To learn more, scan the code with your smartphone, or visit heatilator.com. Novus
direct vent & b-vent gas fireplaces. Traditional Style, Proven Value. The Novus ...
Novus direct vent & b-vent gas fireplaces
Novus direct vent & b-vent gas fireplaces
Cover: Novus shown with optional demi front in bronze, traditional refractory, plymouth mantel and absolute black granite. Above: Novus shown with plymouth mantel and absolute black granite.
Traditional Style, Proven Value The Novus is the best-selling gas fireplace of all time. Why? Stylish design elements and robust fires—paired with the proven value and dependability of Heatilator. Glowing embers, realistic logs and endless finishing options add character to any space. Trust in the industry’s most recognized brand. The Novus will deliver. Features • 30", 33", 36" or 42" viewing areas • Many installation possibilities including tight spaces and corners • Make it your own with multiple fronts, finishes and traditional or herringbone panels
IntelliFireTM Ignition System
Direct Vent Technology
The IntelliFire™ Ignition System (IPI) is an advanced intermittent
Direct Vent fireplaces remove 100% of combustion exhaust and odors
pilot ignition system. IPI constantly monitors ignition, ensures safe
outside of the home. These sealed fireplaces provide optimal heat,
functioning and conserves up to $10/month in energy costs.
conserve energy and ensure clean, safe indoor air quality.
To learn more, scan the code with your smartphone, or visit heatilator.com.
To learn more, scan the code with your smartphone, or visit heatilator.com.
Options Fronts
Front Finishes
Refractory
Finish options shown available for the optional Demi front.
Black
Bronze
Traditional Refractory
Demi Non-Operable Front
Controls TotalRemote This remote control effortlessly manages heat output
SmartRemote An added level of function and convenience in a
and comfort level. For fireplaces and inserts.
remote control. For fireplaces, stoves, inserts, and gas logs with or without line power.
Models: RCT-MLT-HTL
Models: SMARTBATTHTL-B, SMART-STAT-HTL
Features: Hardwired Receiver, Timer Mode, Thermostat Mode,
Features: Battery-Powered or Hardwired Receiver, Timer Mode,
Room Temperature Readout, Flame High/Low, Fan Speed, On/Off
Thermostat Mode, Room Temperature Readout, On/Off
IntelliSwitch200 This wall switch is designed exclusively for Heatilator fireplaces with the IntelliFire ignition system. Models: WSK200-HTL Features: On/Off, Auto Battery Backup, Battery Strength Indicator, Pilot Activation, Fan Speed
Additional Options Not Pictured • •
Fan Kit Outside Air Kit (for B-vent models only)
• •
Venting Gas Conversion Kits Mantels and Surrounds
• •
Direct Vent: DVP pipe B-Vent: 5" B-vent pipe
Models* Available Model
BTU/HR Input(NG)
Opening Size
NBV/NDV3630I
14,000 - 20,000
30" (762mm)
NBV/NDV3933I
15,000 - 22,000
33" (838mm)
NBV/NDV4236I
17,000 - 25,000
36" (914mm)
NBV/NDV4842I
20,500 - 30,000
42" (1067mm)
U.S. Efficiencies Steady State - Since most homeowners use their fireplaces for an extended time while they are in the room, Steady State measures how efficiently your fireplace converts fuel to heat once it is warmed up and running in a “steady state”.
Rating
NDV3630
NDV3933
NDV4236
NDV4842
Steady State
75%
78%
73%
77%
AFUE
52%
48%
52%
56%
Rating
NDV3630
NDV3933
NDV4236
NDV4842
55%
51%
54%
58%
AFUE - AFUE rating is more typically used with appliances, like your furnace, that continually cycle on and off to maintain a constant temperature.
Canada Efficiencies EnerGuide (CSA P.4.1-02) - EnerGuide is a rating used in Canada to measure annual fireplace efficiency.
EnerGuide
(CSA P.4.1-02)
Value | Dependability | Most Recognized Brand
Technical Specifications Model
Front width (A)
Back width (C)
Height
Depth
Glass size (b)
NBV/NDV3630I
35" (889mm)
8-5/8" (219mm)
34" (864mm)
19-1/8" (486mm)
30"w x 22-5/8"h
NBV/NDV3933I C
C 38" (965mm)
11-5/8" (279mm)
34" (864mm)
19-1/8" (486mm)
33"w x 22-5/8"h
NBV/NDV4236I
41" (1041mm)
14-5/8" (371mm)
34" (864mm)
19-1/8" (486mm)
36"w x 22-5/8"h
34" (864mm)
19-1/8" (486mm)
42"w x 22-5/8"h
C
C
19-1/8 in.
NBV/NDV4842I
19-1/8 in.
11-5/8in. 11-5/8in. Left Side
A
47" (1194mm)
Front
A
23-1/2 in.
11-5/8 11-5/8 in. in.Right
A A
C 31-1/2 in.
31-1/2 in. 2-3/8 in.
34 in.
19-1/8 in.
6-1/2 in.
20-5/8"23-1/2 (508mm) in.
C
Gas Line
Gas Line Access Access
6-1/2 in.
19-1/8 in.
19-1/8 in.
2-3/8 in.
34 in.
B
3 in.
A
Gas Access
8 in.
6-1/2B in.
1-3/4 in.
3 in.
D
B
F
(498mm)
(1102mm)
(1194mm)
39"
35-1/2"
19-5/8"
43-3/8"
47"
42"
37-5/8"
19-5/8"
41-7/8"
19-5/8"
NBV/NDV4236I
(1067mm)
NBV/NDV4842I
(1219mm)
48"
(902mm) (956mm)
(1064mm)
(498mm) (498mm) (498mm)
43-3/8"
E
19-5/8"
(851mm)
(1102mm)
43-3/8"
(1102mm)
43-3/8"
(1102mm)
B
C
A
Drywall
47"
(1194mm)
47"
Alcove Installation
A
Model
A
B
c
d
6-1/2 in.
Rough Opening 1-3/4 in. (width)
Rough Opening (height)
Rough Opening (depth)
Rough Opening (dvp pipe)
3 in.
D
Rough Opening (slp pipe)
(940mm)
40"
NBV/NDV3630I
36" (914mm)
34-7/8" (886mm)
19-5/8" (498mm)
10" (254mm)
9" (229mm)
43"
NBV/NDV3933I
39" (991mm)
34-7/8" (886mm)
19-5/8" (498mm)
10" (254mm)
9" (229mm)
49"
NBV/NDV4236I
42" (1067mm) 34-7/8" (886mm)
19-5/8" (498mm)
10" (254mm)
9" (229mm)
NBV/NDV4842I
48" (1219mm) 34-7/8" (886mm)
19-5/8" (498mm)
10" (254mm)
9" (229mm)
53-1/4"
47"
Framing
53-1/4"
(1353mm)
53-1/4"
(1194mm)
Electrical Access
(1353mm) (1353mm)
(1194mm)
G 1-1/2 in.
2-3/8 in.
Gas Line Access
34-1/2 in.
37"
53-1/4"
(1353mm)
1/2 in. (13 mm) min. appliance to combustibles
48 in. (1219 mm) maximum
G B
Alternative Gas Access
8 in.
D 1/2 in. (13 mm) min. appliance to combustibles
1-3/4 in.
15-3/4 in.
34 in.
C
A
11-5/8 in.
31-1/2 in.
33-1/2"
(991mm)
19-1/8 in.
23-1/2 in.
15-3/4 in.
36"
NBV/NDV3933I
34-1/2 in.
19-1/8 in.
Access
Clearances (914mm)
34-1/2 in.
Electrical Electrical Access
8 in.
1-1/2 in.
Gas Line Access
NBV/NDV3630I
C
Alternative Alternative Gas Access
A
1-1/2 in.
B
3 in.
A
Top
Back
11-5/8in.
11-5/8in.
Model
Side
15-3/4 in.
(1016mm) (1092mm) (1245mm)
1 in. (25 mm) min. pipe to combustibles
D*
D
A Rear vent One 45° elbow Horiz Term
Top Vent One 90° elbow Horiz Term
In addition to these framing dimensions, also reference the following sections of the install manual: • Clearances and Mantel Projections (Sections 3.C. and 3.D.) • Vent Clearances and Framing (Section 6)
Rear Vent One 90° elbow Vert Term A
No elbows Horiz Term
Rear Vent Two 90° elbows Horiz Term
A
B
A
E
F C
1 in. (25 mm) min. pipe to combustibles
C A F
E
* For B-Vent pipe clearance dimensions, please refer to pipe manufactures installation specifications.
The rough framing dimensions shown represent the distance from stud to stud only and do not take into consideration the addition of drywall. Please refer to installation instructions for complete specifications and drawings when installing this product. Go to heatilator.com to download.
Limited Lifetime Warranty*
Available From
The strongest in the industry, Heatilator provides a limited lifetime warranty on gas-burning products of the most important aspects: firebox and heat exchanger.
a brand of Hearth & Home Technologies® 1915 West Saunders Street Mt. Pleasant, Iowa 52641 800-927-6841 | heatilator.com facebook.com/Heatilator twitter.com/Heatilator
*For full warranty details go to heatilator.com. The information provided in this literature is for planning purposes only and subject to change. Please consult the installation manual for actual installation. Actual product appearance may differ from product images. Fireplace glass and other surfaces get extremely HOT and can cause severe burns if touched. Do not remove the protective safety screen from the front of the glass. Keep a safe distance away. To learn more visit: www.heatilator.com/fireplacesafety.
youtube.com/HeatilatorFireplaces HTL-1009U-0813
B