This document is a practical guide for Tango ATK programmers and includes ...
Before going through the trails and examples, the Tango ATK architecture and ...
4: Configuration Using Web. Manager. Details using the Web Manager to set
parameters such as port and server properties. 5: Configuration via Telnet or
Serial.
UDS1100 Device Server User Guide. 3. Revision History. Date. Rev. Comments.
February 2006. A. Initial document. June 2006. B. Changes to operating and ...
OSSIM Users Guide. Version 1.6.5. Open Source Software Image Map – OSSIM,
pronounced “Awesome”. Document version 1.1. July 10 , 2006. Written by.
discusses how the Abstract Pattern can be applied to Devices to implement ... First make sure you have identified which abstract class your device belongs to. ... Future versions of the abstract class could include code if it considered necessary. ..
may not be reprinted or resold for commercial purposes. www.eileenbeha.com.
TEACHERS' GUIDE. Tango: The Tale of an Island dog. TANGO. The Tale of an ...
Main features of the XPress-I/O device servers and the applications for which
they are suited. 3: Installation. Instructions for getting the XPress-I/O device server
.
Shows the XPort Pro status as Online, Offline, Unreachable (if the. XPort Pro .... settings, and send an email. 121 ....
May 5, 2016 - Ethernet: 10/100 megabits per second (Mbps) ..... Lantronix DeviceInstaller application is a free utility program ..... hostname, and domain.
May 5, 2016 - Instructions for using the web interface to configure line and tunnel settings. Chapter ...... of the page
Unix operating system -- the Sun-OS, the HP-UX, and the DEC-Unix operating systems. The point-and-click interface is used as a driver program for a variety of ...
... SFB762), Ministry of. Education of Czech Republic (MSM0021620834), the Grant Agency of the Czech ... J. Padilla and David Vanderbilt, Surf. Sci. 418, 64 ... D. Lebeugle, A. Mougin, M. Viret, D. Colson, and L. Ranno, Phys. Rev. Lett. 103,.
Taylor, Amanda Timoney, Caroline Trent, and Renee Varnas. Choreographed by
: Jennifer Small. For the Love of Tango. “Tango to Evora” by Conjunto Berretin.
May 11, 2014 - ceptive methods in referent to urban health centers in Hamadan city, Iran. ... vaginal pathogens, high indices of infection by bacterial vaginosis ...
with a SIP-based conference phone and a regular SIP phone. ... conference phone to place a call to Carol with whom they are supposed ..... a=app:dda mbus.
ment, the experimental results and the comparison with the model are described in ... means of a dedicated utility which examines the SDDS file and maps the ...
Sep 1, 1996 - IDIOT program that has been included and a utility for separating ..... "rHit!n.o -ldl. Make sure that the praudit command in in the execution path.
Dec 20, 1996 - DART: purely eager training. Constructs and returns a complete cover tree to be used for prediction. ANS & AVE: use the cover tree produced ...
were classified as low, moderate, or high, for example, it would be more costly to
misclassify a high-risk ... Category of level of schooling attained ... In the Open
Data File dialog, navigate to the SPM Sample Data directory and then select the.
Exposure to Radio Frequency Signals . . . 2 .1. Specific Absorption Rate Data . . . .
. . . . . 2 .2 ... SIM Card Care . ..... or in areas posted: “Turn off two-way radio .” ......
9 XYZ. Options. Clear. 123. New. 145. You can reach me at 111-222-3
Overview. TextSpeak™ TS-04-NK is a text-to-speech speaker that generates a
clear and crisp synthesized voice. Data is sent to the speaker from common USB
...
fx-5800P. User's Guide http://world.casio.com/edu/. RJA516644-001V01. E ... In
no event shall CASIO Computer Co., Ltd. be liable to anyone for special, ...
Implemented in C++ - CVS repository: tango-ds ... partition. Partition_bit_2.
Tango::DEV_SHORT. Bit number of the second relay associated with the partition
.
TANGO Device Server
Pss zone device server User’s Guide PssZone Class Revision: - Author: michel_peru Implemented in C++ - CVS repository: tango-ds
Introduction: This is the device server dedicated to the control of the PSS zones of the machine.
Class Inheritance: Tango::Device_4Impl PssZone
Properties:
Device Properties Property name
Property type
Description
Daresbury_device_name
Tango::DEV_STRING
Device name of the associated Daresbury device server.
Ctrl_access_relay_devname_1
Tango::DEV_STRING
Device name of the first "controlled access" relay.
Ctrl_access_relay_devname_2
Tango::DEV_STRING
Device name of the second "controlled access" relay.
Init_search_relay_devname_1
Tango::DEV_STRING
Device name of the first "init search" relay.
Init_search_relay_devname_2
Tango::DEV_STRING
Device name of the second "init search" relay.
Search_in_progress_module
Tango::DEV_SHORT
Module number of the "search in progress" relay.
Search_in_progress_bit
Tango::DEV_SHORT
Bit number of the "search in progress" relay.
Search_complete_module
Tango::DEV_SHORT
Module number of the "search complete" relay.
Search_complete_bit
Tango::DEV_SHORT
Bit number of the "search complete" relay.
Ctrl_access_module
Tango::DEV_SHORT
Module number of the "controlled access" relay.
Ctrl_access_bit
Tango::DEV_SHORT
Bit number of the "controlled access" relay.
Itlk_net_dir_name
Tango::DEV_STRING
Name of the directory where is located the interlock network file.
Itlk_net_file_name
Tango::DEV_STRING
Name of the interlock network file.
Partition_daresbury_devname_1 Tango::DEV_STRING
Device name of the first associated Daresbury equipment.
Partition_daresbury_devname_2 Tango::DEV_STRING
Device name of the second associated Daresbury equipment.
Partition_module_1
Tango::DEV_SHORT
Module number of the first relay associated with the partition.
Partition_module_2
Tango::DEV_SHORT
Module number of the second relay associated with the partition.
Partition_bit_1
Tango::DEV_SHORT
Bit number of the first relay associated with the partition.
Partition_bit_2
Tango::DEV_SHORT
Bit number of the second relay associated with the partition.
Door_daresbury_devname_1
Tango::DEV_STRING
Name of the first associated Daresbury device.
Door_daresbury_devname_2
Tango::DEV_STRING
Name of the second associated Daresbury device.
Door_module_1
Tango::DEV_SHORT
Module number of the relay associated to the first door.
Door_module_2
Tango::DEV_SHORT
Module number of the relay associated to the second door.
Door_bit_1
Tango::DEV_SHORT
Bit number of the relay associated to the first door.
Door_bit_2
Tango::DEV_SHORT
Bit number of the relay associated to the second door.
Device Properties Default Values: Property Name
Default Values
Daresbury_device_name
No default value
Ctrl_access_relay_devname_1
No default value
Ctrl_access_relay_devname_2
No default value
Init_search_relay_devname_1
No default value
Init_search_relay_devname_2
No default value
Search_in_progress_module
No default value
Search_in_progress_bit
No default value
Search_complete_module
No default value
Search_complete_bit
No default value
Ctrl_access_module
No default value
Ctrl_access_bit
No default value
Itlk_net_dir_name
No default value
Itlk_net_file_name
No default value
Partition_daresbury_devname_1
No default value
Partition_daresbury_devname_2
No default value
Partition_module_1
No default value
Partition_module_2
No default value
Partition_bit_1
No default value
Partition_bit_2
No default value
Door_daresbury_devname_1
No default value
Door_daresbury_devname_2
No default value
Door_module_1
No default value
Door_module_2
No default value
Door_bit_1
No default value
Door_bit_2
No default value There is no Class properties.
States: States Names
Descriptions
ON
Normal state when everything is OK.
FAULT
This state is set in case of a problem with the Daresbury system.
ALARM
This state is set in case of a problem with one of the command relays.
Attributes: Scalar Attributes Attribute name
Data Type
R/W Type
Expert
Pss_access_state
DEV_SHORT
READ
No
Partition_state
DEV_SHORT
READ
No
Door1_state
DEV_SHORT
READ
No
Door2_state
DEV_SHORT
READ
No
Commands: More Details on commands....
Device Commands for Operator Level Command name
Argument In
Argument Out
Init
DEV_VOID
DEV_VOID
State
DEV_VOID
DEV_STATE
Status
DEV_VOID
CONST_DEV_STRING
Init_search
DEV_VOID
DEV_VOID
Enter_ctrl_access
DEV_VOID
DEV_VOID
Leave_ctrl_access
DEV_VOID
DEV_VOID
Get_itlk_net_dir_name
DEV_VOID
DEV_STRING
Get_itlk_net_file_name
DEV_VOID
DEV_STRING
Reset
DEV_VOID
DEV_VOID
1 - Init Description: This commands re-initialise a device keeping the same network connection. After an Init command executed on a device, it is not necessary for client to re-connect to the device. This command first calls the device delete_device() method and then execute its init_device() method. For C++ device server, all the memory allocated in the nit_device() method must be freed in the delete_device() method. The language device desctructor automatically calls the delete_device() method. Argin: DEV_VOID : none. Argout: DEV_VOID : none. Command allowed for: Tango::ON Tango::FAULT Tango::ALARM
2 - State Description: This command gets the device state (stored in its device_state data member) and returns it to the caller. Argin: DEV_VOID : none. Argout:
DEV_STATE : State Code Command allowed for: Tango::ON Tango::FAULT Tango::ALARM
3 - Status Description: This command gets the device status (stored in its device_status data member) and returns it to the caller. Argin: DEV_VOID : none. Argout: CONST_DEV_STRING : Status description Command allowed for: Tango::ON Tango::FAULT Tango::ALARM
4 - Init_search Description: This command sets the PSS to the "search" mode. Argin: DEV_VOID : Argout: DEV_VOID : Command allowed for: Tango::ON Tango::FAULT Tango::ALARM
5 - Enter_ctrl_access Description: Enter the "controlled access" mode of the PSS. Argin: DEV_VOID :
6 - Leave_ctrl_access Description: Leave the "controlled access" mode of the PSS. Argin: DEV_VOID : Argout: DEV_VOID : Command allowed for: Tango::ON Tango::FAULT Tango::ALARM
7 - Get_itlk_net_dir_name Description: This command returns the name of the directory where is located the interlock network file. Argin: DEV_VOID : Argout: DEV_STRING : Name of the directory where is located the interlock network file. Command allowed for: Tango::ON Tango::FAULT Tango::ALARM
8 - Get_itlk_net_file_name Description: This command returns the file name of the interlock network file. Argin: DEV_VOID :
Argout: DEV_STRING : Name of the interlock network file. Command allowed for: Tango::ON Tango::FAULT Tango::ALARM