL-VOLTAGE MAGNET COILS HIGH-VOLTAGE LINK

AIR CORE

©1999 American Technical Publishers, Inc.

1

2

3

BLOWOUT COIL

LOW-VOLTAGE LINKS 4

1

2

3

4

. . . INDUSTRIAL ELECTRICAL SYMBOLS . . . TRANSFORMERS AUTO

AIR CORE

CURRENT

AUTOTRANSFORMER FOR REDUCEDVOLTAGE STARTING

CONTROL TRANSFORMER SINGLEVOLTAGE

DUALVOLTAGE H3

H1

H2

X2

%

50

50

65

65

80

80

100

100

0

0

H2

H1

X1

%

H4

X2

X1

AC MOTORS SINGLEPHASE T1

SEPARATE PHASE, TWO-SPEED T2

SEPARATE WINDING, TWO-SPEED

THREE-PHASE

HIGH

COM

LOW

T1

T2

T3

T1

T2

T1

T3

CONSTANT-TORQUE, TWO-SPEED

T11

T4

T1

T3

T3

CONSTANTHORSEPOWER, TWO-SPEED

VARIABLE-TORQUE, TWO-SPEED T4

WYE/DELTA, REDUCEDVOLTAGE

T2

T13

T1 T6

T3

T5

T2

T3

T5

T3 T5

T6

T6

T2

T5

T6

T2

DC MOTORS ARMATURE

T9

T4 T4

T2

T7 T8

T1

T1

T3

T5

T6

T2

WYE-CONNECTED, PART WINDING, REDUCED-VOLTAGE

T4 T1

T12

WIRING

SHUNT FIELD

SERIES FIELD

COMM OR COMPENS FIELD

SHOW 4 LOOPS

SHOW 3 LOOPS

SHOW 2 LOOPS

CONNECTIONS

NOT CONNECTED

POWER

WIRING TERMINAL

CONNECTED

CONTROL

GROUND

MECHANICAL

ARM

MECHANICAL INTERLOCK

CONTROL AND POWER CONNECTIONS-600 V OR LESS ACROSS-THE-LINE STARTERS 1 LINE MARKINGS

L1, L2

L1, L3 PHASE 1 L2, L4 PHASE 2

L1 IS ALWAYS UNGROUNDED

GROUND WHEN USED MOTOR RUNNING OVERCURRENT UNITS IN

2 , 4-WIRE

1 ELEMENT 2 ELEMENT 3 ELEMENT

CONTROL CIRCUIT CONNECTED TO FOR REVERSING INTERCHANGE LINES

©1999 American Technical Publishers, Inc.

3 L1, L2, L3 L2

L1 L1, L4 L1, L2, L3 L1, L2

L1, L3

L1, L2

L1, L3

L1, L3

. . . INDUSTRIAL ELECTRICAL SYMBOLS RESISTORS ADJUSTABLE BY FIXED TAPS

FIXED

CAPACITORS RHEOSTAT, POT, OR ADJUSTABLE TAP

FIXED

ADJUSTABLE

POLARIZED

RES

_

+ RES

H

RES

HEATING ELEMENT

BUZZER

BELL

FUSE POWER OR CONTROL

HORN, SIREN, ETC.

HALF-WAVE RECTIFIER

FULL-WAVE RECTIFIER AC

+

_

DC

DC

AC

BATTERY

SEMICONDUCTORS . . .

IGNITRON TUBE

THERMOCOUPLE

UNIDIRECTIONAL BREAKDOWN (ZENER) DIODE

TUNNEL DIODE

DIODE DOT IN TUBE DENOTES GAS _

+

. . . SEMICONDUCTORS . . . BIDIRECTIONAL BREAKDOWN DIODE

TRIAC (BIDIRECTIONAL TRIODE THYRISTOR)

PHOTOSENSITIVE CELL

SILICON CONTROLLED RECTIFIER

PROGRAMMABLE UNIT - JUNCTION TRANSISTOR (PUT)

. . . SEMICONDUCTORS TRANSISTOR PNP BASE

UNIJUNCTION TRANSISTOR NPN BASE

(C)

P BASE (C) (E)

(B)

N BASE (B2)

(E)

(B2)

(B)

(E)

©1999 American Technical Publishers, Inc.

(E)

(B1)

(B1)