SIMATIC PCS 7 Process Control System. E86060-K4678-A121-A7-7600.
SIMATIC. ST 70. Products for. Totally Integrated Automation and Micro
Automation.
© Siemens AG 2009
Migration solutions with the SIMATIC PCS 7 Process Control System Catalog ST PCS 7.2 • October 2009
SIMATIC PCS 7 Answers for industry.
© Siemens AG 2009
Related catalogs SIMATIC SIMATIC PCS 7 Process Control System
ST PCS 7
SITRAIN Training for Automation and Industrial Solutions
E86060-K4678-A111-B4-7600
E86060-K6850-A101-B9
SIMATIC ST PCS 7.1 Add Ons for the SIMATIC PCS 7 Process Control System
Interactive Catalog CA 01 Products for Automation and Drives
E86060-K4678-A121-A7-7600
E86060-D4001-A500-C8-7600
SIMATIC Products for Totally Integrated Automation and Micro Automation
ST 70
E86060-K4670-A101-B2-7600 SIMATIC HMI Human Machine Interfaces
ST 80
E86060-K4680-A101-B6-7600 SIMATIC NET Industrial Communication
IK PI
E86060-K6710-A101-B6-7600 TELEPERM M AS 488/TM Automation systems
PLT 112
Only PDF (E86060-W3812-A100-A3-7600) Process Automation Field instruments for Process Automation
E86060-K6201-A101-B1-7600
FI 01
Industry Mall Information and ordering platform in the Internet: www.siemens.com/industrymall
ITC
CA 01
© Siemens AG 2009
SIMATIC PCS 7 Migration solutions with the SIMATIC PCS 7 Process Control System
Introduction
1
TELEPERM M migration
2
APACS+/QUADLOG migration
3
SIMATIC PCS / TISTAR migration
4
OpenPMC migration
5
Bailey INFI 90/NET 90 migration
6
Honeywell TDC migration
7
ABB Contronic P migration
8
Invensys Triconex connection
9
The products contained in this catalog can also be found in the e-Catalog CA 01. Order No.: E86060-D4001-A500-C8-7600 Please contact your local Siemens branch © Siemens AG 2009
Systems from other vendors
Supersedes: Catalog ST PCS 7.2 · July 2007
Other solutions
The products and systems described in this catalog are manufactured/distributed under application of a certified quality management system in accordance with DIN EN ISO 9001 (Certified Registration No. 1323-QM). The certificate is recognized by all IQNet countries.
Systems from Siemens
Catalog ST PCS 7.2 · October 2009
Integration of third-party controllers using PCS 7/OPEN OS
10
Integration of FOUNDATION Fieldbus
11
Appendix
12
© Siemens AG 2009
1/2
Siemens ST PCS 7.2 · October 2008
© Siemens AG 2009
Answers for industry.
Siemens Industry answers the challenges in the manufacturing and the process industry as well as in the building automation business. Our drive and automation solutions based on Totally Integrated Automation (TIA) and Totally Integrated Power (TIP) are employed in all kinds of industry. In the manufacturing and the process industry. In industrial as well as in functional buildings.
Siemens offers automation, drive, and low-voltage switching technology as well as industrial software from standard products up to entire industry solutions. The industry software enables our industry customers to optimize the entire value chain – from product design and development through manufacture and sales up to after-sales service. Our electrical and mechanical components offer integrated technologies for the entire drive train – from couplings to gear units, from motors to control and drive solutions for all engineering industries. Our technology platform TIP offers robust solutions for power distribution.
The high quality of our products sets industry-wide benchmarks. High environmental aims are part of our eco-management, and we implement these aims consistently. Right from product design, possible effects on the environment are examined. Hence many of our products and systems are RoHS compliant (Restriction of Hazardous Substances). As a matter of course, our production sites are certified according to DIN EN ISO 14001, but to us, environmental protection also means most efficient utilization of valuable resources. The best example are our energy-efficient drives with energy savings up to 60 %.
Check out the opportunities our automation and drive solutions provide. And discover how you can sustainably enhance your competitive edge with us.
Siemens ST PCS 7.2 · October 2008
1/3
© Siemens AG 2009
ERP – Enterprise Resource Planning
Management Level
MES – Manufacturing Execution Systems
Operations Level
SIMATIC PCS 7 Process Control (DCS)
Industrial Software for • Design and Engineering • Installation and Commissioning • Operation
• Maintenance • Modernization and Upgrade • Energy Management
Control Level SIMOTION Motion Control System
SINUMERIK Computer Numeric Control
Field Level PROFIBUS PA
02.03.2009
Process Instrumentation
Totally Integrated Automation
SIMATIC Sensors
HART IO-Link
Setting standards in productivity and competitiveness. Totally Integrated Automation.
Thanks to Totally Integrated Automation, Siemens is the only provider of an integrated basis for implementation of customized automation solutions – in all industries from inbound to outbound.
1/4
Siemens ST PCS 7.2 · October 2008
© Siemens AG 2009
Ethernet
SIMATIC IT
Ethernet SIMATIC WinCC SCADA System
Industrial Ethernet Industrial Ethernet
SIMATIC NET Industrial Communication
SIMATIC Controllers Modular/Embedded/ PC-based
SIMATIC HMI Human Machine Interface
Safety Integrated Low-Voltage Controls and Distribution
PROFINET
SIMATIC Distributed I/O
SINAMICS Drive Systems
PROFIsafe
Industrial Ethernet
PROFIsafe
PROFIBUS
ASIsafe
AS-Interface
Totally Integrated Power KNX GAMMA instabus
TIA is characterized by its unique continuity. It provides maximum transparency at all levels with reduced interfacing requirements – covering the field level, production control level, up to the corporate management level. With TIA you also profit throughout the complete life cycle of your plant – starting with the initial planning steps through operation up to modernization, where we offer a high measure of investment security resulting from continuity in the further development of our products and from reducing the number of interfaces to a minimum.
The unique continuity is already a defined characteristic at the development stage of our products and systems. The result: maximum interoperability – covering the controller, HMI, drives, up to the process control system. This reduces the complexity of the automation solution in your plant. You will experience this, for example, in the engineering phase of the automation solution in the form of reduced time requirements and cost, or during operation using the continuous diagnostics facilities of Totally Integrated Automation for increasing the availability of your plant.
Siemens ST PCS 7.2 · October 2008
1/5
© Siemens AG 2009
Integrated power distribution from one source. Totally Integrated Power.
1/6
Siemens ST PCS 7.2 · October 2008
© Siemens AG 2009
Communication IEC 61850
PROFINET
BACnet
Industrial Ethernet PROFIBUS Processes / industrial automation
KNX EIB
Products and systems Medium voltage
Transformers
Low voltage
Installation technology
Building automation
≤ 110 kV
03.04.2008
Planning and system configuration
Electrical power distribution in buildings requires integrated solutions. Our response: Totally Integrated Power. This means innovative and integrated, interface-optimized products and systems which have been optimally coordinated and complemented with communication and software modules that link power distribution to building automation or industrial automation. Totally Integrated Power accompanies power distribution projects from one end to the other. From A to Z. From the planning to the building’s use: Totally Integrated Power offers significant advantages in every project stage and to everyone involved in the project – the investors, electrical planning engineers, electricians, users and building facility managers.
Our portfolio comprises everything from engineering tools to the matching hardware: from switchgear and distribution systems for medium voltage to transformers, from switching and circuit-protection devices to low-voltage switchgear and busbar trunking systems, as far as to the small distribution board and the wall outlet. It goes without saying that both the medium-voltage switchgear, which requires no maintenance, and the low-voltage switchgear are type-tested, and their busbar connections, too. Comprehensive protection systems ensure the safety of man and machine at any time.
Siemens ST PCS 7.2 · October 2008
1/7
© Siemens AG 2009
SIMATIC PCS 7 process control system If a company wishes to strengthen its position in the market, it is essential to react flexibly and rapidly to new market requirements, while keeping interruptions in current operation down to a minimum. This is the strength of the SIMATIC PCS 7 process control system from Siemens. As a corner pillar of the Totally Integrated Automation concept, SIMATIC PCS 7 constitutes a uniform complete system which surpasses the capabilities of previous systems and satisfies all demands placed on the process control technology – one control system for all industries and applications.
With SIMATIC PCS 7 we are committed to expanding the competitive advantages of customers throughout the complete lifecycle of their industrial plants. The SIMATIC PCS 7 process control system provides advantages in the areas of: - Integration - Performance - Scalability - Modernization - Security - Innovation - Global network of experts
1/8
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Siemens has been offering a wide range of innovative migration products and solutions for its globally proven systems for many years already. Right from the beginning, the maxim of Siemens' migration strategy is to modernize the existing installed basis in steps and without completely changing the system – if possible without a plant shutdown or with minimum production downtimes. Siemens therefore supports customers' endeavors to achieve long-term safeguarding of investments together with maximization of their return on assets.
Siemens ST PCS 7.2 · October 2009
1/9
© Siemens AG 2009
Siemens Migration Strategy System Aspects
Plant Aspects
Production Aspects
HMI/batch - Replaces old HMI - Replaces batch system
Innovation pressure - Improved process control - IT integration - Advanced process control & asset management
Strategy - Plant/product future - Planned modernization (revamping)
Controller/network - Replaces controller - Gateway to SIMATIC PCS 7 I/O field connection - Further use of I/Os - Field connection elements for SIMATIC PCS 7
Stepwise
Lifecycle phases - Maintenance & modernization - Expansion & improvement - Renewal/replacement with state-of-the-art technology
Adaptable
Cost reduction - Maintenance budget - Investment budget Time-to-Market - Production time - Available downtime
Flexible
Innovative Technologies
Migration strategy Globalization and incessantly increasing competitive pressures are forcing companies to continuously increase productivity and shorten product time to market. To this end, it is necessary to continuously optimize engineering procedures and the process, and to simultaneously consider new industrial requirements and directives.
Experience has shown that the success of migration is largely determined by providing a technical solution that optimally matches the customer requirements and the customer’s plant. Minimization of the technical and financial risks together with safeguarding of investments for as long a period as possible are always fundamental aspects.
Therefore Siemens does not consider its task to simply be the complete replacement of an existing system, but in close collaboration together with customers and their system integrators of an individual, future-oriented solution based on the state-of-the-art SIMATIC PCS 7 process control system - always under the directives:
Today, many systems and plants must be expanded and modernized to ensure that companies can continue to provide products meeting market requirements. However, since the installed basis of hardware, application software and know-how of the operating and maintenance engineers represents an enormous value, the safeguarding of investments for companies operating the plants is always assigned a high priority during all modernization plans.
The different lifecycles of the various system components must also be considered, which currently vary from 5 years for PC-based workstations, 15 years for controllers, up to 25 years or more for input/output components and wiring.
• Step-by-step system innovation
1/10
Siemens ST PCS 7.2 · October 2009
• Adaptable to the specific conditions of the plant • Flexible according to production requirements
© Siemens AG 2009
Legacy system
SIMATIC PCS 7
Migration services in every step of migration project
OS
Engineering Station
Controller
Importing of engineering data of old OS OS replacement by server for PCS 7/OS
Clients
Server
S7-400 S7-400 H S7-400 FH controller
Gateway to Gateway data coupling
Importing of controller engineering
Engineering System
Server
PROFIBUS PA
I/O
Linking of existing I/O modules to PCS 7/AS
I/O interface
Field Termination Adapter
Motor
PROFIBUS DP ET 200M
Wiring rack
Step-by-step migration with the right products and services
Portfolio of the migration products Siemens already recognized the significance of migration for process automation at an early point in time, and has offered a wide range of innovative migration products and solutions for its globally proven systems for many years already. Through consistent extension of this migration offering Siemens has become more and more capable of also modernizing legacy systems from other manufacturers with SIMATIC PCS 7. Right from the start, the principle of Siemens' migration strategy is to modernize the existing installed base step-by-step without completely changing the system – if possible without a plant shutdown or with minimum production downtimes. In this manner, Siemens supports customers' endeavors to achieve long-term safeguarding of investments and maximize return on assets.
products and technologies which are even more efficient. A good example of this principle is "Database Automation" (DBA). Using DBA and a plug-in interface, it is possible to download configuration data and to display and configure it using a standardized user interface.
Siemens' expertise in the migration sector has continuously grown. The experience gained in numerous migration projects has been incorporated into new
The migration products can be categorized as follows:
Migration component
Description
OS migration products
• • •
Interface from SIMATIC PCS 7 OS Server to system bus of old system OS conversion tool (e.g. DBA) Faceplate library
Services for OS migration
Tools/services for conversion of process pictures
Services for AS migration
Tools/services for function-based conversion of AS engineering data to SIMATIC PCS 7
BATCH migration components
Enables existing systems to use SIMATIC BATCH
Gateway
• •
Data Base Automation
Thus DBA enables system-supported migration of uniform operator system data from different output systems. The results are uniform software quality, security, and traceability.
Reuse of old system I/Os or Field Termination Assembly (FTA)
• •
Gateway between system bus of old system and SIMATIC PCS 7 (mainly for AS-AS communication) Engineering tool for gateway Reuse of I/Os (connection of old I/Os to SIMATIC PCS 7 automation systems, mostly for Siemens systems) Field Termination Assemblies (FTAs) for field cabling
Siemens ST PCS 7.2 · October 2009
1/11
© Siemens AG 2009
Typical migration scenarios The migration path that a user opts for depends on the specific technical and economic factors of each migration project. The migration products offer the modularity and flexibility required to implement different scenarios. Typical migration scenarios which can be implemented using these migration products are described below:
Scenario 1: Replacement of existing HMI system by a SIMATIC PCS 7 operator system
Scenario 2: Expansion of existing plant
Scenario 3: Comprehensive modernization
If the HMI (Human Machine Interface) system is technically obsolete, if the stocking of spare parts is too expensive, if it no longer complies with current directives and standards for operator workstations, or if functional expansions are required (e.g. IT integration), it is possible to simply replace the existing HMI system with a SIMATIC PCS 7 operator system. The controller with application software and the process I/O are retained.
The existing plant is initially retained, and is modernized by expanding with further sections/units with SIMATIC PCS 7.
Bottlenecks in the provision of spare parts, insufficient support, and the necessity for functional expansions (e.g. fieldbus technology or IT integration) can also force comprehensive modernization of the old system using the future-oriented SIMATIC PCS 7 process control system. Conversion may also be possible during operation. Further use of the existing I/O level is supported, and the investments made for wiring, hardware components or application engineering are safeguarded.
Advantages of this migration step:
Advantages of this migration step:
Advantages of this migration step:
• Minimum costs
• Simple, step-by-step increase in production capacity
• Increase in performance
• Clear risk • Clear risk • Lengthening of service life of the entire plant
• Introduction of new technologies (e.g. PROFIBUS fieldbus, HMI)
• New application possibilities • Opening of system for IT world
• Introduction of new technologies (e.g. PROFIBUS fieldbus, HMI) • Opening of system for IT world • Lengthening of service life of the entire plant
• Opening of system for IT world • Together with scenario 1, enables process control using a uniform operator system
• Reduction in number of system suppliers • Elimination of bottlenecks
1/12
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
SIMATIC PCS 7 OS clients
PCS 7/TM OS ES
CS 275
PCS 7/ APACS+ OS
SIMATIC PCS 7 Engineering
PCS 7/505 OS
4-mation
APT
H1 TF
MBUS
PCS 7/ OPMC OS
SIMATIC PCS 7 OS clients
PCS 7 OS server
PCS 7/90 OS
PCS 7/ third-party OS
SIMATIC IT Management Console
Ethernet S7417H
OpenPMC Controller
S7-41x
Bailey Plant Loop/ INFI-NET
Third-party control system
SIMATIC PCS 7
Bailey Infi/Net 90
Other systems
AS 235
TELEPERM M
APACS+/ QUADLOG
SIMATIC PCS/TISTAR
Migration spectrum The migration of own process control systems to SIMATIC PCS 7 is a matter of course for Siemens, and a significant component of the continued supplier/customer relationship. Siemens is additionally able to offer migration solutions for process control systems from other vendors, e.g. for systems from ABB, Bailey or Honeywell. Siemens works closely with the customer's system integrators when implementing migration projects, for they have the know-how gained over many years and exactly know the plant as well as the customer's requirements. This partnership is a guarantee for the companies operating plants that they will receive an optimum migration solution. A further important aspect is that Siemens supports the migration products as well as the standard products by means of product updating and customer support. A special strength of Siemens compared to other suppliers of migration solutions is the ability to offer customers long-term support through know-how, servicing and provision of components, spare parts and upgrades.
OpenPMC
With the future-oriented SIMATIC PCS 7 process control system, innovative migration solutions and services, many years of know-how in process automation and migration, as well as continuous worldwide servicing, Siemens demonstrates its expertise and offers the security of a reliable partner. Migration Support Center Siemens has established several Migration Support Centers which offer customers further support for migration projects in addition to product support:
Development of further migration products and tools Through the development of flexible migration solutions and services, comprehensive sector know-how, migration experience developed over many years, and worldwide support, Siemens has laid the foundation for the development of migration solutions for third-party control systems. This allows users of third-party control systems to take advantage of the globally leading SIMATIC technology in order to safeguard their investments in new automation engineering for the future.
• Migration concepts • Quotation preparation • Engineering/project management
Siemens ST PCS 7.2 · October 2009
1/13
© Siemens AG 2009
1/14
Siemens ST PCS 7.2 · October 2009
2
© Siemens AG 2009
TELEPERM M migration 2/2
Introduction
2/4
Automation
2/5 2/5
Operator control and monitoring PCS 7/TM OS
2/10 2/10
Engineering PROGRAF AS
2/13 2/13 2/15
Communication CS 275 GT104CS gateway
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
TELEPERM M migration Introduction
■ Overview Engineering system
SIMATIC PCS 7 OS clients
2 PCS 7/TM OS server
PCS 7/TM OS server
CS 275 (single/redundant)
(dualchannel)
PCS 7 OS server
Industrial Ethernet (single/redundant)
Gateway
AS 414 / AS 416 / AS 417 ET 200M
ET 200M ET 200M
DP/PA link
PROFIBUS AS 235 cabinet
AS 488 S cabinet with MIG II migration rack
AS 414/AS 416/AS 417 TM-EA in TELEPERM M cabinet
Field devices
Configuration example for the migration from TELEPERM M to SIMATIC PCS 7
The TELEPERM M process control system from Siemens has proven itself worldwide in many different industry sectors in the past 25 years. More than 15 000 installed systems have proven their performance, reliability and user-friendliness in many years of service, even under extreme operating conditions. The installed platform of the old process control system represents an immense investment in hardware and application software as well as a wealth of valuable and complex know-how accumulated by operating and maintenance personnel. However, many users are now faced with the need to adapt their production operations to market requirements, which means having to expand or modernize their plants. SIMATIC PCS 7, the modern process control system, offers new plants and plant expansions an open platform for modern, forward-looking and economical automation solutions in all industries.
The objective of the migration is to modernize the existing platform step-by-step without changing the system, and at the same time to guarantee past investments for as long as possible. For this purpose, Siemens has been offering optimized migration solutions for the transition from TELEPERM M to SIMATIC PCS 7 for a number of years already. The range of migration products covers hardware and software components as well as services for converting application software, on-site conversions, and the migration of complete systems. At the beginning, TELEPERM M customers primarily chose the step-by-step modernization and functional expansion of individual components of the existing systems: • Replacement of existing automation systems by future-compatible automation systems under the premise of importing existing application software and I/O from TELEPERM M. • Replacement of operation and monitoring systems by operator systems on the basis of SIMATIC PCS 7 • Integration of the distributed SIMATIC process I/Os Nowadays, direct migration of TELEPERM M to SIMATIC PCS 7 is dominant. Customers are committing totally to the SIMATIC system components that have been proven worldwide. They therefore profit on the one hand from the valuable properties of a modern process control system and the synergy effects provided by Totally Integrated Automation (TIA). Siemens supports this trend by means of attractive migration products and optimized services for hardware and software conversion.
2/2
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
TELEPERM M migration Introduction
■ Options Migration services For a migration project to succeed it is not enough just to have a technical solution that is optimally adapted to the customer’s needs and the individual conditions of the plant in question. Equally important is the fast and punctual implementation of this solution at a high level of quality. This is where we support you optionally by means of: • Services for individual phases of the migration process, e.g. AS conversion with retention of the I/Os or substitution of the operator systems including conversion of the user software. • Complete migration of your plant as a service from a single source Our migration specialists have extensive knowledge of the systems technology behind TELEPERM M and SIMATIC PCS 7 and many years of experience in engineering, commissioning and service. They will analyze your plant, inform and advise you individually about the migration options and finally draw up a detailed quotation for your migration project. Short stoppage times call for exact planning, which is why our migration specialists join you in organizing and coordinating the smooth performance of all the activities itemized in the quotation. The user software represents a large portion of the total investment and know-how. Hence the quality of its conversion into the new system world is a key criterion for the migration’s economic efficiency.
TELEPERM M Manual Collection The TELEPERM M Manual Collection is available on CD. Updated manuals of current migration products are provided as electronic documentation together with the respective product. In addition, they can also be downloaded from the Internet via "SIMATIC Guide Manuals" (see under "SIMATIC PCS 7 Process Control System" under the heading "Migration"): www.siemens.com/simatic-docu
■ Ordering data
Order No.
TELEPERM M Manual Collection Electronic manuals on CD, in 2 languages (German, English)
6DL5 900-8AX03-8YX8
C)
C) Subject to export regulations: AL: N, ECCN: 5D992
■ More information You can find detailed information, technical specifications and ordering data for individual TELEPERM M migration products in the following sections: "Automation", "Engineering", "HMI" and "Communication". For supplementary products, refer also to Catalog ST PCS 7.1 (Add-ons for the SIMATIC PCS 7 Process Control System). You can find additional information in the Internet at: http://www.siemens.com/teleperm
In the course of the migration we provide you with fast and reliable conversion of your user software for use on the new SIMATIC PCS 7 system platform. In doing so we make allowance for sector-specific properties as well as special plant solutions. The modern tools that we have developed give you the benefit of consistent quality, reliability and verifiability. All the conversion steps performed are documented, as are the manual reconfigurations occasionally required. Finally, we will draw up detailed documentation of your plant as soon as the re-start is completed. We even see to the proper disposal of any replaced system components. For information, consulting, analysis and a quotation, please contact your local Siemens representative.
Siemens ST PCS 7.2 · October 2009
2/3
2
© Siemens AG 2009
TELEPERM M migration Automation
■ Overview
2
The migration package PCS 7/TM-EA, which combines a SIMATIC PCS 7 automation system with the components required for the connection to the TELEPERM-E/A distributed I/O in one migration carrier MIG II, and the associated conversion services offered for it have facilitated the gradual changeover from the TELEPERM-E/A I/O to the distributed SIMATIC PCS 7 process I/O since 1999. If you assume that the process I/O of a process cell, including transmitters and actuators, should function for at least 10 years without a new loopcheck, then the preservation of the TELEPERM-I/O in an upcoming migration project appears less attractive today than in the past. With a view to the discontinuation of the TELEPERM-I/O products announced for 2014, we therefore now recommend that you give immediate priority during plant modernization to the complete replacement of existing TELEPERM M automation systems and I/Os with corresponding SIMATIC PCS 7 system components and new software.
2/4
Siemens ST PCS 7.2 · October 2009
For this reason, the different versions of the PCS 7/TM-EA migration package (AS 414-3 TM-EA, AS 416-2 TM-EA, AS 416-3 TM-EA and AS 417-4 TM-EA) are no longer offered as standard products in the current Catalog ST PCS 7.2. The PCS 7/TM-EA migration packages and their individual components, however, remain available in order that migration projects based on PCS 7/TM-EA that have already started can be completed or that the stocks of spare parts for plants already migrated with PCS 7/TM-EA can be built up. SIMATIC PCS 7 system components suitable for plant modernization can be found in the chapters "Automation Systems" and "Process I/O" of the ST PCS 7 Catalog.
© Siemens AG 2009
TELEPERM M migration Operator control and monitoring PCS 7/TM OS
■ Overview
■ Design SIMATIC PCS 7 Industrial Workstation V7.1 OS Clients Engineering Station
Terminal bus PCS 7/TM-OS Server Plus: - PCS 7 OS Software Server or OS Software Redundant Server Pack - Coupling Package PCS 7/TM-OS Option: PCS 7/TM-OCX (NORA)
Hardware platform: SIMATIC PCS 7 Industrial Workstation, Server
Plant bus CS 275
AS 23x
AS x88
The PCS7/TM-OS operator systems offered in this catalog can be used for the migration of older operator systems of TELEPERM M. This is simply done by replacing the OS 252, OS 26x or OS 52x operator systems already installed in existing TELEPERM M process cells/units with the SIMATIC PCS 7 operator systems, which are designed for connection to the TELEPERM M plant bus CS 275.
■ Application The PCS 7/TM-OS operator system with dual-channel functionality, which is designed to be operated simultaneously on the TELEPERM M CS 275 plant bus and the PCS 7 Industrial Ethernet plant bus, can be used in combination with the GT104CS gateway (see section on "Communication") to effectively link existing TELEPERM M process cells to SIMATIC PCS 7 process cells. The cross-bus communication load can be skillfully shared with this combination: • The PCS 7/TM-OS operator system with dual-channel functionality handles - AS-OS communication with the automation systems on the CS 275 and Industrial Ethernet plant buses, as well as - time-of-day synchronization for the TELEPERM M unit • The GT104CS gateway permits cross-bus AS-AS communication.
The SIMATIC PCS 7 industrial workstations V7.1 with basic communication Ethernet (BCE) and the Windows XP Professional/Server 2003 operating system from the SIMATIC PCS 7 Catalog ST PCS 7 can be used as basic hardware for • PCS 7/TM-OS single stations (single station systems) • PCS 7/TM-OS servers and clients (multi-user systems) They can be expanded depending on their use and on the defined scope of delivery by means of: • SIMATIC PCS 7 OS software V7.1 • Components for connecting to the TELEPERM M CS 275 plant bus (interface module, local bus connecting cable and PCS 7/TM-OS coupling package) • Signal module • PCS 7/TM-OCX (NORA) V4.1 program package Furthermore, supplementary/expansion components such as network cables, keyboards, multi-monitor graphics cards, process monitors, redundant terminal bus adapters or smart card readers from the Section "SIMATIC PCS 7 Industrial Workstation" of the current SIMATIC PCS 7 Catalog ST PCS 7 are relevant for the configuration of PCS 7/TM-OS Components from the section "Redundant Operator Systems" in the "Operator System" chapter of the same catalog can also be used. Dual-channel operation The SIMATIC PCS 7 Industrial Workstation with BCE, server version, with its associated expansion components typical for servers, already meets all the requirements for dual-channel operation of the PCS 7/TM-OS. Interfacing to the SIMATIC PCS 7 Industrial Ethernet plant bus can also be implemented via CP 1613 A2 as an alternative to BCE communication. The interfacing via CP 1613 A2 is only required for communication with more than 8 automation systems and when using redundant automation systems. SIMATIC PCS 7 Industrial Workstations with BCE communication can be subsequently upgraded to CP 1613 communication. To this end, in addition to the CP 1613 A2 module, they require either the S7-1613 communication software or S7-REDCONNECT. In contrast to the S7-1613, the S7-REDCONNECT communication software also supports communication with redundant automation systems. For additional information, refer to Catalog ST PCS 7, Chapter "Operator System", Section "Redundant Operator Systems".
The PCS7/TM-OS operator systems can be used as display and control components for the following TELEPERM M automation systems: • AS 215 • AS 230, AS 230 K • AS 235, AS 235 K, AS 235 H • AS 388/TM and AS 488/TM • SIMATIC S5-150U/S5-155U on the CS 275 plant bus
Siemens ST PCS 7.2 · October 2009
2/5
2
© Siemens AG 2009
TELEPERM M migration Operator control and monitoring PCS 7/TM OS PCS 7/TM-OCX (NORA) V4.1 program package
■ Function PCS 7/TM-OS V4.1 coupling package
2
The "PCS 7/TM-OS coupling package for AS 23x/AS x88" enables SIMATIC PCS 7 operator systems to exchange information with the following automation systems via the CS 275 plant bus: • AS 215 • AS 230, AS 230 K • AS 235, AS 235 K, AS 235 H • AS 388/TM, AS 488/TM • SIMATIC S5-150U/S5-155U The coupling package contains a bus-specific channel DLL and a TM Manager. The channel DLL adapts the TELEPERM M message frames to the OS-specific data structures and procedures by converting the protocol. The TM Manager is a configuration assistant that supports the following configuration functions: ORPA Import In accordance with the AS data defined in the PROGRAF AS+/NT configuration tool, the ORPA import function creates structured tags in the operator system for TELEPERM M standard and user blocks. The selection of parameters to be imported can be modified using filters and a dialog box. Block Import In the operator system, the block import function creates block instances of the block types defined in PROGRAF AS+/NT for TELEPERM M standard and user blocks. The selection of parameters to be imported can be modified using filters and a dialog box. Connection Import The connection import function generates connections in the TELEPERM M channel CS 275. It is possible to define here whether status and plain text messages are transmitted and a startup to the corresponding automation system is executed. Message Generator The Message Generator function determines the block instances which were imported into the operator system and generates messages for these in the AlarmLogging. The message texts can be parameterized. Message class and message type can be defined bit-specifically for MKS blocks. Batch Import The Batch Import function prepares the data for the internal data of SIMATIC BATCH. SIMATIC BATCH can then communicate with the interface blocks in TELEPERM M automation systems in the same manner as with SIMATIC PCS 7 automation systems. Coupling package upgrade/update to PCS 7/TM-OS V4.1 An upgrade package that also includes the PCS 7/TM-OCX program package is available to upgrade existing WinCC/TM V1.0x, PCS 7/TM-OS V2.x or V3.x coupling packages. One upgrade package is required for each SIMATIC PCS 7/TM-OS single station system, operator terminal or server. The Order No. of the upgrade must be selected according to the installed platform (PCS 7/TM-OS coupling package and/or PCS 7/TM-OCX (NORA) program package). PCS 7/TM-OS V4.0 coupling packages can be economically upgraded to V4.1 by means of an update.
2/6
Siemens ST PCS 7.2 · October 2009
Faceplate (here for the RN block) in the TELEPERM M NORA display (left) and the PCS 7 layout (right)
The PCS 7/TM-OCX (NORA) program package comprises: • Faceplates for the standardized display of operable TELEPERM M AS function blocks in various hierarchy levels (icon display/group display/loop display) • Faceplates for the visualization of PCS 7 driver blocks of the TELEPERM M I/Os The faceplates for the AS standard function blocks are comparable with the standardized displays of the TELEPERM M OS 525 operator system or with the SIMATIC PCS 7 faceplates. They are of multi-lingual design, i.e. the user can choose between the languages German, English and French. The related electronic documentation is supplied on CD in German and English. The process connection is made by linking the faceplate to the AS standard function block. The Object Control ActiveX (OCX) interactive graphics element performs the logic operation with the process tags. As a result, the PCS7/TM-OCX (NORA) program package not only makes the configuration of pictures easier, it also does much to simplify and speed up the entire OS configuration process. For some AS standard function blocks the PCS 7/TM-OCX (NORA) program package offers not only faceplates in the TELEPERM M NORA presentation but also faceplates in the PCS 7 layout. Both faceplate types can be used simultaneously on the same computer. However, you can use the displays of only one block type for the function "Select display using process tag".
© Siemens AG 2009
TELEPERM M migration Operator control and monitoring PCS 7/TM OS Intelligent alarm management The PCS 7/TM-OS coupling packages V4.1 support the intelligent alarm management function of the SIMATIC PCS 7 operator system V7.1. By means of intelligent alarm management, those messages which are of less significance for safe and fault-free plant operation during specific plant statuses can be visually and audibly hidden. These messages are still logged and archived as before. This saves a noticeable amount of work for the operators. Insignificant messages can be hidden in two ways: • Dynamically, i.e. depending on preconfigured definition for up to 32 operating states (Smart Alarm Hiding) • Manually, with time limit In the case of Smart Alarm Hiding, the status (commissioning, startup, service, etc.) of the unit is transferred to PCS 7/TM-OS by means the function block "SRAH" (Status Representation for Alarm Hiding) and its status message. Depending on this status of the process cell, messages which are irrelevant for the operator are hidden there. The function block for AS 23x and AS x88/TM with the fixed type name SRAH is a user block which can be downloaded to the corresponding automation system during operation. It is supplied on the software CD of PCS 7/TM-OS V4.1.
■ Integration Connecting systems with TELEPERM M basic functions to SIMATIC BATCH V7.1 Using the coupling packages for PCS 7/TM-OS it is possible to connect AS 23x or AS 488/TM automation systems, whose functional process areas are automated with GF blocks of the basic functions program package up to version V1.3 (6DS5305-8AA; released for delivery in 08/89), to SIMATIC BATCH V7.1. Connection takes place through the UNIB, TR1B and EM1B interface blocks, which are inserted in the AS structure. It can only be implemented with client/server-based multi-user systems. Single station systems (single stations) are not suitable for this. The interface blocks enable SIMATIC BATCH to dock on in order to forward control strategies, setpoints and phase change commands to the master recipe phase, and to read its status.
■ Ordering data
Order No.
OS single station corresponds to the SIMATIC PCS 7 Industrial Workstation, single station version, in Catalog ST PCS 7 SIMATIC PCS 7 ES/OS 547B BCE WXP SIMATIC PC in 19" rack, without monitor, keyboard or printer Core 2 Duo E6600 processor, 2.4 GHz, 2 GB RAM (2 x 1 GB), sound, SATA-RAID 1 with 2 x 250 GB hard disks, graphics controller on board with dynamic video memory, DVD±RW IDE burner, 3.5" floppy disk drive, optical mouse, 2 x 10/100/1000 Mbit/s Ethernet RJ45 (on board + network card with basic communication Ethernet) Windows XP Professional operating system MUI (German, English, French, Italian, Spanish, Chinese), SIMATIC PC DiagMonitor diagnostics software and SIMATIC PCS 7 ES/OS software V7.1 preinstalled; Restore DVDs Other items required: • Interface module for CS 275 incl. local bus connecting cable • SIMATIC PCS 7 OS software, single station V7.1 (for licensing) • PCS 7/TM-OS V4.1 coupling package • Optional: - Signal module - PCS 7/TM-OCX (NORA) V4.1
6ES7 650-0NF17-0YX0
C)
C) Subject to export regulations: AL: N, ECCN: 5D992
The dual-channel functionality of the operator system also supports connection to SIMATIC BATCH, i.e. plant units can be used by different systems within a recipe. It is irrelevant for the recipe whether a plant unit is on a SIMATIC PCS 7 automation system or on a TELEPERM M automation system. This is a great advantage particularly with plant expansions.
Siemens ST PCS 7.2 · October 2009
2/7
2
© Siemens AG 2009
TELEPERM M migration Operator control and monitoring PCS 7/TM OS
■ Ordering data
■ Ordering data
Order No.
OS server corresponds to the SIMATIC PCS 7 Industrial Workstation, server version, in Catalog ST PCS 7
2
SIMATIC PCS 7 OS server 547B BCE SRV03 SIMATIC PC in 19" rack, without monitor, keyboard or printer Core 2 Duo E6600 processor, 2.4 GHz, 2 x 1 GB RAM, sound, SATA-RAID 1 with 2 x 250 GB hard disks, graphics controller on board with dynamic video memory, DVD-ROM IDE, 3.5" floppy disk drive, optical mouse, 2 x 10/100/1000 Mbit/s Ethernet RJ45 (on board for connection to terminal bus + PCI card with basic communication Ethernet for double-channel operation) Windows Server 2003 operating system MUI (German, English, French, Italian, Spanish, Chinese), SIMATIC PC DiagMonitor diagnostics software and SIMATIC PCS 7 OS server software V7.1 pre-installed; Restore DVDs Other items required: • Interface module for CS 275 incl. local bus connecting cable • SIMATIC PCS 7 OS Software Server V7.1 (for licensing) • PCS 7/TM-OS V4.1 coupling package • Optional: - Signal module - For process visualization on the server: PCS 7/TM-OCX (NORA) V4.1
6ES7 650-0NH17-0YX0
C) Subject to export regulations: AL: N, ECCN: 5D992
2/8
Siemens ST PCS 7.2 · October 2009
Order No.
OS client corresponds to the SIMATIC PCS 7 Industrial Workstation, client version, in Catalog ST PCS 7 C)
PCS 7 OS Client 547B WXP SIMATIC PC in 19" rack, without monitor, keyboard or printer; Core 2 Duo E6600 processor, 2.4 GHz, 1 GB RAM (2 x 512 MB), SATA 250 GB hard disk, graphics controller on board with dynamic video memory, DVD-ROM IDE, 3.5" floppy disk drive, optical mouse, Ethernet 10/100/1000 Mbit/s (RJ45) on board for connection to terminal bus Windows XP Professional operating system MUI (German, English, French, Italian, Spanish, Chinese), SIMATIC PC DiagMonitor diagnostics software and SIMATIC PCS 7 ES/OS Client software V7.1 pre-installed; Restore DVDs • without multi-monitor graphics card
6ES7 650-0NG17-0YX0
C)
• with multi-monitor graphics card "2 Screens"
6ES7 650-0NG17-0YA0
C)
• with multi-monitor graphics card "4 Screens"
6ES7 650-0NG17-0YB0
C)
Other items required: • SIMATIC PCS 7 OS software Client V7.1 (for licensing) • Optional: - Signal module - PCS 7/TM-OCX (NORA) V4.1 Additional and expansion components PCS 7/TM-OS V4.1 coupling packages • PCS 7/TM-OS coupling package for AS 23x/AS x88 bilingual (German, English) Type of delivery: Certificate of license and authorization disk; software and electronic documentation on CD
6DS5 143-1AX
C)
PCS 7/TM-OCX (NORA) V4.1 program package Standardized displays for operable TELEPERM M AS function blocks and for PCS 7 driver blocks of the TELEPERM M I/Os, trilingual (German, English, French) Type of delivery: Certificate of license and authorization disk; electronic documentation (German, English) and software on CD Note: When the PCS 7/TM-OCX (NORA) is used, a 6DS5 037-1AX program package has to be ordered for each single station system (OS single station) and for each operator terminal (OS client) of a multi-user system. A program package is also required for the process visualization module if it is used on the server.
6DS5 037-1AX
C)
© Siemens AG 2009
TELEPERM M migration Operator control and monitoring PCS 7/TM OS
■ Ordering data Coupling package upgrade from PCS 7/TM-OS V4.0 to V4.1 consisting of software CD; without license for process coupling and PCS 7/TM-OCX
■ Ordering data
Order No. 6DS5 128-1XX00-2XX3
C)
Order No.
Subsequent expansion of S7 communications software for CP 1613 for communication with redundant AS
• Without license for process coupling and PCS 7/TM-OCX
6DS5 128-1XX00-2XX4
C)
• License for PCS 7/TM-OS AS 23x/AS x88 coupling package
6DS5 128-1XX70-2XX4
C)
SIMATIC NET PowerPack S7-REDCONNECT/2008 Software for expansion of S7-1613 to S7-REDCONNECT, runtime software, in 2 languages (German, English), running under Windows XP Professional / Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on memory stick
• License for PCS 7/TM-OCX
6DS5 128-1XX03-2XX4
C)
Components for OS connection to the CS 275 plant bus Refer to following section "CS 275 communication"
• License for PCS 7/TM-OS AS 23x/AS x88 coupling package and PCS 7/TM-OCX
6DS5 128-1XX73-2XX4
C)
Coupling package upgrade from PCS 7/TM-OS V1.x/V2.x/V3.x to V4.1 Comprising software CD and:
Interfacing to Industrial Ethernet plant bus, upgrading from BCE communication to CP 1613 communication CP 1613 A2 PCI card for connection to Industrial Ethernet, with ITP and RJ45 connections
6GK1 161-3AA01
Communications software for CP 1613
6GK1 716-0HB71-3AC0
C)
2
C) Subject to export regulations: AL: N, ECCN: 5D992
Note: Further versions of the SIMATIC PCS 7 Industrial Workstation as well as supplementary/expansion components such as network cable, signal module, multi-monitor graphics cards, OS redundancy components, smart card readers, keyboards or process monitors can be found in the SIMATIC PCS 7 Catalog ST PCS 7. In this catalog you can also select the SIMATIC PCS 7 OS software for the different versions of the PCS 7/TM operator station (OS single station, OS server or OS client).
■ More information
• SIMATIC NET S7-1613/2008 for Industrial Ethernet (for S7 communication, except with redundant AS) S7 communications software for CP 1613 A2/CP 1623, runtime software, in 2 languages (German, English), running under Windows XP Professional / Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on memory stick
6GK1 716-1CB71-3AA0
• SIMATIC NET S7-REDCONNECT/2008 (for S7 communication with redundant AS) Software for fail-safe S7 communication over redundant networks, for CP 1613 A2/CP 1623, runtime software, in 2 languages (German, English), running under Windows XP Professional / Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on memory stick
6GK1 716-0HB71-3AA0
C)
Customized special configurations for PCS 7/TM-OS operator systems We would be pleased to support you if you require a customized configuration for the PCS 7/TM-OS systems. Please contact your regional Siemens representative.
C)
Siemens ST PCS 7.2 · October 2009
2/9
© Siemens AG 2009
TELEPERM M migration Engineering PROGRAF AS Interfacing to the SIMATIC PCS 7 plant bus
■ Overview OS clients
PCS 7/TELEPERM engineering station AS/OS Hardware: SIMATIC PCS 7 Industrial Workstation (Single Station/Server), N-PCI incl. local bus connecting cable
2 Terminal bus
Also: - PROGRAF AS+/NT - Coupling package PCS 7/TM-OS - PCS 7 engineering software AS/OS
PCS 7/TM OS Server
Plant bus CS 275
In the case of the SIMATIC PCS 7 Industrial Workstations V7.1 single station/server versions offered below, the interfacing to the SIMATIC PCS 7 plant bus Industrial Ethernet is implemented via RJ45 network card 10/100/1000 Mbit/s and Basic Communication Ethernet (BCE). An alternative to the BCE communication is the more powerful communication by means of CP 1613 A2/CP 1623 and the S7-1613/S7-REDCONNECT communications software. This is however only necessary for communication with more than 8 automation systems and when using redundant automation systems. SIMATIC PCS 7 Industrial Workstations with BCE communication can also be subsequently upgraded to CP 1613/1623 communication. To this end, in addition to the CP 1613 A2/CP 1623 module, they require either the S7-1613 communication software or S7-REDCONNECT. In contrast to the S7-1613, the S7-REDCONNECT communication software also supports communication with redundant automation systems. PROGRAF AS
AS 23x
AS x88
Based on the SIMATIC PCS 7 Industrial Workstation, single station or server version, a universal PCS 7/TELEPERM Engineering Station AS/OS can be implemented by the addition of hardware and software components, which can then be used for the engineering of all subsystems networked by means of TELEPERM M plant bus CS 275 and SIMATIC PCS 7 Industrial Ethernet plant bus.
■ Design PCS 7/TELEPERM Engineering Station AS/OS V7.1 The SIMATIC PCS 7 Industrial Workstations V7.1, single station/server versions are suitable as basic hardware for a PCS 7/TELEPERM Engineering Station AS/OS V7.1. These are already equipped with interface modules for connection to the plant bus and the terminal bus of SIMATIC PCS 7. Detailed information on the technology, scope of delivery and ordering data of all versions of the SIMATIC PCS 7 Industrial Workstation V7.1 as well as options/expansions can be found in the "SIMATIC PCS 7 Industrial Workstation" section of the current SIMATIC PCS 7 Catalog ST PCS 7. The expansion to a PCS 7/TELEPERM Engineering Station AS/OS V7.1 requires additional components: • CS 275 interface module N-PCI and local bus connecting cable (see section on "Communication") • Program package PROGRAF AS+/NT V4.03, Order No. 6DL5 255-1CX • PCS 7/TM-OS V4.1 coupling package for AS 23x/AS x88 (for details, see section on "Operation and Monitoring") • SIMATIC PCS 7 Engineering Software AS/OS V7.1 with AS/OS Engineering unlimited POs and AS runtime license for 600 POs Note: The SIMATIC PCS 7 Engineering Software AS/OS V7.1 is released for a 2-hour OS test mode. Continuous use in OS productive operation is not possible.
The program package PCS 7/TM-OCX (NORA) V4.1 can also be used as an option (for details, see section on "Operation and Monitoring"). For the SIMATIC PCS 7 Engineering Software AS/OS V7.1 the number of configurable process objects or tags can be increased if required by adding SIMATIC PCS 7 Engineering PowerPacks (see SIMATIC PCS 7 Catalog ST PCS 7, Chapter "Engineering System", Section "ES Software").
2/10
Siemens ST PCS 7.2 · October 2009
The PROGRAF AS+/NT program package is a variant of the PROGRAF AS engineering software that can execute on the following operating systems: • Windows NT 4.0 • Windows 2000 Professional • Windows XP Professional • Windows 2000 Server • Windows Server 2003 As a component of a PCS 7/TELEPERM Engineering Station AS/OS V7.1, single station or server version, PROGRAF AS+/NT V4.03 can be used for: • Engineering, testing and commissioning of the automation systems - AS 230, AS 230 K - AS 235, AS 235 K, AS 235 H - AS 388/TM and AS 488/TM (incl. the der technical design versions AS 488 S and AS 488 K) • Software maintenance and documentation A powerful function block diagram (FBD) editor with autorouter that can also represent dynamic values and curves, libraries for reusable elements, rational import and export functions, as well as practical commissioning and test functions offer you effective support for the graphical structuring, testing, optimizing and documentation of the user software of your TELEPERM M automation systems. Structures of existing installed automation systems can be read into PROGRAF AS+/NT, re-compiled and then graphically processed or documented. Note: PROGRAF AS+/NT V4.03 is still available for TELEPERM M migration projects, quoting Order No. 6DL5 255-1CX.
© Siemens AG 2009
TELEPERM M migration Engineering PROGRAF AS
■ Integration
■ Ordering data
Converting existing user software The user software represents a large portion of the total investment and know-how. Hence the quality of its conversion into the new system world is a key criterion for a migration’s economic efficiency. We provide you with fast and reliable conversion of your user software for use on the new SIMATIC PCS 7 system platform. In doing so we make allowance for sector-specific properties as well as special plant solutions. As a result of the modern tools that we developed ourselves, you profit from software of constant quality, reliability and verifiability. All the conversion steps performed are documented, as are the manual reconfigurations occasionally required. For quotations and additional information, please contact your regional Siemens representative.
■ Ordering data
Order No.
PCS 7/TELEPERM Engineering Station AS/OS SIMATIC PCS 7 Industrial Workstation V7.1, single station or server version SIMATIC PCS 7 ES/OS 547B BCE WXP SIMATIC PC in 19" rack, without signal module, monitor, keyboard or printer Core 2 Duo E6600 processor, 2.4 GHz, 2 x 1 GB RAM, sound, SATA-RAID 1 with 2 x 250 GB hard disks, graphics controller on board with dynamic video memory, DVD±RW DVD burner, 3.5" floppy disk drive, optical mouse, 2 x 10/100/1000 Mbit/s Ethernet RJ45 (on board + network card with basic communication Ethernet) Windows XP Professional operating system MUI (German, English, French, Italian, Spanish, Chinese), SIMATIC PC DiagMonitor diagnostics software and SIMATIC PCS 7 ES/OS software V7.1 preinstalled; Restore DVDs
6ES7 650-0NF17-0YX0
SIMATIC PCS 7 OS server 547B BCE SRV03 SIMATIC PC in 19" rack, without signal module, monitor, keyboard or printer Core 2 Duo E6600 processor, 2.4 GHz, 2 x 1 GB RAM, sound, SATA-RAID 1 with 2 x 250 GB hard disks, graphics controller on board with dynamic video memory, DVD-ROM IDE, 3.5" floppy disk drive, optical mouse, 2 x 10/100/1000 Mbit/s Ethernet RJ45 (on board + PCI card with basic communication Ethernet) Windows Server 2003 operating system MUI (German, English, French, Italian, Spanish, Chinese), SIMATIC PC DiagMonitor diagnostics software and SIMATIC PCS 7 OS server software V7.1 pre-installed; Restore DVDs
6ES7 650-0NH17-0YX0
C)
C)
Order No.
Other items required: • Interface module for CS 275 incl. local bus connecting cable • PROGRAF AS+/NT V4.03 program package for configuration of TELEPERM M AS 23x/AS x88 • PCS 7/TM-OS V4.1 coupling package for AS 23x/AS x88 • SIMATIC PCS 7 Engineering Software AS/OS V7.1 for unlimited POs, incl. AS Runtime license for 600 POs • Optional: PCS 7/TM-OCX (NORA) V4.1
2
Additional and expansion components SIMATIC PCS 7 Engineering Software AS/OS V7.1 AS/OS Engineering unlimited POs and AS Runtime license for 600 POs Software enabled for two-hour OS test mode, not to be used for OS productive operation 5 languages (German, English, French, Italian, Spanish), executes with Windows XP Professional or Windows Server 2003, floating license for 1 user Type of delivery: License key memory stick, certificate of license including terms and conditions Note: For additional SIMATIC PCS 7 Engineering PowerPacks see Catalog ST PCS 7, Chapter "Engineering System", Section "ES Software".
6ES7 658-5AF17-0YA5
PCS 7/TM-OS V4.1 coupling package for AS 23x/AS x88 2 languages (German, English) Type of delivery: Certificate of License and authorization disk; software and electronic documentation on CD
6DS5 143-1AX
PCS 7/TM-OCX (NORA) V4.1 program package Standardized displays for operable TELEPERM M AS function blocks and for PCS 7 driver blocks of the TELEPERM M I/Os, trilingual (German, English, French) Type of delivery: Certificate of license and authorization disk; electronic documentation (German, English) and software on CD
6DS5 037-1AX
C)
C) Subject to export regulations: AL: N, ECCN: 5D992
Siemens ST PCS 7.2 · October 2009
2/11
© Siemens AG 2009
TELEPERM M migration Engineering PROGRAF AS
■ Ordering data
2
■ Ordering data
Order No.
PROGRAF AS+/NT V4.03 Configuration software for TELEPERM M AS 23x/AS x88 automation systems, can be used with Windows NT 4.0/ 2000/ 2000 Server/ XP/ Server 2003 Type of delivery: • CD with program package in German and English • Software protection (dongle)
Still available for TELEPERM M migration, Order No. 6DL5 255-1CX.
Update PROGRAF AS+/NT V4.0x to current version
Still available for TELEPERM M migration, Order No. 6DL5 255-1CX00-4XX3.
Upgrade PROGRAF AS+ Version 2 or 3 (with Windows 3.11) to current version with return of dongle
Still available for TELEPERM M migration, Order No. 6DL5 255-1CX00-4XX4.
SIMATIC NET PowerPack S7REDCONNECT/2008 Software for expansion of S7-1613 to S7-REDCONNECT, runtime software, in 2 languages (German, English), running under Windows XP Professional / Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on memory stick
C)
A) Subject to export regulations: AL: N, ECCN: EAR99H
CP 1613 A2 PCI card for connection to Industrial Ethernet, with ITP and RJ45 connections
6GK1 161-3AA01
CP 1623 PCI Express x1 card for connection to Industrial Ethernet (10/100/1000 Mbit/s), with 2-port switch (RJ45)
6GK1 162-3AA00
A)
• SIMATIC NET S7-1613/2008 for Industrial Ethernet (for S7 communication, except with redundant AS) S7 communications software for CP 1613 A2/CP 1623 runtime software, in 2 languages (German, English), running under Windows XP Professional / Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on memory stick
6GK1 716-1CB71-3AA0
C)
• SIMATIC NET S7-REDCONNECT/2008 (for S7 communication with redundant AS) Software for fail-safe S7 communication over redundant networks, for CP 1613 A2/CP 1623 runtime software, in 2 languages (German, English), running under Windows XP Professional / Server 2003, single license for 1 installation, software and electronic manual on CD-ROM, license key on memory stick
6GK1 716-0HB71-3AA0
C)
Communications software for CP 1613 A2
Siemens ST PCS 7.2 · October 2009
6GK1 716-0HB71-3AC0
Components for connection of the AS/OS engineering station to the CS 275 plant bus Refer to following section "CS 275 communication"
Interfacing to Industrial Ethernet plant bus, upgrading from BCE communication to CP 1613 communication
2/12
Order No.
Subsequent expansion of S7 communications software for CP 1613 for communication with redundant AS
C) Subject to export regulations: AL: N, ECCN: 5D992
Note: Further versions of the SIMATIC PCS 7 Industrial Workstation, supplementary/expansion components such as network cables, keyboards, multi-monitor graphics cards or process monitors, as well as additional SIMATIC PCS 7 engineering software, can be found in Catalog ST PCS 7.
© Siemens AG 2009
TELEPERM M migration Communication CS 275
■ Overview Through connection to the TELEPERM M CS 275 plant bus, PCS 7/TM-OS operator systems and engineering stations with PROGRAF AS+/NT have access to all types of the following automation systems of an existing TELEPERM M plant: • AS 230, AS 235, AS 488/TM • S5-150U, S5-155U Characteristic features of the CS 275 bus architecture: • Participants within a local range or a cabinet group are connected together at distances up to 20 m by means of the 20-m local bus. • The transition from the 20-m local bus to the remote bus is made using inductive bus converters UI. • Up to 9 participants (each UI counts as 1 participant) can be connected into a local bus island using the 20-m local bus. • The remote bus combines distributed systems/local bus islands over distances up to 4 km. • The local bus is redundant as standard, a redundant design for the remote bus is optional. There are various possibilities for connecting the engineering/operator stations to the CS 275 plant bus (see design) depending on the respective initial situation and on the type and scope of migration project.
■ Design The following picture and the associated product overview show the basic possibilities for the CS 275 connection of the engineering/operator stations as well as the connection components required in each case. The N-PCI interface module that acts as a CS 275 interface is not yet integrated into the SIMATIC PCS 7 Industrial Workstations, single station or server versions, that can be used as the basic hardware for an engineering/operator station. It must therefore be ordered separately and retrofitted there. The current N-PCI interface module can be used with • PCS 7/TM-OS V3.1 SP1 and later and • PROGRAF AS+/NT V4.03 and later. It operates with 3.3 V and 5 V PCI bus signal voltage. The N-PCI driver V1.4 or higher that it requires, is part of the scope of delivery of PCS 7/TM-OS in V3.1 SP1 or higher.
N-PCI
N-PCI
ES 902 e.g. to UI, N-AS
AV UI1/ UI2
1
2
Max. 15 m
Max. 5 m Remote bus connection unit
N-PCI 3
AV
2.5 m
UI1/ UI2
N-PCI
OS 26x
3
AV 2.5 m
Remote bus connection unit
AS cabinet TELEPERM M
N-PCI
N-PCI N-PCI connecting cable 4
1
4
Max. 5 m Basic possibilities for ES/OS connection to the CS 275 plant bus
Siemens ST PCS 7.2 · October 2009
2/13
2
© Siemens AG 2009
TELEPERM M migration Communication CS 275 Overview of connecting cables for ES/OS connection to the CS 275 plant bus Connector type (see graphic)
Number of Field of application connectors 4
1
2
Preassembly, length
Order No.
To connect the N-PCI interface module to a Sub-D socket 0.3 m ES 902 0.3 m ES 902 6DS8 210-8MB remote bus connection unit (UI1, UI2 and 0.3 m ES 902 AV) Sub-D socket 3 m ES 902 0.3 m ES 902 6DS8 210-8MC 0.3 m ES 902 Sub-D socket 5 m ES 902 0.3 m ES 902 0.3 m ES 902
1
2
6DS8 210-8SC
To connect the N-PCI to a local bus island; Sub-D socket 0.5 m cable end free connection to an existing ES 902 connecSub-D socket 5 m cable end free tor, e.g. to UI or N-AS Sub-D socket 10 m cable end free
6DS8 211-8SB
Sub-D socket 15 m cable end free
6DS8 211-8ED
6DS8 211-8SC 6DS8 211-8AD
3
2
To connect the N-PCI to a local bus island; Sub-D socket 2.5 m ES 902 connection on distributor (AV) in remote bus connection unit or TELEPERM M AS cabinet
6DS8 208-8KC
4
3
To extend a connecting cable 1, 2, 3 or 4 in Sub-D socket 0.3 m Sub-D socket 0.3 m order to connect more than two ES/OS sys- Sub-D plug tems to local bus island Sub-D socket 1,5 m Sub-D socket 0.3 m Sub-D plug
6DS8 212-8MB
■ Ordering data N-PCI interface module for the ES/OS connection to the CS 275 local bus, suitable for 3.3 V and 5 V PCI bus signal voltage
Order No. 6DP1 724-8BA
Preassembled connecting cables for ES/OS connection to the CS 275 plant bus Connecting cable between N-PCI and remote bus connection unit with 4 connectors (1 Sub-D socket, 3 ES 902); for distances between N-PCI and UI1 up to: • 0.3 m
6DS8 210-8MB
•3m
6DS8 210-8MC
•5m
6DS8 210-8SC
Connecting cable between N-PCI and local bus island (ES 902 connector) with 1 connector (Sub-D socket) and one open cable end for connection to ES 902 connector; length: • 0.5 m
6DS8 211-8SB
•5m
6DS8 211-8SC
• 10 m
6DS8 211-8AD
• 15 m
6DS8 211-8ED
2/14
Siemens ST PCS 7.2 · October 2009
6DS8 212-8EC
Sub-D socket 3 m Sub-D socket 0.3 m Sub-D plug
6DS8 212-8MC
Sub-D socket 5 m Sub-D socket 0.3 m Sub-D plug
6DS8 212-8SC
■ Ordering data
Order No.
Connecting cable between N-PCI and local bus island (distributor) with 2 connectors (1 Sub-D socket, 1 ES 902 for connection to AV); length: • 2.5 m
6DS8 208-8KC
Connecting cable for connection of more than 2 systems with N-PCI to a local bus island (extended by any cable for the N-PCI connection via its Sub-D socket) with 3 connectors (2 Sub-D sockets, 1 Sub-D plug for connection to other cables); length between the two Sub-D sockets: • 0.3 m
6DS8 212-8MB
• 1.5 m
6DS8 212-8EC
•3m
6DS8 212-8MC
•5m
6DS8 212-8SC
Accessories ES 902 connector for combination with CS 275 local bus connecting cables with open cable end, e.g. 6DS8 211-8..
6DS9 200-8AA
© Siemens AG 2009
TELEPERM M migration Communication GT104CS gateway
■ Overview
■ Function The Gateway GT104CS is capable of processing the cyclic data exchange between the TELEPERM M automation systems on the plant bus CS 275 and up to 32 SIMATIC PCS 7 automation systems on the Industrial Ethernet plant bus. The CPU of a SIMATIC PCS 7 automation system can process transmitted or received data of at least 10 AKS- + 10 AKE- + 10 BKS- + 10 BKE-blocks in a 1s cycle. This corresponds to 280 analog values and 1280 binary values per second in each communication direction.
■ Configuration At the GT104CS gateway, the bus and bus node address are to be set on the plant bus CS 275 by means of DIP switches. For communication with the SIMATIC PCS 7 automation system, the gateway requires only a few parameters (IP address). The connection between the SIMATIC PCS 7 automation systems and the gateway is configured using the SIMATIC Manager. SIMATIC PCS 7 process cells on the Industrial Ethernet plant bus can be linked perfectly with existing TELEPERM M process cells on the CS 275 plant bus by a combination of the PCS7/TM-OS operator system with dual-channel functionality and GT104CS gateway.
■ Application The cross-bus communication load can be evenly distributed: • The PCS 7/TM-OS with dual-channel functionality handles - AS-OS communication with the automation systems on the CS 275 and Industrial Ethernet plant buses, as well as - time-of-day synchronization for the TELEPERM M unit • The cross-bus AS-AS communication operates via the GT104CS gateway. The gateway behaves like a virtual automation system. In connection with the GT104CS gateway, the automation systems AS 488/TM, AS 235 and AS 230 can be used on the TELEPERM M side. The gateway has a bus and node address on the TELEPERM M CS 275 plant bus, via which the cyclic data can be exchanged with as many as 32 automation systems on the SIMATIC PCS 7 Industrial Ethernet plant bus (TCP/IP protocol). The communication is configured in the participating function blocks of the TELEPERM M and SIMATIC PCS 7 automation systems and can also be performed online. Once the connection is set up, the gateway couples the configured transmission and reception blocks.
The necessary configuration work for this is minimal. For the SIMATIC PCS 7 automation systems, function blocks for the TELEPERM M standard functions AKS, BKS, AKE and BKE are also supplied, as well as a central communications block TM_LINK. By means of the TM_LINK communications block and the GT104CS gateway, the AKS, BKS, AKE and BKE blocks of the SIMATIC PCS 7 automation systems communicate with the AKS, BKS, AKE and BKE blocks in the TELEPERM M automation systems, which are assigned by addressing. The function block TM_LINK uses the S7 system functions USEND and URECV internally for communication with the gateway.
■ Ordering data
Order No.
GT104CS gateway: for the AS-AS bus communication between TELEPERM M and SIMATIC PCS 7 Hardware incl. memory card with gateway system software, AKS/BKS/AKE/BKE function blocks
9AE4 100-1EA00
D)
D) Subject to export regulations: AL: N, ECCN: 4A994X
■ More information The GT104CS gateway is a SIMATIC PCS 7 add-on product. The responsibility for this product is as specified below. If you have any questions concerning this product, please contact your regional Siemens representative or the department responsible for the product: Siemens AG Industry Sector Industry Solutions Karlsruhe Phone: +49 721 595-6708 Fax: +49 721 595-6383 E-mail:
[email protected]
■
Siemens ST PCS 7.2 · October 2009
2/15
2
© Siemens AG 2009
TELEPERM M migration
2
2/16
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
APACS+/QUADLOG migration
3
3/2
Introduction
3/4 3/4
Automation APACS+ controller migration using DP/IO bus link and AS 417H QUADLOG controller migration using DP/IO bus link and AS 417F
3/7 3/11 3/11
Operator control and monitoring PCS 7/APACS+ Operator System
3/14 3/14
Engineering PCS 7/APACS+ OS Engineering Station
3/17 3/17
Communication Industrial Ethernet Module (IEM)
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
APACS+/QUADLOG migration Introduction
■ Overview Engineering system
PCS 7 OS / BATCH clients
(dualchannel)
PCS 7/APACS+ OS Server
PCS 7 BATCH server
PCS 7 OS server
PCS 7 central archive server
3 Industrial Ethernet (single/redundant)
MBUS
IEM
AS 414/ AS 416/ AS 417
ET 200M
DP/IO Bus Link
MBUS
AS 414FH/ AS 417FH
AS 417H (Single/ Redundancy Station)
IEM
ET 200M DP/PA Link ET 200M
ET 200M
APACS+/ QUADLOG
APACS+/ QUADLOG
APACS+ I/Os
Field devices PROFIBUS
Configuration example of APACS+/QUADLOG migration
The APACS+ process control system has been used successfully world-wide for over 15 years. Its functionality, reliability and user-friendliness have been demonstrated in more than 10 000 installed systems. Migration of the process control system based on APACS+/QUADLOG controllers with the innovative SIMATIC PCS 7 OS operation and monitoring systems from Siemens provides the opportunity for retaining proven functions and for significantly increasing the functionality and performance at the same time through specific modernization. With its open system platform, SIMATIC PCS 7 provides an ideal basis for modern, future-oriented and economical automation solutions in all sectors.
3/2
Siemens ST PCS 7.2 · October 2009
Depending on the plant size, the hardware and user software of an installed APACS+ system represent a considerable investment volume and, together with the know-how of the operating and maintenance personnel, an enormous value. To preserve and expand the installed basis and to increase its value, Siemens developed a migration strategy which aims to modernize existing operator and engineering systems with SIMATIC PCS 7 while retaining the APACS+/QUADLOG controllers and the lower-lying I/O level. With this strategy, customers can migrate their existing systems efficiently and economically without having to replace any controllers, I/O devices or their wiring, and without any loss of associated investment in the system configuration. In addition, excellent alternatives are provided at the controller level by the AS 41x of SIMATIC PCS 7, especially with plant expansions. These are supported by the controller-controller communication via Industrial Ethernet Modules (IEM) and by PCS 7/APACS+ operator systems which can communicate with both APACS+/QUADLOG controllers and AS 41x by dual channel.
© Siemens AG 2009
APACS+/QUADLOG migration Introduction
■ Benefits Through the migration to SIMATIC PCS 7, the customers of APACS+ also profit from the numerous advantages provided by Totally Integrated Automation (TIA) and the facilities already provided by the system for integration into the corporate information network. These include integration of the SIMATIC IT Manufacturing Execution System as well as monitoring via the World Wide Web or OPC data exchange with IT other applications.
■ More information You can find detailed information, ordering data and technical specifications on individual migration products in the following sections "PCS 7/APACS+ Engineering Station" and "PCS 7/APACS+ Operator System". Additional information is available in the Internet under: www.siemens.com/simatic-pcs7/migration
In addition to the above-mentioned technical aspects, future compatibility is also an important argument in favor of APACS+/QUADLOG migration. This is achieved by investment by Siemens in continuous product development and the longterm, global servicing for its range of SIMATIC products.
3
■ Options Converting OS user software The modern Siemens DBA technology permits fast and secure implementation of your user software. Your investment in the configuration of the existing system is therefore safeguarded. It goes without saying that we also offer this conversion as a service. But you can call upon the services of our experienced migration specialists not only for this reason, but also when generating new graphics. We would be pleased to provide you with an individual quotation. For quotations and additional information, please contact your regional Siemens representative.
Siemens ST PCS 7.2 · October 2009
3/3
© Siemens AG 2009
APACS+/QUADLOG migration Automation APACS+ controller migration using DP/IO bus link and AS 417H
■ Overview The PCS 7 APACS+ DP/IO bus link offers the possibility of replacing existing APACS+ controllers (ACM, ACM+ or ACMx) with more powerful SIMATIC PCS 7 AS 417H stations (single station AS 417-4-1H or redundancy station AS 417-4-2H), without having to renew the installed APACS+ I/O modules, field wiring and field technology. The ACM transition board and APACS+ CPU in the module rack are simply replaced by the externally identical components DP/IO bus link transition board and PCS 7 APACS+ DP/IO bus link. The PCS 7 APACS+ DP/IO bus link can then be connected to the AS 417H via the PROFIBUS DP interface of the DP/IO bus link transition boards.
3
As a result of the higher performance and speed of the SIMATIC PCS 7 AS 417H, it is not only possible to replace the controllers on a 1:1 basis, but also to reduce the number of them. One SIMATIC PCS 7 AS 417H automation system is capable of replacing as many as three 3 APACS+ controllers. The PCS 7 APACS+ DP/IO bus link supports both non-redundant and redundant configurations (peer-to-peer redundancy). A AS 417H (single station/redundancy station) with APACS+ I/O modules on the PCS 7 APACS+ DP/IO bus link can also be expanded via PROFIBUS DP with ET 200M remote I/Os.
■ Design Non-redundant configuration with AS 417H single station SIMATIC PCS 7 AS 417H Single Station
Connection of up to 3 DP/IO bus links each with up to 28 APACS+ I/O modules DP/IO bus link
CP 443-5
Maximum configuration using the example of a non-redundant architecture with AS 417H single station (AS 417-4-1H)
A PCS 7 APACS+ DP/IO bus link inserted in place of the APACS+ CPU in the former controller module rack is connected via its transition board to a PROFIBUS DP Master interface of the AS 417H single station. For each AS 417H single station as many as 3 PCS 7 APACS+ DP/IO bus links - each with up to 28 APACS+ I/O modules - can be connected via two internal PROFIBUS DP Master interfaces and one CP 443-5 module. In total this means a maximum of 84 APACS+ I/O modules can be connected. The actual limit value depends on the type and the channel allocation of the I/O modules used. Typical numbers are about 15 to 25 APACS+ I/O modules per PCS 7 APACS+ DP/IO bus link.
3/4
Siemens ST PCS 7.2 · October 2009
The actual maximum configuration can be determined using the memory calculator. In doing so, the memory requirement of the module types used is to be multiplied by the respective number of modules. In addition, the memory requirement of the channel types used is to be multiplied by the respective number of channels. The value obtained by adding the two subtotals for modules and channels must not exceed 65 535 bytes.
© Siemens AG 2009
APACS+/QUADLOG migration Automation APACS+ controller migration using DP/IO bus link and AS 417H Module type
Memory calculator
Channel type
Number of channels
Channel size
Memory requirement per channel type [bytes]
Enter the number of each module and channel type in the correspond- EAM ing cell and calculate the total memory requirement. EAM
ACDI
x
62
=0
AVDI
x
62
=0
EAM
CPIF
x
90
=0
EAM
CPIT
x
54
=0
EAM
EACI
x
78
=0
EAM
EADO
x
62
=0
EAM
EAOC
x
90
=0
Module type
Number of modules
Module mem- Memory requirement ory requireper module type ment [bytes]
EAM
x
630
=
0
EAM
EAVI
x
78
=0
IDM 115V
x
630
=
0
EAM
VPIF
x
90
=0
IDM 230V
x
630
=
0
EAM
VPIT
x
54
=0
IDM DC
x
738
=
0
IDM
IDDO
x
126
=0
ODM 115V
x
630
=
0
IDM
IDMI
x
50
=0
RTM
x
638
=
0
ODM
SDOC
x
66
=0
SAI
x
630
=
0
RTM
RIC
x
102
=0
SAM
x
630
=
0
RTM
RTD
x
114
=0
SDM 24V
x
94
=
0
SAI
SAAI
x
102
=0
SDM+ 24V
x
738
=
0
SAM
ACDO
x
66
=0
SDM+ 48V
x
738
=
0
SAM
SADI
x
62
=0
VIM
x
642
=
0
SAM
SAIC
x
86
=0
x
400
=
400
SAM
SAOC
x
102
=0
400
SDM
DPCO
x
62
=0
SDM
SDIC
x
42
=0
SDM
SDOC
x
66
=0
SDM
SOEI
x
90
=0
SDM
SOEO
x
110
=0
VIM
TIC_
x
102
=0
VIC
x
98
=0
DPIOB
1
Total memory requirement for modules Total memory requirement for modules and channels
400
Available memory space
65 535
VIM
Remaining memory space
65 135
Total memory requirement, channels
Peer-to-peer redundancy with AS 417H redundancy station
SIMATIC PCS 7 AS 417H Redundancy Station
3
=0
In the case of peer-to-peer redundancy, each redundant PCS 7 APACS+ DP/IO bus links is connected in a former APACS+ controller module rack via its transition boards to one of two redundant PROFIBUS DP Master interfaces of an AS 417H Redundancy Station (AS 417-4-2H). . For synchronization, the two redundant PCS 7 APACS+ DP/IO bus links are to be connected additionally with a DP/IO bus redundancy cable via their transition boards. The configuration shown in the example of a non-redundant architecture can in principle be applied to the peer-to-peer redundancy with the AS 417H redundancy station.
DP/IO Bus Link APACS I/Os
Redundancy cable
Transition Board
IOBUS
Example configuration for peer-to-peer redundancy with AS 417H redundancy station (AS 417-4-2H)
Siemens ST PCS 7.2 · October 2009
3/5
© Siemens AG 2009
APACS+/QUADLOG migration Automation APACS+ controller migration using DP/IO bus link and AS 417H
■ Integration
■ Ordering data
A CD with the following content is shipped together with the PCS 7 APACS+ DP/IO bus link: • Hardware configuration file for parameterizing all APACS+ I/O modules (for integration in the SIMATIC Manager of SIMATIC PCS 7) • Function block library with the channel drivers of the APACS+ I/O modules as well as diagnostics blocks and faceplates • Documentation
3
The software on this CD supports the integration of the PCS 7 APACS+ DP/IO bus links and of the APACS+ I/O modules in SIMATIC PCS 7. Together with the SIMATIC PCS 7 system software it enables: • Graphical hardware parameterization of the APACS+ I/O modules with online diagnostics • Generation of hardware and software alarm messages for the APACS+ I/O modules and the PCS 7 APACS+ DP/IO bus link • Operation and monitoring, as well as monitoring of the PCS 7 APACS+ DP/IO bus links and of the APACS+ I/O modules
Order No. 6EQ2 014-0CE00-0XA0
A)
DP/IO bus link transition board for the PROFIBUS DP interfacing of the PCS 7 APACS+ DP/IO bus links to the AS 417H Note: One transition board is required for each PCS 7 APACS+ DP/IO bus link.
6EQ2 013-1CE00-0XA0
A)
DP/IO bus redundancy cable, length 1 m for the connection of two redundant PCS 7 APACS+ DP/IO bus links for synchronization
6EQ2 013-0CE10-0XA0
A)
PCS 7 APACS+ DP/IO bus link Type of delivery: • Electronic module • CD with function block library, configuration software and electronic documentation Additional components
AS 417H automation systems (bundles) Individual configuration of the AS 417H bundles with the following basic data; completion of order numbers by selecting the preconfigured ordering units from Catalog ST PCS 7, Section "FaultTolerant Automation Systems" or by means of special configurators in the Industry Mall: SIMATIC PCS 7 AS single station / SIMATIC PCS 7 AS redundancy station) Single station AS 417-4-1H Preassembled and tested, memory card 16 MB RAM (up to about 3 000 POs), 1 x CPU 417-4H (up to about 2 500 POs)
6ES7 654-8EM..-..B.
Redundancy Station AS 417-4-2H Preassembled and tested, memory card 16 MB RAM (up to about 3 000 POs), 2 x CPU 417-4H (up to about 2 500 POs)
6ES7 656-8EM..-..B.
A) Subject to export regulations: AL: N, ECCN: EAR99H
Note: For additional SIMATIC PCS 7 ordering data, particularly for operator system and engineering system, see Catalog ST PCS 7.
3/6
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
APACS+/QUADLOG migration Automation QUADLOG controller migration using DP/IO bus link and AS 417F
■ Overview The PCS 7 QUADLOG DP/IO bus link offers the possibility of replacing existing QUADLOG controllers (CCM, CCM+ or CCMx) with a more powerful SIMATIC PCS 7 AS 417F (single station) or SIMATIC PCS 7 AS 417FH (redundancy station), without having to renew the installed QUADLOG I/O modules, field wiring and field technology. The ACM transition board and QUADLOG CPU in the module rack are simply replaced by the externally identical components DP/IO bus link transition board and PCS 7 QUADLOG DP/IO bus link. The PCS 7 QUADLOG DP/IO bus link can then be connected to the AS 417F/FH via the PROFIBUS DP interface of the DP/IO bus link transition boards. As a result of the higher performance and speed of the SIMATIC PCS 7 AS 417F/FH, it is not only possible to replace the controllers on a 1:1 basis, but also to reduce the number of them. One SIMATIC PCS 7 AS 417F/FH automation system is capable of replacing as many as three 3 QUADLOG controllers. The PCS 7 QUADLOG DP/IO bus link supports both nonredundant and redundant configurations (node-to-node redundancy). An AS 417F/FH (single station/redundancy station) with QUADLOG I/O modules on the PCS 7 QUADLOG DP/IO bus link can also be expanded via PROFIBUS DP with ET 200M remote I/Os.
■ Design Non-redundant configuration with AS 417F (single station) SIMATIC PCS 7 AS 417F (single station)
OVP
DP/IO bus link
OVP
Connection of one or two DP/IO bus links each with up to 28 partly configured up to 14 fully configured QUADLOG I/O modules
OVP: over voltage protection
Maximum configuration using the example of a non-redundant architecture with AS 417F (single station)
A PCS 7 QUADLOG DP/IO bus link inserted in place of the QUADLOG CPU in the former controller module rack is connected via its transition board to a PROFIBUS DP Master interface of the AS 417F (single station). For each AS 417F this means that one or two PCS 7 QUADLOG DP/IO bus links each with up to 14 fully configured or 28 partly configured QUADLOG-I/O modules can be connected via two PROFIBUS DP Master interfaces. This corresponds to a total of 28 fully configured or 56 partly configured QUADLOGI/O modules. The actual limit value depends on the type and the channel allocation of the I/O modules used. Typical configurations have about 10 to 20 QUADLOG I/O modules per PCS 7 QUADLOG DP/IO bus link.
The actual maximum configuration can be determined using the memory calculator. In doing so, the memory requirement of the module types used is to be multiplied by the respective number of modules. In addition, the memory requirement of the channel types used is to be multiplied by the respective number of channels. The value obtained by adding the two subtotals for modules and channels must not exceed 65 535 bytes.
Siemens ST PCS 7.2 · October 2009
3/7
3
© Siemens AG 2009
APACS+/QUADLOG migration Automation QUADLOG controller migration using DP/IO bus link and AS 417F Channel type
Memory calculator Enter the number of each module and channel type in the corresponding cell and calculate the total memory requirement.
Module type
3
Number of modules
Module memory requirement
Memory requirement per module type [bytes]
Number of channels
Channel size
Memory requirement per channel type [bytes]
ACDI
x
61
=0
ACDO
x
70
=0
ADIC
x
58
=0
AVDI
x
61
=0
CAAI
x
102
=0
CAIC
x
90
=0
CAIP
x
106
=0
CAI
x
623
=
0
CAIP
x
106
=0
CAM
x
731
=
0
CAOC
x
106
=0
CDM
x
731
=
0
CDDO
x
125
=0
CDO
x
731
=
0
CDOC
x
82
=0
EAM
x
623
=
0
CDSI
x
58
=0
IDM
x
623
=
0
CEDO
x
125
=0
ODM
x
623
=
0
CPIF
x
94
= 188
RTD
x
632
=
0
CPIT
x
58
=0
SAM
x
623
=
0
DPOC
x
70
=0
x
731
=
2 193
EACI
x
82
=0
x
635
=
0
EADO
x
61
=0
x
400
=
400
EAOC
x
94
=0
EAVI
x
82
=0
IDMI
x
50
=0
RIC
x
106
=0
RTD
x
114
=0
SADI
x
61
=0
SAIC
x
85
=0
SAOC
x
106
=0
SDOC
x
70
=0
SOEI
x
98
=0
SOEO
x
122
=0
TIC_
x
102
=0
VIC
x
98
=0
VPIF
x
94
=0
x
58
SDM+
3
VIM DPIOB
1
Total memory requirement for modules Total memory requirement for modules + channels
2 781 2 969
2
Available memory space
65 535
VPIT
Remaining memory space
62 566
Total memory requirement, channels
3/8
Siemens ST PCS 7.2 · October 2009
=0 = 188
© Siemens AG 2009
APACS+/QUADLOG migration Automation QUADLOG controller migration using DP/IO bus link and AS 417F Node-to-node redundancy with AS 417FH (redundancy station) SIMATIC PCS 7 AS 417FH Redundancy Station
DP/IO Bus Link
OVP
QUADLOG I/Os
OVP Transition board Redundancy cable
■ Integration The PCS 7 QUADLOG DP/IO bus link can only be used in plant configurations that are based on the SIMATIC PCS 7 V7.0 + SP1 process control system. It can be operated in these configurations together with the following components: • Automation systems AS 417F (single station) or AS 417 FH (redundancy station) • S7 F Systems V6.0 with S7 F-Lib V1.3 • SIMATIC Safety Matrix V6.1 S 7 F Systems V6.0 permits the implementation of safety-oriented applications by means of graphical engineering with the CFC (continuous function chart) using TÜV-tested function blocks with QUADLOG-specific functions. Even greater convenience during engineering and visualization is offered by the SIMATIC Safety Matrix V6.1 based on the CFC. According to the principle of a cause & effect matrix, this allows configuration by simply linking the events occurring in the course of the process with precisely defined reactions. S7 F Systems V6.0 and Safety Matrix Tool V6.1 can be obtained in the form of special SIMATIC PCS 7 Safety ES packages together with the SIMATIC PCS 7 engineering software V7.0 (see Catalog ST PCS 7, Section "Previous Versions, SIMATIC PCS 7 V7.0").
Sample configuration for node-to-node redundancy with AS 417FH (redundancy station)
In the case of node-to-node redundancy, two redundant PCS 7 QUADLOG DP/IO bus links are distributed across two separate mounting racks. In these former QUADLOG controller subracks they replace the existing QUADLOG-CPU. Each of the two redundant PCS 7 QUADLOG DP/IO bus links is connected via its transition board to one of two redundant PROFIBUS DP Master interfaces of the AS 417FH (redundancy station). For synchronization, the two redundant PCS 7 QUADLOG DP/IO bus links are to be connected additionally with a DP/IO bus redundancy cable via their transition boards. The configuration shown using the example of a non-redundant architecture can in principle also be transferred to the node-tonode redundancy (2 x 2 PCS 7 QUADLOG DP/IO bus links on one AS 417FH).
The scope of delivery of the PCS 7 QUADLOG DP/IO bus link includes a CD with the following content: • Hardware configuration file for parameterizing all QUADLOG I/O modules (for integration in the SIMATIC Manager of SIMATIC PCS 7) • Function block library with the channel drivers of the QUADLOG I/O modules as well as diagnostics blocks and faceplates • Documentation The software on this CD supports the integration of the PCS 7 QUADLOG DP/IO bus links and of the QUADLOG I/O modules into SIMATIC PCS 7. Together with the SIMATIC PCS 7 system software it enables: • Graphical hardware parameterization of the QUADLOG I/O modules with online diagnostics • Generation of hardware and software alarm messages for the QUADLOG I/O modules and the PCS 7 QUADLOG DP/IO bus link • Operation and monitoring, as well as monitoring of the PCS 7 QUADLOG DP/IO bus links and of the QUADLOG I/O modules
Siemens ST PCS 7.2 · October 2009
3/9
3
© Siemens AG 2009
APACS+/QUADLOG migration Automation QUADLOG controller migration using DP/IO bus link and AS 417F
■ Ordering data
■ Ordering data
Order No. 6EQ2 013-0CE00-0XA0
A)
DP/IO bus link transition board for the PROFIBUS DP interfacing of the PCS 7 QUADLOG DP/IO bus links to the AS 417F/FH Note: One transition board is required for each PCS 7 QUADLOG DP/IO bus link.
6EQ2 013-1CE00-0XA0
A)
DP/IO bus over-voltage protection for limiting the voltage on the PCS 7 QUADLOG DP/IO bus link to DC 30 V.
UPH: 39PSR6OVP
PCS 7 QUADLOG DP/IO bus link Type of delivery: • Electronic module • CD with function block library, configuration software and electronic documentation Additional components
3
Order No.
AS 417F/FH automation systems (bundles) Individual configuration of the AS 417F/FH bundles with the following basic data; completion of order numbers by selecting the preconfigured ordering units from Catalog ST PCS 7, Section "Previous versions, SIMATIC PCS 7 V7.0, safety-related automation systems" or by means of special configurators in the Industry Mall: SIMATIC PCS 7 AS single station / SIMATIC PCS 7 AS redundancy station) Single station AS 417F Preassembled and tested, memory card 16 MB RAM (up to about 3 000 POs), 1 x CPU 417-4H with S7 F Systems RT License (up to about 2 500 POs)
6ES7 654-8EN..-..B.
Redundancy station
DP/IO bus redundancy cable for the connection of two redundant PCS 7 QUADLOG DP/IO bus links for synchronization • 1 m long
6EQ2 013-0CE10-0XA0
A)
• 2 m long
6EQ2 013-0CE20-0XA0
A)
AS 417FH Preassembled and tested, memory card 16 MB RAM (up to about 3 000 POs), 2 x CPU 417-4H with S7 F Systems RT License (up to about 2 500 POs)
6ES7 656-8EN..-..B.
• 6 m long
6EQ2 013-0CE60-0XA0
A)
A) Subject to export regulations: AL: N, ECCN: EAR99H
Note: For additional SIMATIC PCS 7 ordering data, particularly for operator system and engineering system, see Catalog ST PCS 7, Section "Previous Versions, SIMATIC PCS 7 V7.0". The SIMATIC PCS 7 Engineering Software V7.0 is offered there in the form of special SIMATIC PCS 7 Safety ES Packages in the bundle with S7 F Systems V6.0 and Safety Matrix Tool V6.1.
3/10
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
APACS+/QUADLOG migration Operator control and monitoring PCS 7/APACS+ Operator System
■ Overview
■ Design The following software components are required depending on the configuration of a PCS 7/APACS+ operator system as single station or client/server combination (single or redundant): Required software
PCS 7 architecture OS Single Station
PCS 7/APACS+ OS single station pack V7.0 (2 000 POs)
Client/ server (non-redundant server)
Client/server (redundant server)
●
3 ●
PCS 7/APACS+ OS server pack V7.0 (2 000 POs)
●
PCS 7/APACS+ OS redundant server pack V7.0 (2 000 POs)
The software packs PCS 7/APACS+ OS offered for migration of APACS+ operator systems are tailored to the architecture of the SIMATIC PCS 7 operator system. They support single station systems (Single Stations) as well as multi-user systems with up to 12 servers/redundant pairs of servers and up to 32 clients. Data from different systems can be displayed in one process picture on the OS clients of a multiuser system, both from APACS/QUADLOG controllers on the M bus and from SIMATIC PCS 7 automation systems on the Industrial Ethernet. The multiclient architecture of the operator systems enables a client to retrieve data from different servers. With smaller systems it is possible to use a PCS 7 / APACS+ OS server with dual-channel functionality. This implements the communication with the APACS/QUADLOG controllers and the SIMATIC PCS 7 automation systems via two separate communication channels. A PCS 7/APACS+ plant configuration with automation systems (controllers), engineering system and operator system can be expanded by batch clients and batch servers for automation of batch processes using SIMATIC BATCH. Batch clients and OS clients can be operated together on one SIMATIC PCS 7 Industrial workstation or on separate basic hardware. Batch servers are usually set up on a separate SIMATIC PCS 7 industrial workstation, separated from the OS server.
●
PCS 7 OS Software Client V7.0 See section "OS Software V7.0" in Catalog ST PCS 7
●
When used with SIMATIC BATCH PCS 7/APACS+ SIMATIC BATCH Runtime License V7.0
●
●
● (2 licenses)
The number of process objects (PO) supplied with the software components in the table is expandable with SIMATIC PCS 7 PowerPacks V7.0 from section "OS Software V7.0" in Catalog ST PCS 7. In this section of the catalog it is also possible to select other software for PCS 7/ APACS+ operator systems. Appropriate basic hardware for a PCS 7/APACS+ operator station as a single station, server or client version can be found in Catalog ST PCS 7 in the section "SIMATIC PCS 7 Industrial Workstations V7.0". Communication between the APACS+/QUADLOG controllers on the M-Bus and the PCS 7/APACS+ OS on the Industrial Ethernet plant bus usually takes place via the Industrial Ethernet Module IEM (see last section of this chapter). In the case of small configurations with limited expansion, a PCS 7/APACS+ OS station can also be directly linked to an APACS+ MBUS segment by means of an APACS+/QUADLOG MBI PCI card.
Note: You can find information on the product range and the advanced functions of SIMATIC BATCH as well as ordering data for SIMATIC BATCH V7.0 in Catalog ST PCS 7.
Siemens ST PCS 7.2 · October 2009
3/11
© Siemens AG 2009
APACS+/QUADLOG migration Operator control and monitoring PCS 7/APACS+ Operator System PCS 7/APACS+ OS V7.0 (single station/server/redundant server) For the configuration of PCS 7/APACS+ OS operator stations the following software products are available: • PCS 7/APACS+ OS Single Station Pack V7.0 (2 000 POs) for a single station • PCS 7/APACS+ OS Server Pack V7.0 (2 000 POs)1) for one server • PCS 7/APACS+ OS Redundant Server Pack V7.0 (2 000 POs)1) for a redundant pair of servers
3
1) The standard OS client of SIMATIC PCS 7 V7.0 is used to expand PCS 7/APACS+ client/server architectures.
They are equipped with: • PCS 7 OS Software Runtime V7.0 incl. SP (2 000 POs, incl. 512 archive tags) • APACS+ OS channel for communication with the APACS+/QUADLOG controllers • Library with PCS 7/APACS+ OS icons and OS faceplates • WinCC/Redundancy and RS 232 connecting cable, 10 m (only PCS 7/APACS+ OS redundant server pack) The APACS+ OS channel DLL implements reliable communication with the APACS+/QUADLOG controllers using an original SIMATIC PCS 7 driver, and simultaneously permits communication with the AS 41x controllers by dual channel. It supports the Industrial Ethernet interfacing via the CP 1613 communications processor as well as the connection to the MBUS of APACS+ via Industrial Ethernet and IEM. The PCS 7/APACS+ OS icons and faceplates developed in line with the SIMATIC PCS 7 standard take into account the special properties of the APACS+/QUADLOG controllers. PCS 7/APACS+ SIMATIC BATCH Runtime License V7.0 Together with the APACS+ OS server channel DLL, the PCS 7/APACS+ SIMATIC BATCH runtime license allows exchange of runtime information between SIMATIC BATCH and an APACS+/QUADLOG controller. SIMATIC BATCH servers always communicate with the APACS+/QUADLOG controllers by means of a PCS 7/APACS+ OS server. Therefore a PCS 7/APACS+ SIMATIC BATCH Runtime license is required for each PCS 7/APACS+ OS Server which exchanges data with SIMATIC BATCH. Note: The PCS 7/APACS+ SIMATIC BATCH Runtime License V7.0 requires the installation of SIMATIC BATCH V7.0. The SIMATIC BATCH software V7.0 should be ordered additionally. Information about the SIMATIC BATCH product range and its advanced functions can be found in Catalog ST PCS 7 under "SIMATIC BATCH software".
3/12
Siemens ST PCS 7.2 · October 2009
■ Ordering data
Order No.
PCS 7/APACS+ Operator System PCS 7/APACS+ OS single station pack V7.0 (2 000 POs) English, executes with Windows XP Professional, single license for 1 installation Electronic documentation on CD "PCS 7/APACS+ Options V7.0" and PCS 7 Toolset DVD Type of delivery: • License key disk, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/APACS+ Options V7.0"
6EQ2 000-2AB07-3BA0
PCS 7/APACS+ OS server pack V7.0 (2 000 POs) English, executes with Windows 2003 Server, single license for 1 installation Electronic documentation on CD "PCS 7/APACS+ Options V7.0" and PCS 7 Toolset DVD Type of delivery: • License key disk, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/APACS+ Options V7.0"
6EQ2 000-2BB07-3BA0
PCS 7/APACS+ OS redundant server pack V7.0 (2 000 POs) English, executes with Windows 2003 Server, single license for 2 installations, incl. WinCC/Redundancy and RS 232 connecting cable, 10 m Electronic documentation on CD "PCS 7/APACS+ Options V7.0" and PCS 7 Toolset DVD Type of delivery: • 2 license key disks, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • RS 232 connecting cable, 10 m • CD "PCS 7/APACS+ Options V7.0"
6EQ2 000-2DB07-3BA0
© Siemens AG 2009
APACS+/QUADLOG migration Operator control and monitoring PCS 7/APACS+ Operator System
■ Ordering data
■ Ordering data
Order No.
PCS 7/APACS+ SIMATIC BATCH Runtime license V7.0 English, executes with Windows XP Professional/Server 2003, single license for 1 installation Type of delivery: • License key disk, certificate of license including terms and conditions
6EQ2 000-6XX07-2BB0
SIMATIC PCS 7 OS Software Client V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, floating license for 1 user (See section "OS Software V7.0" in Catalog ST PCS 7)
6ES7 658-2CX07-0YA5
APACS+/Quadlog MBI PCI card Permits direct interfacing of PCS 7/APACS+ OS to MBUSsegments for small configurationswith limited expansion
UPH:16413-16
Order No.
Software upgrade
A)
PCS 7/APACS+ OS runtime upgrade package from V6.0/V6.1 to 7.0 (OS single station or OS server) English, executes with Windows XP Professional/Server 2003, single license for 1 installation Electronic documentation on CD "PCS 7/APACS+ Options V7.0" and PCS 7 Toolset DVD Type of delivery: • License key disk, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/APACS+ Options V7.0"
6EQ2 000-2XX07-3BE0
3
A) Subject to export regulations: AL: N, ECCN: EAR99H
Siemens ST PCS 7.2 · October 2009
3/13
© Siemens AG 2009
APACS+/QUADLOG migration Engineering PCS 7/APACS+ OS Engineering Station
■ Design
3
The following software products are offered for the configuration of a PCS 7/APACS+ OS engineering station: • PCS 7/APACS+ OS Engineering Pack V7.0 for the OS engineering and the OS interfacing of the APACS+/QUADLOG controllers Alternative product versions: - Unlimited POs - without OS runtime license for productive operation as an operator station (2-hour OS test mode possible) - 2 000 POs - with OS runtime license (2 000 POs) for productive operation as operator station • PCS 7/APACS+ SIMATIC BATCH DBA Engineering V7.0 Optional package for configuration of SIMATIC PCS 7 OS and SIMATIC BATCH for the interfacing of APACS+/QUADLOG controllers; use of this additionally requires SIMATIC BATCH software V7.0 (to be ordered separately, see Catalog ST PCS 7, Section "SIMATIC BATCH Software V7.0") • PCS 7/APACS+ ES Libraries V6.1 Optional package for use of function blocks, icons and faceplates of the APACS+ Basic Application Library in plants with SIMATIC S7 400 controllers (AS 41x)
PCS 7/APACS+ OS DBA
PCS 7/APACS+ OS Engineering Pack V7.0 This software package is required for OS engineering and OS interfacing of the APACS+/QUADLOG controller. Depending on the application area, you can choose between two product versions whose licensing differs as follows: • PCS 7/APACS+ OS Engineering Pack V7.0 (unlimited POs), for an exclusive engineering station with unlimited OS engineering license; in this version the use as an operator station is restricted to a 2-hour test mode. Continuous use in productive operation is not possible. • PCS 7/APACS+ OS Engineering Pack V7.0 (2 000 POs), for a combines engineering/operator station; in addition to an OS engineering license for 2 000 POs, this version also includes an OS runtime licenses for 2 000 POs (incl. 512 archive tags). The number of process objects (PO) is expandable with SIMATIC PCS 7 PowerPacks from Catalog ST PCS 7, section "ES Software V7.0". Both product versions contain the components listed below: • SIMATIC PCS 7 engineering software for OS V7.0 (including SP) with the licenses described above in accordance with Catalog ST PCS 7, Section "ES Software V7.0" • PCS 7/APACS+ OS DBA Database Engineering Package for the migration of user data. • APACS+ OS Server Channel DLL for communication with APACS+/QUADLOG controllers • PCS 7/APACS+ OS library with OS icons and OS faceplates • OPC Engineering plug-in for interfacing third-party controllers (e.g. Allen-Bradley) Further engineering software for installation on this engineering station can be ordered using Catalog ST PCS 7, Section "ES software V7.0". Appropriate basic hardware for a PCS 7/APACS+ Engineering Station can be found in the section "SIMATIC PCS 7 Industrial Workstation" of Catalog ST PCS 7.
3/14
Siemens ST PCS 7.2 · October 2009
Database Automation (DBA) tool for generation of the PCS 7 OS database
A core component for the PCS 7/APACS+ OS Engineering is the Database Automation PCS 7/APACS+ OS DBA. This automatically generates the OS database with the display hierarchy, required tags, alarm messages and alarm priorities as well as the specific block icons and faceplates from the data of the APACS+/QUADLOG controllers. The display hierarchy is the basis for navigation between the process pictures and for alarm management. PCS 7/APACS+ OS DBA automatically positions the type-specific block icons, e.g. for controllers or analog inputs (AI), in the generated process pictures. These block icons are linked to the associated function blocks and faceplates through the database. Manual configuration is mainly limited to the design and positioning of the static graphic elements, e.g. tubes or tanks. APACS+ OS Server Channel DLL The APACS+ OS server channel DLL implements reliable communication with the APACS+/QUADLOG controllers using an original SIMATIC PCS 7 driver, and simultaneously permits communication with the AS 41x controllers by dual channel. It supports the Industrial Ethernet interfacing of APACS+/QUADLOG controllers using the CP 1613 communications processor in conjunction with the Industrial Ethernet Module IEM, as well as direct connection to the MBUS using an APACS+/QUADLOG MBI PCI card.
© Siemens AG 2009
APACS+/QUADLOG migration Engineering PCS 7/APACS+ OS Engineering Station PCS7/APACS+ OS library The PCS7/APACS+ OS library contains the following types of icons and faceplates: Types of icons and faceplates of the PCS 7/APACS+ OS library Process Control Functions
Single Loop Single Loop SS External Setpoint Ratio Setpoint Cascade Primary Secondary
Process I/O Functions
Analog Alarm Discrete Alarm
Controller Diagnostics
Resource Status
Process Objects
Block Valve 1 Out Block Valve 2 Out Valve A Valve A Alarm Motor 1 Out Motor 2 Out Motor A Motor A Alarm
PCS 7/APACS+ ES libraries V6.1 for SIMATIC PCS 7 AS 41x controller Optional package for use of function blocks, icons and faceplates of the APACS+ Basic Application Library in plants with SIMATIC S7-400 controllers (AS 41x) The optional package PCS 7/APACS+ ES Libraries contains: • ES library with preconfigured PID controllers, motor blocks and valve blocks for SIMATIC S7-400 controllers • Associated block icons and faceplates for the PCS 7 Operator System. It permits utilization of the APACS+ Basic Application Library functionality also in conjunction with SIMATIC PCS 7 AS 41x automation systems. These can then be operated and visualized like APACS+/QUADLOG controllers. The PCS7/APACS+ ES library contains the following AS blocks with associated OS faceplates: AS blocks of the PCS 7/APACS+ ES library Process Control Functions
The PCS 7/APACS+ OS icons and faceplates developed in line with the SIMATIC PCS 7 standard take into account the special properties of the APACS+/QUADLOG controllers.
Single Loop Single Loop SS External Setpoint Ratio Setpoint Cascade Primary Secondary
Process I/O Functions
Analog Alarm Discrete Alarm
OPC engineering plug-in
Process Objects
Block Valve 1 Out Block Valve 2 Out Valve A Valve A Alarm Motor 1 Out Motor 2 Out Motor A Motor A Alarm
An additional component in DBA enables engineering of OPC connections to any third-party systems, e.g. for interfacing AllenBradley controllers. In addition to process values, this can be used to also integrate messages and alarms from third-party systems into the PCS 7 OS database. Analogous to APACS+, the OPC component supports automatic generation of the OS plant hierarchy as well as positioning of the corresponding block icons. The engineering overhead for integrating third-party systems can thus be drastically reduced. PCS 7/APACS+ SIMATIC BATCH DBA Engineering V7.0 Optional package for configuration of PCS 7 OS and SIMATIC BATCH for interfacing of APACS+/QUADLOG controllers The optional package PCS 7/APACS+ SIMATIC BATCH DBA Engineering contains: • Licenses with which the batch information for a batch project saved in the APACS+ Engineering System 4-mation can be imported into DBA and translated for SIMATIC BATCH. • License for exchange of information between SIMATIC BATCH and a PCS 7/APACS+ OS Server during runtime Note: A prerequisite for the use of the PCS 7/APACS+ SIMATIC BATCH Runtime License V7.0 is the installation of SIMATIC BATCH V7.0 (including SP). The SIMATIC BATCH software should be ordered separately. The ordering data for SIMATIC BATCH V7.0 (including SP) can be found in Catalog ST PCS 7, in the section "SIMATIC BATCH software V7.0".
Siemens ST PCS 7.2 · October 2009
3/15
3
© Siemens AG 2009
APACS+/QUADLOG migration Engineering PCS 7/APACS+ OS Engineering Station
■ Ordering data
Order No.
PCS 7/APACS+ OS Engineering Software for exclusive engineering station with unlimited OS engineering license Without OS Runtime license for productive operation as an operator station (2-hour OS test mode possible)
3
PCS 7/APACS+ OS engineering pack V7.0 (unlimited POs) English, executes with Windows XP Professional, floating license for 1 user Electronic documentation on CD "PCS 7/APACS+ Options V7.0" and PCS 7 Toolset DVD Type of delivery: • License key disk, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/APACS+ Options V7.0"
6EQ2 000-2EB07-3BA5
Software for combined engineering/operator station with OS engineering license for 2 000 POs With OS runtime license (2 000 POs) for productive operation as operator station PCS 7/APACS+ OS engineering pack V7.0 (2 000 POs) English, executes with Windows XP Professional, floating license for 1 user Electronic documentation on CD "PCS 7/APACS+ Options V7.0" and PCS 7 Toolset DVD Type of delivery: • License key disk, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/APACS+ Options V7.0" Note: The number of process objects (PO) is expandable with SIMATIC PCS 7 PowerPacks V7.0 from Catalog ST PCS 7, section "ES Software V7.0".
3/16
6EQ2 000-3EB07-3BA5
Siemens ST PCS 7.2 · October 2009
■ Ordering data
Order No.
Options PCS 7/APACS+ SIMATIC BATCH DBA Engineering V7.0 English, executes with Windows XP Professional, single license for 1 installation Type of delivery: • License key disk, certificate of license including terms and conditions Note: For the use of this product you also require SIMATIC BATCH software V7.0 (incl. SP) from Catalog ST PCS 7, Section "SIMATIC BATCH Software V7.0".
6EQ2 000-5XX07-2BB0
PCS 7/APACS+ ES libraries V6.1 for SIMATIC PCS 7 AS 41x controller English, executes with Windows XP Professional, floating license for 1 user Type of delivery: • License key disk, certificate of license including terms and conditions • CD "PCS 7/APACS+ ES libraries V6.1"
6EQ2 000-1AX16-2BB5
Upgrade package PCS 7/APACS+ OS engineering upgrade package from V6.0/6.1 to V7.0 English, executes with Windows XP Professional, floating license for 1 user Electronic documentation on CD "PCS 7/APACS+ Options V7.0" and PCS 7 Toolset DVD Type of delivery: • 2 license key disks (250 2 000 POs and 2 000 - unlimited POs), certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/APACS+ Options V7.0"
6EQ2 000-1XX07-3BE5
© Siemens AG 2009
APACS+/QUADLOG migration Communication Industrial Ethernet Module (IEM)
■ Overview
■ Technical specifications Industrial Ethernet Module Design and equipment features Design
Rack-mountable device with rugged metal enclosure, suitable for wall and portrait mounting
Degree of protection to EN 60529
IP20
CPU • Processor
Intel Core 2 Duo T5500, 1.66 GHz
• Front Side Bus
667 MHz
• Second Level Cache
2 MB
Work memory
1 GB DDR2-667 SDRAM (SO-DIMM modules)
Chipset
Mobile Intel 945 GM Express + ICH7R
3
MBI/MBUS communications module 16413-16 PCI 5v card Drives
The Industrial Ethernet Module (IEM) is a flexible network gateway for APACS+/QUADLOG systems. The IEM supports the three following architectures: • Peer-to-peer communication between ACM/CCM and S7-41x controllers The IEM offers an interface between the MBUS of APACS+/QUADLOG systems and the SIMATIC PCS 7 Industrial Ethernet plant bus. • Peer-to-peer communication between ACM/CCM controllers on different MBUS segments The communications function blocks supplied support the forwarding of the following APACS+ data types between the controllers: - REAL - BOOLEAN - WORD • MBUS-to-Ethernet communication conversion for APACS+/QUADLOG systems The IEM can replace the RNI (rack-mounted network interface) in existing systems. When using the standard MBUS communication, the OS Engineering Station, OS Single Station or OS Server may be located up to 168 m from the APACS+/QUADLOG rack. This restriction does not apply to system configurations with the IEM. In system architectures with higher availability requirements, redundant network gateways can also be implemented on the basis of the IEM.
Hard disk
No
CompactFlash (CF) Card
front panel, CF card can be plugged in from the outside
Optical drives
No
Floppy disk drive
No
Interfaces Ethernet
2 x 10/100/1000 Mbit/s (RJ45) integrated
PROFIBUS DP
No
USB 2.0
4 terminals, 2 of which high current
Serial
1 x COM1
Operating system and software licenses Operating system
Microsoft Windows XP embedded on 2 GB CF Card
Licenses
SIMATIC NET/APACS+ NIM32
Power supply
110/230 V AC, power cable for the USA
Climatic conditions in operation Temperature
+5 ... +45 °C
Relative humidity
5 ... 80% at 25 °C (no condensation)
Dimensions and weights Dimensions (W x H x D in mm)
297 x 267 x 80
Weight
approx. 7 kg
■ Ordering data Note: Fail-safe communication is not currently available for the QUADLOG controllers (available soon).
Any USB flash memory medium (min. 1 MB) is required in addition for the IEM configuration, e.g. SIMATIC PC USB-FlashDrive.
Order No.
Industrial Ethernet Module IEM for peer-to-peer communication
6EQ2 020-0AB12-5XX0
C)
6ES7 648-0DC40-0AA0
A)
Accessories Flash memory medium for IEM configuration: SIMATIC PC USB FlashDrive 2 GB, USB 2.0, metal enclosure, bootable
A) Subject to export regulations: AL: N, ECCN: EAR99H C) Subject to export regulations: AL: N, ECCN: 5D992
Siemens ST PCS 7.2 · October 2009
■
3/17
© Siemens AG 2009
APACS+/QUADLOG migration
3
3/18
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
SIMATIC PCS / TISTAR migration
4
4/2
Introduction
4/4
PCS 7/505 OS Engineering Station
4/6
PCS 7/505 Operator System
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
SIMATIC PCS / TISTAR migration Introduction
■ Overview Engineering system
SIMATIC PCS 7 OS clients
APT engineering
PCS 7/505 OS server
PCS 7/505 OS server
PCS 7 OS server
(dualchannel)
Industrial Ethernet (single/redundant) SIMATIC 505 CP 1434 TF
SIMATIC 505 CP 1434 TF
4
RBE
Ethernet SINEC H1 TF (single/redundant)
AS 414FH/ AS 417FH
RBE ET 200M ET 200M
AS 414 / AS 416 / AS 417
ET 200M
DP/PA link
ET 200M
PROFIBUS
Field devices
Configuration example of migration of SIMATIC PCS/TISTAR systems
A large number of SIMATIC PCS/TISTAR systems has been installed worldwide since 1991. These systems represent a wealth of hardware, user software and know-how accumulated by operating and maintenance personnel. In order to retain the installed SIMATIC PCS/TISTAR basic systems and to enhance value, Siemens has developed an effective migration strategy based on the innovative SIMATIC PCS 7 process control system. This strategy enables the existing system to migrate efficiently and profitably, without having to replace any controllers, I/O devices or their wiring, and without any loss of associated investment in the system configuration.
■ Benefits Through migration with SIMATIC PCS 7 Engineering and Operator Systems it is possible to significantly increase the functionality and efficiency of process control systems based on 505 controllers. In addition, the ability of the PCS 7/505 operator systems to communicate with both 505 controllers and SIMATIC PCS 7 controllers AS 41x offers exceptional perspectives for future plant expansions. At the same time, SIMATIC PCS 7 customers benefit from Totally Integrated Automation (TIA), a seamless offering of perfectly matched products, systems, and solutions for all hierarchy levels of industrial automation. This is associated with continuous development, long-term support and worldwide service. From this viewpoint, the migration with SIMATIC PCS 7 pays for itself several times over - it safeguards existing investment in control technology, makes the plants more efficient and productive, and extends their life on a cost-effective basis.
4/2
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
SIMATIC PCS / TISTAR migration Introduction
■ Design The following migration products are available for migration of SIMATIC PCS/TISTAR systems with SIMATIC PCS 7 V7.0: • PCS 7/505 OS engineering pack V7.0 (unlimited POs) for an exclusive engineering station with the functionality for the OS engineering and the OS connection of the 505 controller, consisting of: - SIMATIC PCS 7 OS Engineering V7.0 (incl. Service Pack) - PCS 7/505 OS DBA V7.0 - 505 OS Server Channel DLL - Library with OS function block icons and OS faceplates • PCS 7/505 OS Engineering Pack V7.0 (2 000 POs) for a combined engineering/operator station with the functionality for the OS engineering, the OS interfacing of the 505 controllers and the OS runtime operation, consisting of: - SIMATIC PCS 7 OS Engineering V7.0 (incl. Service Pack) - PCS 7/505 OS DBA V7.0 - 505 OS Server Channel DLL - Library with OS function block icons and OS faceplates • PCS 7/505 OS Server Pack V7.0 for operation and monitoring of 505 controllers via PCS 7/505 operator system, configured as client/server system without PCS 7/505 OS server redundancy • PCS 7/505 OS Redundant Server Pack V7.0 for operation and monitoring of 505 controllers via PCS 7/505 operator system, configured as client/server system with redundant PCS 7/505 OS servers • PCS 7/505 OS Single Station Pack V7.0 for operation and monitoring of 505 controllers via PCS 7/505 operator system, configured as single station
■ Options Converting OS user software The modern DBA technology of Siemens permits fast and secure implementation of your user software. Your investment in the configuration of the existing system is therefore safeguarded. It goes without saying that we also offer this conversion as a service. But you can call upon the services of our experienced migration specialists not only for this reason, but also when generating new graphics. We would be pleased to provide you with an individual quotation. For quotations and additional information, please contact your regional Siemens representative.
■ More information You can find detailed information, ordering data and technical specifications on individual migration products in the following sections "PCS 7/505 Engineering Station" and "PCS 7/505 Operator System". You can find additional information in the Internet at: www.siemens.com/simatic-pcs7/migration
The PCS 7/505 OS Client V7.0 is identical with the SIMATIC PCS 7 OS Client V7.0. Software upgrade If you have already modernized the PCS/TISTAR system with PCS 7/505 OS migration products V6.1, you can upgrade the PCS 7/505 engineering and operator stations to V7.0 using the following upgrade software: • PCS 7/505 OS Upgrade Package Engineering from V6.1 to V7.0 to upgrade a PCS 7/505 OS engineering station from V6.1 to V7.0 • PCS 7/505 OS Upgrade Package Runtime from V6.1 to V7.0 to upgrade a PCS 7/505 OS single station, a PCS 7/505 OS server or a redundant pair of PCS 7/505 OS servers from V6.1 to V7.0 • PCS 7 OS Client/SFC Visualization Upgrade Package from V6.0/6.1 to V7.0 to upgrade a PCS 7/505 OS client from V6.1 to V7.0 Multi-client and dual-channel functionality Data from different systems can be displayed on the OS clients in a process picture: • Data from 505 controllers on the Ethernet SINEC H1 TF • Data from SIMATIC PCS 7 automation systems on the SIMATIC PCS 7 plant bus Industrial Ethernet. The multi-client architecture of the operator systems enables a client to retrieve data from different servers. With smaller systems it is possible to use a PCS 7/505 OS server with dual-channel functionality. This implements the communication with the 505 controllers and the SIMATIC PCS 7 automation systems via two separate channels DLLs.
Siemens ST PCS 7.2 · October 2009
4/3
4
© Siemens AG 2009
SIMATIC PCS / TISTAR migration PCS 7/505 OS Engineering Station
■ Design
4
PCS 7/505 OS Engineering Pack V7.0
PCS 7/505 OS DBA V7.0
This software package is required for the configuration of the PCS 7/505 operator station. Depending on the application area, you can choose between two product versions whose licensing differs as follows: • PCS 7/505 OS engineering pack V7.0 (unlimited POs), for an exclusive engineering station with unlimited OS engineering license; in this version the use as an operator station is restricted to a 2-hour test mode. Continuous use in productive operation is not possible. • PCS 7/505 OS engineering pack V7.0 (2 000 POs), for a combined engineering/operator station; in addition to an OS engineering license for 2 000 POs, this version also includes an OS runtime license for 2 000 POs. The number of process objects (PO) is expandable with SIMATIC PCS 7 PowerPacks V7.0 from Catalog ST PCS 7, section "ES Software V7.0".
A core component for the PCS 7/505 OS engineering is the database automation software PCS 7/505 OS DBA. This component automatically generates the OS database with the display hierarchy, required tags, interrupts, alarm messages and alarm priorities as well as the specific block icons and faceplates from the user software of the controller. The display hierarchy is the basis for navigation between the process pictures, for alarm management, and for implementing security measures. PCS 7/505 OS DBA automatically places the type-specific block icons, e.g. controller or analog input(AI), in the generated process pictures. These icons are linked to the corresponding function blocks and faceplates through the database. Manual configuration is mainly limited to the design and positioning of the static graphic elements, e.g. tubes or tanks.
Both product versions contain the components listed below: • SIMATIC PCS 7 engineering software for OS V7.0 (including Service Pack) with the licenses described above in accordance with Catalog ST PCS 7, Section "ES Software V7.0" • PCS 7/505 OS DBA V7.0 Database Engineering Package for the migration of user data • 505 OS Server Channel DLL The 505 OS server channel DLL implements reliable communication with the 505 controllers using a SIMATIC PCS 7 driver, and additionally permits simultaneous communication with the AS 41x automation systems. It supports the Industrial Ethernet interface via the CP 1613 communications processor. • Library with PCS 7/505 OS block icons and OS faceplates Additional SIMATIC PCS 7 engineering software for a PCS 7/505 engineering station can be ordered using Catalog ST PCS 7, Section "ES software V7.0". Appropriate basic hardware for a PCS 7/505 Engineering Station can be found in the section "SIMATIC PCS 7 Industrial Workstations V7.0" of Catalog ST PCS 7.
4/4
Siemens ST PCS 7.2 · October 2009
PCS 7/505 OS library Symbols and faceplates of the PCS 7/505 OS library Process I/O functions
• AI • AO • DI • DI10 • DO • DO10
Process objects
• VLV1 • VLV2 • RMTR • MTR1 • MTR2
Mathematical functions
• CALC • IVAR • TMR
Control functions
• CTR • LOOP
Display functions
• TEXT
The PCS 7/505 OS symbols and faceplates developed in line with the SIMATIC PCS 7 standard take into account the special properties of the 505 controllers.
© Siemens AG 2009
SIMATIC PCS / TISTAR migration PCS 7/505 OS Engineering Station
■ Ordering data
■ Ordering data
Order No.
PCS 7/505 OS engineering pack V7.0 (unlimited POs) 1 language (English), executes with Windows XP Professional, floating license for 1 user Electronic documentation on CD "PCS 7/505 Option V7.0" and PCS 7 Toolset DVD Type of delivery: • License key memory stick, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/505 Option V7.0"
6EQ2 000-3ED07-3BA5
Order No.
Software upgrade
Software for exclusive engineering station with unlimited OS engineering license (not suitable for productive operation as an operator station; 2-hour OS test mode possible) B)
PCS 7/505 OS engineering upgrade package from V6.1 to V7.0 1 language (English), executes with Windows XP Professional, floating license for 1 user Type of delivery: • 2 license key memory sticks, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/505 Option V7.0"
6EQ2 000-3XX07-3BE5
B)
4
B) Subject to export regulations: AL: N, ECCN: EAR99S
Software for combined engineering/operator station with 2 000 OS engineering and runtime POs (can be used as operator station for productive operation) PCS 7/505 OS engineering pack V7.0 (2 000 POs) 1 language (English), executes with Windows XP Professional, floating license for 1 user Electronic documentation on CD "PCS 7/505 Option V7.0" and PCS 7 Toolset DVD Type of delivery: • License key memory stick, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/505 Option V7.0"
6EQ2 000-3EE07-3BA5
B)
Siemens ST PCS 7.2 · October 2009
4/5
© Siemens AG 2009
SIMATIC PCS / TISTAR migration PCS 7/505 Operator System
■ Overview The software packs PCS 7/505 OS offered for migration of existing SIMATIC PCS/TISTAR systems are tailored to the architecture of the SIMATIC PCS 7 operator systems. They support singleuser systems (Single Stations) as well as multi-user systems with up to 12 servers/redundant pairs of servers and up to 32 clients.
4 ■ Design The following software components are required depending on the configuration of a PCS 7/505 operator system as single station or client/server combination (single or redundant server): Required software
SIMATIC PCS 7 architecture OS Single Station
PCS 7/505 OS Single Station Pack V7.0 PCS 7/505 OS Server Pack V7.0
Client/ Client/server server (redundant (non-redunserver) dant server)
● ● ●
PCS 7/505 OS Redundant Server Pack V7.0 PCS 7 OS Software Client V7.0 See Catalog ST PCS 7, section "OS Software V7.0"
●
●
PowerPacks as well as further software for PCS 7/505 operator systems can be ordered from the Catalog ST PCS 7, in the section "OS Software V7.0". Appropriate basic hardware for a PCS 7/505 operator station as a single station, server or client version can be found in Catalog ST PCS 7 in the section "SIMATIC PCS 7 Industrial Workstations V7.0".
4/6
Siemens ST PCS 7.2 · October 2009
PCS 7/505 OS Packs V7.0 (single station/server/redundant server) The PCS 7/505 OS Packs contain: • PCS 7 OS software runtime V7.0 incl. Service Pack (PO 2000) for one OS single station, one OS server or two redundant OS servers (incl. WinCC/Redundancy and RS 232 connecting cable, 10 m) • 505 OS Channel DLL (Single Station or Server) for communication with the 505 controllers • Library with PCS 7/505 OS function block icons and OS faceplates The 505 OS Channel DLL (single station or server) represents an original SIMATIC PCS 7 driver for reliable communication with the 505 controllers. This channel also supports the Industrial Ethernet interface via the CP 1613 communications processor. The PCS 7/505 OS icons and OS faceplates developed in line with the SIMATIC PCS 7 standard take into account the special properties of the 505 controllers.
© Siemens AG 2009
SIMATIC PCS / TISTAR migration PCS 7/505 Operator System
■ Ordering data
■ Ordering data
Order No.
PCS 7/505 OS single station pack V7.0 (PO 2000) 1 language (English), executes with Windows XP Professional, Single License for 1 installation Electronic documentation on CD "PCS 7/505 Option V7.0" and PCS 7 Toolset DVD Type of delivery: • License key memory stick, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. service pack), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/505 Option V7.0"
6EQ2 000-3AE07-3BA0
PCS 7/505 OS server pack V7.0 (PO 2000) 1 language (English), executes with Windows Server 2003, single license for 1 installation Type of delivery: • License key memory stick, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. service pack), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/505 Option V7.0"
6EQ2 000-3BE07-3BA0
PCS 7/505 OS redundant server pack V7.0 (2 000 POs) 1 language (English), executes with Windows Server 2003, single license for 2 installations, incl. WinCC/Redundancy and RS 232 connection cable, 10 m Type of delivery: • License key memory stick with 2 licenses, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. service pack), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/505 Option V7.0" • RS 232 connecting cable, 10 m
6EQ2 000-3DE07-3BA0
SIMATIC PCS 7 OS Software Client V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, floating license for 1 user (See Catalog ST PCS 7, section "OS Software V7.0")
6ES7 658-2CX07-0YA5
B)
B)
Order No.
Software upgrade PCS 7/505 OS Runtime upgrade package from V6.1 to V7.0 for OS Single Station or OS Server 1 language (English), executes with Windows XP Professional/Server 2003, Single License for 1 installation Type of delivery: • License key memory stick, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. service pack), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/505 Option V7.0"
6EQ2 000-3XX07-3BE0
SIMATIC PCS 7 OS client/ SFC visualization upgrade package V6.0/V6.1 to V7.0 5 languages (German, English, French, Italian, Spanish), executes with Windows XP Professional, floating license for 1 user (See Catalog ST PCS 7, section "Upgrades from SIMATIC PCS 7 V6.x to V7.0")
6ES7 652-5CX07-0YE5
B)
4
B) Subject to export regulations: AL: N, ECCN: EAR99S
■
B)
Siemens ST PCS 7.2 · October 2009
4/7
© Siemens AG 2009
SIMATIC PCS / TISTAR migration
4
4/8
Siemens ST PCS 7.2 · October 2009
5
© Siemens AG 2009
OpenPMC migration 5/2
Introduction
5/4
PCS 7/OPMC OS Engineering Station
5/5
PCS 7/OPMC Operator System
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
OpenPMC migration Introduction
■ Overview Engineering system
SIMATIC PCS 7 OS clients
PCS 7/F2K OS server with SIMATIC IT Historian, OPC Server
PCS 7/F2K OS server (dual-channel)
SIMATIC IT Management Console
PCS 7 OS server Industrial Ethernet (single/redundant)
Ethernet (TCP/IP)
OpenPMC Controller
5
AS 414FH/ AS 417FH
ET 200M
ET 200M
ET 200M
ET 200M
AS 414 / AS 416 / AS 417
ET 200M
DP/PA link
ET 200M
Field devices PROFIBUS
PROFIBUS
Configuration example of migration of OpenPMC systems
A large number of OpenPMC systems have been installed worldwide. These systems represent a wealth of hardware, user software and know-how accumulated by operating and maintenance personnel. In order to retain the installed OpenPMC systems and to increase their value, Siemens has developed an effective migration strategy based on the innovative SIMATIC PCS 7 process control system. This strategy allows OpenPMC customers to replace their existing systems by state-of-the-art SIMATIC PCS 7 systems, with continued use of their OpenPMC controllers and the installed field technology. At the same time, customers can use SIMATIC PCS 7 AS 41x controllers and SIMATIC process I/Os for plant expansions.
5/2
Siemens ST PCS 7.2 · October 2009
When migrating Siemens OpenPMC systems with SIMATIC PCS 7 V7.0, existing OpenPMC operator stations (SIMATIC IT Historian Server and Clients) are replaced by SIMATIC PCS 7 operator systems (Single Stations or Client/Server systems). The OS Single Stations and the OS Servers of such PCS 7/OPMC operator systems can be operated in redundant or individual mode. The OPC server of SIMATIC IT Historian is used for data exchange between OpenPMC controllers and PCS 7/OPMC servers. The engineering of the PCS 7/OPMC operator systems is based on the data base automation (DBA) software. The data source for DBA is the SIMATIC IT Historian Management Console, which is still used further for configuration of the OpenPMC controllers.
© Siemens AG 2009
OpenPMC migration Introduction
■ Design The following migration products are available for upgrading of OpenPMC systems with SIMATIC PCS 7: • PCS 7/OPMC OS Engineering Pack V7.0 for the OS engineering, consisting of: - SIMATIC PCS 7 Engineering Software V7.0 - PCS 7/OPMC OS DBA V7.0 • PCS 7/OPMC OS Single Station Pack V7.0 for a single station, consisting of: - SIMATIC PCS 7 OS Single Station Software V7.0 incl. Runtime license for 1 operator station • PCS 7/OPMC OS Server Pack V7.0 for an individual server, consisting of: - SIMATIC PCS 7 OS Software Server V7.0 incl. Runtime license for a non-redundant PCS 7/OPMC OS Server • PCS 7/OPMC OS Redundant Server Pack V7.0 for a redundant pair of servers, consisting of: - SIMATIC PCS 7 OS Redundant Software Server V7.0 incl. Runtime license for a redundant pair of PCS 7/OPMC OS servers Multi-client and dual-channel functionality Data from different systems can be viewed on the OS clients in a process picture: • Data from OpenPMC controllers on the OpenPMC Ethernet bus • Data from SIMATIC PCS 7 automation systems on the SIMATIC PCS 7 plant bus Industrial Ethernet.
■ Options Converting OS user software The modern DBA technology of Siemens permits fast and secure implementation of your user software. You then benefit from consistent software quality, reliability and verifiability. It goes without saying that we also offer this conversion as a service. We leave you to decide whether you wish to convert your user software yourself or whether you wish to commission our experienced migration specialists. We would be pleased to provide you with an individual quotation. For quotations and additional information, please contact your regional Siemens representative.
■ More information You can find detailed information, ordering data and technical specifications on individual migration products in the following sections "PCS 7/OPMC Engineering Station" and "PCS 7/OPMC Operator System". You can find additional information in the Internet at: www.siemens.com/simatic-pcs7/migration
5
The multi-client architecture of the operator systems enables a client to retrieve data from different servers. With smaller quantity frameworks, it is also possible to use a PCS 7/OPMC OS Server with dual-channel functionality. An individual PCS 7/OPMC OS Server implements the communication not only with the OpenPMC controllers, but also with the SIMATIC PCS 7 automation systems.
Siemens ST PCS 7.2 · October 2009
5/3
© Siemens AG 2009
OpenPMC migration PCS 7/OPMC OS Engineering Station
■ Design
■ Ordering data
PCS 7/OPMC OS Engineering Pack V7.0 The PCS 7/OPMC OS Engineering Pack software V7.0 is required in order to configure a PCS 7/OPMC operator station. This software package comprises the following components: • SIMATIC PCS 7 Engineering Software for OS V7.0, unlimited POs (see Section "ES software V7.0" of Catalog ST PCS 7) • PCS 7/OPMC OS DBA V7.0 Database Engineering Package for migration of user data. Contains examples of OpenPMC OS faceplates for use with SIMATIC PCS 7. • Defined Type Editor / Defined Type Instance Editor For generation of templates and instances of user function block data structures The SIMATIC IT Historian V6.1 SP1 OPC server is not included in this package. Additional engineering software packages can be ordered in the Section "ES Software V7.0" of Catalog ST PCS 7 and can be installed on an engineering station.
5
Appropriate basic hardware for a PCS 7/OPMC Engineering Station can be found in the section "SIMATIC PCS 7 Industrial Workstations V7.0" of Catalog ST PCS 7. PCS 7/OPMC OS DBA V7.0 This OS Engineering package contains the Data Base Automation software. OpenPMC does not possess standard icons, faceplates and tag structures. With OpenPMC projects, these objects are created by the users themselves. The database automation software is used to map the project-specific tag structures in OpenPMC onto corresponding SIMATIC PCS 7 tag structures. PCS 7/OPMC OS DBA contains three example icons, faceplates and tag structures. In this way, project engineers can learn how the necessary icon and function block libraries and tag structures are to be generated for their project. As soon as the SIMATIC PCS 7 tag structures have been configured with the database automation software and the SIMATIC PCS 7 icon and function block libraries have been generated with the PCS 7 Graphics Designer, the database automation software automatically generates the SIMATIC PCS 7 OS database with the display hierarchy, required tags, interrupts, alarm messages and alarm priorities as well as the specific function block icons and faceplates. The display hierarchy is the basis for navigation between the process pictures, for alarm management, and for implementation of safety measures. PCS 7/OPMC OS DBA automatically places the type-specific block icons, e.g. controller or analog input, in the generated process pictures. These icons are linked to the corresponding function blocks and faceplates through the database. Manual configuration is mainly limited to the design and positioning of the static graphic elements, e.g. tubes or tanks.
5/4
Siemens ST PCS 7.2 · October 2009
PCS 7/OPMC OS Engineering Pack V7.0 Unlimited POs, 2 languages (English, Italian), executes with Windows XP Professional/Server 2003, floating license for 1 user Electronic documentation on CD "PCS 7/OPMC Options Version 7.0" and on PCS 7 Toolset DVD Type of delivery: License key disk, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVD, Microsoft SQL Server 2005, supplementary CDs/DVDs (e.g. Microsoft service packs and tools); CD "PCS 7/OPMC Options Version 7.0"
Order No. 6EQ2 008-1BA07-3BA5
© Siemens AG 2009
OpenPMC migration PCS 7/OPMC Operator System
■ Overview The software components offered for migration of existing OpenPMC operator systems are tailored to the architecture of the SIMATIC PCS 7 operator system. They support single-user systems (Single Stations) as well as multi-user systems with up to 12 servers/redundant pairs of servers and up to 32 clients.
PCS 7/OPMC faceplate for a PID loop block
■ Design The following software components are required depending on the configuration of a PCS 7/OPMC operator system as single station or client/server combination (single or redundant): Required software
SIMATIC PCS 7 architecture OS Single Station
PCS 7/OPMC OS Single Station Pack V7.0 PCS 7OPMC OS Server Pack V7.0
Client/ Server single
● ● ●
PCS 7/OPMC OS Redundant Server Pack V7.0 PCS 7 OS Software Client V7.0 See section "OS Software V7.0" in Catalog ST PCS 7
Client/ Server redundant
●
PCS 7/OPMC OS Packs (Single Station/Server/Redundant Server) The PCS 7/OPMC OS Packs contain the following components: • SIMATIC PCS 7 OS Software Runtime (250 POs, incl. 512 archive tags) • Library with 3 PCS 7/OPMC OS icons and OS faceplates • WinCC/Redundancy and RS 232 connection cable, 10 m (only for redundant OS Server) The PCS 7/OPMC OS function block icons and OS faceplates are matched to the special properties of the OpenPMC controllers.
●
PowerPacks as well as further software for PCS 7/OPMC operator systems can be ordered from the section "OS Software V7.0" of the Catalog ST PCS 7. Appropriate basic hardware for the configuration of an operator station as a PCS 7/OPMC OS single station, PCS 7/OPMC OS server or PCS 7/OPMC client can be found in Catalog ST PCS 7 in the Section "SIMATIC Industrial Workstations V7.0".
Siemens ST PCS 7.2 · October 2009
5/5
5
© Siemens AG 2009
OpenPMC migration PCS 7/OPMC Operator System
■ Ordering data
5
Order No.
PCS 7/OPMC OS Single Station Pack V7.0 250 POs, incl. 512 archive tags two languages (English, Italian), executes with Windows XP Professional, Single License for 1 installation Electronic documentation on CD "PCS 7/OPMC Options Version 7.0" and on PCS 7 Toolset DVD Type of delivery: License key disk, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005, incl. EULA and supplementary CDs/DVDs (e.g. Microsoft service packs and tools); CD "PCS 7/OPMC Options Version 7.0"
6EQ2 008-2AA07-3BA0
PCS 7/OPMC OS Server Pack V7.0 250 POs, incl. 512 archive tags two languages (English, Italian), executes with Windows Server 2003, Single License for 1 installation Electronic documentation on CD "PCS 7/OPMC Options Version 7.0" and on PCS 7 Toolset DVD Type of delivery: License key disk, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005, incl. EULA and supplementary CDs/DVDs (e.g. Microsoft service packs and tools); CD "PCS 7/OPMC Options Version 7.0"
6EQ2 008-2HA07-3BA0
PCS 7/OPMC OS Redundant Server Pack V7.0 250 POs, incl. 512 archive tags 2 languages (English, Italian), executes with Windows Server 2003, single license for 2 installations, incl. WinCC/Redundancy and RS 232 connection cable, 10 m Electronic documentation on CD "PCS 7/OPMC Options Version 7.0" and on PCS 7 Toolset DVD Type of delivery: 2 license key disks, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005, incl. EULA and supplementary CDs/DVDs (e.g. Microsoft service packs and tools); CD "PCS 7/OPMC Options Version 7.0"; RS 232 connection cable, 10 m
6EQ2 008-2GA07-3BA0
5/6
■ Ordering data
Order No.
SIMATIC PCS 7 OS Software Client V7.0 5 languages (German, English, French, Italian, Spanish), executes with Windows XP Professional, floating license for 1 user Type of delivery: License key disk, emergency key disk, certificate of license, terms and conditions; PCS 7 V7.0 toolset DVDs, Microsoft SQL Server 2005 including EULA and supplementary CDs/DVDs (e.g. Microsoft service packs and tools) (see Catalog ST PCS 7, Section "OS Software V7.0")
6ES7 658-2CX07-0YA5
SIMATIC IT Historian V6.1 SP1 OPC Server Required for the online connection between SIMATIC PCS 7 Single Station/Server/redundant Server and the OpenPMC controller
6BQ3 074-2AA03-0CA0
Note: SIMATIC IT Historian V6.1 SP1 OPC Server is not included in the PCS 7/OPMC software packages.
Siemens ST PCS 7.2 · October 2009
■
© Siemens AG 2009
Bailey INFI 90/NET 90 migration
6
6/2
Introduction
6/4
PCS 7/90 OS Engineering Station
6/6
PCS 7/90 Operator System
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Bailey INFI 90/NET 90 migration Introduction
■ Overview Engineering system
PCS 7 OS clients
PCS 7/90 OS server
PCS 7/90 OS server (dual-channel)
Bailey Engineering Station
RS 232 or SCSI
CIU
CIU
PCS 7 OS server
RS 232 or SCSI
CIU
Industrial Ethernet (single/redundant)
Computer Interface Unit (CIU)
AS 414FH/ AS 417FH
ET 200M PCU PCU Bailey Plant Loop/ INFI-NET
PCU PCU Bailey Plant Loop/ INFI-NET
ET 200M
AS 414 / AS 416 / AS 417
ET 200M
DP/PA link
ET 200M
6 PCU
Process Control Unit (PCU)
Field devices PCU
PROFIBUS
Configuration example of migration of Bailey INFI 90/NET 90 systems
Many of the process control systems installed worldwide, including the Bailey INFI 90, are approaching the end of their lifecycle. As individual components are now obsolete or no longer repairable, there is an urgent need to modernize these systems. As the hardware, user software and know-how of the operating and maintenance personnel represents enormous value, a gradual migration is often preferred to a complete "rip-out and replace" procedure. The migration strategy developed by Siemens on the basis of the innovative SIMATIC PCS 7 process control system supports many different types of migration scenarios, thus minimizing the investment requirements for an individual automation project. The functionality and performance of an existing system can be significantly increased by modernizing with a SIMATIC PCS 7 operator station. The controller and the subordinate I/O level are retained. At the same time, it is also possible to use SIMATIC PCS 7 AS 41x controllers and SIMATIC process I/Os for plant expansions. Using its universal migration technology "Data Base Automation" (DBA), Siemens is not only able to migrate its own process control systems, but is additionally able to offer matching migration solutions for systems from other vendors, e.g. for systems from ABB or Bailey.
6/2
Siemens ST PCS 7.2 · October 2009
When migrating Bailey INFI 90/NET 90 systems with SIMATIC PCS 7 V7.0, existing Bailey consoles are replaced by operator systems (single stations or client/server systems) based on SIMATIC PCS 7 V7.0. Existing Bailey controller configurations remain unchanged. The OS Single Stations and the OS Servers of such PCS 7/90 operator systems can be operated in redundant or individual mode. The Bailey Plant Loop/INFI-NET is connected in each case to a PCS 7/90 Operator Station (Single Station/Server) via a Computer Interface Unit (CIU) with serial RS 232 or SCSI interface. The Data Base Automation (DBA) software is used when engineering the PCS 7/90 OS stations. The data source for DBA is the Bailey Engineering Workstation with Composer or WinTools.
© Siemens AG 2009
Bailey INFI 90/NET 90 migration Introduction
■ Design The following migration products are available for migration of Bailey INFI 90/NET 90 systems with SIMATIC PCS 7 V7.0: • PCS 7/90 OS Engineering Pack V7.0 (unlimited POs) for an exclusive engineering station, consisting of - SIMATIC PCS 7 OS Engineering V7.0 (incl. Service Pack) - DBA for Bailey and third-party controllers - Library with icons, faceplates and diagnostics displays • PCS 7/90 OS Engineering Pack V7.0 (250 POs) for an combined engineering/operator station, consisting of - SIMATIC PCS 7 OS Engineering V7.0 (incl. Service Pack) - DBA for Bailey and third-party controllers - Library with icons, faceplates and diagnostics displays - RoviSys OPC90 Server (unlimited Bailey tags) • PCS 7/90 OS Server Pack V7.0 (250 POs) for a single server, consisting of - SIMATIC PCS 7 OS Software Server V7.0 (incl. Service Pack) - Library with icons, faceplates and diagnostics displays - RoviSys OPC90 Server (unlimited Bailey tags) • PCS 7/90 OS Redundant Server Pack V7.0 (250 POs) for a redundant pair of servers, consisting of - SIMATIC PCS 7 Server Redundancy V7.0 (incl. Service Pack) with WinCC/Redundancy and 2 server licenses - Library with icons, faceplates and diagnostics displays - 2x RoviSys OPC90 Server (unlimited Bailey tags) • PCS 7/90 OS Single Station Pack V7.0 (250 POs) for a single station, consisting of - SIMATIC PCS 7 OS Software Single Station V7.0 (incl. Service Pack) - Library with icons, faceplates and diagnostics displays - RoviSys OPC90 Server (unlimited Bailey tags) The PCS 7/90 OS Client V7.0 is identical with the SIMATIC PCS 7 OS Client V7.0. Software upgrade If you have already modernized the Bailey INFI 90/NET 90 system with PCS 7/90 OS migration products V6.1, you can upgrade the PCS 7/90 engineering and operator stations to V7.0 using the following upgrade software: • PCS 7/90 OS Upgrade Package Engineering from V6.1 to V7.0 to upgrade a PCS 7/90 OS engineering station from V6.1 to V7.0 • PCS 7/90 OS Upgrade Package Runtime from V6.1 to V7.0 to upgrade a PCS 7/90 OS single station, a PCS 7/90 OS server or a redundant pair of PCS 7/90 OS servers from V6.1 to V7.0 • PCS 7 OS Client/SFC Visualization Upgrade Package from V6.0/6.1 to V7.0 to upgrade a PCS 7/90 OS client from V6.1 to V7.0 Multi-client and dual-channel functionality Data from different systems can be displayed on the OS clients in a process picture: • Data from Bailey controllers (PCUs) on the Bailey Plant Loop/INFI-NET • Data from the SIMATIC PCS 7 automation systems on the SIMATIC PCS 7 plant bus Industrial Ethernet.
Supported system components The PCS 7/90 OS migration products support the following Bailey system components: Bailey consoles
Computer Interface Units (CIU)
OIU PCView MCS and MCS PLUS OIS Series 1x OIS Series 2x OIS Series 3x OIS Series 40/41/42 OIS Series 43/45 Process Portal A or B Conductor NT
NSPM01 IMSPM01 IMCPM02 IMCPM03 NCIU01 NCIU02 NCIU03 NCIU04 NCIC01 INPCI01 INPCI02 IIMCP01 IIMCP02 INICI01 INICI12 INICI03
Note: PCS 7/90 OS V7.0 has been tested and released with representative configurations on the basis of Network 90 controllers (NMPC01, NMFC01NMFC05) and INFI-NET 90 controllers (IMMFP01). If you are using other types of controller we recommend that you seek support from the Technical Consulting department of Customer Support. You will find information about the range of services of Customer Support and details of regional contacts in the appendix to this catalog.
■ Options Conversion of existing graphics from Bailey consoles The modern DBA technology of Siemens permits fast and secure implementation of your user software. Your investment in the configuration of the existing system is therefore safeguarded. It goes without saying that we also offer this conversion as a service. But you can call upon the services of our experienced migration specialists not only for this reason, but also when generating new graphics. We would be pleased to provide you with an individual quotation. For quotations and additional information, please contact your regional Siemens representative.
■ More information You can find detailed information, ordering data and technical specifications on individual migration products in the following sections "PCS 7/90 Engineering Station" and "PCS 7/90 Operator System". Additional information is available in the Internet under: www.siemens.com/simatic-pcs7/migration
The multi-client architecture of the operator systems enables a client to retrieve data from different servers. With smaller systems it is possible to use a PCS 7/90 OS server with dual-channel functionality. This implements the communication with the Bailey controllers and the SIMATIC PCS 7 automation systems via two separate channels DLLs.
Siemens ST PCS 7.2 · October 2009
6/3
6
© Siemens AG 2009
Bailey INFI 90/NET 90 migration PCS 7/90 OS Engineering Station
■ Design
6
PCS 7/90 OS Engineering Pack V7.0
PCS 7/90 OS DBA V7.0
This software package is required for OS engineering and OS interfacing of the APACS+/QUADLOG controller. Depending on the application area, you can choose between two product versions whose licensing differs as follows: • PCS 7/90 OS engineering pack V7.0 (unlimited POs) for an exclusive engineering station with unlimited OS engineering license; in this version the use as an operator station is restricted to a 2-hour test mode. Continuous use in productive operation is not possible. • PCS 7/90 OS engineering pack V7.0 (250 POs), for a combined engineering/operator station; in addition to an OS engineering license for 250 POs, this version also includes an OS runtime license for 250 POs. The number of process objects (PO) is expandable with SIMATIC PCS 7 PowerPacks V7.0 from Catalog ST PCS 7, section "ES Software V7.0".
This OS Engineering package contains the Data Base Automation software as well as Bailey-specific OS icons, OS faceplates and OS diagnostics displays.
Both product versions contain the components listed below: • SIMATIC PCS 7 engineering software for OS V7.0 (including SP) with the licenses described above in accordance with Catalog ST PCS 7, Section "ES Software V7.0" • PCS 7/90 OS DBA Database Engineering Package for the migration of user data. • PCS 7/90 OS library with OS function block icons and OS faceplates • OPC Engineering plug-in for interfacing third-party controllers (e.g. Allen-Bradley)
The PCS 7/90 OS icons, faceplates and diagnostics displays created in line with the SIMATIC PCS 7 standard take into account the special properties of the Bailey controllers (PCUs).
The RoviSys OPC90 Server (unlimited Bailey tags) is only included in the PCS 7/90 OS Engineering Pack V7.0 (250 PO) for a combined engineering/operator station. Further SIMATIC PCS 7 engineering software for a PCS 7/90 engineering station can be ordered using Catalog ST PCS 7, Section "ES software V7.0". Appropriate basic hardware for a PCS 7/90 OS engineering station can be found in the section "SIMATIC PCS 7 Industrial Workstations V7.0" of Catalog ST PCS 7.
The Data Base Automation software automatically generates the OS database with the display hierarchy, required tags, alarm messages and alarm priorities as well as the specific block icons and faceplates. The display hierarchy is the basis for navigation between the process pictures, for alarm management, and for implementing security measures. PCS 7/90 OS DBA automatically places the type-specific block icons, e.g. controller or analog input(AI), in the generated process pictures. These icons are linked to the corresponding function blocks and faceplates through the database. Manual configuration is mainly limited to the design and positioning of the static graphic elements, e.g. tubes or tanks.
The following functions are supported: Name
Description
Bailey block No.
Process I/O Functions ANALOG
Analog exception report tag
FC 30, 70, 158
DAANG
Data acquisition analog tag
FC 177
DADIG
Data acquisition digital tag
FC 211, 224, 225
DD
Device driver tag
FC 123
DIGITAL
Digital exception report tag
FC 45, 224, 225
MSDD
Multi-state device driver tag
FC 129
Process Control Functions RCM
Remote control memory tag
FC 62
RMCB
Remote motor control tag
FC 136
RMSC
Remote manual set constant tag
FC 68
Diagnostics STATION
Control station exception report tag
FC 21, 22, 23, 80
N90STA
INFI 90 status tag; reads status and problem reports from modules
--
CIU Device
CIU status
--
Display Functions TEXT
Text selector tag
FC 151
TEXTSTR
Text string tag
FC 194
Engineering interface for third-party controllers DBA enables the user to import a CSV file in order to define AS objects. This simplifies the integration of data coming from thirdparty OPC servers, e.g. tags for a third-party controller. This permits seamless integration of these data into the process control system.
6/4
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Bailey INFI 90/NET 90 migration PCS 7/90 OS Engineering Station
■ Ordering data
Order No.
Software for exclusive engineering station with unlimited OS engineering license (not suitable for productive operation as an operator station; 2-hour OS test mode possible) PCS 7/90 OS engineering pack V7.0 (unlimited POs) without RoviSys OPC90 Server 1 language (English), executes with Windows XP Professional, floating license for 1 user Electronic documentation on CD "PCS 7/90 Options V7.0" and PCS 7 Toolset DVD Type of delivery: • License key memory stick, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/90 Options V7.0"
6EQ2 003-1BD07-3BA5
■ Ordering data
Order No.
Software upgrade PCS 7/90 OS engineering upgrade package from V6.1 to V7.0 1 language (English), executes with Windows XP Professional, floating license for 1 user Type of delivery: • 2 license key memory sticks, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/90 Options V7.0" • RoviSys OPC90 Server upgrade package
6EQ2 003-1XX07-3BE5
Software for combined engineering/operator station with 250 OS engineering and runtime POs (can be used as operator station for productive operation) PCS 7/90 OS engineering pack V7.0 (250 POs) including RoviSys OPC90 Server (unlimited Bailey tags) 1 language (English), executes with Windows XP Professional, floating license for 1 user Electronic documentation on CD "PCS 7/90 Options V7.0" and PCS 7 Toolset DVD Type of delivery: • License key memory stick, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/90 Options V7.0" • RoviSys unlimited OPC90 server package
6EQ2 003-1BA07-3BA5
6
Siemens ST PCS 7.2 · October 2009
6/5
© Siemens AG 2009
Bailey INFI 90/NET 90 migration PCS 7/90 Operator System
■ Overview The software components offered for migration of existing Bailey INFI 90/NET 90 systems are tailored to the architecture of the SIMATIC PCS 7 operator system. They support single-user systems (Single Stations) as well as multi-user systems with up to 12 servers/redundant pairs of servers and up to 32 clients.
Example faceplate with adjustable parameters
■ Design The following software components are required depending on the configuration of a PCS 7/90 operator system as single station or client/server combination (single or redundant server): Required software
SIMATIC PCS 7 architecture OS Single Station
PCS 7/90 OS Single Station Pack V7.0
6
PCS 7/90 OS Server Pack V7.0
Client/ server (non-redundant server)
● ● ●
PCS 7/90 OS Redundant Server Pack V7.0 PCS 7 OS Software Client V7.0 See Catalog ST PCS 7, section "OS Software V7.0"
Client/ server (redundant server)
●
●
PowerPacks as well as further software for PCS 7/90 operator systems can be ordered from the Catalog ST PCS 7, in the section "OS Software V7.0". Appropriate basic hardware for a PCS 7/90 operator station as a single station, server or client version can be found in Catalog ST PCS 7 in the section "SIMATIC PCS 7 Industrial Workstations V7.0". Note: Please note with redundant PCS 7/90 OS Servers or PCS 7/90 OS Single Stations, that the following functions each occupy a COM port in each station: • Optimization of the internal communication over RS 232 connection between the two redundant stations • RS 232 interfacing of the Bailey Plant Loop/INFI-NET per Computer Interface Unit (CIU). If the basic hardware of the redundant stations does not include two COM ports, you have the following alternatives: • Use of an additional interface expansion card • Optimization of the internal redundancy communication via a separate Ethernet connection instead of the serial RS 232 connection (for details, see "SIMATIC PCS 7 V7.0 Fault Tolerant Process Control Systems" manual)
6/6
Siemens ST PCS 7.2 · October 2009
PCS 7/90 OS Software The PCS 7/90 OS Software is used for the OS interfacing of Bailey controllers (PCUs) using an engineering system (PCS 7/90 ES) as well as for operation and monitoring of the PCUs (Process Control Units) using an operator system (PCS 7/90 OS) based on SIMATIC PCS 7. ES/OS communication with the Bailey controllers is carried out via OPC (OLE for Process Control). The PCS 7/90 OS Software physically supports communication via RS 232 or SCSI. It contains the following components: • RoviSys OPC server, configured with DBA • Library with block icons, faceplates and diagnostics displays, for reading and writing the available Bailey function block information
© Siemens AG 2009
Bailey INFI 90/NET 90 migration PCS 7/90 Operator System
■ Ordering data
Order No.
PCS 7/90 OS single station pack V7.0 (PO 250) Includes RoviSys OPC90 Server 1 language (English), executes with Windows XP Professional, Single License for 1 installation Electronic documentation on CD "PCS 7/90 Options V7.0" and PCS 7 Toolset DVD Type of delivery: • License key memory stick, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/90 Options V7.0" • RoviSys unlimited OPC90 server package
6EQ2 003-2AA07-3BA0
PCS 7/90 OS server pack V7.0 (PO 250) Includes RoviSys OPC90 Server 1 language (English), executes with Windows Server 2003, single license for 1 installation Electronic documentation on CD "PCS 7/90 Options V7.0" and PCS 7 Toolset DVD Type of delivery: • License key memory stick, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/90 Options V7.0" • RoviSys unlimited OPC90 server package
6EQ2 003-2HA07-3BA0
■ Ordering data
Order No.
PCS 7/90 OS redundant server pack V7.0 (250 POs) Includes 2 x RoviSys OPC90 Servers 1 language (English), executes with Windows Server 2003, single license for 2 installations includes WinCC/Redundancy and RS 232 connecting cable, 10 m Electronic documentation on CD "PCS 7/90 Options V7.0" and PCS 7 Toolset DVD Type of delivery: • License key memory stick with 2 licenses, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/90 Options V7.0" • 2 RoviSys unlimited OPC90 server packages • RS 232 connecting cable, 10 m
6EQ2 003-2GA07-3BA0
SIMATIC PCS 7 OS Software Client V7.0 6 languages (German, English, French, Italian, Spanish, Chinese), executes with Windows XP Professional, floating license for 1 user (see Catalog ST PCS 7, section "OS Software V7.0")
6ES7 658-2CX07-0YA5
6
Software upgrade PCS 7/90 OS Runtime upgrade package from V6.1 to V7.0 for OS Single Station or OS Server 1 language (English), executes with Windows XP Professional/Server 2003, Single License for 1 installation Type of delivery: • License key memory stick, certificate of license including terms and conditions • Toolset DVDs and product information PCS 7 V7.0 (incl. SP), Microsoft SQL Server 2005 including EULA, as well as supplementary CDs/DVDs (e.g. Microsoft service packs and tools) • CD "PCS 7/90 Options V7.0" • RoviSys OPC90 Server upgrade package
6EQ2 003-2XX07-3BE0
SIMATIC PCS 7 OS client/ SFC visualization upgrade package V6.0/V6.1 to V7.0 5 languages (German, English, French, Italian, Spanish), executes with Windows XP Professional, floating license for 1 user (see Catalog ST PCS 7, section "Upgrades from SIMATIC PCS 7 V6.x to V7.0")
6ES7 652-5CX07-0YE5
■ Siemens ST PCS 7.2 · October 2009
6/7
© Siemens AG 2009
Bailey INFI 90/NET 90 migration
6
6/8
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Honeywell TDC migration 7/2
7 Honeywell TDC migration
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Honeywell TDC migration Honeywell TDC migration
■ Overview
■ Design
Many of the globally installed process control systems, for example the Honeywell TDC 3000/2000, have reached the end of their lifecycle. In the case of process control systems whose automation systems (controllers) and operation and monitoring systems are obsolete, the complete rip-out and replace procedure with retention of the field cabling is the best choice for future-oriented automation. The Siemens migration solution for the TDC 3000 based on the SIMATIC PCS 7 process control system is characterized by the fact that the switchover and restart of the process cell is possible within a very short time. With careful preparation, production can usually restart after just one day.
16-channel analog input module FTA (Field Termination Assemblies)
7
8-channel analog output module FTA
7/2
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Honeywell TDC migration Honeywell TDC migration Siemens FTA modules and connecting cables The table below shows the available Siemens FTA modules and connecting cables for the migration of the Honeywell TDC 3000 system with SIMATIC PCS 7. Module
Honeywell IOP
Honeywell FTA
Siemens FTA
Connection cable
SIMATIC PCS 7 ET 200M module
16-channel analog input module
PAIH02 PSTX02
MU-TAIH01 MU-TAIH02 MU-TAIH03
6EQ2 012-1BA10-3BA0
6EQ2 012-2BE30-0BA0 (2 cables required)
6ES7 331-7NF00-0AB0 (2 modules required)
8-channel analog output module
PAOX02
MU-TAOX01 MU-TAOX02 MU-TAOY221) MU-TAOY231)
6EQ2 012-1BB10-2BA0
6EQ2 012-2BE30-0BA0
6ES7332-5HF00-0AB0
16-channel analog output PAOY22 module
MU-TAOY221) MU-TAOY231)
6EQ2 012-1BB10-2BA0 (2 FTA required)
6EQ2 012-2BE30-0BA0 (2 cables required)
6ES7332-5HF00-0AB0 (2 modules required)
32-channel 24 V DC digi- PDIX02 tal input module
MU-TDID12
6EQ2 012-1BC11-4BA0
6EQ2 012-2BE30-0BA0
6ES7321-1BL00-0AA0
32-channel 120 V AC digital input module
MU-TDIA12
6EQ2 012-1BC21-4BA0
6EQ2 012-2BE30-0BA0
6ES7321-1BL00-0AA0
16-channel 24 V DC digi- PDOX02 tal output module PDOY22
MU-TDOD112) MU-TDOD122) MU-TDOD132) MU-TDOD142)
6EQ2 012-1BD11-3BA0
6EQ2 012-2BD30-0BA0
6ES7322-1BH01-0AA0
16-channel 120 V AC digital output module
PDOX02
MU-TDOA11 MU-TDOA12 MU-TDOA13
6EQ2 012-1BD21-3BA03)
6EQ2 012-2BD30-0BA0
6ES7322-1BH01-0AA0
16-channel 120 V AC relay output module
PDOX02 PDOY22
MU-TDOR12 MU-TDOY23
6EQ2 012-1BD32-3BA03)
6EQ2 012-2BD30-0BA0
6ES7322-1BH01-0AA0
1)
Only non-redundant
2)
Fuse rating 5 A
3)
Only 120 V AC
PDIX02
■ Mode of operation Siemens FTA modules
Porting the user software
The Siemens migration solution leaves both the field cabling and the original Honeywell FTA (field termination assemblies) cabinet where they are. The FTA modules mounted in this FTA cabinet, however, are replaced by new Siemens FTA modules. This eliminates the enormous amount of time and money required for rewiring the field devices.
Before the modern SIMATIC PCS 7 process control system with its powerful S7-400 automation systems and flexible Windowsbased operator stations can take over the process management, the existing user software must first be ported. The conversion of the control programs and screen displays from Honeywell TDC 3000 to SIMATIC PCS 7 is offered as a service by Siemens. For further information and offers, please contact your regional SIMATIC PCS 7 sales partner.
Siemens offers replacement modules and connection cables for a wide range of Honeywell FTA modules. The Siemens FTA modules have the same dimensions as their Honeywell counterparts. The terminal elements and the dimensions for the fixing holes are also identical. The wired connecting terminals are simply pulled out of the existing Honeywell FTA modules and inserted in the new Siemens FTA modules. Their connecting cables are routed to the I/O modules of SIMATIC PCS 7 that are mounted in a SIMATIC PCS 7 cabinet together with the SIMATIC PCS 7 automation system. This SIMATIC PCS 7 cabinet replaces the corresponding original control cabinet with the Honeywell controller and the I/O modules.
Siemens ST PCS 7.2 · October 2009
7/3
7
© Siemens AG 2009
Honeywell TDC migration Honeywell TDC migration
■ Ordering data
7
■ Ordering data
Order No. A)
Analog input module FTA for ET 200M Replaces Honeywell TDC 3000 MU-TAIH01, MU-TAIH02, MU-TAIH03 16 analog input channels for analog input module 6ES7 3317NF00-0AB0 (requires 2 modules)
6EQ2 012-1BA10-3BA0
Analog output module FTA for ET 200M Replaces Honeywell TDC 3000 MU-TAOX01, MU-TAOX02, MU-TAOY22, MU-TAOY23 8 analog outputs for analog output module 6ES7 332-5HF000AB0
6EQ2 012-1BB10-2BA0
Digital input module FTA for ET 200M Replaces Honeywell TDC 3000 MU-TDID12 32 digital input channels 24 V DC for digital input module 6ES7 3211BL00-0AA0
6EQ2 012-1BC11-4BA0
Digital input module FTA for ET 200M Replaces Honeywell TDC 3000 MU-TDIA12 32 digital input channels 120 V AC for digital input module 6ES7 321-1BL00-0AA0
6EQ2 012-1BC21-4BA0
A)
Digital output module FTA for ET 200M Replaces Honeywell TDC 3000 MU-TDOD11, MU-TDOD12, MU-TDOD13, MU-TDOD14 16 digital outputs 24 V DC for digital output module 6ES7 3221BH01-0AA0
6EQ2 012-1BD11-3BA0
A)
Digital output module FTA for ET 200M Replaces Honeywell TDC 3000 MU-TDOA11, MU-TDOA12, MU-TDOA13 16 digital outputs 120 V AC for digital output module 6ES7 3221BH01-0AA0
6EQ2 012-1BD21-3BA0
A)
Digital output module FTA for ET 200M replaces Honeywell TDC 3000 MU-TDOR12, MU-TDOY23 16 relay outputs 120 V AC / 5 A for digital output module 6ES7 322-1BH01-0AA0
6EQ2 012-1BD32-3BA0
A)
7/4
A)
Order No.
Accessories Connection cable for analog input/output module and digital input module FTA, 8 m with 50-pin Sub-D connector and 40-pin Siemens front connector 6ES7 392-1AM00-0AA0
6EQ2 012-2BE30-0BA0
A)
Connection cable for digital output module FTA, 8 m with 50-pin Sub-D connector and 20-pin Siemens front connector 6ES7 392-1AJ00-0AA0
6EQ2 012-2BD30-0BA0
A)
A) Subject to export regulations: AL: N, ECCN: EAR99H
■ More information A)
For further information, offers and consultations, please contact your regional SIMATIC PCS 7 sales partner.
■
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
ABB Contronic P migration 8/2
8 ABB Contronic P migration
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
ABB Contronic P migration ABB Contronic P migration
■ Overview
■ Benefits
Siemens already has a wealth of experience in the migration of Contronic P from a host of projects. Because of the very short remaining time for which the manufacturer will still keep supplies of components, a complete replacement has emerged as the ideal solution for the Contronic P-migration. The particular features of the Siemens migration solution for Contronic P are: • Software-supported conversion of user software • Changeover during operation • Changeover concepts for the field instrumentation tailored to different customer requirements Thanks to the database-supported conversion of the engineering data, errors are avoided and the engineering times significantly reduced in comparison with a regeneration. Optimized control parameters are converted to SIMATIC PCS 7 with largely the same effect. This ensures that the results of the process optimizations, some of which have been established over many years, can continue to be used in the long term.
The added value of the system replacement is obtained mainly by: • More effective engineering • Easier operation through more user-friendly process control (alarm hiding, fast navigation, etc.) • Higher performance and quality, optimizable with Advanced Process Control • Optimization of maintenance and service through statusbased asset management • Support of the business processes by interfacing of IT applications, e.g. SIMATIC IT • Comprehensive IT security by means of the PCS 7 Security Concept (high relevance due to increasing Internet usage and networking with office applications) • Assured future for the automation of the production plant
The application is not converted block by block, but functionally, i.e. process tag by process tag. In doing so, a valve or motor controller is mapped in Contronic P by a corresponding typical in SIMATIC PCS 7. The corresponding SIMATIC PCS 7 application is therefore easy to read and to modify.
■ Design Contronic P Option: Matching using hardware planning tools, e.g. E-Plan
Memory dump of user software
8 SIMATIC PCS 7 Manual conversion Interlocking, STEP programs (SFC)
Engineering System
Database Clarification with the customer SIMATIC PCS 7 Import/export wizard Software-based conversion Motor, valve, PID controller Process tags list
8/2
Siemens ST PCS 7.2 · October 2009
Typicals library Measurement, PID controller, motor, valve, ...
© Siemens AG 2009
ABB Contronic P migration ABB Contronic P migration The migration specialists at Siemens possess extensive plant knowledge in various sectors of industry as well as many years of experience in engineering, service and commissioning. First, they analyze the data of your plant and produce a clear and detailed quotation for the conversion to a modern automation plant based on SIMATIC PCS 7 that is easy to maintain and documented in detail. In order that everything is in the right place at the right time and to ensure a smooth changeover, the migration specialists work with you in the preliminary stages to draw up a realistic detailed plan for the entire sequence of the project. Apart from the expense of purchasing new hardware and software and also porting the user software, one key cost factor in a Contronic P-Migration is the downtime. This is determined by the concept for the changeover of the I/O signals (in the Contronic P-cabinet or on the sub-distribution board) as well as by the quality of the technological implementation of the user software.
The software-based migration of Contronic P to SIMATIC PCS 7 is carried out in clear, individually tested and verifiable steps. • Export of the Contronic P application by means of a "memory dump" of the user software, and importing into a database • Acceptance of the existing typicals von Contronic P, e.g. controller, valve or measured value recording, based on standard function blocks of SIMATIC PCS 7 • Conversion of the existing user software (up to 80% automatic) This indicates where the automation reaches its limits and human intervention is required. All conversion steps implemented are documented in detail.
■ More information For preliminary discussions, elaboration of concepts, and quotations, please contact your regional SIMATIC PCS 7 representative.
■
Although the switchover directly in the Contronic P-cabinet saves space for additional system cabinets, it requires a short plant standstill. When making the switchover on the sub-distribution board, the signals of one process tag can be rewired together while the plant is operating. Analytical software determines which signals belong together and indicates any temporary duplicate wiring that is necessary. This concept, however, requires additional hardware and correspondingly more space.
8
Siemens ST PCS 7.2 · October 2009
8/3
© Siemens AG 2009
ABB Contronic P migration
8
8/4
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Invensys Triconex connection 9/2
9
Invensys Triconex connection
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Invensys Triconex connection Invensys Triconex connection
■ Overview OS clients
SIMATIC PCS 7 OS server Industrial Ethernet
SIMATIC PCS 7 fault tolerant automation systems Tristation Gateways CM104_TSAA
Tricon-controller
Tricon-controller
Integration of the safety-oriented Tricon and Trident controllers into SIMATIC PCS 7 via CM104_TSAA gateway
In the past it was customary to operate safety-oriented controllers separately from the process control system. Consequently, safety controllers are not always included directly in the modernization of the process control system.
9
A Siemens solution developed for the migration with SIMATIC PCS 7 enables the Triconex safety controllers Tricon and Trident from Invensys to be integrated into the process control system when modernizing existing plants.
■ Design The Tricon and Trident controllers are connected via the CM104_TSAA gateway, the TSAA protocol of Triconex being used for the communication. The CM104_TSAA Gateway operated on the SIMATIC PCS 7 Industrial Ethernet plant bus is connected by means of an Ethernet interface to the Triconex safety controller. Compliant with the redundant system architecture, two gateways are always used in parallel.
9/2
Siemens ST PCS 7.2 · October 2009
■ Function The CM104_TSAA gateway manages the data exchange between the SIMATIC PCS 7 automation systems and the Tricon/Trident controllers. The SIMATIC PCS 7 automation systems communicate with the gateway via the function blocks provided in a separate CFC library, using the S7 system function BSEND/BRECV for this purpose. If defined errors occur, integrated diagnostics functions trigger corresponding alarm messages in the SIMATIC PCS 7 operator system. The integration of event messages in the correct chronological order into the message recording and logging of the SIMATIC PCS 7 operator systems can be implemented on a project-specific basis.
© Siemens AG 2009
Invensys Triconex connection Invensys Triconex connection
■ Configuration
■ More information As a large number of different Triconex components must be considered when integrating Triconex safety controllers into SIMATIC PCS 7, the CM104_TSAA gateway with the associated function block library is offered only as part of a project-specific service. Please direct any inquiries regarding the preparation of an offer to: Siemens AG Industry Sector Industry Solutions Division, Karlsruhe Phone: +49 721595-7024 E-mail:
[email protected] You can obtain further information on request from your regional Siemens representative or from the Internet at: www.siemens.com/pcs7_triconex
■
Triconex communications blocks in the CFC
The basis for configuration of the Triconex communication is a CFC library with specially generated function blocks. Individual, tag-oriented read and write blocks facilitate the positioning of the communications blocks within a technological function block. The read and write function blocks offered for various data types conform to the SIMATIC PCS 7 driver concept. Triconex tags are addressed via Triconex Alias directly to the SIMATIC PCS 7 function blocks. This simplifies the configuration with the SIMATIC PCS 7 import/export wizards as well as the commissioning. Using the integrated simulation functions, the SIMATIC PCS 7 configuration can also be tested without the safety-related controller. The Triconex application requires only that the access by TSAA protocol is enabled and a "sign of life" is implemented.
9
Siemens ST PCS 7.2 · October 2009
9/3
© Siemens AG 2009
Invensys Triconex connection
9
9/4
Siemens ST PCS 7.2 · October 2009
10
© Siemens AG 2009
Integration of third-party controllers using PCS 7/OPEN OS 10/2
Introduction
10/3 10/3
Engineering PCS 7/OPEN OS Engineering Station
10/6 10/6
Operator control and monitoring PCS 7/OPEN OS Operator System
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Integration of third-party controllers using PCS 7/OPEN OS Introduction
■ Overview Engineering System
SIMATIC PCS 7 OS clients
Controller Engineering
PCS 7/OPEN OS Server
SIMATIC PCS 7 OS server
PCS 7/OPEN OS Server (dual channel)
Industrial Ethernet (single/redundant)
Ethernet
AS 414FH/ AS 417FH
I/O
ET 200M
Third-party controller
ET 200M
Third-party controller
AS 414 / AS 416 / AS 417
ET 200M
DP/PA link
ET 200M
PROFIBUS
Field devices
Configuration example for the SIMATIC PCS 7 integration of third-party controllers with PCS 7/OPEN OS
Siemens offers a host of OS migration products that enable controllers that do not belong to the range of SIMATIC PCS 7 system components to be integrated into the process management with the SIMATIC PCS 7 operator system. This applies to controllers of Siemens and third-party control systems such as APACS+/QUADLOG, Bailey INFI 90/NET 90, OpenPMC, TELEPERM M or SIMATIC PCS/TISTAR.
The core of PCS 7/OPEN OS is based on the database automation software (DBA) familiar from other OS products and essentially comprises the following components: • SIMATIC PCS 7 OS engineering and runtime software • PCS 7/OPEN OS DBA data base automation software • PCS 7/OPEN OS runtime software option
Supplementary to this, PCS 7/OPEN OS gives you the option of using the SIMATIC PCS 7 operator system also for the operation and monitoring of controllers for which no specific Siemens OS migration products are available.
The functionality supplied enables the project engineer to integrated the existing third-party controllers with additional engineering services effectively into the process control with the SIMATIC PCS 7 operator system.
The prerequisite for the use of PCS 7/OPEN OS is that an OPC server exists for the respective controller type. PCS 7/OPEN OS supports the data exchange with the controllers via OPC DA and OPC A&E.
The additional OS engineering services include: • Creation of the type definitions and type instances in the context of the DBA engineering • Creation of the OS function block icons and OS faceplates according to the specific properties of the third-party controllers
10
The existing engineering system continues to be used for changing the existing controller configuration.
10/2
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Integration of third-party controllers using PCS 7/OPEN OS Engineering PCS 7/OPEN OS Engineering Station
■ Design SIMATIC PCS 7 engineering system with Windows XP Professional / Windows Server 2003 operating system Field of application
Classic, exclusively engineering station
Can be used as operator station for productive operation Version
Combined engineering/operator station for small applications
●
– Project server
Project client
Single station
Single station
BCE
BCE
BCE
BCE
IE
IE
IE
IE
SIMATIC PCS 7 Industrial Workstation including operating system BCE communication for up to SIMATIC PCS 7 ES/OS BCE WXP 8 automation systems (single SIMATIC PCS 7 OS Server BCE SRV03 stations only) Industrial Ethernet (IE) communication
●
●
●
● ●
SIMATIC PCS 7 ES/OS IE WXP
●
●
●
SIMATIC PCS 7 OS Server IE SRV03
PCS 7/OPEN OS engineering packages, alternatives • For the integration of third-party controllers in a new plant PCS 7/OPEN OS Engineering Pack V7.1 (incl. SIMATIC PCS 7 V7.1 software)
Without OS Runtime license for productive operation (2-hour OS test mode possible)
●
●
●
●
With OS Runtime license for productive operation
• For the integration of third-party controllers into an existing plant PCS 7/OPEN OS Engineering Component Option V7.1 (without SIMATIC PCS 7 V7.1 software)
PCS 7/OPEN OS Engineering Pack V7.1 This software package is required for the engineering of the PCS 7/OPEN OS operator stations. Depending on the application area, you can choose between two product versions whose licensing differs as follows: • PCS 7/OPEN OS Engineering Pack V7.1 ( unlimited POs) for an exclusive engineering station with unlimited OS engineering license; in this version the use as an operator station is restricted to a 2-hour test mode. Continuous use in productive operation is not possible. • PCS 7/OPEN OS Engineering Pack V7.1 (250 POs) for a combined engineering/operator station; in addition to an OS engineering license for 250 POs, this version also includes an OS runtime license for 250 POs. The number of process objects (PO) is expandable with SIMATIC PCS 7 Engineering PowerPacks AS/OS V7.1, chapter "Engineering System", section "ES Software".
●
●
●
●
Further SIMATIC PCS 7 engineering software for a PCS 7/OPEN OS engineering station can be ordered using Catalog ST PCS 7, Chapter "Engineering System", Section "ES software". Appropriate basic hardware for a PCS 7/OPEN OS engineering station can be found in the section "SIMATIC PCS 7 Industrial Workstation" of Catalog ST PCS 7. PCS 7/OPEN OS Engineering Component Option V7.1 The PCS 7/OPEN OS engineering component option V7.1 is suitable for integrating third-party controllers into an existing SIMATIC PCS 7 V7.1 process control system. Unlike the PCS 7/OPEN OS Engineering Pack V7.1, it is consequently not equipped with the SIMATIC PCS 7 engineering software for OS V7.1.
Both product versions contain the components listed below: • SIMATIC PCS 7 Engineering Software for OS V7.1 with the licenses described above, according to Catalog ST PCS 7, Chapter "Engineering System", Section "ES software" • PCS 7/OPEN OS DBA Database Engineering Package, comprising DBA control center, type editor, instance editor and runtime expansion platform • Licenses for the loading of the third-party controller engineering data into the DBA, for compiling the DBA configuration into a SIMATIC PCS 7 operator station and for access to the A&E data of the OPC server
10
Siemens ST PCS 7.2 · October 2009
10/3
© Siemens AG 2009
Integration of third-party controllers using PCS 7/OPEN OS Engineering PCS 7/OPEN OS Engineering Station
■ Function A core component for the PCS 7/OPEN OS engineering is the database automation software PCS 7/OPEN OS DBA. It generates the OS data with the plant hierarchy, the alarms and messages from the OPC tags budget of the OPC server connected with the third-party controller. The plant hierarchy is the basis for the hierarchical structure of the process pictures on the SIMATIC PCS 7 operator station and for the alarm management.
List of Block Types with instances and their address
Sources of information (whatever is available)
Correspondence List List of tags for display and operation
Third-PartyDocumentation (Function Block Description)
Third-Party Engineering Data (Function Block oriented)
Identification of the required Function Blocks for Display and Operation
- Microsoft Excel - Third-Party ES
Step 2
Hierarchy Definition
DBA
Block Icon / Faceplate Design
compile CSV file
PCS 7 Standard Faceplates
OPC Items (OPC Browse)
Step 1
The PCS 7/OPEN OS DBA is also used for the configuration of: • Runtime Extension Framework (responsible for the synchronization, persistence of the alarm status information) • SIMATIC PCS 7 message system (alarm logging) • SIMATIC PCS 7 archive system (tag logging)
Native Source Document
import
- Graphics Designer - Faceplate Designer
PCS 7/OS Project
export
Bulk Editing, e.g. with Microsoft Excel
Step 3
Step 4
Step 5
Working sequence for the integration of the third-party controllers into the SIMATIC PCS 7 operator system
Working sequence for the integration of the third-party controllers into the SIMATIC PCS 7 operator system Step 1 First, the information sources suitable for Step 2 must be determined: • Engineering system of the third-party controller • Description of the third-party controllers • Source data of the OPC server Step 2
10
The function blocks and their parameters relevant for the display and operation then have to be identified on the basis of the sources of information determined in Step 1.
Step 3 The type editor from the PCS 7/OPEN OS DBA must then be used to create templates for the function blocks used in the application. The instance editor first creates an instance of each of these templates. This instance can then be exported to Microsoft Excel for the fast preparation of all instances of one type. The instances created in Microsoft Excel can subsequently be reimported into the instance editor. At the same time, function block icons and faceplates are to be created for all new function block types using SIMATIC PCS 7 OS standard tools (Graphics Designer and Faceplate Designer). Step 4 On completion of all instances, the content of the instance editor is to be exported to the DBA database and the plant hierarchy is to be created. This is followed by the compilation and import of the DBA data into the SIMATIC PCS 7 operator system. Step 5 Following the import of the OS data relevant for the third-party controller into the SIMATIC PCS 7 OS project, the sequence of the subsequent configuration is analogous to a SIMATIC PCS 7 standard project.
10/4
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Integration of third-party controllers using PCS 7/OPEN OS Engineering PCS 7/OPEN OS Engineering Station
■ Ordering data
■ Ordering data
Order No.
Software for exclusive engineering station with unlimited OS engineering license (not suitable for productive operation as an operator station; 2-hour OS test mode possible) PCS 7/OPEN OS Engineering Pack V7.1 (unlimited POs) 1 language (English), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Electronic documentation, on CD/DVD Type of delivery: • License key memory stick, certificate of license including terms and conditions • SIMATIC PCS 7 Data Medium Package V7.1 • CD "PCS 7/OPEN OS Option V7.1"
6EQ2 001-1BB17-3BA5
Order No.
PCS 7/OPEN OS Engineering Packages i ncl. SIMATIC PCS 7 V7.1 Software for the integration of third-party controllers into an existing SIMATIC PCS 7 V7.1 architecture
PCS 7/OPEN OS Engineering Packages incl. SIMATIC PCS 7 V7.1 Software
B)
PCS 7/OPEN OS Engineering Component Option V7.1 1 language (English), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: • License key memory stick, certificate of license including terms and conditions • CD "PCS 7/OPEN OS Option V7.1"
6EQ2 001-1XX17-3BA5
B)
B) Subject to export regulations: AL: N, ECCN: EAR99S
Software for combined engineering/operator station with 250 OS engineering and runtime POs (can be used for productive operation as operator station) PCS 7/OPEN OS Engineering Pack V7.1 (250 POs) 1 language (English), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Electronic documentation, on CD/DVD Type of delivery: • License key memory stick, certificate of license including terms and conditions • SIMATIC PCS 7 Data Medium Package V7.1 • CD "PCS 7/OPEN OS Option V7.1"
6EQ2 001-2BA17-3BA5
B)
PowerPacks for PO expansion See Catalog ST PCS 7, Chapter "Engineering System", Section "ES software"
10
Siemens ST PCS 7.2 · October 2009
10/5
© Siemens AG 2009
Integration of third-party controllers using PCS 7/OPEN OS Operator control and monitoring PCS 7/OPEN OS Operator System
■ Overview The PCS 7/OPEN OS software packages offered for the integration of third-party controllers into the process management of the SIMATIC PCS 7 V7.1 process control system are tailored to the architecture of the SIMATIC PCS 7 operator system. They support single station systems (single stations) as well as multi-user systems with up to 12 servers/redundant pairs of servers and up to 32 clients.
■ Design The following software components are required depending on the configuration of a PCS 7/OPEN OS operator system as single station or multi-user system (client/server architecture): PCS 7/OPEN OS architecture Single Station Components required
not redundant (OS type)
Multi-user system OS server
OS client
not redundant
Redundant pair
For the integration of third-party controllers into a new plant PCS 7/OPEN OS Single Station Pack V7.1
1
–
–
–
PCS 7/OPEN OS Server Pack V7.1 (PO 250)
–
1
–
–
PCS 7/OPEN OS Redundant Server Pack V7.1 (PO 250)
–
–
1
–
SIMATIC PCS 7 OS Software Client V7.11)
–
–
–
1
1
1
2
–
For the integration of third-party controllers into an existing plant PCS 7/OPEN OS Runtime Component Option V7.1 (ohne SIMATIC PCS 7 V7.1 Software) 1)
For further information and ordering information, refer to Catalog ST PCS 7, Chapter "Operator System", Section "OS Software".
PowerPacks as well as further software for PCS 7/OPEN OS operator systems can be ordered from Catalog ST PCS 7, Chapter "Operator System", Section "OS Software". Appropriate basic hardware for a PCS 7/OPEN OS operator station as a single station, server or client version can be found in the "SIMATIC PCS 7 Industrial Workstation" section of Catalog ST PCS 7. PCS 7/OPEN OS Runtime Packages V7.1 (single station/server/redundant server) The PCS 7/OPEN OS Runtime Packages V7.1 contain: • PCS 7 OS software runtime V7.1 (250 POs) for one OS single station, one OS server or two redundant OS servers (incl. WinCC/Redundancy and RS 232 connecting cable, 10 m) • PCS 7/OPEN OS runtime software option • License for the access to the A&E data of the OPC server
10
10/6
Siemens ST PCS 7.2 · October 2009
PCS 7/OPEN OS Runtime Component Option V7.1 The PCS 7/OPEN OS runtime component option V7.1 that can be installed on the OS single station and on the OS server is used for integrating third-party controllers into an existing SIMATIC PCS 7 V7.1 process control system. Consequently it is not equipped with SIMATIC PCS 7 OS Software V7.1 like the PCS 7/OPEN OS Runtime Packages V7.1 for the OS single station, the OS server or the redundant OS server pair.
© Siemens AG 2009
Integration of third-party controllers using PCS 7/OPEN OS Operator control and monitoring PCS 7/OPEN OS Operator System
■ Function
■ Ordering data
The PCS 7/OPEN OS Runtime Packages V7.1 enable the SIMATIC PCS 7 operator system to: • exchange data with the third-party controller via the appropriate OPC server • save the collected information in the runtime database • organize and display the process data and message/alarms in accordance with the configured plant hierarchy • make the data available for the OS clients and the central archive server (CAS) • synchronize the data between OS servers
■ Ordering data
Order No.
PCS 7/OPEN OS Runtime Packages incl. SIMATIC PCS 7 V7.1 Software PCS 7/OPEN OS Single Station Pack V7.1 (250 POs) 1 language (English), executes with Windows XP Professional, single license for 1 installation Electronic documentation, on CD/DVD Type of delivery: • License key memory stick, certificate of license including terms and conditions • SIMATIC PCS 7 Data Medium Package V7.1 • CD "PCS 7/OPEN OS Option V7.1"
6EQ2 001-2AA17-3BA0
PCS 7/OPEN OS Server Pack V7.1 (250 POs) 1 language (English), executes with Windows Server 2003, single license for 1 installation Type of delivery: • License key memory stick, certificate of license including terms and conditions • SIMATIC PCS 7 Data Medium Package V7.1 • CD "PCS 7/OPEN OS Option V7.1"
6EQ2 001-2HA17-3BA0
B)
Order No.
PCS 7/OPEN OS Redundant Server Pack V7.1 (250 POs) 1 language (English), executes with Windows Server 2003, single license for 2 installations, incl. WinCC/Redundancy and RS 232 connection cable, 10 m Type of delivery: • License key memory stick, certificate of license including terms and conditions • SIMATIC PCS 7 Data Medium Package V7.1 • CD "PCS 7/OPEN OS Option V7.1" • RS 232 connecting cable, 10 m
6EQ2 001-2GA17-3BA0
SIMATIC PCS 7 OS Software Client V7.1 5 languages (German, English, French, Italian, Spanish), executes with Windows XP Professional, floating license for 1 user (See Catalog ST PCS 7, Chapter "Operator System", Section "OS software")
6ES7 658-2CX17-0YA5
B)
PowerPacks for PO expansion See Catalog ST PCS 7, Chapter "Operator System", Section "OS software" PCS 7/OPEN OS Runtime Packages without SIMATIC PCS 7 V7.1 software for the integration of third-party controllers into an existing SIMATIC PCS 7.1 architecture B)
PCS 7/OPEN OS Runtime Component Option V7.1 1 language (English), executes with Windows XP Professional or Windows Server 2003, single license for 1 installation Type of delivery: • License key memory stick, certificate of license including terms and conditions • CD "PCS 7/OPEN OS Option V7.1"
6EQ2 001-2XX17-3BA0
B)
Individual components for redundancy retrofit WinCC/Redundancy V7.0 for archive comparison after OS restart; single license for 2 installations Installation is required on both of the redundant stations
6AV6 371-1CF07-0AX0
RS 232 connecting cable, 10 m
6ES7 902-1AC00-0AA0
B) Subject to export regulations: AL: N, ECCN: EAR99S
Siemens ST PCS 7.2 · October 2009
■
10/7
10
© Siemens AG 2009
Integration of third-party controllers using PCS 7/OPEN OS
10
10/8
Siemens ST PCS 7.2 · October 2009
11
© Siemens AG 2009
Integration FOUNDATION Fieldbus 11/2
Integration of FOUNDATION fieldbus
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Integration of FOUNDATION Fieldbus Integration of FOUNDATION fieldbus
■ Overview Engineering Station
OS clients
Asset Management/ Maintenance station
OS server Industrial Ethernet Automation system DP/FF Link
PROFIBUS DP FF-H1
Integration of FOUNDATION Fieldbus H1 in SIMATIC PCS 7 via DP/FF Link
By means of the DP/FF Link, Siemens offers the possibility for integrating FF H1 field devices into the SIMATIC PCS 7 process control system via PROFIBUS DP. The DP/FF Link supports cyclic and acyclic communication. The hardware configuration and the detailed diagnostics of the FF-H1 components conform to the system. The FF-H1 components can also be integrated into the SIMATIC PCS 7 Asset Management.
■ Design
■ Ordering data
• The router from PROFIBUS DP to the FOUNDATION Fieldbus H1 (FF-H1) is implemented using the DP/FF Link bundle which consists of the following components: - PROFIBUS DP interface module Anybus DP-Link - Fieldbus Interface Module 3420 (FIM 3420) for four FF-H1 segments • Expansion limits: - Max. 64 FF devices per DP/FF Link distributed between max. 4 FF-H1 segments with max. 16 FF devices each - Max. 8 digital input modules, 8 digital output modules, 32 analog input modules and 16 analog output modules • Central engineering of the DP/FF Link and FF field devices: - Configuration of PROFIBUS DP interface module of the DP/FF Link on the PROFIBUS DP master system using HW-Config - Configuration of the FF segment including "control in the field" applications, as well as parameterization of the FF field devices per Web interface via Ethernet
11
11/2
The FF H1 integration into SIMATIC PCS 7 supports "control in the field", i.e. control with suitable field devices independent of the control system’s controller.
Siemens ST PCS 7.2 · October 2009
Order No.
Router from PROFIBUS DP to FOUNDATION Fieldbus H1 DP/FF Link bundle consisting of: • PROFIBUS DP interface module Anybus DP-Link • Fieldbus Interface Module 3420
6DL4 400-1AA
A) Subject to export regulations: AL: N, ECCN: EAR99H
A)
■
12
© Siemens AG 2009
Appendix 12/2
Partner at Industry Automation and Drive Technologies
12/3
Online Services
12/4
Service & Support
12/6
Siemens Solution Partner Automation and Power Distribution
12/7
Software Licenses
12/8
Index
12/9
Ordering data summary
12/10 12/10
Catalog improvement suggestions Fax form
12/12
Conditions of sale and delivery Export regulations
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Appendix Partner at Industry Automation and Drive Technologies At Siemens Industry Automation and Drive Technologies, more than 85,000 people are resolutely pursuing the same goal: longterm improvement of your competitive ability. We are committed to this goal. Thanks to our commitment, we continue to set new standards in automation and drive technology. In all industries worldwide. At your service locally, around the globe for consulting, sales, training, service, support, spare parts... on the entire Industry Automation and Drive Technologies range. Your personal contact can be found in our Contacts Database at: http://www.siemens.com/automation/partner You start by selecting a • Product group, • Country, • City, • Service.
12 12/2
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Appendix Online Services Information and Ordering in the Internet and on DVD
■ Siemens Industry Automation and Drive Technologies in the WWW A detailed knowledge of the range of products and services available is essential when planning and configuring automation systems. It goes without saying that this information must always be fully up-to-date. Siemens Industry Automation and Drive Technologies has therefore built up a comprehensive range of information in the World Wide Web, which offers quick and easy access to all data required. Under the address http://www.siemens.com/automation you will find everything you need to know about products, systems and services.
■ Product Selection Using the Offline Mall of Industry Detailed information together with convenient interactive functions: The Offline Mall CA 01 covers more than 80,000 products and thus provides a full summary of the Siemens Industry Automation and Drive Technologies product base. Here you will find everything that you need to solve tasks in the fields of automation, switchgear, installation and drives. All information is linked into a user interface which is easy to work with and intuitive. After selecting the product of your choice you can order at the press of a button, by fax or by online link. Information on the Offline Mall CA 01 can be found in the Internet under http://www.siemens.com/automation/ca01 or on DVD.
■ Easy Shopping with the Industry Mall The Industry Mall is the virtual department store of Siemens AG in the Internet. Here you have access to a huge range of products presented in electronic catalogs in an informative and attractive way. Data transfer via EDIFACT allows the whole procedure from selection through ordering to tracking of the order to be carried out online via the Internet. Numerous functions are available to support you. For example, powerful search functions make it easy to find the required products, which can be immediately checked for availability. Customer-specific discounts and preparation of quotes can be carried out online as well as order tracking and tracing. Please visit the Industry Mall on the Internet under: http://www.siemens.com/automation/mall
12 Siemens ST PCS 7.2 · October 2009
12/3
© Siemens AG 2009
Appendix Service & Support Services covering the entire life cycle
■ Technical Consulting Support in the planning and designing of your project from detailed actual-state analysis, target definition and consulting on product and system questions right to the creation of the automation solution.
■ Engineering Support Support in configuring and developing with customer-oriented services from actual configuration to implementation of the automation project.
.I
Our Service & Support accompanies you worlwide in all concerns related to the automation and drive technology of Siemens. In more than 100 countries directly on site and covering all phases of the life cycle of your machines and plants. Round the clock. An experienced team of specialists with their combined knowhow is ready to assist you. Regular training courses and a close contact of our employees among each other - also across continents - assure a reliable service for multifaceted scopes.
■ Field Service With Field Service, we offer services for startup and maintenance essential for ensuring system availability.
■ Online Support The comprehensive information system available round the clock via Internet ranging from Product Support and Service & Support services to Support Tools in the Shop. http://www.siemens.com/ automation/service&support
■ Spare Parts and Repairs In the operating phase of a machine or automation system, we provide a comprehensive repair and spare parts service ensuring the highest degree of plant availability.
■ Technical Support Competent consulting in technical questions covering a wide range of customer-oriented services for all our products and systems. http://www.siemens.com/ automation/support-request
■ Optimization and Upgrading After startup or during the operating phase, additional potential for inceasing the productiviy or for reducing costs often arises. For this purpose, we offer you high-quality services in optimization and upgrading.
12 You find contact details in the Internet under: http://www.siemens.com/automation/service&support
12/4
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Appendix Service & Support ■ Knowledge Base on DVD For locations without online connections to the Internet there are excerpts of the free part of the information sources available on DVD (Service & Support Knowledge Base). This DVD contains all the latest product information at the time of production (FAQs, Downloads, Tips and Tricks, Updates) as well as general information on Service & Support.
The DVD also includes a full-text search and our Knowledge Manager for targeted searches for solutions. The DVD will be updated every 4 months. Just the same as our online offer in the Internet, the Service & Support Knowledge Base on DVD comes complete in 5 languages (German, English, French, Italian, Spanish). You can order the Service & Support Knowledge Base DVD from your Siemens contact. Order no. 6ZB5310-0EP30-0BA2
■ Automation Value Card By entering the card number and PIN you have full access to the Service & Support services being offered. The charge for the services procured is debited from the credits on your Automation Value Card. All the services offered are marked in currency-neutral credits, so you can use the Automation Value Card worldwide. Order your Automation and Value Card easily and comfortably like a product with your sales contact. Automation Value Card order numbers Credits
Small card - great support The Automation Value Card is an integral component of the comprehensive service concept with which Siemens Automation and Drives will accompany you in each phase of your automation project.
Order no.
200
6ES7 997-0BA00-0XA0
500
6ES7 997-0BB00-0XA0
1000
6ES7 997-0BC00-0XA0
10000
6ES7 997-0BG00-0XA0
Detailed information on the services offered is available on our Internet site at: http://www.siemens.com/automation/service&support Service & Support à la Card: Examples Technical Support
It doesn't matter whether you want just specific services from our Technical Support or want to purchase something on our Online portal, you can always pay with your Automation Value Card. No invoicing, transparent and safe. With your personal card number and associated PIN you can view the state of your account and all transactions at any time.
”Priority“
Priority processing for urgent cases
”24 h“
Availability round the clock
”Extended“
Technical consulting for complex questions
”Mature Products“
Consulting service for products that are not available any more
Services on card. This is how it's done.
Support Tools in the Support Shop
Card number and PIN are on the back of the Automation Value Card. When delivered, the PIN is covered by a scratch field, guaranteeing that the full credit is on the card.
Tools that can be used directly for configuration, analysis and testing
12 Siemens ST PCS 7.2 · October 2009
12/5
© Siemens AG 2009
Appendix Siemens Solution Partner Automation and Power Distribution
■ Overview Solution Partner
The Solution Partner Finder, available to you on the Internet, is a comprehensive database in which all Solution Partners, together with their performance profiles, present themselves.
Automation
s
In addition to the search criteria Technology, Sector and Country, you can also search by Company and ZIP Code. From there it is only a small step to making the first contact.
s
Call up the Solution Partner Finder as follows: • CA 01 on CD-ROM: On the start page via "Contacts & Partners; Siemens Solution Partner Automation and Power Distribution" • CA 01 online: Go directly to the Solution Partner Finder: www.siemens.com/automation/partnerfinder
Solution Partner Power Distribution
Products and systems from Siemens Automation and Drives provide the ideal platform for all automation tasks. Siemens Solution Partners offer customized future-proof solutions with products and systems from Siemens Automation and Drives. The basis: qualified product and system knowledge coupled with a high degree of solutions and industry-related expertise. In the Siemens Solution Partner Program you are certain to find the optimum partner for your specific requirements. Since more than 570 companies worldwide belong to the program, you can be sure to get expert support at your location.
12 12/6
Siemens ST PCS 7.2 · October 2009
Additional information about the Siemens Solution Partner Program is available in the Internet at: www.siemens.com/automation/solutionpartner
© Siemens AG 2009
Appendix Software Licenses ■ Overview Software types Software requiring a license is categorized into types. The following software types have been defined: • Engineering software • Runtime software
Factory license With the Factory License the user has the right to install and use the software at one permanent establishment only. The permanent establishment is defined by one address only.The number of hardware devices on which the software may be installed results from the order data or the Certificate of License (CoL).
Engineering software This includes all software products for creating (engineering) user software, e.g. for configuring, programming, parameterizing, testing, commissioning or servicing. Data generated with engineering software and executable programs can be duplicated for your own use or for use by thirdparties free-of-charge.
Certificate of license The Certificate of License (CoL) is the licensee's proof that the use of the software has been licensed by Siemens. A CoL is required for every type of use and must be kept in a safe place.
Runtime software This includes all software products required for plant/machine operation, e.g. operating system, basic system, system expansions, drivers, etc. The duplication of the runtime software and executable programs created with the runtime software for your own use or for use by third-parties is subject to a charge. You can find information about license fees according to use in the ordering data (e.g. in the catalog). Examples of categories of use include per CPU, per installation, per channel, per instance, per axis, per control loop, per variable, etc. Information about extended rights of use for parameterization/configuration tools supplied as integral components of the scope of delivery can be found in the readme file supplied with the relevant product(s). License types Siemens Automation & Drives offers various types of software license: • Floating license • Single license • Rental license • Trial license Floating license The software may be installed for internal use on any number of devices by the licensee. Only the concurrent user is licensed. The concurrent user is the person using the program. Use begins when the software is started. A license is required for each concurrent user. Single license Unlike the floating license, a single license permits only one installation of the software. The type of use licensed is specified in the ordering data and in the Certificate of License (CoL). Types of use include for example per device, per axis, per channel, etc. One single license is required for each type of use defined. Rental license A rental license supports the "sporadic use" of engineering software. Once the license key has been installed, the software can be used for a specific number of hours (the operating hours do not have to be consecutive). One license is required for each installation of the software. Trial license A trial license supports "short-term use" of the software in a nonproductive context, e.g. for testing and evaluation purposes. It can be transferred to another license.
Downgrading The licensee is permitted to use the software or an earlier version/release of the software, provided that the licensee owns such a version/release and its use is technically feasible. Delivery versions Software is constantly being updated. The following delivery versions • PowerPack • Upgrade can be used to access updates. Existing bug fixes are supplied with the ServicePack version. PowerPack PowerPacks can be used to upgrade to more powerful software. The licensee receives a new license agreement and CoL (Certificate of License) with the PowerPack. This CoL, together with the CoL for the original product, proves that the new software is licensed. A separate PowerPack must be purchased for each original license of the software to be replaced. Upgrade An upgrade permits the use of a new version of the software on the condition that a license for a previous version of the product is already held. The licensee receives a new license agreement and CoL with the upgrade. This CoL, together with the CoL for the previous product, proves that the new version is licensed. A separate upgrade must be purchased for each original license of the software to be upgraded. ServicePack ServicePacks are used to debug existing products. ServicePacks may be duplicated for use as prescribed according to the number of existing original licenses. License key Siemens Automation & Drives supplies software products with and without license keys. The license key serves as an electronic license stamp and is also the "switch" for activating the software (floating license, rental license, etc.). The complete installation of software products requiring license keys includes the program to be licensed (the software) and the license key (which represents the license). Detailed explanations concerning license conditions can be found in the “Terms and Conditions of Siemens AG” or under http://www.siemens.com/automation/mall (Industry Mall Online-Help System) A&D/Software licenses/En 03.08.06
12 Siemens ST PCS 7.2 · October 2009
12/7
© Siemens AG 2009
Appendix Index ■ A
P
ABB Contronic P ..................................................................................... 8/2 Alarm management ................................................................................ 2/7 APACS+ .................................................................................................. 3/2
PCS 7/505 Operator System ...................................................................4/6 PCS 7/505 OS Engineering Station .........................................................4/4 PCS 7/90 Operator System .....................................................................6/6 PCS 7/90 OS Engineering Station ...........................................................6/4 PCS 7/APACS+ Operator System..........................................................3/11 PCS 7/APACS+ OS Engineering Station ...............................................3/14 PCS 7/OPEN OS ....................................................................................10/2 PCS 7/OPEN OS Engineering Station ...................................................10/4 PCS 7/OPEN OS Operator System........................................................10/6 PCS 7/OPMC OS Engineering Station.....................................................5/4 PCS 7/OPMC Operator System ...............................................................5/5 PCS 7/TM-EA ...........................................................................................2/4 PCS 7/TM-OCX (NORA) ..........................................................................2/6 PCS 7/TM-OS ..........................................................................................2/5 PROGRAF AS ........................................................................................2/10
B Bailey INFI 90/NET 90............................................................................. 6/2
C CM104_TSAA.......................................................................................... 9/2 Contronic P ............................................................................................. 8/2 CP 1613 A2............................................................................................. 2/9 CS 275 .................................................................................................. 2/13
D Database Automation ........................................................................... 1/11 DBA....................................................................................................... 1/11 DP/FFLink.............................................................................................. 11/2 DP/IO Bus Link................................................................................. 3/4, 3/7
Q
E
QUADLOG...............................................................................................3/2
ES 902 connector ................................................................................. 2/14
R
F
Redundancy cable ..................................................................................3/6
FOUNDATION Fieldbus ........................................................................ 11/2 FTA modules ........................................................................................... 7/3
S
G Gateway CM104_TSAA .......................................................................... 9/2 Gateway GT104CS ............................................................................... 2/15 GF blocks (TELEPERM M) ...................................................................... 2/7
H Honeywell TDC ....................................................................................... 7/2
I IEM........................................................................................................ 3/17 Industrial Ethernet Module.................................................................... 3/17 Invensys Triconex ................................................................................... 9/2
K Coupling package (PCS 7/TM-OS)................................................ 2/6, 2/11
M M bus .................................................................................................... 3/11 Memory Calculator........................................................................... 3/5, 3/8
N Node-to-Node redundancy..................................................................... 3/9 NORA...................................................................................................... 2/6 N-PCI .................................................................................................... 2/14
O OpenPMC ............................................................................................... 5/2
12 12/8
Siemens ST PCS 7.2 · October 2009
SIMATIC BATCH ....................................................................2/7, 3/12, 3/15 SIMATIC PCS...........................................................................................4/2 Smart Alarm Hiding .................................................................................2/7
T TELEPERM M ..........................................................................................2/2 Third-party controller .............................................................................10/2 TISTAR .....................................................................................................4/2 Transition Board.......................................................................................3/4 Triconex ...................................................................................................9/2
© Siemens AG 2009
Appendix Ordering data summary ■ 6DL4 400-1AA ..................................................................................... 11/2 6DL5 900-8AX03-8YX8 .......................................................................... 2/3
6EQ2 013-0CE00-0XA0 6EQ2 013-0CE10-0XA0 6EQ2 013-0CE20-0XA0 6EQ2 013-0CE60-0XA0 6EQ2 013-1CE00-0XA0
6DP1 724-8BA ..................................................................................... 2/14
6EQ2 014-0CE00-0XA0 ..........................................................................3/6
6DS5 037-1AX .............................................................................. 2/8, 2/11 6DS5 128-1XX00-2XX3 .......................................................................... 2/9 6DS5 128-1XX00-2XX4 .......................................................................... 2/9 6DS5 128-1XX03-2XX4 .......................................................................... 2/9 6DS5 128-1XX70-2XX4 .......................................................................... 2/9 6DS5 128-1XX73-2XX4 .......................................................................... 2/9 6DS5 143-1AX ....................................................................................... 2/8 6DS5 143-1AX ..................................................................................... 2/11
6EQ2 020-0AB12-5XX0 ........................................................................3/17
6DS8 208-8KC ..................................................................................... 2/14 6DS8 210-8MB ..................................................................................... 2/14 6DS8 210-8MC .................................................................................... 2/14 6DS8 210-8SC ..................................................................................... 2/14 6DS8 211-8AD ..................................................................................... 2/14 6DS8 211-8ED ..................................................................................... 2/14 6DS8 211-8SB ..................................................................................... 2/14 6DS8 211-8SC ..................................................................................... 2/14 6DS8 212-8EC ..................................................................................... 2/14 6DS8 212-8MB ..................................................................................... 2/14 6DS8 212-8MC .................................................................................... 2/14 6DS8 212-8SC ..................................................................................... 2/14
6ES7 652-5CX07-0YE5 ....................................................................4/7, 6/7
6AV6 371-1CF07-0AX0 ........................................................................ 10/7 6BQ3 074-2AA03-0CA0 ......................................................................... 5/6
6DS9 200-8AA ..................................................................................... 2/14 6EQ2 000-1AX16-2BB5 ....................................................................... 3/16 6EQ2 000-1XX07-3BE5 ........................................................................ 3/16 6EQ2 000-2AB07-3BA0 ....................................................................... 3/12 6EQ2 000-2BB07-3BA0 ....................................................................... 3/12 6EQ2 000-2DB07-3BA0 ....................................................................... 3/12 6EQ2 000-2EB07-3BA5 ....................................................................... 3/16 6EQ2 000-2XX07-3BE0 ........................................................................ 3/13 6EQ2 000-3AE07-3BA0 ......................................................................... 4/7 6EQ2 000-3BE07-3BA0 ......................................................................... 4/7 6EQ2 000-3DE07-3BA0 ......................................................................... 4/7 6EQ2 000-3EB07-3BA5 ....................................................................... 3/16 6EQ2 000-3ED07-3BA5 ......................................................................... 4/5 6EQ2 000-3EE07-3BA5 ......................................................................... 4/5 6EQ2 000-3XX07-3BE0 .......................................................................... 4/7 6EQ2 000-3XX07-3BE5 .......................................................................... 4/5 6EQ2 000-5XX07-2BB0 ....................................................................... 3/16 6EQ2 000-6XX07-2BB0 ....................................................................... 3/13 6EQ2 001-1BB17-3BA5 6EQ2 001-1XX17-3BA5 6EQ2 001-2AA17-3BA0 6EQ2 001-2BA17-3BA5 6EQ2 001-2GA17-3BA0 6EQ2 001-2HA17-3BA0 6EQ2 001-2XX17-3BA0
........................................................................3/10 .................................................................3/6, 3/10 ........................................................................3/10 ........................................................................3/10 .................................................................3/6, 3/10
6ES7 648-0DC40-0AA0 ........................................................................3/17 6ES7 650-0NF17-0YX0 ..................................................................2/7, 2/11 6ES7 650-0NG17-0YA0 ..........................................................................2/8 6ES7 650-0NG17-0YB0 ..........................................................................2/8 6ES7 650-0NG17-0YX0 ..........................................................................2/8 6ES7 650-0NH17-0YX0 .................................................................2/8, 2/11
6ES7 654-8EM..-..B. ...............................................................................3/6 6ES7 654-8EN..-..B. ..............................................................................3/10 6ES7 656-8EM..-..B. ...............................................................................3/6 6ES7 656-8EN..-..B. ..............................................................................3/10 6ES7 658-2CX07-0YA5 ....................................................3/13, 4/7, 5/6, 6/7 6ES7 658-2CX17-0YA5 .........................................................................10/7 6ES7 658-5AF17-0YA5 .........................................................................2/11 6ES7 902-1AC00-0AA0 ........................................................................10/7 6GK1 161-3AA01 ..........................................................................2/9, 2/12 6GK1 162-3AA00 .................................................................................2/12 6GK1 716-0HB71-3AA0 ................................................................2/9, 2/12 6GK1 716-0HB71-3AC0 ................................................................2/9, 2/12 6GK1 716-1CB71-3AA0 ................................................................2/9, 2/12 9AE4 100-1EA00 ..................................................................................2/15 UPH:16413-16 ......................................................................................3/13 UPH:39PSR6OVP .................................................................................3/10
....................................................................... 10/5 ....................................................................... 10/5 ....................................................................... 10/7 ....................................................................... 10/5 ....................................................................... 10/7 ....................................................................... 10/7 ....................................................................... 10/7
6EQ2 003-1BA07-3BA5 ......................................................................... 6/5 6EQ2 003-1BD07-3BA5 ......................................................................... 6/5 6EQ2 003-1XX07-3BE5 .......................................................................... 6/5 6EQ2 003-2AA07-3BA0 ......................................................................... 6/7 6EQ2 003-2GA07-3BA0 ......................................................................... 6/7 6EQ2 003-2HA07-3BA0 ......................................................................... 6/7 6EQ2 003-2XX07-3BE0 .......................................................................... 6/7 6EQ2 008-1BA07-3BA5 6EQ2 008-2AA07-3BA0 6EQ2 008-2GA07-3BA0 6EQ2 008-2HA07-3BA0
......................................................................... 5/4 ......................................................................... 5/6 ......................................................................... 5/6 ......................................................................... 5/6
6EQ2 012-1BA10-3BA0 6EQ2 012-1BB10-2BA0 6EQ2 012-1BC11-4BA0 6EQ2 012-1BC21-4BA0 6EQ2 012-1BD11-3BA0 6EQ2 012-1BD21-3BA0 6EQ2 012-1BD32-3BA0 6EQ2 012-2BD30-0BA0 6EQ2 012-2BE30-0BA0
......................................................................... 7/4 ......................................................................... 7/4 ......................................................................... 7/4 ......................................................................... 7/4 ......................................................................... 7/4 ......................................................................... 7/4 ......................................................................... 7/4 ......................................................................... 7/4 ......................................................................... 7/4
12 Siemens ST PCS 7.2 · October 2009
12/9
© Siemens AG 2009
Appendix Catalog improvement suggestions Fax form
■ To
Your adress
Siemens AG I IA SE ITS PRI 4 ST PCS 7.2/ Mr. Strozyk Östl. Rheinbrückenstr. 50 76187 Karlsruhe
Name
Fax: +49 (721) 595-6623
Job
E-mail:
[email protected] Company/Department
Street/No.
Postal code/City
Tel. No./Fax
E-mail address
■ Your opinion is important to us! Our catalog should be an important and frequently used document. For this reason we are continuously endeavoring to improve it.
A small request on our part to you: Please take time to fill in the following form and fax it to us. Thank You!
■ We invite you to grade our catalog on a point system from 1 (= good) to 6 (= poor): Do the contents of the catalog live up to your expectations?
Do the technical details meet your expectations?
Is the information easy to find?
How would you assess the graphics and tables?
Can the texts be readily understood?
■ Did you find any printing errors?
12 12/10
Siemens ST PCS 7.2 · October 2009
© Siemens AG 2009
Appendix Notes
12 Siemens ST PCS 7.2 · October 2009
12/11
© Siemens AG 2009
Appendix Conditions of sale and delivery Export regulations
■ Terms and Conditions of Sale and Delivery By using this catalog you can acquire hardware and software products described therein from Siemens AG subject to the following terms. Please note! The scope, the quality and the conditions for supplies and services, including software products, by any Siemens entity having a registered office outside of Germany, shall be subject exclusively to the General Terms and Conditions of the respective Siemens entity. The following terms apply exclusively for orders placed with Siemens AG. For customers with a seat or registered office in Germany The “General Terms of Payment” as well as the “General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry” shall apply. For software products, the “General License Conditions for Software Products for Automation and Drives for Customers with a Seat or registered Office in Germany” shall apply. For customers with a seat or registered office outside of Germany The “General Terms of Payment” as well as the “General Conditions for Supplies of Siemens, Automation and Drives for Customers with a Seat or registered Office outside of Germany” shall apply. For software products, the “General License Conditions for Software Products for Automation and Drives for Customers with a Seat or registered Office outside of Germany” shall apply. General The dimensions are in mm. In Germany, according to the German law on units in measuring technology, data in inches only apply to devices for export. Illustrations are not binding. Insofar as there are no remarks on the corresponding pages, - especially with regard to data, dimensions and weights given these are subject to change without prior notice. The prices are in € (Euro) ex works, exclusive packaging. The sales tax (value added tax) is not included in the prices. It shall be debited separately at the respective rate according to the applicable legal regulations. Prices are subject to change without prior notice. We will debit the prices valid at the time of delivery. Surcharges will be added to the prices of products that contain silver, copper, aluminum, lead and/or gold if the respective basic official prices for these metals are exceeded. These surcharges will be determined based on the official price and the metal factor of the respective product. The surcharge will be calculated on the basis of the official price on the day prior to receipt of the order or prior to the release order. The metal factor determines the official price as of which the metal surcharges are charged and the calculation method used. The metal factor, provided it is relevant, is included with the price information of the respective products.
12 12/12
Siemens ST PCS 7.2 · October 2009
An exact explanation of the metal factor and the text of the Comprehensive Terms and Conditions of Sale and Delivery are available free of charge from your local Siemens business office under the following Order Nos.: • 6ZB5310-0KR30-0BA1 (for customers based in Germany) • 6ZB5310-0KS53-0BA1 (for customers based outside Germany) or download them from the Internet http://www.siemens.com/automation/mall (Germany: Industry Mall Online-Help System)
■ Export regulations The products listed in this catalog / price list may be subject to European / German and/or US export regulations. Therefore, any export requiring a license is subject to approval by the competent authorities. According to current provisions, the following export regulations must be observed with respect to the products featured in this catalog / price list: AL
Number of the German Export List Products marked other than “N” require an export license. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an “AL“ not equal to “N” are subject to a European or German export authorization when being exported out of the EU.
ECCN
Export Control Classification Number Products marked other than “N” are subject to a reexport license to specific countries. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an “ECCN“ not equal to “N” are subject to a US re-export authorization.
Even without a label or with an “AL: N” or “ECCN: N”, authorization may be required due to the final destination and purpose for which the goods are to be used. The deciding factors are the AL or ECCN export authorization indicated on order confirmations, delivery notes and invoices. Errors excepted and subject to change without prior notice. I IA/DT /VuL_ohne MZ/En 12.05.09
© Siemens AG 2009
Catalogs Industry Automation, Drive Technologies and Low Voltage Distribution Further information can be obtained from our branch offices listed in the appendix or at www.siemens.com/automation/partner Interactive Catalog on DVD for Industry Automation, Drive Technologies and Low Voltage Distribution
Catalog CA 01
Drive Systems Variable-Speed Drives SINAMICS G110, SINAMICS G120 Standard Inverters SINAMICS G110D, SINAMICS G120D Distributed Inverters
D 11.1
SINAMICS G130 Drive Converter Chassis Units SINAMICS G150 Drive Converter Cabinet Units
D 11
SINAMICS GM150, SINAMICS SM150 Medium-Voltage Converters
D 12
SINAMICS S120 Chassis Format Units and Cabinet Modules SINAMICS S150 Converter Cabinet Units
D 21.3
Three-phase Induction Motors
D 84.1
Catalog
Motion Control SINUMERIK & SIMODRIVE Automation Systems for Machine Tools
NC 60
SINUMERIK & SINAMICS Automation Systems for Machine Tools
NC 61
SIMOTION, SINAMICS S120 and Motors for Production Machines
PM 21
SINAMICS S110 The Basic Positioning Drive
PM 22
Low-Voltage Controls and Distribution – SIRIUS, SENTRON, SIVACON
LV 1
Controls and Distribution – Technical Information SIRIUS, SENTRON, SIVACON
LV 1 T
SICUBE System Cubicles and Cubicle Air-Conditioning LV 50
• H-compact • H-compact PLUS
SIDAC Reactors and Filters
LV 60
SIVACON 8PS Busbar Trunking Systems
LV 70
Asynchronous Motors Standardline
D 86.1
Synchronous Motors with Permanent-Magnet Technology, HT-direct
D 86.2
Power Supply and System Cabling Power supplies SITOP power and LOGO! Power
KT 10.1
DC Motors
DA 12
System cabling SIMATIC TOP connect
KT 10.2
SIMOREG DC MASTER 6RA70 Digital Chassis Converters
DA 21.1
SIMOREG K 6RA22 Analog Chassis Converters
DA 21.2
Process Instrumentation and Analytics Field Instruments for Process Automation
FI 01
PDF: SIMOREG DC MASTER 6RM70 Digital Converter Cabinet Units
DA 22
PDF: Indicators for panel mounting
MP 12
SIREC Recorders and Accessories
MP 20
SIMOVERT PM Modular Converter Systems
DA 45
SIPART, Controllers and Software
MP 31
SIEMOSYN Motors
DA 48
PDF: Products for Weighing Technology
WT 10
MICROMASTER 420/430/440 Inverters
DA 51.2
Process Analytical Instruments
PA 01
MICROMASTER 411/COMBIMASTER 411
DA 51.3
PA 11
SIMOVERT MASTERDRIVES Vector Control
DA 65.10
PDF: Process Analytics, Components for the System Integration
SIMOVERT MASTERDRIVES Motion Control
DA 65.11
Synchronous and asynchronous servomotors for SIMOVERT MASTERDRIVES
DA 65.3
SIMODRIVE 611 universal and POSMO
DA 65.4
SIMOTION, SINAMICS S120 and Motors for Production Machines
PM 21
SINAMICS S110 The Basic Positioning Drive
PM 22
Low-Voltage Three-Phase-Motors IEC Squirrel-Cage Motors
D 81.1
MOTOX Geared Motors
D 87.1
Automation Systems for Machine Tools SIMODRIVE
NC 60
• Motors • Converter Systems SIMODRIVE 611/POSMO Automation Systems for Machine Tools SINAMICS
ST 80
SIMATIC Industrial Automation Systems Products for Totally Integrated Automation and Micro Automation
ST 70
SIMATIC PCS 7 Process Control System
ST PCS 7
Add-ons for the SIMATIC PCS 7 Process Control System
ST PCS 7.1
Migration solutions with the SIMATIC PCS 7 Process Control System
ST PCS 7.2
pc-based Automation
ST PC
SIMATIC Control Systems
ST DA
SIMATIC NET Industrial Communication
IK PI
SIMATIC Sensors Sensors for Factory Automation
FS 10
NC 61
• Motors • Drive System SINAMICS S120 Drive and Control Components for Hoisting Equipment
SIMATIC HMI Human Machine Interface Systems
HE 1
Mechanical Driving Machines Flender Standard Couplings
MD 10.1
Electrical Installation Technology PDF: ALPHA Distribution Boards and Terminal Blocks
ET A1
PDF: ALPHA 8HP Molded-Plastic Distribution System
ET A3
PDF: BETA Low-Voltage Circuit Protection
ET B1
PDF: DELTA Switches and Socket Outlets
ET D1
PDF: GAMMA Building Management Systems
ET G1
System Solutions Applications and Products for Industry are part of the interactive catalog CA 01 TELEPERM M Process Control System PDF: AS 488/TM automation systems
PLT 112
PDF: These catalogs are only available as pdf files. IA DT LV/3U/En 05.10.09
© Siemens AG 2009
Siemens AG Industry Sector Industrial Automation Systems Postfach 48 48 90026 NÜRNBERG GERMANY
Subject to change without prior notice PDF (E86060-K4678-A131-A4-7600) 3P.8115.56.10 KG 1009 108 En Printed in Germany © Siemens AG 2009
www.siemens.com/simatic-pcs7
The information provided in this catalog contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.