1) Flue calculation values apply in countries where flue calculation in accordance
with DIN 18160 or DIN EN 13384 is required. 2) The flue is installed on top of ...
CENTUS PRODUCT INFORMATION: Thermal energy: Energy efficiency: CO%: Nominal heat output: Heat storage capacity:
35-40 kWh 84 % 0,08 % 2,9 kW / 2,0 h
100%
CENTUS 1 (white)
CENTUS 2 (white)
CENTUS 3 (white)
LAYOUT DRAWINGS AND CHANGE OPTIONS:
2,5 h
50%
9,6 h
25%
15,3 h
PRODUCT NUMBERS Product
Product number
Weight kg
Height mm
CENTUS 1
703221-1
555
1650
CENTUS 2
703221-2
555
1650
CENTUS 3
703221-3
555
1650
Standard colours: White, RAL 9010 Pure white, gloss 78 % Black, RAL 9005 Jet black, gloss 25 %
NunnaUuni special colours (by order): CENTUS 1
CENTUS 2
CENTUS 3
Blueberry Vanilla Mocca Lime Actual colours may vary from those printed
ACCESSORIES: - Floor protector (in front of the stove) - Rear heat shield Rear heat shield to reduce the safety distance
NunnaUuni Oy reserves the right to make alterations 06/13
PRODUCT INFORMATION FIREWOOD
Centus
FLUE CALCULATION VALUES (1
MAX. FLUE TEMPERATURE IN SECURITY TEST
Length [cm]
Max amount of wood [kg]
Length baking oven [cm]
Flue gas temperature [°C]
Min. flue draught [Pa]
Mass flow [g/s]
Burning heat output [kW]
Flue connection [A/B] Ø
Burning air approx. m³/h
Temperature °C
25
10
-
215
11
15,1
15,8
150
40
320
FLUE CONNECTION TABLE RECOMMENDED FLUE [mm] approx. 150x150
approx. 150x200
approx. 150x300
round Ø
Centus (2
-
-
-
150
Centus (3
x
x
-
150-180
SAFETY DISTANCES TO COMBUSTIBLE MATERIALS According to the EN 15250 Behind
On the sides
To the front
Centus
150
150
1100
Centus with heat shield
50
150
1100
1) Flue calculation values apply in countries where flue calculation in accordance with DIN 18160 or DIN EN 13384 is required. 2) The flue is installed on top of the fireplace. 3) The fireplace is connected to the flue using a connection pipe. NOTES! The flue heat category required by the fireplace is T400. The recommended minimum flue height is 3,5 m. In countries where the flue calculation is required, should the calculation be done according to the instructions and regulations of the flue calculation. A flue damper is not necessary for the flue. If a flue damper is installed, it must be equipped with an opening of at least 20 cm². The flue damper must not be closed before the embers have burned out!
NunnaUuni Oy reserves the right to make alterations 06/13
GENIUS PRODUCT INFORMATION: Thermal energy: Energy efficiency: CO%: Nominal heat output: Heat storage capacity:
35-40 kWh 84 % 0,08 % 2,9 kW / 2,0 h
100%
GENIUS
LAYOUT DRAWINGS AND CHANGE OPTIONS:
2,5 h
50%
9,6 h
25%
15,3 h
PRODUCT NUMBERS: Product
Product number
Weight kg
Height mm
GENIUS
703241-1
560
1904
Standard colours: White, RAL 9010 Pure white, gloss 78 % Black, RAL 9005 Jet black, gloss 25 %
NunnaUuni special colours (by order): GENIUS
Blueberry Vanilla Mocca Lime Actual colours may vary from those printed
ACCESSORIES: - Floor protector (in front of the stove) - Rear heat shield
Rear heat shield to reduce the safety distance
NunnaUuni Oy reserves the right to make alterations 06/13
PRODUCT INFORMATION FIREWOOD
Genius
FLUE CALCULATION VALUES (1
MAX. FLUE TEMPERATURE IN SECURITY TEST
Length [cm]
Max amount of wood [kg]
Length baking oven [cm]
Flue gas temperature [°C]
Min. flue draught [Pa]
Mass flow [g/s]
Burning heat output [kW]
Flue connection [A/B] Ø
Burning air approx. m³/h
Temperature °C
25
10
-
215
11
15,1
15,8
150
40
320
FLUE CONNECTION TABLE RECOMMENDED FLUE [mm] approx. 150x150
approx. 150x200
approx. 150x300
round Ø
Genius (2
-
-
-
150
Genius (3
x
x
-
150-180
SAFETY DISTANCES TO COMBUSTIBLE MATERIALS According to the EN 15250 Behind
On the sides
To the front
Genius
150
150
1100
Genius with heat shield
50
150
1100
1) Flue calculation values apply in countries where flue calculation in accordance with DIN 18160 or DIN EN 13384 is required. 2) The flue is installed on top of the fireplace. 3) The fireplace is connected to the flue using a connection pipe. NOTES! The flue heat category required by the fireplace is T400. The recommended minimum flue height is 3,5 m. In countries where the flue calculation is required, should the calculation be done according to the instructions and regulations of the flue calculation. A flue damper is not necessary for the flue. If a flue damper is installed, it must be equipped with an opening of at least 20 cm². The flue damper must not be closed before the embers have burned out!
NunnaUuni Oy reserves the right to make alterations 06/13
FIDUS PRODUCT INFORMATION: Thermal energy: Energy efficiency: CO%: Nominal heat output: Heat storage capacity:
FIDUS 1
FIDUS 2
LAYOUT DRAWINGS AND CHANGE OPTIONS:
35-41 kWh 88 % 0,09 % 2,2 kW / 4,1 h
100%
2,4 h
50%
11,4 h
25%
21,6 h
PRODUCT NUMBERS: Product
Product number
Weight kg
Height mm
FIDUS 1
703211-1
875
1825
FIDUS 2
703211-2
875
1825
ACCESSORIES: Product
FIDUS
Product number
Weight kg
FLOOR PROTECTOR
900348
6
BOTTOM PLINTH
200622
107
BOTTOM PLINTH ADDITIONAL STONES (+384mm)
200624
56
PARTS FOR BACK CONNECTION
900392
5
FIDUS with additional stones for bottom plinth Please notify: Bottom plinth is an accesory. Bottom plinth stones are polished only on 2 visible sides. Additional stones for bottom plinth are polished only from one visible side.
900392
NunnaUuni Oy reserves the right to make alterations 06/13
PRODUCT INFORMATION FIREWOOD
Fidus
FLUE CALCULATION VALUES (1
MAX. FLUE TEMPERATURE IN SECURITY TEST
Length [cm]
Max amount of wood [kg]
Length baking oven [cm]
Flue gas temperature [°C]
Min. flue draught [Pa]
Mass flow [g/s]
Burning heat output [kW]
Flue connection [A/B] Ø
Burning air approx. m³/h
Temperature °C
25
10
-
187
12
15,1
15,8
150
40
320
FLUE CONNECTION TABLE RECOMMENDED FLUE [mm]
CONNECTIONPART
approx. 150x150
approx. 150x200
approx. 150x300
round Ø
inner Ø
outer Ø
Fidus (2
-
-
-
150
160
-
Fidus (3
x
x
-
150-180
-
160
SECURITY DISTANCES TO COMBUSTIBLE MATERIALS According to the EN 15250
Fidus
Behind
On the sides
To the front
100
150
1100
1) Flue calculation values apply in countries where flue calculation in accordance with DIN 18160 or DIN EN 13384 is required. 2) The flue is installed on top of the fireplace. 3) The fireplace is connected to the flue using a connection pipe. NOTES! The flue heat category required by the fireplace is T400. The recommended minimum flue height is 3,5 m. In countries where the flue calculation is required, should the calculation be done according to the instructions and regulations of the flue calculation. A flue damper is not necessary for the flue. If a flue damper is installed, it must be equipped with an opening of at least 20 cm². The flue damper must not be closed before the embers have burned out!
NunnaUuni Oy reserves the right to make alterations 06/13