179 Advances in Natural and Applied Sciences, 7(2): 179-185, 2013 ISSN 1995-0772 This is a refereed journal and all articles are professionally screened and reviewed

ORIGINAL ARTICLE Evaluation of Capacitor Sensor Performancein Reinforced Concrete for Corrosion Monitoring 1

Siti Fatimah Abdul Rahman, 1Mohammad Ismail, 1Norhazilan Md. Noor, 2Hazri Bakhtiar, Nordin Yahaya and 1Ahmad Safuan A. Rashid

1

1 2

Faculty of Civil Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor, Malaysia Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor, Malaysia Siti Fatimah Abdul Rahman, Mohammad Ismail, Norhazilan Md. Noor, Hazri Bakhtiar, Nordin Yahaya and Ahmad Safuan A. Rashid; Evaluation of Capacitor Sensor Performancein Reinforced Concrete for Corrosion Monitoring

ABSTRACT In this paper, a capacitor sensor was developed with intention to detect and evaluate corrosion activity in reinforced concrete slab sample. The performance of capacitor sensor was evaluated to determine the workability of the sensor in detecting impedance pattern when embedded in concrete structure. The diameter of impedance pattern can give the polarization resistance which is useful to calculate corrosion rate for future development. This was done by detecting the impedance Nyquist plot of concretesample. The capacitor sensor was tied to the reinforcement bar and the sample was immersed in 3.5% NaCl solution for seven days. The result shows that the capacitor sensor is fully functional in detecting impedance pattern. Hence, demonstrates potential capability of the sensor in measuring corrosion activity in concrete. Key words: Corrosion, Capacitor sensor, Impedance Introduction Monitoring corrosion activities in reinforced concrete structure can be carried out by using embedded sensors which is either built in the structure from the beginning or inserted later (Bungeyet al., 2006; Davis, 2000; Luca et al., 2004; Song and Sraswathy, 2007). Recently, researchers have embarked on continuous monitoring by embedding sensors in concrete. The use of fiber optic sensor for instance, yielded a good result for corrosion measurements, but the material itself is too brittle and difficult to work with (Ismail et al., 2009). Silver/silver chloride (Ag/AgCl) sensor and saturated calomel electrode (SCE) sensor are considered unsuitable for site purposes (Muralidharanet al., 2008). The galvanic sensor provide useful result in measuring corrosion rate, however, galvanic current cannot be detected when the resistance of the concrete is too high (Yoo, 2003). Exploring the potential of capacitor, a new sensor has been developed in this study. The development of the sensor is still in initial phase. Hence, this paper focuses on investigating the capability of this new capacitor sensor in detecting impedance pattern (Nyquist plot) in concrete structure under wet and dry condition. The findings may give greater opportunities to further develop the sensor into a fully working sensor capable of not just detecting the corrosion activity but measuring and evaluating the corrosion dynamic and severity on site. Materials and Method Capacitor sensor: A capacitor sensor was designed in circular shapeas depicted in Figure 1. It has a diameter and thickness of 11 mm and 1.6 mm respectively. The atomic percentages of sensor main compositional materials are copper; 60.23%, nickel; 18.42%, aurum; 12.15% and others 9.2%. The sensor was fabricated on a Flame Retardant 4 (FR-4) Printed Circuit Board (PCB) followed by nickel and gold coats on both front and back surfaces. Fig. 1 shows the design of embedded capacitor sensor, where, E= electrical source, a = radius plate A = 0.25 cm and b = radius plate B = 0.5 cm. Fig.2 (a) and (b) shows the microstructure image of capacitor sensor and EDX spectra at a particular energy (keV) using Field Emission Scanning Electron Microscopy (FESEM).

Corresponding Author: Norhazilan Md. Noor, Faculty of Civil Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor, Malaysia E-mail: [email protected]

180 Adv. in Nat. Appl. Sci., 7(2): 179-185, 2013

Performance of Capacitor Sensor in Concrete Environments by Impedance Method: The Nyquist plot was observed to evaluate the pattern to the conditions of reinforced concrete sample under wet and dry condition. For dry condition, the concrete specimen was dried and wetted in a room (T = 250C, 50% RH) for 2 days, 4 days and 7 days. Another batch of samples was immersed in NaCl solution for wet condition. The measurements for both conditions were carried out at 2nd, 4th and 7th days. An impedance method measurement was utilized to study the pattern of semicircle Nyquist plots as measured by the capacitor sensor. The measurement was then compared with the theoretical models. Fig.3 shows the example of theoretical model of impedance plane plot, also called the Nyquist plot. The perfect semicircle pattern reflects that the electrochemical system is at equivalent circuit. Based on the figure, the graph of imaginary impedance against real impedance was plotted as a function of frequencies of the alternate current (AC) source.Thus, the purpose of this test is to observe the impedance plane plot measured by the capacitor sensor so as to clarify that the circuit in the system is in the state of equilibrium regardless of the wet and dry condition. The test was conducted by finding the suitable frequencies range and then measuring the impedance of samples in dry and wet conditions.

Fig. 1: Outer plate (Plate A) and inner plate (Plate B) are separated by an insulating medium (dielectric) in sensor system.

Fig. 2: FESEM of capacitor sensor (a) microstructure image (b) EDX spectra.

181 Adv. in Nat. Appl. Sci., 7(2): 179-185, 2013

Fig. 3: Nyquist plotfor the equivalent circuit using SRI-CMIII (Andrade and Alonso, 1995). Results and Discussion Impedance Response of Specimen at Different Frequencies Range: The reinforced concrete sample with embedded sensor was used to determine the suitable range of frequencies to measure corrosion activity. The samples were prepared totally wet by leaving the samples in water tank and only recovered after 28 days of curing. The tests were divided into three sets of a particular range of frequencies which are 10Hz to 10 mHz, 10Hz to 1 mHz, and 10Hz to 0.1 mHz. Fig.4 shows the impedance pattern measured by capacitor sensor using the corrosion meter. The observation exhibits that there are semicircle plane plots for all three ranges of frequencies. However the semicircle plane plots ranged differently to each other because they were respectively influenced by the amount of measuring point. It was found that for range of 10Hz to 10 mHz in Fig.4 (a), there are 13 nodes of measurement, which almost completes a semicircle plane plot. As forthe second range (10Hz to 1 mHz), the semicircle was only noticeable around 10Hz to 56.2 mHz (refer to Fig.4 (b)). While for third range of 10Hz to 0.1 mHz as shown in Fig.4 (c), the semicircle plane plot was found around 10Hz to 0.316 mHz. By considering the total time for data collection, it can be concluded that the frequencies range for the third set (10Hz to 0.1 mHz) is inappropriate because the time taken to finish the measurement (at one position of sensor) was about 8 hours. Given the time constraint, this range is deemed not suitable. Furthermore, the finding for second set (10Hz to 1 mHz) shows that there are 17 nodes of frequencies. However, the nodes of measurement from 56.1 mHz to 0.1 mHz were not located around the semicircle plane plot. Meanwhile, the semicircle plane plot had a smaller diameter compared to the first set (10Hz to 10 mHz). Although a higher number of nodes in the Nyquist plot would be better, the low frequency problems due to the low corrosion rate influences the measurement reading (PRCM, 2007). Therefore, with regard to the findings, the perfect frequencies range for the sensor is set around 10Hz to 10 mHz. Impedance Response of Specimen in Wet and Dry Conditions: The Nyquist plot for dry conditions is shown in Fig.5.The Nyquist plots for 2 days and 4 days of drying duration as shown in Fig.5(a) and (b) are quite similar to the wet condition in Fig.6 (a) and (b). The samples intended for dry condition is believed not fully dried within 4 days of exposure to room temperature. However, after 7 days, the sample has achieved total dry condition and consequently no semicircle plot produced as shown in Fig.6 (c). This reflectsthe nonworking condition of the sensor due to incomplete equivalent circuit of Nyquist plot. For wet condition in Fig.6 (c), the semicircle plane plot was found in the system as expected, indicates the potential of corrosion due to the presence of water. Theoretically, in wet conditions, the ions/electrons are free to move and therefore the applied current can effectively works in order to measure the impedance. This pattern is related to the theoretical model of semicircle Nyquist plot as depicted in Fig.3 Conclusion: The embedded capacitor sensor is functional in detecting Nyquist plot pattern according to the findings. The findings do not indicate the capability of the sensor in measuring the corrosion rate, yet this preliminary study is important to assure that the capacitor sensor can yield Nyquist plot whereby the diameter of Nyquist plot can give the polarization resistance. This beneficial measurement can be used to calculate corrosion rate provided

182 Adv. in Nat. Appl. Sci., 7(2): 179-185, 2013

that the sensor is fully developed into corrosion monitoring tool. To conclude, the capacitor sensor functions properly in wet sample as shown by Nyquist plot. However, the equivalent circuit is not achievable in dry concrete. The overall finding shows that the capacitor sensor has great potential to be fully developed as a corrosion monitoring tool. The sensor is capable of detecting changes in the immediate vicinity of the steel for corrosion monitoring purposes.

Fig. 4: Nyquist plots of capacitor sensor (a)10Hz to 10 mHz (b) 10Hz to 1 mHz (c) 10Hz to 0.1 mHz.

183 Adv. in Nat. Appl. Sci., 7(2): 179-185, 2013

Fig. 5: Nyquist plots in different durations for dry conditions (a) 2 days (b) 4 days (c) 7 days.

184 Adv. in Nat. Appl. Sci., 7(2): 179-185, 2013

Fig. 6: Nyquist plots in different durations for wet conditions (a) 2 days (b) 4 days (c) 7 days. Acknowledgment The authors gratefully acknowledge the support for this research from MOSTI, Ministry of Science, Technology and Innovation, Malaysia, Research Management Centre UTM, and Faculty of Civil Engineering, Universiti Teknologi Malaysia (UTM).

185 Adv. in Nat. Appl. Sci., 7(2): 179-185, 2013

References Andrade, C. and C. Alonso, 1995. Corrosion Rate Monitoring in the Laboratory and On-site.Construction and Building Materials, 10(5): 315-328. Bungey, John H., Millard, G. Stephen and Grantham, G. Michael, 2006. Testing of Concrete in Structures. 4th Ed. Madison Ave, NY.: Taylor & Francis. Davis, J.R., 2000. Corrosion: Understanding the Basics. Materials Park,Ohio.: ASTM International. Ismail, M., E. Hamzah, C.G. Goh and I.A. Rahman, 2009. Corrosion Performance of Dual-Phase Steel Embedded in Concrete. The Arabian for Science and Engineering, 35(2B). Luca, B., B. Elsener, P. Pedeferri and R. Polder, 2004. Corrosion of Steel in Concrete: Prevention, Diagnosis, Repair. 2nd Ed. Weinheim: Wiley-VCH. Muralidharan, S., V. Sarawathy, A. Madhavamayandi, K. Thangavel and N. Palaniswamy, 2008. Evaluation of Embeddable Potential Sensor for Corrosion Monitoring in Concrete Structures. Electrochemical Acta, 53(24): 7248-7254. PRCM Portable Rebar Corrosion Meter SRI-CMIII Operation Manual, Shikoku Research Institute INC. (2007). Song, H.W. and V. Sraswathy, 2007. Corrosion Monitoring of Reinforced Concreet Structure – A review. International Journal of Electrochemical Science, 2: 1-28. Yoo, J.H., Z.T. Park, J.G. Kim and L. Chung, 2003. Development of a Galvanic Sensor System for Detecting the Corrosion Damage of the Steel Embedded in Concrete Structure: Part 1. Laboratory Tests to Correlate Galvanic Current with Actual Damage. Cement and Concrete Research, 33: 2057-2062.