LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

LMP91300 Industrial Inductive Proximity Sensor AFE 1 Features

3 Description

• • • • • • •

The LMP91300 is a complete analog front end (AFE) optimized for use in industrial inductive proximity sensors. The LMP91300 directly converts the RP of the external LC tank into a digital value.

1

• • • • • •

Post Production Configuration and Calibration Programmable Decision Thresholds Programmable Hysteresis Flexible Overload Protection Digital Temperature Compensation Integrated LED driver Small Form Factor, Supports 4mm Sensors (DSBGA Package) Low Power Consumption Integrated Voltage Regulator 3-Wire Capability Supports NPN and PNP Modes Normally Open (NO) and Normally Closed (NC) Supported 16-bit Resolution Threshold Setting

Post-manufacturing configuration and calibration is fully supported. The temperature dependence of the sensor is digitally compensated, using an external temperature sensor. The LMP91300 provides programmable thresholds, programmable temperature compensation and programmable oscillation frequency range. Due to its programmability, the LMP91300 can be used with a wide variety of external inductors and its detection thresholds can be adjusted to the desired detection distances. An internal voltage regulator allows the device to operate with a supply from 6.5V to 40V. The output can be programmed to drive an external transistor in either NPN or PNP mode.

2 Applications • • •

Available in 4mm × 5mm 24-terminal WQFN and 2.05mm × 2.67mm 20-terminal DSBGA packages, the LMP91300 operates from -40°C to +125°C.

Industrial Proximity Detection Industrial Production Lines Industrial Automation

Device Information ORDER NUMBER

PACKAGE

BODY SIZE

LMP91300NHZ

WQFN (24)

4mm x 5mm

LMP91300YZR

DSBGA (20)

2.05mm x 2.67mm

3-Wire PNP Configuration 6.5V to 40V

REXT B

C1 RSENSE

+

R1

-

CFB

LED

CFA CF

EXT B

CV+/EXT E Load V+/EXT E SWDRV

INA

LMP91300 SENSE1+ INB

NTC

SENSE2+ CBY

TEMP+

GND SENSECBY

3-Wire PNP

1

An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. PRODUCTION DATA.

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

Table of Contents 1 2 3 4 5 6

7

Features .................................................................. Applications ........................................................... Description ............................................................. Revision History..................................................... Terminal Configuration and Functions................ Specifications.........................................................

1 1 1 2 3 5

6.1 6.2 6.3 6.4 6.5 6.6 6.7

5 5 5 5 6 7 8

Absolute Maximum Ratings ..................................... Handling Ratings....................................................... Recommended Operating Conditions....................... Thermal Information .................................................. Electrical Characteristics .......................................... Timing Requirements ................................................ Typical Characteristics ..............................................

Detailed Description ............................................ 11 7.1 Overview ................................................................. 11 7.2 Functional Block Diagram ....................................... 11

7.3 7.4 7.5 7.6

8

Feature Description................................................. Device Functional Modes........................................ Programming........................................................... Register Maps .........................................................

11 14 14 18

Application and Implementation ........................ 28 8.1 Application Information............................................ 28 8.2 Typical Application .................................................. 28

9 Power Supply Recommendations...................... 35 10 Layout................................................................... 35 10.1 Layout Guidelines ................................................. 35 10.2 Layout Example .................................................... 36

11 Device and Documentation Support ................. 37 11.1 Trademarks ........................................................... 37 11.2 Electrostatic Discharge Caution ............................ 37 11.3 Glossary ................................................................ 37

12 Mechanical, Packaging, and Orderable Information ........................................................... 37

4 Revision History NOTE: Page numbers for previous revisions may differ from page numbers in the current version. Changes from Revision A (September 2013) to Revision B

Page



Changed layout to new datasheet format............................................................................................................................... 1



Added Burn Current Specification. ......................................................................................................................................... 6



Added additional information to Low RP, Close Target, Under Range Switch Enable section. .......................................... 12



Changed typo. ..................................................................................................................................................................... 31



Added additional information to REXTB section. .................................................................................................................... 31

Changes from Original (September 2013) to Revision A

Page



Changed to Production Data ................................................................................................................................................. 1



Added CSP package ............................................................................................................................................................. 3

2

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

5 Terminal Configuration and Functions

CBY

TEMP+

TEMP-

INB

INA

24

23

22

21

20

LMP91300 WQFN Top View

P1

1

19

GND

P2

2

18

CFA

P3

3

17

CFB

P4

4

16

NC

DAP (GND)

13

SENSE2+/SWIF RX

12

7

SENSE1+

LED

11

NC

SENSE-

14

10

6

SWDRV

GND

9

GND

EXT B

15

8

5

V+/EXT E

P5

LMP91300 WQFN Terminal Functions TERMINAL NUMBER

NAME

TYPE

DESCRIPTION

1-5

P1-5

G

Connect to Ground

6

GND

G

Board Ground

7

LED

O

LED Driver Output

8

V+/EXT E

P

Chip V+/External transistor, emitter

9

EXT B

P

External transistor, base

10

SWDRV

O

Drive for external transistor switch

11

SENSE-

I

Negative sense Input

12

SENSE1+

I

Positive sense Input

13

SENSE2+/SWIF RX

I

Positive sense Input and Single Wire Interface receive

14

NC

N/A

15

GND

G

16

NC

N/A

17

CFB

I

Filter capacitor value based on sensor oscillation frequency

No connect Board ground No connect

18

CFA

I

Filter capacitor value based on sensor oscillation frequency

19

GND

G

Board ground

20

INA

I

External LC tank

21

INB

I

External LC tank

22

TEMP-

G

NTC ground, connect to board ground

23

TEMP+

I

Analog Temperature Sensor Input

24

CBY

O

Bypass capacitor (56nF)

DAP

DAP

G

Connect to Ground

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

3

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

LMP91300 DSBGA 1

2

3

4

4

3

2

1

INA

INB

TEMP+

CBY

CBY

TEMP+

INB

INA

A1

A2

A3

A4

A4

A3

A2

A1

CFA

P2

TEMP-

P1

P1

TEMP-

P2

CFA

B3

B2

B1

A

B1

B2

B3

B4

B4

CFB

P5

P4

P3

P3

P4

P5

CFB

C1

C2

C3

C4

C4

C3

C2

C1

S2+

S-

GND

LED

LED

GND

S-

S2+

D1

D2

D3

D4

D4

D3

D2

D1

S1+

SWDRV

EXT B

V+/EXT E

V+/EXT E

EXT B

SWDRV

S1+

E1

E2

E3

E4

E4

E3

E2

E1

B

C

D

E

A

B

C

D

E

Bottom View

Top View

LMP91300 DSBGA Terminal Functions

4

TERMINAL NUMBER

NAME

TYPE

A1

INA

I

External LC tank

A2

INB

I

External LC tank

A3

TEMP+

I

Analog Temperature Sensor Input

A4

CBY

O

Bypass capacitor (56nF)

B1

CFA

I

Filter capacitor value based on sensor oscillation frequency

B2

P2

G

Connect to Ground

B3

TEMP-

G

NTC ground, connect to board ground

DESCRIPTION

B4

P1

G

Connect to Ground

C1

CFB

I

Filter capacitor value based on sensor oscillation frequency

C2

P5

G

Connect to Ground

C3

P4

G

Connect to Ground

C4

P3

G

Connect to Ground

D1

SENSE2+/SWIF RX

I

Positive sense Input and Single Wire Interface receive

D2

SENSE-

I

Negative sense Input

D3

GND

G

Board ground

D4

LED

O

LED Driver Output

E1

SENSE1+

I

Positive sense Input

E2

SWDRV

O

Drive for external transistor switch

E3

EXT B

P

External transistor, base

E4

V+/EXT E

P

Chip V+/External transistor, emitter

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

6 Specifications 6.1 Absolute Maximum Ratings

(1)

Over operating free-air temperature range (unless otherwise noted) MIN Voltage at Terminals 1-5, 7, 10, 11, 17, 18 (B1, B2, B4, C1, C2, C3, C4, D2, D4, E2)

MAX

UNIT

(V+) + 0.3

V

Voltage at Terminals 6, 15, 19, 22 (B3, D3)

0.3

V

Voltage at Terminal 8 (E4)

6

V

Voltage at Terminal 9 (E3)

7

V

Voltage at Terminals 12, 13 (D1, E1)

48

V

Current at Terminals 20, 21 (A1, A2)

8

mA

Voltage at Terminals 23, 24 (A3, A4)

1.6

V

+125

°C

+150

°C

−40

Operating Temperature, TA Junction Temperature, TJ (2) (1) (2)

Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. The maximum power dissipation is a function of TJ(MAX), θJA, and TA. The maximum allowable power dissipation at any ambient temperature is PD = (TJ(MAX) - TA)/ θJA . All numbers apply for packages soldered directly onto a PC board.

6.2 Handling Ratings TSTG HBM

(1) (2)

CDM (1) (3) (1) (2) (3)

MIN

MAX

UNIT

−65

+150

°C

Human Body Model

2000

V

Charge-Device Model

500

V

Storage Temperature

Electrostatic discharge (ESD) to measure device sensitivity and immunity to damage caused by assembly line electrostatic discharges in to the device. Level listed above is the passing level per ANSI, ESDA, and JEDEC JS-001. JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. Level listed above is the passing level per EIA-JEDEC JESD22-C101. JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.

6.3 Recommended Operating Conditions Over operating free-air temperature range (unless otherwise noted) MIN VLOOP

Loop Voltage

NOM

MAX

6.5

UNIT

40

V

MAX

UNIT

6.4 Thermal Information (1) (2) Over operating free-air temperature range (unless otherwise noted) PARAMETER

TEST CONDITIONS

θJA

Package Thermal Impedance

24-Terminal WQFN

θJA

Package Thermal Impedance

20-Terminal DSBGA

(1) (2)

MIN

TYP 33.2

°C/W

46

°C/W

The maximum power dissipation is a function of TJ(MAX), θJA, and TA. The maximum allowable power dissipation at any ambient temperature is PD = (TJ(MAX) - TA)/ θJA . All numbers apply for packages soldered directly onto a PC board. The package thermal impedance is calculated in accordance with JESD 51-7.

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

5

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

6.5 Electrical Characteristics

www.ti.com

(1) (2)

Unless otherwise specified, all limits are ensured at TA = TJ = 25°C, Loop Voltage = 24V. (3). Boldface limits apply at the temperature extremes. SYMBOL

PARAMETER

CONDITIONS

MIN (4)

TYP (5)

MAX (4)

UNIT

POWER SUPPLY IV+

Supply Current

Does not include external currents such as LED, SWDRV, and LC tank current (6) (3)

IBURN

Burn Current

Additional current needed to burn registers

tSTART

Power On Start Time

LC Tank oscillation = 1MHz, RESPONSE_TIME = 001b (96), measured time starting from when supply is at 90% of operational value. (7)

3 mA 3.6

mA 50 ms

OSCILLATOR fMIN

Minimum Oscillation Frequency

0.005

MHz

fMAX

Maximum Oscillation Frequency

5

MHz

OSCAMP1V Oscillator Amplitude

OSC_AMP = 00b

1

VPP

OSCAMP2V Oscillator Amplitude

OSC_AMP = 01b

2

VPP

OSCAMP4V Oscillator Amplitude

OSC_AMP = 10b

4

VPP

trec

Recovery Time

Oscillation start up time after low RP is removed.

10

oscillator periods

RPMIN

Minimum RP Value of LC Tank

See OSC_CONFIG_2 entry in the Register Maps section.

798

RPMAX

Maximum RP Value of LC Tank

See OSC_CONFIG_2 entry in the Register Maps section.

3.93M

Response time

Settling time of digital filter to RP step. See RESPONSE_TIME in registers 0x71 and 0x77.

SENSOR Ω Ω

DETECTOR tRESP

96

6144

oscillator periods

OUTPUT DRIVER ISOURCE, SINK

Current source and sink capability on SWDRV Terminal

SWDRV_CURRENT = 00b

2

2.5

3

SWDRV_CURRENT = 01b

3.25

3.75

4.25

SWDRV_CURRENT = 10b

4.5

5

5.5

SWDRV_CURRENT = 11b

9

10

11

mA

OVERLOAD PROTECTION

(1) (2) (3) (4) (5) (6) (7) 6

Over Current Detection Threshold

NPN Configuration, Using external SENSE resistor

279

310

341

Over Current Detection Threshold

PNP Configuration, Using external SENSE resistor

248

310

376

Over Current Limit

NPN Configuration

432

480

528

mV

Over Current Limit

PNP Configuration

413

480

547

mV

mV mV

Electrical Characteristics Table values apply only for factory testing conditions at the temperature indicated. Factory testing conditions result in very limited self-heating of the device such that TJ = TA. Parametric performance shown in the electrical tables is not ensured under conditions of internal self-heating where TJ > TA. Electrical Characteristics apply only when SWIF is inactive. Glitches may appear on SWDRV during a SWIF transmission. There are tradeoffs between power consumption, switching speed, RP to Digital conversion and oscillation frequency. Limits are ensured by testing, design, or statistical analysis at 25°C. Limits over the operating temperature range are ensured through correlations using statistical quality control (SQC) method. Typical values represent the most likely parametric norm as determined at the time of characterization. Actual typical values may vary over time and will also depend on the application and configuration. The typical values are not tested and are not ensured on shipped production material. Supply current is higher when there is not an LC tank connected to Terminals INA and INB because an internal protection circuit is enabled. See the Supply Current vs Supply Voltage graphs in the Typical Characteristics section. The loop supply must be able to momentarily supply 30mA. Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

Electrical Characteristics (1)(2) (continued) Unless otherwise specified, all limits are ensured at TA = TJ = 25°C, Loop Voltage = 24V.(3). Boldface limits apply at the temperature extremes. SYMBOL

PARAMETER

CONDITIONS

MIN (4)

TYP

MAX

UNIT

30

35

µs

(5)

(4)

INPUT SHORT CONDITION tOUT

Output Switching

Output high time in short condition

duty0.1%

Output duty cycle during short condition

During short, SHORTCKT_DUTY_CYCLE = 0b

25

0.1%

duty0.8%

Output duty cycle during short condition

During short, SHORTCKT_DUTY_CYCLE = 1b

0.8%

LEDBLINK

LED Blinking Rate

Blinking rate of the LED during a short condition or ECC error

2

Hz

LED DRIVER Sink Current

LED_CURRENT = 0b

2

2.5

3

mA

Sink Current

LED_CURRENT = 1b

4

5

6

mA

-2.5

1

2.5

TEMPERATURE SENSOR Accuracy

Accuracy of the LMP91300 only, does not include the accuracy of the NTC

°C

6.6 Timing Requirements SWIF TIMING

MIN Communication rate

TYP

1

“D” symbol duty cycle: THD/TP

½

“0” symbol duty cycle: TH0/TP

¼

“1” symbol duty cycle: TH1/TP

¾

MAX

UNIT

10

kbits/s

³0´ TH0

³'´

THD

³1´

TH1 TP

Figure 1. Single-Wire Interface (SWIF) Timing Diagram

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

7

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

6.7 Typical Characteristics At TA = TJ = 25°C, Loop Voltage = 20V to 36V, unless otherwise specified. 14500

5.0 Temperature Sensor Accuracy

4.0

14000

3.0 Accuracy (ƒC)

RP (Dec)

13500 13000 12500

Register Settings RP_MAX = 0x12 RP_MIN = 0x18 RESONATOR_MIN_FREQ = 0x91 OSC_AMP = 4V RESPONSE_TIME = 6144

12000 11500

3.959mm

5000

10000

15000

25000

0.0

±1.0

±3.0

4.04mm

20000

1.0

±2.0

4mm

±4.0

11000 0

2.0

30000

Samples

Using Murata NTC: NCP03WF104F05RL

±5.0 ±40.0 ±20.0

20.0

40.0

60.0

80.0 100.0 120.0

Temperature (ƒC)

Figure 2. RP Resolution

C004

Figure 3. Temperature Accuracy

4.5

4.5 LC Tank connected to INA and INB RP_MAX = 0x12 RP_MIN = 0x18 RESONATOR_MIN_FREQ = 0x91 OSC_AMP = 1V LC Tank Oscillation Frequency with no Target = 317kHz

3.5

LC Tank connected to INA and INB RP_MAX = 0x12 RP_MIN = 0x18 RESONATOR_MIN_FREQ = 0x91 OSC_AMP = 2V LC Tank Oscillation Frequency with no Target = 317kHz

4.0 Supply Current (mA)

4.0 Supply Current (mA)

0.0

C003

-40ƒC

3.0

+25ƒC 2.5

3.5

-40ƒC

3.0

+25ƒC 2.5

+85ƒC

+85ƒC

+125ƒC

+125ƒC

2.0

2.0 5

10

15

20

25

30

35

Supply (V)

40

5

10

Figure 4. Supply Current vs Supply Voltage

15

20

25

30

35

Supply (V)

C005

40 C005

Figure 5. Supply Current vs Supply Voltage

4.5

-40ƒC SENSE- Pin +25ƒC

Supply Current (mA)

4.0

SWDRV Pin +85ƒC

3.5

2mA/DIV

+125ƒC LC Tank connected to INA and INB RP_MAX = 0x12 RP_MIN = 0x18 RESONATOR_MIN_FREQ = 0x91 OSC_AMP = 4V LC Tank Oscillation Frequency with no Target = 317kHz

3.0

2.5

200mV/DIV

2.0 5

10

15

20

25

30

35

Supply (V)

C001

C005

Figure 6. Supply Current vs Supply Voltage

8

10µs/DIV

40

Figure 7. SWDRV and SENSE- Waveforms During Short Condition, SHORTCKT_DUTY_CYCLE = 0.1% Or 0.8%

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

Typical Characteristics (continued) At TA = TJ = 25°C, Loop Voltage = 20V to 36V, unless otherwise specified. 600

400 Loop Voltage = 24V

Frequency (Count)

250 200 150 100

350 300 250

200 150

Duty Cycle (%)

0.1

0.09998

0.09996

0.09992

0.0999

0.09988

0.09986

0.09994

Duty Cycle (%)

C013

Figure 10. 0.8% Duty Cycle Distribution, PNP Mode

0.8

0.7998

0.7996

0.7994

0.8

0.7998

0.7996

0.7994

0.7992

0.799

0.7988

0.7986

0.7984

50

0.7992

100

0.799

150

0.7988

200

0.7986

250

Loop Voltage = 24V

0.7984

300

700 650 600 550 500 450 400 350 300 250 200 150 100 50 0

0.7982

Frequency (Count)

400

0.7982

0.09984

Figure 9. 0.1% Duty Cycle Distribution, NPN Mode

Loop Voltage = 24V

350

C012

Duty Cycle (%)

Figure 8. 0.1% Duty Cycle Distribution, PNP Mode

0.798

0.09982

C011

500 450

0.0998

0

0.1

0.09998

0.09996

0.09994

0.09992

0.0999

0.09988

0.09986

0.09984

0.09982

0.0998

50

Duty Cycle (%)

Frequency (Count)

400

100

50

0

450

0.798

Frequency (Count)

500

300

0

Loop Voltage = 24V

550

350

C014

Figure 11. 0.8% Duty Cycle Distribution, NPN Mode

SENSE- Pin SWDRV Pin

2mA/DIV

200mV/DIV

2ms/DIV

C009

Figure 12. SWDRV and SENSE- Waveforms During Short Condition, SHORTCKT_DUTY_CYCLE = 0.1% Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

9

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

SENSE- Pin SWDRV Pin

2mA/DIV

200mV/DIV

500µs/DIV

C010

Figure 13. SWDRV and SENSE- Waveforms During Short Condition, SHORTCKT_DUTY_CYCLE = 0.8%

10

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

7 Detailed Description 7.1 Overview The LMP91300 is a complete analog front end (AFE) optimized for use in inductive proximity sensors. The LMP91300 detects the presence of a metal object based on the RP change of an LC oscillator, depending on the distance of the metal object. The LMP91300 is based on a novel architecture that directly converts the RP of the external LC tank to a digital value. Post manufacturing configuration and calibration is fully supported by the architecture of the LM91300. The temperature dependence of the sensor is digitally compensated, using an external temperature sensor. The LMP91300 provides programmable thresholds, programmable temperature compensation and programmable oscillation frequency range. Due to its programmability, the LMP91300 can be used with a wide variety of external inductors and its detection thresholds can be adjusted to the desired detection distances. The internal LDO has a high input voltage capability, while the architecture enables the use of a low supply as well. The output can be programmed to drive an external transistor in either NPN or PNP mode.

EXT B

V+/EXT E

7.2 Functional Block Diagram

OTP Memory

Direct RP to Digital Converter

Digital Temp Correction

TEMP

CFB

CFA

Temp Sensor

Comparator

SENSE1+

SENSE1+

SENSE2+

SENSE2+/ SWIF RX

Driver

LED Drive

Serial Interface

DRIVE

SWDRV

SENSE-

SENSE-

GND

INB

CBY

Oscillator

LED

INA

Voltage Regulator

7.3 Feature Description 7.3.1 Oscillator The oscillator, using an external LC tank (the detector), provides a wide oscillation range from 5kHz to 5MHz. The RP upper and lower limits are programmable, to support a wide range of LC combinations. Within the RP range of the LC tank, the oscillator amplitude is kept constant. When the LC tank RP drops below the lower programmed limit of RP the LMP91300 detects that the target is too close, the amplitude is reduced and the detector output will rail. See Figure 14.

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

11

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

Feature Description (continued) Oscillator dies

Normal operation

ADC saturated, RXWSXWLQJ³RQHV´

ADC saturated, 2XWSXWLQJ³]HURV´, Oscillator running Switch opens

Switch closes Hysteresis 1

2

RP = 1.25k

RP_MIN

Threshold open

4

RP_MAX

RP = 5M

Threshold close

ADC Out

Full Scale

3

0 0

f

Distance to target :

Figure 14. Operating Region 7.3.2 Detection The RP of the external LC tank is directly converted to a digital signal. With this approach the only temperature compensation needed is that for RP, which is done through the Look Up Table (Registers 0x00 to 0x5D). 7.3.3 Comparator The internal digital comparator accepts the signal from the RP to digital converter, after temperature compensation, and makes a decision, based on the value written to the DET_H_MSB and DET_H_ LSB registers. Programmable hysteresis is set by the value in the DET_L_MSB and DET_L_ LSB registers. The detection threshold can be set within the programmed RP range. 7.3.4 Low RP, Close Target, Under Range Switch Enable If RP drops below the detectable range, the LMP91300 remains functional. The following applies if at least one temperature conversion has been completed: For low RP start up (for example, if the target is in contact with the sensing coil when the part is powered on) UNDER_RANGE_SWITCH_EN must be set to 1 for the switch to be enabled. If UNDER_RANGE_SWITCH_EN is set to 0, the startup state is undefined when the sensor RP < RPMIN (for example, if the target is in contact with the sensing coil). 1. If RP < 798Ω (for example, the metal plate is against the sensor) before the fourth conversion of the RP to digital converter (after Power On Reset) the switch will be activated regardless of the UNDER_RANGE_SWITCH_EN setting. 2. If RP < 798Ω after the fourth conversion the switch state depends on the setting of UNDER_RANGE_SWITCH_EN. (a) If UNDER_RANGE_SWITCH_EN = 1: The switch will be enabled. (b) If UNDER_RANGE_SWITCH_EN = 0: The previous switch state will be held until the oscillation restarts (RP > 798Ω) and enough time has passed for a conversion to update the switch status. If a temperature conversion has not been completed the switch state will not be changed. The LMP91300 oscillator will begin to oscillate in less than 10 oscillator periods once the low RP condition is removed.

12

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

Feature Description (continued) 7.3.5 Programming The Switching Point And Hysteresis The typical procedure is that the user puts a target metal at the target distance in front of the manufactured sensor system. The PROXIMITY_MSB and Proximity LSB registers are read and the DET_H_MSB and DET_H_ LSB registers are written with a value that causes the LMP91300 to switch. The metal target is then moved to another distance, farther away than the first distance, the PROXIMITY_MSB and Proximity LSB registers are read and a value is written to the DET_L_MSB and DET_L_ LSB registers that causes the LMP91300 to switch the external transistor off. 7.3.6 Temperature Compensation As most of the integrated electronics are in the digital domain, close to perfect performance of the LMP91300 over temperature can be expected. As the RP factor of the external LC tank is measured, only the temperature coefficient of the LC tank losses need to be compensated for. The LMP91300 offers a digital temperature compensation feature that provides an accurate RP detection of the external LC tank when losses are introduced due to ambient temperature changes in the operating environment. This can be done by calibrating the Temperature Look-Up Table (LUT) located in registers 0x00 to 0x5D. The calibration involves the user generating gain correction factor coefficients (GCF) and is discussed in detail in the Look-Up Table Calibration section. These registers hold 2 bytes of information representing temperatures ranging from -48°C to 136°C in 4°C increments. The LMP91300 uses linear interpolation to provide 1°C temperature steps in between these 4°C points to improve accuracy. After the LUT has been properly programmed, the Detection Threshold registers need to be programmed for the switching distances desired. The external temperature sensor and the temperature coefficients stored in the LUT produce a functional temperature compensation system. The LUT was designed for an NTC with a beta factor β = 4250 such as the Murata NCP03WF104F05RL. Any other NTC used in the design will require additional adjustments which are explained in the Look-Up Table Calibration section. 7.3.7 Power Supply An internal regulator with an external NPN transistor is used to power the LMP91300 directly from the loop. 7.3.8 LED Drive An external LED can be driven with the LED terminal. Red and Green LEDs are supported. The LED current can be programmed to 2.5mA or 5 mA. This LED indicates the state of the sensor. Typically the LED is on if the switch is closed, but this is programmable in the OUT_CONFIG_INIT and OUT_CONFIG_FNL registers. This LED will also indicate an output overload condition situation or ECC error. 7.3.9 SWDRV The LMP91300 drives an external transistor, to implement a NPN or PNP function. During power up the drive terminal (SWDRV) is pulled down using a high resistance to avoid turning on the external transistor, until the LMP91300 is fully functional. 7.3.10 Overload Protection Short circuit detection and overload protection are implemented in the LMP91300, using an external SENSE resistor, RSENSE. When the voltage drop across RSENSE exceeds about 310 mV the LMP91300 detects a short circuit condition. If this condition persists, the switch is toggled between being open and closed. The switch will be on for about 30µs, with a duty cycle as set in OUT_CONFIG_INIT (0x72) bit 0 (SHORTCKT_DUTY_CYCLE) or OUT_CONFIG_FNL (0x78) bit 0 (SHORTCKT_DUTY_CYCLE) to protect the external BJT. For example, if SHORTCKT_DUTY_CYCLE is set to 0.1% the switch drive will be on for 30µs and off for 29.97ms (tOFF = (30µs/0.1%) - 30µs). During a short circuit event, the load current is limited to I=480mV/RSENSE. The LMP91300 will come out of the overload protection mode once the drop across RSENSE is less than 310mV.

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

13

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

Feature Description (continued) When designing the overload protection circuitry the user must select the appropriate transistors, SWDRV current setting, RSENSE resistor and short circuit duty cycle. The transistor should be selected to handle the load current and supply voltage both during normal operation and during an overload situation to ensure that it remains in the safe operating region at all times. The RSENSE resistor should be chosen to set the current limit and over current threshold. The SWDRV current should be selected to ensure that during a short circuit condition the SWDRV current is capable of sourcing or sinking the programmed current depending on NPN or PNP configuration. This ensures that the short circuit control loop remains regulated and enforces the current limit and over current threshold. Once overload protection design is complete the user has the option to choose between the two duty cycle options.

7.4 Device Functional Modes NPN and PNP 3 wire configurations as shown in the Typical Application section are supported by the LMP91300.

7.5 Programming Through the 2-wire loop connection, all parameters such as the LUT, operation modes, output modes and detection thresholds can be programmed after the sensor manufacturing process is finished. The LMP91300 is one time programmable in a 3 step process. During the manufacturing process the configuration and calibration data will be written to the device and then a special code will be written that disables communication. 7.5.1 Burning Programmed Values Into The Registers There are three steps to burning values into the registers. 1. Burn the Temperature Look Up Table data (0x00 – 0x5D), initial registers, device information registers, and configuration registers (0x66 – 0x72). (a) Use SWIF to program values into these registers (0x00 – 0x72). (b) Use SWIF to write 0x08 to register 0x7F to permanently burn the values into the registers. (c) Optional: Wait 300ms and read back the status register (0x7E). It should read 0x21 if the registers have been successfully burned. 2. Burn final registers (0x73 – 0x78). (a) Use SWIF to program values into these registers (0x73 – 0x78). (b) Use SWIF to write 0x10 to register 0x7F to permanently burn the values into the registers. (c) Optional: Wait 300ms and read back the status register (0x7E). It should read 0x23 if the registers have been successfully burned. 3. Burn SWIF mode. After the device has been programmed the write function using SWIF needs to be disabled. (a) Read Only. The SWIF write function is disabled but registers can still be read back using SWIF. Use SWIF to write 0x40 to address 0x7F. After the device is power cycled it will be read only. (b) Disabled. The SWIF is completely disabled, both write and read functions are disabled. Use SWIF to write 0x80 to address 0x7F. After the device is power cycled SWIF will be disabled. (c) Optional: Before power cycling the device wait 300ms and read back the status register (0x7E). It should read 0x27 for read only or 0x2F for SWIF disabled. 4. 4. It is possible to combine steps 1 and 2 and burn the Look Up Table, initial registers, device information registers, configuration registers, and final registers (0x00 – 0x78) at one time. (a) Use SWIF to program values into these registers (0x00 – 0x78). (b) Use SWIF to write 0x20 to register 0x7F to permanently burn the values into the registers. (c) Optional: Wait 300ms and read back the status register (0x7E). It should read 0x23 if the registers have been successfully burned.

14

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

Programming (continued) 7.5.2 Single-Wire Interface (SWIF) The LMP91300 uses a bi-directional Single Wire Interface protocol to program and read registers. To communicate with the LMP91300 (slave) through the SWIF interface, the micro controller (master) must transmit (write) data through the DC loop supply voltage that should be set to +8V during programming or communication. This superimposed signal of pulses transitions between 8V and 12V is on top of the +8V DC loop supply voltage. When the master transmits data into the LMP91300 the signal propagates into the SENSE2+ terminal through the supply. The master receives data from the LMP91300 through the LED terminal in the form of alternating current pulses. These current pulses will be 5mA in amplitude. The LED terminal must be connected to ground, either through an LED or directly connected to ground for the LMP91300 to talk to the master. The communication scheme utilizes various pulse width waveforms to represent different symbols as shown in Figure 15. The binary representation of a zero bit is represented by a 25% pulse duty cycle, a one bit is represented by a 75% pulse duty cycle, and idle bit is represented by a 50% duty cycle. All pulses transmitted must fall within the pulse width specifications provided within the electrical characteristics table. ZERO Bit

IDLE Bit

ONE Bit

1 Time Unit

1 Time Unit

1 Time Unit

25% Duty Cycle

50% Duty Cycle

75% Duty Cycle

Figure 15. Single Wire Interface (SWIF) Symbol Diagram The LMP91300 can be programmed at an input transfer bit rate between 1kbps to 10kbps. There is no acknowledge signal during the input data transfer so the master should read back the data to ensure data integrity and a successful data transfer has occurred. A read transaction is executed by the master transmitting data to configure the pointer register resulting in data output transfer by the slave. The LMP91300 transmits read back data at a speed of about 7kbps. 7.5.2.1 Write Operation A frame begins with a minimum of one IDLE bit. To perform a write operation, the master must send an IDLE bit followed by the R/W bit set to 0 and the 7-bit address of the register that is intended to be programmed. The data to be written into the address location follows with the Most Significant Bit first and the write operation is terminated with an IDLE bit. There are 8 bits in each data byte and the maximum number of data bytes can be up to 8 bytes. Data being transmitted from the master to the slave can be terminated by the master by sending an IDLE bit after any data byte. After communication, to initiate another communication, the master must transmit another IDLE. When an invalid bit that violates the SWIF symbol protocol is transferred, the SWIF will reset and wait for the IDLE bit. k: The total number of bytes, k = 8 (max)

Complete frame for a Write Operation 8*k bits 8 bits IDLE

R/W = 0

8 bits

7-bit Address

D7

DATA

C DATA

D0

IDLE

Figure 16. Complete Frame For A Write Command

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

15

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

Programming (continued) 7.5.2.2 Read Operation The read signal is made by modulating the supply current. This can be read by using a SENSE resistor in the supply line. The LMP91300 modulates the supply current by sinking current into the LED terminal. The V+/EXT and LED terminals need to be connected by either an LED, resistor, or directly shorted for the Read operation to work. To perform a read operation, the master must send an IDLE bit to initiate communication, a R/W bit that should be set to 1, a 7-bit address, and another IDLE bit. Data is written back after the R/W and address byte are received so there must be a 9th rising edge to ensure that this condition is satisfied. After the last bit, A0, of the address is sent there should only be one rising edge to perform the IDLE bit. There are two valid methods of providing one rising edge, (1) a single pulse, or (2) a rising edge with the signal held high. See Figure 17 for a timing example of both cases. 9TH Rising Edge

IDLE

IDLE

7-bit Address R/W = 1

A6

A5

A4

A3

A2

A1

A0

(1)

R/W = 1

A6

A5

A4

A3

A2

A1

A0

(2)

End of Read Command: LMP91300 Enters Transmit Mode

Start of Read Command

Figure 17. Read Timing Example: (1) Single Pulse, (2) Hold Signal High After Last Rising Edge The LMP91300 goes into transmit mode 10μs plus a symbol length after the IDLE rising edge and no longer accepts any data until transmission is done. The master is not allowed to send anything until the slave has finished sending the data. Data is always written back on a read command with an IDLE bit, 8 bytes of data, and another IDLE bit. All transmitting is done in 8 byte blocks with the exception that only one byte is transmitted when the STATUS register (0x7E) is read. Since data transfer is always 8 bytes maximum (except for when register 0x7E, STATUS is read), there is a maximum wait time (8 bits*8 bytes + IDLE + IDLE + 10us) that the master must wait before taking ownership of the bus. The amount of time it takes for SWIF to switch from input to output is about one symbol. k: The total number of bytes, k = 8 (max)

Complete frame for a Read Operation 8 bits IDLE

R/W = 1

7-bit Address

Symbol + 10s IDLE

Master Initiates a Read Operation

8*k bits

8 bits IDLE

D7

DATA

D0

C DATA

IDLE

LMP91300 Enters Transmit Mode and Returns DATA

Figure 18. Complete Frame For A Read Command The user has the option to set the LMP91300 into a read-only mode or SWIF disabled mode. When placed in read-only mode, the SWIF can only be used to read back the registers but all write capability is disabled. When placed in SWIF disabled mode, both read and write capabilities are disabled.

16

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

Programming (continued) 7.5.3 Usage Priority Of Registers When a LMP91300 is powered on the register values that are used depends on if the LMP91300 has had values burned into the registers. See register 0x7F, BURN_REQ. 1. No values have been burned into registers: (a) When powered on the LMP91300 will use the default values in registers 0x00-0x5D and 0x66-0x72. (b) If a value is written to any of these registers (0x00-0x5D and 0x66-0x72) the LMP91300 will use the value written instead of the power on default value. (c) If a value is written into a FNL register (0x73-0x78) the LMP91300 will continue to use the value in the INIT register instead of the corresponding FNL register. For example, if register OSC_CONFIG_3_FNL (0x77) has a value written to it, the LMP91300 will continue using the OSC_CONFIG_3_INIT (0x71) register and not use the value in the OSC_CONFIG_3_FNL (0x77) register. (d) If the LMP91300 is powered off and back on it will use the default values in registers 0x00-0x5D and 0x66-0x72. 2. Values have been burned into the LMP91300 memory using burn request 0x08. (a) When powered on the LMP91300 will use the burned values in registers 0x00-0x5D and 0x66-0x72. (b) If a value is written to any of these registers (0x00-0x5D and 0x66-0x72) the LMP91300 will use the written value instead of the burned value. (c) If a value is written into a FNL register (0x73-0x78) the LMP91300 will continue to use the value in the INIT register instead of the corresponding FNL register. For example, if register OSC_CONFIG_3_FNL (0x77) has a value written to it, the LMP91300 will continue using the OSC_CONFIG_3_INIT (0x71) register and not use the value in the OSC_CONFIG_3_FNL (0x77) register. (d) If the LMP91300 is powered off and back on the LMP91300 will use the burned values in registers 0x000x5D and 0x66-0x72. 3. Values have been burned into the LMP91300 memory using burn request 0x10 or 0x20. (a) When powered on the LMP91300 will use the burned values in registers 0x00-0x5D, 0x6A-0x70 and 0x73-0x78. (b) If a value is written to an INIT register (0x66-0x69, 0x71-0x72) it will be ignored and the corresponding FNL register (0x73-0x78) will be used. (c) If a value is written to a FNL register (0x73-0x78) the LMP91300 will use the written value instead of the burned value. (d) If the LMP91300 is powered off and then back on the LMP91300 will use the burned values in registers 0x00-0x5D, 0x6A-0x70 and 0x73-0x78. It is important to remember that the LMP91300 will always use the values in the initial registers (either temporary written values or permanently burned values) if the final registers have not had values burned into them. If the final registers have had values burned into them, the LMP91300 will always use the final registers (either the permanently burned value or a value that has been temporally written in a final register). The burn status of the LMP91300 can be determined by reading the STATUS register (0x7E) as long as a 0x80 burn request has not been issued. Each register can only have a value burned into it one time. It is not possible to burn a value into a register multiple times.

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

17

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

7.6 Register Maps Name

Description

Address

Type

Default

LUT_x_GAIN_MSB, LSB

Temperature Look Up Table, -48°C to +136°C in 4°C steps, 2 bytes - gain

0x00-0x5D

RW

0x40 - even addresses, 0x00 - odd addresses

RESERVED

Reserved

0x5E-0x65

RO

0x00

DET_H_MSB_INIT

Detection High Threshold MSB (Initial)

0x66

RW

0x00

DET_H_LSB_INIT

Detection High Threshold LSB (Initial)

0x67

RW

0x00

DET_L_MSB_INIT

Detection Low Threshold MSB (Initial)

0x68

RW

0x00

DET_L_LSB_INIT

Detection Low Threshold LSB (Initial)

0x69

RW

0x00

INFO0

Device Information 0

0x6A

RW

0x00

INFO1

Device Information 1

0x6B

RW

0x00

INFO2

Device Information 2

0x6C

RW

0x00

INFO3

Device Information 3

0x6D

RW

0x00

OSC_CONFIG_0

Oscillator Configuration 0

0x6E

RW

0x0E

OSC_CONFIG_1

Oscillator Configuration 1

0x6F

RW

0x14

OSC_CONFIG_2

Oscillator Configuration 2

0x70

RW

0x45

OSC_CONFIG_3_INIT

Oscillator Configuration 3 (Initial)

0x71

RW

0x1B

OUT_CONFIG_INIT

Output Configuration (Initial)

0x72

RW

0xA2

DET_H_MSB_FNL

Detection High Threshold MSB (Final)

0x73

RW

0x00

DET_H_LSB_FNL

Detection High Threshold LSB (Final)

0x74

RW

0x00

DET_L_MSB_ FNL

Detection Low Threshold MSB (Final)

0x75

RW

0x00

DET_L_ LSB_ FNL

Detection Low Threshold LSB (Final)

0x76

RW

0x00

OSC_CONFIG_3_FNL

Oscillator Configuration 3 (Final)

0x77

RW

0x1B

OUT_CONFIG_FNL

Output Configuration (Final)

0x78

RW

0xA2

TEMP64

Temperature in °C + 64

0x79

RO

NA

PROXIMITY_MSB

Proximity MSB

0x7A

RO

NA

PROXIMITY_LSB

Proximity LSB

0x7B

RO

NA

RESERVED

Reserved

0x7C-0x7D

RO

0x00

STATUS

Device Status

0x7E

RO

NA

BURN_REQ

Burn Request

0x7F

WO

NA

18

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

Register Maps (continued) DET_H_MSB_INIT – Detection High Threshold MSB (Initial) (Address 0x66) Bit

Name

Function (Default values in bold)

[7:0]

DET_H_MSB_INIT

0x00: Detection High Threshold MSB (Initial)

See the Usage Priority Of Registers section. A starting value to put in the DET_H_MSB_INIT and DET_H_LSB_INIT registers can be determined by first setting the correct values in the OSC_CONFIG_0, OSC_CONFIG_1, OSC_CONFIG_2, OSC_CONFIG_3_INIT, OUT_CONFIG_INIT registers, putting the target at the distance away from the target that it is supposed to switch on at, reading the values in the PROXIMITY_MSB and Proximity LSB registers, and writing these values into the DET_H_MSB_INIT and DET_H_LSB_INIT registers. This value can be then adjusted as needed. DET_H_LSB_INIT – Detection High Threshold LSB (Initial) (Address 0x67) Bit

Name

Function (Default values in bold)

[7:0]

DET_H_LSB_INIT

0x00: Detection High Threshold LSB (Initial)

See the Usage Priority Of Registers section. DET_L_MSB_INIT – Detection Low Threshold MSB (Initial) (Address 0x68) Bit

Name

Function (Default values in bold)

[7:0]

DET_L_MSB_INIT

0x00: Detection Low Threshold MSB (Initial)

See the Usage Priority Of Registers section. A starting value to put in the DET_L_MSB_INIT and DET_L_LSB_INIT registers can be determined by first setting the correct values in the OSC_CONFIG_0, OSC_CONFIG_1, OSC_CONFIG_2, OSC_CONFIG_3_INIT, OUT_CONFIG_INIT registers, putting the target at the distance away from the target that it is supposed to switch off at, reading the values in the PROXIMITY_MSB and Proximity LSB registers, and writing these values into the DET_L_MSB_INIT and DET_L_LSB_INIT registers. This value can be then adjusted as needed. DET_L_LSB_INIT – Detection Low Threshold LSB (Initial) (Address 0x69) Bit

Name

Function (Default values in bold)

[7:0]

DET_L_LSB_INIT

0x00: Detection Low Threshold LSB (Initial)

See the Usage Priority Of Registers section. INFO0 – Device Information 0 (Address 0x6A) Bit

Name

Function (Default values in bold)

[7:0]

INFO0

0x00: Device Information 0

This register can be used to store information such as assembly date, model number, revision number or any other data. INFO1 – Device Information 1 (Address 0x6B) Bit

Name

Function (Default values in bold)

[7:0]

INFO1

0x00: Device Information 1

This register can be used to store information such as assembly date, model number, revision number or any other data.

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

19

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

INFO2 – Device Information 2 (Address 0x6C) Bit

Name

Function (Default values in bold)

[7:0]

INFO2

0x00: Device Information 2

This register can be used to store information such as assembly date, model number, revision number or any other data. INFO3 – Device Information 3 (Address 0x6D) Bit

Name

Function (Default values in bold)

[7:0]

INFO3

0x00: Device Information 3

This register can be used to store information such as assembly date, model number, revision number or any other data. OSC_CONFIG_0 – Oscillator Configuration 0 Register (Address 0x6E) Bit

Name

Function (Default values in bold)

[7:5]

Reserved

000

[4:0]

RP_MAX

01110: Maximum RP, logarithmic scale

The optimal setting for RP_MAX is the highest value for which the correct amplitude is maintained, with the target set at the maximum switching distance. 1. Determine RLCTANK as shown in the Determining The RP of an LC Tank section. 2. Multiply RPLCTANK by 2 and use the next higher value from the chart below. For example, if RPLCTANK measured at 4mm is 11113, 11113x2 = 22226, so 12 (27704) would be used for RP_MAX. 3. This value can be adjusted up or down as needed.

Register Setting (Hex)

RP (Ω)

Register Setting (Hex)

RP (Ω)

Register Setting (Hex)

RP (Ω)

0

3926991

B

193926

16

9235

1

3141593

C

145444

17

7182

2

2243995

D

109083

18

5387

3

1745329

E

83111

19

4309

4

1308997

F

64642

1A

3078

5

981748

10

48481

1B

2394

6

747998

11

38785

1C

1796

7

581776

12

27704

1D

1347

8

436332

13

21547

1E

1026

9

349066

14

16160

1F

798

A

249333

15

12120

20

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

OSC_CONFIG_1 – Oscillator Configuration 1 Register (Address 0x6F) Bit

Name

Function (Default values in bold)

[7:5]

PADC_TIMEC

000: Sensor time constant range

[4:0]

RP_MIN

10100: Minimum RP, logarithmic scale

The PADC_TIMEC (time constant), sets the damping of the readout circuitry. The higher this Parameter is set, the more damping it has. If programmed to zero (0), it has no damping, and the system is almost unstable. The oscillation amplitude (envelope) will vary a lot. If this parameter is set to max (7), the damping is maximum, but that also means the response becomes slow. The optimal setting is what in control theory is called "critical damping", that is the least damping required to prevent overshoot in the step response. In most cases set PADC_TIMEC = 1. The optimal setting for RP_MIN is the highest value for which the correct amplitude is maintained, with the target at the minimum switching distance. Some margin is given to the value. 1. Determine RPLCTANK as shown in the Determining The RP of an LC Tank section. 2. Divide the RPLCTANK value by 2 and then select the next lower RP value from the chart above. For example, if the finished Proximity Sensor is to detect at 4mm and the RPLCTANK measured at 4mm is 11113, 11113/2 = 5556.5, so 18 (5387) would be used for RP_MIN. 3. This value can be adjusted up or down as needed. OSC_CONFIG_2 – Oscillator Configuration 2 Register (Address 0x70) Bit

Name

Function (Default values in bold)

[7:0]

RESONATOR_MIN_FREQ

01000101: Minimum frequency setting, logarithmic scale

Determine the minimum oscillation frequency (fMIN) of the LC tank. This is when there is no target in front of the LC tank. Calculate a value 20% below the minimum oscillation frequency, f80% = fMIN x 0.8. Use the following formula to calculate the value for RESONATOR_MIN_FREQ:

f80% 2000 255 × log 5000 log

(1)

Take this value, round up to the next integer and convert to hex.

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

21

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

OSC_CONFIG_3_INIT – Oscillator Configuration 3 Register (Initial) (Address 0x71) Bit

Name

Function (Default values in bold)

[7:6]

RESERVED

00

[5]

UNDER_RANGE_SWITCH_EN

0: Off 1: On

[4:3]

OSC_AMP

00: 1V 01: 2V 10: 4V 11: Reserved

[2:0]

RESPONSE_TIME

000: Reserved 001: 96 010: 192 011: 384 100: 768 101: 1536 110: 3072 111: 6144

See the Usage Priority Of Registers section. UNDER_RANGE_SWITCH_EN: The following applies if at least one temperature conversion has been completed: 1. If RP < 798Ω (for example, the metal plate is against the sensor) before the fourth conversion of the RP to digital converter (after Power On Reset) the switch will be activated regardless of the UNDER_RANGE_SWITCH_EN setting. 2. If RP < 798Ω after the fourth conversion the switch state depends on the setting of UNDER_RANGE_SWITCH_EN. (a) If UNDER_RANGE_SWITCH_EN = 1: The switch will be enabled. (b) If UNDER_RANGE_SWITCH_EN = 0: The previous switch state will be held until the oscillation restarts (RP > 798Ω) and enough time has passed for a conversion to update the switch status. If a temperature conversion has not been completed the switch state will not be changed. OSC_AMP: The oscillation amplitude at terminals INA and INB can be set to 1V, 2V, or 4V. If the LMP91300 has not been burned with user values, the power on value for OSC_AMP is 11: Reserved. This will need to be changed to either 1V, 2V or 4V before the LMP91300 is used. RESPONSE_TIME: Using a lower response time will shorten the settling time of the digital filter and give faster readings from the RP to digital converter but will increase the noise in the reading. A higher setting gives the digital filter more time to settle and will decrease the noise in the reading.

22

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

OUT_CONFIG_INIT – Output Configuration Register (Initial) (Address 0x72) Bit

Name

Function (Default values in bold)

[7:6]

SWDRV_CURRENT

00: 2.5mA 01: 3.75mA 10: 5mA 11: 10mA

5

OUTPUT_MODE

0: 3-Wire NPN 1: 3-Wire PNP

4

DRIVE_MODE

0: Normally open 1: Normally closed

3

LED_ENABLE

0: On 1: Off

2

LED_MODE

0: Normally off 1: Normally on

1

LED_CURRENT

0: 2.5mA 1: 5mA

0

SHORTCKT_DUTY_CYCLE

0: 0.1% 1: 0.8%

See the Usage Priority Of Registers section. SWDRV_CURRENT: Used to set the amplitude of current from the SWDRV terminal used to control the external transistor. DRIVE_MODE: Normally open and normally closed refer to the external NPN or PNP switch when a target is far away from the inductive sensor. When the switch is normally open the transistor is not conducting when the target is far away from the target (the distance is greater than the value in DET_L_MSB and DET_L_ LSB). The switch is conducting when the target is close to the sensor (the distance is less than the value in DET_H_MSB and DET_H_ LSB). When the switch is normally closed the transistor is conducting when the target is far away from the target (the distance is greater than the value in DET_L_MSB and DET_L_ LSB). The switch is not conducting when the target is close to the sensor (the distance is less than the value in DET_H_MSB and DET_H_ LSB). LED_ENABLE: When set to On the LED will function as set in Bit 2, LED_MODE. When set to Off the LED will always be off. LED_MODE: Normally off means that the LED is off when the target is far away from the sensor (the distance is greater than the value in DET_L_MSB and DET_L_ LSB). The LED will turn on when the target is close (the distance is less than the value in DET_H_MSB and DET_H_ LSB). Normally on means that the LED is on when the target is far away from the sensor (the distance is greater than the value in DET_L_MSB and DET_L_ LSB). ). The LED will turn off when the target is close (the distance is less than the value in DET_H_MSB and DET_H_ LSB). LED_CURRENT: Sets the current through the LED. SHORTCKT_DUTY_CYCLE: When the LMP91300 is in overload protection mode it will test to determine if the overload condition is still present. The switch will be on for about 30µs, with an on to off duty cycle as set by SHORTCKT_DUTY_CYCLE to protect the external BJT. For example, if SHORTCKT_DUTY_CYCLE is set to 0.1% the switch drive will be on for 30µs and off for 29.97ms (tOFF = (30µs/0.1%) - 30µs).

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

23

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

DET_H_MSB_FNL – Detection High Threshold MSB (Final) (Address 0x73) Bit

Name

Function (Default values in bold)

[7:0]

DET_H_MSB_FNL

0x00: Detection High Threshold MSB (Final)

See the Usage Priority Of Registers section. A starting value to put in the DET_H_MSB_FNL and DET_H_LSB_FNL registers can be determined by first setting the correct values in the OSC_CONFIG_0, OSC_CONFIG_1, OSC_CONFIG_2, OSC_CONFIG_3_INIT/FNL, OUT_CONFIG_INIT/FNL registers, putting the target at the distance away from the target that it is supposed to switch on at, reading the values in the PROXIMITY_MSB and Proximity LSB registers, and writing these values into the DET_H_MSB_INIT/FNL and DET_H_LSB_INIT/FNL registers. This value can be then adjusted as needed. DET_H_LSB_FNL – Detection High Threshold LSB (Final) (Address 0x74) Bit

Name

Function (Default values in bold)

[7:0]

DET_H_LSB_FNL

0x00: Detection High Threshold LSB (Final)

See the Usage Priority Of Registers section. DET_L_MSB_FNL – Detection Low Threshold MSB (Final) (Address 0x75) Bit

Name

Function (Default values in bold)

[7:0]

DET_L_MSB_FNL

0x00: Detection Low Threshold MSB (Final)

See the Usage Priority Of Registers section. A starting value to put in the DET_L_MSB_FNL and DET_L_LSB_FNL registers can be determined by first setting the correct values in the OSC_CONFIG_0, OSC_CONFIG_1, OSC_CONFIG_2, OSC_CONFIG_3_INIT/FNL, OUT_CONFIG_INIT/FNL registers, putting the target at the distance away from the target that it is supposed to switch off at, reading the values in the PROXIMITY_MSB and Proximity LSB registers, and writing these values into the DET_L_MSB_INIT/FNL and DET_L_LSB_INIT/FNL registers. This value can be then adjusted as needed. DET_L_LSB_FNL – Detection Low Threshold LSB (Final) (Address 0x76) Bit

Name

Function (Default values in bold)

[7:0]

DET_L_LSB_FNL

0x00: Detection Low Threshold LSB (Final)

See the Usage Priority Of Registers section.

24

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

OSC_CONFIG_3_FNL – Oscillator Configuration 3 Register (Final) (Address 0x77) Bit

Name

Function (Default values in bold)

[7:6]

RESERVED

00

[5]

UNDER_RANGE_SWITCH_EN

0: Off 1: On

[4:3]

OSC_AMP

00: 1V 01: 2V 10: 4V 11: Reserved

[2:0]

RESPONSE_TIME

000: Reserved 001: 96 010: 192 011: 384 100: 768 101: 1536 110: 3072 111: 6144

See the Usage Priority Of Registers section. UNDER_RANGE_SWITCH_EN: The following applies if at least one temperature conversion has been completed: 1. If RP < 798Ω (for example, the metal plate is against the sensor) before the fourth conversion of the RP to digital converter (after Power On Reset) the switch will be activated regardless of the UNDER_RANGE_SWITCH_EN setting. 2. If RP < 798Ω after the fourth conversion the switch state depends on the setting of UNDER_RANGE_SWITCH_EN. (a) If UNDER_RANGE_SWITCH_EN = 1: The switch will be enabled. (b) If UNDER_RANGE_SWITCH_EN = 0: The previous switch state will be held until the oscillation restarts (RP > 798Ω) and enough time has passed for a conversion to update the switch status. If a temperature conversion has not been completed the switch state will not be changed. OSC_AMP: The oscillation amplitude at terminals INA and INB can be set to 1V, 2V, or 4V. If the LMP91300 has not been burned with user values, the power on value for OSC_AMP is 11: Reserved. This will need to be changed to either 1V, 2V or 4V before the LMP91300 is used. RESPONSE_TIME: Using a lower response time will shorten the settling time of the digital filter and give faster readings from the RP to digital converter but will increase the noise in the reading. A higher setting gives the digital filter more time to settle and will decrease the noise in the reading.

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

25

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

OUT_CONFIG_FNL – Output Configuration Register (Final) (Address 0x78) Bit

Name

Function (Default values in bold)

[7:6]

SWDRV_CURRENT

00: 2.5mA 01: 3.75mA 10: 5mA 11: 10mA

5

OUTPUT_MODE

0: 3-Wire NPN 1: 3-Wire PNP

4

DRIVE_MODE

0: Normally open 1: Normally closed

3

LED_ENABLE

0: On 1: Off

2

LED_MODE

0: Normally off 1: Normally on

1

LED_CURRENT

0: 2.5mA 1: 5mA

0

SHORTCKT_DUTY_CYCLE

0: 0.1% 1: 0.8%

See the Usage Priority Of Registers section. SWDRV_CURRENT: Used to set the amplitude of current from the SWDRV terminal used to control the external transistor. DRIVE_MODE: Normally open and normally closed refer to the external NPN or PNP switch when a target is far away from the inductive sensor. When the switch is normally open the transistor is not conducting when the target is far away from the target (the distance is greater than the value in DET_L_MSB and DET_L_ LSB). The switch is conducting when the target is close to the sensor (the distance is less than the value in DET_H_MSB and DET_H_ LSB). When the switch is normally closed the transistor is conducting when the target is far away from the target (the distance is greater than the value in DET_L_MSB and DET_L_ LSB). The switch is not conducting when the target is close to the sensor (the distance is less than the value in DET_H_MSB and DET_H_ LSB). LED_ENABLE: When set to On the LED will function as set in Bit 2, LED_MODE. When set to Off the LED will always be off. LED_MODE: Normally off means that the LED is off when the target is far away from the sensor (the distance is greater than the value in DET_L_MSB and DET_L_ LSB). The LED will turn on when the target is close (the distance is less than the value in DET_H_MSB and DET_H_ LSB). Normally on means that the LED is on when the target is far away from the sensor (the distance is greater than the value in DET_L_MSB and DET_L_ LSB). ). The LED will turn off when the target is close (the distance is less than the value in DET_H_MSB and DET_H_ LSB). LED_CURRENT: Sets the current through the LED. SHORTCKT_DUTY_CYCLE: When the LMP91300 is in overload protection mode it will test to determine if the overload condition is still present. The switch will be on for about 30µs, with an on to off duty cycle as set by SHORTCKT_DUTY_CYCLE to protect the external BJT. For example, if SHORTCKT_DUTY_CYCLE is set to 0.1% the switch drive will be on for 30µs and off for 29.97ms (tOFF = (30µs/0.1%) - 30µs).

26

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

TEMP64 – Temperature In °C + 64 (Address 0x79) Bit

Name

Function (Default values in bold)

[7:0]

TEMP64

Temperature in °C + 64

Convert the value read from this register to decimal and subtract 64 to determine the temperature in °C. PROXIMITY_MSB – Proximity MSB (Address 0x7A) Bit

Name

Function (Default values in bold)

[7:0]

PROXIMITY_MSB

Proximity MSB

When a command is issued to read the PROXIMITY_MSB register, values from the RP to Digital converter are placed in the PROXIMITY_MSB and Proximity LSB registers. The value in the Proximity LSB register will not change until another read command of PROXIMITY_MSB is given. It is recommended that both the PROXIMITY_MSB and Proximity LSB registers be read together. PROXIMITY_LSB – Proximity LSB (Address 0x7B) Bit

Name

Function (Default values in bold)

[7:0]

Proximity LSB

Proximity LSB

Bit

Name

Function (Default values in bold)

7

PADC_TIMEOUT

0: No timeout 1: Timeout

6

ECC_ERR

0: No error 1: Error

5

BUSY

0: Part is busy 1: Part is not busy

4

BURN_PROG

0: No burn in progress 1: Burn in progress

[3:0]

SWIF_STATUS

0x0: No burn has occurred, full SWIF access 0x1: Addresses 0x00 to 0x72 burned, full SWIF access 0x3: Addresses 0x00 to 0x78 burned, full SWIF access 0x7: Addresses 0x00 to 0x78 burned, SWIF is read only 0xF: Addresses 0x00 to 0x78 burned, SWIF is disabled

STATUS – Device Status (Address 0x7E)

When register 0x7E is read only one byte of data is transmitted from the LMP91300. BURN_REQ – Burn Request (Address 0x7F) Bit

Name

Function (Default values in bold)

[7:0]

BURN_REQ

0x08: Burn Temperature Look Up Table data (0x00 – 0x5D), initial registers, device information registers, and configuration registers (0x66 – 0x72). 0x10: Burn final registers (0x73 – 0x78). 0x20: Burn all registers (0x00 – 0x78). 0x40: Set SWIF to read back mode. 0x80: Disable SWIF.

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

27

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

8 Application and Implementation 8.1 Application Information The LMP91300 is a complete analog front end (AFE) optimized for use in inductive proximity sensors. The LMP91300 detects the presence of a metal object based on the RP change of an LC oscillator, depending on the distance of the metal object. The LMP91300 can be used in 3 wire NPN or PNP inductive sensors.

8.2 Typical Application 6.5V to 40V C1 REXT B

CFB

LED

CFA CF

EXT B

CV+/EXT E V+/EXT E SENSE1+ SENSE2+

Load

SWDRV +

INA LMP91300

SENSE-

INB CBY

RSENSE TEMP+ NTC

GND CBY

3-Wire NPN

Figure 19. 3-Wire NPN Configuration 6.5V to 40V

REXT B

C1 RSENSE

+

R1

-

CFB

LED

CFA CF

EXT B

CV+/EXT E Load V+/EXT E SWDRV

INA

LMP91300 SENSE1+ INB

NTC

CBY

TEMP+

SENSE2+ GND SENSECBY

3-Wire PNP

Figure 20. 3-Wire PNP Configuration For operation above 40V a series resistance must be added to SENSE1+ and SENSE2+. The mismatch in these resistors will affect the overload protection accuracy for the PNP configuration. These resistors must be chosen so that the SENSE1+ and SENSE2+ terminals do not operate above 40V. 28

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

Typical Application (continued) 8.2.1 Design Requirements 1. Loop Voltage: 6.5V to 40V 2. LC Tank Oscillation Frequency: 0.005MHz to 5MHz 3. LC Tank RP: 798Ω to 3.93MΩ 8.2.2 Detailed Design Procedure 8.2.2.1 Quick Start When a new sensor is being used the registers should be setup using the following procedure. Instructions on how to determine the value to put in each register are described in the Register Maps section. 1. Set RP_MAX in the OSC_CONFIG_0 register. 2. Set PADC_TIMEC and RP_MIN in the OSC_CONFIG_1 register. 3. Set RESONATOR_MIN_FREQ in the OSC_CONFIG_2 register. 4. Set UNDER_RANGE_SWITCH_EN, OSC_AMP, and RESPONSE_TIME in the OSC_CONFIG_3_INIT and OSC_CONFIG_3_FNL registers. The same values should be written to both registers. Setting OSC_AMP to 4V and RESPONSE_TIME to 6144 should give the most accurate results. Note that the power on default for OSC_AMP is 11:Reserved so OSC_AMP must be changed to either 1V, 2V, or 4V. 5. Select the value of the CF capacitor as described in the CF (CFA and CFB Terminals) section. 6. Set the values in the OUT_CONFIG_INIT and OUT_CONFIG_FNL registers as needed. The same values should be written to both registers. 7. Put the sensor at the target distance that the switch is supposed to turn on. Read the PROXIMITY_MSB and Proximity LSB multiple times. If needed, RP_MAX or RP_MIN can be adjusted up or down one step at a time to determine the combination that gives the most accurate setting for this specific sensor. 8. Put the sensor at the target distance that the switch is supposed to turn on. Read the PROXIMITY_MSB and Proximity LSB multiple times, take an average, and write this value into the DET_H_MSB_INIT and DET_H_LSB_INIT and DET_H_MSB_FNL and DET_H_LSB_FNL registers. This value may need to be adjusted. 9. Put the sensor at the target distance that the switch is supposed to turn off. Read the PROXIMITY_MSB and Proximity LSB multiple times, take an average, and write this value into the DET_L_MSB_INIT and DET_L_LSB_INIT and DET_L_MSB_FNL and DET_L_LSB_FNL registers. This value may need to be adjusted. 8.2.2.2 Determining The RP of an LC Tank The method in the Quick Start section for setting the values in the LMP91300 registers requires that the RP of the LC tank be known at the switching point (the point that the switch is changed from the normal condition to the triggered condition). It is best to use an impedance analyzer to characterize the RP of the LC tank over distance. If an impedance analyzer is not available the RP of the LC tank can be determined using the method below. 1. Set the target at the switching distance from the sensor. 2. Set PADC_TIMEC = 1, RESONATOR_MIN_FREQ as described in the Register Maps section, OSC_AMP = 4V, and RESPONSE_TIME = 6144. 3. Put a scope probe on INA or INB. 4. Step RP_MIN up one step at a time until the amplitude of the signal on the oscilloscope becomes variable as shown in Figure 21 and Figure 22. Increase RP_MIN by two, for example if the amplitude becomes variable at 17, set RP_MIN to 19. 5. Step RP_MAX up one step at a time until the amplitude of the signal on the oscilloscope becomes steady. Decrease RP_MAX by two steps, for example if amplitude became steady at 16, set RP_MAX to 14. 6. Set the CF capacitor as described in the CF (CFA and CFB Terminals) section. 7. Read the Proximity value in registers 0x7A and 0x7B and convert this value to decimal. 8. Use the formula RPLCTANK (Ω) = (RP_MAX × RP_MIN ) / ( RP_MIN × (1-Y) + RP_MAX × Y ), where Y = Proximity Data / 2^15 and RP_MAX and RP_MIN are the impedance values shown in Register Maps section. This value can have a tolerance of ±25% when compared to the value from an impedance analyzer. Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

29

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

Typical Application (continued) 8.2.2.3 Component Selection And Layout The following PCB layout guidelines and suggested components should be used when designing a PCB. 8.2.2.4 CF (CFA and CFB Terminals) 10pF to 100nF, ≥10V, X7R ceramic capacitor. The traces connecting CFA and CFB to the capacitor should be as short as possible to minimize the parasitic capacitance. The value of this capacitor will be based on the time constant and resonating frequency of the LC tank. For optimal performance, the value of CF, needs to be as small as possible, but large enough such that the active filter does not saturate. The size of this capacitor depends on the time constant of the SENSE coil, which is given by L/RS, (L = inductance, RS = series resistance of the inductor at oscillation frequency). The larger this time constant becomes, the larger the value of filter capacitor that is required. Hence, this time constant reaches its maximum when there is no target present in front of the sensing coil. The following procedure can be used to determine CF: 1. Start with a default value of 10nF for CF. 2. Set RP_MAX, PADC_TIMEC, RP_MIN, RESONATOR_MIN_FREQ, OSC_AMP, and RESPONSE_TIME to the desired values as described in the Register Maps section. 3. Move the metal target far away from the LC tank. 4. Connect a scope probe to the INB (terminal 21) and CFB (terminal 17) terminals. Since the CFB terminal is very sensitive to capacitive loading, it is recommended to use an active probe. As an alternative, a passive probe with a 1kΩ series resistance between the tip and the CFB terminal can be used. 5. Set the time scale of the oscilloscope so that many periods of the signal on the INA terminal can be seen. See Figure 21. 6. Set the CF capacitor value so that the AC portion of the waveform is about 1VPP maximum. Decreasing the capacitor value will make the AC portion of the waveform larger. This signal scales linearly with the reciprocal of the filter capacitance. For example, if a 100pF filter capacitor is used and the signal observed on the CFB terminal has a peak-to-peak value of 200mV, the desired 1V peak-to-peak value is obtained using a 200mV / 1V × 100pF = 20pF filter capacitor. Figure 21 shows the waveforms on CFB and INA and Figure 22 shows the waveforms using a zoomed in horizontal scale. Note that the waveforms on CFB and INA are not a constant amplitude. The waveform on CFB should be adjusted so that the maximum value is 1VPP.

CFB

1 V/DIV

INA

1 V/DIV

50 µs/DIV

Figure 21. Determining the Value of CF

30

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

Typical Application (continued)

CFB

1 V/DIV

INA

1 V/DIV

20 µs/DIV

Figure 22. Determining the Value of CF 8.2.2.5 NTC (TEMP+ Terminal) The thermistor, such as the Murata NCP03WF104F05RL, should be placed as close to the LC tank as possible to minimize error introduced by temperature variation within the operating environment. The NTC should also be close to the LMP91300 to minimize the parasitic capacitance. It is connected between terminals 22 and 23. There should be a ground trace separating the thermistor from the LC tank, to minimize the coupling from the signal on the LC tank. Ideally, the thermistor could be on one side of the PCB and the LC tank on the other side of the PCB with a ground plane between them. 8.2.2.6 C1 0.1µF to 1µF, ≥50V, X7R ceramic capacitor. This is a bypass capacitor for the regulator. The value of this capacitor will also affect the rising and falling edges of the SWIF signal. A good value to start with is 0.1µF. 8.2.2.7 CV+/EXT

E

100nF, ≥10V, X7R ceramic capacitor. If the loop voltage is ≤ 8V, 100nF is the maximum value that can be used. 8.2.2.8 CBY (CBY Terminal) 56nF, ≥5V, X7R ceramic capacitor. Connect between the CBY terminal and ground. 8.2.2.9 RSENSE The value of this resistor and power rating of the RSENSE resistor depends on the amount of current allowed through the switch transistor. The LMP91300 has an Over Current Detection Threshold of 310mV typical. When the LMP91300 detects ≥ 310mV across the sense resistor it will go into Overload Protection mode. In this mode it will periodically turn on the switch for 30µs to check if the overload condition is still there. If the LMP91300 detects a value ≥ 310mV (typical) across the sense resistor it will limit the current through the switch so that the voltage across RSENSE is ≤ 480mV. See the OVERLOAD PROTECTION entries in the ELECTRICAL CHARACTERISTICS section and Figure 7, Figure 12, and Figure 13. 8.2.2.10 REXT B (EXT B Terminal): The internal regulator along with the external NPN transistor will develop 5V on the V+/EXT E terminal. The EXT B terminal will be one diode drop above this at about 5.6V. The voltage across REXT B will be the difference between the loop voltage and the 5.6V on the EXT B terminal. The value of REXT B depends on the minimum loop voltage and the minimum temperature that the LMP91300 will be used at. The values shown in Figure 23 show the largest typical value for REXT B that can be used for a specific minimum loop voltage and minimum temperature. For example, if the LMP91300 is being used in a proximity sensor that has a specification of 10V

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

31

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

Typical Application (continued) minimum for the loop voltage and an operating temperature minimum of 0°C, a value of 26kΩ or smaller can be used for REXT B. The data shown in Figure 23 depends on several variables, such as the external transistor used and the value of CV+/EXT E. A SMBTA06 transistor was used when taking the data in Figure 23. The user must ensure that the resistor has the correct power rating and that the regulated 5V on the V+/EXT E terminal comes up correctly and is stable for the entire loop voltage and temperature range in the intended application. 60

REXT B Max (kŸ)

50

40 30 20

-40ƒC -20ƒC

10

0ƒC 0 5

10

15

20

25

30

35

40

Loop Voltage (V) C001

Figure 23. Maximum REXT B Value 8.2.2.11 R1 33kΩ, 1/8W resistor. 8.2.2.12 SENSE1+ And SENSE2+ Terminals (RSENSE1+, RSENSE2+) If the supply is ≤ 40V these terminals can be shorted to the supply. If the supply is > 40V resistors must be placed between the SENSE1+ and SENSE2+ terminals and the supply. These resistors must drop enough voltage so that the terminals of the LMP91300 are < 40V. The resistors will have 100µA going through them. For example, if the supply is at 50V, 10V will need to be dropped across these resistors so the resistance will be 10V/100µV = 100kΩ. These resistors must be matched resistors, 0.1% or better. Keep the trace between the LMP91300 and the resistors short. In NPN mode the SENSE1+ terminal is not used. It should be connected to the supply as described above. 8.2.2.13 NPN A SMBTA06 or similar transistor. 8.2.2.14 PNP A FMMT593 or similar transistor. 8.2.2.15 LED The LMP91300 can be programmed to supply 2.5 or 5mA. The LED chosen should have a voltage drop of less than 3V. If an LED is not needed the LED terminal can be connected directly to the V+/EXT E terminal. The LMP91300 uses the LED terminal to talk back to the device controlling the SWIF interface by sinking current into the LED terminal.

32

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

Typical Application (continued) 8.2.2.16 LC Tank and INA and INB Terminals There should be a ground trace between the INA and INB terminals and the rest of the terminals of the LMP91300 to decrease the coupling of the signal on the INA and INB terminals to the other terminals of the LMP91300. The trace between the LC tank and the INA and INB terminals should be as short as possible as shown in part A of Figure 24. Longer traces between the LC tank and the INA and INB terminals can cause ringing at the INA and INB terminals which can produce very noisy proximity readings. If longer traces need to be used split the LC tank so that the capacitor is close to the LMP91300 as shown in part B of Figure 24. If both the L an C have to be located a longer distance away from the LMP91300 small capacitors (15 to 22pF) can be connected between INA and ground and INB and ground as shown in part C of Figure 24. Short Traces

L

Long Traces

INA LMP91300

C

Short Traces

L

C

INB

A

Long Traces

INA LMP91300

L

INA LMP91300

C

INB

INB

B

C

Figure 24. LC Tank Traces 8.2.2.17 SWDRV Terminal Keep the trace between the SWDRV terminal and the transistor short. 8.2.2.18 P1 To P5 Terminals Connect to ground using short traces. 8.2.2.19 GND Terminals Connect to ground using short traces. 8.2.2.20 NC Terminals These terminals do not connect to the silicon and can be left unconnected. 8.2.2.21 Exposed DAP Connect to ground. The DAP area on the PCB can be used as the center of a star ground with all other ground terminals connecting to it. 8.2.2.22 SENSEIn PNP mode the SENSE- terminal is not used. It should be connected to ground. 8.2.3 Look-Up Table Calibration 1. RP Measurement: Take RP measurements by reading the Proximity registers 0x7A and 0x7B from the lowest temperature of interest to the highest temperature within the predefined LUT values. The temperature range should fall within the LUT preset values of -48°C to 136°C in 4°C increments. Convert all the measured values from hex to decimal. (a) Proximity measurements at all temperatures between -48°C to 136°C will give the most accurate results. If the proximity measurement at some temperatures are skipped a value will need to be interpolated from the measured values. This is described in step 4. (b) To avoid uncertain conditions outside the temperature range of interest the user should duplicate the same value of RP for the temperature below and above those limits. For example, if the lowest temperature that a proximity measurement was made was -28°C, this value should be used for all lower temperatures. The same applies at the high temperature range of the LUT. Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

33

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

Typical Application (continued) 2. Temperature Correlation: For every RP measurement the temperature register TEMP64 (0x79) should be read to ensure that the ambient temperature correlates to the intended LUT preset temperature. The TEMP64 register is an 8 bit unsigned register that contains the temperature (in °C) + 64. Any discrepancy between ambient temperature and preset LUT temperature during calibration will result in a temperature calibration error. 3. Normalizing RP: Once all RP values have been read and logged for the whole LUT temperature range as illustrated in Figure 25 the data must be normalized to the intended ambient operating temperature T0. This is done by dividing each RP data point by R0, the measured RP at the ambient operating temperature for each temperature of the LUT register. This ratio provides the gain correction factor coefficients (GCF) as shown in Figure 26. If the ambient operating temperature T0 does not fall on one of the 4°C incremental points of the LUT then R0 will need to be interpolated.

RP

T0: Temperature of operating environment R0: RP at operating environment

R-1 R0 R1

-48°C

-44°C

-40°C

T-1

T0

T1 128°C

132°C

136°C

Temperature Figure 25. RP Measurement Example

GCF

GCF-1 =

R-1 R0

GCF1 =

R1 R0

T0: Temperature of operating environment GCF0: Normalized to 1 at operating environment

1

-48°C

-44°C

-40°C

T-1

T0

T1 128°C

132°C

136°C

Temperature Figure 26. GCF Normalized Example 4. Interpolating GCF values that have not been measured: Plot the measured GCF values vs temperature and then make a polynomial trend line of the data. Use the formula of the trend line to determine the GCF values for all temperatures that were not measured. 5. LUT Data Entry: Each GCF needs to be converted from decimal to a 16 bit binary word representing a decimal number between 0 and 4. An example illustrating this binary representation of the decimal number is shown in Figure 27. The conversion equation that scales the GCF into the 16 bit binary GCFBINARY is shown in Equation 2. Once the conversion has been calculated for each temperature the values are programmed 34

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

Typical Application (continued) into the appropriate registers in the LUT. The MSB of the LUT value consists of bits D15 to D8 as shown in Figure 27, the LSB are bits D7 to D0.

D15

D14

D13

D12

D7

D6

D5

D4

D3

D2

D1

D0

Decimal Representation

Figure 27. Binary Representation Of Gain Correction Factor

GCFBINARY = GCF ×

216 4

(2)

6. NTCs with a β ≠ 4250: The temperature LUT has been internally hard coded based on a specific NTC with a β factor of 4250 (Murata NCP03WF104F05RL). The user must recalibrate the LUT when an NTC with a β factor other than 4250 is used. The LUT temperature range is extended past the LMP91300 operating range to facilitate recalibrating the LUT if using other off the shelf NTC components. The process for using a NTC that has β ≠ 4250 is as follows: (a) Put the finished system including the LC tank, NTC and LMP91300 into a temperature chamber. (b) Set the temperature of the chamber to a value, for this example we will use -40°C. (c) Read the temperature from register 0x79. For this example we will use -44°C. (d) Follow the process above to determine the gain. (e) The gain value will go into the -44°C position of the LUT. (f) Connect terminals P1 - P5 to ground using short traces. (g) Connect the Ground terminal to the main ground point using short traces.

9 Power Supply Recommendations An internal voltage regulator allows the LMP91300 to operate with a supply from 6.5V to 40V. The values of C1 and CV+/EXT E must be chosen as described in the Detailed Design Procedure section.

10 Layout 10.1 Layout Guidelines • •



• •

The traces connecting pins CFA and CFB to the CF capacitor should be as short as possible to minimize the parasitic capacitance. The NTC should be placed as close to the LC tank as possible to minimize error introduced by temperature variation within the operating environment. The NTC should also be close to the LMP91300 to minimize the parasitic capacitance. There should be a ground trace separating the thermistor from the LC tank, to minimize the coupling from the signal on the LC tank. Ideally, the thermistor could be on one side of the PCB and the LC tank on the other side of the PCB with a ground plane between them. There should be a ground trace between the INA and INB terminals and the rest of the terminals of the LMP91300 to decrease the coupling of the signal on the INA and INB terminals to the other terminals of the LMP91300. The trace between the LC tank and the INA and INB terminals should be as short as possible as shown in part A of Figure 24. Longer traces between the LC tank and the INA and INB terminals can cause ringing at the INA and INB terminals which can produce very noisy proximity readings. If longer traces need to be used split the LC tank so that the capacitor is close to the LMP91300 as shown in part B of Figure 24. If both the L an C have to be located a longer distance away from the LMP91300 small capacitors (15 to 22pF) can be connected between INA and ground and INB and ground as shown in part C of Figure 24. Keep the trace between the SWDRV terminal and the transistor short. The DAP area on the PCB can be used as the center of a star ground with all other ground terminals connecting to it.

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

35

LMP91300 SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

www.ti.com

10.2 Layout Example

Top Layer

NTC

LMP91300

RSENSE REXT B

NPN

R1 C1

Bottom Layer

LC Tank

CF CBY

CV+/EXT E

NPN

PNP

LED

Figure 28. LMP91300 PNP Layout Example

36

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

LMP91300 www.ti.com

SNOSCS3B – SEPTEMBER 2013 – REVISED MARCH 2014

11 Device and Documentation Support 11.1 Trademarks All trademarks are the property of their respective owners.

11.2 Electrostatic Discharge Caution These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates.

11.3 Glossary SLYZ022 — TI Glossary. This glossary lists and explains terms, acronyms and definitions.

12 Mechanical, Packaging, and Orderable Information The following pages include mechanical packaging and orderable information. This information is the most current data available for the designated devices. This data is subject to change without notice and revision of this document. For browser-based versions of this data sheet, refer to the left-hand navigation.

Submit Documentation Feedback

Copyright © 2013–2014, Texas Instruments Incorporated

Product Folder Links: LMP91300

37

PACKAGE OPTION ADDENDUM

www.ti.com

6-Feb-2014

PACKAGING INFORMATION Orderable Device

Status (1)

Package Type Package Pins Package Drawing Qty

Eco Plan

Lead/Ball Finish

MSL Peak Temp

(2)

(6)

(3)

Op Temp (°C)

Device Marking (4/5)

LMP91300NHZJ

ACTIVE

WQFN

NHZ

24

4500

Green (RoHS & no Sb/Br)

CU SN

Level-3-260C-168 HR

-40 to 125

L91300

LMP91300NHZR

ACTIVE

WQFN

NHZ

24

1000

Green (RoHS & no Sb/Br)

CU SN

Level-3-260C-168 HR

-40 to 125

L91300

LMP91300NHZT

ACTIVE

WQFN

NHZ

24

250

Green (RoHS & no Sb/Br)

CU SN

Level-3-260C-168 HR

-40 to 125

L91300

LMP91300YZRR

ACTIVE

DSBGA

YZR

20

3000

Green (RoHS & no Sb/Br)

SNAGCU

Level-1-260C-UNLIM

-40 to 125

ATAA

LMP91300YZRT

ACTIVE

DSBGA

YZR

20

250

Green (RoHS & no Sb/Br)

SNAGCU

Level-1-260C-UNLIM

-40 to 125

ATAA

(1)

The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2)

Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3)

MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.

(4)

There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device.

(5)

Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation of the previous line and the two combined represent the entire Device Marking for that device.

Addendum-Page 1

Samples

PACKAGE OPTION ADDENDUM

www.ti.com

6-Feb-2014

(6)

Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish value exceeds the maximum column width. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.

Addendum-Page 2

PACKAGE MATERIALS INFORMATION www.ti.com

14-Nov-2014

TAPE AND REEL INFORMATION

*All dimensions are nominal

Device

Package Package Pins Type Drawing

SPQ

Reel Reel A0 Diameter Width (mm) (mm) W1 (mm)

B0 (mm)

K0 (mm)

P1 (mm)

W Pin1 (mm) Quadrant

LMP91300NHZJ

WQFN

NHZ

24

4500

330.0

12.4

4.3

5.3

1.3

8.0

12.0

Q1

LMP91300NHZR

WQFN

NHZ

24

1000

178.0

12.4

4.3

5.3

1.3

8.0

12.0

Q1

LMP91300NHZT

WQFN

NHZ

24

250

178.0

12.4

4.3

5.3

1.3

8.0

12.0

Q1

LMP91300YZRR

DSBGA

YZR

20

3000

178.0

8.4

2.31

2.88

0.76

4.0

8.0

Q1

Pack Materials-Page 1

PACKAGE MATERIALS INFORMATION www.ti.com

14-Nov-2014

*All dimensions are nominal

Device

Package Type

Package Drawing

Pins

SPQ

Length (mm)

Width (mm)

Height (mm)

LMP91300NHZJ

WQFN

NHZ

24

4500

367.0

367.0

35.0

LMP91300NHZR

WQFN

NHZ

24

1000

213.0

191.0

55.0

LMP91300NHZT

WQFN

NHZ

24

250

213.0

191.0

55.0

LMP91300YZRR

DSBGA

YZR

20

3000

210.0

185.0

35.0

Pack Materials-Page 2

MECHANICAL DATA

NHZ0024B

SQA24B (Rev A)

www.ti.com

MECHANICAL DATA

YZR0020xxx

0.600±0.075

D

E

TLA20XXX (Rev D)

D: Max = 2.706 mm, Min =2.646 mm E: Max = 2.084 mm, Min =2.024 mm

4215053/A NOTES:

A. All linear dimensions are in millimeters. Dimensioning and tolerancing per ASME Y14.5M-1994. B. This drawing is subject to change without notice.

www.ti.com

12/12

IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily performed. TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components in safety-critical applications. In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and requirements. Nonetheless, such components are subject to these terms. No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties have executed a special agreement specifically governing such use. Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of non-designated products, TI will not be responsible for any failure to meet ISO/TS16949. Products

Applications

Audio

www.ti.com/audio

Automotive and Transportation

www.ti.com/automotive

Amplifiers

amplifier.ti.com

Communications and Telecom

www.ti.com/communications

Data Converters

dataconverter.ti.com

Computers and Peripherals

www.ti.com/computers

DLP® Products

www.dlp.com

Consumer Electronics

www.ti.com/consumer-apps

DSP

dsp.ti.com

Energy and Lighting

www.ti.com/energy

Clocks and Timers

www.ti.com/clocks

Industrial

www.ti.com/industrial

Interface

interface.ti.com

Medical

www.ti.com/medical

Logic

logic.ti.com

Security

www.ti.com/security

Power Mgmt

power.ti.com

Space, Avionics and Defense

www.ti.com/space-avionics-defense

Microcontrollers

microcontroller.ti.com

Video and Imaging

www.ti.com/video

RFID

www.ti-rfid.com

OMAP Applications Processors

www.ti.com/omap

TI E2E Community

e2e.ti.com

Wireless Connectivity

www.ti.com/wirelessconnectivity Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2014, Texas Instruments Incorporated