To learn more, scan the code with your smartphone, or visit heatilator.com. Novus direct vent & b-vent gas fireplaces. Traditional Style, Proven Value. The Novus ...
Novus direct vent & b-vent gas fireplaces

Novus direct vent & b-vent gas fireplaces

Cover: Novus shown with optional demi front in bronze, traditional refractory, plymouth mantel and absolute black granite. Above: Novus shown with plymouth mantel and absolute black granite.

Traditional Style, Proven Value The Novus is the best-selling gas fireplace of all time. Why? Stylish design elements and robust fires—paired with the proven value and dependability of Heatilator. Glowing embers, realistic logs and endless finishing options add character to any space. Trust in the industry’s most recognized brand. The Novus will deliver. Features • 30", 33", 36" or 42" viewing areas • Many installation possibilities including tight spaces and corners • Make it your own with multiple fronts, finishes and traditional or herringbone panels

IntelliFireTM Ignition System

Direct Vent Technology

The IntelliFire™ Ignition System (IPI) is an advanced intermittent

Direct Vent fireplaces remove 100% of combustion exhaust and odors

pilot ignition system. IPI constantly monitors ignition, ensures safe

outside of the home. These sealed fireplaces provide optimal heat,

functioning and conserves up to $10/month in energy costs.

conserve energy and ensure clean, safe indoor air quality.

To learn more, scan the code with your smartphone, or visit heatilator.com.

To learn more, scan the code with your smartphone, or visit heatilator.com.

Options Fronts

Front Finishes

Refractory

Finish options shown available for the optional Demi front.

Black

Bronze

Traditional Refractory

Demi Non-Operable Front

Controls TotalRemote This remote control effortlessly manages heat output

SmartRemote An added level of function and convenience in a

and comfort level. For fireplaces and inserts.

remote control. For fireplaces, stoves, inserts, and gas logs with or without line power.

Models: RCT-MLT-HTL

Models: SMARTBATTHTL-B, SMART-STAT-HTL

Features: Hardwired Receiver, Timer Mode, Thermostat Mode,

Features: Battery-Powered or Hardwired Receiver, Timer Mode,

Room Temperature Readout, Flame High/Low, Fan Speed, On/Off

Thermostat Mode, Room Temperature Readout, On/Off

IntelliSwitch200 This wall switch is designed exclusively for Heatilator fireplaces with the IntelliFire ignition system. Models: WSK200-HTL Features: On/Off, Auto Battery Backup, Battery Strength Indicator, Pilot Activation, Fan Speed

Additional Options Not Pictured • •

Fan Kit Outside Air Kit (for B-vent models only)

• •

Venting Gas Conversion Kits Mantels and Surrounds

• •

Direct Vent: DVP pipe B-Vent: 5" B-vent pipe

Models* Available Model

BTU/HR Input(NG)

Opening Size

NBV/NDV3630I

14,000 - 20,000

30" (762mm)

NBV/NDV3933I

15,000 - 22,000

33" (838mm)

NBV/NDV4236I

17,000 - 25,000

36" (914mm)

NBV/NDV4842I

20,500 - 30,000

42" (1067mm)

U.S. Efficiencies Steady State - Since most homeowners use their fireplaces for an extended time while they are in the room, Steady State measures how efficiently your fireplace converts fuel to heat once it is warmed up and running in a “steady state”.

Rating

NDV3630

NDV3933

NDV4236

NDV4842

Steady State

75%

78%

73%

77%

AFUE

52%

48%

52%

56%

Rating

NDV3630

NDV3933

NDV4236

NDV4842

55%

51%

54%

58%

AFUE - AFUE rating is more typically used with appliances, like your furnace, that continually cycle on and off to maintain a constant temperature.

Canada Efficiencies EnerGuide (CSA P.4.1-02) - EnerGuide is a rating used in Canada to measure annual fireplace efficiency.

EnerGuide

(CSA P.4.1-02)

Value | Dependability | Most Recognized Brand

Technical Specifications Model

Front width (A)

Back width (C)

Height

Depth

Glass size (b)

NBV/NDV3630I

35" (889mm)

8-5/8" (219mm)

34" (864mm)

19-1/8" (486mm)

30"w x 22-5/8"h

NBV/NDV3933I C

C 38" (965mm)

11-5/8" (279mm)

34" (864mm)

19-1/8" (486mm)

33"w x 22-5/8"h

NBV/NDV4236I

41" (1041mm)

14-5/8" (371mm)

34" (864mm)

19-1/8" (486mm)

36"w x 22-5/8"h

34" (864mm)

19-1/8" (486mm)

42"w x 22-5/8"h

C

C

19-1/8 in.

NBV/NDV4842I

19-1/8 in.

11-5/8in. 11-5/8in. Left Side

A

47" (1194mm)

Front

A

23-1/2 in.

11-5/8 11-5/8 in. in.Right

A A

C 31-1/2 in.

31-1/2 in. 2-3/8 in.

34 in.

19-1/8 in.

6-1/2 in.

20-5/8"23-1/2 (508mm) in.

C

Gas Line

Gas Line Access Access

6-1/2 in.

19-1/8 in.

19-1/8 in.

2-3/8 in.

34 in.

B

3 in.

A

Gas Access

8 in.

6-1/2B in.

1-3/4 in.

3 in.

D

B

F

(498mm)

(1102mm)

(1194mm)

39"

35-1/2"

19-5/8"

43-3/8"

47"

42"

37-5/8"

19-5/8"

41-7/8"

19-5/8"

NBV/NDV4236I

(1067mm)

NBV/NDV4842I

(1219mm)

48"

(902mm) (956mm)

(1064mm)

(498mm) (498mm) (498mm)

43-3/8"

E

19-5/8"

(851mm)

(1102mm)

43-3/8"

(1102mm)

43-3/8"

(1102mm)

B

C

A

Drywall

47"

(1194mm)

47"

Alcove Installation

A

Model

A

B

c

d

6-1/2 in.

Rough Opening 1-3/4 in. (width)

Rough Opening (height)

Rough Opening (depth)

Rough Opening (dvp pipe)

3 in.

D

Rough Opening (slp pipe)

(940mm)

40"

NBV/NDV3630I

36" (914mm)

34-7/8" (886mm)

19-5/8" (498mm)

10" (254mm)

9" (229mm)

43"

NBV/NDV3933I

39" (991mm)

34-7/8" (886mm)

19-5/8" (498mm)

10" (254mm)

9" (229mm)

49"

NBV/NDV4236I

42" (1067mm) 34-7/8" (886mm)

19-5/8" (498mm)

10" (254mm)

9" (229mm)

NBV/NDV4842I

48" (1219mm) 34-7/8" (886mm)

19-5/8" (498mm)

10" (254mm)

9" (229mm)

53-1/4"

47"

Framing

53-1/4"

(1353mm)

53-1/4"

(1194mm)

Electrical Access

(1353mm) (1353mm)

(1194mm)

G 1-1/2 in.

2-3/8 in.

Gas Line Access

34-1/2 in.

37"

53-1/4"

(1353mm)

1/2 in. (13 mm) min. appliance to combustibles

48 in. (1219 mm) maximum

G B

Alternative Gas Access

8 in.

D 1/2 in. (13 mm) min. appliance to combustibles

1-3/4 in.

15-3/4 in.

34 in.

C

A

11-5/8 in.

31-1/2 in.

33-1/2"

(991mm)

19-1/8 in.

23-1/2 in.

15-3/4 in.

36"

NBV/NDV3933I

34-1/2 in.

19-1/8 in.

Access

Clearances (914mm)

34-1/2 in.

Electrical Electrical Access

8 in.

1-1/2 in.

Gas Line Access

NBV/NDV3630I

C

Alternative Alternative Gas Access

A

1-1/2 in.

B

3 in.

A

Top

Back

11-5/8in.

11-5/8in.

Model

Side

15-3/4 in.

(1016mm) (1092mm) (1245mm)

1 in. (25 mm) min. pipe to combustibles

D*

D

A Rear vent One 45° elbow Horiz Term

Top Vent One 90° elbow Horiz Term

In addition to these framing dimensions, also reference the following sections of the install manual: • Clearances and Mantel Projections (Sections 3.C. and 3.D.) • Vent Clearances and Framing (Section 6)

Rear Vent One 90° elbow Vert Term A

No elbows Horiz Term

Rear Vent Two 90° elbows Horiz Term

A

B

A

E

F C

1 in. (25 mm) min. pipe to combustibles

C A F

E

* For B-Vent pipe clearance dimensions, please refer to pipe manufactures installation specifications.

The rough framing dimensions shown represent the distance from stud to stud only and do not take into consideration the addition of drywall. Please refer to installation instructions for complete specifications and drawings when installing this product. Go to heatilator.com to download.

Limited Lifetime Warranty*

Available From

The strongest in the industry, Heatilator provides a limited lifetime warranty on gas-burning products of the most important aspects: firebox and heat exchanger.

a brand of Hearth & Home Technologies® 1915 West Saunders Street Mt. Pleasant, Iowa 52641 800-927-6841 | heatilator.com facebook.com/Heatilator twitter.com/Heatilator

*For full warranty details go to heatilator.com. The information provided in this literature is for planning purposes only and subject to change. Please consult the installation manual for actual installation. Actual product appearance may differ from product images. Fireplace glass and other surfaces get extremely HOT and can cause severe burns if touched. Do not remove the protective safety screen from the front of the glass. Keep a safe distance away. To learn more visit: www.heatilator.com/fireplacesafety.

youtube.com/HeatilatorFireplaces HTL-1009U-0813

B