Utility Conductor/ Wire Identification Guide - We

144 downloads 5254 Views 842KB Size Report
Utility Conductor/Wire. Identification Guide. For more information or to report recovered material. We Energies Corporate Security Office. 414-221-4024 ( during ...
For more information or to report recovered material

We Energies Corporate Security Office



Central Alarm Station



414-221-4024 (during normal business hours) 414-221-4120 (after business hours)

Utility Conductor/Wire Identification Guide

Utility Conductor/Wire Identification Guide

Trim cover insert to 9&3/8” x 11” Spine 1” x 11”

Utility Conductor/Wire Identification Guide TABLE OF CONTENTS Section 1

Aluminum Wire

Section 2

Copper Wire

Section 3

Miscellaneous

GLOSSARY Acronyms ACSR. Aluminum Conductor Steel Reinforced AWG (American Wire Gauge). Standard measurement used to determine diameter CN/JKT. Copper w/ nylon jacket insulation HD. Wire was “hard drawn” during processing SD. Wire was “soft drawn” during processing XLPE. Cross linked polyethylene insulated

Other Terms Aluminum Phase. High strength alloy Bare. Wire does not have an insulating cover Coated. Wire has an insulating cover. Electrical Current capacity. Designated by volts, i.e. 600v Lot Number. Specific part number for ordering from manufacturer Multiple cable assemblies. Designated by number and type of cable, i. e, 2 - #1/0, w/#2/0 neutral. Resistance. Designated by KCM value (350, 336.4, 750, etc.) Strands. The number of individual wires used in the cable. Width of multi-strand conductor. Designated smallest to largest: #1/0, #2/0, #3/0 and #4/0.

For more information or to report recovered material

We Energies Corporate Security Office 414-221-4024 (during normal business hours) Central Alarm Station 414-221-4120 (after business hours)



Issued September 2007/Rev. 04-09

Lot #101-8850

#6 AWG 7 Strand Aluminum Coated

#6 AWG 7 Strand Aluminum Coated

Lot #103-3441



#2 6/1 Strand ACSR Bare Aluminum

Lot #102-0978

300V 2 4/O XLPE Aluminum 1 246.9 Aluminum Bare

300V 2 4/O XLPE Aluminum 1 246.9 Aluminum Bare

Lot #102-1885

600V DB 2-350 Aluminum Phase w/ #3/O Neutral

600V DB 2-350 Aluminum Phase w/ #3/O Neutral

Lot #102-0706

600V DB 3-#3/O Aluminum Phase w/ 1/O Neutral

Lot #101-9872

300V 2-1/O XLPE Aluminum and 1-123.3 Aluminum Bare

300V 2-1/O XLPE Aluminum and 1-123.3 Aluminum Bare

Lot #102-3870

600V DB 3-750 Aluminum Phase w/ 350 Neutral

600V DB 3-750 Aluminum Phase with 350 Neutral

Lot #103-5118

336.4 KCM 26/7 Strand ACSR Bare Aluminum

Lot #102-0013

600V DB 2 - #1/O 19 Strand Aluminum Phase CD

Lot #103-4308

#3/O 6/1 Strand ACSR Bare Aluminum

Lot #102-0587

600V DB 2- #3/O Aluminum Phase w/ 1/O Neutral

Lot #101-9813

300V, 2 -#1/O Strand Aluminum Insulated with Bare Neutral

300V 2-#1/O Strand Aluminum Insulated with Bare Neutral

Lot #102-3811

600V DB (3) 750 KCM-61 Strand Aluminum Phase

Lot #101-9640

CN/JKT 15KV #2 Solid Aluminum Core

CN/JKT 15KV #2 Solid Aluminum Core

Lot #101-9690

CN/JKT 15KV #2 Solid Aluminum

CN/JKT 15KV #2 Solid Aluminum

Lot #103-3239

#4 7 Strand Copper 600 V X-Linked Poly

Lot #103-3964

#1/0 19 Strand Copper 600 V XLPE

Lot #103-2712

#6 SD Solid Copper WR Poly - Pole Grounds

Lot #103-4171

#4/O 19 Strand Copper 600V XLPE

Lot #103-3891

1/0 7 Strand 3D Copper Non Coated BW

Lot #103-3859

#1/O 19 Strand Tinned Copper Coated Bonding

Lot #103-2755

#6 HD Solid Copper WR Poly - Pole Ground

Lot #103-4405

#4/O 7 Strand SD Copper Non Coated BW

Lot #101-2924

15KV #2 Stranded Copper

Lot #101-9920

600V 500 KCMIL 37 Strand

Lot #101-3874

14KV Paper Insulated - Lead Covered

Lot #103-4405

#4/0 Stranded Copper

Lot #103-3891

#1/0 7 Strand Copper Steel Core

Lot #101-0475

Telephone 6 Pair

Lot #101-0480

Cable TV (Coax)

Lot #103-3280

#2 7-Strand, CU 600V XLPE

Lot #103-5266

350 KCM 37 Strand CU 600V XLPE

Lot #101-5295

500 KCMIL 28KV Copper

2” Copper Buss

4/O Bare Copper Ground

Lot #155-1302

Copper Ground Rod - Steel Core

Lot #103-0493

7 Strand Steel Guy Wire

#4/0 Copper Temporary Station Ground