Micrologic Control Trip Units Functions and Characteristics
±
L
So ±
Compact NSX MCCB
Micrologic Control Trip Units Functions and Characteristics
I ±
±
L
S ±
I ±
G ±
Remark: For Micrologic 2.2-AB (protection of public distribution system), 2.2-G (for generator), 5.2 A-Z and 6 E-M, please consult Schneider Electric (HK) Ltd. Micrologic 2.2-AB ( ), 2.2-G ( ), 5.2 A-Z 6 E-M
Compact NSX MCCB Trip Units
L
So ±
I ±
L
S ±
I ±
Compact NSX MCCB Trip Units
G ±
Compact NSX/NS/ Compact NSX/NS/NSD CVS MCCB MCCB Functions and Characteristics Functions and Characteristics
Compact NS (800A-1600A) MCCB
Compact NS (800A-1600A) Micrologic Control Units MCCB Micrologic Control Units
±
±
±
±
±
±
± ±
±
±
t
t
Ir
tr
Ir
Isd tr
0
I
Isd I
0
t
Ir tr
t
Ir
Isd tsd
tr
Ii Isd
I
0 tsd Ii I
0
t
2
I t on
Ig 2
tg
t
I t off
2
I t on
Ig
0
2
tg
0
I t off
I
t
I
I!n t!n
t
I!n
0 t!n
0
I
I
Compact NS (800A-1600A) MCCB Micrologic Control Units
Micrologic 6.0 A
Micrologic 2.0
9 10 !t= I!n= tsd= tr= Isd= Ii= Ir= Ig= tg=
MAX s kA
11
100 % 12
40 % 1
13
menu
2 1
4
long time
Ir
1
.7 .6 .5 .4
tr 8 (s) 4 .9 12 16 .95 2 .98 1 20 24 1 .5
.8
x In
3
Isd 4 3 5 2.5 6 2 8 1.5 10 x Ir
tsd (s)
.4 .4 .3
.3 .2 .1
on
setting
Ig
5
5
D C B A
E
7
@ 6 Ir
short time
3
2
alarm
ground fault
.2 .1
0 off
delay
tg
F G H J
2
I t
Ii
(s)
on
2
I t
4 3
6 8 10 12 15 off 2 x In test
.4 .4 .3
.3 .2 .1
instantaneous
.2 .
0 off
4 6 8
Compact NSX MCCB
Vigi Earth-leakage Protection Module
25ºC
25ºC
Compact NS MCCB
Catalogue Number
Compact NSX MCCB Catalogue Number
Advanced electronic trip unit Micrologic 6.2 E-M (LSIG motor protection & energy meter) for NSX100 - 250 Micrologic 6.2 E-M (LSIG ) NSX100 - 250 To be ordered with 2 catalogue numbers: 1 basic frame + 1 trip unit Advanced electronic trip unit Micrologic 6.3 E-M (LSIG protection & energy meter) for NSX400 - 630 Micrologic 6.3 E-M (LSIG ) NSX400 - 630 To be ordered with 2 catalogue numbers: 1 basic frame + 1 trip unit
Compact NSX MCCB Catalogue Number
Compact NSX MCCB Catalogue Number
Advanced electronic trip unit with built-in energy meter and LSI protection (Micrologic 5.2 E & 5.3E) for NSX100 - 630 series (Micrologic 5.2 E & 5.3E) NSX100 - 630 To be ordered with 2 catalogue numbers: 1 basic frame + 1 trip unit Advanced electronic trip unit with built-in ammeter meter and LSIG protection (Micrologic 6.2 A & 6.3A) for NSX100 - 630 series (Micrologic 6.2 A & 6.3A) NSX100 - 630 To be ordered with 2 catalogue numbers: 1 basic frame + 1 trip unit Advanced electronic trip unit with built-in energy meter and LSIG protection (Micrologic 6.2 E & 6.3E) for NSX100 - 630 series (Micrologic 6.2 E & 6.3E) NSX100 - 630 To be ordered with 2 catalogue numbers: 1 basic frame + 1 trip unit
Compact NSX MCCB Accessories
Compact NSX MCCB Accessories
Compact NSX MCCB Accessories
L= 0.35 m L= 1.3 m
LV434200 LV434201
L= 3 m for U>480VAC L= 0.35 m BSCM - Breaker Status Control Module
LV434202 LV434204 LV434205
FDM121 Front Display Module (96 x 96mm) FDM121 mounting accessory(diameter = 22mm) Modbus interface communication module External Power Supply module
TRV00121 TRV00128 TRV00210 ABL8MEM24012
NSX Cord (including internal terminal block)
Stacking connectors RJ45/RJ45 male cord
10 L=0.3 m L=0.6 m L=1 m L=2 m
10 10 5 5
L=3 m L=5 m
5 1 10 10
RJ45 connectors female/female ULP line terminator (1) NSX Maintenance case USB maintenance interface ULP setting tool Pocket battery for Micrologic NSX100-630
(1) Modbus network (2) Modbus interface communication module (3) + (4) NSX Cord (5) BSCM (6) Prefabricated wiring (7) Micrologic trip unit (8) FDM121 display (9) RJ45 cable (10) ULP line terminator (11) External power supply 220V AC/ 24V DC